ON-SITE WASTEWATER INSPECTION REPORT
Permit Number: OSP191279 PID Number. 051-731-46 ❑ New ■ Upgrade
Name:
MICHAEL ROURIK
ABSORPTION FIELD
�ound
❑ Deep Trench ❑ Shallow Trench ❑ Bed
Address:
22607 NORTHWOODS DRIVE, CHUGIAK, AK 99567
❑ Other
Phone: No. of Bedrooms:
Soil Rating:
Total Depth from origin de:
907-306-6523 3
GPD/Sq. FL
FL
LEGAL DESCRIPTION
Depth to pipe invert from original grade:
Grave pth beneath pipe:
F
FL
Subdivision: Block: Lot:
Fill added above original grade: G
Gravel length:
NORTHWOODS 3 36
FL
FL
Township: Range: Section:
Gravel width:
FL
Beds Number of lines:
Distance between lines:
FL
SEPARATION
DISTANCES
Total absorp ' area:
Number of trenches:
Dist between trenches'
To
Septic
Absorption
Lift
Holding
Public/Private
From
Tank
Field
Station
Tank
Sewer Lines
so. Ft
FL
Well
N/A
N/A
-
251+
TANK ❑ Septic ■ S.T.E.P. ❑Holding ❑ Other
Manufacturer.
ANCHORGE TANK
Capacity.
1500 Gal.
Surface water
100'+
K
100'+
-
Lot Line
51+
5'+
-
Material:
Number of compartments:
w
N/A
EPDXY COATED STEEL
2
LIFT STATION
Foundation
10'+
10'+
-
Curtain Drain
NONE KNOWN
Manufacturer.
Capacity.
ANCHORAGE TANK
1500 Gal.
Remarks:
"Pump on" level at-
38"
'Pump off level at
34"
High water alarm at
43"
Pump Make & Model:
Electrical Inspections performed by.
20 OSI 05 HHF
CAPSTONE ELECTRIC
PIPE MATERIAL
HDPE
House to tank D3034 Tank to SDR -15
drainfield
Installer A+ HOME SERVICES
Drainfield EXISITNG CO/MT EXISTING
Inspector GEG, Ltd.
BENCH MARK (Assumed elevation)
100.00 FL
Inspection
Location and Description:
Lo
Dates: 1 St 9/19/2019 2nd
3rd - 4th
FRONT DOOR THRESHOLD
ENGINEER'S SEAL
Community Development Department Approval
.�.�� OF �; IllrAt
. ,• ••.••�"�7'♦♦#
�P••
Conditional Date:
approval:
Ar 9
J11'. ..,....... .....
.
............. .. . 0
•
ei f A. arness :,—a
CE -79 3 .•°��i
�.♦♦��
q q
••
'� i
♦ Fp P•Qt1. , . ••N�.
Approved: Date: I 1 I
LICENSE e1:;`5;,0
#AECC884
Inspection Report_1-1-12doc
PERMIT NUMBER:
OSP191279 I
----------------
INSTALLED
--------------INSTALLED NEW 1.25"
HDPE PRESSURIZED
SEWER LINE—
SEPTIC INSTALLATION NOTES:
t 11 1. PER THE CONTRACTOR, A NEW PRESSURIZED
CCC�III` SEWER LINE WAS INSTALLED FROM THE S.T.E.P. TANK
TO THE EXISTING DRAINFIELDS, NEW FLUSHING
VALVES WERE INSTALLED AT EACH END OF THE
DRAINFIELDS ON THE DISTRIBUTION LINES, AND THE
DISTRIBUTION LINES WERE FLUSHED/CLEANED BY A+
HOME SERIVCES.
2. PER THE CONTRACTOR, THE NEW 1.25" PRESSURIZED
SEWER LINE WAS INSTALLED SO THAT IT WILL
COMPLETELY DRAIN AFTER EACH PUMP CYCLE, THE
LINE WAS BEDDED SO THERE ARE NO BELLIES, AND
THE SEWER LINE WAS INSULATED WITH 4" BY 4' WIDE
OF RIGID INSULATION CENTERED OVER PIPE.
A B
E
18.0 34.0
17.3 46.519.1 54.3
NOTE: OLD 1250 GALLON STEEL STEP
TANK WAS DECOMMISSIONED PER
UPC PER CONTRACTOR.
NEW 1500 GALLON EPDXY COATED STEEL
S.T.E.P. TANK PROVIDED BY ANCHORAGE TAI
ECORD DRAWING
)STALLED FLUSHING VALVES ON
EACH END OF DRAINFIELD FOR
FLUSHING DISTRIBUTION LINE
— EXISTING PRESSURIZED
DRAINFIELD. PASSED
ADEQUACY TEST ON 5/14/2019.
LOCATION OF FENCE
Im
EXISTING
I SHED
•r.
3 BEDROOM
; :,,
HOUSE
;
- ----- .�
•):i -
SHED
FCO �\
;'• " �N r:
15'
PARCEL ID NUMBER:
051-731-46
—WATER LINE ENTERS
HOUSE APPROXIMATELY
HERE PER PROFESSIONAL
LOCATES. PROVIDED BY
THE CONTRACTOR
LOCATION OF
WATER LINE
-- I KEYBOX ---
APPROXIMATE LOCATION OF
NORTHWOODS DRIVE ABANDONED 1981 DRAINFIELD
o
..51P••••• •. ••♦1
L j i C,
AV
Y
GARNESS ENGINEERING GROUP, Ltd .! *';
...3....... 9: ti . ................::...
- -- = CIVIL & ENVIRONMENTAL ENGINEERS------------- -� r /((ff 0
3701 E. TUDOR ROAD, SUITE 101 • ANCHORAGE, AK 99507 • PHONE (907) 337-6179' FAX (907) 338.3246' WEBSITE: www.gamessengineeeng.00m •i•••`• � .n....
PREPARED FOR: PHONE NUMBER: PAGE NUMBER: �'. Je 'e A. Gayness : �•
CRW ENGINEERING GROUP, LLC 907-562-3252 2 OF 3 •��% :� CI= -79 _�
PROJECT/LEGAL DESCRIPTION: DRAWN BY: ♦�♦��•';.� J O// ?� 11 p.��` ����
TYPE OF
R DRWOODS S/D; BLOCK 3, LOT 36 DarE.L M o
♦� ��pROFESS�O'o��•
RECORD DRAWING OF SEPTIC TANK UPGRADE 9/30/2019 #AEC 8E1������� 84
..,;.;.•
15'
PARCEL ID NUMBER:
051-731-46
—WATER LINE ENTERS
HOUSE APPROXIMATELY
HERE PER PROFESSIONAL
LOCATES. PROVIDED BY
THE CONTRACTOR
LOCATION OF
WATER LINE
-- I KEYBOX ---
APPROXIMATE LOCATION OF
NORTHWOODS DRIVE ABANDONED 1981 DRAINFIELD
o
..51P••••• •. ••♦1
L j i C,
AV
Y
GARNESS ENGINEERING GROUP, Ltd .! *';
...3....... 9: ti . ................::...
- -- = CIVIL & ENVIRONMENTAL ENGINEERS------------- -� r /((ff 0
3701 E. TUDOR ROAD, SUITE 101 • ANCHORAGE, AK 99507 • PHONE (907) 337-6179' FAX (907) 338.3246' WEBSITE: www.gamessengineeeng.00m •i•••`• � .n....
PREPARED FOR: PHONE NUMBER: PAGE NUMBER: �'. Je 'e A. Gayness : �•
CRW ENGINEERING GROUP, LLC 907-562-3252 2 OF 3 •��% :� CI= -79 _�
PROJECT/LEGAL DESCRIPTION: DRAWN BY: ♦�♦��•';.� J O// ?� 11 p.��` ����
TYPE OF
R DRWOODS S/D; BLOCK 3, LOT 36 DarE.L M o
♦� ��pROFESS�O'o��•
RECORD DRAWING OF SEPTIC TANK UPGRADE 9/30/2019 #AEC 8E1������� 84
PERMIT NUMBER:
OSP191279 RECORD DRAWING PARCEL ID1NUMBER:
051-731-46
TOP OF N
TOP OF T
INLET =
INVERT
@ INLE
GARNESS ENGINEERING GROUP, Ltd
-- CIVIL & ENVIRONMENTAL ENGINEERS=- - -1
3701 E. TUDOR ROAD, SUITE 101 -ANCHORAGE, AK 99507' PHONE (907) 337-6179' FAX (907) 338-3246' WEBSITE: www.gamewengineedng.mm
PREPARED FOR: PHONE NUMBER: PAGE NUMBER:
CRW ENGINEERING GROUP, LLC 907-562-3252 3 OF 3
PROJECT/LEGAL DESCRIPTION: DRAWN BY:
NORTHWOODS S/D; BLOCK 3, LOT 36 J.L.M.
TYPE OF WORK: DATE:
�, RECORD DRAWING OF SEPTIC TANK UPGRADE 9/30/2019
HOLE = 99.95
I OF TANK @
TLET = 94.56
Aw
♦.. ...."................. ...... .....% 3 .0 .
ff Gar Iss ;w;
L' AV
AV
°. ••• 0 �, .�• • 1
Fo ..
LICENSE 1e� OFESS :SO
#AECC884 �"`� /
E L E C T R I C
EST 2012.
Letter of Completion
Date: 9.24.19
A Plus Home Services
7501 E. 140'" Ave.
Anchorage, AK 99516
To Whom It May Concern,
Capstone Electric has installed and completed the electrical portion of the work
located at 22607 Northwoods Dr. Chu2iak. AK 99567. All wiring and installation of electrical
components were installed in accordance with the latest electrical codes and were found to be in
proper working order after final testing. All alarms are functioning and installed in the proper
locations. Because this site is outside the MUNI inspection area please accept this letter as final
inspection for the work that has been done.
Devin Rafeedie
CEO
20828 Bill Stephens Dr. Suite C1 Chugiak, AK 99567
Phone: 907.688.2751 accounting@capstoneak.com r-
i
Jeff Garness
From: Jody Maus
Sent: Monday, September 30, 2019 11:29 AM
To: Tom Varney; Sam Arias
Cc: aplus@gci.net; Jeff Garness
Subject: Northwood STEP tank float settings
Tom and Sam,
According to Mike w/ -A+, the on/off float is set at 28" below the top of the basket and the high water alarm is set at 23"
below the top of the basket. According to you, the basket is 64" tall. This would make the floats at 36" from the bottom
of the basket/tank for the On/Off float and 41" from the bottom of the basket/tank for the, High Water float. Assuming a
2" swing up and down for the float, the "Off' level would be 34", the "On" level would be 38", and the "High Level"
would be 43". We need to know what the tank liquid capacity would be with the floats set at these levels or if they need
to be adjusted to make sure the minimum tank liquid capacity Is met for this installation.
Sincerely,
Jody Maus
Consultant
Garness Engineering -Group, Ltd.
3701 E. Tudor Road, Suite 101
Anchorage, Alaska 99507
Phone: (907) 337-6179
Fax: (907) 338-3246
Mobile: (907) 223-0555
Website: www.garnessengineering.com
dv,ncev rti�emc��s,—rtm coRt�RnT1aH
GARNESS ENGINEERING GROUP, Ltd o - - A,t,,�o.edAWaDiv tutor
-v_-- ENGINEERING • SALES• CONSULTING•zv- �� - r==
Jody Maus
From: Jody Maus
Sent: Monday, September 30, 2019 10:57 AM
To: 'aplus@gci.net'
Cc: Jeff Garness
Subject: Northwoods; Block 3, Lot 36
Attachments: doc06501720190930104704.pdf
Mike,
Attached is a Draft of the Inspection Report and record drawings for the subject property. Please review and let us know
if everything on the record drawing is accurate and true, especially in regard to the septic installation notes on page 2 of
3. Please email us back after review with your statement of accuracy and/or if we need to make any changes, additional
notes, etc.
Sincerely,
Jody Maus
Consultant
Garness Engineering Group, Ltd.
3701 E. Tudor Road, Suite 101
Anchorage, Alaska 99507
Phone: (907) 337-6179
Fax: (907) 338-3246
Mobile: (907) 223-0555
Website: www.garnessengineering.com
-----Original Message -----
From: Scan <Scan@garnessengineering.com>
Sent: Monday, September 30, 2019 10:47 AM
To: Jody Maus <Jody@garnessengineering.com>
Subject:
Garness Scans
DO NOT REPLY TO ADDRESS
Jeff Garness
From:
Beverly Blakeslee <apius@gci.net>
Sent:
Monday, October 7, 2019 7:45 AM
To:
Jeff Garness
Subject:
Documentarion of Statement re: Northwoods
Good Morning Jeff,
Everything on record regarding the documentation and statement of record is acceptable at the Northwoods property.
Thank You
A+ Home Services, Inc.
Mike Blakeslee
Municipality of Anchorage
On -Site Water and Wastewater Program
P.O. Box 196550 4700 Elmore Road
Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997
http://Www.muni.org/onsite
Review Comments
Engineer: GARNESS ENGINEERING GROUP LTD
Legal Description: NORTH WOODS BLK 3 LT 36
Parcel ID:
05173146000
Permit:
OSP191279 SepticTank
Report Type:
As Built Review
lllgnr S,
r,
Q� r
Department
Completed By:
11/19/2019
The application has been reviewed and the following comments have been generated. These are to be satisfactorily
addressed prior to MOA approval:
NA
1. Please verify "Tank to drainfield" pipe material is approve for this application (it is not one of the pip materials listed
in our Component Parts & Materials Guide). — i�nf G �9�-i� Plf"F �+w r Wni �� �' �� �_� i s IQ r�r�n
rnvCrC NS'im 0- � iau iS SiA,�ytp {i�'e :-v!L i.,lA'rNti- Ur'c+
2. Please confirm whether monitoring tubes in existing field were repaired (permit drawing noted that several were
cracked, broke and full of debris). (}+
_
(^�(� 1 � �L ��' i.JiRC ��t�Qc ��ii�YJ •Y'trK .E Ce'y.1i2t4C?GL .� �t 1•�+n11 E 5cK�1Gt i)
I_�l. r C r: j�C' .b J
R.Carroll
V go-,& q
r,R+rrc.-.�e,r}rrr.:-zTc.�sao*;-��r.T-�m-:�?'� •�-��R'3�-r.�e,?�aR�an.�,ny. _ _ _ _
Designee]
O Standa;-.r3 hili e h-nansi(Do, a-IDPE
O Black Pipe
Specifications:
p PE 4710 Resin formulation listed in PPI TR4
p Hydrostatic Design Basis: 1600 psi @ 73 ° F, 1000 psi @ 140 ° F
p Cell Classification per ASTM D3350 = 445574C and 445576C CC3
O ASTM D2239: SIDR 7, 9, 11.5, 15, 19
p ANSI/AWWA C901-17: SIDR 7 Only
p NSF/ANSI Standards: 14 and 61.
