Loading...
HomeMy WebLinkAboutNARNIA Lots 1 & 2 Plat# 93-113 S-9342 PERFORMED FOR: Munlclpallly of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST 9 10 11 12 13 14 15 16 17 18 19 2O COMMENTS Township, Range, Section:'"~'~-~t...j . '~'~..\ tCJ i SLOPE SITIE PLAN WAS GROUND WATER ,. ) ENCOUNTER ED? ~'~ c::' S IF YES, AT WHAT DEPTH? p E Deplh Io Water Aller ~oniloring? "~ Date: Reading Date Gross Net Depth to Net Time Time Water Drop PERCOLATION RATE '~ (m~nutes/inch) PERC HOLE DIAMETER TEST RUN BETWEEN ~ F'f AND____'¢~ F T PERFORMED BY: S & S ENGINEERING ~ ~ CERTIFY THAT THIS TEST WAS PERFORMED IN 17034 Eagle River Loop Road No 204_A ACCORDANCE W~-a~CLJ-k~T~,i~J~aM~AL GUIbELINEt5 IN EFFECT ON THIS DATE, DATE: \ (~>."~..,~ ~¢~t, ~ PERFORMED FOR: Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST \ DATE P~RFOm~EO: \ 5 6 ~fvl 8 9 10 11 12 13 14- 15- 16- 18- 19- 20- Township, Range, Section: "'~'~,~---~ r,~ SLOPE SITE PLAN WAS GROUND WATER ENCOUNTERED? S L IF YES, AT WHAT O DEPTH~ p E Deplh 10 Water Alter Reading Cross Net Depth to Net Date Time Time Water Drop PERCOLATION RATE '~' (mmutesfinchJ PERC HOLE DIAMETER TESTRUN ~ETWEEN__~ FT AND __~' FT COMMENTS $ & $ ENGINEERING PERFORMED BY: ~ '70:~4 :'~agle River Loop ROa~ ~O~L~~ CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STrAfE A'I~I~!- GUIDELINES IN EFFECT ON THIS DATE. DATE: \ ~'"'2.~ ~"~"'-" MUNICIPALITY OF ANCHORAGE MEMORANDUM DATE: January 28, 1993 TO: FROM: Department of Economic Development and Planning Zoning and Platting Susan Oswalt, On-site Services Department of Health and Human ,Services SUBJECT: S-9342 - Narnia Subdivision DHHS will support the proposed plat with the following conditions: We will require that the existing undocumented sewer system (which is in failure) be upgraded prior to final plat. This department will verify that upgrading is completed no later than June 15, 1993. Water monitoring will be required on all test holes through May, 1993. The proposed well on Lot 2 must be relocated slightly to accommodate additional reserve area needed for this lot. SO/ljm RECEIVED D Mu~.~c,pal,~¥ et Anchorage ept, Health & Human Servlcea 3 4 5 53.~9 345 0927 HEALTR AUTHORITY APPROVALS SEWER & WATER MAIN EXTENSIONS SEWER & WATER INSPECTION ENGINEERING STUDIES AND REPORTS WELL INSPECTION & FLOW TEST SITE PLANS ROAD DESIGN SOIL TEST PERCOLATION TEST STRUCTURAL & MECRANICAL INSPECTIONS ON SITE WASTEWATER DISPOSALSYSTEM DESIGN [,,q t/' ' ROBERT SHAFER. P E ROGER SHAFER, P.E January 8, 1993 CIVIL ENGINEERS (907} 694-2979 FAX 694 !211 Municipality of Anchorage DEPARTMENT OF HEALTH AND HUMAN SERVICES 825 L Street P.O. Box 196650 Anchorage, Alaska 99519-6650 At~entio n: RECEIVED dAN 8 1995 Municipality of Anchorage DepL Health & Human Services susan Oswalt ¢ REFERENCE: SW~, SE~, NW~, SW~, Section 50, FI5N, R/W, S.M. Proposed Narnia Subdivision Dear Susan, At the request of the property owner and per our telephone conversation on I/7/93, we visited the referenced property to further investigat~ the existing s~ptic system. The septic system is apparently undocumented, however, the current owner says the previous owner claims the system consists of a "1000 gallon septic tank with a leachfield trench". Inspection of the property found 3 existing septic pipes. The standpipe closest to th~ house appears to be a septic tank cleanout. Approximately 1100 gallons of wastewater was pumped from the tank. The second standpip~ is a 4 inch PVC cleanout in the s~w~r line leading from th~ septic tank to the leaehfield. The third pipe within the system is apparently a l~achfield monitoring tube. Inspection of this pip~ found a liquid l~vel approximately 2 ft. from the ground surface. Approximately 200 gallons of ~ffluent was pumped from this pipe. Th~ s~ptic system s~rving the property apparently consists of a septic tank/leachfield type system. Test hol~s excavated on the property in October, 1992 suggested no groundwater encroachment existed at that tim~. However, an encroachment may exist on the bedrock. Due to the unusually high liquid level within the leachfield monitoring tub~, I susp¢cl the system is in a state of failure with little absorption capacity. However, inspection of the area adjacent to the leachfield did not reveal any surfacing effluent or other obvious signs of an eminent health hazard. It should also b~ noted that in the event the septic system do~s overflow, the septic tank cleanout is accessible for periodic pumping as necessary to minimize health hazards until the septic system is upgraded. 17034 EAGLE RIVER LOOP, SUITE 204, EAGLE RIVER, ALASKA 99577 Pag~ ~wo SW~, SE~, NW~, SW~, S~ction 30, T15N, RIW, S.M. Proposed Narnia Subdivision January 8, 1993 If you hav~ any questions, or r~quir~ additional information for your r~vi~w, pl~as~ contact us. Sincerely, ROGER J. SHAFER, P.E. R JS / tv 35O /AZ~ T RECEIVED JAN 6 199,5 Municlpahty of Anchorage Dept, Health & Human 8er~i~e~ Anchora[Te Heco£~ ; Di$1rict/ Anchoz'age~A/aska 17eg/'slorod L.~nd Surveyor PO. Box Anchora£e~ Alaska 99511 (907)Z45-092~