HomeMy WebLinkAboutPIONEER ESTATES BLK 2 LT 3Pioneer Estates Block 2 Lot 3 #057 - 091 - 09 Municipality of Anchorage Page 1 of 3 DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 • Anchorage, Alaska 99519-6650 • Telephone: 343-4744 On -Site Wastewater Disposal System and/or Well Inspection Report Permit Number: .Wfl7' s PID Number* 057-09-109 Name: Corliss Kimmel Wastewater System: 0 New 0 Upgrade Address: P.O. Box 874064 Wasilla, AK ABSORPTION FIELD Phone: No. of Bedrooms: hre Te D Deep Trench XXShallow Trench 0 Bed 0 Mound 0 Other LEGAL DESCRIPTION Sail Rating: 1 • 2 Gaprsb. Ft. Total Depth frorn,original grade: 4' Lot: Block: Subdivision: 3 2 Pioneer Estates Death 10 pipe bottom Rom original grade: Ground Surface Ft, Gravel depth beneath pipe 4 Ft, Township: I Range: Section: Fill added above original grade: 2' - 4' Ft. Gravel length: 40 Ft. WELL: ZXNew 0 Upgrade Gravel width: 5 Ft. Number of lines: 1 Distance between lnes — Ft. Classification (Private. A.B.C): Private Total depth: . 1 Ft. Cased To: ; r Ft. Total absorption area: 400 sa. Ft. Pipe material: ASTM D3034 PVC Griller. M—W Drilling Date Orlled: 10/6/98 Static Water Level: 50 Ft, Installer. Hamilton Exc. Date installed: R/11-7n/g Yield: 8 GPM Pump Set at: Ft. Casing Height Above Ground: 2 Ft. _ TANK SEPARATION DISTANCES _- gSeptic 0 Holding ❑S.T.E.P. TdIfir From ii,, Aosorotion Field lilt Station Holding Tank ublic/Pnvate Sewer lines Manufactures reer Capacity in gallons: 1.,000 Number of Compartments: fan Well >1001 >100' N/A N/A N/A Material: Steel Surface Water >100' >100' N/A N/A N/A LIFT STATION - N/A Lot Line >5' > 1 0 ' N/A N/A N/A Size in gallons: 1 Manufacturer: Foundation > 5' > 1 0 ' N/A N/A N/A "Pump on" level ar: "Pump oft' level at: Nigh water alarm at: Curtain Drain None on Lot Pump Make el Model Electrical Inspections performed by: Remarks: 2" Direct Bury Insulation BENCH MARK Placed over Tank and Absorption Location and Description: Topof Finished Trench. Floor. Assumed Elevation: 1 0 0 F, • 01/3.4t°' * k-a,-Qiii) ° ° ° n ° ° ° ° x°' Inspections performed by: J • Nicodemus Dates: 1 st 8 / 1 1 / 98s^ 2nd 8/14/98 h 0 pDEB O d 081st °,0„V,,;. v °°° b ',„:. 0 O ° °00909°° `.`-r1 �1 r �'E O --t,- Department of Heal and Human Services approval Reviewed and approved by: Gi�tGt� Date. /- 7,5--? r2.)t: a.v 3,911'ACA z5 Permit No SW980255 Page 2 of 3 Municipality of Anchorage DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 u Anchorage, Alaska 99519-6650 • Telephone: 343-4744 On -Site Wastewater Disposal System and/or Well Inspection Report Legal Description: Lot 3, Block 2, Pioneer Estates PID No • 057-09-109 ROCHELLE AVL 0 WELL GRAVEL DRIVE 1 2' 1" = 30' 100' well rod./ C5 1. NO ADJACENT WELLS WITHIN 100' 12.013 A(2/91) MOA 25 LE'G iVL SI SEPTIC CLEANOUT COMPARTMENT -1 S2 SEPTIC CLEANOUT COMPARTMENT -2 C CLEANOUT M MONITOR TUBE MI C3 o "C4 1H 31 Alternate Site F�4 fF� ER 5 $ QL i* 49The %�%0 *. o 4;1;1:: ° �O^w�eFPooVT'�i VA '` �c�lNA..k. M�DEH$O 4,1314 >° e4 A B C CI 6.4' 31.6' SI 13.1' 46.1' S2 188' 51.0' C2 24 3' 56.0' C3 25.7' 57.5' C4 38.0' 69.2' MI 39.4' 69.2' M2 34.4' 473' C5 35.2' 46.2' 12.013 A(2/91) MOA 25 LE'G iVL SI SEPTIC CLEANOUT COMPARTMENT -1 S2 SEPTIC CLEANOUT COMPARTMENT -2 C CLEANOUT M MONITOR TUBE MI C3 o "C4 1H 31 Alternate Site F�4 fF� ER 