Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutMONTGOMERY LT 4Montgomery
Lot 4
#051-193-03
Municipality of Anchorage
Development Services Department
©}
Building Safety Division
On-Site Water and Wastewater Program, 4700 S. Bragaw St.
1
P.O. Box 196650 Anchorage, AK 99519-6650 Page i of->
www.ci.anchorage.ak.us (907) 343-7904
ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
Permit Number: _��a 70 6 1 PID Number: 05-1—M-03
Name: /
Veit rlcl SJelk/rWastewater System: ❑New Upgrade
Atltlress' n
3 14 -Street Ailriwe (7'j6/
ABSORPTION FIELD
Number of Bedrooms: \
Phone: 'a S -Sn
{a, L,,,
Deep Trench p Shallow Trench p Bed ❑Mound
C;i/
❑ Other:
LEGAL DESCRIPTION
Soil Rating:
Total Depth from original grace: •�/
Block: Lot:
TownsltiP: Subtlivision�
• GPD/Ft'
to pipe bottom from ginal gra�E, Ft.
De
/ Ft.
Gravel depth beneath pipe:
Range;
atldetl abovetanginal �dpth
11'• 6
Ft.
Gravel Length
a�
Well; ❑ New El Upgrade
e Ft.
Gravel width:
Ft.
Number of lines: Distance between lines:
Cl as ¢a4on (P vote. A, 8, ):• y/- Total DepN: Cased to.
KfS//r / E /W�t'!e' FL Ft.
Ft.
Total absorption area: ^ �D
'
Ft.
JPijye Mat ep�'/aI Q (/]
Dnller. Date Dniled: Static Water Level:Installer.
Ft.
cJS) Ft?
yy //
7�wGPdXCE4U'�T/✓/G
Dale InsWlletl:'-7 /f� /
—�"V7
Yield: pSet an Casing Above Grountl:
!
GPM Ft. Ft.
TANK
SEPARATION DISTANCES
l(Septic ❑ Holding ❑ S.T.E.P. ❑ Other:
o
Septic
Tank
ift
tion
Holding
Tank
ubifc/Pnvate
Sewer Line
Manufacturer:
Cevy/Ji' �7�' LeST-/L
capacdy:
C.i--4B Gal.
I��t
--i
+-1 t
(�J �.�°"
Material: �DP�
Nyyper of Compartments:
ol!ter
+
ad
LIFT STATION
'
lze: an acturec`Pump
on' level at: "Pum oP
High water alarm aCin.
in.
in
RRemls
_y�Pump
w
Make a Electdpl Inspections perfgmed by:
�
S T/C a/7I: LJASBENCH
MARK
�v'Location
b�,�
and Deschpbon:,�
,W u, �.D,psunned
`7
Elevation:
Ft.
En
P �..OF
S& S ENGINEERING
Inspections performed by: 17034 Eagle RiverLoop Rad, NoD2f{4 at 3 r L
a es: 1 T
d µ9. 1
s,. ».J.
'
2nd ��-Q "y^
�•.p.;..
Development Services Department Approval
ROBERT C. COWAN.....
yj ���
CE
Reviewed and approved b
PP Y Date:
e.. 11'00)1Ilk,y'ROFESS%�1`*�
-8801 @'
741t�
r
PERMIT No. SW040201
PAGE 2 OF 3
Municipalit of Anchora e
DEPARTMENT OF HEALTH AND HUMAN SERVICES
ENVIRONMENTAL SERVICES DIVISION
P.O. Box 196650 • Anchorage, Alaska 99519-6650 • Telephone: 343-4744
ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
LEGAL LOT 4, MONTGOMERY S/D P.I.D. N0. 051-193-03
LOT 14-/
SHERMAN
STREET
2'
POWER EASEMENT
w
cn
z
>
>
O
0
0
�
a
a
w
>a
�
U
O
�
c�
J
J
3
0 SPO
o
IL
0-
DECK
41AJ,T
EXISTINGSEPTIC HOUSEAREA-NEW TRENCH (RILINGNEWATH
FOUNDATION) DELI & DBL2A �ALT• SITE
TFCO
ST1 �
ON
HDPE �SEPTICATANK \ 10' UTILITY EASEMENT
— _ _ _ — _ — _ _ — —— _ — — _ _ — _ — ----�
SEPTIC
AREA
LOT 9
LOT
3
SCALE: 1" = 30'
p \ ROBERT C. COWAN J `4
��C, ^ a-8901 r, �R
PERMIT No. SW040201
PACE 3 OF 3
DEPARTMENTUOF pHEALTH ANDhHUMAN SERVICES
ENVIRONMENTAL SERVICES DIVISION
P,0. Box 196650 •Anchorage, Alaska 99519-6650 • Telephone 343-4744
ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
LEGAL LOT 4, MONTGOMERY S/D P.J.D. No. 051-193-03
ST1 ST2 99.8'
FINAL GRADE 2" INSULATION
NEW
96.8' 1000 GALLON
POLYETHYLENE 96.5'
SEPTIC TANK
A B
FCO 9.0' *1.0'
_ST _1 9.0 36.5'
ST2 1 2.0 37.0'
TMT 14.0' 38.0'
DBL1 13.5 35.5'
DBL2 13.0' 33.5'
C01=99.1' C01 14.0' 26.5'
CO2=98.8' CO2 32.0' 12.5'
NTT —1 26.0' 16.0
* = HOUSE OFFSET
FINAL GRADE -72" INSULATION
C01=96.5'
SR CO2=96.5'
N. T. S.
C;ice /t • h i
MT1=91.5'
C;,
MT
.
NO WATER FOUND /A �}� Rp9OT C. AN
84.5' B.O.H. r�tPsr��, CE-w0i :r}
I
S
Municipality vAnchorage (ENGIN
rvi $ A
Development Services Department
Building Safety Division
ri On -Site Water and Wastewater Program _ _
4700 South Bragaw St. p 3 ROBERT G COWAN
P.O. Box 198650 Anchorage, AK 99519-6650 c^
www.muni.org/onsfle e��.''. C:"8801 {�'4
(907) 343-7904..
Z�d`�1 V
Soils Log - Percolation Test
Performed For: JC` J K t +J57 A
Date Performed:
Legal Description: Ln -r ii W N" c-6 M e9L -j S1 "7 -
man
Depth
(Feet) ga_&, -4l6S
I-
2-
3- 16-M
..
8- •'O
9-
10-
11-
12-1
-
10-
11-12-
o
15- ,
16-
17-
18-
19-1
6-
17-18-19-
Immuvevincnl HERO HOLE DIAMETER
TEST RUN BETWEEN FT AND C_FT
COMMENTS
PERFORMED BY:, S43 E/Jaij PAl i. -I CERTIFY THAT THIS TEST WAS
PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUID LINES IN EFFECT ON THIS DATE, DATE:
I I 1 1 1
WAS GROUND WATER
ENCOUNTERED?
IF YES, AT WHAT DEPTH? ^
L
Depth to Water After
O
Monitoring? ,Day
P
E
Date:7 ,r o y
Immuvevincnl HERO HOLE DIAMETER
TEST RUN BETWEEN FT AND C_FT
COMMENTS
PERFORMED BY:, S43 E/Jaij PAl i. -I CERTIFY THAT THIS TEST WAS
PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUID LINES IN EFFECT ON THIS DATE, DATE:
_-�
•Ems
_--��
aTLi
Immuvevincnl HERO HOLE DIAMETER
TEST RUN BETWEEN FT AND C_FT
COMMENTS
PERFORMED BY:, S43 E/Jaij PAl i. -I CERTIFY THAT THIS TEST WAS
PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUID LINES IN EFFECT ON THIS DATE, DATE:
MUNICIPALITY OF ANCHORAGE
Development Services Department
On -Site Water & Wastewater Program
4700 South Bragaw Street
P.O. Box 196650, Anchorage, AK 99519-6650
(907) 343-7904
ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT
Initial
Permit Number: SW040201
Legal Description: MONTGOMERY LT 4
Design Engineer: 0003 S & S Engineering
Owner Name: Verna Jenkins
0 xot(
Date Issued: Jun 17, 2004
Expiration Date: Jun 17, 2005
Parcel ID: 051-193-03
Site Address: 022630 SHERMAN ST
Lot Size: 13464 SQ. FT.
