HomeMy WebLinkAboutMOORE LT 43A-1
Municipality of Anchorage Page
DEPARTMENT OF HEALTH AND HUMAN SERVICES
ENVIRONMENTAL SERVICES DIVISION
P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744
On-Site Wastewater Disposal System and/or Well Inspection RePOrt
PermitNumber: ,St, t/ c/100 ~$ PIDNumber: O I ~ /~I ,2 ~D
Name: (~[.]R~' BUR GOYNE Wastewater System: ~New D Upgrade
Address:
3/OD E. ~2 ~, ~cE. ~/~ ABSORPTION FIELD
NO. of Bedrooms: ~Deep Trench ~ Shallow Trench ~ Bed ~ Mound ~ Other
LEGAL DESCRIPTI ON so. Rating:o, ~ GPD/Sq. Ft. Total Depthl2froml original grade:
Lot: Block: Subdivision: Depth to pipe botlom from original grade: Gravel depth beneath pipe
~3 A ~ - Noo~E ~.O ~t. d. o ~t.
Range: Section: Fill added above original grade: Gravel length:
Township: l~N 3~ ~g 0.~ ~t. T~c I'l~ Ft.
Number of lines: O~stance between lines:
WELL: EX1571~ New D Upg.rade Gravel depth: ~. ~ FL 2 I~ Ft.
Classification (Private, A,B,C); Total Deplh: Cased To: Total absorption area: Pipe material: D-
Ft. Ft. 1380 SQ. Ft P~C F-SIC
Driller: Date Drilled: StaticWalerLeve[:F,. Installer~.L,~ ~?'~ Dateinstalle~/
Yield: Pump Sot ~t: I Ca=i~g Height Above Ground: TAN K
GPM ' Ft.I Ft.
SEPARATION DISTANCES ~septic ~ Holding ~ S.T.E.P.
Water ~/oO ~/Oo ~ ~ >/~' LIFT STATION ~.~.
Lot
Line I O~ ] ] I ~ / Size in gallons: Manufacturer:
Foundation ~0 ~ ~ 2 I ~ ~ 0 ' "PLJmp on" level al: "Pump off" level al: High water alarm at:
Curtain Pump Make & Modal I Electrical Inspections performed by:
Drain ~ ~ ~ ~
I
Remarks: ~o~¢ ~ ~ ~ ~e~o~(~ BENCH MARK
~¢~n~ ~e~V~ ~e~ ~ ~ ~Cf Localion and Description:
O~ ~e ore~ Ortq,nally ~/~n~e~ ~r ~ - I Assumed Elevation:
Inspections performed by: FZ4~oP TEEd. 5Vc~ ...... Oates:lst ~/9/ffI ~:*~TH~)~C
Department of Health and Hu~n SErvices approval ~ ~o~o~
Reviewed and approved by: , ...... Date: ,~/o/q[ '~;?~ ......
72-013 (1/91) MOA 25
Permit No. $1~¢' c~ I OO ~ 8 Page ~- of ~
Municipality of Anchorage :
DEPARTMENT OF HEALTH AND HUMAN SERVICES
ENVIRONMENTAL SERVICES DIVISION
P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744
On-Site Wastewater Disposal System and/or Well Inspection Report
Le ~al Description: LOT qsA HooRE 5/D PID No.:
-~ .. E. I,-I.2 ,AvE
30o
IEoO ~.AI.
l y; ?~ '
LoT q3 A
-~IELL
..Fl~attop Technical Services
14530 Echo Street
~[nchorage, Alaska 9951~
ENGINEER S SEAL
72-013 A (2/91) MOA 25
P~rmit No. SM c~/OC)l~'E Page ~
Municipality of Anchorage
DEPARTMENT OF HEALTH AND HUMAN sERviCES
of ~
ENVIRONMENTAL SERVICES DIVISION
P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744
On-Site Wastewater Disposal System and/or Well Inspection Report
Legal Description: L. ur3A HOOI~E' _~]D PID No.: O l~ Icj2~0
JOO
C~O
VERTiCAl.. 5C. AZE': I =5
HoRI'ZoNTd~. NOT TO ~CAI..E
72-013 A (2/91) MOA 25
~ C/O.C/' Borfl ENbS -
M.T..,T,#. #~ SO.q U--~
DRY
Fl tt T ti ca!
14530 Echo Street.
~c.h~rc~e, Alaska 995~6
ENgINEeR'S SEAL
'~ · ·
,~sm~°°o~ ~..~oo~ :~
PERFORMED FOR:
LEGAL DESCRIPTION:
1
2
3 SH
4
5
6
7
8
9
10
11
12
13
14
15,
~6., B.I-I.
17
18
19
20
~attop Technica! Services
14530 Echo Street
Anchorage, Alaska 995]R
Municipality of Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L" Street, Anchorage, Alaska 99502-0650
SOILS LOG m PERCOLATION TEST
CARL ~URGOYNE
LoT ur'~A MOORE
REgblSH
~//~ Township, Range, Section: SEC. 3~ 'T' 12 N R 3 'vv'
SLOPE SITE PLAN
£A'Nb¥ Lo~
51L~ 5ANb
oF (~RAVEL
WAS GROUND WATER
ENCOUNTERED?