5 $ QL i* 49The %�%0 *. o 4;1;1:: ° �O^w�eFPooVT'�i VA '` �c�lNA..k. M�DEH$O 4,1314 >° e4 Permit No. SW980255 3 Page of 3 Municipality of Anchorage DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 • Anchorage, Alaska 99519-6650 • Telephone: 343-4744 On -Site Wastewater Disposal System and/or Well Inspection Report Legal Description: Lot 3, 'Block 2, Pioneer Estates PID No • 057-09-109 PROFILE LOT 3. BLOCK 2. PIONEER ESTATE'S C1/ EL =102.1 EL=99.3 SI 52/C3 C4 M/T TYPICAL TYPICAL 1 MIN COVER Vi 2' INSVLAIION BOARD. NEW 1000 GAL. TWO COMPARTMENT SEPTIC TANK with 2" Insulation EL =96.1 EL=91 EL=84.1 EL=98.6 C4 MI SE'CTIOIV 010 SCALE CAPPED MONITOR TUBE FILTER FABRI C 4 MIN COVER Vi 2' M2 !NSIAA/I0N BOARD ORIGINAL - 2-1/2' 0IA SEPTIC ROCK NO SCALE OL GW t W Wo + �r ,v WATER 1(40') PERF. PIPE INSTALLED LEVEL TH (HOLES DOWN) GE'NE'RAL IVO INSULATION BOARD WAS INSTALLED OVER SEPTIC SYSTEM WITH 2'+ FILL FOR 4' MIN COVER. ALL PIPE 1S PVC SCHED 40 UNLESS OTHERWISE NOTED. LL'CE'ND C L52Ls1 MT CLEANOUT SEPTIC CLEANOUT COMPARTMENT I �:PTIC CLEANOUT COMPARTMENT 2 MONITOR TUBE 72-013 A (2/91) MOA 25 IMPERMEABLE 9' LAYER 10' 11' 12' BOTTOM OF HOLE M -W DRILLING, Inc. P.O. Box 110378 • 10330 Old Seward Highway (907) 349.8535 ANCHORAGE, ALASKA 99511 DRILLING LOG Well Owner CORLISS KIMMEL/THOMAS TEALLOW/GRANDPRE' DOMESTIC Use of Well Location (address of: Township, Range, Section, if known; or distance main road LOT 3, BLOCK 2, PIONEER ESTATES: EKLUTNA EKLUTNA, ALASKA Size of casing 6" Depth of Hole 260 feetCased to 184.73 feet Static water level 5° ft WOW( (below) land surface. Finish of well (check one) open end ( X ) ; Screen ( ) ; Perforated ( X ). Describe A ym perforation 72 ',T082 ' AND 102TO 1 07' :4 ROWS OF 1 "X3/8" SLOTS Well pumping test at 8-1 0 gallons per of drawdown from static level. , Date of completion 06 OCTOBER 1”8__ ( 34.0 (minute) for 72 130 ft AS BUILT NOTES:1) DRY GROUT WITH 2 SACKS OF BENTONITE GRANULES. (2) WATER FROM PERF'S RAN OU IN BEDROCK FRACTURES SO BEDROCK HOLE BACKFILLED WITH GRAVEL AND PLUGGED WITH BENTONITE CHIPS AT WELL LOG 207' TD hours with Depth in feet from ground surface 0 TO 2 2 TO 5 5 TO 20 Give details of formations penetrated, size of material, color and hardness CASING STICK UP FILL GRAVEL: BROWN, SANDY 20 TO 29 SAND: GRAVELLY, WET 29 TO 44 SAND: GRAVELLY 44 TO 66 66 TO 82 82 TO 102 102 TO SAND: GRAVELLEY, SILTY AS ABOVE: TO WET .. GRAVEL: SANDY, SILTY RECEIVED JAN 14 1999 Uo P Heaithry of �irlChor�.t1-10 & f fuman ServiceR 112 GRAVEL: SILTY, WET, DIRTY 112 TO 186 186 TO 260 TO TO TO TO BOULDER GRAVEL: SILTY, SANDY BEDROCK: GREY BLACK SILTSTONE ARGILLITE,WITII MAYBE 'a GPM FROM SPORADIC FRACTURES INA Certified Contractor N` No's, 814 913 Certificate & 1 — CUSTOMER MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND HUMAN SERVICES P.O. BOX 196650, 825 "L" STREET, ROOM 502 ANCHORAGE, ALASKA 99519-6650 ON-SITE WELL AND WASTEWATER DISPOSAL SYSTEM PERMIT PERMIT NUMBER:SW980255 DESIGN ENGINEER:ANDERSON ENGINEERING OWNER NAME:KIMMEL CORLISS OWNER ADDRESS:PO BOX 874064 WASILLA, AK 99687-4064 PARCEL ID:05709109 LEGAL DESCRIPTION: PIONEER ESTATES BLK 2 LT 3 LOT SIZE: 103200 (SQ. FT.) NUMBER OF BEDROOMS: 3 THIS PERMIT: 3 THIS PERMIT IS FOR THE CONSTRUCTION OF: DISPOSAL FIELD /SEPTIC TANK / WELL SYSTEM ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH: PAGE 1 OF 1 DATE ISSUED: 7/23/98 EXPIRATION DATE: 7/23/99 1. THE ATTACHED APPROVED DESIGN. 