HomeMy WebLinkAboutRABBIT CREEK VIEW & HEIGHTS BLK 10H LT 11ARabbit Creek View &Heights Block I OH Lot I I A #020-581-37 Municipality of Anchorage Community Development Department Page 1 of 3 On -Site Water and Wastewater Program 4700 Elmore St. • P.O. Box 196650 Anchorage, AK 99519-6650 • http://www.muni.org/onsite • (907) 343-7904 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP121256 PID Number: 020-581-37 ❑ New ❑v Upgrade Name: Jeremy & Dana Cooper ABSORPTION FIELD ❑ Deep Trench ❑✓ Shallow Trench ❑ Bed ❑ Mound Address 8340 Harwood Cir ❑ Other Phone Number of Bedrooms Soil Rating Total depth from original grade 3 0.8GPD/sF 7.5 Ft, LEGAL DESCRIPTION Depth to pipe invert from original grade -*7.5 Ft. Gravel depth beneath pipe 4.0 Ft. Subdivision Block Lot Rabbit Creek View & Heights 10H 11A Fill added above original grade 1.8 Ft, Gravel length 60.0 Ft, Township Range Section Gravel width 5.OFt. Beds: Number of Lines N/A Distance between lines N/A Ft, SEPARATION DISTANCES To Septic Absorption Lift Station Holding Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field Tank Line 600.0 Fly 1 N/AFt. Well 97 (E) 109.6 N/A N/A 100 TANK ❑ Septic ElS.T.E.P. Ll Holding ❑ Other Manufacturer Existing Capacity I 1000G,1. Surface water 100+ 100+ N/A N/A Material Number of compartments Lot Line 11 (E) 1.4 N/A N/A Plastic 2 NA Foundation 5+ (E) 16.1 N/A N/A LIFT STATION Manufacturer Capacity Curtain Drain N/A N/A N/A N/A Gal. RemarksDue to the location of the deck piles, the drain Pump on level at Pump off level at High water alarm at field was moved closer to the property line. I request in. in. in. the drain field to lot waiver be modified to 1'. Pump make and model Electrical Inspections performed by ** See Note 1, Sheet 2. Installer PIPE MATERIAL House to tank Tand a n k to PVC A+ Home Services Drainfield PVC CO/MT PVC Inspector Pannone Engineering Services BENCHMARK (Assumed elevation) 1008 Inspection ��, dates: 10/29/12 2m 10/30/12 Location and description 3" 4' Corner of Deck COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL Engineer's Stamp cit.ONlk F At ��l Conditional Approval: Date . • • .Is l� �r�.. ,d *: 4,97H ... r, ta'tever F 'ahnorae ✓ CE 8149 Approved ' Datea 9?OFESS Inspection Rep _1-1-12.69f NOTE: 1) TOTAL DEPTH IS FROM EXISTING GRADE AT THE TIME OF THIS REPLACEMENT. ORIGINAL GRADE WAS AT APPROXIMATELY 90.3'. LOT UNDEVELOPED LOT UNDEVELOPED NO WELLS OR SEPTICS NO WELLS OR SEPTICS € o� �a HARWOOD CIR REPLACEMENT DRAIN FIELD (P) REMOVED AND REPLACED OLD DRAIN FIELD 60LFx4.0'EDx5'W, 7.5'TD Cz� - -- (TD FROM EXISTING GRADE TODAY)Ld TH-8/13/1979 F - PES TH-1 y \ cn wM1 -. Ow C1 w w _ '� 3BR A Y o 4_ HOUSE j z z y M DCO (E) ; _.. w A _. 3 13 – 109.6'y 1000g SEPTIC TANK (E) �- �--��ggHNB-T6-BE-t6°cfEfldG -� �O 2&M AL. _ I 1 WELL (E) •_ , 0 UTILITY EASEMENT_ EXISTING SEPTIC AREA EXISTING SEPTIC AREA NOTES: PANNONE ENG SVC LLC "��•�� Dote RECORD DRAWING "���..A�q' lk0 11/7/2012 P.O. BOX 100217 ANCHORAGE, AK 99510 f Scale PHONE (907) 272-8218 FAX (907) 272-8211 /Oj•'TH y I•••• I p.LD. NO RABBIT CREEK VIEW & HEIGHTS, BLOCK 10H, LOT 11A \ ? ozo-sal-37 JEREMY &DANA COOPER S'te'venr'R. Pannone j PERMIT No. ' P�: AT.." OSP121256 8340 HARWOOD CIRCLE 1++ NAT.." PLAN ANCHORAGE, AK 99516+ilk\\\` scW— 5h2eOF 3 A B C FC (E) 16.3 T1 (E) 19.7 13.7 DCO 22.1 12.0 C1 33.2 23.6 mi 32.2 21.3 C2 48.0 58.7 MZ 1 49.2 1 58.9 NOTES: PANNONE ENG SVC LLC "��•�� Dote RECORD DRAWING "���..A�q' lk0 11/7/2012 P.O. BOX 100217 ANCHORAGE, AK 99510 f Scale PHONE (907) 272-8218 FAX (907) 272-8211 /Oj•'TH y I•••• I p.LD. NO RABBIT CREEK VIEW & HEIGHTS, BLOCK 10H, LOT 11A \ ? ozo-sal-37 JEREMY &DANA COOPER S'te'venr'R. Pannone j PERMIT No. ' P�: AT.." OSP121256 8340 HARWOOD CIRCLE 1++ NAT.." PLAN ANCHORAGE, AK 99516+ilk\\\` scW— 5h2eOF 3 SPECIAL PROVISIONS TO SPECIFICATIONS 1. ALL CONSTRUCTION WAS INSTALLED AS SPECIFIED IN THE MOST CURRENT EDITION OF THE MUNICIPALITY OF ANCHORAGE STANDARD SPECIFICATIONS (MASS) FOR COMPONENT PARTS AND MATERIALS USED IN CONSTRUCTION OF ON-SITE WASTEWATER DISPOSAL SYSTEMS. 2. ALL WORK WAS IN ACCORDANCE WITH THE ATTACHED SPECIFICATIONS. DIP 3. SCOPE OF WORK: INSTALLED NEW SOIL ABSORPTION SYSTEM. REMOVED EXISTING FIELD. VERIFIED EXISTING SEPTIC FC TANK. T# 4. GROUNDWATER WAS MONITORED AT 8.0 FEET BELOW EXISTING GRADE AS EVIDENCED BY THE SOIL TEST HOLE. AN M# APPARENT WATER TABLE WAS NOT OBSERVED IN ANY OF THE EFFVATIONS LESS THAN 8.0 FEET BELOW EXISTING RIGID INSULATION GRADE. DOUBLE CLEAN OUT DV 4" 0 PERE PIPE FS FLOW SPLITTER OLD DRAIN FIELD 95.1 (FG) 5.0 FILTER FABRIC MOUND (E) BELOW FINISH GRADE OG REMOVE AND REPLACE 93.3 (EG) DRAIN ROCK FG FINISH GRADE FILL (E) 3.0+ EXISTING GRADE AT TIME OF 1979 TEST HOLE _ .E9 8 075— CONSTRUCTION TEST LAB T r TH-1 * _ ,. �- TH 1979 (87.8±) } RETAINING WALL (E) -8T 8 _ _ on 4.0 NOWATER DAYLIGHTING -2.0 ..L{� — AT TOE OF WALL — �85.8� REMOVED OLD SYSTEM — — — EXISTING DRIVEWAY AND BIOMATTED MATERIAL 6.0 LN 7.5 SAND AS REQUIRED GP TO REPLACE BIOMAT -1°,° ffx 9--9.5(78.3) SECTION 77.8 Oo 75.6 j ? ? z�z z Zo mz w INSULATION w mo mo 0 �-w 4" 0 PERF PIPE or �i o z� FILTER FABRIC �a DRAINROCK �¢ v 10008 _ _. ... SEPTIC 92.8 TANK(E) 12 PROFILE SEE SECTION & PARAMETERS DESIGN PARAMETERS REPLACEMENT SEPTIC SYSTEM NO. BEDROOM: 3 (450 gpd) TANK SIZE: 1000g (E) PERC RATE = 1.3 MPI SOIL RATING: 0.8 GPD/SF AREA ROD: 562.5 SF SYS, TYPE: WIDE TRENCH 4.0' E.D RF: 0.50 MIN LENGTH: 56.25 LF LEGEND W WATER LINE/ WELL RADIUS — SS — NEW SEPTIC USE: 60 LF X 5' WIDE, 4.0' E.D., 7.5' TO (TO FROM EXISTING GRADE TODAY) TOTAL AREA: 600.0 SF ABBREVIATIONS CU COPPER DIP DUCTILE IRON PIPE TH TEST HOLE FC FOUNDATION CLEAN OUT T# TANK CLEAN OUT NO. C# CLEAN OUT NO. M# MONITOR TUBE NO. R. I. RIGID INSULATION DCO DOUBLE CLEAN OUT DV DIVERTER VALVE FS FLOW SPLITTER BFG BELOW FINISH GRADE OG ORIGINAL GRADE FG FINISH GRADE NOTES: RECORD DRAWING PANNONE ENG SVC, LLC OF Ak y P.O. BOX 1OD217 ANCHORAGE, AK 99510 r '�� ""' q5' l� PHONE (907) 272-8218 FAX (907) 272-8211 ;of *�4' TMFy.*I ...... � . RABBIT CREEK VIEW &HEIGHTS, BLOCK 10H, LOT 11A �• S. JEREMY &DANA COOPER �) Steven • R. •R GnnoreU`�. P. CE 81 a9 8340 HARWOOD CIRCLE �1 `mss DESIGN DETAILS ANCHORAGE, AK 99516 ��►afD� m�,�a Date 11/7/2012 Scale NTS P.I.D. NO 020-581-37 'ERMIT NO 3 OF 3 TEST HOLE 1 SOILS LOG - PERCOLATION TEST SLOPE 21TE Pi &N DATE PERFORMED: 7/26/12 READING OR NET TIME WATERTIME LEVEL READING HARWOOD CIR 1 07/26/12 3:24 --- 4.65 -- 2 3 6.5MIN 10.50(DRY) 5.85 3 3:31 --- 4.65 -- '- 4 7.25 MIN 10.50 (DRY) 5.85 -- 5 --- 4.65 -- w 6 GM SILTY GRAVEL X p I F- TH w 7._ - TH-8/13/1979. PES TH—1 N II 8 s 7 3BR Y HOUSE c) 10 8/3/2012 A / \E) Z BOH 12 13 WAS GROUND WATER SLOPE 14 ENCOUNTERED? N 15 IF YES, AT WHAT TH 16 DEPTH? -DRY-' X 17 DEPTH TO WATER AFTER MONITORING? -9.5'- 13 DATE: 8/3/2012 DATE PERFORMED: 7/26/12 READING DATE CLOCK NET TIME WATERTIME LEVEL READING NETDROP 