On-Site Wastewater Disposal System and/or Well Inspection Report
Permit Number: '5'JX/q~°O~ ~ ~ PIDNumber: 0,¢'/-~"/
Name:
7~/.~- ~'//0/~ ~ Ce. Wastewater System: E~,New [] Upgrade
Address: jO. ~. ~0)('
~A ~ ~ ~/~c~ ~ ~ ~ ~- ? ? ABSORPTION FIELD
Phone: Nc. of BeSoms: ~ DeepTrench ~ Shallow Trench ~Bed ~Mound ~ Other
LEGAL DESCRIPTION Soil Rating: Total Depth from original grade:
~. o ~,sq.~. /' D'~ ,~'~)
Subdiv~ion: Depth to pipe bosom from original grads: Gravel depth beneath pipe
Township: ~ Range: ~ Section:~ Fill added above~,original~ grade: Ft. Gravel length: ~ ~ Ft.
WELL: ~ New ~ Upgrade Gravel width: . Number of lines: Distance between lines:
/0 Ft. q ~.~ Ft.
Classification (Private, A,B,C): ~ Total Depth:/ ~ Total absorption area: Pipe material:
Driller: ~ / Date Drilled: Static Water Level: Installer: Date installed:
~ GPM Pump Set at: Ft.II Casing Height Above Ground:Ft. TAN K
SEPARATION DISTANCES ~Septic U Holding ~ S.T.E.P.
To Septic Absorption Lift Holding ~ublic/Private Manufacturer: Capacity in gallons:
..o~ ~.~ .i.,. ~,.t,on ~..~ ~w~r,,n. ~ '~ Z~
Sudace
Water /0~ ~ /O0 '~ ' /00'+ LIFT STATION
Lot ~ ~ ~ ~ Size in,lions: ~ Manufacturer:
"Pump on" level at: "Pump off" level at: High water alarm
.ou.~.t~on ~'' /~ /~ ' ~ ~,, ~,,
Ou~ain Pump Make & Model ~ Electrical Inspections pedormed by:
Drain ~ ~0~ ~ ~ ~0~1 ~. ~~ L,~?~ ~,
Remarks: ~E¢~~E .~ ~/L~ BENCH MARK
Assumed Elevation:
E
17034 Eagle River Loop~ad, No. 204
Inspections pedormed by: ,~~~
~gie Eiver, Aiaska ~;5,, Dates: 1st //- ~- ~ "
2nd /~- ?-~ '~ ~ ~ ,O",,T C. COW~N
'~;~.., CE-880] /~
Department of Healffian~ ~uman ~rvices approval .~.., ......... ~,,,
~~~ ~~ %~,
Reviewed and approved by: Date: Z -/¢- ¢¢
72-013 (Rev. 9/91) MOA 25
PERMIT NO. SW980396 PAGE 2 o~ 3
MuniclpaLit o? Amchoracm
DEPARTMENT OF HEA~THAND HUIVTAN SERVICES
ENVIRONMENTAL SERVICES DIVISION
P.O, Box 196650 eAnchor~lge, Atask~ 99519-6650eTetephone~ 343-4744
ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
LEGAL LOT 20, BLOCK 4, NORTH WOODS
P.i.o. NO, 051-741-03
/ / ---...
.,/ / ~ ~ NEW DRAINFIELD
/ WITH ORENCO /~ /
/ ~.~..~ ~T~./~ ,
/TO SAND FILTER .~o~ ~ ~ / /
~'"~.~T. SITE~/ 715
/ N ~'~ Z / I __APPROX.
/ N ~ -~ ,,7 ~w~.s~.v,c.~L,.~
/
/
19
PERMrr NO. SW980596 PACE ,5 OF 5
Municip. o, Li-t,,/ oF Anchor'aQe
DEPARTMENT OF HEALTH AND HUb'TAN SERVICES
ENVIRONMENTAL SERVICES DIVISION
. P.D. Box 196650 e..Anchor~ge, A[~sR~ 99519-6650 ·Te[ephone, 343-4744
ON-SITE WASTEWATER L)ISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
LOT 20, BLOCK 4, NORTH WOODS
P.LD. NO. 051--741--05
~-FINAL GRADE
98.0' ~INSULATION
93.9' ~ 93.6'
N.T.S.
MT1 =103.3' L ~TTI MT2 MT2=103.8'
MT4=108.6, l X ~--FINAL GRADE~MT~/MT3=103'7'
,~ ~ ~.__~ ' z-ORIGINAL GRADE
7 ~,_ INSULA~
~,~"mu.~ j~~'-__- _-- __ -
r~.u~ ~-~o N.T.S. GROUNDWATER AT 95.6'
ff~'a.o.u.
A B C
~'CO - 12.0' 18.5'
ST1 - 11.5' 25.5'
.~T2 - 12.0' 26.5'
_S - 12.5' 51.0'
VlT1 56.5' 59.0' -
VlT2 58.0' 74.0' -
~T5 65.5' 74.0' -
MT4 44.5' 39.0' -
WED 15:28 HEAVENLY LIGHTS ELECT CO $?~ $894
491 Willow Street · Wasilla, Alask~ 99654
Phone# (907) 373-3893 · Fax# 373-3894
P.02
C! D ~x C~£ I'~,
/"? ~,t v~-tL'~-w':a'' (
MUNICIPALITY OF ANCHORAGE
Department of Health and Human Services
On-Site Services Program
825 L Street, Room 502
P.O. Box 196650, Anchorage, AK 99519-6650
(9O7) 343-4744
ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT
Initial
Date Issued: Oct 05, 1998
Expiration Date: Oct 05, 1999
Permit Number: SW980396
Legal Description: NORTH WOODS BLK 4 LT 20
Design Engineer: 0003 S & S Engineering
Owner Name: Robert Shafer
Owner Address: PO Box 773303
Eagle River, AK 99577-
Parcel ID: 051-741-03
Site Address:
Lot Size: 23098 SQ. FT.
Total Bedrooms: 4 Permit Bedrooms: 4
This permit is for the construction of:
[] Disposal Field [] SepticTank [] Holding Tank [] Privy
[] Private Well [] Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ).
3. The engineer must notify DHHS at least 2 hours prior to each inspection. Provide notification by calling
(907) 343-4744 ( 24 hours ). ( Not required for a Water Supply Permit only ).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
must be either: A. Open and closed on the same day.
B. Covered, sealed, and heated to prevent freezing.
5. The following special provisions.
This permit is for a bottomless intermittant dosing sand filter system.
Received By:
Issued By:
ROBERT C. COWAN, RE.
ROBERT A. SHAFER, RE.
CIVIL ENGINEERS
September 9, 1998
(907) 694-2979
FAX (907) 694-1211
HEALTH AUTHORITY
APPROVALS
SEWER & WATER
MAIN EXTENSIONS
SEWER & WATER
INSPECTION
ENGINEERING STUDIES
AND REPORTS
WELL INSPECTION
& FLOW TEST
SITE PLANS
ROAD DESIGN
SOILTEST
PERCOLATION
TEST
STRUCTURAL&
MECHANICAL
INSPECTIONS
ONSITE
WASTEWATER
DISPOSAL SYSTEM
DESIGN
MUNICIPALITY OF ANCHORAGE
Department of Health and Human Services
P.O. Box 196650
Anchorage, AK. 99519
REFERENCE: Lot 20, Block 4, North Woods Subdivision
Request you issue a permit to install an innovative (Bottomless Sand Filter)septic
system to serve the proposed four bedroom house on the referenced property.
