T12N R3W SEC 15 LT 127
c 15 LoS 127 #015-482-02 Municipality of Anchorage On-Site Water and Wastewater Program • (907) 343-7904 Page of ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP161190 PID Number: 015482-02 Dwelling: ❑■ Single Family (SF) ❑ Duplex(D) ❑ Multiple(SF and/or D) Project: ❑■ New ❑ Upgrade Name: Andrew Newton & Raena Schraer ABSORPTION FIELD Address ❑ Deep Trench ❑■ Shallow Trench ❑ Bed El Mound 10251 Elmore Road Anchorage, AK 99516 ❑ Other Phone Number of Bedrooms Soil Rating Total depth from original grade 440-1541 3 1 .2 GPD/SF 7.4 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade Gravel depth beneath pipe Subdivision Block Lot 3.4 Ft. 4 Ft. 127 Fill added above original grade Gravel length Township Range Section 0-.5 Ft. 38 Ft. 12N 3W 15 Gravel width Beds:Number of Lines Distance between lines SEPARATION DISTANCES 5 Ft. Ft. To Septic Absorption Lift Station Holding Sewer Total absorption area Number of trenches Dist.between trenches From Tank Field Tank Line 380 Ft2 1 Ft. Well >100' >100' NA NA >25' TANK 0 Septic 0 S.T.E.P. ❑ Holding ❑ Other Manufacturer Capacity >100' NA NA Anchorage Tank 1,000 Gal. Surface Water >100' Material Number of compartments Lot Line >5' 4' NA NA NA Steel Two Foundation >5' >10' NA NA LIFT STATION Manufacturer 'Capacity Curtain Drain None Noted Gal. Pump on level at Pump off level at High water alarm at Remarks in. in. in. Pump make and model Electrical Inspections performed by PIPE MATERIAL House to tank D3034 Tank to D3034 Installer drainfield Denali Excavating DrainfieldD3034 CO/MTD3034 Inspector MEA BENCH MARK (Assumed elevation) 100.0 ft Inspection gc 19/2/16d 9/2/16 Location and description dates: 2" 3'd 9/3/16 a'h Garage Slab COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL 40' +,�,,....:4..q t11 al. P.• ••6‘- --#* Conditional Approval: Date ��'• 'Co.. .11 ' • A %: :.. 9TH ;..�.. . .. e/ 1.I�, MICHAEL E. ANDERSON . o c' ' CE-4381 .�`�. Approved h, 1.6;.amigg Date - J 4 Inspection Report_9-1-12.doc Municipality of Anchorage Page 2 of 3 DEVEOPMENT SERVICES DEPARTMENT 4700 South Bragaw Street Anchorage, AK. 99519-6655 — 343-7904 Permit Number: 0SP161190 PID No. 015-482-02 BLM Lot 126 50.0' N 90'00'00"E 279.90' BLM Lot 127 , 46,200 s.f. A B BLM Lot 125 1 ,7 S1 47.5'37.9' Z S2 52.7'44.0' (1) • C4 34.3'38.1'; OM1 36.5'41.8' O C5 70.9'73.1' O OD X) \ GRAVEL _ Pi o DRIVEWAY co rri M1 THREE WELL CO CD C5E_ ® iC4 = BEDROOM ® can D W TFisSite _FCO HOUSE ALTERNATE SITE cA 'IAdontex Treatment S2 51 ® System with 9' Long x 5' Wide x 4' Effective \\ Depth Absorption `\ Trench. Application Rate 5 GPD/SF. N 90'00'00'W 279.86' i��muss>,,1, WIRE FENCE .-4•-,v__ OF A7 .��� LEGEND Air C');:'. �;IS/r 1�. Si — Septic Vent _ 9 TH — Test Hole ` 49th --J,--- \ ..* M1 — Monitor Tube BLM Lot 128 BLM Lot 130 1 • S C4 — Clean Out 2C0 — Double Clean Out 0 7o : � FCO — Foundation Clean Out ;MICHAEL E. ANDERSON t ..�• . No. CE-4381 :•� : PLAN AS BUIL T •♦14jAUFES���:4�••• SCALE 1' = 50' Municipality of Anchorage Page 3 of 3 DEVEOPMENT SERVICES DEPARTMENT 4700 South Bragaw Street Anchorage, AK. 99519-6655- 343-7904 On-Site Wastewater Disposal System or Well Inspection Report Permit Number: OSP161190 PID No. 015-482-02 99.3 IU (7) U CO Original & / _ Finished -, Grade 1,000 Gallon Septic Tank 95.95 g 8 U 2U 98.8 i - - Finished Grade Original Ground Geotextile Fabric 95.4 \ Drainfield Rock 95.4 90.4—/ 91.4-7 Ii 38'(Total Effective Trench Length) 81.8 j No Groundwater 9/15/15 ••••,OF „'%��• 0 ` 49th - •t 111;:1)44-4-Lei 1)44- it. ; PROFILE AS-BUILT MICHAEL E. ANDERSON 1 �,t�� No Scale I����'� .;i t-1 P•<< '•e Na"R0EESSX�•4•• Certified Drilling Log DOC CO dba 3ULLIVAN 8,« WATER WELLS le. P.O. Box 670269, Chugiak,AK 99567 688-2759 OWNER OF LAND: Andrew Newton Bore Hole Data ADDRESS: 10251 Elmore Road, Anchorage,AK 99507 Depth LEGAL DESCRIPTION T12N R3W SEC 15 LOT 127 From To DATE: 10-13-16 0 2 Casing Stickup PERMIT NUMBER: OSP161190 DATE OF