HomeMy WebLinkAboutNORTH WOODS BLK 1 LT 14
, ' Municipality of Anchorage Page [ of 'z
DEPARTMENT OF HEALTH AND HUMAN SERVICES
ENVIRONMENTAL SERVICES DIVISION
P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744
On-Site Wastewater Disposal System and/or Well Inspection Report
Permit Number: ~0 '~O PID Number: O ~l ~ 7 ~| ~4~-~'
Name: ~'l~'~,~, ~¢~ ~A ~ Wastewater System: ~ New ~' Upgrade
Address: ~1
~z~ ~oo~ 0~, ~'~c~ ~ ABSORPTION FIELD
No. of B~roo~s:
Phone: ~ ~ ,~ ~ ~ D Deep Trench ~ Shallow Trench ~ Bed ~ Mound D Other
Total Depth from original grade:
LEGAL DESCRIPTION so,,~.~:j.'z ~s~.~,.
Block: Subdiv~ion: Depth to pipe bosom from original grade: Gravel depth bene{th pipe
Township: ....I~ Range: Section: .. , Fill added above~ ~lqrlginal~ ~grade: Ft. Gravel length: 5~ j Ft.
Number of lines: Dista~ lines:
WELL: ~x~5*,~ New D Upgrade/ Gravel width: ~ Ft, i Ft,
Classification (Private, A,B,C): Tota~ ~ased To: Total absorption area: Pipe material:
~A~ ~t~~t, ~ Ft. Ft. ~Oo SQ. Ft. ~ 03C'~
Driller: ~ Date Drilled: Static Water Level: Installer: Date installed:
y~ Pump Set at: Casing Height Above Ground:
~u ~. ~t. TAN K
SEPARATION DISTANCES ~s~ptic ~ Ho[din~ a S.T.~.P.
To Septic Absorption Lift Holding =ublic/Private Manufacturer: Capacity in gallons:
From Tank Field Station Tank Sewer Lines ~C~ ~ ~[
We]~ ,~ol+ .~O~+ ~ ~ ~ Material: ~T~~ Number of Co~a~ments:
Su dace ~e I ~
Water ~OO~ '~ -- ~ LIFT STATION
LineL°t ~)i ~ j ~ ~ ~ Sizein gallons: Manufacturer:~
Foundation j ~ i ~.~ t ~ ~ ~ "Pump on" level at~~l at: High water alarm at:
Cu~ain
~ - ~ ~10,~ , ~ JElectdcallnspectionspedormedby:
Drain
Remarks: ~,'r~ ~.~ c~,~,~ ~ BENCH MARK
Location and Description:
~O/~T I)~)~ ~ A~umedElevation: ~00 *O
~C~ ~' /~ ',,.'~.
inspections pedormed by: 17a34 ~,e~ mve~ L~ ~==a ~.~S: 1st 1-tZ-fl 4~,~.~~
Eagle River, Alaska995~ 2nd. W.-iz-~ ~ '
~ ~ ~ RO3ERT C. CO'WAN
Department of He~ Ith an ~,n Sewices approval ~,, ,~',,~ .., ..,."..-.
Reviewed and approved b )(~. ] ~ Date: ~1 ~]ff~
72-013 (Rev. 9/91) MOA 25
Perr~it No,
SW950520 2 2
Page of
Municipality of Anchorage
DEPARTMENT OF HEALTH AND HUMAN SERVICES
ENVIRONMENTAL SERVICES DIVISION
P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744
On-Site Wastewater Disposal System and/or Well Inspection Report
LOT 14, BLOCK 1, NORTH WOODS S/D 051-751-67
Legal Description: PID No.:
'lNG
SEPTIC T,NK
DBL1
DBL2
N
EXISTING 1000 GAL
SEPTI( TANK
SCALE 1" = 40'
/
/
/
/
/
CO1 = ,~.0' /
C02 = /
NEW
1250
S.T.
CO1
C02
MT1 66.4
~,6: .4'
WATER
57.4'
ROBERT C. COWAN
CE - 8801
72-013 A (Rev. 9/91) MOA 25
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND HUMAN SERVICES
P.O. BOX 196650, 825 "L" STREET, ROOM 502
ANCHORAGE, ALASKA 99519-6650
PERMIT NUMBER:SW950320
DESIGN ENGINEER:S & S ENGINEERING
OWNER NAME:SWEEP CURTIS W & MARIA A
OWNER ADDRESS:22744 NORTHWOODS DR
CHUGIAK, AK 99567
PARCEL ID:05173167
PAGE 1 OF 1
ON-SITE WASTEWATER DISPOSAL SYSTEM (UPGRADE) PERMIT
DATE ISSUED:10/05/95
EXPIRATION DATE:10/05/96
LEGAL DESCRIPTION:
NORTH WOODS ELK 1 LT 14
LOT SIZE: 28935 (SQ. FT.)
