Loading...
HomeMy WebLinkAboutMILE HI #1 BLK 7 LT 10Mile HID #1 Block 7 Lot 10 #050-201-28 MUNICIPALITY OF ANCHORAGE Development Services Department Phone: 907-343-7904 On-Site Water & Wastewater Section Fax: 907-343-7997 Pump Installation Log Well Drilling Permit Number: _______________ Date of Issue: ____-____-____ Parcel Identification Number: ____-____-____ Legal Description Block Lot Property Owner Name & Address: Pump Installation Date: _____-_____-_____ Pump Intake Depth Below Top of Well Casing: __________ feet Pump Manufacturer’s Name: ___________________________ Pump Model: _____________________________________ Pump Size: ____________hp Pitless Adapter Burial Depth: _________ feet Pitless Adapter Manufacturer’s Name: _________________________ Pitless Adapter Installer: ____________________________ Well Disinfected Upon Completion?;;<HV No Method of Disinfection: _____________________________ Comments: Pump Installer Name: __________________________________ Company: ___________________________________________ Mailing Address: ______________________________________ City: ___________________ State: __________Zip: _________ Attention: The pump installer shall provide a pump installation log to On-site within 30 days of pump installation. 050 201 28 MILE HI #1 710 DUROCHER WESTON PAUL 12110 BUSINESS BLVD PMB 161 SUITE 6 EAGLE RIVER, AK 99577 07 17 2024 220 PD WATER SYSTEMS 4PWP07G 07C163P .75 12 MARTINSON PELLETS ANCHORAGE WELL & PUMP SERVICE 7640 KING STREET ANCHORAGE AK 99518 On -Site Wastewater Disposal System Permit MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Permit Number: OSP131307 Tax Code Number: 05020128000 Work Type: Septic Permit Effective Dates: September 11, 2013 to September 11, 2014 Design Engineer: ARC TERRA CONSULTING INC Subdivision: MILE HI #1 Site Legal Address: MILE HI #1 BILK 7 LT 10 G:0058 Owner/Address: DAVIS RICHARD L & TERRY L 35467 KALIFORNSKY BEACH RD KENAI AK 996115811 Site Mailing Address: 22230 UPPER CANYON DR, Eagle River This permit is for the construction of: Y Disposal Field Y Septic Tank N Holding Tank N Privy All construction must be in accordance with: Lot Size in Sq Ft: 56849 Total Bedrooms: 2 N Private Well N Water Storage 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Received By: Issued By: Date: Date: Municipality of Anchorage P.O. Box 196650 • 4700 Elmore Road Anchorage, Alaska 99519-6650 • (907) 343-7904 0 Fax (907) 343-7997 hftp://www.muni.org/Onsite Development Services Division On -Site Water and Wastewater Program trent S, 1� e ri EMv e artment **** VARIANCE/WAIVER REVIEW **** Waiver#: OSP131308 COSA#: Permit#:OSPI31307 PID#:050-201-28 Legal Description: Mile Hi #1. Block 7. Lot 10 Engineer: ArcTerra Applicant: Rchard & Terry Davis Your request for a waiver of the required 50 feet horizontal separation from the absorption field to a 25% or greater slope has been approved. The approved separation distance is 35.0 feet. This waiver approval applies to the proposed absorption field only. Any future upgrade to the on-site wastewater disposal system will require all separation distances be met or another approval from this department. ❑ The affected adjacent property owner(s) have been given a 7 day notice regarding this waiver. ❑ Notarized letter(s) of non -objection have been received from the owner(s) of the affected adjacent property. ® Adjacent properties are not affected by this waiver. ........................................................................ a . . . . . . Waiver is Granted: x Waiver is not Granted: Date: l t Approved by: Zye ame of Reviewer ...................................................... a.......................� Rec#: 025907 Amount: $200.00 Date Paid: 9/4/2013 **** VARIANCEIWAIVER REVIEW **** C " P **** VARIANCE/WAIVER REVIEW **** Waiver#: OSP131308 COSA#: Permit#:OSPI31307 PID#:050-201-28 Legal Description: Mile Hi #1. Block 7. Lot 10 Engineer: ArcTerra Applicant: Rchard & Terry Davis Your request for a waiver of the required 50 feet horizontal separation from the absorption field to a 25% or greater slope has been approved. The approved separation distance is 35.0 feet. This waiver approval applies to the proposed absorption field only. Any future upgrade to the on-site wastewater disposal system will require all separation distances be met or another approval from this department. ❑ The affected adjacent property owner(s) have been given a 7 day notice regarding this waiver. ❑ Notarized letter(s) of non -objection have been received from the owner(s) of the affected adjacent property. ® Adjacent properties are not affected by this waiver. ........................................................................ a . . . . . . Waiver is Granted: x Waiver is not Granted: Date: l t Approved by: Zye ame of Reviewer ...................................................... a.......................� Rec#: 025907 Amount: $200.00 Date Paid: 9/4/2013 **** VARIANCEIWAIVER REVIEW **** MUNICIPALITY OF ANCHORAGE n:t_ Community Development Department Phone: 907-343-7904 Development Services Division Fax: 907-343-7997 On -Site Water & Wastewater Program ON-SITE SEWER/WELL PERMIT APPLICATION Parcel I.D. 050-201-28 Property owner(s) RICHARD & TERRY DAVIS Day phone Mailing address 35467 KALIFORNSKY BEACH RD., KENAI, AK 99611 Site address 22230 UPPER CANYON DR., EAGLE RIVER, AK 99577 Legal description (Sub'd., Block & Lot) MILE HI #1 B7, L10 Legal description (Township, Range & Section) Lot Size 56849 Sa. Ft. Number of Bedrooms APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (® all that apply) Family [] Absorption Field [� Initial F-1Single (SF) Septic Tank [ Upgrade � (w/wo ADU) Duplex (D) F1Holding Tank ❑ Renewal ❑ Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: SLOPE SETBACK 35' Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. property owner or authorized agent) Permit/Rush Fees: 530.— Date of Payment: Receipt Number: 02!mo"i Permit No. me 13 i3o1 Permit App_9-1-12.doc Waiver Fees: MID, Date of Payment: )q 13 Receipt Number: D227-501 7 Waiver No. Mc 1q) J 1'6o? o Q+RCTERR9 , 4P September 3, 2013 AiicTERRA CONSUI,TING, INC 212 E. 51" Ave, Anchorage, AK. 99503 Office (907) 868-3791, Fax (907) 868-3793 Municipality of Anchorage Development Services Department On -Site Water & Wastewater Program P.O. Box 196650 Anchorage, AK 99519-6650 Subject: Upgrade Sewer Permit/ Slope Waiver— Mile Hi #1 Block 7, Lot 10 The absorption field of the subject property cannot be located. Subsequently, the owner has requested we proceed forward to obtain a septic permit to upgrade the septic system. The general slope of this lot is from north to south at a grade of approximately 5- 10% over the septic area with slopes greater than 25%v 35'+ from proposed field. On August 23, 2013 a testhole was performed to investigate soils and groundwater. The results of this test are attached for your review. The proposed upgrade will serve the existing 2 -bedroom house. We propose to install one deep trench. Groundwater was not