POC K~T5
S
YES, AT WHAT
IF
DEPTH? p
E
Deplh lo Waler Alter P/,T;. O,/y~.-
Monitoring? Dole:
Reading Date Gross Net Depth to Net
Time Time ~'f'?/%) Water Drop ~'~ )
PERCOLATION RATE lO (minutes/inch) PERC HOLE DIAMETER
TEST RUN BETWEEN ~.() FTAND 9-,~ FT
COMMENTS ~OIL IN 'THIS 'TE~T ~JOLE I$ 5I~llLtA~ ~0 THAT
PERFORMED BY; FLATTOP T~Ca SVCS I ~ ~ CERTIFY 1HA1 1HI8 TEST WAS PERFORMED IN
aCCORDANOE WITH AlL STATE AND MUNICIPAL GUIDELINES iN EfFEC~ ON THIS DATE, DATE: ~/~
72-008 (Rev. 4/85)
PAGE 1 OF 1
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND HUMAN SERVICES
P.O. BOX 196650, 825 "L" STREET, ROOM 502
ANCHORAGE, ALASKA 99519-6650
ON-SITE WASTEWATER DISPOSAL SYSTEM (UPGRADE) PERMIT
PERMIT NUMBER:SW910088
DESIGN ENGINEER:FLATTOP TECHNICAL SERVICES
OWNER NAME:BURGOYNE CURT L &
OWNER ADDRESS:3100 E 142ND AVE
ANCHORAGE, AK 99516
PARCEL ID:01819240
DATE ISSUED: 5/29/91
EXPIRATION DATE: 5/29/92
LEGAL DESCRIPTION: MOORE LT 43A
SEC. 33, T12N, R3W, SM
LOT SIZE: 40708 (SQ. FT.)
NUMBER OF BEDROOMS: 5 THIS PERMIT: 5
THIS PERMIT IS FOR THE CONTRUCTION OF:
DISPOSAL FIELD SYSTEM
ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH:
1. THE ATTACHED APPROVED DESIGN.
2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS
15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL
REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (iSAAC80).
3. THE FOLLOWING SPECIAL PROVISIONS.
SPECIAL PROVISIONS:
RECEIVED BY: ~_
DATE:
,~'~",~?';;,;".'"~;~ ' ."~" ...... '~'4~",',"?x,~;'.?;>~. ;'~;':~'?A;',';; ~";'"" ,:;:'" ;,':":~'"~:'"~'~"t""9~?'-%.~ ~
~I~1~ & ~RO~M~T~L ~RI~ · E~¥ ~O~S~R¥~ & ~L¥~
TH3EODORE F. MOORE, P.E. 14530 ECHO ST.
PH: (907) 345-1355lv:''ayo", 1991 ANCHORAGE, ALASKA 99516
M.O.A. DHHS
P.O. Box 19-6650
Anchorage, AK 99519
Dear Sirs:
By means of this letter we are requesting issuance of a permit for the installation of a 5 bedroom
wastewater disposal system to serve the Burgoyne residence on Lot 43A of Moore S/D, located at 3100
East 142nd Ave. Soils logs, a site plan and design drawings are enclosed. Groundwater monitoring
conducted this spring demonstrated that there is no groundwater to 16 feet. The measured percolation rate
of 14 minutes per inch applies to all of the material below 6.5 feet. The system is conservatively designed
utilizing an application rate of 0.6 gpd/sq, ft. = 250 square feet per bedroom. Thus a 5 bedroom
residence requires 5 x 250 = 1250 sq. ft. of absorption area which is accomplished by three 38 foot long
soil absorption trenches with 5.5 feet of sewer gravel beneath the distribution pipes as designed, with a
total of 1254 square feet of sidewall area. The site plan indicates a proposed site for a replacement system
just north of the proposed system. The test hole locations were chosen to be representative of soil
conditions in both the original and replacement sites.
The site plan indicates the locations of neighboring wells and septic systems and other relevant features
within 200 feet of the proposed facilities. The topography of the lot is generally level with a low rise in the
vicinity of the proposed replacement system and a gentle 5% slope to the south in the vicinity of the
proposed construction site.
The proposed construction will eliminate an existing separation distance problem and a failing septic
system. There will be no measurable impacts to wells or wastewater systems serving adjacent properties,
nor will it have any impact on reserved space/surface and subsurface, or on drainage.
Please give me a call if you have any questions.
Sincerely,
Ted Moore, P.E.
'LOT 2.1
i 100t "FO vdE/-L ' I
E. i'+2 AVE,
L
E
Flattop Technfcal Services
14530 Echo Street
Anchozage, ]:~.lo:s]ccz 995]6
RECEIVED
Mun~c,pah~y mt Anchorage
Dept. Health & Human ServicerS/
LoT L~3 A MOORE S/D
.SEPTIC SYSTEM REPLACEMEI'
S~TF PLAN
SCALE 1"
DATE: Ur/qf
NOTE: THIS IS Nc
A SuRVEYEb pL,
ALL LOCATIONS
AR~
'LoT
LIA
'fo
L2A
BRA~OL
F-
LO-r 2~
E, l Ur2 AVE,
oN LOT ~.~.,
300t
LOT t.k3 A
,.T. iC~t i ,
Lo'f
1
I
BousE
I,¢ EL L
Flattop Technical Services
14530 Echo Street
Anchorage, Alaska 99516
% %'~.,~, · ...... _ ~:~
LoT u~3 A MOORE s/D
SEPTIC S/STEM REPLACEMEI
SITE PLAN
SCALE: 1%-5o,
DATE: q-/ql
~)w~l BY: ~.