NUMBER OF BEDROOMS: 4 THIS PERMIT: 4
THIS PERMIT IS FOR THE CONSTRUCTION OF:
DISPOSAL FIELD /SEPTIC TANK SYSTEM
ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH:
1. THE ATTACHED APPROVED DESIGN.
2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS
15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL
REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (iSAAC80) .
3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS
PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY
CALLING 343-4744 ( 24 HOURS ) (NOT REQUIRED FOR WELL ONLY PERMIT)
4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL
ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING
WEATHER MUST BE EITHER:
A. OPENED AND CLOSED ON THE SAME DAY
B. COVERED, SEALED AND HEATED TO PREVENT FREEZING
5. THE FOLLOWING SPECIAL PROVISIONS.
SPECIAL PROVISIONS:
DB : ·
ISSUED BY:
DATE:
DATE:/C~/~/,,~3~'-
ROBERT C. COWAN, P.E.
ROBERTA. SHAFER, RE.
September 15, 1995
CIVIL ENGINEERS
(907) 694-2979
FAX (907) 694-1211
HEALTH AUTHORITY
APPROVALS
SEWER&WATER
MAIN EXTENSIONS
SEWER&WATER
INSPECTION
ENGINEERING STUDIES
AND REPORTS
WELL INSPECTION
& FLOW TEST
SITE pLANS
ROAD DESIGN
SOILTEST
PERCOLATION
TEST
STRUCTURAL &
MECHANICAL
INSPECTIONS
ONSITE
WASTEWATER
DISPOSAL SYSTEM
DESIGN
MUNICIPALITY OF ANCHORAGE
Department of H~alth and Human
P.O. Box 196650
Anchorage, AK 99519
REFERENCE: Lot 14; Block I; North Wood6 Subdivision
.~ou~ bed.~om hou,6e, on ,the. re~e~eneed p~o~.
A test hole was excavated and a percolation test performed. The
approximate location of the test hole is located on the attached site
plan.
At the tdme of excavation no water was encountered and after thirteen
day ground water monitoring, water was found at ten fe~t.
Attached is the proposed upgrade design.
This property is served by a Community Water System.
We do not anticipate any adverse effects on neighboring w~lls, septic
systems or drainage patterns by the installation of the proposed
septic system.
If you require additional information please corcC_~o..X: u~.
Sincerely,
obert .
RCC/gk
Enclosure
17034 NORTH EAGLE RIVER LOOP · SUITE 204 · EAGLE RIVER, ALASKA 99577
I~CALE
H ~-~
o~.
.°~
r~
H
SITE PLAN UPGRADE
~ ~----~5
Z ~ ~ I
Municipality of Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L' Street, Anchorage, Alaska 99502-0650
SOILS LOG m PERCOLATION TEST
/'
PERFORMED FOR: ~
LEGAL DESCRIPTION:
1
2
3
4
5
6
7
8
DATE PERFORME
/¢~ X~ownship, Range, Section:
12
13
14
15-
16-
17
18
19
20
"~ ~"~ ,0 / "~ WAS GROUND WATER
· ENCOUNTERED?
IF YES, AT WHAT
DEPTH?
SLOPE SITE PLAN
E
Depth lo Waler After ~
Monitoring? \ c~. Dale: ~ ~"~c-1;~'~
Gross Net Depth to Net
Reading Date Time Time Water Drop
PERCOLATION RATE __
TEST RUN BETWEEN __
(minutes/inch) PERC HOLE DIAMETER
FT AND z.~,.~__~ FT
COMMENTS
PERFORMED BY:
17034 Eagle River Loop ~,~.~ ~'{,,;,. 20~. "~"" ~ ¢' CERTIFY THAT THIS TEST WAS PERFORMED IN
ACCORDANCE WITH
72-008 (Rev. 4/85)
ROBERT C. COWAN, RE.
ROBERTA. SHAFER, P.E.
HEALTH AUTHORI~
APPROVALS
SEWER & WATER
MAIN EXTENSIONS
SEWER&WATER
INSPECTION
ENGINEERING STUDIES
AND REPORTS
WELL iNSPECTION
& FLOW TEST
SITEPLANS
ROAD DESIGN
SOILTEST
PERCOLATION
TEST
STRUCTURAL&
MECHANICAL
INSPECTIONS
ON SITE
WASTEWATER
DISPOSAL SYSTEM
DESIGN
ON-$ZTE OJASTE~JATEI~ P1$POSAL $¥STEU
CO~ISTRUCTZON P~CTZCE$
UATERZAL SPECIFZCATIOHS
CIVIL ENGINEERS
(907) 694-2979
FAX (907) 694-1211
Lot 14;
GE/~ERAL:
I. The scope of this project in,lades the insta~ation of a 1250
gallon septic tank and a five foot wide drainfield to serve
the existing .~o~/~ bedroom residence on the referenced
property.
Construction shall be in accordance with the approved site plan
and design drawings, Municipal permit with any special
provisions or conditions, and all applicable State and
MunicipaI WastewaterDisposalRegulations.