ISSUE: 8-19-16 TAX IDENTIFICATION NUMBER 01548202000 2 4 Overburden Is well located at approved permit location: >lYes No 4 12 Silty Sand &Gravel w/Clay Method of Drilling: Mair ricable I (cable tool 12 49 Tight Silt Sand & Gravel Depth of Well: 221' 49 57 Silt&Sand Casing Type: Steel Wall thickness .250 inches 57 124 Tight Silty Sand &Gravel Diameter: 6 inches, depth 220 feet 124 132 Silt&Sand Liner type Static Water Level: 159 feet 132 164 Tight Silty Sand &Gravel Recovery Rate 30 gpm I I gph 164 177 Clay& Gravel Method of Testing Air 177 179 Tight Silt Sand & Gravel 2 GPM Well Intake Opening Type: Fl open end nopen hole n Screened Start feet Stopped 179 184 Clay&Gravel [1 Perforations Start feet Stopped 184 207 Silt&Sand w/Gravel 3 GPM Grout Type: Bentonite Volume: 50 lbs 207 221 Sand & Gravel Depth:from 2 feet,to 42 feet Well Disinfected Upon Completion: Flyes I I no Method of Disinfection: Chlorine 50 PPM Comments: WATER QUALITY TESTING Coliform r1►" Co1/100mL Nitrates t mg/t. Arsenic ug/L Drillers Name: Cole Sullivan ATTENTION: It is the responsibility of the property owner to submit a copy of the well log to the proper authority. Municipality of Anchorage: Department of Health & Human Services and/or Department of Environmental Conservation. MatSu Borough: Department of Environmental Conservation. Jun 13 17 09:48o Ancho•.aga Well&Pump Ser 9072430742 p p----/i, `I( '. 3443 -- 7q637 ✓ Development Services Deportment 4.1---7---\\ Building Safety Division jr,c,k "'eOn-5r a Water Wastewater Program 7r 4700 EImcre Road x -.P.D. Box 196650 4 ly Ma�*ueg'cr, Anciwrcge, AK 99507 Mayor www,Runa.orml.mis (907)243-79C4 Pump Installation Log Well Drilling Permit Number: SIN_.__ Date of issue _- r Parcel T.dei�titiration `umbar:.-__---- I r: `>G HAA C... Legit Description Property Owner Name Address: l 4 i R.ffr►i-o+.r- 1 10 2.-1 €G..rlvtio r r 1 l'>>mp Irmtallation Date: 7/e f s://7! 712A P: 30-)P: 30-) SCC f`) l Pump lntei:e Depth r3elu•.4 Top M Well Casing:2/0 feet Pomp Manufacturer's Mance: 3> ci<€7- Purnp Model: S51(, - Pump Sine N by Pittess Adapter Burial Depth: 'o tett Pities%Adapter Manufacturer's Nattie: . Yltic•ss.&dapt.r Installer: A/i A Well Disinfected C'pnr±Completion? `,7; ?fi n Method of Disinfection: " c /4e..-6--e-c: Comments: �x ..ate:...__ a__-•----�------� �-5-.n-Trfi�..�- �._ - —r �__ ./� r ;.,-.. ANCHORAGE WELL&PJMP SERI' Pump inaller Nance: r'T { i/- 330 EAsr7E" Ave+VUE �. ANCFOcriG:,AK 99518 PHONE•907-24i-0740 AY/PS.CCM • Attention: 'no 2u:np ins:alit: .,.hall provide a pump installation log to tl!e!)SD within 30 cats of pump ir.stallaiion. Municipality of Anchorage no,,arnncnt P.O. Box 196650 • 4700 Elmore Road Anchorage, Alaska 99519-6650 • (907) 343-7904 • Fax (907) 343-7997 http:llwww.muni.orglOnsite Development Services Division On-Site Water and Wastewater Program **** VARIANCE/WAIVER REVIEW * * ** Waiver#: OSV161108 CC)SA#: Permit#: OSP161190 PID#: 015-482-02 Legal Description: T12N R3W Sec 15 L127 Engineer: Anderson Engineering Applicant: Andrew Newton Your request for a waiver of the required 50 feet horizontal separation from the absorption field to the excessive slope has been approved. The approved separation distance is 20.0 feet. In addition, the field may be perpendicular to the contours. This waiver approval applies to the proposed absorption field only. Any future upgrade to the on-site wastewater disposal system will require all separation distances be met or another approval from this department. Add comments /explanations or DELETE n The affected adjacent property owner(s) ,have been given a 7 day notice regarding this waiver. Notarized letter(s) of nonobjection have been received from the owner(s) of the affected adjacent property. ® Adjacent properties are not affected by this waiver. Waiver is Granted: X Waiver is not Granted: Date: q106 06 Approved by: Name of Revievyef-- **** VARIANCE/WAIVER REVIEW **** Permit Number: Tax Code Number: Work Type: On-Site Wastewater Disposal System Permit OSP161190 01548202000 Septic MUNICIPALITY OF ANCHORAGE Development Services Department On-Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Initial Permit Effective Dates: August 19, 2016 to August 19,.2017 Design Engineer: ANDERSON ENGINEERING Subdivision: T12N R3W SEC 15 Site Legal Address: T12N R3W SEC 15 LT 127 G:2536 Owner/Address: SCHRAER RAENA & NEWTON ANDREW 5004 ROGER DR ANCHORAGE AK 995071339 Site Mailing Address: 10251 ELMORE RD, Anchorage Lot Size in Sq Ft: 46200 Total Bedrooms: 3 l)cl)a] tm(mt This permit is for the construction of: Y Disposal Field Y Septic Tank N Holding Tank N Privy N Private WelI N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October '~5 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. SpeciaI Provisions: 7 day groundwater monitoring required. Construction may proceed at your own risk before the monitoring is complete. Received By: Issued By: Date: Date: 9 ,~/L,/'~ IVIUNICIPALITY OF ANCHORAGE Community Development Department Phone: 907-343-7904 Development Services Division ~ Fax: 907-343-7997 On-Site Water & Wastewater Program ON-SITE SEWERANELL PERMIT APPLICATION Parcel I.D. 015-482-02 Property owner(s) Andrew Newton & Raena Schraer Mailing address 5004 Roger Drive Anchorage, AK 99518 Day phone 440-0541 Site address NHN Elmore Road Anchorage, AK 99516 Legal description (Sub'd., Block & Lot) Legal description (Township, Range & Section) Lot 127 T12N R3W Section 15 Lot 127 Lot Size 46,200 Sq. Ft. Number of Bedrooms Three APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: ([] all that apply) Absorption Field [] Initial [] Single Family (SF) [] (w/wo ADU) Septic Tank [] Upgrade [] Duplex (D) [] Holding Tank [] Renewal [] Multiple Dwellings [] Privy [] (SF and/or D) Private Well [] Water Storage [] THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: Absorption to Trench >25% Distance: 20' I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: Date of Payment: Receipt Number: Permit No. Waiver Fees: Date of Payment: Receipt Number: Waiver No. Permit App ...... c. ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766 (FAX) August31,2016 Municipality of Anchorage Development Services Department On-Site Water and Wastewater Program 4700 Elmore Road Anchorage, AK 99519-6650 Subject: T12N R3W Section 15 Lot 127 Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer: The owner of T12N R3W Section 15 Lot 127 intends to construct a new three-bedroom home on the lot. We are therefore requesting a permit be issued for the construction of a new well and septic system to accommodate the home. The attached Site Plan and backup documentation identify the location and configuration of the proposed well and septic system along with the alternate site. Also identified on the plans are the existing wells in the area and septic systems on surrounding lots. No conflicts exist between the proposed septic system and well or septic systems and wells on adjacent lots. Drainage arrows and ground surface contours are shown on the site plan showing the grade and direction of flow on the lot. The drainage pattern will not be changed as a result of this project. The test hole placed on the lot in the area of the absorption trench and alternate site indicate fill material composed of sandy gravel with silt (GM) to a depth of 12'. Original ground and a 6" organic layer was encountered at that level. The percolation rate of the soil was determined to be 2.9 minutes per inch. No groundwater was found during the placement of the test hole and the monitoring period is ongoing. The absorption trench will be placed in the clean fill placed on the lot more than two years ago. The fill is compacted and representative of in situ material. It is suitable for the treatment and disposal of septic effluent. An application rate of 1.2 gallons per day per square foot was used in the design of the absorption