2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS 15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80). 3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY CALLING 343-4744 ( 24 HOURS ) . (NOT REQUIRED FOR WELL ONLY PERMIT) 4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING WEATHER MUST BE EITHER: A. OPENED AND CLOSED ON THE SAME DAY B. COVERED, SEALED AND HEATED TO PREVENT FREEZING 5. THE FOLLOWING SPECIAL PROVISIONS. SPECIAL PROVISIONS: RECEIVED BY: ISSUED BY: DATE: 1/LL /16 DATE: 7 .23 . / C) ERSON ENGINEERING P.Q. BOX 2407'73 ANCHORAGE, AK 99524 X22-'7773 X22-6779 (IFAX)' July 13, 1998 Municipality of Anchorage Department of Heath & Human Services 825 "L" Street Anchorage, AK 99502-0650 Subject: Lot 3, Block 2, Pioneer Estates Subdivision Septic System Design Impacts to Adjacent Properties Dear Onsite Services Engineer: We are hereby applying for a permit to construct a new well and septic system on Lot 3, Block 2, Pioneer Estates Subdivision. The lot is currently vacant with no development on any of the surrounding lots. The attached site plan and backup documentation identify the size and location of the new septic tank and absorption trench to serve the home. It also shows the location of the proposed well and the 100' protective radius. Testhole No. 1 which was placed near the area of the proposed absorption trench and consisted of well graded sands and gravels which percolated at a rate in excess of 1 minute per inch.. Groundwater was noted during excavation at the 8.5' level and remained at that level during the monitoring period. We are therefore proposing to construct a 5' wide trench system with 4' effective depth. Total length will be 40' with the distribution piping at the existing ground surface. Total depth of the trench will be 4'. Insulation will be placed atop the trench to protect against freezing. The surface of the lot slopes from north to south at varying rates with grades ranging from 6% to 10%. The slope in the area of the proposed absorption trench is fairly flat with a minor slope from east to west. The lot is relatively large and sufficient area exists for the placement of the new and reserve site and the well radius. No conflicts exist between the septic system area and other wells or septic systems in the area. Lot 3, Block 2, Pioneer Estates July 13, 1998 Page Two If the system is constructed as designed the following statements apply: 1. The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. 2. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. 3. The system, if constructed as designed, will have no adverse impact on reserved space, either surface or subsurface, on any lots located in the area. 4. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, Michael E. Anderson, P.E. Attachments ROCHELLE AVENUE e AI 0 Zi Sib Proposed Well Three Bedroom Home 100' Well TH2 Alternate Site 1,000 Gall.n eptic Tan 40' Long 5' Wide X ' Deep Absorp ion Tren h <' NOTE: No Wells or Septic Systems Within 200' Of The Proposed Systems. SITE PLAN SCALE 1" -. 