3. The contractor shall be r~sponsible for obtaining any necessary
underground utility locates.
U~ess specifically agreed otherwise, the property owner shat~
be r~sponsible for final grading areas subsequently depressed
from soil s~ling. On all leachfi~ld mound systems, the
property owner shall be responsible for ensuring a satisfactory
vegetation growth over the mounded ~ea.
Contractors installing wast~water disposal systems must be
certified by the Municipal Health Department for system
installations. Owners installing their own systems must also
receive prior approval from the Municipal H~alth Department.
~EPrIc TA~K ZHSTAL~ATZO~:
A Septic tank is to be constructed by a certified septic tank
manufacturer. Construction shall include two 4" cleanouts for
pumping access.
2. The septic tank shall be sufficiently bedded to prevent
s~tling or shifting of the tank.
3. All standpipes on thc septic tank shall extend a minimum of 12
inches above final grade.
4. Septic tan~ installed with less than 4' of cover shall be
insulated.
17034 NORTH EAGLE RIVER LOOP" SUITE 204 · EAGLE RIVER, ALASKA 99577
Page Two
Lot 14; Block I; North Woods Subdivision
J
A foundation cleanout shall be instatled one to four feet from the
building foundation. In the line between the tank and the leachfield
there shall be two adjacent cleanouts (unless an effluent pumping system
exists within the septic tank). These cleanouts shall be located on
undisturbed soil not more than 10' from the tank. The first cleanout,
in line, shall be to clean toward the leachfield. The second cleanout
shall be to clean toward the septic tank.
Final grading over the septic tank shall be such that a positive slope
exists away from the septic tank.
ABSORFFION TRENCI'J/I~.~4~INFIEL~ INSTALLATION:
Excavate the proposed trench to the dimensions shown on the design. The
bottom of the excavation shall be within 2 inches of level. If the
sidewalls of the excavation become smeared, they must be raked or
scratched (roughed-up) before gravel (sewer rock) placement.
Once the gravel is installed, the d~tribution pipe is to be installed
level with the perforations faced downward. Gravel is then to be placed
over the distribution pipe to provide a minimum of 2 inch~s of cover
over the pipe.
A silt barrier must be installed b~tween the final gravel layer and the
native soil backfill. Ensure the silt barrier covers the entire gravel
surface before placing backfill.
Monitor tubes shall be of four (4) inch diameter and inst~ed
approximately in the locations shown on the design. The portion of the
monitoring tube extending through the gravel shall be perforated from
the bottom of the trench to the invert of the distribution pipe. This
is equivalent to the effective depth of the gravel as noted on the
design.
Backfill over the final gravel layer must not be less than twenty-four
(24) inches. Insulation must be installed when the backfill depth is
less than thirty-six (36) inches. The finish grade over the trench must
be mounded to prevent the formation of a depression after settling.
UINIUUU MATERIAL SPECIFICATIONS..
I. Any septic tank proposed for installation must be constructed by a
Municipally approved septic tank manufacturer.
Page Three
Lot 14; Block I; North Woods Subdivision
2. The following pipe materials are approved for use in septic system
installations in the Munieipa~y of Anchorage:
Type of Pipe Perforated
Solid
Cast Iron Yes Yes
ASTM D3034 (PVC) Yes Yes
ASTM F810 (HDPE) Yes No
ASTM D2662 (ABS) Yes Yes
Use of a type of pipe oth~ than listed above must be approved by the
inspecting engineer.
3. Insulation shall be atl~ast 2" thick extruded direct burial polystyrene
(Dow Chemical Company Styrofoam HI or equal).
4. Septic tank inlets and outlets shall be fitted withwat~rtight couplings
(Caulder, Fernco, or equal).
A permeable nontoxic silt barrier (Typar 3401, Mirafi 140/N, or equal)
must be installed between the final leachfield gravel layer and the
native soil backfill.
6. All leachfield gravel (s~wer rock) shall be 0.5"-2.5" screened gravel
with less than 3% passing the #200 sieve.
7. When sand is b~ing used as a filter material, its gradation
specifications must conform to current M.0.A. or D.E.C. requirements.
INSPECTIONS=
Typically there will be a minimum of three (3) inspections required during the
installation of the wast,water disposal system. These inspections will occur a~
follows:
The first inspection must be conducted after the excavation of ditches,
pits, trenches, or bed~ and before the installation of any gravel. A
septic tank may be set in place, but may not be backfilled before this
inspection.
The second inspection must be conducted after th, placement of the silt
barrier, gravel, distribu~on lines, standpipes, cleanouts, and
insulation, but before the placement of any other backfill.
Page Four
Lot 14; Block I; North Woods Subdivision
3. The final inspection is to occur upon final grading of thc property.
Often there will be more than th~se 3 inspections required, especially with the
installation of multiple trenches, sand filters, pressurized distribution
systems, etc. Thus, the inspecting engineer is to be contacted at least 24
hours prior to the start of co~truction. If necessary, a pre-construction
meeting will take place on-site. The inspecting engineer will not coordinate,
direct or control in any way the contractor's activities.