encountered at excavation or at monitoring. The property and adjacent lots are served by private wells. There is no surface water within 100' of the proposed system and there are no known curtain drains within 50'. We do not expect there to be any adverse effect on adjacent lots by the development of this system. If you have any questions, please contact me at 868- 3792 / FAX 868-3793. Respectfully submitted, ArcTerra Consulting, Inc. ter: Kenneth M. Duffus,. Attachments: On -Site Sewer Application Wastewater Absorption System Details/ Site Plan Soils Log/ Percolation Test 20441 PTARMIGAN BLVD • EAGLE RIVER, AK 99577-8736 • PH (907) 868-3791 • FAX (907) 868-3793 WELL & WASTEWATER DISP❑SAL SYSTEM DETAILS/SITE PLA MILE HI #1 B7, L10 Cabo 2 VACANT BOUNDARY: 3� �o J4219s�'F STAKING: — CHECKED: R, �0 ASBUILT: RJ DATE: 9/4/ 1 533 5 S6I S " NW58 ACRD FILE: 13194 JOB N., 4 0 Pei exq¢�� Igc'•!9 6650 VACANT ,W ._ Re3p'06, 12352 0. 0 0 :' o •. 151,35 0040• Le 1 �3 9 S75.5 o 39.81 72352 ^`21 b0• S n` TO.56 q0• JPO VACANT _ "ER �A 'q L=119.12 4]. 0 ^= 6y a ORTVC Na6' 00' 0 'E d�59.�6as an d- u". R a AzAD Cz�eo �o 409 cA +b Gp N No GRAPHIC SCALE 4 0 50 100 "=100' d VACANT SCALE: 1 VACANT 9 o� 5 § cal,el V=- 100' PAGE 1 OF 3 NO PUBLIC WELLS WITHIN 200' OF PROPOSED SYSTEM. NO PRIVATE WELLS WITHIN 200' OF PROPOSED SYSTEM EXCEPT AS NOTED. NO SEPTIC SYSTEMS WITHIN 200' OF PROPOSED WELL EXCEPT AS NOTED. ��_` AW �� of AL4 , �co r 1 / * TH * �I / KENNETH ` E -7 1 M.1 U JOV � . C 47 1 \ $� FESSIot3A= DESIGN DETAILS 2 BDRM X 150 GPD = 300 GPD 300 GPD/1.2 GPD PER SQ. FT, (2,4 MIN/IN.)= 250 SQ. FT (250 / 2X6' ED (6' GRAVEL) = 21 FT. TRENCH USE 1 TRENCH - 21 (L) X 2' (W) X 6'(D) Total depth of system Is 9' from original grade. Total depth of gravel below distribution pipe is 6' NOTES: 1. CONTRACTOR & ENGINEER TO VERIFY INTEGRITY OF SEPTIC TANK AND REPLACE AS REQUIRED. INSULATE TANK IF <4' COVER, 2. INSULATE TRENCHES WITH 2' HD BURIAL FOAM. 3. CONTRACTOR WILL ENSURE MINIMUM 2% SLOPE INTO SEPTIC TANK. 4. ADDITIONAL FILL WILL BE ADDED OVER SYSTEM TD ACHIEVE MIN, 3' COVER IF REQUIRED. 5. CONTRACTOR WILL ENSURE ALL SEPARATIONS TO ADJACENT WELLS & SEPTICS, PREPARED FOR1 rip RICHARD & TERRY DAMS 22230 UPPER CANYON RD. EAGLE RIVER, AK 99577 FIELD BOOKS COMPUTED: BOUNDARY: DRAM: BMW STAKING: — CHECKED: KMD ASBUILT: RJ DATE: 9/4/ 1 DNG. flit=: GRID: NW58 ACRD FILE: 13194 JOB N., 13194 (I�li,'7■■1111 Rryf'VSULTING, 00 U WASTEWATER DISPOSAL SYSTEM DETAILS MILE HI #1 137, L10 � 1393 S%3o OQ PPER .. cT I TA PERMANENT L-1 3 `..HAR .ICADE PREVENT � M PA KING./. IVING d i SP1"..... 0 3c?p co . L� RAGE X ..0 I] MISSION. . EXIS 'fNGS.T. �...__t X... .....PER CGDE .&.. APPR .. ............. LL. NEW....... ULD C B .......... . ... 1000 . S.T. ... . INSULATED 0 / W F UNDER DRIVE, o 3c�♦ o x p�\ o a o /Fl h EXISTING S.T, \ FLAG ALL WELL RADII & EASEMENTS PRIOR TO CONSTRUCTION Scalel 1'= 30' �trr� PAGE 2 OF 3 A44 \, PREPARED FOR: RICHARD & TERRY DAMS CT$ / �. 22230 UPPER CANYON RD. Sfl� RRPuff* Tx * EAGLE RIVER, AK 99577KENNETH M. DFIELD BOOKS covauiED:BOUNDMV: DRAMN: BMW����� VMING: CNECNED: KMD/ VAmul�T.. RJ DACE: 9/4/13Dxc. e: GRID: NW58' l/l ' LTING AcAD nL , 13194 doe No.: 13194 40%+ SLOPE SLOPE ANALYSIS MILE HI #1 B7, L10 PROFILE SECTION 35.0' EXISTING GRADE 5-14% SLOPE 25% SLOPE �70k'* A 0 OF AL4 t, *:4. TH* *0 KENNETH M. D S / CE -711 Atr JW11kOFE S100y _4pl SCALE:1 "=10' PREPARED FOR; RICHARD & TERRY DAVIS 22230 UPPER CANYON RD. EAGLE RIVER, AK 99577 FIELD BOOKS C010pu O: BOUNDARY MA": BMW STAKING CHECKED: KMD RJ DAM' 9 4 1 MIDI NW58 13194 PAGE 3 OF 3 \\Server\storage\WELL & SE C — Filed by Legal\Mite 11 j1 SD\Mile Mi Ili n 11ele i inc iulu—.