Pressure Ratings:
All pressure ratings are a maximum PSI @ 73.4°F.
If temperatures exceed 80°F, contact Charter Plastics for a working pressure de -rating.
Joining:
Charter Plastics Black SIDR pipe is made to ASTM D2239 Standards for inside diameter controlled pipe. It should be
joined with barbed insert fittings and clamps. Double clamping is recommended on 1-1/2" and 2" pipe in all pressures
and on all PC 200 or greater pipes.
You may also use special OD Compression fittings that are designed for ASTM D2239 pipe sizes. Charter Plastics
recommends roughing the end of the pipe with sandpaper prior to sliding on the fitting.
Never use any lubricant on the pipe. Do not expose the pipe to direct flame.
Installing:
All Charter Plastics SIDR Black Potable Water Pipe can be used for down the well applications. For underground
installations, the pipe can be direct buried, plowed or pulled. Buried pipe must be supported by proper embedment
material like sand or gravel. Refer to PPIs "Handbook of Polyethylene Pipe" and follow as local, state or federal
guidelines.
To safely handle and store polyethylene, refer to PPI's Material Handling Guide.
*This pipe is not designed for use inside the building or for hot water applications.
Disinfection:
New water mains and service lines should be disinfected according to AWWA C651.The disinfection should take place
after the initial flushing and pressure testing. Prolonged exposure or concentrated levels of disinfection chemicals
may cause damage to the inside diameter of the pipe.The disinfection chemicals should never contain more than 12%
active chlorine. Charter Plastics recommends the test duration not exceed 24 hours and that upon completion, the
system be thoroughly flushed with fresh water.
Testing: Charter Plastics
All pipe should be hydrostatically tested after installation.
Pneumatic testing is not recommended. Polyethylene. Pipe. Partners. O
Refer to PPI's Handbook of Polyethylene Pipe for Guidelines.
L
O
Z
2
PRODUCT DESCRIPTION
HIGH-DENSITY POLYETHYLENE WATER AND SEWER PIPE
FOR MUNICIPAL AND INDUSTRIAL WATER AND SEWER PIPING SYSTEMS
RICH HISTORY
Thanks to the support of our loyal customers, and the
dedication and hard work from our JM Eagle'" family mem-
bers, JM Eagle7' continues to be the largest manufacturer
of PVC pipe in the United States and in the world.
JM Eagle- was formed in 1982 following the purchase of
eight PVC pipe manufacturing facilities from the Johns -
Manville Corporation. Over the course of the years, we
have expanded our operations through seventeen addi-
tional plants in Wharton, TX; Fontana, CA; Batchelor, LA;
Meadville, PA; Adel, GA; Buchannon, WV, Columbia, MO,
Cameron Park, CA, Hastings, NE, Perris, CA, Sunnyside,
WA, Tacoma, WA, Visalia, CA, and now with the addition
of three Polyethylene (PE) facilities in Kingman, AZ,
Magnolia, AR and Tulsa, OK.
There are only a few pipe manufacturers in the world that
produce both PVC and PE pipe, and we are proud to be
one of them. With our modern PE pipe production facilities
in North America, we are able to fulfill all of our customers'
plastic pipe needs.
DESCRIPTION
JM Eagle- manufactures High -Density Polyethylene
(HDPE) water pressure pipe for municipal and industrial
water transmission systems. This pipe is available for sizes
Y2"-63" in diameter. Our HDPE pipe is recognized in the
industry for its zero leak rate, high performance, and long
HIGH-DENSITY POLYETHYLENE WATER
life expectancy. They may be manufactured with color
striping to identify their application, such as blue stripe for
potable water, green stripe for sewer application, and
purple stripe for reclaimed water.
LONG LAYING LENGTHS
The standard laying length of HDPE pressure water pipe is
40/50 feet. Smaller size pipe 6" and under can be extrud-
ed at continuous coil lengths by request. Longer lengths
provide convenience in installation and allow for significant
cost savings in labor and equipment.
APPLICABLE SPECIFICATIONS
JM Eagle- HDPE water pressure pipe is manufactured
in accordance with AWWA C901/C906, ASTM D2239,
ASTM D2737, ASTM D3035, ASTM F714 and •ANSI/NSF
14/61 listed.
QUALITY CONTROL
JM Eagle"' takes great pride in the quality and workman-
ship of all of our products. JM Eaglee' quality control pro-
grams encompass three critical aspects of the manufac-
turing process: the incoming raw material, pipe produc-
tion, and finished goods. Incoming material is visually
inspected and tested to ensure the material meets all
applicable requirements before its release for production.
During production, the pipe will be visually examined for
any cosmetic defect and pipe samples will be collected for
physical verification and testing for compliance. The fin-
ished product is subjected to further visual inspection to
ensure it has met all the appropriate specifications and
packaging requirements. Without exception, JM Eagle'"
pipe is constantly monitored throughout the entire manu-
facturing process to ensure that it is produced in accor-
dance with all applicable specifications. The JM Eagle -
Quality Management System is ISO 9001:2000 registered.
Copies of the registration certificates are available on our
website at www.imeagle.com.
{e.
CORROSION RESISTANCE
HDPE pipe has excellent corrosion resistance against
electrolytic or galvanic corrosion or any known corrosive
soil or water condition. You don't have to worry about
tuberculation, or the need for costly lining, wrapping, coat-
ing or cathodic protection.
FLOW CAPACITY
JM Eagle- polyethylene pipe has a smooth interior provid-
ing less drag and a lower tendency for turbulence at high
flow. Its superior flow characteristic eliminates scaling and
pitting to preserve its form for consistent flow throughout
the pipe's entire service life. The C Factor is 150 and the
Manning's flow coefficient is .009.
REDUCED INSTALLATION COST
HDPE is lightweight, flexible, and comes in long lengths,
allowing for easier and convenient installation. Because of
its flexible nature, it reduces the use of fittings. HDPE also
allows for non -intrusive installation by offering technology
such as directional boring, pipe bursting and slip lining.
r.
HIGH-DENSITY POLYETHYLENE WATER 3
APPLICATIONS
HIGH-DENSITY POLYETHYLENE WATER AND SEWER PIPE
PE 4710 JM EAGLETM HDPE PRESSURE PIPE PRIMARY PROPERTIES
TABLE 1
—
PPI-TR4
PE 4710
—
ASTM D3350
445574C
g/cm3
ASTM D1505
0.959
g/10
ASTM D1238
< 0.15
minutes
psi
ASTM D790
110,000 to
< 160,000
psi
ASTM D638
3500 to < 4000
Hours
ASTM F1473
> 500
psi
ASTM D2837
1600
Black with
—
—
minimum 2%
carbon black
°F (°C)
ASTM D746
<-130
Shore D
ASTM D2240
> 60
Note: Gray Pipe Cell Classification 445574E
The physical (or chemical) properties of JM Eagle' products described herein represent typical average values obtained in
accordance with accepted test methods and are subject to normal manufacturing variations. They are supplied as a techni-
cal service and are subject to change without notice.
For data, sizes, or classes not reflected in these charts, please contact JM Eagle- for assistance.
HIGH-DENSITY POLYETHYLENE WATER 5
APPLICATIONS
HIGH-DENSITY POLYETHYLENE WATER AND SEWER PIPE
(CONTINUED)
JM EAGLET' HDPE MARKETS AND APPLICATIONS
TABLE 2
Underground Potable Water Distribution,
Mining, Dredging, River/Stream/Lake
MUNICIPAIJINDUSTRIAL Crossing, Highway Drainage, Highway
Crossing, Oil Patch, Agriculture
Water Distribution, Landfill
Storm Water, Culverts, Highway/
Residential/Agricultural Water Collection
Gravity Sewer Systems,
SANITARY SEWER Sewer Force Mains,
Directional Bore
WATER
DISTRIBUTION Potable Water Systems,
Water Service Systems
• Underground Irrigations Systems,
IRRIGATIAgricultural Systems
REHABILITATIONSlip Lining, Pipe Bursting
Water Re -processing Systems
Landfill Gas Collection,
Waste Drainage Systems
Liquid Chemical Mining, Slurry and
Tailing Lines, Mineral Extract System
Heating/Cooling System
for home and business
Factory Mutual (FM) Approved
6 HIGH-DENSITY POLYETHYLENE WATER
I.P.S./D.I.RS.
I.P.S./D.I.P.S.
I.P.S./D.I.RS.
Green Stripe
I.P.S./D.I.RS.
Blue Stripe, C.T.S.
I.P.S./S.I.D.R.
I.P.S./D.I.RS. Gray Slip Liner
I.P.S./D.I.RS. Purple Stripe
60°, 90°,120°, & 180°
Perforated I.P.S./D.I.RS.
I.P.S./D.I.RS.
I.P.S.
I.P.S.
DIMENSIONS AND WEIGHTS
SUBMITTAL AND DATA SHEET
S..D.R. PRESSURE PIPE ASTM D2239
TABLE 7
ANSI/NSF-61,14 LISTED
1/2
0.622
0.089
0.09
0.069
0.07
0.060
0.06
3/
0.824
0.118
0.15
0.092
0.12
0.072
0.09
1
1.049
0.150
0.25
0.117
0.19
0.091
0.14
11/4
1.360
0.197
0.43
0.153
0.33
0.120
0.25
11/2
1.610
0.230
0.59
0.179
0.44
0.140
0.34
2
2.067
0.295
0.97
0.230
0.73
0.180
0.56
3
3.068
-
-
-
-
0.267
1.23
1/2
0.622
0.060
0.06
0.060
0.06
V4
0.824
0.060
0.07
0.060
0.07
1
1.049
0.070
0.11
0.060
0.09
11/4
1.380
0.092
0.19
0.073
0.15
11/z
1.610
0.107
0.25
0.085
020
2
2.067
0.138
0.42
0.109
0.33
3
3.068
0.205
0.93
-
-
I.D.: Inside Diameter
O.D.: Outside Diameter
T.: Wall Thickness
* For data, sizes, or classes not reflected in these charts, please contact JM Eagle" for assistance.
*' Pure -core or solid color.
Note: As of January 1, 2013 JM Eagle's polyethylene SIDR pressure pipe (ASTM D2239) will only be manufacturing with
4710 polyethylene resin. The result is a higher pressure rating for each dimensional ratio (example: SIDR 15 is 125 psi and
SIDR 19 is 100 psi). Please confirm your pressure rating and dimensional requirements before ordering. Please contact
your JM Eagle sales rep for details. (800) 621-4404
14 HIGH-DENSITY POLYETHYLENE WATER
DIMENSIONS AND WEI
SUBMITTAL AND DATA SHEET
(CONTINUED)
REFERENCE STANDARDS
G HTS
ASTM D638
Standard Test Method for Tensile Properties of Plastics
ASTM D746
Standard Test Method for Brittleness Temperature of Plastics and Elastomers by Impact
Standard Test Methods for Flexural Properties of Unreinforced and Reinforced Plastics and
ASTM D790
Electrical Insulation Materials
ASTM D1238
Standard Test Method for Melt Flow Rates of Thermoplastics by Extrusion Plastometer
ASTM D1505
Standard Test Method for Density of Plastics by the Density -Gradient Technique
Standard Specification for Polyethylene (PE) Plastic Pipe (S.I.D.R.-PR) Based on Controlled
ASTM D2239
Inside Diameter
ASTM D2657
Standard Practice for Heat Fusion Joining of Polyolefin Pipe and Fittings
ASTM D2737
Standard Specification for Polyethylene (PE) Plastic Tubing
ASTM D2774
Standard Practice for Underground Installation of Thermoplastic Pressure Piping
Standard Test Method for Obtaining Hydrostatic Design Basis for Thermoplastic
ASTM D2837
Pipe Materials
Standard Specifications for Polyethylene (PE) Plastic Pipe (DR -PR) Based on Controlled
ASTM D3035
Outside Diameter
ASTM D3350
Standard Specification for Polyethylene Plastic Pipe and Fittings Material
ASTM F412
Standard Terminology Relating to Plastic Piping Systems.
Standard Specification for Polyethylene (PE) Plastic Pipe (S.D.R.-PR) Based on
ASTM F714
Outside Diameter
Standard Test Method for Notch Tensile to Measure the Resistance to Slow Crack Growth
ASTM F1473
of Polyethylene Pipes and Resins
AWWA C901
Polyethylene (PE) Pressure Pipe and Tubing, 1/2 in. Through 3 in. For Water Service
Polyethylene (PE) Pressure Pipe and Fittings, 4 in. Through 63 in., For Water Distribution
AWWA C906
and Transmission
NSF Standard 14
Plastics Piping System Components and Related Materials
NSF Standard 61
Drinking Water System Components - Health Effects
FM Approved
Factory Mutual Approval for Underground Fire Protection Service
HIGH-DENSITY POLYETHYLENE WATER 15
•
MUNICIPALITY OF ANCHORAGE
On-Site Water & Wastewater Program s.