The owner shall contract with the contractor to perform the work outlined in
these specifications and plans and in accordance with the attached M.0.A.
permit. There will be no contractual arrangement existing b~tween the
contractor and S ~ S Engineering. S & S Engineering shall be the owner's
representative and will inspect the work as stated above to document the
contractor's activities. Final acceptance of the contractor's work rests with
the owner and the M.0.A.
S & S Engineering shall have no liability to the owner or to others for acts or
omissions of the contractor or any other persons performing work on this ~pro.ject
or the failure of the contractor to carry out the work in accordance with these
construction documents. S & S Engineering 'S inspecting engineer will not be
responsible for the co~truction means, m~thods, techniques, sequence,
procedures or the safety precautions incident to this project.
CONTRACTOR/INSTALLER
MAILING ADDRES~
LEGAL DESCRIPTION
: ~ MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION
ENVIRONMENTAL ENGINEERING DIVISION
825 L Street- Anchorage, Alaska 99501 Telephone 264-4720
ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
HONE /~NEW
DISTANCE TO: ~ ¢
Manufacturer~
LOCATIQCJ~
Liq, capac tV in gallons
DISTANCE TO: We
DISTANCE TO:
No. of lines /
Lengtil'~f each line
Top of tile to finish grade
Length Width
Absorption area
Inside length
Dwelling
Dwelling
Material
Width
Material
Foundation/ (~ ~ Neare~;~lin~
TM°:t:lr i ~1 b te~n ?:t I~ et; Se I Trench~t%
Depth
Type of crib Crib diameter Crib depth
Well Building foundation
DISTANCE TO:
Depth
DISTANCE TO:
Building foundation
OTHER
Class
INSTALLE~
REMARKS
inches
inches
APPRO D . DATE
Driller
Sewer line
Total effective absorption
Nearest lot line
Distance to lot line
Sept c tank
NO. OF ROOMS
No. o~..pa, r t me nts
Liquid depth
PERMIT NO.
Liquid capacity in gallons
Distance b e t ~,.~2~(~.
Total e~L~2&sgrption area
PERMIT NO.
area
PERMIT NO.
Absorpt on area(si
F'ERH :,.' T'
_ O 3FFF I .- ~.. F'ETE:R '" S CF.:EEl.:'
LE3RL L :14 E~ ± ~.J'Z~E'T.,-. NOOE:,:5 rE;,.."[::, LF.T F.;IZEE
T~ FE !3F SO f FE~SOF::F'TION ':'-": ...... ,'
............ IEH IS' TF'E[.EH
FEET
HR.:.:.TH.H N "tE.F.::I;.: ,'::IF: E,'EF..',ROO.H':-:; = 2: '._:;OTI ~'FT'ir.~G ,.'.'!Sr::~ FT?'F~'",= ~-
.............. - LL ¢ I~l
THE F--.'F '3 11 RE[:, ''"' 1' '%.: ........ -, T ~. ~ ~ r,~ ·
..... :,...~F.. C)F' TFIE F.,F' Tl FIE:SORF"TiFIr.~ Z' '"--','Z.~ IS
TMF ............... L. FH"~7'h [:,It,?F:'Hq"-h! IS 'T'HtE LENGTH ,::II",! FE:ET> F~F' THE T..:'R'F~ ......... '"*'H OF? r-,-,'
- . ~ ~.HINP iEL..E:,.
THE DE:F'TH OF R TR/ENE:H OP .... PiT ,Tq .......... THE [:,T'BTEN-F' ~,,....~'~CT. ,,..,_=,~[:c'~.~ THF'. - ~;UF?F'Fi-E_. OF: THE',.
GROUNE:, !qN[:, THE E F'FTT DH OF THE E~',:F'~R',,'RT T ON < ~ N FEET
THERE :I:S NO :~E:T H!D'FH FOR TRENCHE:5.
THE G~'F.',/EL [:'EF'TH !:E THE HIN!HUH DEF'TH OF' GR!~VEL. E:ETHE:EN THE OLITFF:I! i PTF'F
FiND THE E:O'TI"OH OF 'T[-.E EXCR~,,'FI't*ION <!N FEET>. ' .......
F'EF:H Z T hF F _ Z CRNT HFd: TI-IF F.:[.:.:'SP_- ~-~'~: I £-:~ ! L I 'T'¢ T "_' ~ N.F "X F.'H TH I :~; E:'EF'F!F.':TH.EI'.,!T [>UF.: i NG THFJ
i'NL:;TFfi_LF'T'TF'~N ZBSF'ECTT"N'~ OF FIN'¢ HELLS RD."FI,'-:F'NT TO THiS *:-_- . : '.' . .~.