Two test holes were excavated and a percolation test was performed for each hole. The
approximate location of the test holes are indicated on the attached site plan.
At the time of excavation, groundwater was encountered in test hole #3 at 5.5 ft. After
seven day groundwater monitoring, the monitoring tube was checked and groundwater
was at 3.0 ft. During the excavation of test hole #4, groundwater was encottntered at 5.0
ft. After seven day groundwater monitoring, the monitoring tube was checked and
groundwater was at 4.5 ft.
We do not anticipate any adverse effects on neighboring wells, septic systems or
drainage patterns by the installation of the proposed septic system.
There are no points of contamination within the proposed well radius that can be seen
on the attached site plan.
If you require additional information, please contact us.
Sincerely,
Robert C.
RCC/srj
Enclosure
17034 NORTH EAGLE RIVER Loop · SUITE 204 ° EAGLE RIVER, ALASKA 99577
._l's-- 60' SITE PLAN DESIGN
~0 ~m /~ ~
I
/ r~ ~ ~ ' / k / I ~ ~ / ~ o~ ~mo ~ .
~~ - ' ~ '5%'~ ~,
I; I '
N.T.S. PROFILE DETAIL
S, CALE
_~
~ ~ o ~ ~ ' ~
>
z
~ ~ Field cut 4
PVC to Fit ~ ~ ~
~ ~ (sc. 40)
· , , N.T.S. DESIGN DETAIL
SCALE
N.T.S. PROFILE DETAIL
SCALE,,,.%,'~',-.
LEGAL DESORIPTION:~O ~ ~/h( ~F~/~wnship, Range, Section:
Municipality of Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L' Street, Anchorage, Alaska 99502-0650
SOILS LOG -- PERCOLATION TEST
1
2
3
4
5
6
7
8
9-
SLOPE SITE PLAN
10-
11
12
13-
14-
15
16
17
18
19
2O
WAS GROUND WATER
ENCOUNTERED?
IF YES, AT WHAT
DEPTH?
[oring? - ! ~ "" Dale:
Gross Net Depth to Net
Reading Date Time Time Water Drop
z/3/. -
I/ Io; ~ b" IO ?~~' ,
COMMENTS
PERFORMED BY:~034 Ea9le ~iver [~p g~a N~, ~ ~ _ CERTIFY THA~ TH~ TEST WAS PERFORMED IN
Eagl~ ~iv~r, Alaska ~,[~ ........ EFFECT
ACCORDANCE WITH ALL STATE AND MUNICiPaL ~u ~.INES IN ON THIS DATE. DATE: ~ ~ ~ ~
72-008 (Rev. 4/85)
Municipality of Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L" Street, Anchorage, Alaska 99502-0650
SOILS LOG -- PERCOLATION TEST
PERFORMED FOR:
LEGAL DESCR,PTION:
8/~' ~ ,/~,~'~hip, Range, Section:
1
2
3
4
5
6
7
8
9
10
11
12
13
14-
15-
16-
17
18
19-
20-
WAS GROUND WATER
ENCOUNTERED?
IF YES, AT WHAT
DEPTH?
SLOPE
SITE PLAN
/ / ~_
E
P~a Gross Net Depth to Net
ding Date Time Time Water Drop
~ ~.'~ ~# i~,' ~,,
PERCOE'ATION RATE (-~inutes/inch) PERC HOLE DIAMETER
COMMENTS / ~/
S&SENGINEERING , ~ ! ').,
~agle ~lYer~ AlaSKa ~V3// '
ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE:
72-008 (Rev. 4/85)
ROBERT C. COWAN, RE.
ROBERT A. SHAFER, RE.
CIVIL ENGINEERS
HEALTH AUTHORITY
APPROVALS
SEWER & WATER
MAIN EXTENSIONS
SEWER & WATER
INSPECTION
ENGINEERING STUDIES
AND REPORTS
WELL INSPECTION
& FLOW TEST
SITE PLANS
ROAD DESIGN
SOIL TEST
PERCOLATION
TEST
STRUCTURAL &
MECHANICAL
INSPECTIONS
ONSITE
WASTEWATER
DISPOSAL SYSTEM
OESIGN
August 4, 1998
(907) 694-2979
FAX (907) 694-1211
BOTTOMLESS INTERMITTENT SAND FILTER SPECIFICATIONS
Lot 20, Block 4, North Woods Subdivision
GENERAL STATEMENT OF WORK
The work covered by these specifications and the plans consist of furnishing all labor,
materials, tools, transportation, and equipment necessary to complete an intermittent sand filter
system as described herein and on the attached drawings.
All work under this project shall comply with the latest edition and addendum to all applicable
codes, ordinances and standards including Municipality of Anchorage-Dept. of Health and
Human Services (MOA)-(DHHS) septic installation guidelines and On-Site Waste Water
Disposal Systems permits.
4 Bedroom Single-Family Dwelling = 600 GPD
Use 2.0 GPD/SF for polished effluent
300 sq. ft. required
360 sq. ft. sand filter and absorption area
Sand filter to be constructed on accepting soil
SITE INVESTIGATION
The Contractor who proposes to complete this project must carefully examine the project
documents, have full knowledge thereof, have investigated the site, and be satisfied with the
conditions affecting the work. Conditions include, but are not limited to those bearing upon
transportation, disposal, handling and storage of materials, availability of labor, water, electric
power, roads, and uncertainties of weather, physical conditions at the site including all
underground utilities, the conformation and condition of the ground, the character of equipment
and facilities needed preliminary to and during prosecution of the work. The Contractor must
be satisfied with the character, quality and quantity of surface and subsurface materials or
obstacles to be encountered insofar as this information is reasonably ascertainable from an
inspection of the site, including all prior exploratory work, as well as from information
presented by the plans and specifications made a part of this project. Any failure by the
Contractor to become acquainted with the available information will not relieve him/her from
responsibility for performing the work as stated in these specifications and drawings.
17034 NORTH EAGLE RIVER LOOP ° SUITE 204 ° EAGLE RIVER, ALASKA 99577
Page 2
Lot 20, Block 4
North Woods Subdivision
August 4, 1998
Location of utilities will be the contractor's responsibility. At least forty-eight (48) hours prior to
commencing work, the Contractor shall contract all local utility companies to obtain underground utility
locates. The Contractor shall exert due care to prevent damage to utilities. Should a utility be damaged,
the Contractor shall notify the utility company and shall have repaired at his own expense any damage
resulting from failure of the Contractor to request an underground utility locate or to exert due care. If any
utility company determines that a utility has to be temporarily raised, lowered, moved, guyed, shored,
braced or otherwise protected during construction, it shall be done at the expense of the Contractor to the
satisfaction of the utility company.
INSPECTIONS
Typically, there will be a minimum of four (4) inspections required during the installation of the waste
water disposal system. These inspections will occur as follow:
Inspection of work in progress may be made by the Engineer and MOA-DHHS at any time. The following
schedule of required inspections is to be adhered to. Twenty-four (24) hours notice is required prior to each
inspection. Inspections can only be arranged during weekdays and during normal working hours. The
following inspection schedule is to be strictly adhered to:
Septic tank/lift station is in place, but not backfilled. Sewer piping from building to tank is
complete and properly bedded. Sand filter location is excavated and prepared for filter
construction.
Engineer to be notified with Contractor's schedule during actual construction of the sand
filter to allow spot inspection during construction. Any deviation from reported schedule is
to be reported to the Engineer.
