Loading...
HomeMy WebLinkAboutRABBIT CREEK VIEW & HEIGHTS BLK 4H LT 19APermit Number:OSP251416 Tax Code Number:02055133000 Work Type:Septic Upgrade Effective Date: Design Engineer: Site Legal Address:RABBIT CREEK VIEW & HEIGHTS BLK 4H LT 19A G:3340 Owner:DAVIDSON DEAN Site Mailing Address:7841 BYRON DR, Anchorage Lot Size in Sq Ft:19964 Total Bedrooms:3 This permit is for the construction of: Disposal Field Septic Tank Holding Tank Privy Non-Public Water Well Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Coodinate with On-Site staff regarding preferred method. 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing 11/26/2025 11/26/2026 FIRST WATER CONSULTING Expiration Date: þ ¨¨¨¨¨ Issued To: Issued By: Date: Date: 11/26/2025 11/26/2025 FIRST WATER CONSULTING Isatou B Njie MUNICIPALITY OF ANCHORAGE On-Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite On-Site Wastewater Disposal System Permit 13030 Sues Way, Anchorage, AK 99516 907-350-9566 / firstwaterAK@gmail.com ! !! November 25, 2025 Municipalities of Anchorage On-Site Water & Wastewater Program 4700 Elmore Road Anchorage, AK 99507 RE: SEPTIC SYSTEM UPGRADE PERMIT LEGAL: RABBIT CREEK VIEW & HEIGHTS BLOCK 4H, LOT 19A The property owner has requested we obtain a permit to upgrade the failed septic field of the above referenced lot. We propose to remove any biomat material, add MOA sand to maintain elevations to the existing 2 trenches, reinstall these 2 trenches along with 2 new trenches to serve the existing 3-bedroom residence. The design is based on the recent test hole conducted in November 2025 & the existing test hole conducted by Steve Pannone, PE in October 2014. No groundwater was observed at test hole excavation of TH25-1 but was monitored at 10.5’ a week later. However, the 2014 test hole monitored groundwater that October at 7.5’ and this monitored observation has been used in the design. At time of design, it was found that the existing septic tank is approximately 95.5’ from the referenced well. The immediate area does not have a high nitrates and the attached CAN water samples show nitrates at 0.637 mg/L. The referenced well is significantly up gradient from the septic tank, there have been no known issues and the area well logs indicted a confining, protective layer of silt. For these reasons, a waiver is justified, but at this current time a waiver is not requested till after the integrity of the tank is verified at construction – please see design note. Also, it was found that the well appears to be in the Byron Drive ROW. A different surveyor is verifying and if need be, the owner will contact MOA ROW to resolve. This issue does not affect the issuance of the septic upgrade permit. The slopes are 17-22% at the proposed upgrade location. The lot and area are served by private water. The design will not impact any of the neighboring properties. Please contact us if you have any questions. Sincerely, Curtis Huffman, P.E. Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP251416, Isatou Njie, 11/26/25 3030 Sues Way - Anchorage, Alaska 99516 Tel. 907-350-9566 firstwaterAK@gmail.com SOILS LOG - PERCOLATION TEST LEGAL : RABBIT CREEK VIEW & HEIGHTS BLOCK 4H, LOT 19A PERFORMED BY: FWC - I CURTIS HUFFMAN CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE & MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: 11/12/2025. DEPTH FEET OG SOILS 1 2 ORG/OL-FILL 3 4 5 6 GM/ml 7 8 9 10 11 12 13 14 15 BOH 16 17 18 19 20 Reading Date Gross Time Net Time Depth to Water Net Drop 11/06/25 30 min 6” 13 /16” “ 6” 13 /16” “ 6” 13 /16” PERCOLATION RATE 37 (MIN / INCH) TEST RUN BEWTWEEN 4 & 5 FT PERC HOLE DIAMETER 6” PRE-SOAKED PRIOR TO TEST & ALL READINGS TO THE 1/16TH. GROUND WATER ENCOUNTERED: NO IF YES, AT WHAT DEPTH: YES DEPTH TO WATER AT MONITORING: 10.5’ DATE: 11/12/2025 TESTHOLE # 25-1 DATE PERFORMED: 11/05/25 SEE SITE PLAN FOR SLOPE & LOCATION COMMENTS: Pannone 10/22/2014 TH-1 monitored groundwater at 7.5’ VERIFY GROUNDWATER MT AT TIME OF CONSTRUCTION PERFORMED FOR: DEAN DAVIDSON 11/12/25 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP251416, Isatou Njie, 11/26/25 FIRST WATER CONSULTING RABBIT CREEK VW & HTS B4H, L19A DESIGN CALCS: NO SLOPES >25% WITHIN 50' OF PROPOSED FIELD. STAKE PROPERTY LINES, WELL RADII, ESMTS, OR OTHER SEPARATIONS... PRIOR TO CONST. Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP251416, Isatou Njie, 11/26/25 FIRST WATER CONSULTING NO WELLS WITHIN 100' OF PROPOSED SEPTIC FIELDS. DESIGN DETAILS: RABBIT CREEK VW & HTS B4H, L19A Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP251416, Isatou Njie, 11/26/25 MUNICIPALITY OF ANCHORAGE DE 1TMENT OF HEALTH AND HUMAN SER' iS Environmental Health Division 825 "L" Street, Anchorage, Alaska 99502, Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Aurora Contractors 2901 Rose, Anchorage Alaska 99516 Phonets} 561-6611 850110 3 LEGAL DESCRIP~rlON Lot [- Bio TSubd,vls~on 19 ~ ~ '~ I Rabbit CK Hei§h~s i1N ~' TANKS F,~ SEPTIC [~ HOLDING Greer 1000 Gallons Ma,e.~,,Steel TYPE OF SYSTEI~I ~'FRENCH [] BED [] W. DRAIN [] OTHER 3.5 FT 7.5 i FT 3.5 14.8 )z-~'J~O(,.-~t" J~o SO FI 10 FT 2J 445 SO FT 3034 PVC ~,urora Contractor 7-19-85 WI=LL$ ~ PRIVATE [] OTHER (Identifv) C~assd,cat,on iA ~.C, ~otai ~u(~H] ] Cased to C I:T 180 FT ;4[,; ~rilling 6-14-85 REMARKS: DISTANCES SEPTIC TANK WELL LOT LINE FOUNDATION 105 ft 22.5 'Ft 2~. 7 ft ABSORPTION FIELD WELL 104 'Ft 10 ft 2.5 ft 40.8 ft 30.2 ft AS-BUILT DIAGRAM tShow Iocahol] of well. septic system, properly hr/es, foundation. Scale: ~O =- I't Inspechons Pet~or~.ed by Date 7-22-85 , /'~¢£~'~ .~Z~L~-~_~ ___~ __ cerlil¥ thai ,his inspeolion was ped0rmed acc0rdi.0 to all MunicipoI and Slate guideIines in ellecl on this dafe: Health Department Approval: 72 013 (3/85) MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION 825 L, Street, Anchorage, Alaska 99501 264-4720 SOILS LOG -- PERCOLATION TEST [] SOILS LOG PERCOLATION TEST PERFORMED FOR: Lionel Urban DATE PERFORMED: 4/1_7/85 LEGAL DESCRIPTION: Lot 19 Block 4 1 ~ ?ibrous ..1 1/1 Brown Peat Pelc Zone 2 3 4 5 6 7 8 9 10 11 12 13 -- 14 15 16 17 18 19 2O COMMENTS Rabbit Creek Heights Brown SiltZ Sandy Gravel (OM) with occasional cobbles SLOPE SITE PLAN Water Seepage WASGROUND WATER ENCOUNTERED? Yes IF YES, AT WHAT DEPTH? 131 Reading Date Time 6. ~ca±e bu' ,per ;~quare Net Depth to Net Time Water Drop No 24 hfs Satura io Perio Waber ~,.¢/,,..¢; .......;-.,~,.~. ~/~7/U5 0 hrs 1 1/2" '~ .' L~,~aoi~,,,o~.~ ~ i 4 0 hrs~ 5 1/2" 1/2' ~.