HomeMy WebLinkAboutHART LT 93B N u c_ pallityo A chora e DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION 825 "L" STREET ANCHORAGE, ALASKA 99501 (907) 264-4111 GEORGE M. SULLIVAN, MAYOR February 14, 1980 Howard J. Grey._ MOENING-GREY AND ASSOCIATES, INC. 715 L Street - Suite 8 Anchorage, Alaska 99501 Subject: Lot 93B Hart Subdivision Mound Design Dear Mr. Grey: Your as-built is acceptable and adequate regarding permit requirements of this department. Sincerely, Les No Buchholz, R.S. Senior Environmental Specialist LNB/ljw cc: Mr. John Mc Laughlin Star Route A Box 448R 99507 ENVIRONMENTAL ENGINEERING DIVISION ,_ 825 L Street- Anchorage, Alaska 99501 Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT NAME PHONE I ~NEW John McLaughl in 344-9285I [] UPGRADE MAI LING ADDRESS Box 488 R SRA Anchorage, Alaska 99507 LEGAL DESCRIPTION Lot 93 B, Hart Subdivision LOCATION NO. OF BEDROOMS 3 ] Well Absorption area ! Dwelling PERMIT NO. _~ DISTANCETO: I I 8 F.eet 14 Feet ~- 2 Manufacturer Materiai No, of compartments ~ ~ Greer Steel 2 Liq. ca~c~t~ in gallons IF HOMEMADE: Inside length Width Liquid depth ~ v DISTANCE TO: Well Dwelling PERMIT NO. O Z <~ Manufacturer Material Liquid capacity in gallons ~ We]] Foundation Nearest lot line PERMIT NO.  DISTANCE TO: 20 Feet 35 Feet 7qrl43.~ No, of lines Length of each line Total-length of lines Trench width Distance between lines 4 40 l~O F ~F~ ~'. ~ inches 7_~ Top of tile to finish grade Material beneath tile Total effective absorption area 2 Fee' - Minimum SP. 78 Minimum inehas 480 .qn. F~t , Len§t~ Width Depth PERMIT NO. ~ I- Type of crib Crib diameter Crib depth Total effective absorption area ~u Well Building foundation Nearest lot line m DISTANCE TO: .~ Class Depth Driller Distance to lot line PERMIT NO, ~ DISTANCE TO: ! Budding foundation Sewer line Septic tank Absorption area(s) OTHER PiPE MATERIALS 4" PVC. (ASTM-3f134;ASTM-?l?9) ;EL AT"A£~ED SH:FT SOl L T EST RATING SM/ML INSTALLER John McLaughlin R EMAR KS Installed to design specifications 71/' k ...... APPROVED ' ' DATE LEGAL MOENING-GREY & ASSOC., INC. 1/30/80 By: Alvin R. Zeman o Q ~- ALASKA 99501 December 31, 1979 John Mc Laughlin Star Route A Box 488R Anchorage, Alaska 99507 Permit ~ 790435 Subject: Lot 93B [{art Subdivision A permit issued by this department for well and/or sewer system has expired. Permits are issued on a calendar year basis, as stated on the permit, by authority of Municipal ordinance. If you have drilled the well, a well log should be sent to this department to document the installation date. If an engineer has inspected the installation of the on-site sewer system, please have them send us the as-builts for our files. If there are any further questions, please contact this office at 264-4720. Sincerely, Les N. Buchholz, R.S. Senior Environmental Speci~?ist LNB/i j w enc: Copy of Permit e' DEPSRTMENT OF HEALTH f~ND ENVIRONMENTRL PROTECTION .~ 825 'L' STREET, 8NCHORRGE, 8K. 9950i 264-47R0 COPY MUST 8E 08TRINED FROM THE FILES - DBTR NOT BgBILRDLE IN THE COMPUTER MOENING-GREY & ASSOCIATES, INC. GEOLOGISTS AND ENGINEERS 713 L STREET, SUITE 8 ANCHORAGE, ALASKA 9930! TELEPHONE (907) 274-2S14 July 31, 1979 Municipality of Anchorage Department of'Health and Environmental Protection 825 L Street Anchorage, Alaska 99501 Attn: Les Bucholz Subject: On-site mounds design of a sewer disposal system for Lot 93B of Hart Subdivision, Owner John McLaughlin. Gentlemen: Enclosed for your review and approval is our design for a mound type of sewer disposal system for the subject property. This type of design was required due to a high groundwater condition identified in a soil~, report prepared by a Mr. Michael