Loading...
HomeMy WebLinkAboutMOUNTAIN PARK ESTATES BLK 12 LT 9 Municipality of Anchorage Page 1 o! 3 DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744 On-Site Wastewater Disposal System and/or Well Inspection Report Permit Number: SW980272 PIDNumber: 017-391-48 Name: Spinell Homes Wastewater System: ~ New [] Upgrade Address: ABSORPTION FIELD 9210 Vanguard Drive Anch., AK No. of Bedrooms: Phone: 344--5678 ~[-~Deep Trench [] Shallow Trench [] Bed [] Mound [] Other Tolal Depth from original grade: LEGAL DESCRIPTION Soil Rating: 45 · GPD/Sq. Ft. 1 2 i _ Block: Subdivisio,n: 0eplh Io pipe bottom from original grade: Gravel depth beneath pipe Lot: 9 12 Mtn. ParJ~ Est. 6 Ft. 6 Ft. Township: I Range: ISectiOn: Fill added above original grade: Gravel length: 84 2 Ft. Ft. Number of lines: Distaece between lines: WELL: [~ New [] Upgrade Gravel depth: 6 Ft. 2 1 2 Ft. Classification (Private, A,B.C): Total Depth: Cased To: Total absorption area: Pipe material: Private 256'Ft. 256' Ft. 1 ,008 SQ. Ft. ASTM D3034 PVC _ )riller; Date Drilled: Static Water Level:Installer: Date installed; Alpine 10/16/~8 218' Ft. Spinell Homes 10/9/98 IPump Set at: ICasing Height Ab°ye Gr°und: TANK Yield: 30 GPM Ft. 2 I Ft. SEPARATION DISTANCES ~Septic [] Holding [] S.T.E.P. TO Septic Absorption Lilt Holding Public/Private Manufacturer: Capacity in gallons: From Tank Field Station Tanl~ ;eworLines Anchorage Tank 1 r 000 Number of Compartments: weu > 100 > 1 00 N/A N/A N/A Material: Steel Two Surf'ace >100 >100 N/A N/A ~/A LIFT STATION- N/A Water Lot > 5 ' > 10 ' N/A N/A N/A Size in gallons: I Manufacturer: Line :oundation >5' >10 ' N/A N/A N/A "Pump °n' level at: I''Pump °ff'' level at: High water alarm at: Curtain Non( on L¢)t Pump Make & Model Electrical Inspections performed by: Drain ,, BENCH MARK Remarks: Location and Description: Top of Front Deck Assumed Elevation: 100.0 F~, , , A Harala Inspections performed by, ... __ Dates. 1st Department of Hea&h a~d Human Services approval 72~013 (1/91) MOA 25 2 3 Permit No. SW980272 Page of MunicipaLity of Anchorage DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 · Anchorage, Alaska 99519-6650 e Telephone: 343-4744 On-Site Wastewater Disposal System and/or Well Inspection Report /ega~Description: Lot 9, Block 12, Mountain Park EstatespiDNo.: 017-391-48 _______~C7 C6.~ - o M2 c4 ~ c2 S2 ~ 1,000 Gallon Sl ~ Septic Tank Driveway F~Dom I% / Well Utility Easement PLAN AS-BUILT SCALE 1" = 30' S2 C4 M1 C5 C6 A 13 24 27 32 39 IB 5 23.0 2146.1 0~46.5 5/20.8 5! 53.5 Permit No. SW980272 Page ~ of '~ Municipality of Anchorage DEPARTMENT OF HEALTH .AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744 On-Site Wastewater Disposal System and/or Well Inspection Report Legal Description: Lot 9, Block 12¢ Mountain Park EstatespIDNo.: Sep. Tank 3' 12' .3' ~. .: ; 017-391 -48 94.5 Geotex, t i____l:e Fabric Drainfield Rock .,86.6 42' 75.0 42 ' '1 PROF]:LE, AS-BUT-LT · '": :: ." .: :'LZ-: ..A' '~.': '.i "':',' % :- i.'.?';:~: ;.-' t:' ~ :':..,:..:~;?::h-..' ...'.: '. ' ::-.': :'.., ' .' .i "[3'N''~ .. ~]E' "':.':'.".' · . .'. :. ." ,." ,. ~ · ' .~ ;"~'..'.:.~: '.~,r-~,:"'::\.~':..".' · ' ' .' '.'. .... :..;'.~ .', · " .: .',....' . · ..... ... /~/7~,,..~,, .:.~.~!.:~,,..: .~.,...._::.:~:,....:.~...........: :'.,',.:t?::~ ::. :"'-...!..:.'....E].s.: u.w ':..:-.... LOCATION/SKETCH: : · '-'?"'.':" :; .' ."- :" :;"::'".":: .'.' .. '.'.:':" : '"" '.'~l'i ;"oWNER:':":'"':'! "' ..... ' .... .' - ..... · . :...: ....'.:.-. .:.~..' '.': '.'.'-i- · · gePth.of.hoJe''~..4~rT' . ft . '. : .'' :~:B:.O.'~EHOI~'D'ATA:..' :"-....' .:"'.:' "": ,~ ': :.' :":.'::' '~.'D~ptl~'."D'ep'm"oL.¢a'si,§:~~t '/~ ./'/~_. /../~-'~" Mat~-ri~l'.'~'F~ ~,dlColoC" "~f ~':'" i':-"Fr~-n'."..:' '~.o , . ............ . ......... .. ..... .... ":: ":: ' ' ";: ":'::':'"Y" ':";:"':':" ?'."?:"'::;!':~"' ' "":' :' '-:?. ".' ::' ::. ' o'~PT'H"~0.S'T:.~I~i~'WAY'I~I~ 'L'EVEI~'"' ".L 2'" .'. ::~,...~'.,.'/~ ':".' .;:....~.::.'"......~-.,' ' 'o,~e: '..~;¢ 7//,- ;'7~ '.". ~ ,~-,.~-~.-.~'.~..,,. ~_;/~...t.¢ '...:. ' .". ,.;,~' .' ~-. · . '- :.. -. - . ' · '//". .'".,-. / -..' ~' .'