Owner Address: 1342 H STREET Total Bedrooms: 2 Permit Bedrooms: 2
ANCHORAGE , AK 99501-4361
This permit is for the construction of:
❑✓ Disposal Field 0✓ Septic Tank Holding Tank [:] Privy E] Private Well ❑ Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ).
3, The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling
(907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
must be either: A. Open and closed on the same day.
B. Covered, sealed, and heated to prevent freezing.
5. The following special provisions.
ADDITIONAL TEST HOLE NEEDS TO BE PERFORMED DURING CONSTRUCTION IN THE LOCATION OF THE
PROPOSED ALTERNATE SITE. THE TEST HOLE TO BE PERFORMED DURING CONSTRUCTION WILL
DETERMINE WHETHER THE ALTERNATE SITE WILL REQUIRE A STANDARD SEPTIC SYSTEM OR AN
ALTERNATIVE WATEWATER SYSTEM. THE ASBUILT SITE PLAN NEEDS TO SHOW WHAT TYPE OF SEPTIC
SYSTEM REQUIRED FOR THE ALTERNATE SITE, ALONG WITH THE TEST HOLE.
Received By:
Date:
C /1 y/o'y
Issued By: i 11 Date: 4� o
-hoe Municipality of Anchorage`
P.O. Box 196650 • Anchorage, ,Vaslai 99519-6650 • Tclephone (907) 343-8301 • liax (907) 3438200
4700 6ragxw Strcet • Anchorage, Alaska 99507 s a v c r v
aINZmuni.orlr
Mayor Mark Begich
Building Safety Division
6/18/2004
S&S Engineering
17034 North Eagle River Loop
Eagle River, Alaska 99519
Subject: Waiver Request for Montgomery Lot 4
Waiver Request 4WR040040
Parcel ID 4051-193-03
Dear Bob Cowan:
Your request for a waiver of the required 10 feet horizontal separation from the
absorption field and septic tank to property line has been approved. The approved
separation distance is 1.0 feet.
This waiver approval applies to the existing absorption field and septic tank to
property line separation only. Any future upgrade to the on-site wastewater disposal
system will require all separation distances be met or another approval from this
department.
If there are any further concerns or questions regarding this waiver, please call our office
at 343-7904.
Sincerely,
J Goodall
ivil Engineer
On -Site Water & Wastewater Program
Community, Security, Prosperity
Municipality of Anchorage
Development Services Department
Building Safety Division
On -Site Water and Wastewater Program
4700 South Bragaw St.
P.O. Box 196650 Anchorage, AK 99519-6650
www.ci.anchorage.ak. us
(907) 313-7904
ON-SITE SEWERPNELL PERMIT APP;JcATION
FOR A SINGLE FAMILY DWELLING
Parcel I.D. 1_); I - If? 3'0T Permit Number SW
Property owner(s) ��eYY1a (JE✓1 k lns
Mailing address (1) Ia3I ti,',��,be��N L! rG/C
Mailing address (2) Afy4w,,ay
M9
Day phone '�Q3' 5009
Zip Code g0i3-/5
Legal description (Lot, Block & Sub'd.)/03/ -4.
! %_17190/ iL4 --f/Y
J �
Legal description (Section, Township & Range)
LotSize� 13i�6 Acre /Sq.Ft
Number of Bedrooms
THIS APPLICATION IS FOR:
Sewer Only ❑
Well Only
❑
Sewer and Well ❑
Water Storage
❑
Sewer Upgrade
THIS PROPERTY CONTAINS:
Hot Tub ❑
Jacuzzi
❑
Swimming Pool ❑
Water Softening Unit
❑
Therapy Pool ❑
I certify that the above information is correct. I further certify that this application is being made for a
Single Family Dwelling and is in accordance with applicable Municipal Codes.
S & S ENGINEERING
17034 Eagle River Loop Road No. 204
raffia River. Alaska 99577.
(Signature of property owner or authorized agent)
Permit Fees:
Date of Payment:
Receipt Number:
(Rev. 12/00)
h`Go.J°
�r n /0
0 S-3763
Fees:
Date of Payment:
/-7j� o.r
6 A,) /') y
Receipt Number: O S 3 3- 6 3
EngineexiHG ROBERT C. COWAN, P.E.
uau
ASA CIVIL ENGINEERS
(907) 8942979
FAX (907) 694-1211
June 3, 2004
HEALTH AUTHORITY
APPROVALS
MUNICIPALITY OF ANCHORAGE
Development Services Department
P.O. Box 196650
SEWER&WATER
Anchorage, AK 99519
MAINDUENSIONS
REFERENCE: Lot 4, Montgomery Subdivision
SEWER& WATER
INSPECTION
It is requested that you issue a permit to replace the existing septic tank with a new
1000 gallon septic tank and install a new trench to serve the existing two bedroom
dwelling on the referenced property.
ENGINEERINGSTUDIES
AND REPORTS
A test hole was excavated, and the approximate location of the test hole is located on the
attached site plan. At the time of excavation 5/28/04 no water was found. After
monitoring, ground water was not found.
WELL INSPECTION
&PLGWTEST
We do not anticipate any adverse effects on neighboring wells, septic systems, reserve
areas or drainage patterns by the installation of the proposed septic tank. The installation
of this trench will not prevent any future development on any of the adjacent properties.
SITE PIANS
If you require additional information, please contact us.
Sincerely,
ROAD DESIGN
_
R/V ?ow6.�E.
SOILTEST
RCC/b]]
Enclosure
PERCOLATION
TEST
STRUCTURAL&
MECHANICAL
INSPECTIONS
ONSITE
WASTEWATER
DISPOSALSYSTEM
DESIGN
17034 NORTH EAGLE RIVER LOOP • SUITE 204 • EAGLE RIVER, ALASKA 99577
S&
June 10, 2004
ROBERT C. COWAN, P.E.
ROBERT A. SHAFER, P.E.
CIVIL ENGINEERS
(907)694.2979
FAX(907)694-1211
HEALTH AUTHORITY
APPROVALS
MUNICIPALITY OF ANCHORAGE
Development Services Department
SEWER&WATER
P.O. Box 196650
MAIN EXTENSIONS
Anchorage, AK 99519-6650
SPPECTION�R
REFERENCE: Lot 4; Montgomery Subdivision
INS
Request you grant a waiver on the referenced property for the horizontal separation
ENGANDSSTUDIEs
distance between the new septic tank and the south line at 1 foot, and the
EIEPOR
REPORTS
property
new leachfield and both the south and the west property lines at 2 feet.
Please be advised that the house rests on a non -conforming piling and cinder block
WELL INSPECTION
&FLOWTEST
foundation.
We do not anticipate any adverse effect on the referenced property or the adjacent
properties.
SITE PLANS
If you require additional information, please contact us.
ROAD DESIGN
Sincerely,,
SOILTEST
/)V/Z,
Robert C. Cowan, P.E.