B. Bergman, (see attached copy). Our firm has not to date conducted a confirming soils inves- tigation. However, we did briefly inspect the site, which had a shallow backhoe test pit, and confirmed the existence of groundwater near the surface. Site slopes and elevations for the design were furnished by the owner. Performance of the designed system will require close super- vision of construction, and adherence to the design require- ments. Please let us know if you have any questions. Respectfully submitted, MOENING-GREY~~ES, INC. Howard J. G~,'~/ ~ugust 29, 197~ Ms. Konni Snyder Totem Realty Inc. 621 W. Dimond Blvd. Anchorage, Ak 99502 Subject: Soils investigation for sanitary sewer system; Lot 93B, Hart Subdivision, Anchorage, Alaska. Dear Ms. Snyder At your request of August 23, 1978, I conducted a soils investigation at the proposed location of a sanitary sewer system on the subject lot. This investigation, which was accomplished on August 27, 1978, consisted of the inspection of soils removed during drilling of two test holes. The test holes were drilled by a trailer mounted Mobile B-34 drill rig using 4 inch diameter solid flight augers. Test Hole #1 reached a total depth of 11.0 feet and Test Hole #2 reached a total depth of 7.5 feet. A water table was encountered in both test holes. The water table waS found at 6.5 feet in Test Hole #1 and at 7.0 feet in Test Hole #2. The greater depth of the water table in Test Hole #2 is attributed to a slight raise in surficial elevation between Test Hole #1 and Test Hole #2. Both water tables were measured after boring. The soils encountered are graphically shown on the accompanying test hole boring logs. The soils consisted of a layer of Organics and Organic Silt approximately 3'feet thick overlying a Sandy Silt form 2 to 2.5 feet thick, underlain by a Silty Gravel with some Sand to total depth in both holes. The topography of the area where the soils test was conducted is generally flat with a very slight upslope to the East of approximately 1-2%. Vegetation on the lot consisted of dense birch and spruce 30-40 feet tall, with a ground cover of low bushes and tall grasses (2-3 feet tall) and some mosses. A percolation test was conducted on Test Hole #2. The results are tabulated on an accompanying sheet. An accompanying sketch shows the subject lot with the test hole locations in relation to the property lines. I appreciate the opportunity to be of service to you. Please contact me if you have any questions regarding this soils investigation. Consultin~/Geologist Box 191,~Star Route A Anchorage, Alaska 99502 (907) 344-9150 Attachments: Drawing of test hole boring logs with location sketch, and tabulation of percolation test results. xc:Department of Health and Environmental Protection, Mr. John J. McLaughlin and William F. Hart. ~ of/ .Jinage ditch & ~ ~ ~' easement S89°44'06"E ' / S00°15'54"W 165.04' L ~ ~__ I 1__0 '__utili__ty__ea__se__Jen__t__ / ~ \ ~,~ ~.:~5.~ I I1 ~ \ x ~/~.. /=74°0~'40"I Lot 93, Hart Subdivision, I ~ncho=age, Alaska I William F. Hart Property , 64' '--'. T.H.d. 2 ~ N00°07'00"W 165.08' --Patent reserve for R.O.W. 3' -- Loch Lomond Road.-- NOT TO SCALE Distances are approximate and have not been measured by surveying methods as to locations of test holes. Michael B. Bergmann Consulting Geologist Box 191, Star Route A Anchorage, Alaska 99502 (907)344-9150 T.H. No.1 8-26-78 0.0' Organics & Organic Silt, trc ---%~nd & gravel, occ cobble, ~ist, loose, dk brn. 0.5' Organic Silt: w/rfc sand & gravel, occ cobble, moist, loose, dk brn. -- -~ (o~,) ~.