Loading...
HomeMy WebLinkAboutNORTH STAR #1 BLK D1 LT 32.33  MUNICIPALITY OF ANCHORAGE DEPAR'h~ENT OF HEALTH & ENVIRONMENTAL PROTECTION ENVIRONMENTAL ENGINEERING DIVISION 825 L Street- Anchorage, Alaska 99501 Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT NAME ,5'/4/'7/t !_:,V,m.,4 LEGAL DESCRIPTION LOCATION --/ / ' / Harding Dr. & 47th Ave. NO, OF BEDROOMS DISTANCE TO: J Well Absorption area Dwel!ing PERMIT NO. Material Manufacturer ' ~ ' No. of¢ompartments L q. capacity in gallons IF HOMEMADE: Width Liquid depth DISTANCE TO: / PERMIT NO. Manufacturer Well DISTANCE TO: Foundation Nearest lot line Total length of lines Trench width inches No. of lines Length of each line PERMIT NO. Distance between lines Top of tile to finish grade Material beneath tile Total effective absorption area inches Length Width Depth PERMIT NO, Type of crib Crib diameter Crib depth Total effective absorption area Well Building foundation Nearest lot line DISTANCE TO: Class Depth Driller Distance to lot line DISTANCE TO: Building foundation Sewer line Septic tank OTHER PIPE MATERIALS SOIL TEST RATING INSTALLER REMARKS System installed about 1976 per tenant's information. Excavated to determine tank material and depth. Pumped using 2000 gal capacity pumper truck to determine tank capacity. Tank pumped empty on Oct. 15, 1982. Approx 100'×180' whse is used for truck storage and const, office. There are 3 restrooms for the 8 employees with a total estimated sewage flow of about 150 gal per day. DATE PERMIT NO. Absorpt on area(s) 72!013'(Rev. 3178) LEGAL I ~t_~ ]..2;&2 Blk D I Northstar Subd. ' . APPLIC _.i, IT FILLS OUT UPPER HAL...ONLY Buyer JX]~ Address /.~'0/~ ~U~/)~ ~2/J~ /~L.~ Lending Institution ,,/~ /~]A/~',~'~ //~,~//,/~-~ Phone Address /.~¢:..~u~, -/'~ ~4.~/'-~._.. ~'~l Realty Co. & Agent .//~:~.~../>~. 0/~.4../~/~.,9~.~~ -- ./.',,?~/~ ~, b~ce-~ Phone Legal Description ,~,-~ /,. ~ ,, '~ /,.~,,~ ,20/ l{/d'c~ ,.~W'v' r .i , Type of Residence [] Single Family [] Multiple Family~ No. of Bedrooms Water Supply / [~ Individual ATTACH WELL LOG. A well log is required for all wells drilled since June 1975. [] Community For wells drilled prior to that date, give well depth (attach log if available). ~ Public Utility Sewer Disposal [] individual Year Individual Installed: [] Public Utility When Connected to Public Utility: ~ Holding Tank NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED. Time Time Time Time Date Date Date Date Inspector Inspector Inspector I n spec t op.,/~/~ Field Notes: lC PALITY O~ AN~iHoRAG~ Ut:PT (3 ,-- ' ~,NVIRONiV, E['; :A '; .,O .EcTtON ( ) APPROVED BEDROOMS I~,'k.) ~ ~ *CONDITIONS OF APPROVAL ( ) DISAPPROVED CONDITJONAL APPROVAL' DATE Soils Rating Date Sewer Installed Well To Absorption Area Well Log Received Well to Tank Septic Tank Size 72.023 (3182) Tony Know/es Mayor October 13, 1982 AI £H ' RAGE WATER ¢__. SEWER 3000 Arctic Boulevard Anchorage, Alaska 99503 (907) 277-7622 Owned by the Municipality Jk'tUNICIP~LITY OF ANCHORAGO~ Anchorage Dr:~T ~: ;'::'L:- ~ ~', Linda M, Smith Alaska Equities Incorporated 1455 Hillcrest Drive Anchorage, Ak. 99503 Re: [;C T 1 5 1982 RECEIVED Availaibility of Sewer Service to Lots l, 2 & 3, BloCk D-l, North Star Subdivision Dear Linda: The location of the closest sewer main that is capable of serving the subject property is located 190.00 feet west of the west property line of Lot 3. Your property is not served by sewer. The above information is shown on AWWU Drawing #15~5 and is correct. The apparent error of the location is because of Drawing #5599 which was proposed to be built some years ago. Drawing #5599 was NOT constructed, and we have added this to the drawing. As for the trunk assessment, this means that in the future you will not have to pay a trunk assessment. This in itself does not guarantee or necessitate sewer availability, It is the lateral charges and/or private development cost (P.T.E,) which is levied upon connection to the system. Sincerely, Techn i Ci an Anchorage Water & Wastewater Utility JGT/deb