1 07/26/12 3:24 --- 4.65 -- 2 3:30:30 6.5MIN 10.50(DRY) 5.85 3 3:31 --- 4.65 -- 4 3:38:15 7.25 MIN 10.50 (DRY) 5.85 5 3:39 --- 4.65 -- 6 3:46:45 7.75MIN 10.50(DRY) 5.85 PEROLATION RATE 1.3 (min/inch) PERC HOLE DIAMETER 6 inches TEST RUN BETWEEN 3 FTAND 4 FT COMMENTS: Test hole excavated by A+ HOME SERVICES. Prec hole was presoaked Test run for one hour. Last 3 readings reported PERFORMED BY: Steven R. Pannone, P.E. I CERTIFY THAT THIS TEST WAS PERFOI WITH ALL STATE AND MUNICIPAL GUIDLINES IN EFFECT ON THE DATE OF THIS' D IN ACCORDANCE NOTES: PAMONE ENG SVC, LLC. P.O. BOX 102954 ANCHORAGE, AK 99510 PHONE (907) 272-8218 FAX (907) 272-8211co ~ � OF k �••. Lgsll) i ~ Py+� *; 49 TH • * // '.. :.. / ••Steven �'an •.• / /PERMIT / -V.•. CE 8149 \� '�l���o�ssioNa`-� Date g�27�2012 FOR CONSTRUCTION Scale NTS 020-581-037 No. OSPI21256 RABBIT CREEK VIEW & HEIGHTS, BLOCK 10H, LOT 11A JEREMY & DANA COOPER 8340 HARWOOD CIRCLE ANCHORAGE, AK 99516 SOILS LOG Sheet 3 OF 3 Pannone Engineering Services uc Steven R. Pannone, Principal Registered Professional Engineer E-mail: steve@panenRak.com September 13, 2012 Municipality of Anchorage Development Services Department On -Site Water & Wastewater Program 4700 S. Bragaw Street P. O. Box 196650 Anchorage, Alaska 99519 Subject: Rabbit Creek View & Heights Block 10H, Lot 11A Field Orientation Waiver Request Ladies and Gentlemen: I am requesting a waiver for the minimum distance to a break in the terrain where the slope is greater than 25 percent. There is a retaining wall approximately 18' away where the top of system is at approximately the same elevation as the top of wall and the bottom of the system is at approximately the same elevation as the toe of the wall. This system operated for over 30 years in this configuration without any effluent daylighting, and has been operating in failure for the past 2 to 3 years without any effluent daylighting. Granting this waiver is not likely to affect the health and safety of this lot or the surrounding lots now or in the future. If you have any questions or concerns, please contact me at 272-8218. Sincerely, Steven R. Pannone, P.E. Owner/Civil Engineer Mailing: P.J. Box 100217, Anchorage, Iii{ 99510-0217 Physical: 332 East Manor, Anchorage, AK 99501 Telephaie: (907) 272-8218 FAX: (917) 272-3211. Municipality of Anchorage P.O. Box 196650 0 4700 Elmore Road Anchorage Alaska 99519-6650 0 (907) 343-7904 0 Fax (907) 343-7997 http://www.muni.org/Onsite Development Services Division On -Site Water and Wastewater Program mellr S Department **** VARIANCE/WAIVER REVIEW **** Waiver#: OSP121258 COSA#: Permit#:OSP121256 PID#: 020-581-37 Legal Description: Rabbit Creek View and Heights Block 10H Lot 11A Engineer: PES Applicant: Dana and Jeremy Cooper Your request for a waiver of the required 10 feet horizontal separation from the absorption field to the property line has been approved. The approved separation distance is 5.5 feet. In addition, the field is approved to be 18' away from a retaining wall. See the waiver request letter for mitigating factors. Re, t</ y z - v/ r"c eg Y- pry, e n g I;% e e v r e q d T�r- P 6-//-113 This waiver approval applies to the proposed absorption field only. Any future upgrade to the on-site wastewater disposal system will require all separation distances be met or another approval from this department. ® The affected adjacent property owner(s) have been given a 7 day notice regarding