Final inspection of the sand filter with all pressure piping in place, but prior to placement of
cover material. Test pressure piping to ensure adequate flow and pressure, (requires
completion of lift station wiring and piping prior to this inspection).
4. Inspection of final grading and adequate cover.
The Owner shall contract with the Contractor to perform the work outlined in these specifications, plans
and in accordance with the attached MOA permit. There will be no contractual arrangement existing
between the Contractor and S&S Engineering. S&S Engineering shall be the Owners' representative and
will inspect the work as stated above to document the Contractor's activities. Final acceptance of the
Contractor's work rests with the Owner and the MOA.
S&S Engineering shall have no liability to the Owner or to others for acts or omissions of the Contractor or
any other persons performing work on this project or the failure of the Contractor to carry out the work in
accordance with these construction documents. S&S Engineering's inspecting Engineer will not be
Page 3
Lot 20, Block 4
North Woods Subdivision
August 4, 1998
responsible for the construction means, methods, techniques, sequence, procedures or the safety
precautions incident to this project.
All landscaping, fences, sidewalks, paving, driveways, utility markers and other improvements, removed to
facilitate the Contractor's operations shall be fully restored to their original condition and location by the
Contractor unless otherwise directed by the Engineer.
Items damaged by the Contractor during removal, storage, or restoration, shall be repaired or replaced in
kind by the Contractor. This work shall be considered incidental to the project.
MINIMUM MATERIAL SPECIFICATIONS
1. Any septic tank proposed for installation must be constructed by a Municipally approved septic
tank manufacturer.
2. The following pipe materials are approved for use in septic system installations in the
Municipality of Anchorage:
T_vpe of Pipe Perforated Solid
Cast Iron Yes Yes
ASTM D3034 (PVC) Yes Yes
ASTM F810 (HDPE) Yes No
ASTM D2662 (ABS) Yes Yes
ASTM D2241 Yes Yes
ASTM D2239-74 Yes Yes
Use of a type of pipe other than listed above must be approved by the inspecting Engineer.
3. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical
Company Styrofoam HI or equal).
4. Septic tank inlets and outlets shall be fitted with water tight couplings (Caulder, Femco, or
equal).
SEPTIC TANK/LIFT STATION
General
The work under this section consists of the performance of all operations pertaining to
furnishing and installing the septic tank/lift station and piping to the sand filter.
Page 4
Lot 20, Block 4
North Woods Subdivision
August 4, 1998
B. Materials
1. Tank for Lift Systems
a. Septic tank shall be a 1300 gallon two compartment tank for use with
Orenco Systems, Inc. patented lift station assembly or approved equal.
The tanks shall be designed for adequate burial depth as required by
MOA and State regulations. The design or analysis shall be in
accordance with accepted engineering practice and local regulatory
agencies.
c. In areas with high ground water, the tank shall be adequately weighted
or anchored to prevent flotation if the tank is pumped.
2. Risers
a. First compartment shall have a separate 4" pump out riser. The
second compartment shall have a separate 4" pump out riser.
An additional second compartment manhole riser shall extend above
surface grade, shall have a minimum nominal diameter of 24", and
shall be capable of being equipped with the following:
1. A junction (Nema 4x) box or equal, bonded or attached to
the riser.
2. UL listed electrical cord grips, installed in the J-box.
c. A lid - shall be furnished with the riser. It shall be constructed to meet
H-10 loading requirements and have a latching mechanism.
d. Riser installation - each riser shall be sealed or welded to the top of the
tank in such a manner as to prevent infiltration of ground water.
e. Lid insulation - 4" rigid extruded polystyrene shall be placed inside
and attached to the lid.
f. Riser insulation - 2" sprayed shop applied urethane on circumference
of riser with 46465 Tnemec coating.
Page 5
Lot 20, Block 4
North Woods Subdivision
August 4, 1998
3. Effluent Pumping Assembly
a. Effluent pumping assembly shall be Orenco systems (TM) Model 20-
OSI-05-HHF series, or approved equal consisting of the following:
1. 1/2 H.P. 110/120 volt or equal U.L. Listed effluent pump.
Screened pump vault (U.S. patent No. 4439323) 59" deep,
3/16" thick high-density PVC cylinder houses the pump,
level controls and screen and serves as a baffle to prevent the
screen from clogging.
o
Fifteen 1 1/2" diameter holes are drilled in the vault at a level
that places them at about the midway point of the depth in
the septic tank.
Flap check: Allows the vault to drain when removing the
tank. Screen: 15" diameter cylinder of high-density
polyethylene 1/8" mesh.
5. All piping shall be PVC or other non-corroding material.
b. Pump controls and alarm system shall be Orenco systems
SICTETMRO 110 volt with the following options consisting of:
1. Event counter
2. Elapsed time meter
3. Program timer
4. 10 watt heater
Remote alarm panel option with a minimum of 80 DB sound
pressure at 24", operating temperature 30°C to 65°C,
continuous sound to be located inside the home.
6. Oil-tight visual alarm with push-to-silence feature.
Automatic audio-alarm reset.
15 amp motor rated toggle switch, double pole, double throw
with three positions; manual (man), automatic (auto) and
center (off) (H.O.A.).
Page 6
Lot 20, Block 4
North Woods Subdivision
August 4, 1998
8. Nema 4x-rated, fiberglass, or equal, enclosure with hinged
cover.
9. All controls to be installed as per manufacturer's
recommendations.
10. Control panel to be installed on outside wall of home within
sight of septic tank/lift station.
Piping from the septic tank to the sand filter is to be 1 1/4" PVC
schedule 40 solvent weld piping properly bedded and sloped to drain
back to the septic tank. Insulation board 2" thick and 2' wide centered
over pipe is to be placed where soil cover is less than 4' depth over
pipe.
CONSTRUCTION SEQUENCE
In order to ensure proper installation, the system is to be installed in the following order:
1. Sewer line from house to tank
2. Septic tank/lift station
3. Sand filter
4. Final grading
CONSTRUCTION
1. Pipe Grade and Alignment
Variance of individual pipe sections from established line and grade shall not be greater
than 0.05 feet, providing that such variance does not result in a level or reverse sloping
invert.
During the progress of the work, the Contractor shall provide instruments such as transits,
or levels, for transferring grades from offset hubs or other construction guides from the
control points and bench marks provided to the Contractor by the Engineer. The Contractor
shall provide qualified personnel to use such instruments and who shall have the duty and
responsibility for placing and maintaining such construction guides.
2. Pipe Laying
All pipe shall be laid with Class C bedding, free of large stones and organic matter.
Page 7
Lot' 20, Block 4
North Woods Subdivision
August 4, 1998
Each section of pipe shall be handled carefully and placed accurately, the spigot end shall
be fully inserted pointing in the direction of flow and glued in place to make a water tight
seal.
Each section of pipe shall be properly supported to ensure tree alignment and an invert
which is smooth and free from roughness or irregularity.
At all times, when work is not in progress, open ends of pipe and fittings shall be securely
and satisfactorily closed so that no undesirable substance will enter the end of the pipe or
fittings.
Bedding of Pipe for Sewer Lines
The pipe should be bedded with Class C bedding materials, compacted to 95%. Native
materials may be used as back fill material above the pipe, provided it is free of large stones
and organic matter to a point one (1) foot above the top of the pipe.
All pumping services shall be installed in accordance with the manufacturer's
recommendations and standards. Electrical installation is to be to code by a licensed
electrical contractor, with Municipality inspection where required. If MOA inspection is
not required, a licensed electrician is to provide a letter to the Engineer stating that the
system meets or exceeds all applicable codes.