50' LOT 3, BLOCK 2, PIONEER ESTATES SUBDIVISION DESIGN FACTORS: Three Bedroom Horne Perc. Rate: LT 1 Min./Inch Application Rate: 1.2 GPD/SF SYSTEM REQUIREMENTS: 5' Wide Trench System 1,000 Gallon Septic Tank 4' Drainfield Rock 3 Bedrooms X 150 GPD / 1.2 GPD/SF = 375 SF of Absorption Area 375 SF/5 LF (Width) X .5 (Red. Factor) = 40 LF Trench Length Therefore: Construct a 5' Wide Absorption Trench System With One Lateral 40' in Length with 4' of Drainfield Rock Beneath the Lateral. Distribution Pipe in Trench Placed at the Original Ground Surface. 5' Drainfield Rock TYPICAL WIDE TRENCH SECTION"' (NO SCALE) NOTE: Grade Area Over Trench to Drain Away. Minimum 3' of Cover over Septic System. Minimum 4' Separation From Groundwater. Minimum 10' Separation From Lot Line. kfidellAEL \ 4381- PERFORMED FOR: Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 '1.* Street, Anchorage, Alaska 99502-0650 SOILS LOG - PEFICOLAT1ON TEST _SENG.INEOSSErik,L1 ..) •.• ( < • * • ri . Gary Smith - Grand Pre Homes 40-0 °V•IA" OATE PEFIFORM,ekt__ LEGAL DESCRIPTION: Lot 3 Block 2 OL Pioneer Estates 4 - .. 8 ' • • ' • 9- 10 - 12 0 • .. - • • SoTro PA 13 - 14 - 15 - 16 - 17 - 18 - 19 - 20 - Township, Range. Section: SLOPE SITE PLAN WAS GROUND WATER ENCOUNTERED? IF YES, AT VVHAT DEPTH? E aeon to walsr Atter 6v., zz1,13.. *mitring? Date Reading Date Gross Time Net Time Death to W311! Net Dram PERCOLATION RATE > 1 (minutes/meg PERC HOLE DIAMETER 8 it TEST RUN BETWEEN 2 FT AND -a-- FT COMMENTS PERFORMED V: J NtcndP11111 11-4.4-&-C"I—CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE 72-008 (Rev. 4/85) PERFORMED FOR: Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG — PERCOLATION TEST Gary Smith - Grand Pre Homes (EN GIP„EgR'SSEAL) f�Js„ rl .: OATEPERFOPIME04-• 6/18 98. LEGAL DESCRIPTION: Lot 3 Block 2 , Township, Range, Section: OL Pioneer Estates 10 11 12 13 14 15 16 17 18 19 20 Qo't•DM of _ri-i Jo . SLOPE WAS GROUND WATER ENCOUNTERED? `ice S IF YES, AT WHAT DEPTH? 3 Depth Io water Ahern Mani aring7 pate S L 0 P 7/0/q6 SITE PLAN N Reading Cate Gross Time Net Time Depth to Water Net Drop PERCOLATION RATE > (minutesnnetlt PERC HOLE DIAMETER 8 " TEST RUN BETWEEN FT AND - FT COMMENTS Mara Than 50 of Maf-aria1 Pas S Na 4 GiPVP' PERFORMED BY• ,7 _ Ni codcpmnc ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: C. ./L/t�CBR-'flitY THAT THIS TF,ST WAS PERFORMED IN 72-008 (Rev. 4/85) ON-SITE WASTEWATER DISPOSAL SYSTEM CONSTRUCTION AND MATERIAL SPECIFICATIONS SUBJECT: LOT 3, BLOCK 2, PIONEER ESTATES SUBDIVISION GENERAL: 1. The scope of this project includes the procurement and placement of a new 1,000 gallon septic tank. It also includes the construction of a new 40' long by 5' wide by 4' effective depth absorption trench at the location shown on the site plan. The distribution piping must be placed at the original ground surface. The total depth of the trench must not exceed 4'. Direct bury insulation must be placed atop the trench along with 2' of cover as protection against freezing. 2. Construction shall be in accordance with the approved site plan, design drawings, Municipal Permit with any special provisions or conditions, and all applicable State and Municipal Wastewater Disposal Regulations. 3. The Contractor shall be responsible for obtaining all underground utility locates and for the layout of the septic system and verification of the location of all lot lines. 