Loading...
HomeMy WebLinkAboutMILE HI BLK 3 LT 7 Municipality of Anchorage Page [ of ~. ' DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744 On-Site Wastewater Disposal System and/or Well Inspection Report Permit Number: ,~l/~J C~ O 3/'~-~ PID Number: ~-O ~ ~[- [O Name: ~¢~ ~¢~~ Wastewater System: ~New B Upgrade Address:~ 77~ ~ ~ ABSORPTION FIELD Phone: ~ Nc. of Bedrooms:~ ~ Deep Trench ~Shal[ow Trench ~ Bed ~ Mound ~ Other Total Depth from original grade: LEGAL DESCRIPTION Soil R~ting: ~,~ GPD/Sq. Ft. Lot: ~ Block: ~ ~l'Subdiv~i°n:J~ ~t' Depth to pi~ bottom from original~ ~grade: Ft. Gravel depth beneath pipe~, Ft. Township: [Range: I Section: Fill added above original g~de: Gravel length:  Number of lines: Distance between lines: WELL: ~ New ~ Upgrade Gravelwidth: ~ Ft. / ~ Ft. Classification (Private. A,B,C): I Total Depth: / ~sed To: Tota~ absorption area: Pi~ material:~ ~ ~ Driller: ¢~~Drilied: Static Water Leve':Ft. 'nCer:~.~,~ ¢O~,¢. Date installed: ,/¢7 :Yield: ~Se, at- :Ft. [ Casing Heigh, Above Ground:Ft. TANK ~PARATION DISTANCES u Septic ~ Holding ~S.T.E.P. To= Septic Absorption Li~ Holding ~ubliCPrlvate Manufacture]: ~ Capacity in gall°ns: From Tank Field Station Tank S .... Lines ~ Material: ¢~ / Number of Compadments: s.~o~ , ' ' LIFT STATION wa~r 100~ lDO+ I00~ ~ Sizein gallons: Manufacturer: Lot ~ ~ Line /~ ~ /D~ }~ ~ ~ ~ ]~ ~ i ?'Pump on" level at: "Pump off" level at: High water alarm Foundation /D + I ~ I~ /O ~ ~ -- ~ ' ~ '/ ~ '1 Cudain ~ Pump~ake & Model Electrical InspectLoDs ped~m~ by: Remarks: ~ ~¢¢¢ ~¢&~ ~F~¢, ~ BENCU MARK J AsSumed J~O Elevation: ENGINEER'S SEAL a Inspections performed by: ~ND ~m~¢~ Dates: 1st/¢/z~/~&~~~~~'"~';~;""" ' -' ..... Department of Health and Human Se~ices ap ¢ &¢.%~. ~'%'~Z,'¢C;_,711~ ~%~¢ ~ ~ Reviewed and approved by: ~~/~ , Date: 72-0t3 (Rev. 9/91) MOA 25 AS-3UILT SYSYEM ]DETAILS/SITF LOT 7, 3LOCK 3, MILE HI S/]~ PLAN Permit SW960347 PID~050 201 10 LOT 6 % A-C=iG,0' B-C=32,0' A-D=20,9' B-D=38,6' A-E=91,0' B-E=57,0' A-F=96,0' B-F=77,O' "- TH ¢1 LOT LOT 7 w YELLO VACANT LITY SMT, ('0 SCALE: 1' = 50' 1 1/4' PVC FROM TANK TO FIELD FINISHED GRADE SEWER ROCK 56,25' SCALE, NTS PREPARE]} FOR: NERAK CONSTRUCTION, INC, P,O, BOX 770308 EAGLE RIVER, AK 99577 KN]] ENGINEERING 20441 PTARMIGAN 3LVD EAGLE RIVER, AK, 99577 (907)696-6111/Fox (907)696-8111 DATE, 7/28/97 I~RAWING # SCALE: AS NOTED 9GOG5-S1 ~Oo ~ OJ 0 CO ~0 ~1' O,J 0 ¢0 (.0 ~' Od 0 0 0 0'3 03 (33 0'3 0'3 {::0 O0 (:0 CO (~a~) 08/01/i997 14:B2 $958505 COLONIAL REAL ESTATE PAGE MR. MR, ELECTRIC OF ANCHORAGE ~2/~$ EAST DIiMONo ~LV'D. #109 (OFF PO~R) To whom it may concern: Dca: ladies and Gentlemen: Mr. Electric of Anchorage did a minimum mount of work on the lift station o~ lot 7 block 3 in the Mile Iqigh Subdivision. However I called Mr. John Atbright with Dalton _Electric and he a~sured me the depth requirements were f-h~h~ff[i~-t~rs are up to ~ff~'~. Electric did test the system and it was working at that time of the test, June 16t" 1997. There has no customer complaints about the system. According to Mr. Albrigbt, his portion of the system meets NEC code requirements and t wit~ concur with his judgment, to the best of my knowledge the system meets NEC code requirements. Also the inspection compliance was met. audible alarm inside the garage. Gregory G, Plummet 203 EAST DIMOND BLVD_ #'10~ ANCHORAGE ALASKA 99515 (907) 5Ol 8655 FAX: (907) 561-~0'~8" ' LIC #AA~2002 10:37 9075941211 S AND S ENGINEERING ELECTRIc ON ANCH PAGE 02 ~oo2 MR. MR. ELECTRIC OF ANCHORAGE 105 EAST DIMOND BLVD.//109 Anchorage, ALASKA 99515 LOCATION: 5630 - A #9 SILVERADO WAY (OFF POTTER) To whom it may concern · Dear ladies aud Gentlemen: Concerning The lift station at Mile High Lot, Note on invoice #3514 when the technician installed the audio signal inside the garage it was noted that thc wiring had been compromised. Currently, the wiring coming from the lift station is type LrF-B. However thc wire terminated in thc control box is 1),pc NM-B. This would indicate that thc wiring was spliced someplace in thc ground or thc conduit. ]~ither way, Type NM-B is un-expectable for th/s application, This was brought to thc contractor attention but there w~s no oct/on taken, to my knowl~g~, to make the proper repairs. At this time I can only say that the system was checked and working, I can not say it is to NEC code. Gregory G. Plummet 205 EAST DIMOND BLVD.