......... - ..... "k' F'P~T,. FINE:, TFIF~
?.!1 [,1RF'~;.' OF FE(S~F,Fh~'"F":T, 'rHRT T!qF I.,IF ! HILL
................................... :,EF: ,.. .....
F~RF~::'F-'T LING FF FINtr' ':"-":'Tm'l . .
................... H I THOLIT F I NFIL [ N'-:;F'E' I T ! ON RI",ID ~qF'P'~' "_" 'R ..... E~? TH t S
E-"EF'RRTH_F';NT H ~ LL BE SUEL!E:i:"F TO F'RC SEF:.tT T ON.
HiN!h'ILtH [:,IS;TFfi'.,!CE E:ETHEE:N Fl HE:LL..F~N[> F~N"r' ON'-SITE SEi.,.!RGE DI'.E;PO~F)t .......... '::".":'"r'F'l.. -, -,. tfi;
· ~m¢:~ F*EET F'"F' R FR.. P I~:. HELL F "' ..........
UP"tH 'THE I"'¢F'E OF' F'UEILIL-: HELL. -
HIN. IH!.H D:!:STRNCE: FROH FI F'F'I'v'RTE HELL T- F! FKI,-' ....... t E SEHEF;'. ~ TNE '~'~ ';'~'~ F'EE"t .... '~-
' ' ' · ........... P,,.,~L.
TO R COHHLIN!T'¢ SEHEF4: L.!NE I~; '75 FEET.
OTHF'F'_. RE(;:¢JIREHE:NT~5 HFW ~F'FL'¢. 2;F'F'~TF'rCFiTf qN,:::;. , ~i.[ L. Hb,LE TO I N%LIRE PF"Z F'E~;: I NSTFtLLRT I ON.
I CE,r';;:TIF'?' THF!T
i: i RH F'I-~,HILI~F?. HITH THE F:E(;!IJIF:EhlENTS FOR ON-SITE SE.~,.IEF:S ~N[:, I.,.IELL$ RS SET
FOF:TH B'./ 'THE P'!UNICIPF!L I"F'T' OF F!NC:HOF:RGE.
2: I HILL INSTF~L.L "FFIE S'¢STEH !N FiCC:ORE:,FINCE 1.4!TFt THE CO[:,ES.
2:: Z U[',![::,Ef~S"I"F!~.,IB, THFFF THE ON-SITE SE[,.!E~: S"/:~STEH HFI'¢ REQUZRE ENL. RRGEHENT IF' THE
F.~.::,~D~:NL.E Z:, RE!'IUE.,ELE~? ]U ~NL:L. UDE HOfRE THRN :2: E:EDROI3HS.
S; ~ Gh!E't'3 ' ~~~.~_.
PERFORMED FOR:
LEGAL DESCRIPTION:
'.,~.,,VIUNICIPALITY OF ANCHORAGE ',..~./
DEPARTMENT OF HEALTH AND ENV[RONN~ENTAL PROTECTION
Pouch 6-650, Anchorage, Al=ka 90.502 276-222~'
SOILS LOG -- PERCOLATION TEST
1
2
3
..~'~ 4
6-
7
8
9
PERCOLATION
TEST
SLOPE SITE P~N
10
11
_.---12.
'13-
14-
15-
. 16
17
18
19
20
COMMENTS
PERFORMED BY.*
WAS GROUND WATER NO ~
ENCOUNTERED?
O
P
E
IF YES, AT WHAT
DEPTH?
Reading Date Gross Net Depth to Net
Time Time Water Drop
2 '
248-~:
PERCOLATION RArE / / ImI,u,e,n,~h! ~,~.g 5//2.
TERT RUN ~I:T~A/EEI~I '~ FT AND ~ FT
SIGNED
~~. '4S 472
SEND PARTS 1 AND 3 WITH CARBON INTACT -
PART 3 WILL BE RETURNED WITH REPLY.
DETACH AND FILE FOR FOLLOW-UP
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH & HUMAN SERVICES
· DIVISION OF ENVIRONMENTAL SERVICES
CERTIFICATE OF INSPECTION FOR HEALTH AUTHORITY APPROVAL
OF ON-SITE SEWER AND WATER FACILITY
264-4744
Application Date 7/29/88
GENERAL INFORMATION (MUST BE COMPLETED PRIOR TO SUBMITTAL)
(a) Legal Description (include lot, block, subdivision, section, township, range)
Lot 14 Block 1 Northwoods Sec. 4 T15N, R1W
Location (address or directions)
17559 Northwoods Drive Peters Creek, AK
(b) Property Owner .g¢.c. of: HUD Telephone: Home
Mailing Address Attn: Single Family Property Dispo.
(c) Lending Institution n/a Telephone
Mailing Address
Business 271-4665
64 An~h~o~ QQq~q-0001
(d) Real Estate Company and Agent
Address
Telephone
Mail the HAA to the followin(~ address: or: Check here I~, if hold for pick up.