. . '." . ':'.. ': .".':'..'" ""' ..:'. " . · ' .' . -." · ' ."'"":'i"' .,;, ~ .. '.' :: ~"". .... ' · .:..'.." .'.. ;."'..~..M'~I'HOD OF. ·DRILLING: ,~.ai~ rotar~ '" .r-] c~l~ e '~0o.. · -~~.. ~~:...~.:" '.' ~./_.:.,'.i: ~.,:~ ..~,u._.'. ...!" ...' :-.. ..... -' .:..... ":....: ..,:. · ......-I ~;~'...'. '~.: .-:.'..-..,.::= :'..~.~ .... :.:. ,.~... ':., .. ,...........~_. .....- :..,.. :. .. .. . ...."'.',,...' '..' ' ': ':..' ,,- ,,~. ~': b \,~..~ ::' ' :. '~':: , '.'~ ,:.":' .,": :.....USE:OF WELL.~'.,.~..ddmestib.' []_irrig~ti.o~' .r-1 ~or~t(~' . ...' !? :.: ":' '., ,':".. :'!:.,': .:..",-"':: ::'~.~*: ."/:' '~"':'Z:~:::".~::~.: i,-i'.?'"' ';:"?:':ii i':;.:" :.:i~;" : ~;ASI~~ ~:ric~. :,:-. '.':ft:: bia~.i-~: ': '.".'i6:'it~'~: ': ', . . ":'~.""1: ,."' %....,.¥:.':~ :.,.:...:.<~ ... ?.".:".':" '.'" '" ":'" .': .. '" · ' .' .:."'":" ,'~, · '. ' '.' · ': · . '. : .. ,~_~L .. : . .' ..... .':'~. ":: ,'":'.'";"- ' ':" "? "" :"'-,"." '::: · ,:S. "WF-L~.':INTAKEOI)~II~G'T~pE ',,~ Open'end E]'screehed :~.~'..' '-'~~' ........ ' ~ .(~:".'?: ...... '.': ' -~"-'"',."', .... ,/i~: .' .' '" ':'-"~'.,.~"...'..' · :' "" '.J':.:"' · ;. "'~' ' ..'..". ' ': .~ "" . .......... ' ..... -..:.": ", .~./:"..""~'~-,!.~...;:.~Z~)., ;'::.:-:::?:: ~'!:?:?"~"" .':'.'..i:: ..' -:...= ??:;~' '... '. '. ,,:'..:'::: i', ' '" :".:.:'" :. i.-. ':: '....:' '. '.:.-',: · .'t~~:~',~lr~"~.,.,~'.,-'.;.:. ;::.~,:,'~i.: :,,~ ~,~. -. D'e~thS of".o~enin~§:... ': · . .. '.to "' '.' ." .::. '~t"'.'"' '"" bJ~~~/-,,.,,,~,. · ~ ,~,., ....,...~ : . · ....... .. ~ ..........: ".~:~.;.' "":: ':~ ~i~":'(/~ '-:".'::' '..~ ~" ?' '::'~'-"L.:'. ':' ".'"".'::." ".:~:R'EEN:'f~'E:' ": ."" ' : '.:': "I~iam::_--.'" .~ '¢..'. ':.:;n:-::i.f~.....: .~-~' .:'~~ "..' .'" ':'- ' ~/-~:" ~'~.:' .',$lot~e~'h ~i~e:' ' : · '..Lei~gth;" · , :. _~/('. ,,/~",,,- : .. :':; .. :'.::.,': .': ../.,~ ,..: '~':;': ::: i.' ::: :"~,-...: :'.G~EL PACK'~I:Y~E'... · .. "':-','." '.'"':: '...'--i: ' '.., '...'..:". '. :. '.. ',,~ T~.!'~~~,: "'. ". '... : ' · ' '.' '..'i~ ~./~ F~:! ~.. [' ~-: ~:: ...'" Depth: · from., .. · . , .ft to ..... ft · ' : ". ;.IA, ]2 ~ ~.l.'~/,.l~: ¢.. . .. ...... . ' ' ' :" '' .' :' '',.."¢."..t.':.. ~:' .....,::v ..'.' Ii'~%OPMENT METHOD:'."~,'~"~'. :. :-,:' ' :'.. -- ' .... "i ;' -'.." ' ' '-." :"'-','. ~- ~'~"-¥n'tt!i '"..'. ' ' 'Duratio0:':' "'::'" ". .... '. "' : ".. - ' .' '. ~ '. · .' . ' . .. :':' ' .~-:" .:'.'~V~Ar~: ~"~....':~. '.'-~....~.. :..'. '...:.'..'.' ..... .,' .... ' ..... ". ..... . .."'' · ' '"::: '. ::'.:', :'.'.' ~."' , i .' '.PUMPING'I:~fY-I.~ANDyII~D:. ' ...... ~:' . · · - ' ' I~luh c pat y~t'~,hct;o~g~ · '~,~--~-' 'ft ~ftei ~' ' '- ' ' ' "' ~' "' -' - '.. · ~'".' ..... z' .... :... · ........ : .' .nfs Cumping ~%~'~' ' gpm · ·. .... :'.'g. eDt,.Heam~ ~,tmH~.u!, ~-~ .... h?.'~ ... ' .- · ....... ' ' , 7 '. · 7 '". .-:.% ... · .. . .. ....' ~'.:.::.' · : ;.;..L' '..'. ....;;.. .P. UMI~,'INTAKE DEP:EHy; ~-' '.~ f~' H0r~epowe~:; ' ". :.' · ' ........ ...: ;:v":.;. :"..: :.:.' ,.:~:..?/-;.'.i: .:.',::',:. ';: :'.~. D '~ N~=CTED .uPo~ c0~ 0,,' '" Pose-it' Fax Note 7671 Dat, "-.,~1%~ ,Jp~"# o~ · j l~t MUNICIPALITY OF ANCHORAGE Department of Health and Human Services On-Site Services Program 825 L Street, Room 502 P.O. Box 196650, Anchorage, AK 995~9-6650 (907) 343-4744 ON-SITE WASTEWATER DISPOSAL SYSTEM / WATER SUPPLY PERMIT Initial Date Issued: Jul 30, 1998 Expiration Date: Jul 30, 1999 Permit Number: 8W980272 Legal Description: MOUNTAIN PARK ESTATES BLK 12 LT 9 Design Engineer: 14.~c~-,~_~J'~-'~, ~'~L.¢',~ (L~_~-~ Owner Name: Spinell Homes Owner Address: 9210 Vanguard Drive Total Bedrooms: 3 Anchorage , AK 99507- Parcel ID: 017-391-48 Site Address: Lot Size: 22356 SQ. FT. Permit Bedrooms: 3 This permit is for the construction of: ¢~ Disposal Field ~J Septic Tank I~ Holding Tank ~ Privy Private Well [] Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AACS0 ). 3. The engineer must notify DHHS at least 2 hours prior to each inspection. Provide notification by calling (907) 343-4744 (24 hours). (Not required for a Water Supply Permit only). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received By: '~.