.—'.. PO Box 196650 4700 Elmore Road �-
Anchorage,Alaska 99519-6650 Phone:(907)343-7904 Fax:(907)343-7997
" • http://www.muni.org/onsite •`,
Department
On-Site Wastewater Disposal System Permit
Permit Number: OSP191279 Effective Date: 7/10/2019
Work Type: SepticTank Upgrade Expiration Date: 7/9/2020
Tax Code Number: 05173146000
Site Legal Address: NORTH WOODS BLK 3 LT 36 G:1459
Site Mailing Address: 22607 NORTHWOODS DR, Chugiak
Owner: ROURICK MICHAEL J Lot Size in Sq Ft: 20122
Design Engineer: GARNESS ENGINEERING GROUP LTD Total Bedrooms: 3
This permit is for the construction of:
❑ Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy 0 Private Well 0 Water Storage
All construction shall be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80)
3. The wastewater code requires inspections during the installation. The engineer shall notify the Development
Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
shall be either:
a. Opened and Closed on the same day, or
b. Covered, sealed, and heated to prevent freezing
Special Provisions: Contractor shall have water service line professionally located to ensure minimum 10 ft
separation between septic tanks and water service line.
Received By: �-� / Date: 7 Z Cr
<
&-"Ci-co-(9
Issued BY� � A Date: 7 to
MUNICIPALITY OF ANCHORA - X56 89 ,0
• Q. 1411111/ -,5
i 7n
1Communit Development Department � Phon •• �7-343- 4' 9 .i,
Development Services Fax: t I 343-7997 ,:t
On-Site Water & Wastewater Program O/ 4.ti
6 8 L 9 Si
,7� ite-Sewer/Well Permit Application
�i _ l _ 410 For A Single Family Dwelling
Parcel .
Property owner(s) MICHAEL ROURIK Day phone 907-306-6523
Mailing address 22607 NORTHWOODS DRIVE, CHUGIAK,AK 99567
Site address 22607 NORTHWOODS DRIVE, CHUGIAK,AK 99567
Legal description (Sub'd, Block& Lot ) NORTHWOODS; BLOCK 3, LOT 36
Legal description (Township, Section & Range)
Lot Size Sq.Ft. Number of Bedrooms 3
APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DEWELLING:
®all that apply) Initial I I Single Family(SF)
Absorption Field ❑ (w/wo ADU)
Septic Tank ® Upgrade M
Duplex (D) n
Renewal 1 J
Holding Tank ❑ Multiple Dwellings ❑
Privy ❑ (SF and/or D)
Private Well
Water Storage I
THIS APPLICATION INCLUDES A VARIANCE/WAIVER REQUEST FOR:
NONE Distance: -
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal codes.
GARNESS ENGINEERING GROUP,Ltd.
(Signature of property owner or authorized agent)
Permit/Rush Fees: $ S'OD Waiver Fees:
Date of Payment: 113) R OF) Date of Payment:
Receipt Number:
c h 0 I7 CI Receipt Number:
Permit No. bSV)°1 1 7C Waiver No.
(Rev.01/11)
gics
1 Advance j Treatment /Stc r,
GARNESS ENGINEERING GROUP, Ltd Dealer
ENGINEERING SALES CONSULTING
June 28, 2019
Municipality of Anchorage
Development Service Department
On-Site Water&Wastewater Program
4700 Elmore Road
Anchorage, AK 99507
Ref: Proposed Septic Tank Upgrade for Northwoods S/D; Block 3, Lot 36
To whom it may concern:
The referenced property is served by public water and a private septic system. We have been retained
by CRW Engineering Group (contract engineers on this project for the Alaska Native Tribal Health
Consortium), to evaluate the septic system on this property and prepare a design package for
necessary upgrades/repairs. The existing septic system consists of a 1,250-gallon steel STEP tank
and dual 5-wide pressurized trench type drainfields that were installed in 1994. We recently performed
a septic adequacy test and determined the absorption capacity to exceed 450 gpd.
Due to the age of the STEP tank (almost 25 years old) and our field observation that the tank looked
badly corroded, we are proposing to replace the tank with a new one. Attached is a design drawing
showing the proposed location. We are proposing that the old STEP tank be completely
decommissioned per UPC and two new Infiltrator tanks be installed, an IM-1060 2-compartment
Infiltrator tank and IM-540 Infiltrator pump tank. Based upon our site evaluation, the soil cover over the
new Infiltrator tank/s will be very close to four (4) feet deep. We are proposing the contractor expose
the sewer line where it exits the house to determine if proposed Infiltrator plastic tanks can be installed
without exceeding 4 feet of soil cover. If it is determined that the soil cover will exceed 4 feet, then the
tanks shall be installed in accordance with the attached detail drawing "Infiltrator IM-Tank Installation
Requirements for Increased Backfill Depth—6 FT Max. —Alaska Only".
We believe that the pressurized line from the existing STEP is compromised to some extent; therefore,
we are proposing to install a new pressure line from the STEP tank to the existing trenches. We are
also calling for flushing valves to be installed at the end of each pressurized line (in the trenches), so
that the lines can be properly flushed/cleaned on an as needed basis.
We are unaware any adverse impacts this installation would have on adjacent wells or septic
systems. If yi u av any questions, please contact us at 337-6179. Thank you for your assistance.
Since -ly,l
-efFre� •. � -m ess, r.E., M.S.
Presl'- t
3701 East Tudor Road,Suite 101 *Anchorage,Alaska 99507-1259
Phone: (907)337-6179*Fax: (907)338-3246*Website: www.garnessengineering.com
/- I
—
• /
GEG,Ltd.HAS AN 8 PAGE SPECIFICATION LETTER INSTALL FLUSHING VALVES ON EACH
THAT PERTAINS TO THIS DESIGN.BY PROCEEDING END OF DRAINFIELD FOR FLUSHING ,
FORWARD WITH THIS INSTALLATION,THE DISTRIBUTION LINES(SEE NOTES)
ENGINEER,CONTRACTOR AND PROPERTY
OWNER AGREE THAT THEY HAVE READ THESE
SPECIFICATIONS AND AGREE TO ACCEPT THE •
TERMS AND CONDITIONS OUTLINED. MT21 ' MT4G•1
I I 1 N
INSTALL NEW 1.5"PRESSURIZED I , j
SEWER LINE FROM NEW PUMP TANK ' i I I EXISTING PRESSURIZED
TO DRAINFIELD(SEE NOTES)
i i 1 DRAINFIELD.PASSED
i ' ADEQUACY TEST ON 5/14/2019. SCALE:
ii
1 ` 1 SEVERAL MONITORING TUBES 1"=30'
SEPTIC INSTALLATION NOTES: 1 ` ARE CRACKED,BROKE,OR FULL
1.THE CONTRACTOR SHALL EXPOSE THE SEWER LINE 1 1 ' i OF DEBRIS.CONTRACTOR SHALL •
EXITING THE FOUNDATION AND DETERMINE THE
1 REPAIR AND FIXES ALL NOTE:ALL ADJACENT
ELEVATION.ONCE ELEVATION IS ESTABLISHED,THE 1 1 1 MONITORING TUBE AND MAKE PROPERTIES ARE SERVED
CONTRACTOR SHALL VERIFY THAT 4 FOOT MAXIMUM
BURIAL FOR INFILTRATOR TANKS WILL NOT BE 1 1 1 SURE THEY ARE SET TO THE BY AWWU WATER.
EXCEEDED OR IF THE AREA CAN BE GRADED SO 1 1 I DOCUMENTED ELEVATION
MAXIMUM BURIAL DEPTH WON'T BE EXCEEDED.IF IT IS ' SHOWN ON THE 1994 S&S ENG. NOTE CONTRACTOR TO
FOUND THAT THE INFILTRATOR PLASTIC TANKS WILL 1 RECORD DRAWINGS RESTORE ALL DISTURBED
EXCEED THE 4 FOOT MAXIMUM BURIAL DEPTH OVER 1 I SURFACE,FENCING,ETC-
TOP OF THE TANK/S,THEN THE ATTACHED DETAIL ' 1 TO PRE-CONSTRUCTION
DRAWING,FOR"INFILTRATOR IM-TANK INSTALLATION _S�MT1 `�MT3 CONDITIONS.
REQUIREMENTS FOR INCREASED BACKFILL DEPTH-6 c
APPROXIMATE LOCATION OF FENCE
FT MAX.-ALASKA ONLY"SHALL BE USED FOR THIS
INSTALLATION.
2.A NEW PRESSURIZED SEWER LINE SHALL BE
INSTALLED FROM THE NEW PUMP TANK TO THE j�4 AIIIUII• o . .
•
EXISTING DRAINFIELDS.PRIOR TO THE NEW
CONNECTION TO THE DRAINFIELD.THE FLUSHING SFS
VALVES ARE TO BE INSTALLED AND THE DISTRIBUTION EXISTING -WATER LINE ENTERS
•
LINES ARE TO BE FLUSHED/CLEANED BY A 3 BEDROOM •!...:••;.. HOUSE APPROXIMATELY
PROFESSIONAL SEWER SERVICE COMPANY.UPON
COMPLETION OF CLEANING,THE NEW PRESSURIZED HOUSE ��. ::4 HERE PER OWNER.THE
SEWER LINE SHALL BE CONNECTED TO THE `_,•;stiff CONTRACTOR SHALL
DRAINFIELDS.SEE DETAIL DRAWING ON PAGE 2 OF 2 o- HAVE THE WATER
FOR FLUSHING VALVE DETAIL. ....:,•:: :•.".
.�'W. SERVICE LINE
4 .'' `•.`.•- j: .�.• 1 SHED PROFESSIONALLY
3.THE NEW 1.5"PRESSURIZED SEWER LINE SHALL BE U .T.!•,•.', '!.� LOCATED PRIOR TO
HDPE AND MUST BE INSTALLED SO THAT IT WILL 0 1
,...; '•
'�
•.-••••• CONSTRUCTION.
COMPLETELY DRAIN AFTER EACH PUMP CYCLE.THE :• ':- •+w
LINE SHALL BE BEDDED AND MUST HAVE NO BELLIES.
THE SEWER LINE SHALL BE INSULATED WITH 4"BY 4' 0 #"�µ "I/ `� y:,.'+ r'
.7.P:7••:.;.1':'•••,.
WIDE OF RIGID INSULATION CENTERED OVER PIPE. / ,r EXISTING FOUNDATION
s. CLEANOUT(SEE NOTES)
EXISTING 1250 GALLON STEEL STEPr------------1t!:7-'>:-14.1\
I:, r
TANK TO BE DECOMMISSIONED PER UPC I ' .i•J Q-r,
cs ; 1 I :?w;-: ,
I I f
1 • f 1n— .:
PROPOSED 2-COMPARTMENT IM-1060I
+ i �;a..•,y: ASSUMED
INFILTRATOR SEPTIC TANK FOLLOWED BY A i :•'r is , LOCATION OF
IM-540 INFILTRATOR PUMP TANK.SEE NOTES 1 •'•••ro'' •'! WATER LINE
AND DETAIL DRAWING ON PAGE 2 OF 2 0
A •
PPROXIMATE LOCATION OF GAS LINE. �•i
THE CONTRACTOR SHALL HAVE THEI ••`.:•:.1, .t:, I KEY BOX
15 UTILITY EASEMENT
GAS LINE TO BE PROFESSIONALLY 1,'<:::5:::.-. 4.
LOCATED PRIOR TO CONSTRUCTION. '
APPROXIMATE LOCATION OF
ABANDONED 1981 DRAINFIELD
NORTHWOODS DRIVE APPROXIMATE LOCATION OF TEST
HOLE EXCAVATED BY ANTHC(2018.
SUS 14_4
*•" *•0
GARNESS ENGINEERING GROUP, Ltd' ; 4' . •
;
CIVIL& ENVIRONMENTAL ENGINEERS ��,. ....� • • f 0
3701 E.TUDOR ROAD,SUITE 101•ANCHORAGE.AK 99507"PHONE(907)337-6179'FAX(907)338-3246'WEBSITE:www.gamesseng ineering.com
PREPARED FOR: PHONE NUMBER: PAGE NUMBER: 0 e•I a '. Gar,-ss :•1-
CRW ENGINEERING GROUP, LLC 907-562-3252 1 OF 2 ����,'�.� CE- 3 •��
PROJECT/LEGAL DESCRIPTION: DRAWN BY: ♦ .. ... ............................
. ��' •` Z g ��.•'��:�
NORTHWOODS S/D; BLOCK 3, LOT 36 J.L.M. •,�0 �•• • _.1P, •
TYPE OF WORK: DATE: LICENSE ,01 ESS1..�.�
DESIGN OF SEPTIC TANK UPGRADE 6/28/2019 #AECC884 11����
Cp._..........}(.........--::-- $
.61W0,.*
GRADE TO DR.AI i 4 i
, / / // / / / ( / / / / / // / / \\ ,FINISH GROUND)
/ / / / / / / / / / / '
iV1'i/'
/ /// // // // / �// // / // / / // , / / NATIVE // / /////\/
/�\// / / /// / / // // / / /// 3;%CKFILL // /�\�/
/
// / / / / /
/\\ / // // // // Q/;,/,� // // // � ,- // // / , / NIAX
\//\ ��/rt l 1- I I I I I / //
�/ / / I I IJ / /
N •' 1 .1 Q GEOFOAM ��h V/ //
�•/ / I I ) I �/ /
/ / I I I 1 I I I ,/
♦�0. ..�
.,. -.•! --- ; - •: '• I ( ..• 4.- ..: .-1 : .. --. //,
••i . il .i • .-....,..ik ///
i'.0 • \� ., '."';;S TYPE 2A
_ /\��\
\/ \
1 ) ! . ..A C)44 .. N...... ,N, `-‘,.....
''. 749th..-r\ ••4(6
VO/y//M S �^ _ _ TANK
p: 11.... JOHN JOHN REESE LEAVITT• a `- INSTALL ON NATIVE - LEAVITT JOB 018015 002
jI SOIL BASE PER
co �f,, NQ.CE 9217 •�C7, IM-SERIES INSTALLATION LEAVITT&ASSOCIATES
9f• .• • • •• a. INSTRUCTIONS ENGINEERS,INC.
gF °pROFEssw�'� IIILK entuonATAL-CIVIL
s SURVEYING
w
I-
I-
NOTES: 41116,1111rilaTIIIIIITMOUT14,11AUP4 SAND NM
n044E(20WM- 1-71170 FM(20048341040
1-GEOFOAM(OR EQUIVALENT)2 FT MIN.