//109 ANCHORAGE ALASKA 99515 (907) 561 8658 FAX: (907) 56D8058 LIC # AA22002 JUL--25--97~WED 05:0? PM SULLIVAN WATER WELLS 608..~75~444444444444 P. 01 by DOC Co. dba SULLIVAN WATER WELLS P-O. DOX 6?02?'2, CHUGIAK. ~"~67 · TELEPHONE 6,,.2759 ADDRESS LEGAL DESCRIPTION_ DATE · Started PERMIT NUMBER $ DEPI'H OF WELL '-~ ~ STATIC LEVE:L OF WATER Fr. /--~" ~' DRAW DOWN FT, KIND OF CASING ~_~ // ' From_. 4 rom I'/ ,om!!4 KIND OF FORMATION: '-~ · From . 0 Ft. to ~-~Ft.~.~D~. J'ir-le~4 d~° From Ft. to__FL From Ft. to Ft. ~FZ g~ From~rt_ to .et_ From FI. lo~. Ft _ ~ From Ft. to Ft From Ft, to Ft, ,5o From Ft. to~Ft From Fi, to Ft ~ ~rom FL to_~Ft, From Et. to Ft._ ,.,.~,,,., From fr- to From Ft. to.__Ft. _ From__ Ft. to~ F~om Ft. to~ FI, '"" Froth .Ft. to MISCL. INFORMATION: ,.,.. / ~._/t // - __ ,Fl. .Ft. Fr . . RECEIVED AUG 4 1997 Municipality of Anchorage Dept, Health & Human Services DRILLER'S NAME ~~ MUNICIPALITY OF kNCHORAGE DEPARTMENT OF HEALTH AND HUMAN SERVICES P.O. BOX 196650, 825 "L" STREET, ROOM 502 ANCHORAGE, ALASKA 99519-6650 ON-SITE WELL AND WASTEWATER DISPOSAL SYSTEM PERMIT PERMIT NUMBER:SW960347 DESIGN ENGINEER:KND ENGINEERING OWNER NAME:CARL VAN VECHOVEN OWNER ADDRESS:P.O. BOX 770308 EAGLE RIVER, AK. 99577 PARCEL ID:05020110 LEGAL DESCRIPTION: MILE HI BLK 3 LT 7 PERMIT REVISED 5/20/97 LOT SIZE: 37462 (SQ. FT.) NUMBER OF BEDROOMS: 3 THIS PERMIT: DATE ISSUED:10/ll/96 EXPIRATION DATE:10/ll/97 THIS PERMIT IS FOR THE CONSTRUCTION OF: DISPOSAL FIELD /SEPTIC TANK / WELL SYSTEM ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH: THE' ATTACH.ED APPROVED DESIGN. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS 15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80). THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY CALLING 343-4744 ( 24 HOURS ) (NOT REQUIRED FOR WELL ONLY PERMIT) FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING WEATHER MUST BE EITHER: A. OPENED AND CLOSED ON THE SAME DAY B. COVERED, SEALED AND HEATED TO PREVENT FREEZING THE FOLLOWING SPECIAL PROVISIONS. SPECIAL PROVISIONS: REVISED PERMIT BASED ON REVISED DESIGN DATED 5/12/97 1. ENSURE A 6 FT. MIN. VERTICAL SEPARATION TO BEDROCK. 2. TRENCHES MUST FOLLOW THE NATURAL CONTOUR AS REQUIRED AND DESCRIBED BY AMC 15.65.060.G5. 3. THE SETBACK DISTANCE OF 50FT. AS DESCRIBED IN AMC15.65.060.A1B IS WAIVED TO A MIN. DIST. OF 35FT. 4. ASBUILT MUST INCLUDE A PROFILE/CROSSLSECTION SHOWING THE TRENCH(ES) PLACEMENT BELOW ORIGINAL GRADE AND MUST INCLUDE THE FINAL GRADE OVER AND DOWNSLOPE OF SYSTEM SHOWING THAT AMC 15.65.060.A1B. HAS BEEN MET. FINAL APPROVAL FROM THIS DEPARTMENT WILL NOT BE GRANTED UNTIL FINAL GRADING IS COMPLETED AND ALL SLOPE SETBACK REQUIREMENTS ARE MET AND ARE ACCURATELY DOCUMENTED FOR BOTH THE ORIGINAL AND REPLACEMENT SITES. DATE: DATE: WASTEWATER DISPBSAL SYSTEH LOT 7, BLr]CK 3, MILE LOT 6 376.0' , DETAILS/SITE PLAN HI S/D CONTOUR INTERVAL = 1' LEIT 6 LOT 7 fACANT NILE - HI JE ~c~ 20' UTILITY :SMT, SCALE: l'--iUO 1 1/4' PVC SYSTEM DETAILS 1/4' PVC FRI3M TANK TO FIELD 3/16' HOLES @ 1.9' SPACING 56.25' ~ i M~'~,~-. SCALE: t":. ~0' I1/~' 250 STEP TANK PRESSURIZED DISTRIBUTIIgN SYSTEM HOLE SPACING DESIGN 1. THD= 45' 2. HOLE SIZE = 3/16' = 1.gO GAL. PER HOLE @ 30 PSI 3. 29 GPM (PUMP DELIVERY)/1.00 GALS./HDLE = 29 HOLES 4. 56.25 LF LATERAL/29 HOLES = 1.9' SPACING PER HOLE 5. ALL HALES SHALL HAVE CAPS INSTALLED PER MANUFACTURES SPECS. 6. HALES AT END OF LATERAL SHALL DE CONST. W/O CAPS AND PLACED DOWN. 7. CISNTRACTOR SHALL USE 1 1/4' PVC FRI]N TANK TI3 FIELD AND IN LATERALS. DESIGN DETAILS 3 BaRN X 150 dP]] = 450 GPa 450 GPa/0.8 GPa PER SQ. FT. = 568.5 SQ. FT 56B.5/5'(0.5' GRAVEL) x 0.5(~ide)= 56.