RCC/ts
PERCOLATION
TEST
STRUCTURAL&
MECHANICAL
INSPECTIONS
ON SRE
WASTEWATER
DISPOSALSYSTEM
DESIGN
17034 NORTH EAGLE RIVER LOOP • SURE 204 • EAGLE RIVER, ALASKA 99577 .
1 "
= 40'
DESIGN
SITE
-PLAN
N W Cn �I
�
aw
nonA
S AL
oda
�sr
ar,o
i
N 0 0 0
�
ama�
N
S.az
"
0*
xmr
�-
Z o m
��sA lYP
za
�mm-0
A Ro
�om
<
A
C Orr
p�
00
mom.
Q aa�
3
\Nom
�v
cn�ol�
.0> A^ nn°—'
mz
ONm
o = O
U7
9ac
no ypo
d
m Q
;Q
C
Ingo
imcm ZN
4
m N a
/
nco
O
xzo
g
�C
m T✓ m 0
N
I
V'
o
_r
x
GRAVEL DRIVE
n
ro' µ
150' WELL RADIUS
-'
o
/p (APPROX. LOCATION) -o
Qi
0
of
p,
y
to
oa
F
113Mo
S�IOda
m
Q
o
i
c� oi
mz
F�
Z i
o.mXp`
Q//
aZ
>
s
D_p
r�
K�mn
O
0,
0,
v7
A�
r
>�
--�--- -=moo
m
Q
r,
o� C
@
�`.,
V
I,F\
•a4
e.G�e
O •�ia+A
rn
014
_� _________
!,
t" =
40'
DESIGN
SITE
-PLAN
N W Ui J
0
ids
AL
.0
Z.0
r^A
O fTl M
F•--1
m
hl
zo
oosm
tii
,
,
Gi fTl fTl -O
(7
pt.d
�+JJ
+'Ox
SADrO �•�
�om
<
'mho b
o_
yc F
w v_N d m
r o^
0Fm
Q Yo aA
\ N 0
U' 1
NNU, ?
~ Ike
CACA
m
N
Mom_
D
m
yaFv�, $n
zio�
Z7 O
~
s10
ODF
µ
n
2f
Nod
GRAVEL DRIVE
�
O
m
aN
s
rn C7
a�
w
150' WELL RADIUS
(APPROX. LOCATION)-
Z'
LED
1
"1�3M .00I
c;
�F�`
01
m
A
5(110Va
r
Pq0
m
Q
<
°o,
n
I-�--�I
N
y
D
Z ,
x o
m
;Econ
o
z
FAZM m
m
<< o
m0
0 A
o
�N>
m u
O
z
Dn
y
wz,
It
o.= o ' I�AdtB
j.n 11
Municipality of Anchorage
Development Services Department
Building Safety Division
On -Site Water. and Wastewater Program
4700 South Bragaw St,
P.O. Box 196650 Anchorage, AK 99519-6650
www.muni.org/onsite
(907)343-7904
Soils Log - Percolation Test
r_
Performed For: V o C
Legal Description:
Z.tj'j-
Depth
Depth to Water
Net Drop
(Feet)
G
1-
z-
3-
r®
4-
5-
O .
10 3
6
�TM7-
y- 0
10-
0
11-
12- 0
13-
14-
Is-
16 -
17 -1
3-
14-15-
16-
17-
M
n ROBERT C. COWAN i
)�cl. CE -8801
l,.
I (iL,r/7r 1� WAS GROUNDWATER yy��
ENCOUNTERED?
s
IF YES, AT WHAT DEPTH? L
Depth to Water After .tel O
Monitoring? /
Dale: /p 4
Reading
Date
Gross Time
Net Time
Depth to Water
Net Drop
ASoR�C
G
Ci-
�o
r®
7�
10 3
4
10
r o
4
)1
1 1l2"
"
SZ)
io
Io,,(2'
-,
(00
J0
1 ((o' ''
4°
PERCOLATION RATE ( (minmeelinc) // PERC HOLE DIAMETER
TEST RUN BETWEEN FT AND (p FT
COMMENTS JJ
PERFORMED BY: y S CA.lis % A.ICTELf IrJ%y I CERTIFY THAT THIS TE
PERFORMED
W
PERFORMED IN ACCO DANCE WITH ALLSTATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: 47 '7 A �0 (
S&
HEALTHAUTHORITY
APPROVALS
SEWER&WATER
MAIN EXTENSIONS
SEWER&WATER
INSPECTION
ENGINEERING STUDIES
ANDREPORTS
WELLINSPECTION
&FLOWTEST
SITE PIANS
ROAD DESIGN
SOILTEST
PERCOLATION
TEST
STRUCTURAL&
MECHANICAL
INSPECTIONS
ONSITE
WASTEWATER
OISPOSALSYSTEM
DESIGN
ROBERT C. COWAN, P.E.
CIVIL ENGINEERS
(907)694-2979
FAX(907)694-1211
ON-SITE WASTEWATER DISPOSAL SYSTEM
CONSTRUCTION PRACTICES
and
MATERIAL SPECIFICATIONS
REFERENCE: Lot 4, Montgomery Subdivision
June 3, 2004
GENERAL:
1. The scope of this project includes the replacement of the existing septic tank
with a 1000 gallon septic tank and installation of a new trench to serve the
existing two bedroom residence located on the referenced property.
2. Construction shall be in accordance with the approved site plan and design
drawings, Municipal permit with any special provisions or conditions, and all
applicable State and Municipal Wastewater Disposal Regulations.
3. The contractor shall be responsible for obtaining any necessary underground
utility locates.
4. Unless specifically agreed otherwise, the property owner shall be responsible
for final grading areas subsequently depressed from soil settling.
5. Contractors installing wastewater disposal systems must be certified by the
Municipal Health Department for system installations. Owners installing their
own systems must also receive prior approval from the Municipal Health
Department.
SEPTIC TANK INSTALLATION:
1. A septic tank is to be constructed by a certified septic tank manufacturer.
Construction shall include two 4" cleanouts for pumping access.
2. The septic tank shall be sufficiently bedded to prevent settling or shifting of
the tank.
17034 NORTH EAGLE RIVER LOOP • SURE 204 • EAGLE RIVER, ALASKA 99577
Page 2
Lot 4, Montgomery Subdivision
June 3, 2004
3. All standpipes on the septic tank shall extend a minimum of 12 inches above final grade.
4. Septic tanks installed with less than 4 ft. of cover shall be insulated.
5. A foundation cleanout shall be installed one to four feet from the building foundation. In
the line between the tank and the leachfield there shall be two adjacent cleanouts (unless
an effluent pumping system exists within the septic tank). These cleanouts shall be
located on undisturbed soil not more than 10 ft. from the tank. The first cleanout, in line,
shall be to clean toward the leachfield. The second cleanout shall be to clean toward the
septic tank.
6. Final grading over the septic tank shall be such that a positive slope exists away from the
septic tank.
ABSORPTION TRENCH/DRAINFIELD INSTALLATION:
1. Excavate the proposed trench to the dimensions shown on the design. The bottom of the
excavation shall be within 2 inches of level. If the sidewalls of the excavation become
smeared, they must be raked or scratched (ruffed -up) before gravel (sewer rock)
placement.
2. Once the gravel is installed, the distribution pipe is to be installed level with the
perforations faced downward. Gravel is then to be placed over the distribution pipe to
provide a minimum of 2 inches of cover over the pipe.
3. A silt barrier must be installed between the final gravel layer and the native soil backfill.
Ensure the silt barrier covers the entire gravel surface before placing backfill.
4. Monitor tubes shall be of four (4) inch diameter, installed approximately in the locations
shown on the design, and extend a minimum of 12 inches above final grade. The portion
of the monitoring tube extending through the gravel shall be perforated from the bottom of
the trench to the invert of the distribution pipe. This is equivalent to the effective depth of
the gravel as noted on the design.