=+ • i`— --- ..___.._.., �RcTERRq ARC 1 irimA CONSUI,TING, INC 1, s 212 E. 51" Ave, Anchorage, AK. 99503 Office (907) 868-3791, Fax(907)868-3793 Ew nM. es5i1—@j6 SOILS PERCOLATION TEST Performed for: Richard & Terry Davis Date Performed: Project: Mile Hi #1 B7, LIO TEST HOLE# TH 13-1 Depth Org/OL SM/GM —sp/gp pockets mod dense, trace of silt, sand increasing w/ depth & cobbles to 6" HOLE PRESOAKED 20- PRIOR TO TEST Kenneth CE SEE ATTACHED SITE PLAN FOR HOLE LOCATION Was Ground water encountered? NO What depth? NA Depth to water after monitoring? NO Date? 8/30/13 Reading Date Gross Time Net Time Depth to Water Net Drop 1 8/23/13 1:00 6" - 2 1:10 10 min 111/16" 45/16" 3 * 1:11 6" 4 1:21 10 min 1 12/16" 44/16" 5 1:22 6" - 6 1:32 10 min 114/16' 42/16" 7 * 1:33 - 6" - 8 1:43 10 min 114/16' 42/16' 9 1:44 6" - 10 1:54 10 min 114/16' 42/16' 11 * 1:55 6" - 12 2:05 10 min 1 15/16' 4 1/16' * Water Added Percolation Rate 2_4 (min/in) Pere Hole Diameter 6" Test Run Between 4 feet and 5 feet I, Kenneth M. Duffus, certify that this test was performed in accordance with all State and Municipal guidelines in effect on this date. TrOffirb Dritting i[og by DOC Co. dba SULLIVAN WATER WELLS P.O. BOX 670272, CHUGIAK, ALASKA 99567 • TELEPHONE 688.2759 OWNER OF LAND %< {i.,'_ r/i -:a1 j jf ,• r. ADDRESS 1 i%) ! i' a', ..... .i PO . t. LEGAL DESCRIPTION ' ° , i r l Zvi t r� "} F DATE - Started Ended j /,7"), PERMIT NUMBER KIND OF FORMATION DEPTH OF WELL j, -,j STATIC LEVEL OF WATER FF. DRAW DOWN FT. `r GALS. PER HR } KIND OF CASING From Ft. to Ft. " "'°fl' " { T ' ` From Ft. to Ft. From Ft. to Y` Ft. ! i s `` "i'" 1;11., t l ` From FL to Ft. From Ft. tomFt. From Ft. to Ft. From d i -. = Ft. to 1 Ft. f^ 'i s ' i, =n'; - r J From Ft. to Ft From Ft. to_Ft From. Ft. to Ft From 3 Ft. to Ft - t t-_. =''-'I From Ft. to Ft. From—LL—Ft. to Ft. " Ft. to Ft. From Ft. to `—<-`-` Ft !� , �� ' �- ' �'; ° From Ft. to FL From �i "l Ft. to f { -� Ft. f `'-.: ; <.. t:::.J From Ft. to Ft. From Ft. to Ft. lkL,.ri"� From Ft. to Ft. From 1 IFt. to Ft.'" a "`" t"' From Ft. to Ft. From j `? Ft. to_t Ft. !� ^ ='Jtt < t« �;rr From Ft. to Ft. From—Ft. to Ft.–� z �� '` ' �3- _. �"' r, , - �'�From Ft. to Ft. From r Pi `" Ft. to % i Ft. t i d ,`%r -_ 4:. -" ° From Ft. to Ft. From i Ft. to f `! Ft ;- '' -3 ", From Ft. to Ft. From Ft. to -Ft. : ' : ';"rt From Ft. to Ft. From t Ft. to Ft !' ! %`,F r `''� From Ft. to Ft . MISCL. INFORMATION: � R E C E I V E D RECEIVED ' OCT 51992 = Murticipaiay of Anchorage Dept. Health & Human Semi DRILLER'S NAME MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND HUMAN SERVICES P.O. BOX 196650, 825 "L" STREET, ROOM 502 ANCHORAGE, ALASKA 99519-6650 ON-SITE WELL SYSTEM (UPGRADE) PERMIT PERMIT NUMBER:SW920303 DESIGN ENGINEER:DUMMY COMPANY OWNER NAME:DAVIS RICHARD L & TERRY L OWNER ADDRESS:22230 UPPER CANYON DR EAGLE RIVER, ALASKA 99577 PARCEL ID:05020128 LEGAL DESCRIPTION: MILE -HI #1 BLK 7 LT 10 LOT SIZE: 56849 (SQ. FT.) NUMBER OF BEDROOMS: 2 THIS PERMIT: 2 THIS PERMIT IS FOR THE CONTRUCTION OF: WELL SYSTEM ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH: PAGE 1 OF 1 DATE ISSUED: 9/22/92 EXPIRATION DATE: 9/22/93 1. THE ATTACHED APPROVED DESIGN. 2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS 15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80). 