List contact person and day phone number below.
Engineer - 694-5195
(e)
TYPE OF RESIDENCE
Single-Family [~
Number of Bedrooms"
WATER SUPPLY
Individual Well [] CommunityJ~] Public []
Note: If community well system, must have written confirmation from the State Department of Environmental Conservation
attesting to the legality and status.
SEWAGE DISPOSAL
Onsite ~ Public [] Community [] Holding Tank []
Note: If community well system, must have written confirmation from the State Department of Environmental Conservation
attesting to the legality and status.
Page I of 2
72-025 fRev 8/861 Front
ENGINEERING FIRM PROVIDING INSPECTIONS, TESTS, FILE SEARCH, DATA AND INFORMATION
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health
Authority Approval shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained
from the Municipality of Anchorage flies and from my investigation and inspect[on, the on-site water supply and/or
wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on
the date of this inspection.
Name of Firm P~a¢]e, Riv~.r EngiJr~eer±n¢ Se~m,"ices Telephone 907/694-5195
Address P.O. Box 773294 Eaqle River, AK 99577
Date
DHHS APPROVAL
Approved for ~.'7~Z ~.) bedrooms by
Approved ~/~.~.._ Disapproved
Terms of Conditional Approval
Conditional
Date
CAUTION
The Municipality of Anchorage Department of Health and Human Services /DHHS) issues Health Authority Approval
certificates based only upon the representations given in paragraph 5 above by an independent professional engineer
registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes and their lending institutions in
order to satisfy certain federal and state requirements. Employees of DHHS do not conduct inspections or analyze data
before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the professional
engineer's work.
Page 2 of 2
72-0251Rev 8/86) Back
MUNICIPALITY ~F ANCHORAGE (MO~/
HEALTH AUTHORITY APPROVAL (HAA)
CHECKLIST - FEBRUARY 1984
264-4720
Legal Description:
Well Classification ~,/e ~'.r ~J~
Well Log Present (Y/N)
Total Depth Cased to
Static Water Level
Casing Height Above Ground
Electrical Wiring in Conduit (Y/N)
Separation Distances from Well:
To Septic/Holding Tank on Lot
To Nearest Edge of Absorption Field on Lot
To Nearest Public Sewer Line
Cleanout/Manhole
Water Sample Collected by
Water Sample Test Results
,y
If A, B, C, D.E.C. Approved (Y/N)
Date Completed Yield
Depth of Grouting
Pump Set At
Sanitary Seal on Casing (Y/N)
Depression Around Wellhead (Y/N)
; On Adjoining Lots
; On Adjoining Lots
To Nearest Public Sewer
To Nearest Sewer Service Line on Lot
; Date
Comments
B. SEPTIC/HOLDING TANK DATA
Date Installed Size
Standpipes (Y/N) Y Air-tight Caps (Y/N)
Depression over Tank (Y/N)
Pumping/Maintenance Contract on File (Y/N)
Holding Tank High-Water Alarm (Y/N)
Separation Distances from Septic/Holding Tank:
To Water-Supply Well '/"'..2.,~ ~
To Property Line -y-~o ~
To Water Main/Service Line
No. of Compartments
Foundation Cleanout (Y/N)
Date Last Pumped ~j~
; for
Temporary Holding Tank Permit (Y/N)
To Building Foundation // z
To Disposal Field ~"
To Stream, Pond, Lake, or Major Drainage
Course
Comments
Page 1 of 2
72-026(11/84)
C. ABSORPTION FIELD DATA
Soils Rating in Absorption Strata
Date Installed
Width of Field
Square Feet of Absorption Area
Depression over Field (Y/N)
Results of Last Adequacy Test ,..~',~/:,,~ ~ ~./'w,,-,~
Separation Distance from Absorption Field:
To Water-Supply Well
To Building Foundation
Lot
To Water Main/Service Line
To Stream/Pond/Lake/or Major Drainage Course
To Driveway, Parking Area, or Vehicle Storage Area
Comments
Type of System Design
Length of Field '~ t
Depth of Field /1, :~ /
Gravel Bed Thickness ,~o /
Standpipes Present (Y/N)
Date of Last Adequacy Test
Y
/
To Property Line /-~'
To Existing or Abandoned System on
; On Adjoining Lots ¢- ~o "'
To Cutbank (if present) ,,1///?
LIFT STATION
Date Installed
Size in Gallons
"Pump On" Level at
High Water Alarm Level at
Tested for
Electrical Codes (Y/N)
Dimensions
Manhole/Access (Y/N)
"Pump Off" Level at
Vent (Y/N)
Pumping Cycles during Adequacy Test. Meets MOA
Comments
** Check Permitted Bedroom Rating Against HAA Request **
I certify that I have checked, verified, or conformed to all MOA and HAA guidelines in effect on the date of this inspection.