~/~i~.. ~..~, '~ Date: July 21, 1998 Municipality of Anchorage Department of Heath & Human Services 825 "L" Street Anchorage, AK 99502-0650 Subject: Lot 9, Block 12, Mountain Park Estates Subdivision Septic System Design Impacts to Adjacent Properties Dear Onsite Services Engineer: The owner of Lot 9, Block 12, Mountain Park Estates Subdivision intends to construct a three bedroom home on the lot. We are therefore applying for a permit to construct a well and septic system on the lot to serve the house. The attached site plan and backup documentation identify the size and location of the new septic tank and absorption trenches designed to serve the house. It also shows the proposed location of the well and the 100' protective radius. Two testholes were placed on the lot at the locations shown. Poorly graded silty sand was encountered. Percolation tests completed indicated rates in excess of 40 minutes per inch. No groundwater was encountered nor was any measured during the monitoring period. We are therefore proposing to construct a deep trench system with 6' effective depth. Total length will be 84' with the distribution piping at 6' below the existing ground surface. The total depth of the system will be 12' below the existing ground surface. The surface of the lot is fairly flat with only a minor slope from east to west. The lot to the north is currently vacant with development on all remaining sides. No conflicts will exist between the new system and wells in the area. Lot 9, Block 12, Mountain Park Estates July 21, 1998 Page Two If the system is constructed as designed the following statements apply: The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. The system, if constructed as designed, will have no adverse impact on reserved space, either surface or subsurface, on any lots located in the area. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. SincereLy, Michael E. Anderson, P.E. Attachments Lot 1 ( Lo% 12 well sepl Lot 11 well not ? I well Lot 8 [ vacant septic ate& 1~ = 100' Lot 1 --I area AREA MAP SCALE 1" = 100' septic area Lot 1, Blk. 5 well '/ ALPINE DRIVE 'Alternate site ...... -'T~=~e ..... ~ ~,'~o0 ~,l'. B~droom.. ~..' septic Tank Nome-.. 'H1 2-42' 'Long--X---3-::'-~ide X '6' Effec,tive Depth Absorpti0~) Trenches k \ Proposed Well ............ 10' Utility Easement . LOT 9 .... SITE PLAN SCALE 1" = 20' LOT 9, BLOCK 12, MOUNTAIN PARK ESTATES DESIGN FACTORS: SYSTEM REQUIREMENTS: Three Bedroom Home Perc. Rate: 31 - 60 Min./Inch Application Rate: .45 GPD/SF Deep Trench System 1,000 Gallon Septic Tank 6' Drainfield Rock 3 Bedrooms X 150 GPD / .45 GPD/SF = 1,000 SF of Absorption Area 1,000 SF/12 SF/ LF of Trench = 84 LF Trench Length Therefore: Construct a Deep Absorption Trench System With Two Laterals Each 42' in Length with 6' of Drainfield Rock Beneath the Lateral. Distribution Pipe in Trench Placed at 6' Below the Original Ground Surface. Natural ~/I ~-~ ' ' Backfill~ 310'1 TYPICAL DEEP TRENCH SECT]ON (NO SCALE) NOTE: Grade Area Over Trench to Drain Away. Minimum 3' of Cover over Septic System. Maintain 10' Separation From Lot Line. PERFORMED FOR: Munici!~atity of A~chomge DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alasl(a 99502-0650 SOILS LOG -- PERCOLATION TEST Spinell Homes LEGAL DESCRIPTION: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Block 12. Mtn. Park Estates TESTHOLE NO. Bottom of Hole Townsl~ip. Range. Sec~on: SLOPE L WAS GROUND WATER ENCOUNTERED;' SITE PLAN I I IF YES. AT WHAT DEPTH;' M~umrmg? / PERCOLATION RATE ~'~'"' {m,nute~/mcn) PERC HOLE DIAMETER ~ II PERFORMED FOR: Municipality o! Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alasi(a 99502.0650 SOILS LOG -- PERCOLATION TEST Spinell Homes Lot 9, Block 12r LEGAL DESCRIPTION: Township, Range, SectJon: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20- COMMENTS ~Mtn. Park TESTHOLE NO. 2 Bottom of Hole Estates SLOPE WAS GROUND WATER SITE PLAN ENCOUNTERED;' /~/ $ IF YES, At WHAT J 0E DEPTH? ~ P E _~_~ m W~ 14~ / ~"' ?/~.wl/~._ , ..