NOTE: THIS I$ N~
A SuRVE¥ffb pL
/~LL LOC AT~ONS
AR~ APPP-oxtH/
Ar-,
NoN- PERI=
PLAN
· To'('/~ ~'
C~RAVEL
bE, PT H
F I LI',ER 'F/:IBR I. C
~'" J S',,5' ~eP'r~ ~ ,,,
~!attop Technical Servic~
14530 Echo Street
J~ - /~ Anchorage, Alaska 995:
LOT ~-3A MOORE s/D
SOIL ABSORPTION TRENCH
PLA N ~' CRo5%- $[c'T ion
SCALE
DATE'
PERFORMED FOR:
LEGAL DESCRIPTION:
3
4
7
g
10
11
12
13
14,
15-
16
17
18
19
20
Flattop Technical .~ervices
14530 Echo Street
Anchoracm, Alaskc~ 99518
Munlclp~llly of Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L" Street, Anchorage, Alaska 99502-0650
SOILS LOG -- PERCOLATION TEST
CARL 15UR GOYNE
LOT NF.3A
M00I~E' ~//~ Township, Range, Section: SEC 33., T 12
SLOPE SITE PLAN
GRAVEL FILL
SILTy
COMMENTS PP-Rk. 'TE~'F
5LI.roHTL¥ SILTY gANI)
.SOME COBBLES
LOOSE, DRY
WAS GROUND WATER
ENCOUNTERED?
Depth to Water After
Monitoring? DR'/' Oale:
IF YES, AT WHAT
5~[ MO~E DEPTH?
COHESIVE tN
THIS 'Zone
Reading Date Gross
ST/i
~t
Time
2: ~E
3:10:oo
Net ·
T!me (~
3: qo: 30 15"
Net
Crop
PERCOLATION RATE I t~ (minutes/inch) PERC HOLE DIAMETER ,
TEST RUN BETWEEN ,~.~'. FTAND '~.O FT
V/~Lib BC-'TN/K~ S.S ' A~.I'O 16 '
PERFOnMEDa¥: FLATTOP T'.=Ct-I..c,V'e_.~ ,...,~.~X')/-/.r...<_~
OERIlF Y 1 HA'I '1 HIS TEST WAS PEFIFORMED iN
AOOORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINE8 IN EFFECT ON THIS DATE. DATE:
72-008 (Rev, 4/8~)
PERFORMED FOR:
LEGAL DESCRIPTION:
1 5~
2
3 SM
4
5
6
7
51,4
8
9
10
11
12
13-
14
15
~ B.~.
17
18
19
20-
Flattop Techn~ca! Services
14530 Echo Street
Anchorage, Alaskc~ 99516
Munlclpallly o( Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L" Street, Anchorage, Alaska 99502-0650
SOILS LOG -- PERCOLATION TEST
CARL ~R~OYNE
LO"[ %3 A MOORE' ~/~ Township, Range, Section: SEC 33 j T 12 N., R 3 ~
SLOPE
~,TH ROOTS'}
6RA~ SILTY ~ANb
DRy~ HAN~ COBBLE5
GRAY 5Li&HTL"I SILTY
5~Nb, DR~
$OFTEP~ DIGGING
WAS GROUND WATER
ENCOUNTERED?
S
L
IF YES, AT WHAT O
DEPTH;) p
E
SITE PLAN
s~ ,4 ,'A b
Del)Ih to Water Aller ~_.,
Reading Date Gross Net Depth to Net
Time Time Water ' Drop
PERCOLATION RATE __ (minutes/inch) PERC HOLE DIAMETER
TEST RUN BETWEEN FT AND __ FT
COMMENTS PERK ~/~TE ~E/~Su12E-b FoR; T.~ ~l APPLIE~ TO
~HIS T~ST HoLE ~L5o.
P~nrOnU~DDV: FLATTOP TECH, ~VC~ m ~, ~
CEIllltY1HA1 1HIS TEST WAS PERFORMED iN
ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES m~ ~F~OT ON THIS DATE. DATE:.,
72-008 (Rev. 4/85)
PERFORMED FOR:
LEGAL DESCRIPTION:
PT
I
2
4-
5
6
9
lO
11
12
13-
14
15
~6 B.~t.
~7
~8
Flattop Technical Services
14530 Echo Street
Anchorage, Alaska 9951~
Municipality of Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L" Street, Anchorage, Alaska 99502-0650
SOILS LOG -- PERCOLATION TEST
CARL BURGOYNE
LoT UrhA MOORE
~/~ Township, Range, Section: SEC B3 T [2
SLOPE SITE PLAN
R£DblSH 5AND~ LoAM
P0c K~T5 oF
WAS GROUND WATER 5'l'/)Nb PtP£S
ENCOUNTERED?
S
L
IF YES, AT WHAT O
DEPTH? p
E
Depth to Water Alter
Monitoring? Oate:
Reading Date Gross Net Depth to, Net
Time Time Water Drop
PERCOLATION RATE __
(minutes/inch) PERC HOLE DIAMETER
TEST RUN BETWEEN __ FTAND __FT
COMMENTS ~OI/ tN. -'rJJrl5 'I"E~T ~OL~' I<~ 51MiLiAI~ --re THAT FovNb iN T.H.'.~ ffl · '~2 .
.E.~O.MEDa¥: FLATTOP T~ECf~. _qVC..~ , ~--.~.~r~.,..,..~ CEm'"V~HA~H,STES~WAS~ERFORMED~N
ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE:
72-008 (Rev. 4/85}
Flattop Technical Services
14530' Echo Street, Anchorage, AK 99516
Phone (907) 345-1355
Lot 43A Moore S/D
3100 East 142nd Avenue
Wastewater disposal system installation
Specifications
1.0 General:
1.1 The scope of the project includes abandonment of the existing septic'system and const~:uction of a
new 5 bedroom wastewater disposal system consisting of a 1500 gallon septic tank followed bY three
parallel soil absorption trenches each 38 feet long with 6 feet of sewer gravel.
1.2 Construction shall be as depicted on the approved site plan and design drawings. Minor
deviations from these drawings may be allowed or required by the engineer conducting the inspections.
All construction procedures and material specifications shall conform with Municipal and State
requirements.
1.3 All separation distances shall be in conformance with Municipal requirements, unless specifically
waived.