° 2-GEOFOAM TO EXTEND 1 FT BEYOND EDGE OF TANK ALL SIDES. if
w 3-BACKFILL SIDES OF TANK WITH No 57 STONE OR EQUAL(3"MINUS TYPE 2A
INFILTRATOR
Z OR ROAD BASE MATERIAL)
4-6"MIN FILL OVER THE TANK(FOR GEOFOAM BASE) INFILTRATOR WATER TECHNOLOGIES
U 5-
WATER TABLE SHALL NOT EXCEED THE OUTLET PIPE INVERT ELEVATION4 Bootless Parc Rd T Crook.CT 06475
• 6-CC FILTER FABRIC SHALL BE AS APPROVED CURRENTLY BY HEALTH DEPARTMENT. (RD)OlddS4J6
O 7-COMPACT BACKFILL IN 1FT LIFTS(MAX)WITH HAND VIBRATORY EQUIPMENT
OR EQUIVALENT INFILTRATOR IM-TANKS
CC 8- THERE SHALL BE NO VEHICULAR TRAFFIC OR SIGNIFICANT LIVE LOADS
Q (LAWN TRACTORS ACCEPTABLE) INSTALLATION REQUIREMENTS
U 9-GEOFOAM SHALL HAVE CLEAN,NEAT CUTS AROUND THE RISER(S)OR STAND PIPE FOR INCREASED BACKFILL DEPTH
2
10-BACKFILL TO GRADE WITH SUITABLE FILL.SLIGHTLY MOUND FINAL GRADE TO SHED SURFACE 6 FT MAX.COVER -ALASKA ONLY-
o DRAINAGE AWAY FROM THE TANK EXCAVATION AREA Down E AN GaIR 09/07/2018
11-GEOFOAM SPECIFICATION TO MEET OR EXCEED ATTACHED SPECIFICATION(INSULFOAM 40/60)
!dc -•-=amid Cy !!rt 1 of 1
O
Win. 4
NiINNTECHNICAL
DSImo=
� SPECIFICATIONS
"/ WE PUT WATER IN ITS PLACE
107BC
Series: Standard Series
Material: HDPE
Box Color: Black
Lid Color: Green
Lid Marking: ICV
(Irrigation Control Valve)
Box Weight: 1.04 lbs
Lid Weight: 0.23 lbs
Total Weight: 1.27 lbs
Load rating:
Pedestrian & lawn care equipment
MADE IN THE USA
B
A "
,r'
i_flstii {
A
- D Mouse hole:
Irv'' • 2 3/8"x 2 3/8" E
B
Box Dimensions
Lid Dimensions A.Top inside diameter 5 7/8"
A.Top diameter 6 1/2" B.Top outside diameter 6 3/8"
i
B.Bottom diameter 5 3/4" C.Bottom inside diameter 71/2" �'
C.Rim thickness 3/16" D.Bottom outside diameter 8 3/8"
D.Overall height 3/4" 8 7/8" C
E. Height
D
Li N.Harvard A�cnue /A„ "
Lind.a).CA 93217
wit visit ndspro.com for specs, "mil INN 1:0
800-726-1991 ` detail drawings,and case studies wigI/ WE PUT WATER IN ITS PLACE
•
•
Northern Comrnunities ‘....1i , (p Municipality of Anchorage
Jr
WI ill
/ V T 3733 ea
r`' ,� sol 3118 i
/VIWit.,
3138 •
.ti
Pipe Types
.. '9 ABS Acrybro8 m-8 o.oa-Styrene
• - AC Asbestos Concrete
CC Concrete Cylinder
801 j CI Cast Iron
CIPP Cured In Place Pipe
CMP Competed Metal
tr.
CN Concrete
CU Copper
't' • a Due to Iron
FC Famed Concrete
IGI Galvanized Iron
Huh Density PoNethylene
1� 101 MLCE Mortarned Concrete
• _ PE Pdydryprw
PVC Pofyvinylchbridc
3733 001 RC Reinforced Concrete
ST Steal
TC Iodate
E• E LINK Unknown
VC Verified Clay
WS Wood Stave
Legend WELL HOUSE. Q WST Welded Sall
MCKINLEY UTIUTIES(OTHER UTILITY) Y 0 NP No Print
..r... ...�.�... :.��...�. - \ • PrNat•System
■� N
: W.
•...... fi 1 A
liy _ 801 he
4...M ea 300 800
0 .......... V • • • F•N
43..e..+•�N, .fit'. 't 22180 0 Mop Created 10/03/2018
•r..« Mcklnley Ut11MI•Y m_ '
r.... (Other Water N
0110T) y rV cV
^�,^f A Legal:
..
<.. ...... raw. . F g; .4 h
SE 1I4 Sec 4 T15N R1 W
—..mm4 n.o.o a.A.., f fd
—......ms twos .....�' :� S i.'1/i 1.ln;f74�—:N TS IOT .V i+ nr.t 10a ..nYY {'•
NINO MP
am
-.N....r+......w..w -'.. - �••�r�-• MCKINLEY UTILITIES ''
0) ,0 1;5%K 1,:,,,s VA I,,ro X1T ISrN1s.
_ _ _ ^- PLAN SET 8398 ti
•FpWA*ION ANO pATA CONTAINED ON TIr•00CY•M1R
' tea iasti 1-1 41 �� I(,U NY tt<
• NOT TO r COM•O[RIO ACCURATR MO TNI W„ Nrd y ♦ •a 'f• w • 1201 • .e •y
MUNICIPALITY OF ANCNORAO4 AMMO*NO BARRY `�
FOR OAMAOee 00C UMW AS A MOW O/04010
TO UOCUMtAT FOR TO LAOS AAO MOST Ur TO°ATI -.4n,e 0 N.N.S. 13280 13281 1 y
N1'OIWATq. YOU ARE 0500D TO DMA TO N _� y
O� t
ANCHOAAO0 VOTER A WVTeWain UTILITY 520 V EKLUTNA P2 STATION 7 IT' - `�
+' OM'KM ORM eTMTNO O►RATIOIM. _• i HOMESTEAD VAULT ,t
NW1459 Grid Number Water Distribution System I �„ {,... ,,y �,,�,� ,,�,
(c/
MUNICIPALITY OF ANCHORAGE
WATER CONNECTION — Location Record ACCT. NO. V' 7 ;(-- C7
l
•
NAME ADDRESS c2 (p O 7 W OC�,msto d S D (
LOT 3to BLOCK 3 ADDITION 11/erotklidetds Sy b
SIZE CONN. DATE MADE NEW CONN. REPLACEMENT CONN.
LOCATION: ALLEY El STREET El TYPE OF MAIN { ) SHOW SKETCH ON REVERSE SIDE
CORP STOP THAW PLATE PERMIT NO.
CURB STOP C TO C KEARNY WIRE CONNECTOR W.
CURB STOP C TO I OTHER: CONN.
CORP CONNECTOR INSP.
COUPLING C TO I PERMIT
X BRASS BUSHING TOTAL
X GALVANIZED BUSHING COMMENTS: BROKEN MAIN, EXT. CONNECTION. EXTRA PIPE
2 PART UNION CASING, DELAYS, ETC. FT. @
3 PART UNION PILA
SERVICE CLAMP X ❑ PAID PREY.
COPPER PIPE 0 W.M. #
1 1/4" KEY BOX ❑ PAID CASH
2" KEY BOX El SUB AGREEMENT
THAW WIRE DISCONNECTS ALT. #
LOCATION ,c' W o4 E. et- EXCAVATOR ❑ IMP. DIST.
O-1 $ APPOINTMENT TIME: #
TIME READY: El EXT. AGREEMENT
CONNECTION MADE BY INSPECTED BY /-404, �m �eT #
7• "CO ♦1.1,9-,♦
KEY BOX AND SERVICE LINE LOCATION BY SKETCH
INDICATE
NORTH
STREET ALLEY
_
Kei
D
15-1
31-058 (12/77)
N 33 WATER:::::2::
\ s s u. _
f S 2:02,......7...., ATIOMIAS
Iu 2.•nn c04"tc�c. o a o coNrtrlwnN LATtli.
i
'•.; k I3 LK 3 F I!_ �t�'t SPECIFICATIONS.ANCNOWE 9iANOM05
,j. 5 A FIRE X1'MANT LOG.TN)t15 MULL S%r'%••
•o TEE FOR fIRVRE MTp4NT INSTALLATNMI�•e
.21
'b (• x I Q to➢fD.LKtrlie{ ul1 `�ilsl b ime
4 2 3 1 j \ >r.w.nw axes"!the.mow.),to fir*
R ,, .r /N� a(RN 1a10.!....E..N
I; m ZA LOG e`.... m T�4.t M: 1 , n t.eIu r..soe.LTwµy a u...x,..cer to
Ntiro iwaeu of.0*Os osa.y,r wiTn.o S
-1014c soNtr61.1,,,
�. Id Ti)•3 Lf B DIP CAST w,+ f ma S Nekti Al:NUR N R.G.S.19!41: o
• \ `9. u [[r.Irorm do.Ire.4rL puss,.
NORTHWOODS DR
lc I •La auaurawa..w'tN.... aime.a.
. / I:f 14 I IZl•Lam` ' u 6
I _ \ tbwDY.E.fa.i Uw'tot" m.v..•11�
•tH y V f ucTW utsn y.ta Y to to,!sots.after toot
_ +--_. � masa �_�I��
__— — -- ° - MEM
iem�eo —��--_` —tti —��■ ��. �ri -y---=s�: a�t+�te�s
__ ___= =»>x� . —psi- - - .,.. , ._
ifoiIciic-=ii'gmciESiii®®i i�seEE�a;�®Imi:= =-� �1"-� is-i=�
____ c=s -iso_-11 s -- r .MEE:1561M h— • A
- e -m- --- -- = -.-
mm � m=ii� = � a-a-= � , - -- m=
_ ®- osi wsp-� = � ®® =i =-` Vi-i®®�104- G�lN-� isma-M '�099�= NG �-
- 0 1
� � ristim-ms
M- m� _ i -.
_® Eimii -.Eel �wsi�® lG�m.s�-� ® !®m-m- iirm®ms
-- = i_ ® ® _i i .
mm =imaim iiilmil !�- iiii -
MEE
- = = __ __
gi.
ii_
L
- _ 3 _E cic=i:_= c ===-
:. .. 81.00 82.00 83.00 84400 85.00 86.00 87.00 88.00 89.00 90.00 91.00
• _ ti AS - BUILT \ BI_K 4 A.
BLIt 3 k I 2GRA•tG 6
J��
I
33 28 •
• 23 , i _ ��/ 1
IQ 1,07007 Li B GIP N WOO osE l 1 ;
:I-:I:
NORTHWOODS } ' IDR BE$;a�L/ r ii
• 1rj ' 1, '.kA. 1"�If E%.6 f^1 zAErre Fy I 4 i •�.K'
L ! , 11P>1l I ..y .- BLK _0• •2
1 'b •
:.....:-_:. .:77.--.. 'EL': .... �; � c= 447._
� _-.--_.. -?i- I . mc.=�-= -- �-- :mac�eI. i - ��� ' I.,...iiiii___0_,Iiiii -` 1-MMiiGiliceii =i- °c iA=.TI - - ��- 1 1 _ _ —M__ --_ i l• NI' I •INS _i_ c i�� limmi a11i
-— -% is cMEsn '4ii'g--111!."747-0.4:1216":-E!!-M" -- cE_c� - - e�ceiaItTi h■
mum IM=
c-m1-_ i-If ®i-� ----'�i� —�-��tiail .4! :ttg_41R -_ inti ',r
1,.. . .._ , .
.- - .. .. .= • i .--mii - --Eta'�a'-�1 ii-- -ii-ii�� i
_ tim-I . =--• ----===.,-- IESINISIBE==.= ==========Eio-aZM- : ==r.- 7_.-- -:_.,--..,===n-zt.--====;.••== =___ -
•
-.7..... i- i�iiil•1•iiiM®iiiliiiMIIMM�IRi�IMI = ���M ■� _ 7�T-'
_ __--_-__ - =.1— ---iri-_ -1- - 11Iiiii - -. ' �,
tai- -li--------:--ii -------y�--os--.--- -'----i1---i U ___
_--•= =_ —_—_=' --- ----W- C7�••� -----._.:..._... ' _.. . too.- „o , li• iv"tt • .•
•_•• • 0. ••..• ..11 •_-_•• •N�•,• •.• .•.• •: •. •.-�• ,•••.,1,• ..._ • .•.• •l •••
GRAPHIC-�■.. ____ _- SCALE NORTHWOODS SUBDI\
•
RA MOO •I. DAR • 00E0VII006 R TM NO. • 1.0E 110N NO. LOC.°. KIM. RATA .nog. 011U Contracting Engineers
_ —L l ri- i WATER DISTRIBUTION 5.