4. Unless specifically agreed otherwise, the contractor shall be responsible for final grading areas subsequently depressed from soil settling. Property owner shall be responsible for revegetation of affected areas unless specifically agreed otherwise. 5. Contractors installing wastewater disposal systems must be certified by the Municipal Department of Health and Human Services for system installations. Owners installing their own systems must receive prior approval from D.H.H.S. before beginning system installation. SEPTIC TANK INSTALLATION 1. A new 1,000 gallon septic tank must be procured from an approved source and installed at the location shown. Lot 3, Block 2, Pioneer Estates July 13, 1998 Page Two 2. A septic tank is to be constructed by a certified septic tank manufacturer. Construction shall include two 4" cleanouts for pumping access. 3. The septic tank shall be sufficiently bedded to prevent settling or shifting of the tank. 4. All standpipes on the septic tank shall extend a minimum o f 12 inches above final grade. 5. Tanks installed without 4' of cover shall have a minimum o f 2" of direct burial insulation. 6. A foundation cleanout shall be installed one to four feet from the building foundation. Two cleanouts are required between the tank and the drainfield. 7. Final grading over the tank shall be such that a positive slope exists away from the septic tank. DRAINFIELD CONSTRUCTION: 1. The drainfield shall be constructed to the dimensions shown on the design. The bottom of the trench shall be within 2" of level. 2. Distribution piping must be placed level with perforations down atop a level bed of drainfield rock. Rock should then be placed over the pipe to provide a minimum of 2" of cover. 3. A silt barrier or geotextile fabric must be placed between the drainfield rock and the natural soil backfill. 4. Monitor tubes must be 4" in diameter and installed at the locations shown on the design. The portion below ground must be perforated. Lot 3, Block 2, Pioneer Estates July 13, 1998 Page Three 5. Contractor shall verify the septic tank and drainfield are a minimum 100' away from any private water wells in the area, 150' from a Class "C" Well or 200' from any community well. 6. Direct bury insulation must be placed over the distribution system if less than 3' of backfill depth is available. Finish grade over the trench must be mounded to prevent settlement or depressions. 7. Grade area surrounding the absorption trenches to drain away. 8. A minimum 2' of accepting soil is required below the drainfield rock for a 5' wide trench. Contractor shall verify this condition prior to placement of the rock. All pockets of unacceptable materials must be removed and replaced. MATERIAL SPECIFICATIONS: 1. Septic tanks must be constructed by a Municipally approved septic tank manufacturer. 2. The following pipe materials are approved for use in septic system installations in the Municipality of Anchorage: Cast Iron (perforated and solid), ASTM D3034 or P.V.C. (perforated and solid), ASTM F810 or H.D.P.E. (perforated, but not solid) and ASTM D2662 or A.B.S. (perforated and solid). 3. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Co. Styrofoam HI or equal). 4. Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Fernco, or equal). Lot 3, Block 2, Pioneer Estates July 13, 1998 Page Four 5. A permeable geotextile fabric (Typar, Mirafi or equal) must be installed between the final drain rock layer and the native soil layer. 6. All drain rock shall be .5" to 2.5" in diameter with less than 3% passing the #200 sieve. INSPECTIONS: A minimum of two inspections are required by Municipal Ordinance. These inspections must be conducted under the supervision of a professional engineer registered in the State of Alaska. The first inspection must be conducted after the excavation of trenches, beds or pits and before the installation of any gravel. A septic tank may be set in place, but may not be backfilled. The second inspection must be conducted after the placement of the geotextile fabric, gravel, distribution piping, standpipes, cleanouts and insulation. No backfill should be i n place at the time of inspection. Contractor shall provide a copy of all field survey layout and construction notes for use in preparing the certified as -built of the completed system. Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. 057-091-09 1. GENERAL INFORMATION Complete legal description HAA# 65 Otto y Expiration Date: 2 ') G -o6 Lot 3; Block 2; Pioneer Estates Location (site address or directions) 38150 Rochelle Ave. Chugiak, AK 99567 Current Propertyowner(s) Corliss Kimmel n Day phone 344-8497 Mailing address (�0 1;t4,'4 G< I-NhU Qwevt NG- agSi 4 - Lending agency Day phone Mailing address Real Estate Agent Mailing Address James Riley Day phone 248-8700 2921 Pelican Dr. Anchorage, AK yAK995002 Unless otherwise requested, HAA will be held by DSD for pickup. 2. NUMBER OF BEDROOMS: 3 3. TYPE OF WATER SUPPLY: Individual Well Individual Water Storage Community Class Well Public Water System /1 //7/s,j•- TYPE OF WASTEWATER DISPOSAL: Individual On-site 7® ❑ Individual Holding tank 0 ❑ Community On-site 0 ❑ Public Sewer - 0 The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of Health Authority Approval (HAA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of Health Authority Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues HAAs upon request to homeowners. Certificates of Health Authority Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water sample results. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Health Authority Approval Guidelines for this application, shows that the on- site water supply and/or wastewater disposal system is(are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm S & S Engineering, Phone 694-2979 Address17034 N. Eagle River Loop Ste. 204 Eagle River, AK 99577 Engineer's Printed Name ORO 4.47- (1 �pwef./ Date 1/ / S /05- ,.� 15F q =ltt a 4.) .....'.4 5. DSD SIGNATURE °6 71 % aoemr t COWANit �� l/: Approved for 3 bedrooms. iteb CE•6E0I fri Disapproved. teN 1tihit,:+, .'.:1 sem. Conditional approval for bedrooms, with the following stipulations: By: Additional Comments al)OFAN1/4 ��4 J2•; • O••s WATER AND • m N -SITE WASTEWATER Attachments: HAA Checklist Septic System Advisory Well Flow Advisory X Maintenance Agreements • Supplemental Engineer's Report Other . (Rev 01/02) Original Certificate Date: 1 J 1 -06- Municipality of Anchorage Development Services Department Building Safety Division On -Site Water & Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 HEALTH AUTHORITY APPROVAL CHECKLIST Legal Description: Loi 3 Q 1, o cif a Piotife,t. Es?, A. WELL DATA Well type pa Voir If A, B, orCprovide PWSID#= Date completed IDA v Sanitary seal (5b/N) YE Total depth a CO ft. Cased to ) 4 rft. FROM WELL LOG /o (6 /iI Y Date of test • Static water level Well production CO ft. k '�O g.p.m. WATER SAMPLE RESULTS: Coliform s7 colonies/100 ml. Nitrate 0.131 mg.