3. THE FOLLOWING SPECIAL PROVISIONS. SPECIAL PROVISIONS: RECEIVED BY: ISSUED BY: n Z le - DATE: DATE: F- i November 3, 1970 Mr. Roberti. Hamann Hamann Construction Co. Box 617 Eagle River, Alaska 94577 Bear Mr. Hamann; Enclosed is your copy of the permit and the final copy which should go to Mr. Jones. I am sending it to you first, however, so that you can look it over and see if it is correct and either return it to mea for correction or forward it on to Mr. Jones if it lboks okay. Mr. Eastaugh took leave the day after this inspection for Jones and I don't know what the situation was only that he left a note that you were going to write up the information for us. Thanks a lot. Sincerely, Sue McKechnie Environmental Health Aide Enclosure. cme j G,-,ATER ANCHORAGE AREA BOROJ"`�H j -+HEALTH DEPARTMENT 327 EAGLE ST. ANCHORAGE, ALASKA 99501 279-2511 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM VIM 391 MAILING NAME ADDRESS �PHONE �� LOCATION-/�_l 0'/Gly �f'� LEGAL DESCRIPTION /li/O,/ Re SEPTIC TANK: NUMBER OF DISTANCE FROM WELL MATERIAL f`l COMPARTMENTS Yid 'AKv f /' i %G �D LIQUID LIQUID CAPACITY �!� �} GALLONS. INSIDE LENGTH �� INSIDE WIDTH DEPTH SEEPAGE SYSTEM: SEEPAGE PIT: NUMBER OF PITS OUTSIDE DIAMETER / OR WIDTH LENGTH A DEPTH__, LINING MATERIAL s DISTANCE FROM WELL �� i BUILDING FOUNDATION Q, / NEAREST LOT LINE O TOTAL EFFECTIVE ABSORPTION AREA (WALL AREA) -7/SQ. FT. TILE DRAIN FIELD: TOTAL LENGTH DISTANCE FROM WELL FOUNDATION NEAREST LOT LINE OF LANE-S� --= NU/P6���_S DISTANCE BETWEEN LINES TRENCH WIDTH IN. TOTAL EFFECTIVE ABEASQ. FT. LENGTH OF EACH LINEDEILE TO FINISH GRADE DEPTH OF FILTER MATERIAL BENEATH TILE N. ABOVE TILE WELL: C DISTANCE FROM s' WATER TYPE DEPTH BUILDING FOUNDATION. Z-24;�;' SAMPLE r NEAREST NEAREST �% SEPTIC ��. SEEPAGE / OTHER LOT LINE ze� SEWER LINE ,TANK SYSTEM CESSPOOL , SOURCES_ DISTANCEI: �f I I DIAGRAM OF SYSTEM DATE '4�;�-D a- u /GAABjj,T113-2'U xE'ATE �iANCHORAGE AREA 'OROUGH Case No. �/ % HEALTH DEPARTMENT 327 Eagle St. Anchorage, Alaska 99501 279-2511 SEWAGE DISPOSAL SYSTEM - APPLICATION & PERMIT {� � MAILING ADDRESS �Sd�, )j PHONE NO.���� NAME OF APPLICANT, ���i�� �+ j / R E S I D E N C E A D D R E S S It�l %i,`aI>SST.,T� eATIONOFINSTALLATION /47�� LEGAL DESCRIPTIO APPLICATION TO INSTALL: SEPTIC TANK L, SEEPAGE PIT t�— DRAIN FIELD , OTHER TO SERVE THE FOLLOWING FACILITY J)ev r—:-- �� LZ -e S &::-,i de/?6-le— FINANCED THROUGH TO BE INSTALLED BY_,11-11-VZ?Z11A1/-1 PERCOLATION TEST RESULTS THIS IS TO SERVE AS DISTANCI ANTICIPATED DATE OF COMPLETION BELOW TO BE FILLED OUT BY HEALTH DEPARTMENT , PERMIT TO INSTALL A AS DESCRIBED BELOW. SIZE OF UNIT TO BE SERVED ? AxlKdaL� /7�/���� ,SEPTIC TANK SIZE 1'OUd TYPEfTzE' SEEPAGE AREA TYPE DIAGRAM OF SYSTEM /hat I certify I am familiar with the requirements of Greater Anchorage Area Borough Ordinance No. 28-68 and that the above described system is in accordance with said code. DATE APPLICANTS SIGNATURE ,h E OCT 29 1970 - GREATER ANCPYORAGE AREA BOROUGH—HEALTH DEPA"MENT 'l i tl j a E I �- r ti • °EATER ANCHORAGE AREA BOROUGH HEALTH DEPARTMENT CASE N 327 EAGLE -STREET ANCHORAGES ALASKA 99501 Performed For Robert Hamamnn Date Performed 9/21/70 Legal bes,cription. Lot 0 Bloc 7 ivision Mile High Estates This Form Redr•ts,,a: So= Log xx ercolation Test Depth <r,; Feet Sol'l Char•_ tev i ;ties 9 10 brown silty sand (SM) gray sandy gravel (SW) f ti �I dark gray silty sand with scattered gravel (SM) Was r , t0, no Location Sketch ME I ONE N No Mal 1 N E-1 erc7 3 E ,i ,se; ',n.