C•-. :«•R�.2,#��rt .a?l1^1��'3a7C1������ arid Aeeociatce
rII tSOg.IICCt)-SUPYeyt/r• ' NORTHWOODS DP
IICTIWi RECORD REVISIONS 2711-3771
©1 I• ■ l'®.1-��� 2i2 E..Inr.mal At•an Roam /IW.r-a•DAT•ATTL:q•IF•gANC(0.1)
CAL DATUM VRITICAL DATUM RAN CHECK netEo.r AI•tL. 99502 \•sEAL' SCALEVq I•.17,,,7,Na 7•-S
/ INSTALL"FLOWER POT" EXISTING U
INFILTRATOR TANK NOTES: STYLE COVER OVER GRADE
STANDARD TANK CONFIGURATION • PER INFILTRATOR SYSTEMS, INC., THESE TANKS HAVE A FLUSHING VALVE J
IM-1060 IM-540 MAXIMUM BURIAL DEPTH OF 48 INCHES OVER TOP OF TANK. >� * * t * 4 D
TO • TAL CAPACITY 1287 GALLONS 552 GALLONS PER INFILTRATOR SYSTEMS, INC., THE TANKS ARE TO BE O
WORKING CAPACITY 1060 GALLONS 475 GALLONS
LENGTH 127" 64.9" BURIED SO THAT THE INVERT OF THE OUTLET OF THE IM-1060 AND —INSTALL 1-1/4"TO 3/4"SCH. 0
WIDTH 62.2" 61.7" THE INLET OF THE IM-540 INFILTRATOR TANKS ARE NOT SUBMERGED40 PVC MALE THREADED
HEIGHT 54,7" 54,6" TAI
INLET INVERT 47" 44" DURING HIGH GROUNDWATER CONDITIONS. • FITTING(FOR ATTACHING Z
OUTLET INVERT 44" N/A • IF GROUNDWATER IS ENCOUNTERED, THE CONTRACTOR SHALL :I GARDEN HOSE) E
OVERRIDE FLOAT N/A 42" CONTACT THE ENGINEER TO EVALUATE IF THE EXISTING SOIL COVER LuHIGH WATER ALARM N/A 40"
ON/OFF FLOAT N/A 28" IS ADEQUATE TO RESIST BUOYANCY FORCES, OR IF ADDITIONAL REMOVE AND INSTALL 1-1/4"SCH.40 PVC Z Lo
NOTE:FLOAT LEVELS ARE FROM BOTTOM OF PUMP. BALLASTING WILL BE NECESSARY TO OVERCOME BUOYANCY FORCES. REPLACE EXISTING (9 N
BALL VALVE(NORMALLY CLOSED) ii(. CT)
THE CONTRACTOR SHALL INSURE THAT SOIL COVER AND/OR INSULATION cc O W m N w o
BALLASTING IS PROVIDED AS OUTLINED IN THE INFILTRATOR"SEPTIC AND FILTER INSTALL 1-1/4" o f Lo m N > N
TANK BUOYANCY CONTROL GUIDANCE" BROCHURE. FABRIC AS SCH.40 PVC cc cr Z~ z 0 z J co
REQUIRED TO VERTICAL PIPE a 0 z rn w(N 3 ,ii(
INSTALL NEW w i a a a
—INSTALL 1-1/4"
FLUSHING VALVESSWEEPING 90CFFITTING
C a a a o 0
SJE RHOMBUS INSTALLER FRIENDLY
SJE RHOMBUS MYSPY MESSENGER SERIES(IFS)TIMED CONTROL PANEL EXISTING 1-1/4" $
UNIT/INTERIOR ALARM(OR EQUAL). 11 . WITH DRY CONTACTS FOR INTERIOR PRESSURIZED
TO BE INSTALL INSIDE RESIDENCE. ALARM OR EQUAL.INSTALLED ON DISTRIBUTION LINE c
EXTERIOR OF HOUSE.
INSTALL BURIED AND ABOVE GROUND
WIRING FROM PUMP TANK TO CONTROL �U�U� `��i .01., ��.�� . ��• , '' Z
PANEL PER MOA AND NEC REQUIREMENTS. a.a.�' ��x, �� .�� .�� �� ,'� .�� Q
I-
FINAL GRADE(SEE NOTE) '� �� �� ^� ^� �� ^� �� �� .� .� �� m O
24"INSULATED LID • -•-•-•••MitA •• W 0
24"RISER.TOP 4 FEET ���*�•W.�•�•�.�•OP•�•'O�� 3
INSULATED WITH SIM/TECH PRESSURE FILTER .�We.We..ps.^s.^s ;�.�ca.;••.;••.^s..•s. Z
4.•••••
• • • • • • • • • • • i
4INCHESOFINSULATIONAND 24"RISER.TOP4FEET '�Or�Ow�OP'�0•'�OP"OOP0MalOP'.OP'�Val�'� F -JLID INSULATED WITH 4 INCHES. 4"CLEANOUT INSULATED WITH �� ;f �� �. �. ;. �� '. �e �� ►. �� ' h JLI2 INCHES OF INSULATION QUICK r-.-.•.-.-.-.-.-.-.-.-.4. Z
DISCONNECT "-A�...I'.It.�:����v� .����"��'�, /.", ~J Z 0
DBL1 DBL2 UNION �, �+ OZe e FLUSHING VALVE DETAIL DRAWING �/ D
1�1tu- Y
::•:;•k: Ia Lu1' W4 -
-J
14a' ~
4"BY 4'WIDE RIGID Z C7 a co
• !.:ii:: INSULATION CENTERED
2"OF INSULATION _81'I-+ P:::: Z 1- D
OVER TANKS - > OVER PIPES �� 00 w 0
0
'48"MAXIMUM = ' :: W': p•j Z
PVC CONDUIT - �'? Z `1 Q
•
FOR ELECTRICAL 1.: INSTALL STAINLESS STEEL BARBED FITTING FOR PVC TO HDPE PIPE TRANSITION. N Z C7 g 0
Y
!• CONNECTIONS I ! : Z o O Z
(FLOATS&PUMP) '': ,,:oneems,w w W v
1` e°f a�"d°°m�--1.5"HDPE SUPPLY LINE TO DRAINFIELD.SUPPLY LINE SHALL BE SLOPED TO m• U
�i ,:ii O
1'' 1 DRAIN BACK TO PUMP TANK AFTER PUMP CYCLE.CONTRACTOR SHALL C o 0 Cfsi d
gromr�eareme.i ).romr�������aromagoo o��u?gmym 6 1 °o�� ""¢D�. "�< 4-� �swer,o a INSTALL AND BED SUPPLY LINE SO THERE ARE NO BELLIES IN SUPPLY LINE. w
INLET I II `� F�
-- 4 4IIM OUTLET la I �j o p O
' r‘allWEEP HOLE 11��--�� g cc_ cc J
I' 'TIMER OVERRIDE FLOAT (42") o LI
~ MI~ 0w w0-
475 GALLONS CAPACITY S oO o CC
,?, Q Z w CL
OPERATING " C 3� `�, WHEN FLOAT IS ACTIVATED. 'FLOAT NOTE: MEASUREMENT IS WHERE FLOAT wLIQUID LEVEL • ��- WIRE ATTACHES TO PIPING WITH A 3.5 INCH J(1,094 GALLONS) 'HIGH WATER FLOAT(40") MINIMUM TETHER FROM PIPING TO FLOAT.ALL �����` ! 455 GALLONS CAPACITYFLOATS MUST BE NARROW ANGLE FLOAT . �4• F 11,E. v— , ,, WHEN FLOAT IS ACTIVATED. (SEE FLOAT INSTALLATION INSTRUCTIONS) .'P� 0 • ,./
\`��','j ,
'LOW LEVEL CUTOFF NOTE:ALL PRESSURIZED PIPES ARE TO BE ' •
FLOAT(ON/OFF)-(28") SCHEDULE 40 PVC UNLESS NOTED OTHERWISE. so . I ¢• 1\ * #
10 :-261 GALLONS CAPACITY "' j
IM-1060 GALLON WHEN FLOAT IS DEACTIVATED. •
2-COMPARTMENT IM-540 GALLON SINGLE • • •'�
INFILTRATOR TANK COMPARTMENT INFILTRATOR Q i i-y '. SS ✓ i
TANK WITH INFILTRATOR GOULDS PE51 M PUMP OR EQUIVALENT ���' CE- •795 �'
PIPE ADAPTER RING 1
2-CINDER BLOCKS-SIDE BY SIDE-FOR •♦•AF0.p X017:. ,� P\,"4,--
'IN •
PUMP STAND(SUPPLIED BY CONTRACTOR) I N ,ROFESS\�4.
LICENSE 1j„"�
#AECC884
Duwmffa.Nlt EAST 100.00
I
• •
L.J V I
•
•
1XCK War __►
949 t
o
SINGLE FAMILY o
LcP FRAME HOUSE —"--.
L4
----'- i 1CANL �,5.�
._......._ 1CANL............. 9E '.ocr.t7CNJf....�..._.._: Y'"
s
L [.._._ WA(KWAY
•
•
1S'UTILITY EASEMENT
EAST 10000
NOR THWOODS DRIVE
0��0000pp�
�e_ OFA •
oo�P
49 T TH %1\
.
S-140Qi$4l j AS—BUILT SURVEY 1 " = 20 '
•
i ` NO CORNERS SET THIS DATE
o�ai°, SHANE A. HOLT •
�Q�
Q •
LS-6914 0` I HEREBY CERTIFY THAT I HAVE PERFORMED A SURVEY
�4ap �a4 OF THE FOLLOWING DESCRIBED PROPERTY
r°fessiona‘ vQo
�ppO�bpo LOT 36, BLOCK 3, NORTHWOODS SUB.
ANCHORAGE RECORDING DISTRICT, ALASKA, AND THAT THE
VISIBLE IMPROVEMENTS SITUATED THEREON ARE WITHIN
THE PROPERTY LINES AND NO VISIBLE ENCROACHMENTS
THE INFORMATION HEREON IS FOR THE USE OF LENDING INSTITUTIONS SPECIFICALLY TO SHOW ANY EXIST OTHER THAN NOTED.
CONFLICTS BETWEEN EXISTING STRUCTURES AND PLATTED LOT LINES AND/OR EASEMENTS; AND IS DATED AT ANCHORAGE,ALASKA THIS 1ST DAY OF
NOT TO BE USED FOR POSITIONING ADDITIONAL STRUCTURES, IMPROVEMENTS, OR FENCELINES.
EASEMENTS OF RECORD, OTHER THAN THOSE APPEARING ON THE RECORD PLAT , ARE NOT SHOWN
HEREON ( UNLESS INDICATED) MAY 2019
NOTE: FENCELINES THAT MAY APPEAR ON THIS DRAWING ARE NOT TO BE USED TO DETERMNE
PROPERTY LINES OR POSITION ADDITIONAL IMPROVEMENTS. HOLT LAND SURVEYING
ANY PAVING SHOWN HEREON MAY BE APPROXIMATE DUE TO EXCESSIVE SNOW AND/OR ICE. 9309 GROVER DRIVE
ANCHORAGE,AK 99507
14214,FB 196-25 345-5513
Municipality of Anchorage Page
DEPARTMENT OF HEALTH AND HUMAN SERVICES
ENVIRONMENTAL SERVICES DIVISION "
P.O, Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744
On-Site Wastewater Disposal System and/or Well Inspection Report
Permit Number: ~lgR~O~O PID Number:
Name:
~-4&'p-/~z-~ C~O-z~J /~c~ Wastewater System: D New D Upgrade
Address:
zz~o7 ~T~W~ D~. ABSORPTION FIELD
~h~n~: ~ No. of Bedrooms:
~o~/~,~ q~77, ~ ~Deepmrench ~Shallowmrench ~Bed ~Mound ~Other
LEGAL DESCRIPTION so, Rating: Total Depth from original grade:
~.~ GPD/Sq. Ft.
Lot: Block: Subdiv~ion: Depth to pipe bosom from original grade: Gravel depth beneath pipe
Township: ~ Range:_ Section: Fill added above original grade: Gravel length:
I
/.~ Ft. /~ Ft.
WELL: ~ New ~ Upgrade Gravelwidth: Numberoflines: Distancebe~eenlines:
~ Ft. ~ I / 0 Ft.
Classification (Private, A,B,C): ~l~ Total Depth: Cased To: Total absorption area: Pipe material:
Driller: Date Drilled: StaticWaterLevel: Installer: Date installed:
Yield: GPM J Pump Set at: Ft. Casing Height Above Ground:Ft. TANK
I
SEPARATION DISTANCES ~ Septic ~ Holding ~S.T.E.P.
To Septic Absorption Lift Ho[ding ~ublic/Private Manufacturer: Capacity in gallons:
From Tank Field Station Tank Sewer Lines ~~ ~
Waif 2¢0 I& ~ ~ ~00 I~ ~ ~ ~ Material:~ Number of Compadments:
Su,.ce ' ' LIFT STATION
Water /~ /~ ~ /~ ~
Lot Size in gallons: ~ Man~cturer:
Line ~' /~ ' ~ / ~ /~~ ~~
, "Pump on" level at: ~ "Pump off" leve~ at: High water alarm at:
Foundation /~ ' ~0' /~ ~ ~1~I ~" ~"
Cu~ain :Pump Make & Model ~ Electrical Inspections pedormed by:
Drain - ~0 ~ < ~ ~ ~ ~ ~] ~~ ~P~/~O~
Remarks: BENCH MARK
Location and Description:
Assumed Elevation:
E~[~'A SEA~
S & S ENGINEERING .~ ~..
17034 Eagle River Leop Road~ N~, ~ ~; .... ~.~,~:;~.¢.,,,~,,,~;
of Health, nd Hum~Services approval ~ ~; .....
Department
Reviewed and approved by '- Date:// ' '~z,.~e~."~- ~'C~?
72-013 (Rev. 9/91) MOA 25
Perm'it No.Sw94°58° Page 2 of 2
Municipality of Anchorage
DEPARTMENT OF HEALTH AND HUMAN SERVICES
ENVIRONMENTAL SERVICES DIVISION
P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744
On-Site Wastewater Disposal System and/or Well Inspection Report
Legal Descriptio~ORTH WOODS SUBD.; BLOCK 5, LOT 56 PIDNo.: 05175146
C01
1 ~o ~ GAL
~S.T.E.P.
::SYSTEM
C02
GRADE MT3&MT4)
MT
MT
!97.9'
MT 1 &MT2) 97.9 ..
(MT3~MT4)
,89.4' NO WATER FOUND
DRAINFIELDS
SCALE 1" = 40'
EXISTING
3 BDRM
HOUSE
1500 GAL.
I.T.~.P. SYSTEM
72-013 A (1/93)
A B C D
FCO 5.7 18.0 - -
CO1 i6.0 10.0 - -
C02 24.0 9.0 - -
MH 24.9 10.5 - -
M'$.1- ........................ 1.2,-7 .[4~5
MT2 69,7 70.7
MT3 25,0 15.2
MT4 71.4 69.8
N
;: A-PI,~$, NO~IE SERVICES From: "SPARROWS" ELECTRIC, INC., [O-~9-g~ l~l;§Oa~ p, Z of 2
PM: 344-5539
'i~E~EgQ~I_~[-~Q!~I¢;
7310 ~LEN DRIVE
FAX: 344-5538
October 19, 1994
TO: A-PLUS HOME SERVICES
RE: SEPTIC LIF'£ STATION WIRINC
LOCATION: PETERS CREEK
TO WHOM THIS MAV CONCERN: THE SEPTIC [.[FT STATTON ABOVE WAS
WIRED BY CERTIFTED ELECTRICAL CONTRACTOR AND BY CERTTFIED
JOURNEYMAN ELECTRICIANS,LICENSED IN THE STATE OF ALASKA_ THE
SYSTEM WAS WIRED IN STRICT ACCORDANCE WITH STATE , NATIONAL
AND LOCAL CODES,
PS: (IF THERE ARE ANY QUESTION~ CONCERNING ABOVE STATED PROJECT
PLEASE FEEL FREE TO CAI.I.)