system. We are proposing to place a new 1,000-gallon septic tank and a 38' long by 5' wide by 4' effective depth absorption trenches to treat and dispose of the effluent generated in the house. The elevation of the distribution line in the absorption trench will be 3' below the surface and the total depth will be 7'. A minimum of 2" of T12N R3W Section 15 Lot 127 August 31, 2016 Page Two insulation and 2' of fill will be placed over the absorption trench and 4' over the septic tank. The ground surface on the lot in the area of the septic system is virtually flat. A slope exists to the south of the primary trench which exceeds 25% but is more than 20' away. The new trench will be constructed out of parallel with the contours of the slope but will remain in the absorptive soil delineated in the design. The new septic system will be constructed a minimum of 100' from all wells and any surface water and 10' the proposed and existing water services in the area. If the system is constructed in accordance with our design the following statements apply: The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, Michael E. Anderson, P.E. Attachments .-~ b~. ............. ;...~?~ ~. ..... ~ ...................... t Y12N RSW SECTION 15 i 102ND AV£NUE FRIGHT OF WAY / \ J 279/.95 / , , , , I ~ Sep{ic Area I 0 I I~ N 90'O0'O0"E / 27~93" I % ~ No conflicts 0/ ~dge of Slope / ~ .... / I with wells or IZ The water ma~r / I n Emore Road k Driveway x ~ , ~ IH2 TH3 does not % % Three ~earoom conflit with on ~2~ ~ x Home I ~ ~x ~ CO ~AIt. %FCOf ] ~ ~8: Long x 5' Wide x e ~ ..~ TH4 / ~ &%Effective Depth TH5 . 2, SV SV ~ / Ab~rpt[on Trenches 1,000 Gallon ~ ~ ~. Edge of Slop~ Septic Tank / ~ -// I I ALTERNATE SITE N 90'00'00'% / 279,93" I I Adontex Treatment / System with 9' Long x Depth Absorpt on 1 28 LLULI~U ~m. Trench. Application ~tic Vent I ~¢ OF ~/~ Rate 5 GPD/SF. TH - Test Hole . . ~ I ~ ~ ......... .,~ MT - Bani(or Tube ~;-" , '"~'~ No conflict with septic '~ CO - Clean Out I ~ F ~ '%~ system on this lot ~ 200 - Double Clean Out II ~-/ 49~h ~ ~ Ii ~ FCO- Foundation Clean Out I BLM LOT 27, SECTION 15 T12N R3W DESIGN FACTORS: SYSTEM REQUIREMENTS: Three Bedroom Home 5' Wide Trench System Perc. Rate: 1-5 Min./Inch 1,000 Gallon Septic Tank Application Rate: 1.2 GPD/SF 4' Drainfield Rock 3 Bedrooms X 150 GPD/1.2 GPD/SF (Application Rate) = 375 SF Absorption Area 375 SF/5 SF/LF*.5 (Red. Factor) = 37.5 LF Trench Length THEREFORE: Construct a 38' Long x 5' Wide x 4' Effective Depth Absorption Trench atthe Location Shown. Flow Line Elevation in Trench to be 3' Below Original Ground Surface. Total Depth to be 7' Below Existing Ground. Provide 4' Cover Over Septic Tank and 2' Cover and 2" Insulation Over Absorption Trench. Maintain 100' Separation from Wells in the Area. eII Natural Backfill 2" Insulation & Geotextile Fabric 4" Perforated PVC (Holes Down) Drainfield Rock TYPICAL DEEP TRENCH SECTION (NO SCALE) NOTE: Grade Area Over Trench to Drain Away. .'% ? · · , · ~ " 49th Minimum 6 Separabon From Bedrock. ~,,,,~...'...4......,..,...~...,-.,,,'~L...~ Minimum 4' Separation From Groundwater. ~ ,.,./~....~..~.~....._~..._.~.....~ Mlmmum 100 Separation From Wells in the Area. ~. ~ MICHAELE ANDERSON Minimum 100' Separation From Surface Water or Streams. ~\ No. c.4~a~ ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766 (FAX) August31,2016 Municipality of Anchorage Development Services Department On-Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: BLM Lot 127, T12N R3W Section 15 Absorption Trench to Slope Waiver Dear Onsite Services Engineer: The proposed absorption trench and alternate site on the subject lot is located 20' from a break in grade greater than 25%. We are therefore applying for a waiver allowing placement of the absorption trench and the alternate site at the designated sites shown on the Site Plan. The attached drawing shows the existing absorption trench in relation to the