- & Gro~ Net OeOtn to I Net Reading Oa~e Time Time WaterI PERCOLATION RATE ~:~ (m,n~e~,ncn) PERC HOLE DIAMETER TEST RUN BETWEEN 7 FT AND <~ FI' ON-SITE WASTEWATER DISPOSAL SYSTEM CONSTRUCTION AND MATERIAL SPECIFICATIONS SUBJECT: LOT 9, BLOCK 12, MTN. PARK EST. SUBDIVISION GENERAL: 1. The scope of this project includes the procurement and placement of a new 1,000 gallon septic tank. It also includes the construction of 2 new 42' long by 3' wide by 6' effective depth absorption trenches at the location shown on the site plan. The distribution piping must be placed at 6' below the original ground surface. Total depth of the trenches will be 12' from the original ground surface. Grade finished surface to drain away from trenches. 2. Construction shall be in accordance with the approved site plan, design drawings, Municipal Permit with any special provisions or conditions, and all applicable State and Municipal Wastewater Disposal Regulations. 3.-i"he Contractor shall be responsible for obtaining all underground utility locates and for the layout of the septic system and verification of the location of all lot lines. 4. Unless specifically agreed otherwise, the contractor shall be responsible for final grading areas subsequently depressed from soil settling. Property owner shall be responsible for revegetation of affected areas unless specifically agreed otherwise. 5. Contractors installing wastewater disposal systems must be certified by the Municipal Department of Health and Human Services for system installations. Owners installing their own systems must receive prior approval from D.H.H.S. before beginning system installation. SEPTIC TANK INSTALLATION A new 1,000 gallon septic tank must be procured from an approved source and installed at the location shown on the plans. Lot 9, Block 12, Mtn. Park Est. July 21, 1998 Page Two 2. A septic tank is to be constructed by a certified septic tank manufacturer. Construction shall include two 4" cleanouts for pumping access. 3. The septic tank shall be sufficiently bedded to prevent settling or shifting of the tank. 4. All standpipes on the septic tank shall extend a minimum of 12 inches above final grade. 5. Tanks installed without 4' of cover shall have a minimum of 2" of direct burial insulation. 6. A foundation cleanout shall be installed one to four feet from the building foundation. Two cleanouts are required between the tank and the drainfield. 7. Final grading over the tank shall be such that a positive slope exists away from the septic tank. DRAINFIELD CONSTRUCTION: 1. The drainfield shall be constructed to the dimensions shown on the design. The bottom of the trench shall be within 2" of level. 2. Distribution piping must be placed level with perforations down atop alevel bed of drainfield rock. Rock should then be placed over the pipe to provide a minimum of 2" of cover. 3. A silt barrier or geotextile fabric must be placed between the drainfield rock and the natural soil backfill. 4. Monitor tubes must be 4" in diameter and installed at the locations shown on the design. The portion below ground must be perforated. Lot 9, Block 12, Mtn. Park Est. July 21, 1998 Page Four 5. A permeable geotextile fabric (Typar, Mirafi or equal) must be installed between the final drain rock layer and the native soil layer. 6. All drain rock shall be .5" to 2.5" in diameter with less than 3% passing the #200 sieve. INSPECTIONS: A minimum of two inspections are required by Municipal Ordinance. These inspections must be conducted under the supervision of a professional engineer registered in the State of Alaska. The first inspection must be conducted after the excavation of trenches, beds or pits and before the installation of any gravel. A septic tank may be set in place, but may not be backfilled. The second inspection must be conducted after the placement of the geotextile fabric, gravel, distribution piping, standpipes, cleanouts and insulation. No backfill should be in place at the time of inspection. Contractor shall provide a copy of all field survey layout and construction notes for use in preparing the certified as-built of the completed system. Lot 9, Block 12, Mtn. Park Est. July 21, 1998 Page Three 5. Contractor shall verify the septic tank and drainfield are a minimum 100' away from any private water wells in the area, 150' from a Class "C" Well or 200' from any community well. 6. Direct bury insulation must be placed over the distribution system if less than 3' of backfill depth is available. Finish grade over the trench must be mounded to prevent settlement or depressions. 