HomeMy WebLinkAboutHAUGEN LT 1 ~~ MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION ENVIRONMEN'I'AL ENGINEERING DIVISION 825 L Street- Anchorage, Alaska 99501 Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT NAM~__~I IPHONE I E]~EW MAI LING ADDRESS ', I ,,~,~' .~ ,,V I Absorption area Dwelling PERMIT ~0. ~X DISTANCE TO: LUI fl~(,[r)ll' I ~<~Z ManufacturerC~¢~:E~ .~ Mate~¢ No. of compartments ~ Liq. c,~i.~llons iF HOME.DE: Inside length ~ Width ,- Liquid depth ~ ~ DISTANCE TO: Well ~ Dwelling PERMIT NO. O ~ ~ Manufacturer Material Liquid capacity in gallons ~ W ~¢ Fou~datio~ Nearest lot li~e/)~/ PERMIT NOJ No. oflines / Length of each lin?~ ,' Total length of li~, Trench widt~nches Distance betw~nes ~ ~ ~ Top of tile to finish grade : Material beneath tile ~ f~.-S .F/z/ ~ // FC2~ ~nches Total effective absorptio~ar~/ Length Width ' Depth PERMIT NO. < ~ Type of crib Crib diameter Crib depth Total effective absorption area ~ Well Building foundation Nearest lot line ~ DISTANCE TO: ~ Class Depth Driller Distance to lot line PERMIT NO. ~ Building foundation Sewer line Septic tank Absorption area(s) ~ DISTANCE TO: OTHER PIPE MATERIALS INSTALLbR -- ~ ~- REMARKS . . APPROVED DATE LEGAL ~q4UNICIPALITY OF ANCHORAGE-~-x Department. .: Health and Environmenta_ ?rotection 825 L Street, Anchorage, AK. 99501 264-4720 * * * HANDWRITTEN PERMIT * * * Permit ~/~'c~x~'"~,~"~ ON-SITE--~ SEWER PERMIT Applic~t: ~< ~ Mailing Address: ve cr vt o : / Type of Soil ~sorption System./Is: Trench: Drainfield: ~Seep~ge Bed. Holding Tank ~aximum N~ber of Bedrooms: ~ Soil Rating(sq.ft/br) DEPTH The Required Size of the Soil Absorption System Is: ! LENGTH ~ GRAVEL DEPTH ~ WIDTH The length dimension is the length(in feet) of the trench or drainfield. The depth of a trench or pit is the distance between the surface of the ground and the bottom of the excavation(in feet). There is no set width for trenches. The gravel depth is the minimum depth of gravel between the outfall pipe and the bottom of the excavation(in feet). * * REQUIRED SEPTIC(HOLDING) TANK SIZE = /~"O GALLONS * * Permit applicant has the responsibility to inform this department during the installation inspections of any wells adjacent to this property and the number of residences that the well will serve. * * * TWO(2) INSPECTIONS ARE REQUIRED * * * Backfilling of any system without final inspection.and approval by this department will be subject to prosecution. Minimum distance between a well and any on-site sewage disposal system is 100 feet for a private well or 150 to 200 feet from a public well depending upon the type of public well. Minimum distance from a private well to a private sewer line is 25 feet and to a community sewer line is 75 feet. Well logs are required and must be returned to this department within 30 days Of the well completion. Other requirements may apply. Specifications and construction diagrams are available to insure proper installation. * * * PERMIT EXPIRES DECEMBER 31, 1 9 8 3 * * * I certify that: (1) I am familiar with the requirements for on-site sewers and wells as set forth by the Municipality of Anchorage. . (2) I will install the system in accordance with codes. (3) I understand that the on-site sewer system may reJ~uire enlar~ement if the~esi~ence is rer~deled to include more that/~//bedrooms//j SigneR: ~~~/~/~~% ~-'"/~.,~ IS sued by: ~~--~~ ~ppl~ant-''- {%'"/ - Date: ~,~· SWP/024 (1/81) MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION 825 L, Street, Anchorage, Alaska 99501 264-4720 SOILS LOG - PERCOLATION TEST /~ SOILS LOG [] PERCOLATION TEST 4 SLOPE DATE PERFORMED: SITE PLAN 0 ~"//'/ 10 11 12 13 14- 15- 16- 17- 18- 19- 20- WAS GROUND WATER ENCOUNTERED? tF YES, AT WHAT DEPTH? Gross Net Depth to Net Reading Date Time Time Water Drop Leroy C. Reid, Jr. No. 2251.E PERCOLATION RATE (minutes/inch) TEST RUN BETWEEN FT AND ~ FT COMMENTS PERFORMED BY: ~' R~-, (3/ CERTIFIED BY: DATE: ~'/7~' 72-008 (6/79) ALASKA ENVIRONMENTAL CONTROL SERVICF-~INC. !200 West 33rd Avenue Suite B ANCHORAGE, ALASKA 99503 Phone 276-136! SHEET NO. OF CALCULATED BY DATE CHECKED BY DATE SCALE :, ...... ! ........ i ........ ....... ! i. ! ~. :, i ..~:~-. !/4'o ....: . i : : i ......... i .: i ^LASKA e?"IRO meI TAL CO[1TROL seR' "se$, I c. I~,~i~¢¢rin§ 8 (~nuirenmcnlal St~l~Jcs September 12, 1983 Alaska Department of Environmental Conservation 437 E. Street Anchorage, Alaska 99501 Attn: Mike Mathews Dear Mike: On August 19, 1983 AECS, Inc. verified the abandonment of the well located on Lot 1, Block 0, Haugen Subdivision. The casing was filled to the top with concrete. If you have any questions please feel free to contact our office. Thank you. Sincerely~ Pre. dent cc: Department of Health & Envirnomental Proections Files 1200 ~¢sl 33rJ Au~,u¢, $uii¢ I~ · A,cbroq~,/~losb 99503 · {907) 276-1361 ALASKA i, iBo[ m [1TAL CO[1TBOL II1C. J~n§ineerin§ 8 I~nuironrnenlal $1udics August 18, 1983 Syren & Sons 2330 East Tudor Road Anchorage, Alaska 99507 Attn: Roy Dear Roy: At your request on August 18, 1983 I visited Lot 1 & 2 Haugen Subdivision which is owned by Dick Kim. On lot 1 was a old crib system that you had collapsed the day before on order from the Health Department. Fifty-three feet from this old crib is a Class C well. The well lies at approximately 51 feet from the septic tank or crib on the Union Station located on the adjacent lot to the east of lot 1. We determined that since this was a Class C well and 150 foot radius would be necessary to protect the well, and that it would be impossible to get an on-site sewer system on this lot with the well to continue to be used. I noted that in Tudor Road there were water valve boxes indicating to me that public water is available to this lot. Public sewer is available approximately one. lot to the north of Mr. Kims lot. I feel that most expedient thing for Mr. Kim to do would be to abandon the Class C well and pour it full of concrete up to the static water level then hook up to the public water system. The test pit that you dug for me later in the day indicated a very good sandy gravel from 3 to 10.5 feet that I rated at 100 square foot per bedroom. Water was at 10.5 feet. This would mean that the sewer system could be put in from 3 to 6.5 foot depth without creating any problem. As the the house is a double wide modular unit there shouldn't be any trouble in getting the septic tank installed in the 3 foot level. Enclosed are the results of the soils log and schematic sketch of the system. There is approximately 64.5 feet from fence to fence in the yard that could be used for a single run. Mr. Kim asked me the possibility in hooking his station septic tank onto the same system. Looking the lot over I believe that it would be impossible to sell the two lots as individual lots because part of the gasoline tanks for the store on Lot 2 appears to be over on Lot 1. $o I believe that if the two lots could be considerated as an integral unit. I have consulted with the Health Department on this and there answer is that it would be possible to do this. We should put a 1000 gallon septic, tank at the rear of the gas station and it should only serve the stations two bathrooms and not be connected to any floor drains. There would be a 1000 gallon tank for the three bedroom home. The drainfield would be designed for 6 bedrooms. The depth of gravel would be 3 ft under the pipe and 5 feet wide. The total depth is 6.5 feet. The length would be 70 feet. An alternative for Mr. Kim would be to put a 1000 gallon septic 1200 ~Uesl 33rd Aocnu¢, 5uii¢ ~ · Anchoroqe, Abko 99503 * (907) 276-1361 tank and drain field for the station with 35 feet of trench to the same specifications. If drainfield for both systems are placed on the same lot then a maintenance easement needs to be recorded in insure access in case one lot is sold. If you have any questions please feel free to call me. Sincerely, cc: Health Department Leroy C. Reid Jr., PhD PE President PO iH 6-65O ANCHORAGE, ALASKA 99502 0650 (907) 264-4 TONY /~N,OWI /.,,fA