-- -- --- 3..0' ;andy Silt; w/fro gravel, occ cobble, moist, loose, gray. -- "~ (SM-ML) 6.5'AB~-- 5.0' ;ilty Grove]: w/some sand, occ cobb]es, wet l:c) vv wet, med dense, gray. (GM) ll.0'TD T.H 8-2E 0.0~ & Organic Silt, -- -'%~oist, loose, dk brn. ~--- -- 0.5' )rganic Silt: moist, loose, dk bm. (OL) -- 3.0' ;andy Silt: moist, loose, gray. (SM-ML) 5,5t Grave].: w/some sand, occ cobble, vy moist to vy wet, 7.0'AB med dense, gray. (GM) 7.5'TD Test hole boring logs represent soils encountered on Lot 93, Hart Subdivision, Anchorage, Alaska " August 29, 1978 Subject: Percolation test on Test Hole #2, Lot 93B, Hart Subdivision, Anchorage, Alaska. The percolation test was performed on August 27, 1978, by filling a 4 inch diameter, 7.5 foot deep test hole with water and measuring the water level drop periodically for one hour. TABULATION OF PERCOLATION TEST RESULTS TIME LEVEL (inches) DROP (inches) ET (min) 1756 13.5" start start start 1806 36.5" 23.0" 10 0.4 1816 37.5" 1.0" 10 10 1826 38.5" 1.0" 10 10 1836 38.75" 0.25" 10 40 1846 39.25" 0.5" 10 20 1856 39.75" 0.5" 10 20 RATE(min per inch) Average percolation rate for entire hour = 2.3 minutes per inch Average percolation rate for last one half hour = 24.0 minutes per inch Consulting Geologist Box 191, Star Route A Anchorage, Alaska 99502 (907) 344-9150 February 8, 1980 MOENING-GREY & ASSOCIATES, INC. GEOLOGISTS AND ENGINEERS 715 L STREET, SUITE 8 ANCHORAGE, ALASKA 99501 TELEPHONE (907) 274-2314 MUNICIPALITY OF ANCHORAGE DEPT, OF "~ ~ ,zALTH & ENVIRONMENTAL P;',OTECTION FEB 3 1980 RECEIVED Municipality of Anchorage Department of Health & Environmental Protection 825 L Street Anchorage, Alaska 99501 Attention: Les Bucholz Subject: On-Site Mounds Design of a Sewer Disposal System for Lot 93 B, Hart Subdivision, Owner John McLaughlin Gentlemen: Enclosed for your review is the as-built report of the mound type sewer disposal system for the subject property. Please let us know if you have any questions. Respectfully submitted, MOENING-GREY & ASSOCIATES, INC. Patrick Sti dmon PS/lg aueq u~mol 3oq Well ! Pump ,Seryice July 8, 1980 R & S DRILLING COMPANY 6901 Tanaina Drvie Anchorage, Ak 99502 Drilled for: Sanibel Builders Box 10-563 Anchorage, Ak 99511 (907)349-3140 Legal Description: Lot 93B Hart Subdivision Well Cased to: Well Drilled to: Static Water Level: Draw down Water Level: Peat Decreasing Peat, small gravel and surface Clay decreasing to small gravel Clay with Some Rock Decreasing Clay to Sand then Water (5+ gpm) ACCEPTANCE 39 feet 43 feet 8 feet from top 25 feet from top 0 to 5 feet 6 to 10 feet 11 to 15 feet 16 to 38 feet 39 to 43 feet SANIBEL BUILDERS DRILI,ER 0 o~ ~-~ ~ · H 0 t~tN .ri ~ 0 H © M bO .H 0 October 20~ 1978 Michael Bergs. ann Star Route A Box 191 ~chorage, Alaska 99507 Subject: Lot 93B Hart Subdivision Dear ~{r. Bergmann: This department has reviewed the soils test submitted on October 19, 1978 and find the following: (1) Water table at seven(7) feet. (2) Organic sl..t-molst to three(3) feet. Municipal Ordinance mandates that sewage be disposed of four(4) feet above the water table. Stratification of soils reported in the. soils test(test hole ~2) show the layer available for sewage disposal consist of organics which are unsuitable° Therefore~ based on the soils test submitted to this department, a permit can not be issued for a residence on this lot. An alternative available at considerable financial expense is the removal of the organic silt layer and replacing it with well-graded shadS. However, systems of this nature are susceptible to freezing. If there are any further ~estions~ please contact this office at 264-4720. Sincerely, Lynn Bringle Senior Enviro~n~ental Officer LB/ljw October 18, 1978 · Mr. William S. Hart c/o Real Estate Corner of Alaska 