Tank Installation
Excavate to proper depth to allow gravity flow, install tank level, tolerance 0.1 foot, end to
end, on undisturbed or compacted to 95% classified sand fill material. Line excavated tank
pit walls with 2" +35 PSI burial foam full depth of tank. Back fill between tank and foam
and compact in a manner to prevent damage to tank surface coating.
Create a level sand surface over the tank and add 2" burial foam +35 PSI directly over tank.
Mound unclassified soil over tank location to a depth of 2' above finished grade to allow
positive drainage away from tank and counteract buoyancy.
Connections
All connections to be as per MOA-DHHS and UPS requirements PVC 3034 piping with
Caulder or equivalent couplings for inlet riser pipes.
All tank connections are to be completely water tight.
Page 8
Lof 20, Block 4
North Woods Subdivision
August 4, 1998
SAND FILTER
The work under this section consists of materials and construction/installation of the sand filter.
A. Materials
The Contractor shall provide a washed sand to meet ASTM CM33 Concrete
Sand Specifications with the additional requirement that all but 1% of the
materials passing the #100 sieve be removed. A sample may be taken from the
sand bed during construction for purposes of quality control. If the sample does
not meet specifications, all sand will be removed and replaced.
The Contractor shall provide pea gravel that shall be a washed material
containing no fines (0% passing the #100 sieve) and a maximum size of 1/4"
diameter.
3. The Contractor shall provide round rock that shall be washed gravel with
rounded edges, well graded with maximum diameter of 1/2".
°
The Contractor shall provide the manifold assembly. The manifold assembly
shall be the Orenco Model SFM 1036 or equivalent with orifice shields and
flushing assembly. All drilled holes to be cleaned of burrs and pipes flushed,
prior to assembly. Flushing valve to include riser to +12" above finish grade
with extension handle provided to operate globe valve from the ground surface.
5. Side walls and top of the filter box to be insulated with 2" direct burial
polystyrene insulation and be inside the plywood box.
6. The Contractor shall provide the filter fabric.
o
The linear air diffuser line and compressor are available from Orenco, no model
number available. The feed line from the house to the filter is HDPE arctic
insulated pipe 3/4"-2" SDR-11 Maskell-Robbins or equivalent. The
compressor will have a gauge (0-10 psi) and be installed in a heated area, crawl
space, or garage.
B. Construction of Sand Filter
The sand filter construction is to follow procedures as outlined in the Orenco Installation
Manual as applicable to this design.
Rock, pea gravel and filter sand are to be hand leveled to proper depth (tolerance within
0.05 feet) in filter, taking care not to allow mud or fine soil material into the filter or rock
layers. This would include any soil material picked up by excavation machinery buckets
Page 9
Loi 20, Block 4
North Woods Subdivision
August 4, 1998
while loading specified material. The Contractor should estimate filter material volumes
such that allowance is made for wastage of material in contact with the ground at site.
Work on the sand filter may be suspended at the Engineer's discretion due to inclement
weather conditions, such as rainfall. The sand filter and material stockpiles will be
completely covered by a tarp over night during construction until finished. Filter internal
construction should be accomplished in one (1) day's time.
The area over the sand filter to be finish graded with a minimum of 2 feet of cover and to
prevent ponding of surface water run off. Side slopes shall not exceed 3:1. Six inches of
top soil and seed are required over the entire sand filter when the side slopes approach 3:1,
or at the discretion of the M.O.A.
The Engineer will reject any sand, round rock or pea gravel that does not meet
specifications or is contaminated in transit or while handling. If such material is placed in
the filter, all soil material may be required to be removed and replaced with new material.
CONTRACTOR/INSTALLER
MUNICIPALITY OF ANCHORAGE
Development Services Department Phone: 907-343-7904
On -Site Water & Wastewater Section Fax: 907-343-7997
Certificate of On -Site Systems Approval
Parcel I.D. 051-741-03-000
Expiration Date:
Legal description NORTH WOODS BLK 4 LT 20
Site address 22747 MC MANUS DR Chugiak AK 99567
Current property owner(s) SLATER JASON M & ADRIENNE D
10/15/2025
X The On-site system(s) is/are approved for 3 bedrooms
Conditional approval for bedrooms, with the following stipulations:
Comments or advisories:
By:
Original Certificate Date: 10/18/2024
his Certificate of On -Site Systems Approval (COSA) is intended to demonstrate the subject
system(s) is/are in substantial compliance with municipal code. The Municipality of
Anchorage, Development Services Department (DSD) issues COSAs based upon
representations provided by an independent professional engineer. The Municipality of
Anchorage is not responsible for errors or omissions in the professional engineer's work.
ATTACHMENTS:
COSA Checklist X Well Flow Advisory
Absorption Field Advisory Nitrate Advisory
Tank Age Advisory Arsenic Advisory
Other
COSA Approvd_June 2022
MUNICIPALITY OF
Development Services Department
On -Site Water & Wastewater Section
ANCHORAGE
Phone: 907-343-7904
Fax: 907-343-7997
Certificate of On -Site Systems Approval Application
1. GENERAL INFORMATION
Parcel I.D. 051-741-03
Complete legal description NORTH WOODS BLOCK 4 LOT 20
Location (site address) 22747 MCMANUS DRIVE, CHUGIAK, AK 99567
Current property owner(s) JASON & ADRIENNE SLATER Day phone
2. ON-SITE SYSTEMS SIZED FOR 4 BEDROOMS
3. TYPE OF WATER SUPPLY: ❑ Private Well ❑ Private Well serving 2 dwelling units
❑ Private Well serving 3+ dwelling units ® Community Well or Public
❑ Water Storage
4. TYPE OF WASTEWATER DISPOSAL: ® Private Septic ❑ Private Septic serving 2 dwelling units
❑ Holding Tank ❑ Community Septic or Public Sewer
5. SEPTIC TANK: ❑ Steel ® Plastic ❑ Concrete ❑ Fiberglass
Age 25 - See advisory if steel older than 20 years
6. ABSORPTION FIELD: ® AWWTS ® Bed ❑ Deep Trench ❑ Wide Trench ❑ Seepage Pit
Waiver request for: Distance:
Expedited review requested: ❑
By applying for this entitlement, this property is subject to inspection by municipal On-site staff
to verify the accuracy of the information provided.
COSA Fee $ Waiver Fee $
Date of Payment > 2 ° =7' Date of Payment
COSA # 0S C - Z y/ Co Waiver #
COSA Applicalion.doc
COSA Checklist.docx
COSA Checklist
Legal Description: NORTH WOODS BLOCK 4 LOT 20 Parcel ID: 051-740-03
If more than 1 well and/or septic system on lot, provide separate checklist. Structure served by this system ____
A. WELL DATA - COMMUNITY WELL
Well log is filed with Onsite (or attached)
Date drilled Total depth ft
Cased to ft
Sanitary seal is functioning correctly
Wires are properly protected
Casing height (above ground) in.
Date of flow test for COSA
Static water level at beginning of test ft.
