HomeMy WebLinkAboutNEVILLA PARK Block 1 Lot 23 FHA Form 2573 Form Approved Rev. July 1958 FEDERAL HOUSING ADMINISTRATION Budget Bureau No. 63-8296.8 HEALTH AUTH¢)RITY APPROVAL INDIVIDUAL WATER SUPPLY AND SEWAGE DISPOSAL SYSTEM PART I,--TO BE COMPLETED BY FHA ~NSUmNG OmCE ~O~O~ s~m~ NO. Anchorage, A].aska ~aska S%a'be B~k ~[L-011[03-203 MORTGAGOR OR SPONSOR PROPER~Y ADDRESS Larry Hasc~e 812~ 2nd Avenue Last 5USD[V[S~ON NArC BLOCK NO. COT NO. Nevilla Park ]. 23 Can ohio or other area be made into ~ ~ew J~sta]]at~o~ oddltional bedrooms? BASEMENT LIVING UNITS BEDROOMS BATHS --- (if Yes, how many?) ~ 3 2 ~ Yes ~ No I ~ Yes ~ No WA~ER SUPPLY BY: SYSTEM DESIGNED FO~ Public system [] CommuniW system~LJ Individual ~o. o~ ~.~ o~.,.~ o,s.osat SEW~E DISPOSAL BY: ~ ~blic system [] Community system ~ Indiviciual ~ [~ Yes ~ No PART II.-~TO BE COMPLETED BY HEALTH DEPARTMENT HEALTH D~PART~EN? INSPECTOR'S SKETCH ~ZZZZ_ ZZZZ~ :ZZZZ~ -ZZZ[ ZZ_ZZ ZZZZZ ZZZZZ ZZZZ._ ZZZZZ It is the opinion of the ~ S~ate ~ County ~ Local Department of Heakh cha~ this individual water-supply system ~ is ~ is nec satisAc~ory as a domestic water supply for the subject properw. PUBLIC It is the opinion of the ~ Sta~e ~ Conncy ~ Local Department DC Health chac chis individual sewage-disposal sys- tem with proper maintenance: ~ Can be expected ~o function satisAccorily, and ~ Cannot be expected to funcdon satisfactorily likely to~ an i nitar~?ndition DATE Q SION~ Sept. 8~ 1970 / .> Sanitarian NOTE:~-,/.~ hoe ~ authorlty should complete the appropriate opinion statement date, signature in the spaces provided. / Use of ~he ~ove grid for Health Dep~rtment Inspector's sketch as well as use of ti~e bock of this form is ut tire option of the health authd~ PART III,~FOR USE OF FHA OFFICE TO THE CHIEF UNDERWRITER; [ h~ve reviewed ~he ~ore~oh~ ~nd the pertinent ~HA CompH~nce Inspe~don Report, ~nd recommend ~h~t'~he Individual water-supply system be considered [] Acceptable ~ Not Acceptable Sewage dis~sal be considered ~ Acceptable ~ Not Acceptable. DATE SIGNATURE ~ CHIEF ARCHITECT ___ ~ ~EPUTY FO~.CHI~E_F A~CHIT~ HEALTH AUTHORITY APPROVAL INDIVIDUAl, WATER SUPPLY AND SEWAGE DISPOSAL SYSTEM FHA Form 2573 Rev. July 1958 GR 'ER ANCHORAGE AREA BOROL' 'H HEALTH DEPARTMEN? 327 EAGLE ST. ANCHORAGE, ALASKA 99501 279-2511 INSPECTION REPORT ON-SIi'E SEWAGE DISPOSAL SYSTEM NAME PHONE MAILING ADDRESS SEPTIC TANK: DISTANCE FROM WELL LIQUID CAPACITY SEEPAGE SYSTEM: NUMBER OF MATERIAL COMPARTMENTS _GA,~NS. INSIDE LENGTH INSIDE WIDTH LIQUID DEPTH __ NUMBER OF PITS / LINING MATERIAL__ NEAREST LOT LINE /~"'~ / OUTSIDE DIAMETER / '~ OR WIDTH /ti/ LENGTH / ~'~ / , , DEPTH DISTANCE FROM WELL ~) , BUILDING FOUNDATION TOTAL EFFECTIVE ABSORPTION AREA (WALL AREA) '"~ ''~' '~ SQ. FT. TILE DRAIN FIELD: TOTAL LENGTH DISTANCE FROM WELL FOUNDATION NEAREST LOT~U~:J~F~ OF LINES -- NUMBER OF/'; :D~t~IANC-,E--BETWE~N'TI~-E'-S-- TRENCH WIDTH ........ IN, TOTAL EFFECTIVE ABSORPTION AREA __SQ. FT. LENGTH OF EACH LINE DEPTH: TOP OF TILE TO FINISH GRADE DEPTH OF FILTER MATERIAL BENEATH TILE IN. ABOVE TILE____ WELL: TYP , DEPTH ,BUILDING FOUNDATION SAMPLE , NEAREST NEAREST SEPTIC SEEPAGE OTHER LOT LINE , SEWER LINE ., TANK , SYSTEM , CESSPOOL , SOURCES__ DIAGRAM OF SYSTEM DISTANCES: DATE APPROVED ~ HEALTH AUTHORITY GA~ B-HD-2 GREATEh ANCHORAGE AREA ~.)ROUGH liEALTIt DEPARTMENT 327 Eagle St. Anchorage, Alaska 99501 279-2511 Case No. ~'~/ . SEWAGE DISPOSAL SYSTEM - APPLICATION & PERMIT NAME OF APPLICANT RESIDENCE ADDRESS LEGAL OESCRIPTIONr Z,¢ ?' D.~j Z._;z~,~'~ / i~/~' APPLICATIONT0 INSTAkL: SEPTIC TANK ~,SEEPAGEPIT~~,DRAIN FIEkD TO SERVE THE FOLLOWING FACILITY '~/ FINANCED THROUGH ~[_-/~'~ TO BE INSTALLED BY ~ & /~' · PERCOLATION TEST RESULTS ~-z~ ~-~q ANTICIPATED DATE OF COMPLETION ,'/-/~'1 ,.~C/'I/~ MAILING ADDRESS~/¢', ~,~, , PHONE NO,_'-~"~ LOCATION OF INSTALLATION_2/~? ~C~' ~'c3, c? ~ ,OTHER_ BELOW TO BE FILLED OUT BY HEALTH DEPARTMENT THIS IS TO SERVE AS_ /v)~, / ,r.~ ',~(:J'; ~.~;k,PERMITTO INSTALLA ~"~ AS DESCRIBED BELOW. SIZE OF UNITTO BESERVED _. SEPTIC TANK SIZE ~TYPE ~.~ .SEEPAGE AREA DIAGRAM OF SYSTEM DISTANCES: ~ ' -~HEALTH AUTHORITY -- ,_,~..~o ,~,~.~. ~ ~/&;7~ 7a ~ I certify that I am familiar with the requirements of Greater Anchorage Area Borough Ordinance No. 28-68 and that the above described system is in accordance with said code. f / ~... ' _ . . GREATER ANCHORAGE AREA BOROUGH 2207 MoRAE ROAD ANCHORAGE~ ALASKA 99§03 272--1577 DEPARTMENT Of PUBLIC WORKS June 23, 1970 GA!\$ Ilealth Department 327 Eagle Street Anchorage, Alaska 99501 Gentlemen: SAiiITARY SEWER SERVICE - NEVILL~ PAR',< SUBDIVISION LOT 23, BLOCK 1 This is to confirm that the Greater Anchorage Area Borough Department of Public Works has set up an Improvement District in the East Muldoon Area which includes Nevilla Park Subdivision for the construction of sanitary sewers. This construction should be accomplished during tile construction season of 1971. These sanitary sewers would service Lot 23, Block 1, of Nevilla Park Subdivision. If you have further questions regarding this matter, please contact this office. Yours truly, GREATER ANCHORAGE AREA BOROUGII Department of Public Works Robert Il. Morriss, Director Robert M. ltudnall, Jr. Administrative Assistant RM H/j t