slope. The imaginary 25% slope when extended downward from 2.5' above the flow line daylights 38.5' from the edge of the trench. The soils in the trench are clean gravel with minor silt which will absorb water well. The majority of the absorption will be down with little or no migration toward the slope. We therefore request a waiver be issued allowing placement of the new absorption trench and alternate site at 20' from a slope greater than 25%. Michael E. Anderson, P.E. Z Z ©r-q z~zZ ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766 (FAX) August31,2016 Municipality of Anchorage Development Services Department On-Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: BLM Lot 127, T12N R3W, Section 15 Absorption Trench to Ground Contours Dear Onsite Services Engineer: The absorption trench on BLM Lot 127 must be constructed perpendicular to the contours of the ground surface. This is the most suitable area to place the new absorption trench due to the placement of the house and well on the lot. The surface slope in the area is approximately 2% to the west with no cross sloping. The absorption trench will be placed a total of 7' below ground at the east end and approximately 6.25' below ground at the west end. The organic layer in this area has been completely removed and compacted clean gravel fill has been placed on the lot. The distribution pipe in the absorption trench will be totally in the gravel absorptive layer. We therefore request a waiver be issued allowing placement of the new absorption trench to run perpendicular to the ground slope contours. Sincerely, Michael E. Anderson, P.E. 03 133 --i West II East &700 DEPTH (~et) I"~IJNICIPALITY OF ANCHORAGE DEVELOP~IENT SERVICES DEPARTPIENT E3RAGAW STREET ANCHORAGE, AK 99519 6650 SOILS LOG - PERCOLATION TEST LEGAL DESCRIPTION: BLN LOT 127 PERFORMED FOR: ANDY NEWTON DATE: 8/10/I/+PROJECT No.: PARCEL ID#: TECHNICIAN: [ TEST HOLE2 OB/OG SILTY SAND SM BOH 17' 2 3 4 5 6 7 8 9-- 10 11 12 13 14 15 16 18 19 20 A. ]~ARALA SLOPE · DATE OF MON TOPd~G:' C) / 15 / 15 ~ SITE PLAN DATE READING GROSS TINE NET T HE ~^~ATERI NET DROPDEPTH TO (PIlNUTES) (PIINUTES) (~I~CHES) (INCHES) TEST HOLE PRESOAKED PRIOR TO TESTING: 2 1:41 30 6.31 0.81 3 1:42 5.75 4 2:12 30 6.56 0.81 5 2:13 5.63 6 2:43 30 6.44 0.81 PERCOLATION RATE: 40 TEST RUN BETWEEN: 4 __(M[N/INCH) PERC. HOLE DIA. 6 .(INCHES) FT. and 5 FT. COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST. TEST PERFORMED BY ANDERSON ENGINEERING. I, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE: 8-16-16 4?OO .[ DEPTH (feet) 2 3 5 6 7 8 9 20, MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT BRAGAW STREET ANCHORAGE, AK 99519-6650 SOILS LOG - PERCOLATION TEST LEGAL DESCRIPTION: PARCEL ID~: o~/0G SITE PLAN DEPTH TO DATE READING GROSS TiNE NET TINE WATER NET DROF (MINUTES) (MINUTES) (INCHES) (INCHES) ~/~z/~, TEST HOLE PRESOAKED PRIOR TO TESTING: 2 ¢,lt q 30 q,¢? PERCOLATIONRATE:/~ (MIN/tNCH) PERC, HOLEDIA.~_(INCHES) TEST RUN BETWEEN ~ FT and ~' FT. 'OMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST_.~,'~?~ TEST PERFORMED BY ANDERSON ENGINEERING. 1, MICHAEL E, ANDERSON CERTIFY THAT TttlS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE: MUN~CIPALIYY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT ATO0 BRAGAW STREET ANCHORAGE, AK 9g$~c)~6650 SOILS LOG ~ PERCOLATION TEST LEGALDESCRIPTtON; t~-~,2t''~ ~7 PERFORMED }'QR', _~__~Sf/JwX~$~Z' DXm ~/g~,~ ~ _ V~O~¢~No.: PARCEL ID#: TECHNICIAN: DE?~Ii {Feet) 1 2 3 4 5 6 7 8 9 TEST HOLE 20 sLoPE SITE PLAN DEPTH TO DATE READING JGROSS TIME ~ET TIHEI WATER NET DROP (MINUTES) (MINUTES) J (INCHES) (INCHES) ,~/(/$ TEST HOLE PRESOAKED PRIOR TO TESTING: -- PERCOLAT[ONRATE:~7~ (MIN/IN'CH) PERC. HOLE DIA. ,~ (INCHES) TEST RUN BETWEEN[ /'/'~ FT, and,, ~' FT. 