~5' Trench Total depth oF sys±em is 6' From orlglna[ grade. Lot h~s bed subst~ntic[ regrading since ~es±hoLes. NOTES~ 1. USE 1250 STEP SEPTIC TANK, INSULATE TANK IF <4' COVER, B, INSULATE TRENCHES WITH R' ND DURIAL FOAM. 3. CONTRACTOR WILL ENSURE MAXIMUM ~X SLOPE INTO SEPTIC TANK, 4, ADDITIONAL FILL WILL DE ADDED OVER SYSTEM TB ACHIEVE MIN, 3' COVER, 5, DRAINAGE FIELD TO BE A MINIMUM OF 35' FROM SLOPES IN EXCESS DF 25%, PREPARED FOR: NERAK CONSTRUCTION, INC. P,O, BOX 770308 EAGLE RIVER, AK 99577 KND ENGINEERING 20441 PTARMIGAN BLVD EAGLE RIVER, AK, 99577 (907)696-6111/Fox (907)696-8111 DRAWING rev. 10/10/96 rev, 5/18/97 SCALE: 1' = 100' 96o65-si PERFORMED FOR: Municipality o! Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST 1 2 3 4 5 6 7 8 9 10 '1] 12 13 14 15 16 17 18 19- 20- COMMENTS WAS GROUND WATER ENCOUNTERED? IF YES, AT WHAT DEPTH? Depth to Water Alter -- /~ ~/~O~./d._. monitoring? Township, Range, Section: SLOPE SITE PLAN Date: J I Gross Net Depth to Net Reading Date Time Time Water Drop ./ .¢- ¢ -'~.? / ; 2 ~ - ia ~/~ ,, _ ~-. I; ~4, /o ~,;~ 7 ~W" / ~/~" ~ ~ 1~ ~ 7 - i~ ~ tz,, _ ~ /,'~7 /o ~,~~ ~/~,' / ~/~ ,' ~ / ~ ~ /P .,,'~ 7 ~/~" I '/~" 7 ~ / :~ - '~ 7~ ,, _ ~ ~9 /~ ~,'~ 7~/~'' / ~" 9~ ~ ', Io - ~'.1~" - lo Z ', ~ otO ~ ,. '~7 ~ /~ " / Zz " PERCOLATION RATE (m~nules/]nch) PERC HOLE DIAMETER TEST RUN BETWEEN ~ FT AND -,~ FT ACCORDANCE WITH ALL STATE AND MUNICI~/L GUIDELINES IN EFFECT ON THIS DATE. DATE DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST PERFORMED FOR: 1 2-- 3 -- 4 5 6. 7 8 9 10 '11 12 13 14- 15 16 17 18 19, 20- WAS GROUND WATER ENCOUNTERED? COMMENTS Township, Range, Section: "'"'~W ''~ q SLOPE SITE PLAN IF YES, AT WHAT DEPTH? Deplh to Water Alter J~oniloring? Dale:. Reading Date Gross Net Depth to Net Time Time Water Drop 2. /: ~ 3 /o ,~,'. //'/:¢" =; y~" 3 ~ I.~¢ ~ ~" - ~ / .'¢¢ /o.,,'~ /¢ ~/~" ~¢/~" ~ E /', ¢~ - ~ '/~ .. _ 7 ~ I;5~ ~ ~" - ~ ~'~ /~,~ /D ~/~" z ~/~" IO 2:17 I O ~ , q : i o ~/a'' ~ '~/~ " PERCOLATION RATE __ (mmuleszmchJ TEST RUN BETWEEN ,~ FT AND ACCORDANCE WITH ALL S'fATE AND MUNICI'P'AL GUIDELINES IN EFFECT ON THIS DATE DATE A/ oA MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND HUMAN SERVICES P.O. BOX 196650, 825 "L" STREET, ROOM 502 ANCHORAGE, ALASKA 99519-6650 PAGE 1 OF 2 ON-SITE WELL AND WASTEWATER DISPOSAL SYSTEM PERMIT PERMIT NUMBER:SW960347 DESIGN ENGINEER:KND ENGINEERING OWNER NAME:CARL VAN VECHOVEN OWNER ADDRESS:P.O. BOX 770308 EAGLE RIVER, AK. 99577 PARCEL ID:05020110 DATE ISSUED:10/ll/96 EXPIRATION DATE:10/ll/97 LEGAL DESCRIPTION: MILE HI BLK 3 LT LOT SIZE: 37462 (SQ. FT.) NUMBER OF BEDROOMS: 3 THIS PERMIT: 3 THIS PERMIT IS FOR THE CONSTRUCTION OF: DISPOSAL FIELD /SEPTIC TANK / WELL SYSTEM ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH: 1. THE ATTACHED APPROVED DESIGN. 2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS 15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (iSAACS0) . 3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY CALLING 343-4744 ( 24 HOURS ) (NOT REQUIRED FOR WELL ONLY PERMIT) 4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING WEATHER MUST BE EITHER: A. OPENED AND CLOSED ON THE SAME DAY B. COVERED, SEALED AND HEATED TO PREVENT FREEZING 5. THE FOLLOWING SPECIAL PROVISIONS. SPECIAL PROVISIONS: 1.) THE MAXIMUM TRENCH DEPTH MUST NOT EXCEED 8FT. BELOW ORIGINAL GRADE. 2.) TRENCHES MUST FOLLOW THE NATURAL CONTOUR AS REQUIRED AND DESCRIBED BY AMC 15.65.060.F3. 3.) ENSURE THE REQUIRED SET BACK DISTANCE BETWEEN MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND HUMAN SERVICES P.O. BOX 196650, 825 "L" STREET, ROOM 502 ANCHORAGE, ALASKA 99519-6650 RECEIVED BY: ISSUED BY: TRENCHES IS MET AS REQUIRED BY AMC15.65.060.A1D. THE SETBACK DISTANCE OF 50FT. AS DESCRIBED IN AMC15.65.060.A1B IS WAIVED TO A MIN. DIST. OF 35FT. ASBUILT MUST INCLUDE A PROFILE/CROSS-SECTION SHOWING THE TRENCH(ES) PLACEMENT BELOW ORIGINAL GRADE AND MUST INCLUDE THE FINAL GRADE OVER AND DOWNSLOPE OF SYSTEM SHOWING THAT AMC 15.65.060.A1B. HAS BEEN MET. FINAL APPROVAL FROM THIS DEPARTMENT WILL NOT BE GRANTED UNTIL FINAL GRADING IS COMPLETED AND ALL SLOPE SETBACK REQUIREMENTS ARE MET AND ARE ACCURATELY DOCUMENTED FOR BOTH THE ORIGINAL AND REPLACEMENT SITES. DATE: DATE: PAGE 2 OF 2 SEP-~4-96 TUE 01:84 PM KND.ENGINEERING %., Fax Note 7071 Dste 20441 PTARMIGAN BLVD. EAGLE RIVER, AK 99577-8736 (907)696-6111/FAX (907)696~8111 October 10, 1996 Municipality of Anchorage Dept. of Health & Human Services On-Site Services Section P. O. Box 196650 Anchorage, Alaska 99519-6650 Subject: Lot 7, Block 3, Mile Hi S/D RECEIVED OCT ! 