5. Backfill over the final gravel layer must not be less than twenty-four (24) inches.
Insulation must be installed when the backfill depth is less than thirty-six (36) inches. The
finish grade over the trench must be mounded to prevent the formation of a depression
after settling.
Page 3
Lot 4, Montgomery Subdivision
June 3, 2004
MINIMUM MATERIAL SPECIFICATIONS:
Any septic tank proposed for installation must be constructed by a Municipal approved
septic tank manufacturer.
2. The following pipe materials are approved for use in septic system installations in the
Municipality of Anchorage:
Type of Pipe Perforated Solid
Cast Iron
Yes
Yes
ASTM D3034 (PVC)
Yes
Yes
ASTM F810 (HDPE)
Yes
No
ASTM D2662 (ABS)
Yes
Yes
Use of a type of pipe other than listed above must be approved by the inspecting engineer.
3. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical
Company Styrofoam HI or equal).
4. Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Femco, or
equal).
5. A permeable nontoxic silt barrier (Typar 3401, Mirafi 140N, or equal) must be installed
between the final leachfield gravel layer and the native soil backfill.
6. All leachfield gravel (sewer rock) shall be 0.5"-2.5" screened gravel with less than 3%
passing the #200 sieve.
7. When sand is being used as a filter material, its gradation specifications must conform to
current M.O.A. or D.E.C. requirements, which ever requirement applies.
Page 4
Lot 41 Montgomery Subdivision
June 3, 2004
INSPECTIONS:
Typically there will be a minimum of three (3) inspections required during the installation of the
wastewater disposal system. These inspections will occur as follows:
The first inspection must be conducted after the excavation of ditches, pits,
trenches, or beds and before the installation of any gravel. A septic tank may be
set in place, but may not be backfilled before this inspection.
2. The second inspection must be conducted after the placement of the silt barrier,
gravel, distribution lines, standpipes, cleanouts, and insulation, but before the
placement of any other backfill.
3. The final inspection is to occur upon final grading of the property
Often there will be more than these 3 inspections required. Especially with the installation of
multiple trenches, sand filters, pressurized distribution systems, etc. Thus, the inspecting engineer
is to be contacted at least 24 hours prior to the start of construction. If necessary, a pre -
construction meeting will take place on-site. The inspecting engineer will not coordinate, direct or
control in any way the contractors activities.
The owner shall contract with the contractor to perform the work outlined in these specifications
and plans and in accordance with the attached M.O.A. permit. There will be no contractual
arrangement existing between the contractor and S & S Engineering. S & S Engineering shall be
the owner's representative and will inspect the work as stated above to document the contractors
activities. Final acceptance of the contractors work rests with the owner and the M.O.A.
S & S Engineering shall have no liability to the owner or to others for acts or omissions of the
contractor or any other persons performing work on this project or the failure of the contractor to
carry out the work in accordance with these construction documents. S & S Engineering's
inspecting engineer will not be responsible for the construction means, methods, techniques,
sequence, procedures or the safety precautions incident to this project.
CONTRACTOR/INSTALLER
1_
I
•es+aana`nil6. of r"^.: rii`. fYMO dva
MUNICIPALITY OF ANCHORAGE
Department of Health and Environmental Protection
825 L.,'Street, Anchorage, AK. 9,101
264-4720
Permit # �Aog-9a # # # HANDWRITTEN PERMIT # # #
WELL AND'ON-SITE SEWER PERMIT gg
Applicant: 41-14.si�� L��s>1� 441ne�s Mailing Address:
Location: / Phone Number: 6 9cl_
Legal Description: om76ory1c S Lot Size: /✓'�4L --
Type of Soil Absorption System Is: T'C 1 Ld
Trench: X Drainfield: Seepage Bed: Holding Tank:
Maximum Number of Bedrooms: Soil Rating (sq. ft/br)
The Required Size of the Soil Absorption System Is:
c5 e,7TV U
DEPTH 2 D LENGTH k0 -.e) . GRAVEL DEPTH 5,6' WIDTH 2 s
The length dimension is the length(in feet) of the trenchgor drainfield. The
depth of a trench or pit is the distance between the surface of the ground and
the bottom of the excavation(in feet). There is no set width for trenches.
The gravel depth is the minimum depth of gravel between the outfall pipe and
the bottom of the excavation(in feet).
# # REQUIRED SEPTIC(HOLDING) TANK SIZE _ / ��� GALLONS
Permit applicant has the responsibility to inform this department during the
installation inspections of any wells adjacent to this property and the number
of residences that the well will serve.
# # # TWO M INSPECTIONS ARE REQUIRED # # #
Backfilling of any system without final inspection.and approval by this department
will be subject to prosecution.
Minimum distance between a well and any on-site sewage disposal system is 100 feet
for a private well or 150 to 200 feet from a public well depending upon the type
of public well. Minimum distance from a private well to a private sewer line
is 25 feet and to a community sewer line is 75 feet. Well logs are required
and must be returned to this department within 30 days of the well completion.
Other requirements may apply. Specifications and construction diagrams are
available to insure proper installation.
# # # PERMIT EXPIRES DECEMBER 31, 1 9 3
I certify that:
(1) I am familiar with the requirements for on-site sewers and wells as
set forth by the Municipality of Anchorage.
(2) I will install the system in accordance with codes.
(3) I understand that the on-site sewer system may require enlargement if
the residence is remodeled to include more that 3 bedrooms.
Signed: _ Issued by: 41�
Applicanti/�d �,
,s
Date.
SWP/024(1/81)
o
Date
Gross
Time
SOILS LOG
Depth to
Water
Net
Drop
MUNICIPALITY OF ANCHORAGE
-
DEPARTMENT
OF HEALTH AND ENVIRONMENTAL PROTECTION
❑ PERCOLATION
TEST
825
L. Street, Anchorage, Alaska 99501 264-4720
SOILS LOG — PERCOLATION TEST
PERFORMED FOR:
U /LL�I
/�L ��V�� ` „/eJ' DATE PERFORMED:
j Rvt
�r "� V �`
%✓ % (,4 �a `'°-� "t /� ��/
LEGAL DESCRIPTION:---------1�!%
SLOPE SITE
AN
PTH 0 v -yd
1 L�S Gni
2 r'
3 �� c
4 NFj
6 s� e. '' t i
-/0
8 c� !
10 4k
C O
11 u
s
12
`o
13
14-
15-
16-
17-
18-
19-
20
4151617 18 19 20
COMMENTS
PERFORMED BY:
'
72-008 (6/79)
G Ale
e�ppii lIDD�� AA
i aQ�eos ep�epYoq.L4�
ee 117
�4"'k
F `ca _ oa�c euc
�f�nrl i.. 5hakr
,4•.,, �a. 1r�sa•c ,• ;;
r9F Snune rs V={+QaC �•�t�
9
WAS GROUND WATER n\ S
ENCOUNTERED? L
O
P
IF YES, AT WHAT E i
DEPTH?
Reading
Date
Gross
Time
Net
Time
Depth to
Water
Net
Drop
/ V
ORCOLATION RATE
(minutes/inch)
TEST RUN BETWEEN FT AND
FT
CERTIFI
DA
`
U -N LJ PQ .1 �F--- ��m �.- k --*-i c-:'. F-7
DEPARTMENT OF HEALTH AND'ENVIRONMENTAL PROTECTION
.825 L' STREETv ANCHORAGE, AK 99501
264~472O
PERMIT WO: 850533
DATE ISSUED: 08/22/85
APPLICANT: GEORGE J. JENKINS
ADDRESS: BOX 670141 '
CHUGIAK, AK 99.367
CONTACT PHONE: 688~9662
LEGAL DESCRIP: SUBDIVISION: MONGT8MERY LOT: 4
� SECTION: 16 TOWNSHIP,.- 151\1 RANGE: 1W
�
LOT SIZE: 13200 (SQ.FT. OR ACRES)
BLOCK: NA
I certify that: ^
I. I am familiar with the requirements for on-site sewers and wells as set
forth by the Municipality of Anchorage (MOA) and the State of Alaska.