// l. Date of sample: /obT/os Collected by: Parcel ID: oS7— 09I — 09 Well Log t &I) ' t S Wires properly protected (ON) Yk. S Casing height (above ground) 1 W1- in. AT INSPECTION 11/a/os '7 5� y. / Other bacteria Arsenic: = mg./I. B. SEPTIC/HOLDING TANK DATA 54 -PT s c ( STE Q. Tank Type/Material Date installed ft. g.p.m. 0 colonies/100 ml. $ & S ENGINEERING 17034 Eby* Pay.r hoop Koad No. 204 Eagle River, Alaska 99577 $ /id se Tank size /000 gal. Number of Compartments 2- Cleanoutse N) iLf' Foundation cleanout &�'N) Yes Depression over tank (Y6 ✓0 High water alarm (Ye r0 Date of pumping ‘k -1 12.001- Pumper J%s S Loc -4/0) C. ABSORPTION FIELD DATA Date installed viiiim %r Soil rating •.d./ft2 •r ft2/bdrm) )_a System type T R EN c N Length 4 O ft. Width ft. Gravel below pipe i/ Total depth 7 ft. Eff. absorption area Date of adequacy test 1, �a f° S Results Fail) r4 -5J Fluid depth in absorption field before test 0 in. Elapsed Time: 11 min. Final fluid depth y!0 ft2 Monitoring tube YE -5 Depression over field ow o For 3 bedrooms Water addedg i0gal. New depth S in. O in. Absorption rate >= A%SO g.p.d. ft. Any rejuvenation treatment (past 12 mo.) (Y/N & type) a * s KNOW.✓ If yes, give date r D. LIFT STATION Date installed Size in gallons 'Pump on level at _ in. "Pump off' level at _ in Datum -sed E. S PARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot )0 0 f On adjacent lots Absorption field on lot /0 4 f On adjacent lots Public sewer main H lA Sewer /septic service line a-5- (÷ Manhole/Access (Y/N water alarm level at Meets alarm & circuit requirements? %00 rf in. Ji o -� Public sewer manhole/cleanout A/ Holding tank N l A SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: 1 Building foundation C 4- Property line ' t Absorption field S f r Water main » /4 Water service line /0 t Surface water / 0 0 et Wells on adjacent lots per 4 - SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Building foundation /0 r">A Water main Y 14 / 0 0 I+ Driveway, parkinglvehicle storage CO 14 - Property Property line /0 i r Water Service line ft' l- Surface water Curtain drain N eN li. kNcwrr Wells on adjacent lots /00 F. COMMENTS G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA HAA guidelines in effect on this date. Engineer's Printed Name Ra a EAT C. Cbis4 d Date f / 210.1- HAA /°r .15"- OF At Qi .r '.F ............^I r ,C )", r'.t; HAA Fee $ 430 41) Date of Payment I t fI L1 i05 Receipt Number q(0(0 Clen (Rev. 12/01) Waiver Fee $ Date of Payment Receipt Number LEGEND: MEASURED DATA Q•s' RECORD DATA N 90'00'00" W RECOVERED l'i' REBAR 0 CLEAN OUT 0 M ROCHELLE AVE N 89'55'30" E 258.00' 1 ttLL \: 7 GRAVEL DRIVE r' LOT 2 v 10W.ITY EASEMEAT w 0 O 0 O O z 0 f") 1 STORY WOOD HOUSE W/ DAYLIGHT BASEMENT f4' EAVE TYPICAL) CONrt LOT 3 103,200 sq.ft. RECERTIFICATION THIS IS A RECERTIFICATION OF AN MORTGAGE SURVEY DONE BY THIS COMPANY ON SEPTEMBER 11, 1998. O O LOT 4 N 00604'00" E