7. Grade area surrounding the absorption trenches to drain away. 8. A minimum 2' of accepting soil is required below the drainfield rock for a 5' wide trench. Contractor shall verify this condition prior to placement of the rock. All pockets of unacceptable materials must be removed and replaced. MATERIAL SPECIFICATIONS: 1. Septic tanks must be constructed by a Municipally approved septic tank manufacturer. 2. The following pipe materials are approved for use in septic system installations in the Municipality of Anchorage: Cast Iron (perforated and solid), ASTM D3034 or P.V.C. (perforated and solid), ASTM F810 or H.D.P.E. (perforated, but not solid) and ASTM D2662 or A.B.S. (perforated and solid). 3. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Co. Styrofoam HI or equal). 4. Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Fernco, or equal). 1. GENERAL INFORMATION: Complete legal description Mountain Park Estates; Block 12 Lot 9 Location (site address) 12801 Mountain Place*Anchorage, AK 99516 Current Property owner(s) Lorraine Kastner Day phone 440-9813 Mailing address 12801 Mountain Place *Anchorage, AK 99516 Real Estate Agent Day phone 2. TYPE OF DWELLING: ® Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 3 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well ® Individual Individual Water Storage ❑ Holding Tank ❑ Community Class Well ❑ Community_ ❑ Public Water System ❑ Public Sewer . WaiverNariance requestlor: Distance: Received'by: Date: COSA to be released to the engineer, unless otherwise requested by the engineer. COSA Fee Waiver Fee $ Date of Payment V-2 Date of Payment Receipt Number Q� 7� �� ' Receipt Number COSA# 105c%q % 369 Waiver# 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm: Garness Engineering Group, Ltd (GEG) Phone: 907-337-6179 Address: 3701 East Tudor Road, Suite 101- Anchorage, Alaska 99507 Engineer's Printed Name: Jeffrey A. Garness Date: u fEr In conducting this evaluation, GEG provided an engineering evaluation of the well and/or septic system in accordance with the guidelines and regulations established by the Municipality of Anchorage and industry practices. The reported results describe the condition of the system/s on the date/s of the evaluation. Separation distances were measured to readily identifiable features. Hidden defects or encroachments may exist that were not identified during the evaluation. The operational life of all wells and septic systems depend upon a variety of variables, including but not limited to, soil conditions, groundwater levels (that may fluctuate during the year), quality of construction (materials and workmanship), and the water usage of the family utilizing the system/s. These conditions can vary, and are outside the control of GEG. Satisfactory test results do not guarantee future performance of the system/s; therefore, GEG makes no warranty (express or implied) regarding the future performance of the well or septic system. GEG makes no representation whether an alternative well or septic system can be installed on the property in the event either of the current systems fail to perforin adequately in the future. The content of this report is for the sole benefit of the person/party that retained GEG to perform the evaluation. Reliance upon the information provided in this report by any other person or party (including subsequent property purchasers) is not authorized, nor will it confer any legal right whatsoever. 6. DSD SIGNATURE WN System #1 Approved for 3 bedrooms System #2 Approved for bedrooms Disapproved Conditional approval for '\'PtALITY6 �6f bedrooms, with the following stjs: -fie ri, r 1 Original Certificate The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist Septic System Advisory Well Flow Advisory COSA blue sheet 10-10-12.doc Nitrate Advisory Arse.isory Other ;r L /. .... ........ ........ J ?�9_ f•'�CEE A. Go ess.: 953 aa `cwt v'•� or essic�q #AECC884 '\'PtALITY6 �6f bedrooms, with the following stjs: -fie ri, r 1 Original Certificate The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist Septic System Advisory Well Flow Advisory COSA blue sheet 10-10-12.doc Nitrate Advisory Arse.isory Other Legal Description: Mountain Park Estates; Block 12, Lot 9 If more than 1 septic system on lot: COSA Checklist # of A. WELL DATA ❑ Well log is filed with Onsite (or attached) Date drilled ""619e Total depth 256 ft Cased to 256 ft ❑ Sanitary seal is functioning correctly ❑ Wires are properly protected Casing height (above ground) 18+ in. Date of flow test for COSA 7/12/19 Static water level at beginning of test 220.6 ft. Comments B. TANK DATA Age of tank(s) 21 years Tank type/material seplidsteel Measured operating fluid level in septic tank 52 ❑ Standpipes/foundation cleanout per record drawing Date of pumping 5/24/19 D. ABSORPTION FIELD DATA Parcel ID: 017-391-48 Structure served by this system Well production at time of test 5.0+ gpm Water storage tank volume n/a gallons Well disinfected for coliform test? ❑ Yes ❑ No ❑ Coliform bacteria is Negative Nitrate mg/L Nitrate less than MRL (ND) Arsenic ug/L (Arsenic less than MRL (ND) Collected by GEG, Ltd. _ Date of Sample. 7 ci C. LIFT STATION ❑ Required maintenance completed Age of lift station years Lift station material Which system tested (date installed) 1998 Adequacy test date 7/12119 ❑ ALL stand pipes.present per record drawing Results ❑✓ Pass For 3 bedrooms Total measured depth from grade "13.25 ft (max) Fluid depth prior to test 31 in Measured depth to pipe invert from grade 6.5+ ft (min) Water added 635 gal ❑ N/A — pressurized field 50 New depth in ❑ Monitor tubes go to bottom of effective. If not, stateElapsed 150 depth into effective "' time min Q Code -required soil cover over'field Final fluid depth 42 in ❑ System presoaked Absorption rate 450+ gpd (Required if vacant for greater than 30 days prior to Any rejuvenation treatment (past 12 months) no date of test) Gallons introduced n/a gallons If yes, enter date - Comm ents/Deficiencies: Tested west trench only, East trench had 5 inches of liquid in it. "To bottom of MT in West trench. —East trench MT 4.75'& West trench MT 5.66' COSA Checklist yellow sheet E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well) Septic Tank/Lift Station on Lot > 100' ❑ Yes if No *5+ Community Sewer Manhole/Cleanout > 100' Q Yes if No ft 2] Yes if No ft Neighboring Tank > 100' Yes if No ft Private Sewer/Septic Line > 25' 0 Yes if No ft Absorption Field on Lot > 100' Q Yes if No ft Holding Tank > 100' 0 Yes if No ft Neighboring Absorption Fields > 100' Water Service Line > 10' El Yes Animal Containment > 50' 0 Yes if No ft ❑r Yes if No ft if No ft Manure/Animal Excreta Storage > 100' Community Sewer Main > 75' Z Yes if No ft ❑✓ Yes if No ft From Septic/Holding Tank on Lot to: (Please enter distances if less than required) Building Foundations > 10' ❑ Yes if No *5+ ft Surface Water > 100' Q Yes if No ft Property Line > 5' v Yes if No ft Wells on Adjacent Lots: if No Absorption Field > 5' ❑� Yes if No ft Private Wells > 100' 0✓ Yes if No ft Water Main > 10' ❑r Yes if No ft Community Wells > 200' ❑✓ Yes if No ft Water Service Line > 10' El Yes if No ft If septic tank is under driveway comment below From Absorption Field on Lot to: (Please enter distances if less than required) Building Foundation > 10' Q Yes if No ft If absorption field is under driveway comment below Property Line > 10' Yes if No ft Wells on Adjacent Lots: Water Main > 10'❑ Yes if No ft Private Wells > 100' Q Yes if No ft Water Service Line > 10' Yes if No ft Community Wells > 200' El Yes if No ft Surface Water > 100'❑ Yes if No ft F. ENGINEER'S COMMENTS *Met code at time of installation (6.7' from ST1 to foundation) G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. COSA Checklist yellow sheet �F 497........... Garn ss 44�a p�ofess�o�oo ##AECc884 ��D��oOoo 16 Septic