2. I will install the system in accordance with all MOA codes and regulations,
and in compliance with the design criteria of this permit.
� 3. I will adhere to all MOA and State of' Alaska requirements for the set back
distances from any existing well, wastewater disposal system or public
sewerage system" (--)n this or any adjacent or nearby Iot.
� SIGNE8 DATE: �7~ ~�
APPLICANT:
ISSUED BY
,
DATE:
January 10, 1986
TO: Permit Applicant
P. G. e6X 6c0
t�L/1
A NCwORAG F.l_i�,SKA 79502 -c -65C
(907? 264-4111
DEPARTMENT OF HEALTH & HUMAN SERVICES
Subject: Permit # 850533
Lot 4 Montgomery Subdivision
A permit issued by this Department for an individual well and/or on-site
sewer system has expired as of December 31, 1985.
Permits are issued on a calendar year basis by authority of Municipal
Ordinance. A new permit must be obtained from this Department for any
well and/or on-site sewer system not installed by the expiration date.
If you have drilled the well, a well log needs to be sent to this
Department for documentation of the installation and to close the permit.
If a private engineer inspected the installation of the on-site sewer system
the original as -built inspection report(three part form) must be sent to
this office for review and approval,and for documentation.
If there are any further questions, please call this office at 264-4720.
Sincerely,
Susan E. Oswalt
Program Manager
On-site Services
SEO/ljw
enc: Copy of Permit
'
�
���I F ���. �� ���������
` DEPARTMENT OF HEALTH AND ENVIRONMENTAL PR, OTECTMIN,
,
~ 825 L STREET, ANCHORAGE, AK 99501
` 264~4720
1::*"I���3E MEZ El EH: IfuQ11 EEIF, ;-lc �E-7. 11- U-- IF" l,,E---'F:` 111-11 1�
PERMIT NO:
DATE ISSUED:
�APPLICANT:
�ADDRESSt
CONTACT PHONE:
840970 HAND WRITTEN
11/30/84
C/O,S & S ENG/G ALASKA CUSTOM HOMES
SRB 196X
EAGLE RIVER. AK 99577
694~2979
LEGALDESCRIP: SUBDIVISION: MONTGOMERY LOT: 4
� SECTION: 16 TOWNSHIP: 104 RANGE:' 144 "
LOT SIZE: 13464 (SQ^FT" OR ACRES)
'
BLOCK: NA
I certify that:
1" I am familiar with the requirements fl -or on-site sewers and wells as set
forth by the Municipality of Anchorage (MOA) and the State of Alaska,
2. I will install the�system in accordance with all MOA codes and pegulations,
and in compliance with the design criteria of this permit,
3" I will adhere -Lb all MOA and State of Alaska requirements �or the set back
distances from any existing wastewater disposal system or �ublic
sewerage system on this or any adjace:t op nearby lot.
IF A
LIFT STATION IS
INSTALLED IN
AN AREA BY MOA BUILDING CODES�
�THEN
(1> AN ELECTRICALPERMIT
AND
INSPECTION MUST BE OBTAINED; (2) AS�BUILTS
WILL
NOT BE APPROVED
WITHOUT
AN ELECTRICAL INSPECTION AND (3) THE
ELECTRICAL
WORK MUST
BE DONE
BY A
LICENSED ELECTRICIAN^
`
SIGNED
APpLICANT: C/O S & S ENG/G ALASKA CUSTOMHOMES
ISSUED BY
^
"
DATE:
DATE:
e o ti
POU(`H 6-650
in ic 'npal, c4 i ANCHORAGE, ALASKA 99502-0650
(907) 264-4111
Andra a e TONYNOV.'LES
MA YOP
DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION
Permit #: 840970
January 31, 1985
TO: Permit Applicant
SUBJECT: Lot 4 Montgomery Subdivision
A permit issued by this Department for an individual well
and/or on-site sewer system has expired as of December 31,
1984.
Permits are issued on a calendar year basis by authority
of Municipal Ordinance. A new permit must be obtained from
this Department for any well and/or on-site sewer system not
installed by the expiration date.
If you have drilled the well, a well log needs to be sent
to this Department for documentation of the installation
and to close the permit.
If a private engineer inspected the installation of the
on-site sewer system, the original as -built inspection report
and the yellow copy must be sent to this office for review
and approval, and for documentation.
If there are any further questions, please call this office
at 264-4720.
Sincerely,
Keith E. Bandt, Supe visor
Environmental Engineering Program
KEB/ljw
enc: Copy of Permit
SWP/057
Municipality of Anchorage
Development Services Department
• -�
Building Safety Division ,�
On -Site Water and Wastewater Program `O
4700 Bragaw Street : " 7
P.O. Box 196650
Anchorage. AK 99519-6650
www.muni.orglonsite
(907)343-7904
CERTIFICATE OF ON-SITE SYSTEMS APPROVAL
FOR A SINGLE FAMILY DWELLING
Parcel I.D. 051-193-03 COSA #_ 010303
1. GENERAL INFORMATION Expiration Date: _1/- 1 *3 - O %
Complete legal description Lot 4, MontPomery Subdivision
Location (site address) 22630 Sherman Street Eagle River, AB
Current Property owner( s) Holly Myre Dayphone (907) 301-4224
Mailing address PO Box 243744 Anchorage, AR 99524
Lending agency Day phone
Mailing address
Real Estate Agent _Dean Nelson/Dynamic Prov Day phone (907) 775-6569
. Mailing Address 165 E. Parks Hiphxay, Suite 103 Wasilla, AB 99654
Unless otherwise requested, COSA will be held by DSD for pickup.
2. NUMBER OF BEDROOMS: 2
3. TYPE OF WATER SUPPLY:
Individual Well
Individual Water Storage ❑
Community Class Well ❑
Public Water System ❑
TYPE OF WASTEWATER DISPOSAL:
Individual On-site
Individual Holding tank ❑
Community On-site ❑
Public Sewer ❑
The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of On -Site Systems
Approval (COSA) based only upon the representations given in paragraph 4 by an Independent professional civil
engineer registered in the State of Alaska. Certificates of Onsite Systems Approval are required for the transfer of
title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water
supply system. DSD also issues COSAs upon request to homeowners. Certificates of On -Site Systems Approval
are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued
with new water sample results. (Certificates may be reissued for a period of up to one year with valid water
samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system.
The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work.
4.. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation,
based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application,
shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the information
obtained from the Municipality of Anchorage files and from my investigation and Inspection, the on-site water
supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes,
ordinances, and regulations in effect at the time of installation.
Name of Firm Pinard EnFineerim Phone (907) 357-3647
Address PO Box 871347 WasMa, AK 99687
Engineer's Printed Name Paul E. PJnaal Date
s•
Vo0 Dooaese OeN
5. DSD SIGNATURE
`'e�T©II••e1
dOOoee°•'i
Approved for bedrooms. ••,
Disapproved.