1.4 The contractor shall be responsible to obtain any necessary utility locates, and to work around any
buried utilities.
2.0 Septic Tank:
2.1 The septic tank shall shall have 2 compartments and a capacity of 1500 gallons and be Municipally
approved. The tank shall be set level on undisturbed soil. Each compartment shall be equipped with a
watertight manhole cover and a 4" cleanout. If the tank is buried less than 4 feet, it shall be insulated with
2 inches of approved burial type, rigid insulation.
2.2 All pipe connections to the tank shall be equipped with waterproof mechanical couplings. The
waste line from the residence to the septic tank shall have a minimum slope of !/4'" per foot, and the waste
line between the tank and the soil absorption system shall have a minimum slope of 1/8" per foot. A
cleanout shall be installed within 5 feet of the building foundation, and a double cleanout shall be installed
within 5 feet downstream of the septic tank.
2.3 The existing septic tank is to be properly abandoned by pumping, crashing and burying on site.
3.0 Soil absorption system:
3.1 The soil absorption system shall be constructed by excavating three 38' long trenches to a total
depth of 12 feet.
3.2 The bottom of the trenches shall be level. Any compacted or smeared surfaces shall be raked to
allow proper infiltration.
3.3 A total of 6 feet of sewer gravel shall be placed in the trenches. The sewer gravel shall be 0.5" -
2.5" screened gravel, with less than 3% passing the #200 sieve.
3.4 The perforated distribution pipes shall be laid level with the bottom of the pipes being 5.5 feet
above the bottom of the sewer gravel. Particular care shall be taken to ensure that the distribution pipes
and the non-perforated manifold are all laid at the same elevation to encourage even distribution of effluent
between the three trenches.
3.5 Monitor tubes and cleanout pipes shall be of 4" diameter and installed in the locations shown on
the design drawings. The portion of the monitor tube extending through the sewer gravel shall be
perforated.
3.6 Approved filter fabric shall be placed over the entire top surface of the sewer gravel.
Approximately 6 feet of soil cover is to be placed over the filter fabric. The top surface of the cover ·
material shall be raised a minimum of 6 inches higher than the surrounding terrain to allow for subsequent
settlement, and shall be graded to smooth contours.
3.7 The existing soil absorption trench is to be abandoned in place with the standpipes removed.
4.0 Inspections:
4.1 A total of 4 engineering inspections will be required during the course of the project: (1) initial
stakeout with the contractor to establish the location of the system and to discuss the plans, specifications
and construction procedures, (2) after the native material has been excavated to expose the infiltrative
surface to ensure that it is level and at the right elevation, and conforms with the soil test information, (3)
after the sewer gravel is in place and the distribution pipes have been laid and connected up to.the septic
tank, but prior to placement of the filter fabric, and (4) after final backfill and grading is Complete.. The
septic tank requires one inspection after it is set level and the piping connected, but prior to backfill. This
inspection may be incorporated with any of the above inspections.
4.2 The installer shall coordinate the timing of the inspections with the engineer sufficiently far in
advance to ensure the availability of the engineer.
Flatto~ Technical Services
14530 Echo Street
Anchorage, Alaska 99516
./
Well Owner
FvI-W DRILLING, Inc.
P.O. Box 10-378 * 10300 Old Seward Highway
(907) 349-8535
ANCHORAGE, ALASKA 99511
DRILLING LOG
Use of Well Domastic
/
Location (address of: Tow~nship, Range, Section, if known; or distance main road
Lot 43-B l%ore Subdivision
Size of casing_
Static water level
Screen (
);
Describe screen or perforation None
Well pumping test at 10 gallons per (~
of drawdown from static level.
Date of completion Aug:hist 2; 1983
.Depth of Hole 130 feet Cased to 129 feet
90 ft. (~ (below) land surface. Finish of well (check one) open end ( xx );
Perforated ( ).
(m~nute) for i hours with 100% ~
WELL LOG
Depth in feet from
ground surface Give details of formations penetrated, size of material, color and hardness
0 TO__ 2 Casing sticlcao
2 TO. 30
30 TO 80
80 TO~
___]J_D_T O 127
127 .TO 130
.TO
.TO
.TO.
TO
TO
TO
Brcr~n clay and ~ravel
Brown clay and graval_(dz~Ap)
(Pra~v silty grava_]
Gray h~rd
Waterbearing gravel
NWWA Cern, iliad Conh',~cLu,e
Certificate No's. 814 & 973
1- CUSTOMER
~_,~. MUNICIPALITY OF ANCHORAGE ~
· DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION
ENVIRONMENTAL ENGINEERING DIVISION
825 L Street - Anchorage, Alaska 99501 Telephone 264-4720
ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
MAiLI-I~b-ADDRESS- ~ ~ / ~/
LEGAL ~ESCRIPT~ON
LOCATION ~~[ Well Absorption area Dw;lling , PERMIT NO.
Material ~ ~ No. of compar~ents
~ Z Manufacturer
~ k Inside length Width Liquid depth
Liq. c~t~ in gallons IF HOME.DE:
~M~hufa~turor '~~
" Foundation Nearest Iot~oline, PERMIT N~
~=.~ DISTANCE TO: Well/¢~, ~ Distance between~2~
~ No. oflines, Lengthofeachline_~_,, Totallengthoflines~.~ Trenchwid,~. inches
~k Materi'al beneath tile Total effective absorption area
Top
of
tile
to
finish
grade~
Type of crib ~~ ~on Nearest lot line
' DISTANCE TO:
~ Clas Depth Driller Distance to lot line PERMIT NO.
m , Building foundation Sewer line Septic tank Absorption area(s)
~ DISTANCE TO:
PIPE MATERIALS ~
SOl L TEST RATING ~
,
INSTALLER ~
REMARKS /
-013 (Rev. 3/78)
F ERH I T NO.