PROFESSIONALLY YOURS:
(PRESIDENT)
PAGE 1 OF 1
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND HUMAN SERVICES
P.O. BOX 196650, 825 "L" STREET, ROOM 502
ANCHORAGE, ALASKA 99519-6650
ON-SITE WASTEWATER DISPOSAL SYSTEM (UPGR-~DE) PERMIT
PERMIT NUMBER:SW940380
DESIGN ENGINEER:S & S ENGINEERING
OWNER NAME:TIERCE GABRIELE OGDEN &
OWNER ADDRESS:22607 NORTHWOODS DR
DATE ISSUED:10/03/94
EXPIRATION DATE:10/03/95
PARCEL ID:05173146
LEGAL DESCRIPTION: NORTH WOODS BLK
3 LT 36
LOT SIZE: 20122 (SQ. FT.)
NI/MBER OF BEDROOMS: 3 THIS PERMIT: 3
THIS PERMIT IS FOR THE CONTRUCTION OF:
DISPOSAL FIELD /SEPTIC TANK SYSTEM
ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH:
1. THE ATTACHED APPROVED DESIGN.
2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS
15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL
REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80).
3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS
PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY
CALLING 343-4744 (24 HOURS)
4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL
ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING
WEATHER MUST BE EITHER:
A. OPENED AND CLOSED ON THE SAME DAY
B. COVERED, SEALED AND HEATED TO PREVENT FREEZING
5. THE FOLLOWING SPECIAL PROVISIONS.
SPECIAL PROVISIONS
RECEIVED BY: ~~
ISSUED BY:
//
DATE:
September ~ 1994
ROBERTSHAFER, P.E.
CIVIL ENGINEERS
(907) 694-2979
FAX 694-1211
HEALTH AUTHORITY
APPROVALS
SEWER & WATER
MAIN EXTENSIONS
SEWER & WATER
iNSPECTiON
ENGINEERING STUDIES
AND REPORTS
WELL INSPECTION
& FLOW TEST
SITE PLANS
ROAD DESIGN
SOIL TEST
PERCOLATION
TEST
STRUCTURAL&
MECHANICAL
INSPECTIONS
ON SITE
WASTE WATER
DISPOSAL SYSTEM
DESIGN
Municipality of Anchorage
DEPARTMENT OF HEALTH ANDHUMAN SERVICES
825 'L' Street
P.O. Box 196650
Anchorage, Alaska 99519-6650
REFERENCE: Lot 36; Block 3; Northwoods Subdivision
Request you issue a permit to replace the septic system serving the
three bedroomhouseonthe referenced property.
A test hole was excavated and a percolation test performed. The
approximate location of the test hole is located on the attached site
plan. The monitoring tube within the test hole has been checked and
found to be dry. Attached is the proposed upgrade design.
This property is served by a Con~uunity Water System.
We do not anticipate any adverse effects on neighboring properties by
the installation of the proposed septic system.
There are no protective well radii which encroach upon the property.
During an inspection of the existing septic system, effluent was found
to be surfacing in the area.
If you have any questions, or require additional information for your
review, please contact us.
Robert C. Cowan, P.E.
RCC/JA/gk
17034 NORTH EAGLE RIVER LOOP · SUITE 204 · EAGLE RIVER, ALASKA 99577
0
o~O
oo~
58'
Z
X
,.h
o8
':lCl¥~lOd n [ '
z
>->-
Municipality of Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L" Street, Anchorage, Alaska 99502-0650
SOILS LOG -- PERCOLATION TEST
PEREORMED EOR: ~"~t..F.E
1
2
3
4
5
6
7
8
9
10
11
12--
13
14
15
16
17
18
19
20
COMMENTS /'1,
DATE PERFORMED: ~
Township, Range, Section:
WAS GROUND WATER
ENCOUNTERED?
IF YES, AT WHAT
DEPTH?
Deptl~ to Water Alter ..:.....,,~/
Monitorino? ~lcy Date:
SLOPE SITE PLAN
Reading Date Gross Net Depth to Net
Time Time Water Drop
I1: ~o ~ ~.', ~"
PERCOLATION RATE __
TEST RUN BETWEEN .
(minutes/inch) PERC HOLE DIAMETER
FT AND ~ ' FT
PERFORMED BY: I CERTIFY THAT THIS TEST WAS PERFORMED IN
ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE:
72-008 (Rev. 4/85)
ROBERT SHAFER, P.E.
ON-SITE WASTEWATER DISPOSAL SYSTEM
CONSTRUCTION PRACTICES
and
MATERIAL SPECIFICATIONS
CIVIL ENGINEERS
(907) 694-2979
FAX 694-1211
HEALTH AUTHORITY
APPROVALS
SEWER & WATER
MAIN EXTENSIONS
SEWER & WATER
INSPECTION
ENGINEERING STUDIES
AND REPORTS
WELL INSPECTION
& FLOW TEST
SITE PLANS
ROAD DESIGN
SOIL TEST
PERCOLATION
TEST
STRUCTURAL&
MECHANICAL
INSPECTIONS
ON SITE
WASTE WATER
DISPOSAL SYSTEM
DESIGN
REFERENCE: Lot 36: Block 3; Northwoods Subdivision
GENERAL:
1. The scope of this project includes the installation
of two five foot wide drainfields and a 1250 gallon
septic tank effluent pumping (S.T.E.P.) system to
serve the existing three bedroom residence on the
referenced property. The existing pressure
distribution bed is to be abandoned in place. The
existing 1000 gallon septic tank and lift station
are to be excavated, pumped, crushed and abandoned
in place.
2. Construction shall be in accordance with the
approved site plan and design drawings, Municipal
permit with any special provisions or conditions,
and all applicable State and Municipal Wastewater
Disposal Regulations.
3. The contractor shall be responsible for obtaining
any necessary underground utility locates.
4. Unless specifically agreed otherwise, the property
owner shall be responsible for final grading areas
subsequently depressed from soil settling. On all
leachfield mound systems, the property owner shall
be responsible for ensuring a satisfactory
vegetation growth over the mounded area.
5. Contractors installing wastewater disposal systems
must be certified by the Municipal Health Department
for system installations. Owners installing their
own systems must also receive prior approval from
the Municipal Health Department.
SEPTIC TANK INSTALLATION:
1. A septic tank is to be constructed by a certified
septic tank manufacturer. Construction shall
include two 4" cleanouts for pumping access.
2. The septic tank shall be sufficiently bedded to
prevent settling or shifting of the tank.
17034 NORTH EAGLE RIVER LOOP · SUITE 204 ° EAGLE RIVER, ALASKA 99577
Page Two
Lot 36; Block 3; Northwoods Subdivision
September 14, 1994
3. Ail standpipes on the septic tank shall extend a minimum of
12 inches above final grade.
4. Septic tanks installed with less than 4' of cover shall be
insulated.
5. Final grading over the septic tank shall be such that a
positive slope exists away from the septic tank.
ABSORPTION TRENCH/DRAINFIELD INSTALLATION:
i. Excavate the proposed trench to the dimensions shown on the
design. The bottom of the excavation shall be within 2
inches of level. If the sidewalls of the excavation become
smeared, they must be raked or scratched (roughed-up)
before gravel (sewer rock) placement.
2. Once the gravel is installed, the distribution pipe is to
be installed level with the perforations faced downward.
Gravel is then to be placed over the distribution pipe to
provide a minimum of 2 inches of cover over the pipe.
3. A silt barrier must be installed between the final gravel
layer and the native soil backfill. Ensure the silt
barrier covers the entire gravel surface before placing
backfill.
4. Monitor tubes shall be of four (4) inch diameter and
installed approximately in the locations shown on the
design. The portion of the monitoring tube extending
through the gravel shall be perforated from the bottom of
the trench to the invert of the distribution pipe. This is
equivalent to the effective depth of the gravel as noted on
the design.
Page Three
Lot 36; Block 3; Northwoods Subdivision
September 14, 1994
5. Backfill over the final gravel layer must not be less than
twenty-four (24) inches. Insulation must be installed when
the backfill depth is less than thirty-six (36) inches.
The finish grade over the trench must be mounded to prevent
the formation of a depression after settling.
MINIMUM MATERIAL SPECIFICATIONS:
1. Any septic tank proposed for installation must be
constructed by a Municipally approved septic tank
manufacturer.
2. The following pipe materials are approved for use in septic
system installations in the Municipality of Anchorage:
Type of Pipe Perforated
Solid
Cast Iron Yes
ASTM D3034 (PVC) Yes
ASTM F810 (HDPE) Yes
ASTM D2662 (ABS) Yes
Yes
Yes
No
Yes
Use of a type of pipe
approved by the
inspecting engineer.
other than listed
above must be
3. Insulation shall be at least 2" thick extruded direct
burial polystyrene (Dow Chemical Company Styrofoam HI or
equal).
4. Septic tank inlets and outlets shall be fitted with
watertight couplings (Caulder, Fernco, or equal).
5. A permeable nontoxic silt barrier (Typar 3401,
140/N, or equal) must be installed between the
leachfield gravel layer and the native soil backfill.
Mirafi
final
6. Ail leachfield gravel (sewer rock) shall be 0.5"-2.5"
screened gravel with less than 3% passing the #200 sieve.
7. When sand is being used as a filter material, its gradation
specifications must conform to current M.O.A. or D.E.C.
requirements.
Page Four
Lot 36; Block 3; Northwoods Subdivision
September 14, 1994
INSPECTIONS:
Typically there will be a minimum of three (3) inspections
required during the installation of the wastewater disposal
system. These inspections will occur as follows:
1. The first inspection must be conducted after the excavation
of ditches, pits, trenches, or beds and before the
installation of any gravel. A septic tank may be set in
place, but may not be backfilled before this inspection.
2. The second inspection must be conducted after the placement
of the silt barrier, gravel, distribution lines,
standpipes, cleanouts, and insulation, but before the
placement of any other backfill.
3. The final inspection is to occur upon final grading of the
property.
Often there will be more than these 3 inspections required,
especially with the installation of multiple trenches, sand
filters, pressurized distribution systems, etc. Thus, the
inspecting engineer is to be contacted at least 24 hours prior to
the start of construction. If necessary, a pre-construction
meeting will take place on-site. The inspecting engineer will not
coordinate, direct or control in any way the contractor's
activities.
The owner shall contract with the contractor to perform the work
outlined in these specifications and plans and in accordance with
the attached M.O.A. permit. There will be no contractual
arrangement existing between the contractor and S & S Engineering.
S & S Engineering shall be the owner's representative and will
inspect the work as stated above to document the contractor's
activities. Final acceptance of the contractor's work rests with
the owner and the M.O.A.
Page Five
Lot 36; Block 3; Northwoods Subdivision
September 14, 1994
S & S Engineering shall have no liability to the owner or to
others for acts or omissions of the contractor or any other
persons performing work on this project or the failure of the
contractor to carry out the work in accordance with these
construction documents. S & S Engineering's inspecting engineer
will not be responsible for the construction means, methods,
techniques, sequence, procedures or the safety precautions
incident to this project.
CONTRACTOR/INSTALLER
~,~. MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION
'I ENVIRONMENTAL ENGINEERING DIVISION
825 L Street - Anchorage, Alaska 99501 Telephone 264-4720
ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
NAME ~'~/.,~ I PUONE ~NEW
MAILING ADD~ES.~ / ~
~ DISTANCE TO: Well. Absorption area Dwelling PERMITNO.
~ Z Manufacturer,s-i Material No. of compartments
~ ~ Liq. capaciw in gallons IF HOMEMADE: Inside length Width Liquid depth
~ ~ DISTANCE TO: Well Dwelling PERMIT NO.
~ Manufacturer /~ //~ Material Liquid capacity in gallons
No. of lines ~ L~ngth of each line ' ~ ~ f~-- ]
Total lengt~ lines Trench width Distance between lines
-- ~ inches
~ ~ Top of tile to finish grade Matorial banoath the Total effecdve absorption
~ inchos
ken,th .~ ~ ~idth ~ [ Deoth j / P[~MIT~O.
~M Typeofcrib Cribdiam~_ Cribd~th Total effective absorption area
~ ~ Well ~ f / ~ .BuiJdifl~unda¢on/ Nearest ot ne
~ Class a~ / ~ Depth ~k:'~ :-~e-: :. '" e;; .~ x~. D~stance to lot hne PERMIT NO.
~ DISTAN~ ~O' Building founda~ ~ewaf}ll~:, ~?~ Septic tank Absorption area{s)
APPCVED /fi__ fi/ / DATE LEGAL
3 (Rev. 3/78)
825 "l" STREET
ANCHORAGE, ALASKA 99501
(907) 264-411~
G[{ORGE M. SULI..IV/\N,
MAYOR
DEPARTiVlEN'F OF }-~ EAI_ T It ,'XNI) ENVII~O?,Jiv1L/,j I'A [ Pf-.'.OTEC FIOB}
October 28, 1981
George Wilmoth
308 G Street, Suite 211
Anchorage,Alaska 99501
Subject: Lot 36 Block 3 North Woods Subdivision
The on-site sewer system serving this unoccupied residence
has flooded with subsurface ground water. This condition will
cause back up and is not an approved dry absorption field.
The absorption system will have to be rebuilt in an elevated
mound manner designed by a professional engineer.
The residence may be occupied in the interium of the septic
ta~k is capped and a pumping routine guaranteed if you so
desire.
If there are any further questions, please call this office
at 264-4720.
Sincerely,
Les N. Buchholz, R.S.
Seni6r Environmental Specialist
LNB/ljw
¢
F'ERMZ"F NO.
FI F' F' L I C: FI l'-~. T
L O C: FI T I 0 N
LEGFIL
LOT SIZE
E8 8-..;2.~" Z-': J..