Conditional approval for bedrooms, with the following stipulations:
i .•
nio CITG
� � : WATER AND • �r''
Additional Comments a
Attachments:
COSA Checklist X
Septic System Advisory
Well Flow Advisory
Nitrate Advisory
Arsenic Advisory
Maintenance Agreements
Supplemental Engineers Report
Other
By;/t/ Original Certificate Date: R 1 3— 4 7
(Rev. 11105)
Municipality of Anchorage
' Development Services Department
_ Building Safety Division
'Onsite Water 8 WSstewater Program
4700 Bragaw, Street
h P.O. Box 198650
Anchorage, AK 99519.6650
www.muni.org/onsfte
�1 (907) 34_3,7W4
CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST
Legal Description: _ Lot 4. Montaom y Subdivision Parcel ID: 051-193-03
A WELL DATA
Wen type .Pst H A. B. Or C provide PWSID # _ Well Log (YM) _ R
Date completed _VAk Sanitary seal (YM) Y Wires properly protected (Y/N) Y_
Total depth 314+ ft. Cased to __40 ft. Casing height (above ground) 18 in.
FROM WELL LOG
Date of test NA
Static water level HA
Well production HA
WATER SAMPLE RESULTS:
AT INSPECTION
7/18/07
ft.
156.8 ft.
g.p.m. 4.7 g.p.m.
_Coliform O, colonkW1A0-mL Nitrate 3.02 mg/L Other bacteria 0* 00l0n1es/10GmL -
Arsenio AD mon Date of sample: 7/18/07 Collected by Pinard Engineering `
B. SEPTICIHOLOING TANK DATA *8/1/07 Re—sample by Pinard Engr.
Tank TypelMaterial Septic/HDPE Date Installed 7/1 /04
Tank size 1000 gal. Number of Compartments _2 Cleanouts (Y/N) T
Foundation deanoui (YM) _X Depression over tank (Y/N) JR High water alarm (YM) AA
Date of pumping 12/5/06 Pumper JRe Punpine
C. ABSORPTION FIELD DATA
Date installed -711/04 Son rating (g.p.d./f? or fe/bdrm)1. 2 gpd/1'System type _ Deep Trench
Length _ 25 ft. Width I ft. Gravel below pipe 5 ft.
Total depth _ 7 ft. Eft. absorption area 2.Qftz Monitoring tube _i Depression over field _N
Date of adequacy test 7/ 18/07 Results (Pass/Fail) Paan For 2_ bedrooms
Fluid depth in absorption field before test 0_0 in. Water added gal. New depth3_5 in.
Elapsed rune: 180 min. Final fluid depth 0.0 in. Absorption rate >= 100+
g.p.d.
Arry reiuvenation treatment (past 12 mo.) (YM 6 type) Annn Knnvn
H yes, give date
D. LIFT STATION SA
- Date Installed Size in gallons - Manhole/Aoe,( flN)
'Pump on' level at _ in.
Datum
E. SEPARATION DISTANCES
'Pump off' level at _ in.
Cycles tested
SEPARATION DISTANCES FROM WELL ON LOT TO:
Septic tankAtft station on lot 100'*
Absorption field on lot 1001+
Public sewer main NA
Sewer /septic service line 251+
Animal containment areas NA
High water alarm level at
Meets alarm & circuit requirements?
On adjacent lots 100'+
On adjacent lots 100'+
Public sewer manhole/cleanout NA
Holding tank NA
Manure/animal excrete storage areas NA
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO:
Building foundation 5' Property line 1 ' Absorption field 5 r
r
Water main NA Water service line
101+ Surface water 100 +
Wells on adjacent lots 100' +
SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO:
in.
2' Building foundation 10' Water main NA
Properly line
Water Service line 10' + Surface water 100' + Driveway, parkinglvehicle sloMe 25'
Curtain drain NA Wells on adjacent lots 100' +
F. COMMENTS
in
G. ENGINEER'S CERTIFICATION
I certify that I have determined through field inspections and
review of Municipal records that the above systems are in
conformance with MOA COSH guidelines in effect on this date.
Engineer's Printed Name Paul B Pinard
Date 8/7/07
COSA Fee $
Date of Payment /
Receipt Number 98�Jo3
(Rev. 11/05)
Waiver Fee $
Date of Payment
Receipt Number
00'"000664.04
Ili C'M"d .
'�0-
•.
s
SCS Re0
1073429001
Client Name
Pinard Engineering
Project Name/#
Lot 4 Montgomery
Client Sample ID
Lot 4 Montgomery
Metria
Drinking Water
PWSID
0
Sample Remarks:
All Dates/rimes are Alaska Standard Time
PrintedDate/Time
07/31/2007 14:03
Collected Date rime
07/18/2007 0:05
Received Date/rime
07/18/2007 10:30
Techoical Director
Stephen C. Ede
• Allowable Prep Analysis
Parameter Resdts PQL Units Method Container ID Limits Date Date Init
Metals by ICP/14S
Arsenic ND 5.00 ug/L EP200.8 C (<10) 07/24/07 07/28/07 Mll
f
Waters Department
Total NitratelNitrite-N
Microbiolocv Laboratory
Total Colirorm
3.02
18 OD, No Coli
0.100 mg/L SM204500NO3-F D (<10)
coVl00mL SM209222D A (<1)
07/20/07 IDS
07/18/07 SDP
SCS Reca
1073804001
Client Name
Pinard Engineering
Project Name/N
Lot 4 Montgomery
Client Sample ID
Lot 4 Montgomery
Matrix
Drinking Water
PWSID
0
Sample Remarks:
Paramcter Results
Microbiology Laboratory
Total Coliform 0
All Dales/Times arc Alaska Standard Time
Printed Date/fime
08/07/2007 13:29
Collated Date/time
08/01/2007 21.15
Received Date/time
08/02/2007 10.40
Technical Director
Stephen C. Ede
PQL Units Medad
ooVIOOmL SM209222D
Allowable Prep Analysis
ComainerlD Limits Date Date Init
A (<1) 08/02/07 SDP
JUL 25,2COT 02:OCP AXCUSTCMDLTK
9075614224
ClInr[uoi WTI ed7laa"JI
.VM irowif. PnC£ 81
ins Pmnpby
IO 8M 772415
Esv.4 ILw AY 42377
(»>25%44.4
Setv$ce Agreement
N4mber. 021029
Orddr Wk 29.Mw.20W
M9IMarKYtlHR
Se1Nco UDId DS"Dcc2006 12:0
IidMM9A —�—,
TOCtivj" Osul
PO e0K 2477"
Am UlKn ..
10002
MAL L "
AWnr$00.A1( QM243744
T`—
Not 3u T4r a.• 0
CW7)901-4224
ll w
Kana M 77w Roplat
Nr to
we am 45..
t�D4 OrLiMOmr4RIn
Gw aor
OIO Glee,i 4avy
�,
7t0"N
92070 3keKean swat
wa Ca..w.r"
3e�r 02/21ZOW 10009 —.
ChAlk. AK DD597
flII
ed 6 PAnPad Tank I t:s ramal
(0071 001.4224
Addotiono Loca00.7Co41mr44 Da-V.rr
7
y ._ ... Qoons Plonned: 1000
3rd Mems en AOM . Orem w.W f ■
017 Como by DW
1VLLC DDA%= Gat Actimp �^
Btyft ® Eatk or Mtmo
HJse l
3eMaeas Typ# 4ty Prla s 4 Tim?
3e[tk 3r ,m 15K 1 5135.0C Mo
snQ. ,
OOuhlo hnk: r-,
Puep Lyaem:Wj
flames i t ❑
Dallies OW eT 0
ERMnfICA ACtysl
f t 75.00
4M7rraN TYMI TrrY T-' " 7r iM.t C.rRY Tr.l
tMIKIrICNfr; flb.0e WCC te.4a ft7f 00
A&jd Cl pv
CYMfKM Yra 4 qa l�Nly eYnY71w.� rM TMS F s 4%.()P'47 AOIr r UFW
abrr+Nei T"rI frMs+r i1.P�wwN Drt.