Tank Advisory Certificate of On -Site Systems Approval #OSC191369 Subdivision: Mountain Park Estates B12 lot 9 Starting at 20 years of age the MOA issues Advisory's for steel septic tanks. The septic tank for this property is 21 years old. Typical replacement costs range from $6,000 to $9,000. This advisory must be attached to all copies of the subject Certificate of On -Site Systems Approval. This is an example of what the metal of a 20 year old steel tank MAY look like. P-501 MOUNTAIN PARK ESTATES SUBD. LOT 9, BLOCK 12 22,353 S.F. SEt 5�g' X $0" R6!LSA 2 C- '-RP 51 egcc e -°v -t05 Og 10\51A°I N 89059'00"E 196.08' gE�ttSEp l0rl°`4a 4�4Vf:9 lPt i-°P`'rF'Q'S' �� FINAL STRUCTURE AS -BUILT .AS -BU I L T I hereby certify that I have surveyed the property depicted above and that no GASTALDI LAND SURVEYING encroachments exist except as Indicated. Jeff A. Gastaldl, R.L.S. It Is the responsibility of the owner to 4726 West 88th Ave. - determine the existence of any easements, Anchorage, Alaska 99302 covenants or restrictions which do not PHONE 248-5454 appear on the recorded subdivision plot. Under no circumstances should any data GRID DATE hereon be used for construction or for 2838 11/30/98 °stablishing boundary or fence lines. F. B. J08 N0. ANCHORAGE RECORDING DISTRICT, ALASKA 98-20 MPES12 **1"aN114V *tOF .. ,q4jw �1 i �4;� '• *• 9♦ . 49TH •••. ? ...........� Je a astoldi ...o Aff i ` e LS -6091 : 1;J" 40 e °a �•••........••• eJ"! I'M ral %**,* 1 1I-30' 4,�a**o I I x x o x I o 6 o I c 65.1'qbEXISnNG I U, RFP. CANTNG64.9. aa I U) MSEPnC TMEW LOT 932.(Y o I� I Z GRAVEL DRIVE N WELL I � I N 89059'00"E 166.03' 0 M MOUNTAIN PLACE gE�ttSEp l0rl°`4a 4�4Vf:9 lPt i-°P`'rF'Q'S' �� FINAL STRUCTURE AS -BUILT .AS -BU I L T I hereby certify that I have surveyed the property depicted above and that no GASTALDI LAND SURVEYING encroachments exist except as Indicated. Jeff A. Gastaldl, R.L.S. It Is the responsibility of the owner to 4726 West 88th Ave. - determine the existence of any easements, Anchorage, Alaska 99302 covenants or restrictions which do not PHONE 248-5454 appear on the recorded subdivision plot. Under no circumstances should any data GRID DATE hereon be used for construction or for 2838 11/30/98 °stablishing boundary or fence lines. F. B. J08 N0. ANCHORAGE RECORDING DISTRICT, ALASKA 98-20 MPES12 **1"aN114V *tOF .. ,q4jw �1 i �4;� '• *• 9♦ . 49TH •••. ? ...........� Je a astoldi ...o Aff i ` e LS -6091 : 1;J" 40 e °a �•••........••• eJ"! I'M ral %**,* 1 1I-30' 4,�a**o Parcel I.D. # MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & HUMAN SERVICES Division of Environmental Services On-Site Services Section P.O. Box 196650 Anchorage, Alaska 99519-6650 343-4744 CERTIFICATE OF HEALTH AOTHORITY APPROVAL FOR A SINGLE FAMII.:Y DWELLING 017-391-48 HAA# I GENERAL INFORMATION Complete legal description Lot 9, Block 12~~ Mountain Park Estates Location (site address or directions) Alpine Drive at Mountain Place Property owner Mailing address Lending agency Mailing address Spinell Homes 9210 Vanguard Drive Day phone 344-5678 Anchorage¢ AK 99507 Day phone Agent Address Day phone Unless otherwise requested, HAA will be held for pickup. Three ( 3 ) NUMBER OF BEDROOMS: TYPE OF WATER SUPPLY: individual well Community well NOTE: XXX Public water If community well system, provide written confirmation from State ADEC attest- ing to the legality and status of system. 4. TYPE OF WASTEWATER DISPOSAL: NOTE: XXX Individual on-site Holding tank Community on-site Public sewer If community wastewater system, provide written confirmation from State ADEC attesting to the legality and status of system. 72-025 (Rev. 1/91) Front MOA ~21 STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health Authority Approval application shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verifythat based on the information obtained from the Municipality of Anchorage flies and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on the date of this inspection. Name of Firm ~nd~rson Engineering Phone 522-7773 Address P.O. Box 240773 Anchorage, AK 99524 Engineer's signature ¢t~ ~_~ Date 3/10/99 DHHS SIGNATURE ~ Approved for ,.