� 174 1 : Seepage Pit _ _ Dra_n iie�d DPDL ;f Inlet i)e^,th ;o Bottom Of Pit rer,c'; COMMENTS: - 127 square feel of drainage area is require per e room, et - - -..� _ .. crib bottom at _R . Onth r Test Performed By: R, E. Carlisle These recon�-,endations are comput <1 from '' -- visual observation and based on tl,, uni- DBtd Certified A Pied classification system. i y: National Testing Service Inc. Date: �f $ • '� Municipality of Anchorage On-Site Water and Wastewater Program a (907)343-7904 Dery CERTIFICATE OF ON-SITE SYSTEMS APPROVAL Parcell.D. 050-201-28 1. GENERAL INFORMATION Complete legal description _MILE HI #1 BLOCK 7, LOT 10 Expiration Date: /a - 3 O / S� Location (site address) 22230 UPPER CANYON DRIVE EAGLE RIVER AK 99577 Current Property owner(s) RICHARD & TERRY DAVIS Day phone Mailing address Real Estate Agent 35467 KALIFORNSKY BEACH ROAD KENAI AK 99611 2. TYPE OF DWELLING: ® Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) Day phone 3. NUMBER OF BEDROOMS: 2 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well ® Individual Individual Water Storage ❑ Holding Tank ❑ Community Class _ Well ❑ Community ❑ Public Water System ❑ Public Sewer ❑ WaiverNariance request for: Distance: COSA to be released to the unless otherwise requested by the engineer. COSA Fee $ 4,25D 1e' Date of Payment 9mg �✓-3 2p Receipt Number 3 5ai7 Q COSA# Date: Waiver Fee $ Date of Payment Receipt Number Waiver # 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm ARCTERRA CONSULTING, INC. Phone 868-3791 Address 20441 PTARMIGAN BLVD., EAGLE RIVER, AK 99577 Engineer's Printed Name KENNETH M. DUFFUS Date 9/23/13 Engineer's Comments: This investigation was completed in compliance with ADEC and MOA regulations. The assessment of the condition of the well and septic applies only to the conditions as of the day tested. The flow and absorption rates may change due to subsurface conditions that may not be observed from the surface, changes inland use, local soil characteristics, groundwater levels that may fluctuate during the year and the water usage of the family being served by the system. The operational life of all well and septic systems are subject to these various and dynamic characteristics and are outside the control of the evaluator of the well and septic system. Therefore, ArcTerra can not give any estimate of how long a system will function satisfactory for current or future ��, <�%A occupants or can ArcTerra guarantee that no unseen encroachments, deficiencies or discrepancies exist. 6. DSD SIGNATURE ► ' m6 xE:n ,; u/eeu: M +� System #1 Approved for bedrooms. "'a/ System #2 Approved for bedrooms. Disapproved. Conditional approval for bedrooms, with the following stipulations: )F VVXT ,R AND 'IS IN By: Original Certificate Date. Mint Th un a,y horage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the rep%sentations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSAbluesheel 10-10-12doc If more than 1 septic system is on the lot: COSA Checklist # _of _ Structure served by this system _ Certificate of On -Site Systems Approval Checklist Legal Description: MILE HI #1 BLOCK 7, LOT 10 Parcel ID: 050.201-28 A. WELL DATA Well type PRVT If A, B, or C provide PWSID # Date completed 911992 Sanitary seal (YIN) Y Total depth 240 ft. Cased to 20 ft. (Into Bedrock) FROM WELL LOG Date of test 911992 Static water level 55 ft. Well production 0.5 g.p.m. WATER SAMPLE RESULTS: Coliform NF-&- colonies/100 mL Nitrate O q5 mg/L Arsenic: No ug/L Date of sample: 91412013 B. SEPTIC/HOLDING TANK DATA Tank