A...rWM Ati lv-!u� OMR ARArr
4� rru Y4Me ArwNNRnN+NmtuM: AN�nrr. tom. Orw 4RR� 4Y MwM Cr1 a' 9-I�M aw tlr P+Ir
ARM a7 DRYS Map .v M LMwr COLI!CTRCga. ab m F. Mer CKw,AR 111 -. .
J7L 7.1,7201 01.7L: JK5—f1PFIK6 9.^,90444821
rs^ 2
page 1
£"d 6w9L5i, QC6) t,n%lptd tie,i(U d£. £0 LO ;L Inf
CCf PINARD ENGINEERING
�y P.O. Box 871347
Wasilla, AK 99687
(907) 357-ENGR (3647)
ADEQUACY TEST
LOCATION: Lot 4, Montgomery Subdivision
APPLICANT: Holly Myra
PO Box 243744
Anchorage, Alaska 99524
SEPTIC TANK TYPE/SD:E: HDPE/1000 Gallons, per MOA Records
ABSORPTION SYSTEM: Deep Trench, per MOA Records
DAILY FLOW:
2 BEDROOMS x 150 GAL/BR - 300 Gallons
TEST DATA
Id�1
JOB NUMBER: 07.186
DATE OF TEST: 7/18107
FIELD STAFF: PJ Pinard
NUMBER OF BEDROOMS: 2
SCUM: 0.0' SLUDGE: Minimal
NEEDS TO BE PUMPED: Yes No XX
CURRENTLY IN USE: Yes No XX
Time
Flow
Rate
Volume
I
Cumulative
Volume
Septic Tank
Septic
Tank
Soil Absorption System
Comments
PM
(GPM)
(GALS)
(LALs)
Liquid Level
'
p Level
Monitor
Tube 1'
a SAS
Level
Monitor
Tube 3'
a SAS
Level
3:05
5.3
-
3.0'
0.0'
Start Flow -Meter 136330
3:20
5.3
so
e0
3.1'
0.1'
0.0'
0.0'
136410
3:35
5.3
8o
160
3.1'
0.0'
0.1'
0.1'
136490
3:50
5.3
80
240
3.1'
0.0'
0.1'
0.0'
136570
4:05
5.3
80
320
3.1'
0.0'
0.2'
0.1'
136650
4:20
5.3
80
400
3.1'
0.0'
0.2'
0.0'
136730
4:35
-
80
480
3.1'
0.0'
0.3'
0.1'
Stop Test - 136810
RECOVERY
Data
Time
ST MT
SAS MT
7/18
6:35
PU
3.0'/-0.1'
0.07-0.3'
'ALL MEASUREMENTS IN FT.
TEST: PASSED XXX FAILED
COMMENTS: There was no measurable liquid In the SAS MT prior to beginning the test. With the addition
01480 gallons to the system (more than the design daily flow). the levet rose to 0.3'. A recovery measurement
taken 2 hours after stopping the flow showed that the level had returned to the stating condition.
Reviewed by: Paul Plnard '�
Date: 7/27/07
LOCATION: Lot 4, Montgomery Subdivision
DRILLER: Unknown
DATE WELL COMPLETED: Unknown
WELL DEPTH: 314'
STATIC WATER LEVEL (top of casing): 158.8'
PINARD ENGINEERING
P.O. Box 871347
Wasilla, AK 99687
(907) 357-ENGR (3647)
WELL FLOW TEST
JOB NUMBER: 07.186
DATE OF TEST: 7118107
FIELD STAFF: PJ Pinard
Time
Elapsed
Time
(Minutes
Static
Water
Level
Flow
Rate
m
Cumulative
Gallons
PUMDed
Remarks
2:45 PM
-
156.8'
5.3
-
IStart Test - Meter 136220
3:00
15
162.4'
5.3
80
136300
3:1530
160.3
5.3
160
136380
3:30
45
159.9'
5.3
240
136460
3:45
60
162.5'
5.3
320
136540
4:00
4:15
75
90
164.0'
158.9'
5.3 1
5.3 1
400
480
136620
136700
4:30
105
162.7'
5.3
560
136780
4:45
120
162.0'
4.7
640
136860
5:00
135
160.5'
4.7
710
136930
5:15
150
162.2'
4.7
780
137000
5:30
165
163.8'
4.7
850
137070
5:45
180
164.2'
4.7
920
137140
6:00
195
163.1'
4.7
990
137210
6:15
210
---T6-4.6'
159.4'
4.7
1060
137280
6:30
6:45
225
240
162.1'
4.7
-
1130
1200
137350
Stop Test 137420
RECOVERY
Average Flow Rate: 5.0 qpm
Comments: DURING THIS TEST, THIS WATER SUPPLY WELL WAS CAPABLE OF
PRODUCING 5.3 GPM. THIS TEST DOES NOT CONSTITUTE A
WARRANTY OR GUARANTEE THAT THE WATER SUPPLY SYSTEM
WILL CONTINUE TO FUNCTION AND PRODUCE AT THIS RATE.
Reviewed by: Paul Pinard -�
Date: 7127107
Municipality of Anchorage
• Development Services Department
Building Safety Division oz
On -Site Water and Wastewater Program `
4700 South Bragaw St. : a
P.O. Box 196650 Anchorage, AK 99519-6650
www.ci.anchorage.ak.us
(907) 343-7904
CERTIFICATE OF HEALTH AUTHORITY APPROVAL
FOR A SINGLE FAMILY DWELLING
Parcell.D. 051-193-03 HAA#
Expiration Date: d
1. GENERAL INFORMATION
Complete legal description Lot 4; Montgomery Subdivision
Location (site address or directions) 22630 Sherman S t . E- F. 9951 -
Current Property ownei(s) Verna Jenkins Day phone 333-3183
Mailing address 13412 H St. Anchorage, AK 99501-4361
Lending agency Day phone
Mailing address
Real Estate Agent Gerry Crowley Day phone 727-7777
Mailing Address
Unless otherwise requested, HAA will be held by DSD for pickup.
2. NUMBER OF BEDROOMS:
3. TYPE OF WATER SUPPLY:
Individual Well
Individual Water Storage ❑
Community Class Well ❑
Public Water System ❑
TYPE OF WASTEWATER DISPOSAL:
Individual On-site
Im
Individual Holding tank
❑
Community On-site
❑
Public Sewer
❑
The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of Health Authority
Approval (HAA) based only upon the representations given in paragraph 4 by an independent professional civil
engineer registered in the State of Alaska. Certificates of Health Authority Approval are required for the transfer of
title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water
supply system. DSD also issues HAAs upon request to homeowners. Certificates of Health Authority Approval are
valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with
new water sample results. (Certificates may be reissued for a period of up to one year with valid water samples.)
Certificates are valid for one year for properties served by Class A or B wells or a public water system. The
Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work.
4. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation,
based on procedures outlined in the Health Authority Approval Guidelines for this application, shows that the on-
site water supply and/or wastewater disposal system is(are) safe, functional and adequate for the number of
bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the
Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or
wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances,
and regulations in effect at the time of installation.
Name of Firm S & S Engineering
Address 17034 N. Eagle River Loop Ste. 204
Phone 694-2979
le River, AK 99577
Engineer's Printed Name Robert C. Cowan Date 7��Jn'1
ROBERT C. COWAN
5. DSD SIGNATURE CE -8801
Approved for _ bedrooms. 1y lei) ....r s.t�;;
Disapproved. iZw`�a
Conditional approval for bedrooms, with the following stipulations:
Attachments:
HAA Checklist X
Septic System Advisory
Well Flow Advisory
Maintenance Agreements
Supplemental Engineer's Report
Other
By:/% � /y Original Certificate Date:
GA1
(Rev. 01102)
Municipality of Anchorage ,E
i«^.. -..e. . .,e..m✓,. -n .w...aF. su x. u. +} 41-8, Development &i ices �Depar Building Safety Division
.k� , .cranchorage.ak us _
t�
PPROVAL CHECKLIST
`�s'+<�"h'YW,&:='�Ya`m+Yy,S.�%ae.'