Signed ~~4Servjc's. . Date
Date
of
Payment
Page 2 of 2 ·
J U L 2 8 1988
72-026 (11/84)
RECEIVED
3801 C STREET, SUITE 1334
ANCHORAGE, ALASKA 99503
STEVE COWPER, C;OVERNOR
5~3-6775
DATE: _'7__Z/'_~_/'/_~'~_ .........
To Whom It May Concern:
Accordinq to the records on file in this office, the __¢---_~9~./~.L~ ....
~.~ _C/.~A/_6_/C._'~__~J~_O_~ ........ Uater System iS in compliance with the
State of Alaska Drinking Water Regulations.
Sincerely,
Environm~nta~ Field Officer
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION
DIVISION OF ENVIRONMENTAL HEALTH
CERTIFICATE OF INSPECTION FOR HEALTH AUTHORITY APPROVAL
OF ON-SITE SEWER AND WATER FACILITY
264-4720
GENERAL INFORMATION
(a)
Leg.al Description (include lot, block, subdivis, ion, section, township, range)
Location (address or directions)
Applicant Nam~~ b ~ Telephone: Home ~,
~pplicant is ~check ~e): ken¢in~ Institution ~: Owner/buiMor ~; Bu~or
(b)
(c)
(d) Lending Institution '_~/~,./'-" ., ?~-~'¢'~ .,. ~. ¢" ,/'-'~?',¢'~ /~ %'rd * Telephone
Address C ~_~. .4~¢.~' / )~:-~/-~A ~'
(e) Real Estate Company'and Agent -~ ~-~'~{'~ F'r~~ 4"~ --~
Address
Telephone
(f) ~-~'~/HAA to the following address:
~H. 694-2979
TYPE OF RESIDENCE
Single-FamilyK Multi-Family I-1
Number of Bedrooms
Other
WATER SUPPLY
Individual Well [] Community,~ Public/~
Note: If community well system, must have written confirmation from the State Department of Environmental Conservation
attesting to the legality and status.
4. SEWAGE DISPOSAL
OnsiteA Public [] Community [] Holding Tank []
Note: If community well system, must have written confirmation from the State Department of Environmental Conservation
attesting to the legality and status.
Page 1 of 2 72-025 (11/84)
from the Municipality of Anchorage files and from Fr, y mvest~gat'.on and inspection, the o,msi~e V.,ator
wastewater disposal system is in compliance ~ ~" M. unic~pal and Staid codes, ord~nancos, and regu!abons ~n effect on
the date of this inspection.
Name of Firm _
Address
Date
Telephone
Approved for ~ [~'~( ~l bedrooms by~
Approved ~ Disapproved Conditional
Terms of Conditional Approval
CAUTION
The Muncipality of Anchorage Department of Health and Environmental Protection (DHEP) issues ltea!th Authority
AppFovat certificates based Solely upon the representations given m paragraph 5 above by an independent pFo~essional
engineer registered in the State of Alaska, The DHEP does this F~.s a courtesy to purchasers ol homes and their lending
institutions in order tO Satisfy certain federal and state requirements, Employees ol DHEP do not coRduct inspections or
analyze dat~ before a certificate is issued, The Municipality of Anchorage is not responsible for errors OF omlsSIOFIS in the
professional engineer's work.
Page 2 of 2
"'~'? 'MUNICIPALITY OF ANCHOP, AG~
MUNICIPALITY OF ANCHORAGE (MOA) DEPT. OF HEALTH 8,
HEALTH AUTHORITY APPROVAL (HAA) ENVIRONMENTAL PROTECTION
CHECKLIST- FEBRUARY 1984
264-4720 I,;A'? 0 6 IOD~
LegalDescription: ~ ~ l~~/~ ~
WELL DATA
Well
GlassificatJon
If
A, B, G, D.E.G. ApprovedL~r~/4~
Well Log Present (Y/N) Date Oompleted Yield
,/x.)~epth of Grouting
Pump Set At
Sanitary Seal on Casing (Y/N)
Depression Around Wellhead (Y/N)
; On Adjoining Lots
; On Adjoining Lots
To Nearest Public Sewer
To Nearest Sewer Service Line on Lot
Date
Total Depth Cased to
Static Water Level
Casing Height Above Ground
Electrical Wiring in Conduit (Y/N)
Separation Distances from Well:
To Septic/Holding Tank on Lot ~=~-~:;'"P
To Nearest Edge of Absorption Field on Lot ~¢
To Nearest Public Sewer Line
Cleanout/Manhole
Water Sample Collected by
Water Sample Test Results
Comments
B. SEPTIC/HOLDING TANK DATA
Date Installed ~0/¢/'
Stand pipes (~),N-)~
Depression over Tank-Cr~
Pumping/Maintenance Contract on File (Y/N)
Holding Tank High-Water Alarm (Y/N)
Separation Distances from Septic/Holding Tank:
To Water-Supply Well ~O/~
To Property Line ,~