this waiver. ❑ Notarized letter(s) of nonobjection have been received from the owner(s) of the affected adjacent property. ❑ Adjacent properties are not affected by this waiver. ............................................................................... Waiver is Granted: X Waiver is not Granted: Date: Approved by:Lh/G"�� Name of Revieyv r ......................................................... .................... Rec#: 05936G Amount: $200.00 Date Paid: 8116112 **** VARIANCE/WAIVER REVIEW **** On -Site Wastewater Disposal System Permit MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water & Wastewater Program 4700 Elmore Road, PO Bax 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Permit Number: OSP121256 Tax Code Number: 02058137000 Work Type: Septic Upgrade Permit Effective Dates: September 14, 2012 to September 14, 2013 Design Engineer: PANNONE ENGINEERING SERVICE Subdivision: RABBIT CREEK VIEW & HEIGHTS Site Legal Address: RABBIT CREEK VIEW & HEIGHTS BILK 10H LT 11A G:3341 Owner/Address: COOPER DANA S & JEREMY A 8340 HARWOOD CIRCLE ANCHORAGE AK 995165566 Site Mailing Address: 8340 HARWOOD CIR, Anchorage This permit is for the construction of: Y Disposal Field N Septic Tank N Holding Tank N Privy All construction must be in accordance with: Lot Size in Sq Ft: 23405 Total Bedrooms: 3 N Private Well N Water Storage 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Special Provisions: An Onsite employee is to be onsite at the start of construction to confirm conditions. Received Issued By: tL_i r T��� Date: ��Z Municipality of Anchorage Development Services Division On -Site Water and Wastewater Program tzsent S, ^ D�parTment **** VARIANCE/WAIVER REVIEW **** Waiver#: OSP121258 COSA#: Permit#:OSP121256 PID#: 020-581-37 Legal Description: Rabbit Creek View and Heights Block 10H Lot 11A Engineer: PES Applicant: Dana and Jeremy Cooper Your request for a waiver of the required 10 feet horizontal separation from the absorption field to the property line has been approved. The approved separation distance is 5.5 feet. In addition, the field is approved to be 18' away from a retaining wall. See the waiver request letter for mitigating factors.. This waiver approval applies to the proposed absorption field only. Any future upgrade to the on-site wastewater disposal system will require all separation distances be met or another approval from this department. ® The affected adjacent property owner(s) have been given a 7 day notice regarding this M"PAI &DA ❑ Notarized letter(s) of nonobjection have been received from the owner(s) of the affected adjacent property. ❑ Adjacent properties are not affected by this waiver. ........................ ...6000 ........... ....................... Noun .......... Waiver is Granted: X Waiver is not Granted: Date: XZ Approved by: �� Name of Revieyv r ............. SON ................... ANN ................. .. ...................a Rec#: 05936G Amount: $200.00 Date Paid: 8116112 **** VARIANCEIWAIVER REVIEW **** MUNICIPALITY OF Community Development Department Development Services Division On -Site Water & Wastewater Program Mayor Dari Sullivan Phone: 907-343-7904 Fax: 907-343-7997 ON-SITE SEWER/WELL PERMIT APPLICATION 5�� FOR A SINGLE FAMILY DWELLING Parcel I.D. OZO Property owner(s) cy.ery )n -3F'CJ6i°9 � Lcy?'Pegne Day phone Mailing address q'3o 0.0,eii5 o c-19 Std• �� � y �� Site address !!