'Z�I GVl\�2 Parcel ID': ©61 "513 r�3
if A B or C provide Mn ft
Well Lo Y/N A)
)
"etlY.�'dWA's� SYdWl'-' Sv wn `
:..uL..g.� .... .._ .
/VlC Sanitaryseal (Y/N) -
Wves properly protected (Y/N)
�e,X
r 4
_
ft Casetl to ft
Casing height (above'ground) 1 c°i in.
r.:,"`
w;zrsF`7-6
ft, QI
in g:p.m.
� r `f g.p.m.
':`: rw •, � ,.' s6t�'%R'a�:`£"e,.�`.5��°'5�%+'`+rv''.xw�`f`�'u.�°��,a,w."'�L�tit.�."."5��....'�1,'s ,. TM,,,.i z
colonies/100 ml Nitrate mg /I.
Other bacteria colonies/100 ml.
,(
Collected by: / NEC�
a rig
ena TI L {r �j�
��.Date installed 6Z50 6'(
0 o gal. Number of Compartments 2
Cleanouts
)nou ( Depression
ove�ru�tank (Y/N)
High water alarm (Y/N) ^�
�)
Soil rating (g.p.d./ft2 or ft2/bdrm) System type�^�C ff
_ft. Width Z / ft. Gravel below pipe 7 ft.
ft Eff. absorption are6z—�5D ft2 Monitoring tube y Depression over field N
test �� Results (Pass/Farl) _�SS For 2 bedrooms
�oTption ie a ore tes m Water added gal. / New depth_ in.
rnin fluid depth m Absorption rat > g p.d.
treatment (past 12 mo.}'(YIN &type) " If yes, give date
Size in gallons Manhole/Access (Y/N)
in. "Pump off' level at _ in. High water alarm level at in.
Cycles tested Meets alarm & circuit requirements?
A-` On adjacent lots JOE)
On adjacent lots 00
Public sewer manhole/cleanout
Holding tank -,]/,4
,Property line i � Absorption field
fi
Water service line 1 i% Surface water l Co 0 T
r
4- Building foundation Water main `/
r- Surface water j d T Driveway, parking/vehicle storage r'
Nea✓a/ Wells on adjacent lots
y mx
UQ 4
6x, ON
...ai*� �.r`#. Uva.,i:vti "�a! iLflai.. l/SY
micipal records that the above systems are in r L
with MOA HAA guidelines in effect on this date. r' .... '
-. -� C. COWAN / 4, ;
r+ q. Ri70ER'f
r �,.� ce - scot r��
printed Name �Oe3✓ea7,T C �aHeRr� Oa sT •. .•`�� ,.
Date of Payment
3 _ Receipt Number
JUL-08-2004 1311 S&S ENGINEERING carnes aan 1011 0 ."„'
r3c
AS -BUILT
I hereby certify that I have surveyed the following described
propertyeH? 7- r}. •
Anchorage Recording precinct, Alaska, and that the improve.
mens situated thereon are within the property lines and do not
overlap or encroach on the property lymg adjacent thereto, that
no improvements on property lying adjacent thereto encroach
on the premises in question and that there are no roadways,
transmission lines -or other vis*)Ie easements on said property
n„ except as indicated hereon.
Dated at eagle giver, Alaska
this b k
day of
ROBERT C. JOHNSON 7! y
SCALE: Registered Land Surveyor No. 889•LS
`' ::t";,� .:,'•;�j;,,i� 7„ 2..•42' Box 77-D45fi,Eagle River, Alaska 99571
phone (`)[1'!1694-2543
FOTRL P.02
r
SG$- SGS/CT&E ENVIRONMENTAL SERVICES
Drinking Water Analysis Report form1*.t ria
READ INSTRUCTIONS ON REVERSE SIDE BEFORE COLLECTING _.
MUST BE COMPLETED BY WATER SUPPLIER
PUBLIC WATER SYSTEM ID# I /I
(, RIVATE WATER SYSTEM
0 Send Results Send mvolce
Welty Sy lem NamNCOmpOlry Nama
G �NG11��n;G
eemia N.me
CwNa<INBmi
PboroN m er
•�•���••�•��•�
Mailing AWrtas
Fex Number
MaiNnp AtlMesa
Up Co e
Cl1y
Smk
Lp C.ae
SAMPLE COLLECTION:
Fw �s.. ra®emw ewnno
Data:
Memh a.y r..r
Time: I 00e) A
Location: '
;moo
Collector.
f3 Send Results
200 W. POTTER DRIVE
ANCHORAGE, ALASKA 99518
Tel: 907-562-2343
Fax: 907-561-5301
mas7sdq-
[]Send Involve
W.ler SysMlr NameMemperry Name
eemia N.me
Ph.. Number
Fax Ntlmbe.
Mailing AWrtas
city
State
Up Co e
SAMPLE TYPE:
4'Routine ❑ Treated Water
❑ Repeat Sample ❑ Untreated Water
(refer to lab no. )
Special Ptirpose
Transported
to Lab By: ESame as collector Other:
rnleahis. rens wa
TO BE COMPLETED BY LABORATORY
Sample Receiving:
Date: `- 2— fr o� E] Sample over ao hours gid; ❑ RUSH SAMPLE
Time:
/03
'7r? Results may be unreliable
Temp: q,,,,K� ❑ 4e nourwalver Phone #:
Delivery Method; c—l _._._ ��°r Remote Loca' s Fax #:
Received By: ,���IrT
comments:
.........................................................................<...........................,........,................................
Bacteriological Water Analysis Record: [Da
nt to ADEC:
MMO-MUG (PIA) RESULTS: ANC:F:BK JUN —
Analysis Began &1 1-7M Total Coldorm: teTme:
Analyst; 17;0
z0_ E. Coli:
Sent to Client:
Phoned 0 /Faxed
Date/Time:
Spoke with.
Analytical Method:
MEMBRANE FILTER RESULTS:
Direct Count JCJ
C01onies1100m1
I Membrane Filter
Verification:
MMO-MUG (PIA)
r—
*urcxnerm -(LTB:
BGB:
rr�I
L'C!
Satisfactory
r..mcauwm { EC:
❑
Unsatisfactory
TNTC . Toe Num.rom le C..,
Reported By: Date[Time: fps lot os .om.. ean.da
SlnnaWre T
\tpetra\public\DOCUMENT\FORMS\MicrolColi Form 121703.xis
Form # FW- 0053 12/17/03
SGS Ref.#
Client Name
Project Name/#
Client Sample TD
Matrix
Sample Remarks:
1043751001
S & S Engineering
L4, Montgomery S/D
L4, Montgomery S/D
Drinking Water
Laboratory Analysis Report
All Dates/Times. are Alaska Standard Time
Printed Date/Time 06/30/2004 13:56
Collected Date/Time 06/28/2004 12:00
Received Date/Time 06/28/^2004 16:13
Technical Director i S en C. Ede
PQL Units Method Container ID Allowable
Parameter Results Prep Analysis
Limits Due Date blit
Waters Department
Nitrate.N 3.89 0.100
Microbiology Laboratory
Total Coliform
0
mp/L EPA 300.0 B (<=10)
coU100mL SM209222B A (<=1)
06/29/04 JJB
0628/04 DKC
:F rmiro� i SI• "Iru�; LaboratoryDivision 200 West Potter Drive, Anchorage. AK 99518-1605 0907)562-2343 562-2343 f NM 561 5301 w ..sgsenvironmental.com
Member of the SGS Group ISociBtB G4nErale Je Surveillance)