0 996 Municipality ol A~ci'~orage Dept. Health & Human Services Dear Mr. Williams: On September 9th, we submitted an application for a well and septic permit for the referenced lot. That permit ended up being lost. On September 24th, ! faxed a copy to your office as a replacement and signed the faxed copies as that appeared to be a concern to you. Within that application was a request for a slope wavier of 20 feet for the primary field and "0" feet for the reserve field. On September 26th, I received notice that waivers to slope would not be granted for any less than 35 feet. On that same day I contacted your office and requested a meeting in the field to discuss the situation. On September 30th, both you and Mr. Cross met with me at the site and reached an agreement as follows: That I would modify the drawing to show the trenches being moved up slope so that they would be a minimum of 35' away from the steep cut bank. In turn you would issue the permit so that the owner could pursue his land use permit. At the owner's option, he could either provide a septic system that was in keeping with the 35 foot set back requirement from slopes in excess of 25% or dig another testhole on the other side of the lot, confirm acceptable soils with a percolation test and proceed with moving (flip flopping) the well and septic. On October 1st, I resubmitted the site plan with the requested change. On October 9th you contacted me and indicated that what was shown was not acceptable to you and that you now wanted me to provide changes to the site plan modification that would support the site plan shift that you required. I advised you that I can provide you a drawing that would illustrate a design that you requested, but that I couldn't assume any responsibility for its construction or design applicability to the lot. Regardless, you requested that I provide you this information anyway. Within 30 minutes you called my office back and stated that you were sending me a written list of discrepancies Subject: Lot 7, Block 3, Mile Hi S/D October 10, 1996 Page 2 of 3 that addressed your new concerns with the site plan submitted. Based on the above and your October 9th fax, I am providing you the following requested information. The responses correlate to the numbered items on your fax. Al. A2. A3. A4. A5. The slopes in the area that we were requested to shift the trench to are approximately 60%. This differs significantly with the original area slope of 31% which required a waiver of 20 feet and could have been easily regraded to meet the 25% slope requirement. As it is within the department's purview to grant waivers, since you have visited the site at least three separate times, and we met and discussed the modifications on the site, I can only assume that you were anticipating granting the necessary slope waivers to construct the system. I have provided a conceptual profile that would illustrate one approach to developing a system at this site. We have provided a drainage arrow with estimated slopes that should augment the existing surveyed topography. No action required to respond to. I have reviewed the requirements under code for site plans and have been unable to locate any referenced to a requirement to show any change in slope by grading or cutting or a profile section of the site as it will be at the time the trench is excavated. If these are requirements then please provide the specific section within code that it refers to. With regards to the request to show how the effluent is equally divided between the two trenches please refer to the submitted site plan and you will notice that there is a splitter clearly shown. I have reviewed the requirements under code for site plans and have been unable to locate any reference to a requirement to specifically address the burial depth of the septic tank. Please provide the specific section within code that it refers to. At this time we do not anticipate any excessive burial depths. If burial depths are required we will insure that the tank is appropriately specified for the depth of bury. So far the soils logs have been submitted three