Type/Material SEPTIC I STEEL Tank size 1000 gal. Number of Compartments 2 Foundation cleanout (YIN) Y Depression over tank (YIN) N Date of pumping NA -New Tank Pumper C. ABSORPTION FIELD DATA Date installed 911 812 01 3 Soil rating (g.p.d./ftz or ftZ/bdrm) 1.2 Length 21 ft. Width 2 ft. Total depth 11 ft. (Measured 9/19/13) Eff. absorption area 252 ft2- Date of adequacy test NA- NEW FIELD Results (Pass/Fail) _ Well Log (YIN) Y Wires properly protected (YIN) Y Casing height (above ground) 24+ in. AT INSPECTION 8123113 83 ft. 0.44 9-P M. Collected by: ARCTERRA Date installed 9118113 Cleanouts (YIN) Y High water alarm (Y/N) N System type DEEP TRENCH Gravel below pipe 6 ft. Monitoring tube Y Depression over field N Fluid depth in absorption field before test _ in. Water added_ gal. Elapsed Time: _ min. Final fluid depth in. Absorption rate >= For 2 bedrooms New depth in. Any rejuvenation treatment (past 12 mo.) (YIN & type) N If yes, give date --- D. LIFT STATION Date installed "Pump on" level at _ in. Datum Size in gallons Pump off' level at _ in. Cycles tested E. SEPARATION DISTANCES WELL ON LOT TO: Septic tank/lift station on lot 100'+ Absorption field on lot 100'+ Public sewer main 75'+ Sewer /septic service line 25'+ Animal containment areas 50'+ SEPTIC/HOLDING TANK ON LOT TO: Manhole/Access (Y/N) High water alarm level at Meets alarm & circuit requirements? On adjacent lots 100'+ On adjacent lots 100'+ Public sewer manhole/cleanout 100'+ Holding tank 100'+ Manure/animal excrete storage areas 100'+ Building foundation 5'+ Property line 51+ Absorption field 5'+ Water main 10'+ Water service line 10'+ Surface water 100'+ Wells on adjacent lots 1004 ABSORPTION FIELD ON LOT TO: Property line 10'+ Building foundation 104 Water main 104 Water Service line 101+ Surface water. 1004 Driveway, parking/vehicle storage 3'+ Curtain drain 50'+tNONEKNOWNI Wells on adjacent lots 1004 F. COMMENTS G. ENGINEER'S CERTIFICATION i certify that i have determined through field inspections and review of determined through field inspections and review of Municipal records that inspections and review of Municipal records that the above systems are in Municipal records that the above systems are in conformance withMOA above systems are in conformance with MOA COSA guidelines in effect on conformance with MOA COSA guidelines in effect on this date. COSA guidelines in effect on this date. on this date. Engineer's Printed Name KENNETH M. DUFFUS Date 9123 113 COSA brown sheet 10-10-12.doc —�� � �� OF AZ 4 / �A(1 Ti/ T �rQ KEV NNET 't. DVFLI:) / i 9/ Illr w / E'`YOFEc_SlObab AI Municipality of Anchorage s , e, Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 Elmore Street P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907)343-7904 Water Well Advisory Certificate of On -Site Systems Approval (COSA) 4 131495 During a recent COSA on-site inspection and test of the potable water supply well on Block 7, Lot 10 of Mile High 41 subdivision, the well's productivity was determined to be 0.44 gallons per minute. The minimum well productivity required by this Department (AMC 15.55) for a 2 -bedroom residence is 0.2 gallons per minute. Although the subject well currently exceeds this minimum requirement, all parties concerned are advised that the production capacity of the well may fluctuate. Restriction of non-critical water uses such as washing cars and watering lawns and gardens may be required. This advisory must be attached to all copies of the subject Certificate of On - Site Systems Approval. RR jm e6tl I'LOOA �¢tv.;uwdrtnl p`,tL plll[Wc cWIW i[u:R AswuEG) SCNW: JISIRICT �� fAONt SYMNC 4:1BIA( \ 9GE 6-IiLN.G WWACK \ REAR :Aa,IWc s VAO, CANY0IVDRIVE •V �,ye L =,3p. N86° 00' OOnE LR`z0 1T. R=355.00 47A 24'00 o o-� Cos 0 v0. ... .'