'OMMENTS: TE~T HOLE PRE SOAKED PRIOR TO TEST, TEST PERFORMED BY ANDERSON ENGINEERiNG. I, M1CHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THiS DATE · Wockenfuss, Deborah M. From: Sent: To: Subject: Tobish, Thede G. Tuesday, August 16, 2016 2:17 PM Wockenfuss, Deborah M. On$ite permit #OSP161190 Deb, I have reviewed the parcel information for Lot 12Z, which has an open onsite application, # OSP161~.90. Given that the site was mostly filled in 2010 and after field checking the Pot today, I find that there are no wetlands on this lot and the permit should be clear of wetland concerns. Thede Thede Tobish, Senior Plat her Municipality of Anchorage-Plain'ting Dept. P.O. Box i96650 Anchozage, Al( 99519-6650 907.343.79]8 9073dS.7927FAX tobishtq@muni.orq AT00 DEPTH (~et) 1 2 3 4 5 6 7 8 9 11 20 MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT [~RAGAW STREET ANCHORAGE, AK 99519 6650 SOILS LOG - PERCOLATION TEST LEGAL DESCRIPTION: BLM LOT 127 PERFORMED FOR: ANDY NEWTON DATE: (3/5 I/16 PROJECT No.: PARCEL ID#: TECHNICIAN: SANDY GRAVEL WITH SILT TEST HOLE 5 ] WAS GROL~qD WATER ENCOUNTERED? __ IF YES @ WHAT DEPTH?___ DEPFH OF WATER AFTER MONITORiNG: DATE OF MONITORiNG:_ BOTTOH OF FILL 0G/0L SILTY SAND SN/NL BOH 15' d. PIILLETTE SLOPE No SITE PLAN GROSS TINE NET TIME DwE/~,~I~RT° INET DROP DATE READ[NO (MINUTES) (MINUTES) (INCHES) (INCHES) TEST HOLE PRESOAKED PRIOR TO TESTING: a/sul6 1 5:08 1.25" 2 5:38 30 11.63" 10.38" 3 5:39 1.13" 4 6:09 30 11.38" 10.25" 5 6:10 1.25" 6 6:40 30 11.50" 10.25" PERCOLATION RATE: 2.9 (MIN/INCH) PERC, HOLE DIA. 6 (INCHES) TEST RUN BETWEEN: 4 FT. and 5 FT. COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST, TEST PERFORMED BY ANDERSON ENGINEERING. I, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE: 9-1-16 1 $ 910 T7 ROW e 9P •, Municipality of Anchora.►'t JUN 12 2017 On-Site Water and Wastewater Program . ' (907)343-7904 �� �•. E T. Certificate of On-Site Systems Approval ~� Parcel I.D. 015-482-02 Expiration Date: q— 15 1 7 1. GENERAL INFORMATION Complete legal description T12N R3W Sec\ _ __ 15 Lot 127 Location (site address) 10251 Elmore Road Anchorage, AK 99516 Current Property owner(s) Andrew Newton & Raena Schraer Day phone 440-0541 Mailing address 10251 Elmore Road Anchorage, AK 99516 Real Estate Agent Day phone 2. TYPE OF DWELLING: 0 Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: Three 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well Q Individual Individual Water Storage ❑ Holding Tank ❑ Community Class Well ❑ Community ❑ Public Water System ❑ Public Sewer ❑ WaiverNariance request for: Distance: Received by: 4Matt hSLI'i Date: /007 COSA to be released to the engineer,unless otherwise requested by the engineer. COSA Fee $ 2-(o Waiver Fee $ Date of Payment (4)-- 1 - Date of Payment Receipt Number OT1 .°( CA Receipt Number COSA# CY,Ctl 2- )1 Waiver# 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm Anderson Engineering Phone 522-7773 Address P.O. Box 240773 Anchorage, AK 99524 Engineer's Printed Name Michael E. Anderson, P.E. Date 6/12/2017 OF 5.7 c . 491U `' ^,*�t� 6. DSD SIGNATURE •`•••°'°••`�°°°• ' 1" `' System #1 Approved for bedrooms '7;Mlct z,ti_ E. ANDERSON°:' System #2 Approved for bedrooms GE- 381 '�=rjJ • Disapproved 5v$8 PROFE5510y e� Conditional approval for bedrooms, with the following stipulations:��� � ON-SITE WATER AND PROGRAM WASTEW TER 3) By: tn.� 1 Original Certificate Date: f 1 7 The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On-Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: r COSA Checklist X Nitrate Advisory �� Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA blue sheet S '• c If more than 1 septic system is on the lot: COSA Checklist# of Structure served by this system Certificate of On-Site Systems Approval Checklist Legal Description: T12N R3V11 Section 15 Lot 127 Parcel ID: 015-482-02 A. WELL DATA Well type Private If A, B, or C provide PWSID # Well Log (Y/N) Y Date completed 10/13/16 Sanitary seal (YIN) Wires properly protected (YIN) Y Total depth 221 ft. Cased to 220 ft. Casing height(above ground) >18 in. FROM WELL LOG AT INSPECTION Date of test 10/13/16 1/19/2016 Static water level 1 59 ft. 38 ft. Well production 30 gp10.m. g P.m. WATER SAMPLE RESULTS: Coliform 0 colonies/100 mL Nitrate 6.61 mg/L Arsenic NDug/L Date of sample: 6/2/2017 Collected by: And. Engineering B. SEPTIC/HOLDING TANK DATA Tank Type/Material Septic/Steel Date installed 9/2/17 Tank size 1 '000 gal. Number of Compartments 2 Cleanouts(Y/N) Y Foundation cleanout(Y/N) Y Depression over tank(Y/N) N High water alarm (Y/N) N Date of pumping Pumper New Construction C. ABSORPTION FIELD DATA Date installed 9/2/17 Soil rating ? ? 