times to your department. On the last submittal logs from another project got mixed up with the logs for this site. Attached you will find the correct logs. All known systems within 200 feet of the our proposed wastewater system have been shown in accordance with code. A note to that effect is on all the submittals. I have duplicated that note and placed it on lot 6 Subject: Lot 7, Block 3, Mile Hi S/D October 10, 1996 Page 3 of 3 for your convenience. A6. I have corrected the typographic error on the lot designation. Without question this is a difficult lot to construct. However, it has been over a month since we submitted a request for permit. At this time the ground is freezing and the snow is falling. Costs for construction are increasing as well as the difficulty in construction. It is essential that the permit be issued so that any additional costs can be mitigated. Please contact me immediately if you have any more questions regarding this application. I can be reached at 696-6111/FAX 696-8111. Respectfully submitted, Ik~Ix~I~ Engineering Kenneth M. Duffus~ P.E. attachments: Modified Wastewater Absorption System Details/Site Plan Soils Log/Percolation Test Profile View of Theoretical Installation WASTEWATER 9ISPBSAL SYSTEM DETAILS/SITE PLAN LOT 7, BLOCK 3, MILE HI S/D ND PUBLIC WELLS WITHIN 200' OF PRDPBSEB SYSTEM EXCEPT AS NOTED NO PRIVATE WELLS WITHIN 200' DF PROPOSED SYSTEM EXCEPT AS NOTED, SYSTEM DETAILS LOT 6 CONTOUR INTERVAL = 1' LOT 6 ID, 1 /ACANT iSNT. MILE - HI AN VACANT UE SCALE: 1"=100' CB M T{~~~ CD //-SPLITTER x~ SCALE: 1"= 80' DESIGN DETAILS 3 BDRM X 150 GPD- 450 GPD 450 GPD/0,6 GPD PER SQ, FT. = 750 SQ. FT 750/a' X 7 (7.0' GRAVEL) - 53.57 FT, TRENCH To~a[ depth oF system is 8' From orlglna[ grade, Lot has had sul0stan~iel regradln9 since ~es~cho[es, NBTES~ l, USE SPLITTER BETWEEN THE TWO FIELDS, 2. USE 1000 GALLON SEPTIC TANK, INSULATE TANK IF <4' COVER, 3, INSULATE TRENCHES WITH 2' HD BURIAL FOAM. 4, CONTRACTOR WILL ENSURE MAXIMUM 2Y. SLOPE INTO SEPTIC TANK, 5. ADDITIONAL FILL WILL BE ADDED OVER SYSTEM TO ACHIEVE MIN, 3' COVER, 6, DRAINAGE FIELD TU BE A MINIMUM BF 35' FROM SLOPES IN EXCESS OF 25×. PREPARED FiR: NERAK CONSTRUCTION, INC. P.D, BDX 770308 EAGLE RIVER, AK 99577 KND ENGINEERING 20441 PTARHIGAN BLVD EAGLE RIVER, AK, 99577 (907)696 6111/Fox (907)696-8111 DATE~ rev. 10/10/96 SCALE: l' = 100' I 96065-S1 ? LE6AL D~$CRIPT ON' ~'~'/~ 9', 'r-~/,')~:3 /L~/~.~. /~'/Township, Range, ~ect,on: __-- ' SLOPE -. Municipality ol Anchorage DEPARTMENT OF HEALTH & HLJMAN SERVICES SITE PLAN t 2 ;3 4 5 6 / 9 10 11 12 13 14 15 16 18 19 20 WAS GROUND WATER Reading ~/ Net Time Depth to Net / /~ ' "~ ;' ' WAS pERFORMED IN ACOORD~CE WiTH ALL STA~E AND MUNICIPAL GUIDELiNE~ IN EFFECT ON THIS DATE DATE: 72.~ IRev. 4/85) Municipalily of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST (FEET) 1 2 3 4 7 8 ~0 12 13 14 1¢- 17 18 2O COMMENTS _ Township, ~ange, Section: SLOPE SITE PLAN WAS GROUND WATER ENCOUNTERED? S L IF YES, AT WHAT 0 DEPTH? p E Depth 10 Water Aller Monitoring? Date: Gross Net Oeprh to Net Reading Date Time Time Water Drop PERCOLATION RATE -~,' Y tm,nules/JnCh~ PERC NOLE DIAMETER ~EST RUN BETWEEN °~ FT AND . ? FI , d ACCORDANCE wi f ti ALL S'~ A I E AND MUNICIPAL GUIDELINES IN EFFECT ON Tills DAlE CERIIFY IIIAi ,/f, HIS TESl WAS PERFORMED IN Municipalily of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 'L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST DEPTH 2 3 4 7 10- 12 13- 14 15 17 18 19 20 WAS GROUND WATER ENCOUNTERED? PERFORME[ Township, Range, Section: ~ ~/ SLOPE SITE PLAN S L IF YES, AT WHAT O DEPTH? p E Depth to Waler After Monitoring? Dale: Gross Net Depth to Net Reading Date Time Time Water Drop PERCOLATION RATE /0 {mmulesnnchJ PERC HOLE DIAMETER TEST RUN BETWEEN __ FT AND '~' ~ FT ACCORDANCE wi1 H ALL S1A I ELAN[) MUNICIPAL GUIDELINES IN EFFE(;I ON THIS [)ATE DATE -- . -- ....... · o $EP-24-96 PERFORMED FOR: -- -- LEGAL, DESCRIP'I'ION:~~-;~ ' (FEET) 3 10 14 17 20 TUE 01 '06 PM KNI).ENGINEERING 907 - , t~/'~ ~ ' Township, Range, Section: SLOPE SITE PLAN COMMENTS WA5 GHOUNO WATER IF YES, AT WHAT Mofli~ring~ ~/~ (~ Gro~s Net ~pth to Net Reading Dale Time Time Water ~_ J ,,~ .