. ": SHED n GARAGE Q .. O WELL +nl ^VY / EMSTNGS A HOU5E b 0' ti a N ry0 5� 9 295.81. 5 6 UNDER NO CIRCUMSTANCES SHOULD AN AS -BUILT BE USED FOR CONSTRUCTION OR FOR ESTABLISHING BOUNDARY OR FENCE ONES. .THE SURVEYOR TAKES RESPONSIBILITY FOR THE INITIAL TRANSACTION ONLY AND ASSUMES FINANCIAL LIABILITY ONLY FOR THE COST OF THE SURVEY. LISTED DISTANCES PREVAIL OVER SCALING. REPRODUCTION MAY CAUSE ERRORS IN SCALE, LF,T SURVHY SURVEY TYPE SYMBOLS ' rGUNDA11011 AS -BUILT • SET REBAR � � DRAINAGE D ASPHALT [I nNAL STRUCTURE AS -BUILT [. HOT PLAN AS -BUILT LOT SUR'•EY TOPG[ltARRr In G FOUND REBAR g_g._e. WOOD FENCEI ° ".� CONCRETE ... ... ... DO a ASSUMED ELEV. -k( I( K METAL FENCE ® .._':_BUILT . . No CORNERS SET 2 KCERTRCATM AS- ILT NO CORNERS 9T WOOD DECK l' P.,_ i PLANS & LOT SURVEYS NOTE: { IT -:i THE RESPONSIBILITY OF THE BUILDER OR OWNER, PRIOR TO ONLY THOSE IMPROVEMENTS ABOVE GROUND AND VISIBLE WILL BE Ci;,STRUCTION, TO VERIFY PROPOSED BUILDING GRADE RELATIVE SHOWN. FENCES, WELLS, SEPTIC CLEANOUTS. SIDEWALKS, DRIVEWAYS. TC-IwSHEO GRADE AND UTILITY CONNECTIONS AND TO DETERMINE ETC., ARE SHOWN IN THEIR APPROXIMATE LOCATION, ONLY. SNOW T}-_'. EXISTENCE OF ANY EASEMENTS, COVENANTS OR RESTRICTIONS MAY PREVENT SOME IMPROVEMENTS FROM BEING SEEN AND LOCATED. Ws- .H DO NOT APPEAR ON THE RECORDED SUBDIVISION PLAT. ALL DISTANCES ARE RECORD UNLESS OTHERWISE NOTED. SU"'jEY CERTIFICATION .�.,�`�*�I •.•�E OF fq� Prepared by Robert E. Johns, Jr. & Assoc. PLG"LAN I^-�„=..n �mdtl Ndw gDw<ar wv.wd •, ••'�P,.• ""'• '�j nal Land Surveyors Professional aw, NI I:aw Iw,d tt WIM. tll of N• 10uml. . rr__ , ! _ ♦� 1700 Brink Drive. m A_ -4 m w wM a m use r J��' ! ANCHORAGE, ALASKA 99504 Scale: ill = 601 Rec. Lot S.F. Rec. Plat File No. w-aUI mr th .,, . / - FGL, . TJN AS -BUILT i., n..bY m.e 1 •w ••. ...... / Checked e.By .: A. -mw ir«r w m fau MI 1nl al! MUI M M. / • .............0 •% Date Surve d: " 09/23/13 Drawn 6 REJ J 6J M K ...- Blom. - e memwelm w wd.n n..r:.' • "n1••• ROB . OHNS,,J r , Drawn: Grid: W.O. nom^ ee"si° .•°.'"'°°tly^"I• • p '• AAF Date 09/23/13 NW058 13-493 FINAL STRUCTURE AS -BUILT •�91w �' !��2�--CJ '• ar.� •yJ• + •�9••••, I, ReGv: E. .Mot i.. •WtY uyllr Nd[ . t_m W. M end M. mun ♦. �p •• •�, e, ......... • Legal Description: Lot 10 BLOCK 7 v tn�'mm.nweeMmwt. www uw� d _ Pr -a�5•.•• •, Ofe991000{ �4��ro�. MILE HI #1 Page 1 of 1 Poet, Jeff W. From: Brent Western [bmw.kndeng@ak.net] Sent: Friday, September 27, 2013 8:06 PM To: Poet, Jeff W. Subject: Re: Crystal Repo rtViewer[ 1 ]. doc Jeff, Per our conversation today --the surveyor did not show the driveway correctly. He didn't adjust his driveway from his previous as -built before the septic was installed. The inspection report septic as -built is correct -- the field is NOT in the driveway and has barricade around the end to prevent parking / driving over it. Thanks, Brent M. Western ArcTerra Consulting, Inc. 907-440-4601 Cell 907-868-3792 Office 907-868-3793 Fax "Quality is never an accident; it is always the result of high intention, sincere effort, intelligent direction and skillful execution. It is the wise choice of many alternatives." --William A Foster On Sep 27, 2013, at 4:01 PM, Poet, Jeff W. wrote: <CrystalReportV fewer[ I ].doe> 9/30/2013