Well production at time of test gpm
Water storage tank volume gallons
Well disinfected for coliform test? Yes No
Coliform bacteria is Negative
Nitrate mg/L Nitrate less than MRL (ND)
Arsenic ug/L Arsenic less than MRL (ND)
Collected by Date _____
Comments
B. TANK DATA
Measured operating fluid level in septic tank NA*
Date of pumping 6/19/24
Required maintenance completed, if AWWTS
Comments: *FLOATS
C. LIFT STATION
Required maintenance completed
Age of lift station 25 years
Lift station material PLASTIC
Comments: IDSF & LS WAS MAINT BY L&S SERVICES
D. ABSORPTION FIELD DATA
Which system tested (date installed) 1/19/1999
ALL standpipes present per record drawing
Total measured depth from grade 3.8 ft (max)
Measured depth to pipe invert from grade ft (min)
N/A – pressurized field.
Per record drawings, field is insulated.
Monitor tubes (MT) go to bottom of effective (ED).
If not, state depth into effective
Presoaked required if
(Required if house vacant or field not used for more
than 30 days prior to date of test)
Gallons introduced gallons date
Any rejuvenation treatment (past 12 months) N
If yes, enter date
Adequacy test date 6/19/24
Results Pass
Fluid depth prior to test 0 in
Water added 600 gal
New fluid depth 1 in
Elapsed time <20 min
Final fluid depth 0 in
Absorption rate 600 gpd
FIELD STATUS – POST RECOVERY
Effective depth (per record drawings) 6 in (MOA 0.5’ ED)
Effective depth used 0 in (Final Fluid Depth)
Effective depth (ED) remaining 6 in
Comments/Deficiencies: Approximate total measured depths from existing grade. ED per visual observations,
measurements and MOA record documents.
COSA Checklist.docx
E. SEPARATION DISTANCES
From Private Well on Lot to: (Please enter distances if less than required or if community well on lot)
Septic Tank/Lift Station on Lot > 100’
Yes if No *50+ ft
Neighboring Tank > 100’ Yes if No ft
Absorption Field on Lot > 100’ Yes if No *50+ ft
Neighboring Absorption Fields > 100’
Yes if No ft
Community Sewer Main > 75’ Yes if No ft
Community Sewer Manhole/Cleanout > 100’
Yes if No ft
Private Sewer/Septic Line > 25’ Yes if No ft
Holding Tank > 100’ Yes if No ft
Animal Containment > 50’ Yes if No ft
Manure/Animal Excreta Storage > 100’
Yes if No ft
N/A – Served by Community Well (not on lot) or Public Water
From Septic/Holding Tank and Absorption Field(s) on Lot to: (Please enter distances if less than required)
Building Foundations > 10’ Yes if No **5 ft
Tank to Property Line > 5’ Yes if No ft
Field to Property Line > 10’ Yes if No *5+ ft
Water Main > 10’ Yes if No ft
Water Service Line > 10’ Yes if No ft
Surface Water > 100’ Yes if No *50+ ft
Wells on Adjacent Lots:
Private Wells > 100’ Yes if No *50+ ft
Community Wells > 200’ Yes if No ft
If tank or field is under driveway comment below
F. ENGINEER’S COMMENTS
*MAY MEET CONVENTIONAL SEPARATIONS, BUT SYSTEM MEETS CATII/III SEPARATION DISTANCE REQUIREMENTS.
**PER CODE AT INSTALLATION.
G. CERTIFICATION & STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based
on procedures outlined in the Certificate of On-Site Systems Approval Guidelines, indicates that the on-site water
supply and/or wastewater disposal system appears to comply with applicable Municipal and State codes,
ordinances, and regulations in effect at the time of installation, unless noted otherwise.
Name of Firm FIRST WATER CONSULTING Phone 907-350-9566
Engineer’s Printed Name CURTIS HUFFMAN, PE Date 8/12/2024
Comments: This investigation was completed in compliance with MOA guidelines, regulations,
and best industry practices / methods. The assessment of the condition of the well and septic
applies only to the conditions as of the day tested. The flow and absorption rates may change
due to subsurface conditions that may not be observed from the surface, changes in land use,
local soil characteristics, groundwater levels that may fluctuate during the year, quality of
construction (workmanship & materials), the water usage of the family being served by the
system and maintenance. The operational life of all well and septic systems are subject to
these various and dynamic characteristics and are outside the control of the evaluator of the
well and septic system. Therefore, any or NO estimate of how long a system will function satisfactory
for current or future occupants or guarantee that no unseen encroachments, deficiencies or
discrepancies exist can be given by First Water Consulting &
8/12/24
iVIMC[PAUN OF A11CRoRAon • Comrauni;zy Aevelopmeot Depar=cnt • On,Sitc Wator & Wastewater PrQgMnl
P: 907-3439904 ^ F: 907-343-7997 • P.O. RoX 196650 ADQJ,orage, AK 99519-6650 a http://wvi�rv.muni.4rg/bvild�a�
Intermittent Dosing Sand Filter
Maintenance Log
Owner _ Street Address X1722 Mc, I—Vk(n �% S
Phone Legal Dese. PID _._
§eatic `tare
-Sludge level „inches -Pumping: required s o -Pumping completed$
/bsorotron dead:
.,
-Liquid level inches -Flushing valves per approved design4-P-0
-All flushing valves opened, distribution lines flushed, and flushing valves closed no
i.,ift station:
,,Pump basket cleaned es o •Biotube effluent filter cleaned es no /
-Timer float setting inches -High level float setting inches -Reference point. D a
-Pump on__( _0 seconds Pump off ®M minutes
-cumulative lifetime cycles �0 b ��, -Cumulative run time 6 9 ,curs
6
-Operation satisfactory 9 —0
Air System: 1
-Air pump filter cleaned es o -Air pressure •-,�.--psi 1�
-Date of latest install or rebuiid -,-Air system operation safiisfacto o satin ticto Y
Alert SKatrn
-Dedicated electrical circuit es no •Audible and visual alarm inside dwelling no
.f;�cto
-Float setting inches ,Alarm system operation attafacten not satiM„._M�
Comments:
........................................ ........... ....... .......................... ............ I ......... .,........ .......................................
............................................................................................. ....
..........................................................................................I.....................
................................................................................................................................................
ti
Maintenance Provider:
Technioian cc W 3 J Date of maintenance__ �I
Company
Signature
ID- Maintenance Log_040313,00
Deas..._
AN IDSF - INTERMITTENT DOSING SAND FILTER
NORTH WOODS B4, L20
OWNER:
By'` C_ y� l/Gy ' u` (signature) Date:
(`yank C' ij(print name)
STATE OF A -L— �,
Gfi'. iG' C
10167 (YA ) 55.
lv/15/-)I
The foregoing instrument was acknowledged before me tills /� day of 1%i?/; &C",
204, by S hglzor, Lee (114w16,
CcmTc^wea::^ Fr.— • � s.._.�
�'�6TARY PUBLIC FOR A -L— �� P� ShARON s! °alar - Nota: f sea.
ARK - No[ary Pubic
My Commission expires: 1/- �D-1(p-ycoming County
My:o•r^fission ExpiresAprif 20, 2026
Ccm,^issien Nu,7ber 1255437
/1
;signature)Date: IT/
�U /
print name) Title:
(rev. 05/18/2018) Page 3 of 3
Municipality of Anchorage
Development Services Department
Building Safety Division
On-Site Water and Wastewater Program
4700 Bragaw Street
P.O. Box 196650
Anchorage, AK 99519-6650
www. muni.org/onsite
(907) 343-7904
CERTIFICATE OF ON-SITE SYSTEMS APPROVAL
FOR A SINGLE FAMILY DWELLING
Parcel I.D. osx-7zF~-o3
GENERAL INFORMATION
Complete legal description North Woods, Block 4, Lot 2o
Location (site address) 22767McManus Drive
COSA # O%C/.L ~/Iq
Expiration Date:
Current Property owner(s) Brenton Alesander & Teresa O'Connor
Mailing address
Day phone
Lending agency
Mailing address
Day phone
=
Real Estate Agent Tim Kelly/Dan Wolf Team
Mailing Addres,~, ~ "L~,
Unless O~hetwise requostod,',¢~A will bo
NUMBER OF BEDRQOMS~ ~:;: ..