~. ~/~ -'~"' TEST RUN BETWEEN ~ g' FT AND () 0 -FT PERFORMED DY, '"'~ .('"' '" .... ~' '~'-~ ' _ /, v'/?' / ;,~, A&C, ORr)ANC,,F WITH ALL STATE AND MUHI~;IPAL GUIDELINES iN EFFECT ON THiS DATE DATE WASTEWATER DISPOSAL SYSTEM DETAILS/SITE PLAN LOT 7, ]~LOCK 3, MILE HI S/l] LOT 6 CONTOUR INTERVAL = 1' NILE - HI LOT 6 )D, 1 LOT 7 20' UTILITY SMT. UE /ACANT SCALEi 1"=100' 1 1/4' PVC /16' HOLES @ 6,8' SPACING o _D MT SYSTEM DETAILS 1/4" PVC FROM TANK TO FID 1/2" PVC FOR MANIFOLD J 1 1/2' PVC-- 1 1/4- Pv0-- 250 SCALE~ 1"= 20' PRESSURIZED STEP TANK ]DISTRIBUTION SYSTEM HOLE SPACING DESIGN 1. RESIDUAL HEAD = 5' 2. HOLE SIZE = 3/16' = i.O0 GAL. PER HOLE @ 30 PSI 3. 30 GALS (PUMP DELIVERY)/1.00 OALS./HDLE = 30 HOLES 4, 205 LF LATERAL/30 HOLES = 6,8' SPACING PER HOLE 5, ALL HOLES SHALL HAVE CAPS INSTALLED PER MANUFACTURES SPECS. 6, HOLES AT END BF LATERAL SHALL DE CBNST. V//O CAPS AND PLACE~ DOWN, 7, CONTRACTOR SHALL USE 1 1/4' PVC FROM TANK TB FIELD AND IN LATERALS, 8, CONTRACTOR SHALL USE 1 1/~' PVC FOR MANIFOLD. DESIGN DETAILS 3 BORN X tSO GPI] = 450 GPO 450 GPO/O.4 GP]] PER SO, FT, = L1~5 SO, FT 1,125/20' (0.5' GRAVEL) = 56,25 FT. DEl) Totrlt depth DP system is 4' Cron or'iDin(iL gr~lde, Lo1; h(is had substantlo( r'egr'(idln9 since {esthotes. NOTES~ I, USE 1250 STEP SEPTIC TANK, INSULATE TANK IF <4' COVER, 2, INSULATE TRENCHES ~¢ITH 2' HD BURIAL FBAN. 3, CONTRACTOR WILL ENSURE MAXIMUM SM. SLOPE INTO SEPTIC TANK. 4, ADDITIONAL FILL WILL BE ADDED OVER SYSIEN TO ACHIEVE MIN, 3' COVER, 5, DRAINAGE FIELD TO BE A MINIMUM OF 35' FRDN SLOPES IN EXCESS OF 25×, PREPARED FOR: NERAK CONSTRUCTION, INC. P,B. BOX 770308 EAGLE RIVER, AK 99577 KND ENGINEERING 2044~ PTARMIGAN BLVD EAGLE RIVER, AK, 99577 (907)696-6111/Fcx (907)696-81tl rev, 10110/96 rev, 4/30/97[DRAWING # SCALE~ 1' = 100' I 96065-S1 CJ3NTBUR ]}ETAI'LS/S]iTE PLAN LOT 7, ]}LOCK 3, MILE HI S/D BF SL'~PE ITY E SMT, P1]~ t- H YENUE PREPARED FBR~ NERAK CDNSTRUCTInN, INC. P.O. BOX 770308 EAGLE RIVER, AK 99577 KND ENGINEERING 80441 PTARMIGAN EAGLE RIVER, AK, 99577 (907)696 Gill/Fax (907)696 8111 MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & HUMAN SERVICES Dit'ision of Environmental Services On-Site Services Section P.O. Box 196650 Anchorage, Alaska 99519-6650 343-4744 Parcel I.D.# (2~--0 -~! -!O 1. GENERAL INFORMATION Complete legal description CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING Lot 7: Block 3: Mile Bi Subdivision Location (site address or directions) ,F:',:¢i:~)perty owner:" "Nerak Con~=truction NHN Mile Hi Ave. Day phone ..... ;M.aili.ng a.ddre.s.s..~.i P.O. Box 871647 ..... ,Lending agency ..... Mafl~ g address' "Agent ' Address Wasilla, AK 99687 Day phone Day phone 2. NUMBER OF BEDROOMS: 3. TYPE OF WATER SUPPLY: Unless otherwise requested, HAA will be held for pickup. .3 Individual well xx× Community well Public water NOTE: TYPE OF WASTEWATER DISPOSAL: NOTE: If community well system, provide written confirmation from State ADEC attest- ing to the legality and status of system. Individual on-site x×× Holding tank Community on-site Public sewer If community wastewater system, provide written confirmation from State ADEC attesting to the legality and status of system. 72-025 (Rev, 1/91) Front MOA~21 STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health Authority Approval'application shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on the date of this inspection. S & S ENGINEERING Name of Firm 17034 Eagle River Loop Road No. 204 Address Eagle River, Alask, a?9577-- ~. Engineer's signature Phone Date DHHS SIGNATURE v/ Approved for Disapproved. Conditional approval for bedrooms. bedrooms, with the following stipulations: Additional Comments By: The Municipality of Anchorage Department of Health and Human Services (DHHS) issues Health Authority Approval Certificates based only upon the representations given in paragraph 5 above by an independent professional engineer registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHHS do not conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 72-025 (Rev. 1/91 ) Back MOA f¢21 MUNICIPALITY OF ANCHORAGE ENVIRONMENTAL SERVICES DIVISION Municipality of Anchorage AU6 0 z~ ]~ DEPARTMENT OF HEALTH & HUMAN SERVICES ' Environmental Services Division' ~J~l 825 L Street, Room 502 · Anchorage, Alaska 99501 · (907) 343 Legal Description: A. WELL DATA Well type Log present .