Y Of~ DEPARTME~,~T OF HEALTH ,AND ENVU:~ONMENTAL P~-,~OTECTION August 16, 1983 Dick Klm 2715 East Tudor Anchorage, Alaska 99507 Subject: Lot 1 Haugen Subdivision Cesspool Per Judge Souter's instructions on 8/16/83, I inspected the mobile home at lot i Haugen Subdivision to verify that the sewer line was disconnected from the cesspool. At 10:30 A.M. the line was intact. By 11:00 A.M. the line was disconnected and capped satisfactorily. To recap our conversation: In order to verify the location of all neighboring wetls~ provide this depart- ment with an engineer's survey of your property and all properties within a 200 foot radius by August 22, 1983. Included in this report will be the number of dwellings, businesses or connections each well serves. It will also contain any septic systems or cesspools'within the 200 foot radius. I have enclosed a list of engineers for your conveniences The permit 830560 to install a holding tank is hereby revoked pending the submittal of the engineer's report~ The revocation of permit #830560 is due to the fact that the class "C" well serving the gas station and the mobile home does not comply with the necessary' protective radius from all sources of contamination. You must not install the holding tank until you receive per- ~i~-~ion from this department. I have enclosed a copy of the ~chorage Wastewater Disposal Regulations for your conven£ence. All household wastewater is considered sewage per ordinance 15.65.020. If you run water in the mobile home it must be disposed of in an approved manner. The cesspool is to be caved in and fllle~w%th dirt to prevent cave-ins or future use. If you have any farther questions please call me at 264-472Q. Lynn' Lind~ist Principal Code Enforcement Officer cc: So Flemming ~ Municipal Attorney ~-~UNICIPALITY OF ANCHORAGE,--"-, Department.' Health and Environmenta £rotectlo n 825 L Street, Anchorage, AK. 99501 ~ ~ ~ ',? 264-4720 * * * * * * HANDWRITTEN PERMIT Permit ~ Applicant: ON-SITE SEWER PERMIT Location: Legal Description: Type of Soil Absorption System Is: Trench: Phone Number: 7 ~/TyF/..k Lot ~ Drainfield: ~ Seepage Bed: d~} ~olding Tank: Maximum Number of Bedrooms: The Required Size of the DEPTH Altt- LEN T. Soil ft/br) rption System Is: ' '.PTH ~/~ WIDTH The length dimension is the lenc depth of a trench or pit is the bottom of the excavation(i~ The gravel depth is the the bottom of the * * REQUIRED Permit applicant has the installation ins of residences that t ~t) of the trench or drainfield. The e between the surface of the ground and There is no set width for trenches. ~h of gravel between the outfall pipe and ~et). S) ~ = ~'~:~) GALLONS * * ibility to inform this department during the wells adjacent to this property and the number serve. * * * ,(2) INSPECTIONS ARE REQUIRED * * * Backfilling of any sys without final inspection and approval by this department: will be subject to p~ ecution. Minimum distance b a well and any on-site sewage disposal system is 100 feet for a private 150 to 200 feet from a public well depending upon the type of public well Minimum distance from a private well to a private sewer line is 25 feet and a community sewer line is 75 feet. Well logs are required and must be r, rned to this department within 30 days of the well completion. , Other may apply. Specifications and construction diagrams are available insure proper installation. * * * PERMIT EXPIRES DECEMBER 31, 1 9 8 3 * * * I certify that: (1) I am familiar with the requirements for on-site sewers and wells as set forth by the Municipality of Anchorage. (2) I will install the system in accordance with codes. (3) I understand that the on-site sewer system may require enlargement if the residence is remodeled to include more that ~bedrooms. SWP/024 (1/81) DIRECTIONS TO PROPERTY TO BE INSPECTED Sewer and Water Program Note: be sure to put colour of house or other landmarks that will make it easy for the inspector to find. Accurate directions will save time and not cause delays in scheduling · ~