1.2 GPD/SF 5' Wide (g.p.d,/ft2 or ft /bdrm) System type Length 38 ft. Width 5 ft. Gravel below pipe 4 ft. Total depth 7.4 ft. Eff. absorption area 380 ft' Monitoring tube Y Depression over field N Date of adequacy test New Const. Results (Pass/Fail) Pass For 3 bedrooms Fluid depth in absorption field before test in. Water added gal. New depth in. Elapsed Time: min. Final fluid depth in. Absorption rate >= g.p.d. N Any rejuvenation treatment(past 12 mo.) (YIN &type) If yes, give date D. LIFT STATION Date installed Size in gallons Manhole/Access(YIN) "Pump on"level at in. "Pump off"level at in. High water alarm level at in. Datum Cycles tested Meets alarm&circuit requirements? E. SEPARATION DISTANCES WELL ON LOT TO: Septic tank/lift station on lot >100' On adjacent lots >100' >100' Absorption field on lot X100 On adjacent lots >75' >100' Public sewer main Public sewer manhole/cleanout>25' >75' Sewer/septic service line Holding tank Animal containment areas >50' Manure/animal excrete storage areas >100' SEPTIC/HOLDING TANK ON LOT TO: Building foundation >5 Property line >5 Absorption field >5 Water main >10'10' Water service line >10'1 0' Surface water >100' Wells on adjacent lots >100' ABSORPTION FIELD ON LOT TO: Property line >10 Building foundation ��0 Water main 10 >10'Water Service line Surface water >1 Driveway, parking/vehicle storage Curtain drain None Noted Wells on adjacent lots X100' F. COMMENTS G. ENGINEER'S CERTIFICATION ��i•4-a�►�t�tiit1 ..'.; OF• ..q 1+i I certify that I have determined through field inspections and ,• A-�.9:f-s# review of Municipal records that the above systems are in „a • ,' .•.-7 'to conformance with MOA COSA guidelines in effect on this date. of • s49 TH-fy' .�S 0 Engineer's Printed Name Michael E. Anderson, P.E. . c- o, ... ..• ,�� Date 6/12/2017 �0��c*.MICHAEL E. ANDERSON'.�4 CE-4381 �, I4s':e�•.!v•-IZa7 . Ar 4 iq'idMrIty1','��. COSA brown sheet 10-10-12.doc • Municipality of Anchorage 1 t i_'� Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700 Elmore Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907) 343-7904 Nitrate Advisory Certificate of On-Site Systems Approval # OSC 171239 A Certificate of On-Site Systems Approval inspection and test of potable water was recently conducted on the well water supply on Block , Lot 127 of T12N R3W Sec.15 subdivision. This inspection revealed a nitrate concentration of 6.61 milligrams per liter (mg/L) was reported for the property's well water sample. The Environmental Protection Agency (EPA) has established a maximum contaminant level (MCL) of 10.0 mg/L for public drinking water systems. While private wells are not subject to this regulation, EPA standards are based on existing health information and can therefore be used to gauge the relative quality of water from private wells. Please see the attached "Nitrate Fact Sheet" for important information regarding nitrate. This advisory must be attached to all copies of the subject Certificate of On- Site Systems Approval. Nitrate Fact Sheet From Northern Testing Laboratories,Inc. Nitrate is a negatively charged compound of nitrogen and oxygen, which is very soluble in water. Nitrate is not readily filtered or otherwise removed in the soil and can pass rapidly into ground water wells. SOURCE: Nitrate is a major component of fertilizer and wastewater. Often the nitrate is in the form of ammonia