~) Total depth Sanitary sea~)'N ) Health Authority Approval Checklist Parcel If A, B, or C, attach ADEC letter. ADEC water system number Date completed '7 ~ ~ "7 Cased to .~() I ~- ' i 1~/2_Casing height (above ground) Wires properly protecte(:~N) Date of test Static water level Well production WATER SAMPLE RESULTS: Coliform O Date of sample: ~ -' ~$ B. SEPTIC/HOLDING TANK DATA FROM WELL LOG Nitrate AT INSPECTION ~) o / (,, ?---- Other bacteria ¢ Collected by: ~ / '~' ~'~ '~--)4 /~, Date insta ed ~ ~ ~ 7 Tank size /25-o Number of C0ml~artments ". ~-- Cleanouts~N)___.~ Foundation.~e~'~t'~{~N)-.,, ',7/ Depression (Y~ ~ High water alarm (Y/~ ~ Date ~d~p.i.~g .... ~/~". ~./~, ~ ~ Lengt~t.,' ~¢. ~'~ Width'.(? ~ / Gravel thickness below pipe ~ ~ Total depth ~, ~ Effective a~orpt!on ar. ea ,~ ~ . ~ Monitoring Tube present ~)~ Pepressibn over field ~ ,~ Date of adequacbtest ~ - "~esult, ,Pass/Fail,-- hor bedrooms Fluid depth in absorption field before test (in.); -" Fluid depth--'---- (ins) Minutes later: Peroxide treatment (past 12 months) (Y/N) · - -Immediately after ~er added (ira): Absorption rate = g:p.d. If-yes, give date " 72-026 (Rev. 3/96)* D. LIFT STATION Date installed Manhole/Acces~) High water alarm level at* Cycles tested ~ E. SEPARATION DISTANCES Size in gallons "Pump on" level at* *Datum "Pump off" level at* Septic/holding tank on lot Absorption field on lot Public sewer main Sewer/septic service line SEPARATION DISTANCES FROM WELL ON LOT TO: /O43 On adjacent lots / On adjacent lots /,~ 0 ,/ Public sewer manhole/cleanout / .-/' Lift station / SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOTTO: Foundation - Property line / o Absorption field Water main/service line /~ O /~ Surface water/drainage / o o Wells on adjacent lots SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOTTO: Propertyline /~ .( '~ Building foundation /o ~ ~ Water main/service line Surface water - 1 ~ ~ /¢ Driveway, parking/vehicle storage area Curtain drain /~-)~ -)-~z.~ /~r.~' ~ ~ Wells on adjacent lots /~D ENGINEER'S CERTIFICATION D~ ~ ~.~., ~ , .: I cedi~ that I have determined thru field inspections and reviewof Municipal rec~ ,t~the ab ~s are inconformanco~~Tu~"z~ct°nthisdate' t~ ' ~ -.. ~ ,~ ~...~, HAA Fee $ Date of Payment Receipt Number 72-026 (Rev. 3/96)* Waiver Fee $ Date of Payment Receipt Number MUNICIPALITY OF ANCHORAGE MEMORANDUM WATER WELL ADVISORY HEALTH AUTHORITY APPROVAL NO. ~QO~ During a recent Health Authority Approval on-site inspection and test of the potable water supply well on Lot 7 Block ~ of ~[~ ~[ Subdivision, the well's productivity was determined to be ~,S67 gallons per minute. The minimum well productivity required by this Department (AMC 15.55) for a ~ bedroom residence is o.~i gallons per minute° Although the subject well currently exceeds this minimum requirement, all parties concerned are advised that the production capacity of the well may fluctuate. Restriction of non-critical water uses such as washing cars and watering lawns and gardens may be required. This advisory must be attached to all copies of the subject Health Authority Approval. Northwest Efextric ~ Corrt~, Inc. 1220 East 76tfi. Ave. Suite #1221 Anchorage, Alaska 99518 Td: (SOD 3~-7711 F~: (907) 522-3508 RECEIVED AUG 1 1 1997 Municipalizy of Anchorage Dept, Health & Human Services August 8, 1997 Anthony Kim Municipality Of Anchorage DHHS Re: Lift Station Wiring, Mile High Rd. Eagle River, Alaska Anthony, A short history is in order regarding this residence. The lift station in concern here was originally installed and wired by another contractor earlier this year. During the process of the installation of underground AC power to the residence utility meter, the type UF cable supplying power and control to the lift station was damaged. The contractor, Newberry Alaska hired Dalton Electric to perform the necessary repairs, an employee of Dalton Electric was dispatched to perform these repairs. A period of time later, an inspection of the residence was performed