FIF'F'L T CRNT
LOCFt-F T ON
LEGRL.
DEPFtRTMENT O~:-*'HERLTH FIN[::, ENV)~RONMENTFIL Fh~..OTECTION
825 '" L.
264-~.472F'~
FINE:,F.:EI.,~ L _ r EF..
[:,ERRHOUN ,?., SRE: I NE
L. 4.2: S2.::~: I]..-=N F.'.]:N
7E90 [:,EE:RRR -tf;=..:OE;
LOT ~;IZE
7 6'76 }i:
FIRE FEET
T'Y'F'E OF SOIL RBSOF.:E:TION _T:.TEH I TF.:ENCH
HR~-,;~f'IlJH ~&IHBEF.: OF E,'E[)ROOHS = 2; SOZL 'F.:RT~N6 ':ST.~ FT,.'"BR::'=:
THE REL=.!I_I~.RED SZZE i:IF THE SOIL RE:SORF'TIL3N S'¢STEH ~S:
[:. E F" qF' b-~ ==
THE LENGTH DIHEN'::.;~ON 1'S THE LENGTH ".:ZN FEET) OF 'THE TRENCH OR DRR:(NFZE[..I.".:'.
THE DEPTH OF' FI TRENCH OR PET Z~; THE [:,TSTRNCE BETI.,.IEEN THE SURFRCE OF THE
GROUND FIND THE BOTTOH OF THE EXCRVFIT]ON ,::ZN FEET::'.
'THERE ~S NO SET N~E:,'f'H FOR. TRENZ:HES:;.
THE GRF]VEL DEF'TH ZS THE H]:N.T. HLtH DEFq-FI OF ISRFIVEL BETNEEN THE OI_ITFFILL. P~F'E
RND THE BOTTOH OF THE EXC:FtVFFf'ION ,::~N FEET).
F'EF.:HIT FIF'F'LICRN'f' HRS THE RE'SPONSIE:IL. ZT'¢ TO INFOF.'.F'I THIS [:,EF'FIRI"HENT [,I. 1~;']'[.~ THE
ZNSTRLLRTZON ~NSPEC"I'~ONS OF FIN'¢ NELLS RD.ZRCENT TO TI-lES PRZF'ERT'T' R[.,IE:, THE
NUt,IBER OF' RES~E:,ENCES THRT THE 1.4ELL NZLL SERVE.
BRCKFZLLZNG OF RNa' 5'¢5TE1'1 NZTHOUT F'ZNRL ]:NSF'ECTZON FIND RF'PROVRL.
DEPRRTHENT 14ZLL BE SUB.]ECT TO PROSECLFZON.
f,IZNiHUH DISTI~NCE BE'f'NEEN R FJEL_L FIND RN'Y' ON-SITE 5ENRGE DISPOSRL S'T'STEfq FEET FOR R F'F:I',,,'F~]"E 14ELL.~ OR
TO 2¢0 FEET FR3H R F'UE:L. IC NELL. [:,EF'ENDING UF'ON THE T'¢F'E OF P_EI_IC I.,.IELL..
OTHEF: REQUIREr'lENTS HR'¢ FIF'F'L'¢. SPECIF'ICRTIONS RND CONSTRUCTION [:,IFIGRI~H5 RRE
R'¢R]:LRBLE TO INSURE PROPER INSTFII_LRTION.
I CER'f'IF'¢ 7'HAT
· 1.!_: I Rf"l F'FIHIL. IFII~: NITH TFIE F.:EL=.!UIF.:Er,'IENTS FOR ON-SITE SEI.,.tERS FIND NELLS 8S SET
FCRTH E:'¢ THE f,tUNICIF'FtLIT'~' OF FiNC:HOF..:RGE.
2: I NILL INSTFILL ]"FIE :,~:,rErl IN RCCOR[:,FINCE NI]'H THE CO[;,EE;.
2:: I UN[:,ERSTFIN[:, TNRT THE ON-SITE SENER S'T'S-FEf'I HFI'~' RE'::.~IJ]F.:E ENLRRGEHENT IF' THE
F.:ESIE:,ENC:E IL5 F.:Ef,IODELED T~:,E HOF.'.F THFff.,I 2: E:EDROOf'IS.
'.E; I ,:iN E[::,: ~ ~ ~,.~ ............................
..:....m .....
'.[ SSUED E 'Y' I I FE
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION
Pouch 6-650, Anchorage, Alaska 99502 276-222lr
SOILS LOG- PERCOLATION TEST
SOILS LOG
PERCOLATION
TEST
/
LEGAL DESCR,PT,ON: L,~---4 g ) ;>~,~; ss.r ~ t~
8
9
10
11
12
13
14
15
16
17
18
19
20
SLOPE
WAS GROUND WATER
ENCOUNTERED:
IF YES, AT WHAT
DEPTH?
SITE PLAN
14e+
Gross Net Depth to Net
Reading Date Time Time Water Drop
PERCOLATION RATE 1'7 minutes/inch)
TEST RUN BETWEEN 4-~ ~ FT AND ',~-~' FT
72-008 (7/76)
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION
DIVISION OF ENVIRONIViENTAL HEALTH
CERTIFICATE OF INSPECTION FOR HEALTH AUTHORITY APPROVAL
OF ON-SITE SEWER AND WATER FACILITY
264-4720
Application Date
GENERAL INFORMATION
(a) Legal Desccption (include lot, block, subdivision, section, township, range)
Locati~j~s or d.j.ctions)
(b) Applicant Name _~/'U ,~"/~'~--C¢_~ Telephone: Home3~
Applicant Address / ~/ ~'~ ~~-)
(c) Applicant is (check one): Lending Institution ~; Owner/builder; Buyer ~; OtherD (explain);
(d)
(e) Real Estate Company and Agent
Address
Telephone
(f)
Mail the HAA to the following address:
TYPE OF RESIDENCE
Single-Family ~( Multi-Family
Number of Bedrooms
Other
WATER SUPPLY
individual Well~' Community [] Public []
Note: If community well system, must have written confirmation from the State Department of Environmental Conservation
attesting to the legality and status. ..~ '
%r
*' ~i! .,
4. SEWAGE DISPOSAL
Onsite Public [] Community [] Holding Tank []
Note: If community well system, must have written confirmation from the State Department of Environmental Conservation
attesting to the legality and status.