or protein first, which through contact with oxygen and certain bacteria, converts to the oxidized form known as nitrate. Sources of nitrate from wastewater include urea, ammonia cleaners, food solids, and bacterial cells. It may also result from the breakdown of organic matter buried in the soil. TOXICITY: Nitrate is generally not toxic to adults or children over the age of two or three years, but is associated with a potentially fatal infant disease called methemoglobinemia. In the digestive system of young children, nitrate converts to nitrite, which can pass through the intestinal wall into the blood stream. There it combines with the hemoglobin and interferes with the ability of the blood to carry oxygen. For this reason, methemoglobinemia is referred to as "blue baby" disease. The EPA limits the concentration of nitrate in public drinking water supplies to 10 mg/L. The standard has been lowered from a previous level of 45 mg/L set by the US Public Health Service and the World Health Organization. TREATMENT: due to its solubility in water and negative ionic charge, filtration and other common home water treatment systems such as softening or iron filtration does not readily remove nitrate. The best method for limiting nitrate in well water is source control. This can include avoiding overdosing of fertilizer near the well and maintaining good separation distances between septic tank leach fields and the well. A special anion exchange filter that contains a media with a strong affinity for negatively charged ions in water, or by a reverse osmosis treatment system or distillation can remove nitrate. TESTING: Nitrate analysis is usually done by one of the several "wet chemical" methods using a spectrophotometer to read the final color endpoint. Specific ion electrodes also can be used to detect the activity of nitrate in water. This laboratory uses several different wet chemical methods approved under the public water supply laboratory certification program. They also have test kits available, which the laboratory uses to perform an inexpensive "screening test", and with which the homeowner can monitor the change in nitrate levels from their well. They recommend comparing the test kit results against a certified analysis from the lab occasionally to verify the accuracy of the kit. We recommend using a specially prepared bottle that has been rinsed in hydrochloric acid for collecting samples. I % .. \ BLM Lot 126 50.0' N 90'00'00"E 279.90' BLM Lot 127 . 46,200 s.f. z. / BLM Lot 125 r z / \ 4 o 109.4' — o \ 0 a -. 31.0 o 1 Q GRAVEL . DRIVEWAY o m XJ if '„,-;---- -3; 119.4" zo.D' WELL a) rn Q , `�--1 STORY -,'• v' 51.0' q RESIDENCE ,o a W�� w SEPTIC ai \ 0 x/449 PIPES \ ' " / Ve o N 90'00'000"W 279.86' 0 WIRE FENCE BLM Lot 128 BLM Lot 130 I � PLOT PLAN AS BUILT X SCALE 1" = 60' GRID SW 2536 Project No. 17-149/A1 11500 Daryl Avenue, Anchorage, Alaska 99515-3049 Lang & Associates , inc . (907) 522-6476 Phone Q,��opOD (907) 522-4625 Fax Qo OF AL�Q4 Professional Land Surveyors kenOlangsurvey.com v .. .. n jonathonOlongsurvey.com . I hereby certify that I hove surveyed the following described property: 0Ov BLM Lot 127, SECTION 15. T12N, R3W, SEWARD MERIDIAN, ALASKA 0 * •' 4�� . *SOA Anchorage Recording District, Alaska, and that the Improvements situated thereon are within the property lines and do not encroach onto the property adjacent thereto, that no Improvements on the property lying adjacent thereto encroach on the surveyed �' KENNETH premises and that there are no roadways, transmission lines or other visible 4a�, e5 easements on said property except as Indicated hereon. •tt t t l L'1 p '•..�5-5202,. ' SJpO Dated this the 1-,'-• Dayof �y= 1 at Anchorage, Alaska �,o •••••'' o co At‘ FESssior�A1.14e It Is the responsibility of the owner to determine the existence of any easements, DODooQ�o covenants, or restrictions which do not appear on the recorded subdivision plat. AECC963