;2P"~¢:'H::'p;::~ SKU_FIF.'E' FEET
T'-:'F'E Cfi:' SO]:[.. FIBS;OF,'PTION S"r'S;TEM I:5: TRENC:H
HRXIMLIM NUM[:}E:'R Of::' E~EDROC. ff,'IS = ][: SOZL. RFI]'ZNG (:5C.:! FT,?E:R)=
THE REC!LI!FitE[:, 5:[ZE OF THE SOZL I:~,E:SOF.'.F:'TZON S'.?S;TEI'4. I.'S,:
THE LENGTH DtHEN'.:~;I'Oi'.,I :[SE; THE LENC. iTH ET. Iq FEET) OF THE TRENCH OR DRF!tNI::'IEL. D.
THE [:,EF'TH OF' FI TRENCH OR F'.'[T !:S THE [:,I:STFII'.,!CE DE'TI.,.IE:Ef'.,I THE "2:URFFICE: OF THE
GROUNE:, FIN[:, ]"HE E',OT]"OM OF TFIE E::.::CFI',,,'FI]"ION ,::If'.,l FEET).
TFIERE IS:; NO L;ET P.I'[[:,TH FOF.: 'TF'.'ENCHES.
'THE GF.:Ft',,,'EL [:,E:F'TH I':T.., THE MZNIMUH DEF'TH OF GRFI'v'EL BET.b.tEEN THE OUTFF:It....L. PIPE
FIND TFIE BO"I'TOH OF' THE EXCFt',,,'FITION ,::ZN FEET....`.
F'ERMIT I=IF'PLZCFINT HR'S; THE RE:,F .hlz,.Ic, Zl....[ F'~ TO ZNFORM "FFII:5 DEF'RR'T'HENT [:,LIIE:INC~ THE
IN%'FFILL. t~]'Z :f.! ZNSF'ECTIOhE5 OF la[-~'t' I.,-IELLS flE:,JFICENT TO THI:~ F'ROF'ERT'¢ FINE:, THE
NI_ ME:F:R OF RE~S I [:,ENCES 'THFIT THE t.,.IEI....L I.,.I I t_L. ':'FF" 'F'
E~FIC:KF'.T.L.L:[NL~ OF Fil",l"r' %"r"::;]"EM P.II"I"Hcu'r' FII'.,tFIL !N'S.F'E'.':'T'ION FIF,~F, FIF'F'F.'Z','I::.[.. B'¢ TFII';'~
E:,EPFIF.:THE]'-,!T f.41 L.I.... BE '5. E .TE Z '1" TO F'RC 'E E "J. 'T '[ Z t'.,1.
MINIMUH [)I'S"['RNCE BE"I"[,IEEhl R I.,.IELL RND RI',!'¢ ON-SITE SEI.,IFIGE DZSPOSRL SYSTEM
::L~3G FEET FOR R PRI',,,'RTE I.,.IELL OR :~..5¢ TO 208 FEET FROM R PUBLIC: HELL. DEI:::'EI'.,!DZNG
UPON THE 'T'T'PE OF PUBL. IC I.,.IELL.
HINIHUH [:,ISTFII'.,ICE FROM FI F'RIVR'TE !.4ELL. TO R PRIVRTE S;ENER LINE IS ;2:5 FEE]" RND
TO F! COMMUNIT'¢ SEI4ER LINE I5 75 FEET.
OTHER REC!UIREMENTS MR"r' t~F'PLh". 5PECIFICRTIONS RND CONS]'RLIC]-~ON DIFIGRRHS RRE
R",¢RILFIE:L..E TO INSLIRE PROPER iNSTRLL. RTION.
I CERTIF"¢ THFIT
Z: I FIM F:FIHILIFIF: I.,.tITH THE REL.]U!REMENTL::; FOR ON-S;ITE L--.';EP.IERS FIN[:, t.,.tELL:S Fr..'~; SET
FCJRTH D"? TFLE P'tLII'.,!ICIPFiL. IT'T' OF:' FINCHORFIGE.
;2:: I t.,.IIL. L. II",ISTRLL THE S'T'L:.TTEM IN FICC:OF..'E:,BNCE I.,.tITH THE CODES.
3: I LtN[:,ERS;]"FtNr.) ]"FIFIT THE ON-S:ITE SEI.,.IER .S'.¢:STEM I"1FI'¢ RE.:C!UIF.'.E EI'.,ILFIRGEMENT IF' THE
RE'.:::I[:,ENCE I'."S RE:P'IO[:,ELED ]'0 I NCL. UE:,E HORE THRN Z':: BEDROOMS.
:S I GNEE:, ' ...........................................................................
IF I:- L I CFINT'.:-':]'E',,,'E L. :.'+;KFIGGS C ".)N'S;TK...'L ] T I '..] t'-~
/
,r -
I'5'5_ Er., ~; .................................................................................... r_.h ! E.__/_-..&L_L.-.~_t
- 264-4720
~ * * * HANDWRITTEN PERMIT * * *
. WELL AND/OR ~N-SITE SEWER PERMIT
Type of Soil ~sorption System Is:
Trench: Drainfield:'~_ Seepage Bed: Holding
Tank:
Maximum N~ber of ~edrooms: ~- ~ Soil 'Rating(sq.ft/br)
The Required Size o~ Soil ~sorption Systgm Is: ·
The length dimension is the length(in feet) of the trench or drainfield. The
depth of a trench or pit is the distance between the surface of the ground and
the bottom of the excavation(in feet), There is no set width for trenches.
The gravel depth is the minim~ depth of gravel between the outfall pipe and
the bottom of the excavation(in feet).
Permit applicant has the responsibility to inform this department during the
installation inspections of any wells adjacent to this property and the number
of residences that the well will serve,
~ TNO(2) INSPECTTONS ARE REQUIRED ~
Backfillin9 of any system without final inspection and approval by this department
will be subject to prosecution.
Minimum distance between a well and any on-site sewage disposal system is 100 feet
for a private well or 150 to 200 feet from a public well depending upon the type
of public well. Minimum distance from a private well to a private sewer line
is 25 feet and to a community sewer line is 75 feet. Well logs are required
and must be returned to this department within 30 days of the well completion.
Other requirements may apply. Specifications and construction diagrams are
available to insure proper installation.
* * * PERMIT EXPIRES DECEMBER 31j 1 9 8 1 * * *
i certify that:
(1) I am familiar with the requirements for on-site sewers and wells as
set forth by the Municipality of Anchorage.
(2) I will install the system in accordance with codes.
(3) I understand that the on-site sewer system may require enlargement if
the residence is remodeled to include more that 3 bedrooms.
Signe~:
Applicant
SWP/024(1/81)
'O & E,ENL~INEERING & DEVELO~"MENT CO.
Box 90, Davis St., Eagle River, Alaska 99577
694-2774 or 688-2280
Russell Oyster
694-2774
Performed for:
SOIL LOG,
Mailing
Legal Description: ~-~c~,~--
Depth (feet)
Earl Ellis
688-2280
Tel. No.
Soil Characteristics
7__
8__
9__
10__
14__
PLOT PLAN
C0~4.r~£ ~ (1'
PERC. TEST
Ground Water Encountered: Yes
Proposed Installation: Seepage Pit
If yes, what depth
Drain Field ~
Comments:
,,...E %;. T ,, L:,,, F N./ HEFL. TH FINE> E},IVERONHENTFIL F-'ROTECT];ON
",-,,...-':";"= '"L.'" :STREE'F., FI~.Jt]:HZE'R":iF, FI~(.
~'"~ ~"..~ ..... =¥ 'T -8- EE e= ...... ~--. ~.~,, -
F'ERH ~" NO. ( 8~..E~E:82 ::,
RF'F'L. ZCRN'F %KRGGS CON%'TRUCTZON / FL O. E~i~:.: !-, "~
t F~r':RT Z I]KI NARTHI,1!Fff]F:,'::; ';..."D ~ /
LEGFIL. L..Off ..3~: 8L.K 3 NC~RTH!,.tUODS ~D / LOT S.iZE 2808E~ SQURRE FEE]-
f,¢R:,.:;Zr,IUH NUHE, ER OF E:EE:,~OCff,~% = ]:% I SC ZL RFCr"r~. 3 ~"=:E~ F'T.-.'Pk:," = ?4 e
THE F:iEI]:!(..IIF:E[) E;i2~E OF THE SOIL R~,..,,.N=F' STEM
THE [:,EF"T~ ()F R 'TRE~, OR F'Z~ ]E THE E:,'rqTF~.r'F F:E~HE~.~
TFIE GRFI',,,'EL. E:,B H ZS MZ!qZf UM DEPTH OF G~. BETWEEN THE
FiND THE BO]'TE~ OF ]"~ ION (:~:N FEET~
PERM]:' FIPPL!CFINT HFI THE F..'F(':-';t::'-t'-~'ql'FT '["f".? Tn rRH THT': [:, DUF-:ZNG -L~-:'
i"r'z":H INS, F'EE ['.'b.'~: OF FIN'T' WEL_LS R[ ']"HZS RN[.': ?'FIE
.N..HEE:R RE'.'SIDENCEE; THR'I' THE WELL !4~
7E E4: E: E:: ..............
L E'¢ THiS
MIN:[MUH WEEN R WI
!E~E~ FEET FOR WELL ]-O
UPON THE ]".r'F'E LIBLIC WELt..
H!NIMUH I}iSTFINCE FROH FI PRI'v'F!TE !4ELL TO Fl PI:
TC R COHHL.INIT'¢ E;E!-,.IER, ,,L;IiqE~X'~:S 75 FEET.
OTHER RE~;!LIIREi"IEN'!.,V-~;,/ M~.'r F!PP'I,~.¥. SPECtFI.]:FI]":
..... '" .f~ F~'.'.-."; 'T FILLFf T i ON.
H, H]:~..ifl~L.E 'f'O Zi'.,IE;L
. _ ~-E.
F' E F: tr,! :']' T' ,.-... ET_
[.',ISPOSRL. '-5"¢5TE!'! iS
::i PUBLIC HEL. L DE?ENDZNG
SEHER LINE i'S 25 FEET AN[::,
D CONSTRUCTION DIRGRFIM:5 F~RE
I CERT!F'¢ ]'.'HFIT
:L:
I
FFiH:[ L. ! FR
WIml'H
REC!UIREME/T:.'.5 FOR ON-..L, ZITE E;,EHE:RS FIND HE..L'.E; F!S SET
FORTH E:'¢ THE ML.tN.i']IF'FII.'[ .'iF' FINC:HC¢:RGE.
2: Z !4ZI_L !NSTRLL THE 5'T'STEM ZN F',C:C:ORDFINC'E .HZTH THE CODES.
~:: Z UNDERSTRN. D THFIT THE ON-SZ]"E SEWEF.' E;'¢STEM l'4. FI'-r' REQUZF:E ENLIhRGEMENT IF '].'FIE
RESIDENCE: IS REPIODELED 'FO INCLUDE PtOF::E THFtN Z-': E~EDROOMS.
S _f GNE[:,:
RF'PL. ZCRNT SI-(FIGGS CONSTRUC ]." .,.' O!u;
;~. O & E ENG~rNEERING & DEVELOvMENT CO.
Box 90, Davis St., Eagle River, Alaska 99577
694-2774 or 688-2280
Russell Oyster Earl Ellis
694-2774 SOIL LOG 688-2280
Performed for:Name: -~b~T~'~/~'/V~ /-' ~'~'/G~7~ ~/'/~"~-/~' Tel. No
Mailing Address: ~ O, ,~O'~' ~)/ ~-/'/£~'~//'~/~. / /~,~',
Legal Description: z~° 7' ~ / Z~'4'~'~ ~/~, ~.~/ /(~/z~,~7'-/-/Vv~
Depth (feet)
0
~L
Soil Characteristics
10__
11
12 ..
13
14
15__
16__
Ground Water Encountered: Yes ~ No If yes, what depth
Proposed Installation: Seepage Pit Drain Field
Comments:
PLOT PLAN
PERC. TEST
Performed by:
Date: '~/"7/P/
!
(
MUNICIPALITY OF ANCHORAGE (
DEPARTMENT OF HEALTH & HUMAN SERVICEs
Division of Environmental Services -
On-Site ServiCes Section
P.O. Sox 196650 Anchorage[Alaska 99519-6650
343-4744
CERTIFICATE OF HEALTH AUTHORITY
APPROVAL FOR A SINGLE FAMILY DWELLING
Parcel I.D. # O 5"/7 3 1 ¥ ~
1. GENERAL INFORMATION
Complete legal description
Lot 36~ BloCk 3;'North' Woo~ Sub~v~on
Location (site address or directions) _
Property owner
Mailing address
22607 Northwoods Drive
Day phone
22607 Northwoods Drive Chuglak, AK 99567
688-5587Y
552-3563
Lending agency
Mailing address
Agent
Address
AK. USA FEDERAL CREDIT UNION Day phone
P.O. Box 196615~ Anchorage, AK 99519
Day phone
Unless otherwise requested, HAA will be held for pickup.
NUMBER OF BEDROOMS: 3
3. TYPE OF WATER SUPPLY:
Individual well
:" Community well ' XXX
Public Water ",~',"
NOTE: If community well system, provide wfi~en confirmation from State-ADEC
' ing to the legali~ and status of system.
4. TYPE OF WASTEWATER DISPOSAL: -
Individual on-site XXX ', '
Holdingta k = . '- - .... ':': . :"'
': community on-site- " . ...... .- -
'. - Public sewer . ..'-. ~ .. . _
NOTE: If community wastewater system, proWde wri~en confirmation from state
attesting to the legality and Status of syStem:-:
'- .,., . ':.,'- .:~.¥
72~ (Rev. 1/91) Front MOA~I "' ' ' '
STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my
investigation of this Health Authority Approval application shows that the on-site water supply
and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms
and type of structure indicated herein. I further verify that based on the inf'ormation obtained from
the Municipality of Anchorage files and from my investigation and inspection, the on-site water
supply and/or wastewater disposal system is in compliance with all Municipal and State codes,
ordinances, and regulations in effect on the date of this inspection.