Page 1 of 2 72-025 (11/84)
ENGINEERING FIRM PROVII~ItWG INSPECTIONS, TESTS, FILE SEARCH, b1~:rA AND INFORMATION · t
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health
Authority Approval shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained
from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or
wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on
the date of this inspection·
Name of Firm ~
Address SJJ B 1~](
Date F-..~kGLE RIVER, AK 99577
Telephone
DHEP APPROVAL
Approved for /' ~
Approved ~%------'~
Terms of Conditional Approval
,~ \'~.i/:) ,
CA U TI O N
The Muncipality of Anchorage Department of Health and Environmental Protection (DHEP) issues Health Authority
Approval certificates based solely upon the representahons given in paragraph 5 above by an independent professional
engineer registered in the State of Alaska. The DHEP does this as a courtesy to purchasers of homes and their lending
institutions in order to satisfy certain federal and state requirements. Employees of DHEP do not conduct inspections or
analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the
professional engineer's work.
Page 2 of 2
72-025 (11/84)
MUNICIPALITY OF ANCHORAGE (MOA)
HEALTH AUTHORITY APPROVAL (HAA)
CHECKLIST- FEBRUARY 1984
264-4720
Legal Description: ~
M~JNiCiPALITY OF
DEPT. OF HE/,LTH &
I]NVIRONMENTAL PF:OTECTION
2 1986
WELL DATA
Well Classification
Well Log Present (Y/~i)
Total Depth ~¢~o
Static Water Level
~. [¢~' If A, B, C, D.E.C. Approved (Y/N)
Date Completed ~F~¢[~ J~'il~-~ Yield
Cased to J~ i'1¢ Depth of Grouting ~"
~¢~.0~ Pump Set At O[/--
Casing Height Above Ground ['7~ Sanitary Seal on Casing~N)
Electrical Wiring in Conduit (Y~ ~ Depression Around Wellhead (Y/~])
Separation Distances from Well:
To Septic/JCefdf~g Tank on Lot [ ¢:~ ; On Adjoining Lots
To Nearest Edge of Absorption Field on Lot ~ c2~27..~ ; On Adjoining Lots
Nearest Public Sewer Line ~.~ ~r--]~ To Nearest Public Sewer
To
Cleanout/Manhole ~"','/~' To Nearest Sewer Service Line on Lot
Water Sample Collected by
Water Sample Test Results _~'.~,r'~ ¢~, ~-~'~,~-~
Comments ~..~ ~=~"~..- ,..J t. ~ '~-~i¢~..~ ~--~ G~[:~ J¢'
B. SEPTIC/14~L-BtNC=~-TANK DATA
Date Installed 1'~'-'2-""7'¢~ Size t ~;;~c~ N6. of Compartments 7..-
Standpipes~/N) Air-tight Caps'/N) Foundation Cleanout (Y~
Depression over Tank (Ye _ , Date Last Pumped ~:~' ~ ' ~
Pumping/Maintenance Contract on File (Y/N) ~j ~/~ ; for /
/~ Temporary Holding Tank Permit (Y/N)
Holding Tank High-Water Alarm (Y/N)
Separation Distances from Septic/H,P.~.g Tank:
To Water-Supply Well
To Property Line ~ ~'~'
To Water Main/Service Line
Course
To Building Foundation
To Disposal Field
To Stream, Pond, Lake, or Major Drainage
Comments
Page I of 2
72-026(11/84}
C. ABSORPTION FIELD DATA
Soils Rating in Absorption Strata
Date Installed __ I..J¢~... ~ '-~
Width of Field "~ ~
'~""/-"'~ ~~ Type of System Design
Length of Field
Depth of Field ~ "2.,-
Gravel Bed Thickness ~:'
Square Feet of Absorption Area
Depression over Field (Y~
Results of Last Adequacy Test
Separation Distance from Absorption Field:
To Water-Supply Well
To Building Foundation '¢~ ~:>~
Lot
Standpipes Present
Date of Last Adequacy Test
To Property Line
To Existing or Abandoned System on
I
To Water Main/Service Line ~ ¢' ~
To Stream/Pond/Lake/or Major Drainage Course
To Driveway, Parking Area, or Vehicle Storage Area
Comments
; On Adjoining Lots
To Cut[lank (if present)
D, LIFT STATION
Date Installed
Size in Gallons
"Pump On" Level at
High Water Alarm Level at
Tested for
Electrical Codes (Y/N)
Dimensions
Manhole/Access (Y/N)
"Pump Off" Level at
Vent (Y/N)
Pumping Cycles during Adequacy Test. Meets MOA
Comments
** Check Permitted Bedroom Rating Against HAA Request **
I certify that I have checked, verified, or conformed to all MOA and t~AA guidelines in effect on the date of this inspection.
S & S FNG!NI~FD_IN6 Date ~,/~,, ...~/~
Signed
CompanySRi~ 196X MOA No. ~'~'/O...?_~ ....
EAGLI~ RIVER, AK 99577 9'0~
Receipt No.