Day phone 632-62o5
TYPE OF w/~E~ s. UCpL~:
Individdal Well ..... .-'
Individual Water St0~'ge
Community Class ~Well
Public Water System
TYPE OF WASTEWATER DISPOSAL:
Individual On-site
Individual Holding Tank
Community On-site
Public Sewer
D
D
The Municipality of Anchorage Development Services Department (DSD) issues Certificates of On-Site Systems
Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil
engineer registered in the State of Alaska. Certificates of On-Site Systems Approval are required for the transfer of
title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water
supply system. DSD also issues COSAs upon request to homeowners. Certificates of On-Site Systems Approval
are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued
with new water sample results. (Certificates may be reissued for a period of up to one year with valid water
samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system.
The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work.
4. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation,
based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application,
shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the information
obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water
supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes,
ordinances, and regulations in effect at the time of installation.
Name of Firm Pannone Engineering Services, LLC Phone 272-8218
Address P.O. Box ~.oo217, Anchorage, AK 995zo
Engineer's Printed Name Steven R. Pannone, P.E. Date 11/28/201~.
Engineers Comments: In conducting an adequacy test,' I attempt to provide a thorough, conscientious engineering analysis of the system in
accordance with MOA DSD Guidelines & Regulations. The reported results describe the performance of the system under the conditions
encountered at the time of the test, and separation distances measured to readily identifiable features.
The operational life of all wells and septic systems depend on the local soil condition, ground water
levels that may fluctuate during the year, and the water usage of the family being served by the system.
These conditions are outside the control of the evaluator of this system. All systems eventually fail and
satisfactory test results do not guarantee future performance of the system, nor do they guarantee that
there are no hidden defects or encroachments. PES can therefore not provide any warranty for future
performance nor give any estimate of how long the system will continue to meet the operational
requirements of the MOA DSD. The content of this report is for the sole benefit of the owner listed
above. Any reliance upon or use of this report by any other person or party is not authorized nor will it
confer any legal right whatsoever.
5. DSD SIGNATURE
t,"" Approved for '~ bedrooms.
Disapproved.
Conditional approval for
bedrooms, with the following stipulations:
· ,,:,
.'"";:*0:z
ON-SITE
; WASTEWATER
L~))) i 11:~~'
Attachments:
COSA Checklist
Septic System Advisory
Well Flow Advisory
Nitrate Advisory
X
Arsenic Advisory
Maintenance Agreements
Supplemental Engineer's Report
Other
(Rev. 11/05) /
Original Certificate Date:
Municipality of Anchorage
Development Services Department
Building Safety Division
On-Site Water & Wastewater Program
4700 Bragaw Street
P.O. Box 196650
Anchorage, AK 99519-6650
www. muni.org/onsite
(907) 343-7904
CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST
Legal DesCription: North Woods, Block 4, Lot 2o ~
A. WELL DATA
Parcel ID: o~.-7,..~.o3
Well type Public
Date completed ,.
Total depth
Date of test
Static water level
Well production J
WATER SAM PL~~TS:
A~enic'~~'- ug/I '- '
SEPTIC/HOLDING TANK DATA
If A, B, or C provide PWSID # Well Log~~
Sanitary seal (Y/N) W~ly~protected (Y/N)
Cased to ft.~ ~'~sing height (above ground)
FROM WELL LOG ' J~AT INSPECTION
~ ft. ft.
in.
g.p.m, g.p.m.
Nitrate mg/L
Date of sa~nple:
COllected by:
Tank TYpe/Material .... Premier, Polyethylene
Tank size- z=loo ga!.. Number of Compartments
Date installed a21,-lagq8
Cleanouts (Y/N) Y
Foundation cleanout (Y/N) Y
Date of pumping'
Depression over tank (Y/N) N High water alarm (Y/N) Y
Pumper ~,~t-'~f~'~~,-~ ~~
C. ABSORPTION FIELD DATA
Date installed ~.~,1~h.~98 Soil rating (g.p.d./~ or ~/bdrm) 2.0 g_~d/sf
Length .36 ft. Width =o ft.
Total depth 2.; - _~.F ft.. Eft. absorption area 960 ~ Monitoring tube Y
System type Bed I Mound
Gravel below pipe 0.5
Depression over field N
Date of adequacy test aal:tni',o~.., ResultS (Pass/Fail) PASS
For .~ bedrooms
Fluid depth in absorption field before test _o in.
Elapsed Time: ~.8o min. Final fluid depth _o in.
Any rejuvenation treatment (past 12 mo.) (Y/N & type)
Water added6~.2 gal. New depth3 in.
Absorption rate >= 600+ g.p.d.
If yes, give date
D. LIFT STATION
Date installed
"Pumpon" level at
Datum Bottom of Tank
E. SEPARATION DISTANCES
Size in gallons
"Pump oH' level at 3~ in.
Cycles tested 3
Manhole/Access (Y/N) Y
High water alarm level at z~4
Meets alarm & circuit requirements? Y
in.
SEPARATION DISTANCES FROM WELL ON LOT TO:
on lot
Absorption field o~
Public sewer main
Sewer/septic service line
Animal containment areas
On adjacent lots
On adjacent lots
Public sewer manhole/cleanout
Manure/animal excrete~
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO:
Building foundation
Property line ~.o+
Absorption field.
Water main ~.o+
Water service line
Surface water ~.oo+
Wells on adjacent lots ~.oo+
SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO:
F=
Gw
Property line ~o+
Water Service line ~.o+
Curtain drain ,;o+
COMMENTS
l,
ENGINEER'S CERTIFICATION
Building foundation ~.o+
Surface water
Wells on adjacent lots ~.oo+
I certify that I have determined through fi~ld inspections and
· review of Municipal records that the abo~e systems are in
conformance with MOA C0S~4 guidelines in ~ffect on this date.
Steven R. Pannomej P.E.
Engineer's Printed Name
Date
COSA Fee $
Date of Payment
Receipt Number
(Rev. 11/05)
Water main ~.o+
Driveway, parking/vehicle storage ~o+
OF 4/
Waiver Fee $
Oate of Payment
Receipt Number
ADVANCED WASTEWATER TREATMENT SYSTEM MAINTENANCE AND
REPAIR AGREEMENT
MEMORANDUM OF UNDERSTANDING
BETW~EEN MUNICIPALITY OF ANCHORAGE
THIS MEMORANDUM OF UNDERSTANDING made and entered into as of this
30 Day of Mo,~,~nlo,~r of 20..i\ , by and between
herein the "OWNER," and the Municipality of Anchorage, herein the
"MUNICIPALITY." In consideration of the mutual covenants contained herein, the
parties to this Memorandum of Understanding agree as follows:
1. ADVANCED WASTEWATER TREATMENT SYSTEMS. Municipality
grants permission to Owner to utilize and operate an Advanced Wastewater
Trealment System (AWWTS), described as I- ~). ~. ~.
at ZZTq7
Definitions.
located
, Anchorage, Alaska.