~ Disapproved. Conditional approval for bedrooms. bedrooms, with the following stipulations: Additional Comments The Municipality of Anchorage Department of Health and Human Services (DHHS) issues Health Authority Approval Certificates based only upon the representations given in paragraph 5 above by an independent professional engineer registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHHS do not conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 72-02~ (Rev. 1/91) ~ck MOA RECEIVED Municipality of Anchorage MAR 1 I 1999 DEPARTMENT OF HEALTH & HUMAN SERVIC~{~NIClPALiTY OF ANCHO Environmental Services Division ENVIRONMENTALSERVICES [; 825 L Street, Room 502 · Anchorage, Alaska 99501 · (907) 343-4744 Health Authority Approval Checklist Legal Description: A. WELL DATA Lot: 9~ Block 12, Mountain ParcelhD.: 01 7-391 -48 Park Estates Well type. Private Log present (Y/N) Total depth 256 ' SanitaW seal (Y/N) If A, B, or C, attach ADEC letter. ADEC water system number Y Date completed 10/16/98 Cased to 256 ' Casing height (above ground) y Wires properly protected (Y/N) 2I FROM WELL LOG Date of test 10/16/98 218' 30 Static water level Well production g.p.m. WATEP, SAMPLE RESULTS: Coliform 0 Nitrate ATINSPEOTION Date of sample: 3 / 4 / 9 9 B. SEPTIC/HOLDING TANK DATA Date installed 1 0 / 9 / 9 8 'lank size _ 1 , 0 0 0 Foundation cleanout (y/N) Date of Pumping New. ~ .*-.!. "~:~ /...~:. C. ABSORPTION FIELD DATA [:)ate installed 1 0 / 9 / 9 8 .178 mq/L Other bacteria 0 ColleCted by: ~ MEA g.p.m, High water alarm (Y/N) Length 8 4 ' Width 3 ' Effective absorption area. 1 ~ 0 0 8 Number of Compartments __.2 . Cleanouts (Y/N) N Depression (Y/N) N Pumper Construction Soil rating (g.p.d./ft2 or ft2/bdrm) .45 Gravel thickness below pipe S]~onitoringTube present (y/N) Y Date of adequacy test New ¢'.ons'h. Results (Pass/Fail). Fluid depth in absorption field before test (in.); System type Deep Trench 6 ' Total depth 1 ¢" .. · Depression over field (Y/N) ~ For Immediately after gal, water added (in,): Absorption rate = .g.p.d. If yes, give date N bedrooms Fluid depth (ins) Minutes ater: Peroxide treatment (past '12 months) (Y/N) 72-026 (Rev. 3/96)* D, LIFT STATION None on Lot Date installed Manhole/Access (Y/N) High water alarm level at* Cycles tested E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Size in gallons "Pump on" level at* *Datum Septic/holding tank on lot Absorption field on lot Public sewer main Sewer/septic service line On adjacent lots > 100 ' On adjacent lots > 100 ' Public sewer manhole/cleanout Lift station N / A SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Foundation > 5 ' Property line > 5 ' Water main/service line SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line > 1 0 ' Building foundation > 1 D ' Surface water > 1 0 0 ' Curtain drain None on Lot ENGINEER'S CERTIFICATION I certify that I have determined thru field inspections and ravia in conformance with MOA HAA guidelines in effect on this date, Signature ~t~, ~'~..~ ~.~ Engineer',s Name Michael F,. Anc]~r.~nn: p: ~.. Date Absorption field > 5 Wells on adjacent lots "Pump off" level at* >100' Water main/service line > 25 ' Driveway, parking/vehicle storage area > 2 5 ' Wells on adjacent lots > 1 (~D ' HAA Fee $. ~ ~D Date of Payment Receipt Number z74 72-026 (Rev, 3/96)* Waiver Fee $ Date of Payment Receipt Number N Sd BD CERTIFICATE OF OWNERSHI~P AND DEDICATION } 23,570 ~E SURVEYOR'S CERTIFICATE ~5. I, MAURICE R OSWALD , PROFESS[0N~~ AND.CORRECT REPRESENTATION OF LANDS ACTUALLY ~OTARY h< ACKnOWLEDGMENt SUBSCRIBED AND SWORN TO BEFORE ME THI~ ~Y COMMISSION EXPIRES: ~y ~w~/_, /¢~ SIGNATURE ACCEPTANCE OF DEDICATION ANCHORAGE HEREBY ACCEPTS FOR PUBLIC USES AND FOR PUBLIC PURPOSES THE REAL PROPERTY DEDICATED ON THIS PLAT. INCLUDING BUI NO1 LIMITED TO THE EASEMENTS. RIGHTS-OF-WAY. ALLEYS. ROAD~AYS. THORODGH~E~RES AND PARKS SHOW) HEREO~, DATED~rA~HORAGE. ALASKA. THIS ~&~"lDAY OF .a.~,~ ,~,~: - MOUNTA N PARK ESTATES SUBDIVISION LOTS IA&2A BLOCK 12 · -/t~-~ DICtdlNCXDDI' C~U~LD.WkLCH LCC DRAWN SLH R-BIER E 18-04 SNO 5218 FIELDBOdK BBB-B? 105-68