Date of Payment ~' '~..~1-~[,,,
Amount: $
Page 2 of 2
72-026 (11/84)
APPLICANT FILLS OUT UPPER HAl. '- ONLY
· ~Pr~p~,?ty ~ . (~ Phone
Address Zip Code
Lending Institution & V ~ ~ rq Phone
Realty CO, & Agent ~/~' CO ~C:~ Phone
Address Zip Code
St~et Locati~ ~ ~__-- Y~
Type of Resi~nce
~ Single Family
~ Multiple Family No. of Bedroo~
~ Other
Water Supply
~ A~ACH WELL LOG. A w~J log is required for all wells drilled since June 1975.
Individual :~ ~.n .~
Communityx~'~'~.- For wel~s drilled prior to that date, give well depth (attach log if available).
~ Public Utility
Sewer Disposal
individual Year Individual installed: tj~::
~ Public Utility When Connected to Public Utility:
~ Holding Tank
NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH RE~EST BEFORE ~OCESSING CAN BE INITIATED.
Time Time Time
Time --
Date Date Date Date
Inspector Insp~tor Insp~tor Insp~tor ,
0 ~ ' . ~. ~ '"~o~c~o~
( ) APPROVED BEDROOMS 'CONDITIONS OF APPROVAL
( ~:DISAPPROVED
( ) CONDITIONAL APPROVAL*
DATE J ~
SoiJs Rating Date ~wer Installed Well To Absorption Area JO~ ~ WelJ Log Received
Well to Tank ~ Septio T~k Size
12.023 (3182)
October
Joseph Co -ioore
SiLA Box 246-[~
Anc~]orage, AK 9950'7
Sub3ect: Lout 43A, ?ioore Subdivision
ApDrovai for the individual se:;~er and water ..... ''''' ~
be granted until tile following items have been completed:
· VlOmat_oll
E~,~posed electrical wires to the ~,,,el! head are in ~ ' ~ ~'i~
of the ~unicipality o~ Anchorage codes and must be ~ncased
in conduit,
We have no record of the on-site permit nor as-builts for
the sewer system. Please submit your copies or check the
above legal in case they are file(] under another legal
description o
Please notify this Department for a reinspectio~ when ~'~
noted
d~oc~.~,.)anclc~ l~ave been corrected If there are any
~urther questions~ please call this of[ice at 264-4720.
oincerely~
(mgo/ej/~2
Cory Willis,
Acting Sewer & ~ater
Pro~jram ~-~aaage r
_uepartmenj; If} E.nv ~ro~en t~'~ug; i tv
Street, .An~t~a~e~o~[ 9~503 274-4561
t Ih . I
ime of Inspection
-- ~ Date of inspection ~
REQUEST FOR APPROVAL OF
1. Approv, equested by:
Mailing A. dress:,
NDIVIDUAL SEWER & WATER FACILITIES
1/, ih.
2. Property Owner: Robert D. & Cheryl A. Bush
Phone:
Phone:~
Mailing Address: Star Route A Box 246-B, Anchorage 99507
3. Legal Description: Lot 43 NW~ Sectio~!$~ T12N R3W S.M.
?. Location: Brandl and Eas~ 142nd
349-2408
Type of facility to be inspected Single Family
We]] Data: Indivi~6~
A. Type
C, Construction
7. Sewage Disposal System:
A. Installed
¢. Septic Tank:
D. Seepage Pit:
E. Disposal Field:
Distances:
1. Size
1. Absorption Are~
Total length of lines
A. Well to: Septic tank
(Rabbit Creek Small
Tracts)
, Sewer Lines
C. Absorption area to nearest lot line
EQ-034 (1/74) Page 1 of two pages
B. Foundation to septic tank
Nearest lot line
, Absorption area
, Other contamination
, Absorption area
No. of bedrooms 2
B. Depth 90' ~
D. Bacterial Analysis~
On-site system.
B. Installer
2. Manufacturer
2, Material
Page 2 of two pages - Re~,.~.~t for Approval of Individual .~ 'r & Water Facilities
Legal Descrip,tion T,ot 43 .lXlW~ Sect±on 33 T12txl R31~ $.M. (Rabbit Creek 8mall ri'tact
Comments
Approve, Disapproved . ;~:' .... ..
1 Valid for one year
f~om~da,te §igned
nchorage Ar~a Borough, Department of Environmental Quality
DIAGRAM OF SYSTEM
certify that the information contained in this request for approval to be a true and
accurate representation of the subject sewer and water facilities and these facilities
are operating satisfactorily.
SIGNED Date
EQ-034 (1/74)
GREATER ANCHORAGE AREA BOROUGH
Department of Environmental Quality
333D "C" St., Anchorage, Alaska 99503 - 274-4561
REQUEST FOR APPROVAL OF
INDIVIDUAL SEWER & WATER FACILITIES
1. Type of Inspection: CMRO VA
2. Prope'rty Owner: Bush, Rober± D. & Cher¥ A.
Mailing Address: SRA Box 246-B Anchorage, Ak
99507
3. Name of Buyer:
Mailing Address:
4. Name of Lending Institution:
Mailing Address:
5. Name of Realtor or Agent:
Mailing Address:
FHA CONV
Day Phone 349-2408
Das Phone
Phone
Doris Timperley--Dyqamic RealTy, Inc.
3380 C St Suite 104
Anchorage, Alaska 99505
Phone 279-76 .
Legal Description: Lot 43, NW¼, Sec 33, TI2N, R3W, S.M.
(Rabbit Creek Small Tracts)
Location: Brandl & E. 142nd. St.
right
Go I/3 mile up DeArmoun, Turn ~ on Sabine, TaKe next left, look for ~ sign
on righf siae of sTreeT.