A. Alteration. Any change to the design or function of an AWWTS that
Includes the installation or removal of any pans, components or pieces not
included in the original construction permit and design. Prior to
performing any alterations to an AWWTS the owner must obtain a
Wastewater Disposal System Construction Permit from the Municipality
pursuant to Anchorage Municipal Code (hereinafter, "AMC") 15.65.
B. Certificate of On-Site Systems Approval. An approval by the
Municipality of existing water and wastewater disposal systeras given at
the time of property sale and title transfer in accordance with AMC 15.65.
3. Fee. Owner shall pay to Municipality an annual fee of
($ t~ .00), payable on or before the issuance of the operating permit and annually
thereafter. The annual fee is due on or before the anniversary date of the approval by the
Municipality of installed system.
4. Term. The term of this Memorandum of Understanding shall be for the life of the
AWWTS.
These approvals certify that the systems are adequate for the homes that
they support and meet the c. odes that were in place at the time of system
construction.
C. Damage. Any man-made or natural change in a system that would inhibit
the system from performing as designed.
D. Maintenance and Repair. The scheduled and as needed replacement of
existing parts, components and pieces of an AWWTS that were included in
the original design which would allow the AWWTS to continue to
perform as designed.
E. Permit (Coastraetior,) An On-Site Wastewater Disposal System
Construction Permit as defined by AMC 15.65.
F. Permit (Operating) An Advanced Wastewater Treatment System
Operating Permit. An annual permit, issued by the Municipality, that
allows the Owner to operate an AWWTS, upon meeting all the
requirements of this agreement, the conditions of Operating Permit, the
requirements of the On-Site Wastewater System Construction Permit and
all relevant provisions of AMC 15.65
Thc term begins on the date of approval by the Municipality of the installed system and
shall continue while the AWWTS system is in use or operational or until the property is
sold or title is transferred by owner and a new certificate of On-Site approval is issued to
the new owner or transferee of the property.
5. Alterations, Installation and...R, emoval of Additional Eauit~ment. Owner agrees
not to make any alterations, removal of parts or additions to the AWWTS without a
Conslruction Permit from the Municipality.
6. Maintenance and Repairs.
A. Throughout the term of this Memorandum of Understanding, the Owner shall
maintain AWWTS in good repair. In addition, it shall be the responsibility of the
Owner during the term of this Memorandum of Understanding, and any extensions or
renewals thereof, at the owner's sole expense, to pay for any and all: (1) repair(s), (2)
maintenance, (3) adjustment(s), (4) replacement costs, and (5) inspection costs.
Further, Owner agrees to comply will all applicable ordinance, laws, regulations,
roles and orders for the AWWTS.
B. Owner agrees to provide the Municipality a written schedule of routine
maintenance and repairs which have been performed on the system pursuant to the
t~mns and conditions contained in the Owner's AWWTS Operating Permit. This
schedule shall be submitted to the Municipality annually upon the renewal of the
permit. The schedule of maintenance and repair contained in the Owner's AWAVTS
Operating Permit is: ~:~]- ~4}/l/t}rt}~ £ y
C. Owner acknowledges that the fmc schedule for failing to maintain and repair an
AWWTS are codified in AMC 14.60.
D. Owner agrees that only maintenance, repair personnel certified by lhe
Municipality will inspect and make any necessary maintenance, repairs or permitted
alterations to the system.
E. Owner agrees to grant the Municipality reasonable access to test and inspect the
AWWTS upon 24 hours written notice.
F. Owner agrees that any sale or transfer of ti(lc of the property will not occur
without a new Certificate of On-Site Systems Approval.
G. Owner agrees that the relevant provisions of the standard specification guidebook
for AWWTS is the governing professional guidelines for the construction,
maintenance and repair of the Owner's AWWTS.
7. Nonwaiver. The failure of either party at any time to enforce a provision of this
Memorandum of Understanding shall in no way constitute a waiver of the provisions,
nor in any' way effect the validity of the Memorandum of Understanding or any part
hereof, or the right of such party thereafter to enforce each and every provision
hereof.
8. Amendment.
A. This Memorandum of Understanding shall only be amended, modified or changed
by a writing, executed by authorized representatives of the parties, with the same
formality of this Memorandum of Understanding was executed and such writing shall
be attached to this Memorandum of Understanding as an amendment.
B. For the purposes of any amendment modification or change to the terms and
conditions of this contract, the only authorized representatives of the parties are:
Owner: A&~;~,,,_ ~o. ~l~_~r
Anchorage: Purch.asing Officer
C. Any attempt to amend, modify, or change this contract by either an
unauthorized representative or unauthorized means shall be void.
9. Jurisdiction: Choice of Law. Any civil action arising from this Memorandum of
Understanding shall bc brought in thc Superior Court for the Third Judicial District of the
State of Alaska at Anchorage. The laws of the State of Alaska shall govern the rights and
obligations of thc parties under this Memorandum of Undemanding.
I0. Severabilitv. Any provisions of this Memorandum of Undemanding decreed
invalid by a court of competent jurisdiction shall not invalidate the remaining provisions
of the Memorandum of Understanding.
OWNER:
Title:
Date: ll-~O - ~[. Date:
STATE OF ALASKA )
THIRD JUDICIAL DISTRICT )
MUNICIPALITY:
The fomgoinginstmment was acknowledged before me this 30 day of l~/t2~ ,
~ My Commission expires:
BONNIE COAST L
Municipality of Anchorage
Development Services Department
Building Safety Division
On-Site Water and Wastewater Program
4700 South Bragaw St.
P.O. Box 196650 Anchorage, AK 99519-6650
www.ci.anchorage.ak.us
(907) 343-7904
CERTIFICATE OF HEALTH AUTHORITY APPROVAL
FOR A SINGLE FAMILY DWELLING
Parcel I.D. 051-741-03
GENERAL INFORMATION
Corn plete legal description r,o t
Location (site address or directions)
Current Property owner('~)
Mailing add~:es$1, ~:~
Expiration Date:
/
20; Block 4; Nort~oods
22747 McManus Dr,
Ron Thomas
PO Box 670108 Chugiak,
Subdivision
Dayphone 688-9213
AK 99567
Lending agency
Day phone
Mailing address
Real Estate Agent
Day phone
Mailing Address
Unless otherwise requested, HAA will be held by DSD for pickup.
2. NUMBEROF BEDROOMS: 4
3. TYPE OF WATER SUPPLY:
Individual Well
Individual Water Storage
Community Class__
Public Water System
Well
TYPE OF WASTEWATER DISPOSAL:
[] Individual On-site
[] Individual Holding tank
[] Community On-site
[] Public Sewer
The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of Health Authority
Approval (HAA) based only upon the representations given in paragraph 4 by an independent professional civil
engineer registered in the State of Alaska. Certificates of Health Authority Approval are required for the transfer of
title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water
supply system. DSD also issues HAAs upon request to homeowners. Certificates of Health Authority Approval are
valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with
new water sample results. (Certificates may be reissued for a period of up to one year with valid water samples,)
Certificates are valid for one year for properties served by Class A or B wells or a public water system. The
Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work.
4. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my i~vestigation,
based on procedures outlined in the Health Authority Approval Guidelines for this application, shows that the on-
site water supply and/or wastewater disposal system is(are) safe, functional and adequate for the number of
bedrooms and type of structure indicated herein. I fudher verify that based on the information obtained from the
Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or
wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances,
and regulations in effect at the time of installation.