--~%,, .... , i¢~ERCOLATION RATE 60 ,mn pe~ ~noh (mmuteshnch) (~Y'&~:~ TEST RUN BETWEEN , ~ , FT AND ,~ FT / 32~ square feet of drainage area required per bedroom / PERFORMEDBY: NPC CERTIFIED BY: Alaska Test Lab DATE: 4/17/8g 72-008 (6/79) FV1-W DRILLING, Inc. P.O. Box 10-378 · 10300 Old Seward Highway (907) 349-e~3s ANCHORAGE, ALASKA 99511 85-189 DRILLING LOG Well Owner A~ror~ C~n~-r~rtL.ion _Use of We]l Dc~m - Location (address of: Township, Range, Section, if known; or distance main road L19, B4, Rabbit Creek Hts., Anchorage Size of casing 6" Depth of Hole 180 feet 4"---160-180 Casedto 6"=162.9 feet Static water level Screen ( ); Perforated ( X ), Describe screen or perforation 4" perforated liner,./~0/-/~>0 / Well pumping test at 2 gallons per (hRRr) (minute) for 4 ' hours with of drawdown from static level. 30 ft. (~) (below) land surface. Finish of well (check one) open end ( 100% ); Date of completion 20 June 1985 WELL LOG Depth in feet from ~ ground surface Give details of formations penetrated, size of material, color and hardness 2 TO 6 6 TO TO TO TO_ __TO. TO_ ~TO. TO __.TO. .TO. ____.TO. ,TO. 40 40 53 53 60 60 80 80 100 100 125 125 140 140 180 Clayey Gravel Coarse 8ravel;cobbl% Boulder grave]. Cobble. gKa. vel; wet Tight gravely hard_pan Cl'ay Clayey gravel $Iave]? clay Grava]y hard?~n; wntmr mm~p~ ~n mmmll grmvml ~rdngmrm 1 -- Cus'rOMER 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. In conducting an adequacy test, I attempt to provide a thorough, conscientious engineering analysis of the system in accordance with MoA COSA guidelines and regulations. The reported results describe the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readily identifiable features. The operational life of all wells and septic systems depend on the local soil condition, ground water levels that may fluctuate during the year, and the water usage of the family being served by the system. These conditions are outside the control of the evaluator of this system. All systems eventually fail and satisfactory test results do not guarantee future performance of the system, nor do they guarantee that there are no hidden defects or encroachments. Therefore we cannot provide any warranty for future performance, nor can we estimate remaining life of the system. The content of this report is for the sole benefit of the owner listed above. Name of Firm Pannone Engineering Services LLC Phone (907) 272-8218 Address P.O. Box 100217, Anchorage Ak. 99510 Engineer's Printed Name Steven R Pannone 6. DSD SIGNATURE 2I \ I\1` XSystem #1 Approved for 3 bedrooms v System #2 Approved for bedrooms Disapproved Conditional approval for 3 bedroon Date 11/10/2014 iJc,4,t� t?F Al.,q`S''�� .j Seven R.•Pannone ,• CE -8149 AW Amw with the following stipulations: Zrts�2C- ori ne-PR+/jue rd &-oL0,1"V Peru \\�`�� 9Fttrr►rn,f(61,/ z 0 -- A D �-S \A h, CqJ PROG YX FAIr cFR ..� gy Original Certificate Date: R/�'t� ,9 The unicipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA blue sheet � 1. B'IUNICIPALI'f¥ OF ANCf4OEtAGE DEPARTMENT OF I-tEAt..'i"I-t AND ENVIRO~IIS'IENTAL PROTEC¥1ON DiVISiON OF ~:;NVlt';IONBIENYAL CEFiTIFICATE Of-INSPECFION FOR HEAl_TIt AUrFHORITY APPROVAl. (.)F ON-SITE SEWEI-I AND WA't-ER FACILITY 264-4720 Application Date ._ ¢¢ Et',MI.iA ~ ii',]t:'O R t¥1A'fl C'N Ca) Legal Description (include lot, bloc;l(, subdivision, section, township, range) Location (address or di~ecbons~ Applica'nt Address ,-' ~ , ~'- Cc) Applicant is (check o¢~e): Lending institution Cd) .endinq Institution ~_ _~. ~ __~Z.~. ~;.:;~_;_ ~f~; ' '" Teiophono ............ Address ~- .14)]'. ~.qji~ . Ce) Real l~staio Company and Agent 'i-eiehhone ................. Cf) Mall the I tAA io the following address: S~ng!e FamHy,-d Multi Falnily ~1 Othai' Number of Bedrooms. _ WATi;. R SUPPL'! h~diviclual We',t lei" ()omrnunity b-] Public Note: If o()mt rit!l~lty well system, fYit.isi have writter~ coflflrrnatior~ fi'om the Stale [)er)al trnont of E~i r¢~ronrnental Conservation attesting to the legality and status Onstte 15 ['ubiic [~1 (;o,~mlunity 17] I-tolcling -[alqk E'] attesting to lhe Iooahty and stat(m Page I of 2 and i~s ~fi ti ~e va id~ i ol dado 51~owll below, t verliy ti ~at my on-giro water sHpply arid, or wastewater disposal oysl.,in oo¢ ~, ~dr,~.,:o,,,,, az!d a(x:,:,.,m . fdes arid from rny iriveslioatlon al~d inspectK)n, tho on..site CAIJTI WELL DATA Well Classification (-' Well Log Present (Y/N) '~ Total Depth t~C~ Cased to Static Water Level ~0' ~,E~z..o~ ~.Iv4E:~ ~o1'-~.~¢_~.. _ Casing Height Above Ground Electrical Wiring in Conduit (Y/N) Separation Distances from Well: To Septic/Holding Tank on Lot MUNICIPALITY OF ANCHORAGE (MOAJ HEALTH AUTHORITY APPROVAL (HAA) CHECI(LIST - FEBRUARY 1984 Legal Description: ~1' I~) ~.- If A, B, C, D.E.C. Approved (Y/N) Date Completed ~'~'~ Yield Depth of Grouting Pump Set At ~¢~ Sanitary Seal on Casing (Y/N) Depression Around Wellhead (Y/N) To Nearest Edge of Absorption Field on Lot _l To Nearest Public Sewer Line Cleanout/Manhole ~ To Nearest Sewer Service Line on Lot Water Sample Collected by ~)~-'f~E-,4 ~-t,-~':~-t~'~=; __ 40~¢~:)~__; Date Water Sample 'rest Results ; On Adjoining Lots ; On Adjoining Lots To Nearest Public Sewer Comments B. SEPTIC/HOLDING TANK DATA Date installed "~"J~C~tt"¢"~:~--Size ~ No. of Compartments Standpipes (Y/N) _ y ~ Air-tight Caps (Y/N). Depression over Tank (Y/N) Pumping/Maintenance Contract on File (Y/N) Holding Tank High-Water Alarm (Y/N) _ Separation Distances from Septic/Holding Tank: / ,~) Foundation Cleanout (Y/N) Y Date Last Pumped ~ ; for Temporary Holding Tank Permit (Y/N) To Water-Supply Well [ To Property Line _-- 1 To Water Main/Service Line Course ~ To Building Foundation To Disposal Field (~ To Stream, Pond, Lake, or Major Drainage Comments Page 1 of 2 72-026(11184) C. ABSORPTION FIELD DATA Soils Rating in Absorption Strata Date Installed '~ ~ ~'~ Width of Field Square Feet of Absorption Area Depression over Field (Y/N) Results of Last Adequacy Test ~ ~/~, Separation Distance from Absorption Field: To Water-Supply Well To Building Foundation Lot To Water Main/Service Line To Stream/Pond/Lake/or Major Drainage Course To Driveway, Parking Area, or Vehicle Storage Area Type of System Design __~:) Length of Field Depth of Field '7, .~ Gravel Bed Thickness Standpipes Present (Y/N) ~ Date of Last Adequacy Test N./A- ),3~..) / To Property Line 't O To Existing or Abandoned System on ; On Adjoining Lots To Cutbank (if present) Comments D. LIFT STATION Date Installed -~--~'b~t...h~, ~ Siz6 in Gallons "Pump On" Level at High Water Alarm Level at Tested for Electrical Codes (Y/N) Dimensions Manhole/Access (Y/N) "Pump Off" Level at Vent (Y/N) Pumping Cycles during Adequacy Test. Meets MOA Comments ** Check Permitted Bedroom Rating Against HAA Request ** I certify that I hav.e check_ed, verified, or conformed to all MOA and HAA guidelines in effect on the date of this inspection. /r/~4~//¢,,~'~'~'-'~' Date- 0¢"~ ~-~ -- -- Signed Company,~,~/'~/vt('/~'-E,~.~W6.~/~. MOA No. 'ST'i~c~'?'~ Receipt No. _?_b Date of Payment Amount: $ ,/A~ Page 2 of 2 72-028 (11/84) .~-. ' Engineer's Seal ~. ¢ ,, E.K. McMIIlan