Type of Facility to be inspected: SFR No. Bdrms. 2
Nater Supply
Type of Supply: Public Utility Individual xx
If Individual, number of dwellings presently served I
If Individual, depth of well 90 Ft.
Sewage Disposal'System
Type .of S~stem: Public Utility
If Indiv'idual, date of installation
Individual (onmsite) xx
GREATER ANCHORAGE AREA BOROUGH
Department of Environmental Quality
3330 "C" Street, Anchorage, Alaska 99503 274-4561
Date Received
Time of Inspection
Date of Inspection
FOR
Approval'requested by: ~ :.~
~ ~~C ~. Phone: ~
~ ~ ~ Phone:
~/~ No. of bedrooms
Mailing Address:
2. Property Owner:
Mailing Address:
3. Legal Description:
4. Location:
5. Type of facility to be inspected
Well Data:
A. Type ~. -~-~ B. Depth
C. Constructionf,~_.x'~_~_-~--~/x~.z/~ D. Bacterial Analysis
Sewage Disposal System:
A. Installed
C. Septic Tank: 1. Size
D. Seepage Pit:
E. Disposal Field:
B. Installer
/ ,5",~ oy, 2. Manufacturer
1. Absorption Area~V.~SL(o 2. Material
Total length of lines
8. Distances:
A. Well to: Septic tank 7~! , Absorption area
Nearest lot line/'~ //~ , Other contamination z/'~,/~/~,/.~
B. Foundation to septic tank ~ , Absorption area
C. Absorption area to nearest lot line ~ ~'-'
EQ-034 (1/74) Page 1 of two pages
Page 2 of two p.a. ges - Re~c"~t for Approval of Individual ~r & Water Facilities
L'egal Description
Comments
Approved ~ ~-/¢-'~_.../"__._,..,~. Disapproved Date
Approval.Valid for one year from date signed
Greater Anchorage Area Borough, Department of Environmental Quality
DIAGRAM OF SYSTEM
)
certify that the information contained in this request for approval to be a true and
ccurate representation of the subject sewer and water facilities and these facilities
are operating satisfactorily.
SIGNED
Date
EQ-034 (7/74)
REQDEST FOR APPROVAL OF
INDIVIDUAL SEWAGE AND WATER FACILITIES
(Fill out in Tmiplicate)
.of person mequesting approval ~ ~
Number.~o~, ~edrooms in house d~~--
Watem Analysis:
Well data:
a0
b.
C,
d.
Type ! .
Distance from well to closest existing om proposee:
1. Sewe 1~ line
2. Septic tank
3. Seepage Area
C~sspool'
5. Property Line
Other sources of Possible contamination, i.e., creeks, lakes,
houses, barn, d~ainage ditch, etc.
Sewage disposal system.
a. Age of system ~)/W~ ._.
b. Septic tank capacity in gallons
c. Name of septic tank manufact~m~.m
1. If "home made" show diagram on revemse Side of this foPm.
Disposal field op seepage pit size and type ~p~ ~t~
1. Distance to p~operty line to house foundation
Percolatlonx Te'st 'Y'esults
f. Percolation Test performed by
Diagram should include
Use the reverse-side of this form to show diagram.
-the following information: ~operty lines;.wetl location, house location,
~ptic tank location, disposal area location, location of percolation test,
a~ direction of ground slope.
The i~£or~tion on this form is true and correct to the best of my knowledge.
Date Signed'
Signature of Applicant
TO BE FILLED OUT BY HEALTH DEPART~.~ENT PERSONNEL
~'T[e above described sanitary facilities are hereby approved, subject to the
i°llow~ng conair'tons:
Conditions :__ ~<) ~- ~_
7
The above described sanitary facilities are dissoproved for the following
reasons: ~
· Signath~% of ~f~i~.i%~ ........ =." ":, ~'' ~ i ' Date ~,'
Approval is valid rom one yeam following the date of approval.
CPJ: cw
VETERAN'S ADM INIST~qATION
The following statement of account is for your information m connection with the sale of
your property.
1o DAT. E OF STATEMENT 2~=~,UNPAiD PRINCl~A~ BALAN
4. INTEREgT ACCRUED THROUGH(~te ~llo~ In Jtem]] 5, BALANCE IN TAX AND INSURANCE ACCOUNT
6, DELINQUENT pAYMENTS (If =ny) 7,AMOUNT ~8, ~y INTEREST RATE
9. INFORMATION ON PAYMENTS AND INSURAN~[
kMOUNT OF MONTHLY PRINCIPAL AND INTEREST $ Y~* ~ ~
iNSTALlMENT APPLIEDTf TAX AND INSURANCE ACCOUNT $ ~. O~ ~ ~e~~7
' AMOUNT OF COVERAGE ~
HAZARD AMOUNT OF PREMIUMS S -~
INSURANCE TERMS ~EXPIRATION DATE OF POLICY
y~
Upon completion of the sale of your home, please send us the information or documents
checked below so that we may adjust our records.
Instrument of conveyance showing recording information.
Evidence showing hazard insurance transferred to the new owner.
Your authorization for transferring funds in the tax and insurance account to the
new owner.
COO ;,
FL 26-580
FEb 1972(RS)
Show veteran's ~#1I name, FA file numbez, and social s~curity number on all correspondence.
If any payments are received or disbursements raade for taxes, insurance, etc., after the date
of this statement or if any checks for payments heretofore credited to the account become
uncollectable, an adjustment will b~ necessary in the tota. 1 a~nount owed, It is important
that you kccp the Veterans Administration informed of your current address as you al'c
liable for this loan until it is repaid in full.
FL 26"580
FEB 1972(R$)
enu e.~,~, qqOg
i
~?