555 W. Northern Lights Blvd. Anchorage, Alaska 99503 Subject: Percolation test on: Lot 93B, Hart Subdivision, Anchorage, Alaska. Dear Mr. Hart: At the suggestion of the Department of Health and Environmental Protection, I perfor- med a second percolation test on your property. This test was performed utilizing only the top 2.5 feet of soil, resulting in a more accurate assessment of the ability of this interval to accept the effluent from a sanitary sewer System. The test was performed by hand augering a 6 inch diameter, 2.5 feet deep test hole into the highly organic soil (bottoming out at the top of the Sandy Silt), filling it with water and measuring the water level drop periodically for one hour. This percolation test hole was located 3 feet due east of Test Hole No. 2. The test was performed on- October 3, 1978. TABULATION OF PERCOLATION TEST RESULTS TIME LEVEL(inches) DROP(inches) ET(min) 1434 7.25" start start start 1444 16.0" 8.75" 10 1.1 1454 19.0" 3.0" 10 3.3 1504 21.0" 2.0" 10 5.0 1514 22.5" 1.5" 10 6.7 1524 23.25" 0.75" 10 13.3 RATE(min per inch) 1534 24.0" 0.75" 10 13.3 Average percolation rate for entire hour = 3.6 minutes per inch Average.percolation rate for last one ~half hour = 10.0 minutes per inch I appreciate the opportunity to be of service to you. Please contact me if you have any questions regarding this percolation test. Very tr~] yours, Michael B.~ergmann Consu!~ Geologist Box 191, Star Route A Anchorage, Alaska 99502 (907)344-9150 xc: Department of Health and Environmental Protection '--~? - DATE RECEIVED -"~ ~ INSPECTION APPOINTMENTS ~~__.~..~ ~ TIME TIME TIME DATE DATE DATE INSPECTOR INSPECTOR I NSPEOTOR MVNICIPALITY O AGE DEPT. OF HEALTH & MUNICIPALITY OF ANCHORAGE ENVIRONMENTAL PROTECTION OCT 1980 ENVIRONMENTAL SANITATION DIVISION Telephone 264-4720 R E C E J V ~ D REQUEST FOR APPROVAL OF INDIVIDUAL WATER AND SEWER FACILITIES DIRECTIONS: Complete aH parts on page 1. Incomplete requests will not be processed. Please allow ten (10) days for processing. MAI LING ADDRESS ~ ' ~ PROPERTY RESIDENT (If different from above) ' PHONE PHONE MAI LING ADDRESS 3. LENDING INSTITUTI~ . PHONE MAILING ADDRESS 4. REALTOR/AGENT ~ PHONE I MAILING ADDRESS 5. LEGAL DESCRIPTION STREET LOCATION~/p 6. TYPE OF RESIDENCE ~NGLE FAMILY [] MULTIPLE FAMILY NUMBER OF~BEDROOMS [] One [] Four ~ Two [] Five [] Three [] Six [] Other 7. WATER SUP~Y ~ INDIVIDUAL* [] COMMUNITY [] PUBLIC UTILITY * ATTACH WELL LOG. A well log is required for all wells drilled since June 1975. For wells drilled prior to that date, give well depth (attach log if available.) 8. SEWAGE DISPOSAL SYSTEM E~"~I N DI VI DUAL/ON-SI TE** [] PUBLIC UTILITY YEAR ON-SITE SYSTEM WAS INSTALLED. NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED. 72-010 (Rev. 6179) ~ //~.~ THIS SIDE FOR OFFICIAL USE ONLY 1, TYPE OF RESIDENCE NUMBER OF BEDROOMS [] SINGLE FAMILY [] ONE [] THREE [] FIVE [~ OTHER [] MULTIPLE FAMILY [] TWO [] FOUR [] SIX PERMIT NUMBER 2, WATER SUPPLY [] INDIVIDUAL DEPTH OF WELL [] COMMUNITY DATE DRILLED [] PUBLIC UTILITY Connection Verified LOG RECEIVED 3. SEWAGE DISPOSAL SYSTEM PERMIT NUMBER [] INDIVI DUAL/ON -SITE DATE INSTALLED []PUBLIC UTILITY I ~.=% ~- ~ (:3 Connection Verified INSTALLER [~]Septic Tank or []Holding Tank Size: ~;~)(~CZ:) If Tank is homemade SOILS RATING give dimensions: TYPE OF TANK MANUFACTURER TOTAL ABSORPTION AREA MATERIAL 4. DISTANCES WELL TO: Septic/Holding Tank Absorption Area Sewer Line Nearest Lot Line Absorption Area to nearest Lot Line 5, COMMENTS / E~/~PPROVED FOR -)' BEDROOMS [] CONDITIONAL APPROVAL (letter must accompany certificate) DATE BY ,..