To Water Main/Service Line
Course
Comments
Size //'~'¢ ~'~ Nc. of Compartments
Air-tight Caps ~/N-)-- Foundation CleanOut-(N~)
Date Last Pumped k-.-~//~ ~-~
Temporary Holding Tank Permit (Y/N)
To Building Foundation
To Disposal Field ~
To Stream, Pond, Lake, or Major Drainage
Page 1 of 2
72-026(11/84)
ABSORPTION FIELD DATA
Soils Rating in Absorption Strata / ?~ ¢///~/~ Type of System Design
Date Installed / 9///-~///'~P'/' Length of Field
Width of Field CJ~/-- Depth of Field
~/' Gravel Bed Thickness
Square Feet of Absorption Area ~'-'/O Standpipes Present~N-~
Depression over Field (-~ Date of Last Adequacy Test ~'---~ -
Results of Last Adequacy Test J'~¢¢ 'r r,~ t¢: ~,- ~ 'T'~ f2~"
Separation Distance from Absorption Field:
"~- 0>2~ /
To Water-Supply Well ~ ~' To Property Line
To Building Foundation ' To Existing or Abandoned System on
Lot /'G/'///~' ; On Adjoining Lots ~'~
To Water Main/Service Line To Cutbank (if present) .'~-/'//~-
To Stream/Pond/Lake/or Major Drainage Course
To Driveway, Parking Area, or Vehicle Storage Area
Comments
D. LIFT STATION
Date Installed Dimensions
Size in Gallons
"Pump On" Level at
High Water Alarm Level at
Tested for
Electrical Codes (Y/N)
Man hole/,~ccess (Y/N)
_ "Purr~ Off" Level at
/ 7~~/en` (Y/N)
./ t.. / ~' Pumping Cycles during Adequacy Test. Meets MOA
/
Comments
** Check Permitted Bedroom Rating Against HAA Request **
I certify that I have checked, verified, or conformed to all MOA and HAA guidelines in effect on the date of this inspection.
Receipt No.
Date of Payment
Amount: *
MD(~tAe N 0 .~"~"~.% ¢~
Page 2 of 2
72-026 (11/84)
ANCHORAGE/WESTERN DISTRICT OFFICE
437 "E" STREET, SUITE 303
ANCHORAGE, ALASKA g9501
BILL SHEFFIELD, GOVERNOR
Telephone:
Address:
274-2533
To Whom it May Concern:
~_/~ ~]~,~ Water System is in compliance with the sta~e Drinking
Water Regulations
Time , Time
Date Date Date
Inspector Inspector Inspector
Comments Conditional Approval
3.;Z
Date Sewer Installed Permit No. Septic Tank Size
Holding Tank Size
Soils Rating Well To Absorption Area Well Log Received
Well to Tank
APPLICANT FILLS OUT LOWER HALF ONLY
Property Owner t]ethard construction, Inc. Phone
SIVA Dot. 1698-K, Anchorage, Alaska 99507 345-1615
Mailing Address
Buyer Delbert L. and Deloris Ao Crowder
PO Box 2804, ~-almer, Alaska 99645
Address
Lending Institution First l*'ederc~l SaviTtgs And Loan Phone
Address ~' a~d Northern Ligb. ts Blvd. 274-6565
',' '¢~ . Will Eason Phone
Realty Co. & Agent }~,E/.[',_~-~- Properties, Inc Attn
2702 Gambell St. , ste. 101~,Anchorage, AK 99503 276-2761
Address
Legal Description LOt 1~ D]_OCk t, North~ooods
NL:-~ North Woods Drive
Street Location
Type~f Residence
'E~ Single Family 3
[] Multiple Family No. of Bedrooms
[] Other
Water Supply
~ Individual ATTACH WELL LOG. A well log is required for all wells drilled since June
Community 1975. For wells drilled prior to that date, give well depth (attach log if
[] Public Utility available.)
Sewage Disposal
E~ Individual Year Individual Installed: 198 1
[] Public Utility When Connected to Public Utility:_
[] Holding Tank
NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED.
ALASKA enulRonmenTAL CONTROL SeRUIC $, Inc.
~ngineerinq S ~nuironmenld Studies
,Mamch 8, 1982
Bethar d Construction
SRA Box 1698-K
Anchorage, Alaska 99507
Dear Mr. Bethard:
On March 5, 1982 I inspected the standpipes on the sewer
system on Lot 14 Block i Northwoods Subdivision. The sumo pipe
was free of--'-~ter~sep~io tan~-~ ha~ a'pproxi'mately 4 f~et of
water in it. The standpipe for the second compartment was
broken and ice was noted in both compartments off the tank.
This could cause some problems if the ice freezes over the
outlet pipe.
Since the house is now occupied, the additional heated
water may melt the i~e~
.~-..~:,~ ..~o~.,~" ~,~,~]~. Sincerely;
C. ed Jr, PhD, PE
President '~
1220 West 25th/~uenue · ~nchora§e, ~lasl~a 99503 · (907) 276-1361