NameofFirm S & S Engineering
Address 17034 N. Eagle River Loop Ste.
Engineer's Printed Name Robert
DSD SIGNATURE
V'~ Approved for J-~
Disapproved.
Conditional approval for
bedrooms.
Phone 694-2979
204 Eagle ,River, AK 99577
Date ~/$¥4~
bedrooms, with the following stipulations:
Additional Comments
Attachments:
HAA Checklist
Septic System Advisory
Well Flow Advisory
(Rev. 01102)
X
Maintenance Agreements : ,
Supplemental Engineer's Report
Other
Original Certificate Date: ~ - ,,~-..~ ~ ~:) /-~
Deyelopment S ~.~.!~e~s..~D~e p a r t men'"'~' ~'f- ;~
~iroand) !n.
· g.p.m.
..... g.p.m
Date of sample;
Collected by:
Clea
ft.
ft.
:~I~O ft~ Mo,n. it~r, ipg tube __ Depression gver,..fi~!,d
F?? ~ bedrooms- .
Water added ~(~ gal New depth 6' n
in. Absorption rate >=
Size in gallons ~ I '~O Manhole/Access (~N)
"Pump off" level at ~ in. High water alarm ~evela[ Z/z~'" in
Cycles tested ,~. Meets alarm & circuit requirements? ',/~;_'~
c sewer main
line
On adjacent lots
acent lots
Public sewer manhole/cleanout
Holding tank __
aln .i0 ~-
adjacent lots
_ Water service line
/0
Absorption field
Surface water
Building foundation Ilo Water main [~ ~4-
Surface water /~'+ ~ Driveway, parking/vehicle storage
Wells on adjacent lots 200 ~
;'i'.:: ~;' :i,:
through field inSPections'and
that the above systems are in
with MOA HAA guidelines in effect on this date.
CE -8801
Waiver Fee $.
Date of Payment
Receipt Number
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH & HUMAN SERVICES
Division of Environmental Services
On-Site Services Section
P.O. Box 196650 Anchorage, Alaska 99519-6650
343-4744
Parcel I.D. #
051-741-03
CERTIFICATE OF HEALTH AUTHORITY
APPROVAL FOR A SINGLE FAMILY DWELLING
1. GENERAL INFORMATION
Complete legal description
Lot 20, Block 4, Northwoods S/D
Location (site address or directions) NHN McManus Drive
Pro perty owner
Mailing address
Lending agency
Mailing address
Ron & Shelly Thomas
Day phoneTarget 694-2388
Day phone
Agent Tarqet Realty/Dick Brown
Addressp~ Rn~ 774627, Eagle River, AK 99577
Unless otherwise requested, HAA will be held for pickup.
4
NUMBER OF BEDROOMS:
Day phone 694-2388
TYPE OF WATER SUPPLY:
Individual well
Community well
Public water
NOTE:
If community well system, provide written confirmation from State ADEC attest-
lng to the legality and status of system.
4. TYPE oF WASTEWATER DISPOSAL:
XXX
Individual on-site
Holding tank
Community on-site
Pub lic sewer
NOTE:;;:,~If com~ity wastewater system, provide written
confirmation
from
State
ADEC
attesting to the legality and status of system.
72-025 [Rev, 1/91) Front MOA#21
STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my
investigation of this Health Authority Approval application shows that the on-site water supply
and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms
and type of structure indicated herein. I further verify that based on the information obtained from
the Municipality of Anchorage files and from my investigation and inspection, the on-site water
supply and/or wastewater disposal system is in compliance with all Municipal and State codes,
ordinances, and regulations in effect on the date of this inspection.
Name of Firm
Address
Engineer's signature
$ & S ENGINEERING
Eagle River, Alaska 995?7
Phone
Date
DHHS SIGNATURE
Approved for ~
Disapproved.
Conditional approval for
bedrooms.
bedrooms, with the following stipulations:
Additional Comments
The Municipality of Anchorage Department of Health and Human Services (DHHS) issues Health Authority
Approval Certificates based only upon the representations given in paragraph 5 above by an independent
professional engineer registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes
and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHH$ do not
conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not
responsible for errors or omissions in the professional engineer's work.
72-025{R~v:1/91) Back VlOA~21
!'" CEIYED
' Municipality of Anchorage dAN 2_
- DEPARTMENT oF HEALTH & HUMAN SERVICES
., EnVir,o.nmental services DiviSion.
825 L Street, Room 502 Anchorage; Alaska 99501 , (907) 343-
Legal Description:
A. WELL DATA
Well type
Log present (Y/N)
Total dePth
Health Authority ApProval Checklist
St, K. ~' /v0£r~ k~o~a$ Parcel I.D.: O ,¢'-1 - 7¥/-o
If A, B, or C, attach ADEC letter. ADEC water system number
Date completed;
CaCed to
Sanitary seal (Y/N)
Date of test
Static water level
Well production
WATER SAMP~
Coliform ~
D o~[~ample:
FROM WELL LOG
~'" g.p;m.
Casing h~
Wires.~o~perly protected (Y/N)
AT INSPECTION
B. SEPTIC/HOLDING TANK DATA
Nitrate Other bacteria
Collected by:
g.p.m.
C. ABSORPTION FIELD DATA
Date installed 1 ~/ ~ / ~ ~ Soil:rating ~or ff~/bdrm)
Length 3 6" Width
Effective absorption area 3G 0
Date of adequacy test H ( ~ - ~ Results (Pas
Fluid depth in absorption field before tes~ (in.); Immediately after gal. water added (in.):
bedrooms
.. Fluisdepth (ins) Absorption rate = g.p.d.
~ast 12 months) (Y/N) If yes, give date
72-026 (Re~/. 3/96)*
Foundation cleanOut ~)'N). ¥¢~ -'( : Depression (Y/~j) h~ ~
Date of;~Pumping ~/~ '-'~ ¢ ~' Pumper --
Date installed I~1¢'t~'~ Tank size' 13o 0 Number of Compartments
~ Cleanouts {~/N).
High water alarm ~N) ~'' ~- "~-
LIFT STATION
Date installed 13~/ ~( °l ~
Manhole/Access ~/N) ¥ ~ .,,r
High water alarm level at* z.f ¢
Size in gallons
"Pump on" level at*
*Datum
"Pump off" level at* '7 ~,
Cycles tested
SEPARATION DISTANCES
SEPARATION I~ISTANCES FROM WELL ON LOT TO:
Septic/holding tank on lot
Absorption field on lot
On adja~
~ent lots
Public sewer manhole/cleanout
Public sewer main
Sew~ Lift station
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOTTO:
Foundation ~" ~ ~rproperty line ,3 5- Absorption field
Water main/service line / 0 ~ Surface water/drainage / o ~) ~ Wells on adjacent lots
SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO:
Property line ~ ~ Building foundation ) ~ Water main/service line ? ~ '~
Surface water ! O ~) -)- Driveway, parking/vehicle storage area /o
Curtain drain ~0,,~ /,~',v~-~ ,,~ Wells on adjacent tots ~ ~0
I certify that I have determined thru field inspections and review of Municipal rec~l~..8/pfffe al) ~s are
in conformance w~h ~OA H~ guidelines in effect on this date.
Signature
En-ineer's Name /~'~/ ~
' ":'",
HAAFee $ ~ ~ ' ~
Date of Payment ~/' /~'~-} ~ ~
Receipt Number /---//-/~4'--,~ (~//7/-~ ~
Waiver Fee $
Date of Payment
Receipt Number