for the reason of closing on a deed of trust (I assume this was the reason). The inspection was performed by Mr. Electric and his report noted that the repair work was substandard: type NMB romex used for the repair in place of type UF. Upon questioning the mechanic dispatched to perform the repair it was stated that this was not the case and he had in fact used type UF cable in conjunction with UL listed underground splice kits. For further verification, I travelled to the residence and performed a visual inspection of the cable type that was installed. The cable type installed by our mechanic was indeed type UF and is clearly labeled on the jacketing of the cable. Also, from all appearances and from the conversationwith my mechanic, the burial depths of the cable are also NEC code compliant. My electrical administrator license is 603. Jon Albright Dalton NW Electric, Inc. HEALTH AUTHORI~P( APPROVALS SEWER&WATER MAIN EXTENSIONS SEWER & WATER INSPECTION ENGINEERING STUDIES AND REPORTS WELL INSPECTION & FLOW TEST SITE PLANS ROAD DESIGN SOILTEST PERCOLATION TEST STRUCTURAL & MECHANICAL INSPECTIONS ON SITE WASTEWATER DISPOSAL SYSTEM DESIGN ROBERT C. COWAN, RE. ROBERTA. SHAFER, P.E. CIVIL ENGINEERS (907) 694-2979 rWELL RECOVERY TEST DATA FAx(90z)e94-12~1 CLIENT: WELL LOCATION (legal): ~,---~oT' ~ ~-¢~\~ ~L.(~ t~t~ ~'~t, TEST DATE: '-( -Ii ~ ~-)'-~ TESTED BY: ~/~/~o ,.5 r> WELL DEPTH: ?~ ~ t WELL DRILLER: CASING DEPTH: ~'.~ I ~ ~ ~.?_~, DATE DRILLED: TEST PROCEDURE: MISC DATA: 1) Draw water down to pump. Casing Height: 2) Shut pump off 15-60 min. Sanitary Seal? -record time Wires in Conduit? -record meter reading Grading O.K.? 3) Turn pump on. Drawdown. Pump Depth: 4) Shut pump off. Samples Taken? -record time Date: -record meter reading 5) Calculate gaL/min, recovery. TEST DATA: START TIME: i O',t~ o/~¢¢,~ STATIC WATER LEVEL: TRIAL II PU P II T ME II METER II GAL./MIN. OFF //. I ON OFF OFF 2 ON OFF OFF 3 ON ~-' OFF OFF OFF OFF RESULTS: WELL CURRENTLY PRODUCES: FLOW RATE NOT GUARANTEED--SUBSEQUENT VARIATIONS CAN OCCUR. 17034 NORTH EAGLE RIVER LOOP ° SUITE 204 · EAGLE RIVER, ALASKA 99577 CT&E Environmental Services Inc. CT&E Ref.# Client Name Project Name/# Client Sample ID Matrix Ordered By PWSID Sample Remarks: 974014001 S & S Engineering L7, B3 Mile Hi S/D L7, B3 Mile Hi S/D Dri~ddng Water Client PO# Printed Date/Time 07/28/97 10:00 Collected Date/Time 07/23/97 10:30 Received Date/Time 07/23/97 13:05 Technical Director: Stephen C. Ede Released B~~ ~ Parameter Nitrate-N Total Coliform Results 0.I62 9 OB W/O COLI PQL 0.100 Units mg/L Allowable Prep Analysis Method Limits Date Date Init SM18 4500-NO3F 10 max SM18 9222B 07/24/97 JRJ 07/23/97 TNW Held For Confirmation CT&E Environmental Services Inc. Laboratory Division Drinking Water Analysis Report for Total Coliform Bacteria 2oo w. Potter Drive Anchorage, AK 99518-1605 READ hVSTRUCTIONS ON REVERSE SIDE BEFORE COLLECTI:VG SAMPLE MUST BE COMPLETED BY WATER SUPPLIER ID PUBLIC WATER SYSTEM l.l~. # J JJllJl ~ PRIVATE WATER SYSTEM Send Invoice J [3 Send Results ID Send Invoice Month Da)' Year SAMPLE TYPE: ~Routine ID Treated Water D Repeat Sample (for routine sample D Untreated Water with lab reft no. ) D Special Purpose SAMPLE LOCATION Comments: Tel: (907) 562-2343 Fax: (907) 561-5301 TO BE COMPLETED BY LABORATORY siS shows this. Water SAMPLE to be: atisfactory Unsatisfactory, Sample over 30 hours old, results may be unreliable Sample too long in transit; sample should not be over 48 hours old at examination to indicate reliable results. Please send new sample' via special deliver), mail· Date Received '~J~ Time Received Analysis Began Analytical Method: .l~Membrane Filter n MMO-MUG * Number ofcolonies/100 mi. Lab ReL No. Result* Analyst Sent to A.D.E.C. Anch Fblcs Jun Date: Time: Client notified of unsatisfactory results: Time Colle{~ted Collected By Phoned / BACTERIOLOGICAL WATER ANALYSIS RECORD MMO-MUG Result: Total Coliform E. Coil Membrane Filter: Direct Count 90~J~ U-)/C~ eD t i Fecal Coliform Confirmatio~ ~ ~ Final Membrane Filter Results Coliform/100 mi Colonles/100 mi COLIFIRM ~ Spoke with Time: [] Faxed Faxed Member of the SGS Group (Societe G/~nerele de Surveillance)