Loading...
HomeMy WebLinkAboutPOLLOCK HOMESTEAD BLK 1 LT 2 ((4 ~ MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION .... ENVIRONMENTAL ENGINEERING DIVISION ' 825 LStreet-Anchorage, Alaska 99501 Telephone 264-4720 ON-SITE! SEWAGE DISPOSAL SYSTEM AND/OR WEI.L INSPECTION REPORT MAILING AD r/~ LEGAL DESCRIPTION LOCATION DISTANCE TO: Manufacturer ' Absorption area We, /0 Liq. in(~gallons IF HOMEMADE: WelI DISTANCE TO: TWell , c DISTANCE TO: / LO ,~ No, of lines /Length of each line- Top of tile to finish grade ~ Length Width Insidelength Dwelling - -' --[ Mat6¢ial Foundation.4~ ~¢ Nearest lot line Total length of lines ~ /Trer24;b wicJlt~ Material beneath tile Depth NO, OF BEDROOMS PERMIT NO, (')o<-(o! No, of co..m, partments Liquid dep._t h~_ ~ PERMIT NO. Liq-u~'d capaoity imgallofi~ .... PERMIT NO. Total effective ~bsorption area PERMIT NO. Type of crib Crib diameter Crib depth Total effective absol'ption area Well Building foundation Nearest lot line DISTANCE TO: Class Depth Driller Distance to lot line PERMIT NO. DISTANCE TO: Building foundation Sewer line Septic tank Absorption area(s) OTHER PIPE MATERIAL~ ~ SOl L'~EST RATING .~_.~ ~ REMARKS DATE / LEGAL 72-013 (Pt(~, 3/78) FIPF'LICF:tNT JUNE .ZIGF~FINO SRR BO?, 4,'7'rS-Z L. OCFITI ON RF. IE:E:IT CREEK ROFID [...[CC~F:IL 'L2 B'I POLLOCK LOT SIZE T'¢F'E OF SOIL FIBSORF'TION S'¢S'f'EH IS: TRENCH MRXIMLff"I NUHBER OF BEE:,ROOMS = :'".:: SOIL. RRTING (21r:~ FT,.-'BF.'..'. .... 'f'HE REQL.IIREE:, SIZE OF: THE SOIL RBSORF'TION S'¢STEH IS: ~44.--7Z:24 .'LE:::I. 840 SQURRE FEET ': ..... THE LENGTH [:,IMEN'-T, ION IS THE LENGTH (IN FEET.'., OF' THE TF.:ENC:H OF.: DRRINFIEL. F.h THE DEPTH OF R TRENCH OR PIT IS THE DISTFINCE BETHEEN THE SURFFtCE OF THE GROUND RN[:, THE BOTTOrd OF THE ENCRVRTION ,:.'IN FEET::,. THEF.:E IS NO SET HI[:,TH FOR TRENCHES. THE GRR',,,'EL. DEPTH IS THE MINIHtJM DEPTH OF GF.'.R',,,'EL BETHEEN THE OUTFRLL PIPE FIND THE E:OTTOH OF THE Eh':C:R'v'RTION ,','IN FEET). F'ERI'iIT FIF'PLICRNT FIRS THE RESF'ONSIBILIT'¢ TO INFORM THIS DEPRRTHENT DLIRING THE INSTFIL. LFITION INSPECTIONS OF Fff',l"r' HELLS RC.'..TIBCENT TO THIS PROPERTY FIND THE 1'4Uf'iBER OF RESIDENCE:i~, TFII:I'r THE HELL. HILL SERVE. ' .................. ]"l..,.l(L'i ,:.' ~: .":, Z ['-4 :E; F" E C -r ][ Ol'-,IF_; RF.:E F.:EE:-:!L! ][ 1:3F~C:KFILL. ING OF RN'¢ S'¢S"['EM 1.4ITHOUT FINRL INSPECTION RND FiPPRO'¢RL. D'¢ 'f't4IS DEPFtRTP1ENT HIL. L BE .SUB..TEC:T TO PROSECUTION. MINIMUH DI:.-];'rI-~NCE BE'THEEN R HELL taN[.., RN¥ ON-SITE ~,EHFIGE DISF'OSFIL '..T,'T'S'I'EM IS :D..30 FEET F'OR FI PRIVRTE HELL OF.'. t50 TO 200 FEET FROH R PUBLIC HELL DE:PENDING UPON THE T'¢F'E OF PUE:LIC [,.IEt.L. HINII"'IUH [:,ISTFINCE FROM R PF.'.IVRTE HELL TO R PRIVRTE SEHFF.'. LINE IS 25 FEE'[' RND 'FO FI COHPtUNIT'T' SEI.,.IEF.: LINE IS 75 FEET. OTHER F.:EC¢..IIF..".EfdENTS [IFI'T' RPF'L't'. SPECIF'ICRTIONS RND CONS]"RUCTION DIRGF.:RM2; FIRE R',/RIL. RBLE TO INSURE PROPER INSTRLLRTION. I C:ERTIF'T' THFIT /L: I Fir1 FFIP'IILIRR 1.4ITH THE REQUIREMENTS FOR ON-SITE SEHE:RS RND HELLS RS SET FORTH E:'t' ]'HE HUNIC:IF:'RL.I'r".r' OF RNC:HORFIGE. 2: :[ HILL INSTFILL THE S'¢S'rEH IN I-']E:COR[.',RNC:E HiTH THE CODES. -.::: I UNDEF.:S]'FIN[:, THRT THE ON-SITE SEHER S'¢STEH r,lR'¢ REL.".!UIRE ENLRRGEMENT IF: THE RESI[:,ENC:E I'-] F.:EHO[:,ELE[:, TO INCLUDE FIORE THRN ~ BEDROOMS. ',,,'4. 0 ~] SOILS LOG MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION ~ PERCOLATION TEST Pouch C--GE0, Anchorage, Alaska 99502 '276-222~ SOILS LOG -- PERCOLATION TEST AST NO 01180 PERFORMED FOR: .]ack Hill Excavaf. J]nq CDr June ZiuraRUDATEPERFORMED: 8/12/80 (Owner) LEGAL DESCmPT~ON: Lot 2, Block 1, Pollock Subidivision 1 2 3 4 ~5 6 7 8 lo ~2 14 16 '17 2O COMMENTS SLOPE SITE PLAN Sandy Gravel w/cobbles 7 boulders to 24" Dry Brown, Dry ~lL~w/som~ gravel bray, ury od F~ame iF YES, AT WHAT T. D. DEPTH? See Comments) Reading Date Gross Net Depth to. Net Time Time, FI]iR Water, :~n Drop~ in 1 8/12/8[ 3:48 -0- 5,5 -0- 2 8/12/8 3:50 2 6.8 1.3 3 8/12/8 3:52 2 8.0 I .z 4 8/12/8 3:53 -0- 3.8 -0- 5 8/12/8 3:55 2 5.5 1 .7 6 8/12/8 3:57 2 6.9 I .4 PERCOLATION RATE 2rain/inch (minutes/inch) TEST RUN BETWEEN 4 FT AND 5 FT Water Seep at the 9' level only. PERFORMED BY: S~:ephen D. Shrader 72-008 (7/76) CERTiFiEDBy:S, Shrader, P.E. DATE: 8/12/80 Alaska Soils Investigations 624 W. In~'l Airport Rd. Suite 103 Anchorage, AK