~) 825 "L" STREET ANCHORAGE, ALASKA 99501 (907) 264-4111 GEORGE M, SULLIVAN, MAYOR DEPARTMENTOFHEALTHANDENVIRONMENTALPROTECTION Love/Coble Property October 8, 1980 Carol Ann Love Post Office Box 10-563 Anchorage, Alaska 99511 Subject: Lot 93B Hart Subdivision Approval for your individual sewer and water facilities cannot be granted until the following items have been completed: (1) A well log submitted to this department for our review. (2) The water analysis report be delivered to this department from Chem Lab, 5633 B Street, for our review. If there are any further questions, please call this department at 264-4720. Sincerely, Robert C. Pratt, R.S. Associate Specialist RCP/ljw cc: Alaska Pacific Bank 101 Benson Boulevard 99503 GREATER ANCHORAGE AREA BOROUGH Department of Environmental Quality 3330 "C" Street, Anchorage, Alaska 99503 274-4561 Date Received Time of Inspection Date of Inspection 1. ApprOval 'requested by: Mailing Address: ~ ~"~ 2. Property Owner: REQUEST FOR APPROVAL OF INDIVIDUAL SEWER & WATER FACILITIES FOR Phone: Phone: Mailing Address: 3. Legal Description: L'rq~ 4. Location' 3//~ ~ ~ 5. Type of facility to be inspected ~, ~~ No. of bedrooms ~ ~. 6. Wel 1 Data: A Type ~~ C. Construction D. Bacterial Analysis Sewage Di sposa 1 System: ~/S~/;>v: A. Installed~/~_/~ -- B. Installer ~/x~-~;~ ///~/~'~A?'~ ~:'~2/ Manufacturer C. Septic Tank: 1. Size · D. Seepage Pit: 1. Absorption Area ///~//~. 2. Material E. Disposal Field: Total length of lines Distances: ~_/~2~- C~'~qT'Y~-'-h A. Well to: Septic tank , Absorption area Nearest lot line /~ /~/'~ , Other contamination , Sewer Lines B. Foundation to septic tank , Absorption area C. Absorption area to nearest lot line F~l-rlga {1/7al Paqe 1 of two paqes Page 2 of two pages - Re¼.~st for Approval of Individual . :er & Water Facilities Legal ~escription :T~>y- .,~~.~. .... ._., Approved Oi sapproved Approval Valid for one year from date signed Greater Anchorage Area Borough, Department of Environmental Quality DIAGRAM OF SYSTEM I certify that the information contained in this request for approval to be a true and accurate representation of the subject sewer and water facilities and these facilities are operating satisfactorily. SIGNED Date ~une 13~ 1~74 S.R.Ao ~ox 481 Anchorage, Alaska 99507 SUBJECT: On-site sewer and water facilities serving 2-bedroom, sangle family dwelling: Lot 93, ~(~ 1/4. Sec. 33, T12H, Dear Mr. Hart: At your request this Department inspected the on-site sewer and water facilities at the above location on June 6,,1974. The facilities cannot be approved by this Oepart~ent as it is unknown what the se~er system consists of. There is one standpipe in the yard lecated 40' from the well. If this is a cesspool the followtn~ ~obld be needed: 1) A 1000 gallon septic tank installed a minimum of 50' from the ~ell. 2) A seepage pit or drainfteld installed a minimum of 100' from the well. 3) A permit from this Bepartment to install the system and inspection prior to backfill. (Uo charge for this service) The water sample obtained from the well is satisfactory; however, we would like to advise you again that if there is a cesspool located 40 feet the well this is in violation of State and Borough laws which require septic tanks to preceed the absorption area and the absorption area be located a minimum of 100 feet from the well. Also, if the situation exists the well could become contaminated from the sewer syste~, posing a serious health hazard to anyone using or drinking the water. )t is for this reason we strongly urge you to determine what the system consists If we can he of further assistance please do not hesitate to call on us. Sincerely, C. Sue~cKechnte, R. S. £nveromental Control Officer III CM/ko