Name of Firm S & S ENGINEERINC~ Phone ~q ~- ;LC/7 ~/ .--
17034 Eagle River Loop Road Ne. ~0~
Address .:a¢~le ........ ~
EngineeCs signature ~- '~-?~-~' ~ - ~/~'""~ Date "~/~) ?
DHHS SIGNATURE
Approved for__./~
Disapproved.
Conditional approval for
bedrooms.
bedrooms, with the following stipulations:
The Municipality of Anchorage Department of Health and Human Services (DHHS) issues Health Authority
Approval Certificates based only upon the representations gwen in paragraph 5 above by an independent
professional engineer registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes
and their lending institutions in order to satisfy certain federal and state requirements. Em ployees of DHHS do not
conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage ~s not
· responsible for errors or omissions in the professional engineer's work
72.025 (Rev. 1/91) Back MOA¢~21 '
Municipality of Anchorage
Department of Health and Human Services
HEALTH AUTHORITY APPROVAL CHECKLIST
Legal Description: .,{JO~-/-/~OOZ)5' ~o~D.j'/~oc/:_ $j Z;o?->~4Pamel I.D.
A. Well Data
Well type
Log present (Y~) ~/,,~
Total depth
Sanita~ seal (Y/N)
II(~)B, or C, attach ADEC letter. ADEC water system number
Date completed ,'J/~ Driller
Cased to /F//g Casing height
Wires properly protected (Y/N) '~ ,~,/~
-~--~_~~ROM WELL LOG ~
Date of test ~ ~_~:/~/__
Static water level _ / ~__
Well flow ~ g.P~
Pump teve/j~/-/ '"'"'"""~ ~
SEPARATION .DISTANCES FROM WELL TO:
Septic/heica~ tank on lot
Absorption field on lot 2 Od
Public sewer main 25-~ '-~
Sewer service line
; On adjacent lots
; On adjacent lots
Public sewer manhole/cleanout
Petroleum tank
WATER SAMPLE RESULTS:
Coliform
Date of sample.~ ~
Nitrate ~ ~'-~' Other bacteria
Collected by:
B. SEPTIC/~C TANK DATA
Date installed /~ _/~p. Ez./
Cleanouts (~N) ~/~'~
High water alarm (~1)
Date of pumping /d
SEPARATION DISTANCES FROM SEPTIC/~ TANK TO:
Well(s) on lot
To property line ?d / Absorption field b~ '
Surface water/drainage
Tank size /o~o ~,~z,
Foundation cleanout (~) ~/~-~
Compartments Z.
Depression (Y~) ,,~/d
Alarm tested {~1)
Pumper
Foundation
Water main/service line
72-026 (3/93)° FrOnt CONTINUED ON BACK PAGE
C. LIFT STATION
Date installed
Size in gallons
Vent (Y~ ,Uo
High water alarm level
Meets MOA electrical codes(~N)
"Pump on" level at
z/~,,
Manufacturer
Manhole/Access (~N)
,, "Pump off" Level at ~"
Cycles tested
SEPARATION DISTANCE FROM LIFT STATION TO:
Well on lot 2o¢ /+ On adjacent lots
20,~ ~ Sudace water
D. ABSORPTION FIELD DATA
Date installed /o - / ? - c~ ¥
Length / -~ o ' Width
Total absorption area /; ¢ ? ~'.~' Cleanout present (Y~
Date of adequacy test ~,/~- ,,Jew ~ys'r-~-~ Results (pass/fail)
Water level in absorption field before test
Peroxide treatment (past 12 months) (Y,~
Soil rating (GPD/F¢) ~.
Gravel thickness
~ l/ 6 ~or
After test
If yes, give date
...System type /¢~,~ ~
Total depth ~-'
Depression over field (Y~)J
,,,j/~ _Bedrooms
SEPARATION DISTANCE FROM ABSORPTION FIELD TO:
Well on lot 2o©
To building foundation
On adjacent lots
Surface water
On adjacent lots 2oo '4- Property line
To existing or abandoned system on lot
Cutbank ~'o '> Water main/service line
Driveway, parking/vehicle storage area
Curtain drain
E. ENGINEER'S CERTIFICATION
I certify that I have checked, verified, or conformed to all MOA and HAA guidelines in .~ff¢ct~E~ ~l~,te of this inspection.
Signature
Engineer"s Name
~.~
HAA Fee $ ~.~(~%0
Date of Payment
Receipt Number
72-026 (3/93)' Back
Waiver Fee $
Date of Payment
Receipt Number
MUNICIPALITY OF ANCHORAGE
Department of Health & Human Services
DIVISION OF ENVIRONMENTAL SERVICES
t °e ~ ~" ~ / p'~''' 343-4744
CERTIFICATE OF INSPE~ION FOR HEALTH AUTHORITY APPROVAL OF
ON-SITE SEWER AND WATER FACILITY FOR SINGLE FAMILY DWELLING
Parcel I.D. , ~/ 7 ~ / ~ HAA,
1. GENERAL INFORMATION (Must be completed prior to submittal)
(a) Legal Description (include 10t. block, subdivision, section, township, range)
Location (address or directions)
(b)
Property owner ~,~-
Mailing Address
Telephone: (home)/,,g-~-~'E~ Business
(c) Lending Institution
Mailing Address 1~
(d) Real Estate Company and Agent
Address
Telephone
Telephone
(e)
Mail the HAA to the following address: (or check here ~, if hold for pick up.)
List contact person and day phone number below: ~
1
2. TYPE OF RESIDENCE
Single-Family'l~ Number of bedrooms
3. WATER SUPPLY
Individual Well~,. Community [] Public []
Note: If community well system, must have written confirmation from the State Department of Environmental
Conservation attesting to th legality and status.
4. SEWAGE DISPOSAL
On-sitel~$.. Public [] Community [] Holding Tank []
Note: If community well system, must have written confirmation from the State Department of Environmental
Conservation attesting to the legality and status.
72-025 (Rev. 7/88) Page 1 of 2
5, ENGINEERING FIRM PROVIDING INSPECTIONS, TESTS, FILE SEARCH, DATA AND INFORMATION
As certified by my seal affixed hereto and as of the validation date shown below, Iverifythat'myinvestigation of this
Health Authority Approval shows that the on-site water supply and/or wastewater disposal system is safe,
functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that
based on the information obtained from the Municipality of Anchorage files and from my investigation and
inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and
State codes, ordinances, and regulations in.6ffect on the date of this inspection.
~, -~'~ /v /) ~~/ Telephone . '-* ';~ -
Name of Firm ~' o-O~'--LC~z'¢- ~' '~ 7'~i '/
Address v~'- .~ /" ~'/ /''~- '
6. DHHS APPROVAL
Approved for .-~ bedrooms by
Approved --~ Disapproved
Terms Of Conditional Approval
Conditional
The MunicipalityofAnchorage Department of Health and Human Services(DHHS) issues Health Authority Approval
cerificated based only upon the representations given in paragraph S above by an independent professional engineer
registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes and their lending
institutions in order to satisfy certain federal and state requirements. Employees of DHHSdo not conduct inspections
or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions
in the professional engineer's work.
72-025 (Rev. 7/88) Back Page 2 of 2
.~__.~ MUNICIPALITY OF ANCHORAGE (MOA)
[, e~,~ Health Authority Approval (HAA)
MU~//OF ANCHO~t~IECKLIST - FEBRUARY 1984
~NV[ROk~=~,L £E[,~VICES DWI$ION 343-4744
?!'~ii/ ~ ~! ~88 Legal Description:
A. WELL DATA
Well Classification
Well Log Present (Y/N)
Total Depth__ Cased to
Static Water Level
Casing Height Above Ground
Electrical Wiring in Conduit (Y/N)
SEPARATION DISTANCES FROM WELL:
To Septic/Holding Tank on Lot
To Nearest Edge of Absorption Field on Lot
To Nearest Public Sewer Line
To Nearest Sewer Service Line on Lot
Water Sample Collected by
Water Sample Test Results
Comments
Date Completed
Depth of Grouting
If A, B, C, D.E.C. Approved (Y/N) .
Yield
Pump Set At
Sanitary Seal on Casing (y/N)
Depression Around Wellhead (Y/N)
; On Adjoining Lots
; On Adjoining Lots
To Nearest Public Sewer Cleanout/Manhole
; Date
B. SEPTIC/HOLDING TANK DATA
Date Installed '7/B/ Size
Standpipes (Y/N) y Air-tight Caps (Y/N)
Depression over Tank (Y/N)
Pumping/Maintenance Contact on File (Y/N)
Holding Tank High-Water Alarm (Y/N)
No. of Compartments T ¢J O
y Foundation C!eanout (Y/N) IN/
h///~k, ;for
Temporary Holding Tank Permit (Y/N)
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK:
To Water-Supply Well
To Property Line
To Water Main/Service Line
To Stream, Pond, Lake or Major Drainage Course
To Building Foundation
To Disposal Field
/o h
Comments ·
72-026 (Rev. 7/88) Front Page 1 of 2
C, ABSORPTION FIELD DATA
Soils Rating in Absorption Strata
Date Installed /k/o ~,
Width of Field ~ O
Square Feet of Absortion Area
Depression over Field (Y/N)
Results of Last Adequacy Test
Type of System Design
Length of Field
Depth of Field
Gravel Bed Thickness /
Statndpipes Present (Y/N)
Date of Last Adequacy Test
SEPARATION DISTANCE FROM ABSORPTION FIELD:
To Water-Supply Well
To Building Foundation
Lot
To Water Main/Service Line ~, C.~
To Stream, Pond, Lake, or Major Drainage Course
To Driveway, Parking Area, or Vehicle Storage Area
Comments
To Property Line ~
To Existing or Abandoned System on
; On Adjoining Lots ;> ~'
To Cutback (if present)
IO
D. LIFT STATION
Date Installed J~ v/
Size in Gallons
"Pump On" Level at
High Water Alarm Level at
Tested for
Meets MOA Electrical Codes
Comments
Dimensions
Manhole/Access (Y/N)
"Pump Off" Level at
Vent (Y/N)
Pumping Cycles during Adequacy Test.
**Check Permitted Bedroom Rating Against HAA Request**
I certify that I have checked, verified, or conformed to all MOA and HAA guidelines in effect on the date of this
inspection.
Signed /
I
Company
Engineer's Seal
Date
MOA No.
Receipt No. ~,/~S
Date of Payment /,/_
Amount: $ /"70' U
72-026 (Rev 7/88) Back
Receipt No.
Waiver Fee: $
Date of Payment
Page 2 of 2
DATE RECEIVED
INSPECTION APPOINTMENTS
TIME TIME TIME
: DATE DATE DATE
INSPECTOR INSPECTOR INSPECTOR
MUNICIPALII¥ Or ~,~ ..........
MUNICIPALITY OF ANCHORAGE DEPT. OF HEALTH &
DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTEC'~I~RONMENTAL PROTECTION
825 L Street - Anchorage, Alaska 99501
OOT 1 3 1981
ENVIRONMENTAL SANITATION DIVISION
Telephone 264-4720 R E C El V E D
REQUEST FOR APPROVAL OF INDIVIDUAL WATER AND SEWER FACILITIES
DIRECTIONS: Complete all parts De page 1. Incomplete requests will not be processed, Please allow ten (10) days for processing.
MAILING ADD~ESS
PROPERTY R ESI DENT (If different from above)
MAI LING ADDRESS
3. LENDING INSTITUTION
MAILINGAOORESS ~ O / ~' ~ ~l
"4. REALTOR/AGENT
MAI LING ADDRESS
5. LEGAL DESCRIPTION
STREET LOCATION
fi. TYPE OF RESIDENCE NUMBER OF~BEDROOMS
[~ SINGLE FAMILY [~] One [] Four [] Other
[] Two [] Five
[] MULTIPLE FAMILY ~ Three [] Six
7. WATER SUPPLY
[] INDIVIDUAL*
[] COMMUNITY
PUBLIC UTILITY
8. SEWAGE DISPOSAL SYSTEM
*ATTACH WELL LOG. A well log is required for all wells drilled
since June 1975. For wells drilled prior to that date, give well
depth (attach log if available.)
[] INDIVIDUAL/ON-SITE**
~ PUBLIC UTILITY
/ ~ ~)','/ YEAR ON-SITE SYSTEM WAS INSTALLED.
NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED.
THIS SIDE FOR OFFICIAL USE ONLY
1, TYPE OF RESIDENCE NUMBER OF BEDROOMS
~ SINGLE FAMILY [] ONE E~] THREE E~i FIVE [] OTHER
[] MULTIPLE FAMILY [] TWO [] FOUR [] SIX
~ERMIT NUMBER
2, WATER SUPPLY
~;~ INDIVIDUAL DEPTH OF WELL
[] COMMUNITY DATE DRILLED
[] PUBLIC UTILITY
Connection Verified LOG RECEIVED
~ERMIT NUMBER
3. SEWAGE DISPOSAL SYSTEM
pNDIVIDUAL/ON -SITE DATE INSTALLED
UBLIC UTILITY
Connection Verified INSTALLER
[~eptic Tank or [] Noldin§ Tank
Size://_.~.~ _ If Tank is homemade SOILS RATING
live dimensions:
TYPE OF TANK MANUFACTURER
TOTAL ABSORPTION AREA MATERIAL
4. DISTANCES Septic/H°lding Tank IAbs°rpti°n Area Isewer Line INearest L°t Line
WELL TO:
Absorption Area to nearest Lot Line
5. COMMENTS
~L~;~-~IpTRI oONv~~ APPROVAL (letter must accompany certmcate,
DEPT. OF ENVIRONMENTAL CONSERVATION
ANCHORAGE/WESTERN DISTRICT OFFICE /
3601 C STREET, SUITE 1334
/
ANCHORAGE, ALASKA 99503
STEVE COWPER, GOVERNOR
563-6775
DATE: November 9. 1988
PWSID: 213001
To Whom It May Concern:
According to the records on file in this office, the CHUGIAK
UTILITIES/NORTHWOODS Water System is in compliance with the State
of Alaska Drinking Water Regulations.
VEC:pkk
Sincerely,
Vera E Craig
Environmental Field ~icmr