� 3 yc7 Ns�tva cid Legal description (Sub'd., Block & Lot) PNt��;rctf r�r JISJ if yr�l B. Ip 4e—, I& Legal description (Township, Range & Section) Lot Size Z3 qvigSq. Ft. Number of Bedrooms 3 THIS APPLICATION IS FOR: THIS APPLICATION IS AN: (® all that apply) Initial E]Absorption Field rrQ Septic Tank F1 Upgrade K Holding Tank ❑ Renewal ❑ Privy ❑ Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: Xu • 0 Date of Payment: nn g 16112 Receipt Number:h Permit No. 05P Waiver Fees: Date of Payment: lb�iq Receipt Number: Waiver No. GABui1ding%0n Site%Forms\Client FormsTermit App_010411,doc (Rev. 1A 1) Pannone Engineering Services uc Steven R. Pannone, Principal Registered Professional Engineer E-mail: steve(annaneneak.com August 14, 2012 Municipality of Anchorage Development Services Department On -Site Water & Wastewater Program 4700 S. Bragaw Street P. O. Box 196650 Anchorage, Alaska 99519 Subject: Rabbit Creek View and Heights, Block 10H, Lot 11A Septic System Permit Upgrade Request Ladies and Gentlemen: I am writing to request a permit to construct an upgrade system be issued for this property. The proposed systems will serve an existing three (3) bedroom house. Currently the lot is developed. The existing drain field is in failure and will be abandoned by removal. The existing system was installed in this location in 1979 and operated for over 30 years in that location, it is now in failure and no daylighting of effluent to the surface has occurred. Due to space available the new drain field will be built in the same location; any part of the existing field within 10' of the new drain field will be removed. The lot is served by a private well that is located over 100' from the new system. The surrounding lots are also served private wells that are located over 100' from the new system. 1. Soils. One test hole was excavated by Pannone Engineering Services in July, 2012, and the ground water was monitored for seven days. Ground water was monitored at a depth of 9.5' below grade. Bedrock was encountered and 10.0' below grade. It is my opinion, based on the results of the percolation tests and overall soils appearance; an application rate of 0.8 gallons/day/square feet should be used for a conventional wastewater system. 2. Soil Absorption System Design. a. See Sheet 2 of the design package 3. Surface Water: There is no surface water within 100 feet of the proposed septic tank and drain field. The proposed drain field upgrade will maintain at least 100 feet from all surface water and drainage ditches. 4. Topography: The drain field will be installed in the existing mound in the same location as the existing field. The ground slopes to the left and the right from the center of this mound. Mailing: P.O. Box 100217, Anchorage, AK 99510-0217 Physical: 332 East Manor, Anchorage, AK 99501. Telephone: (907) 272-8218 FAX. (907) 272-5211. Page 2 of 2 5. Lot Line Waiver: I request a lot line waiver from the drain field to the west property line due to the small area available for the construction of the field. 6. Drawing Markings: The Drawings are marked "For MoA Review Only". When written notification that the review is complete and that there are no further comments is received from MoA On -Site Department, the note will be removed and "Issued for Construction" drawings will be issued. The proposed installation will not affect the future development of the surrounding or existing lots. There are no wells or septic systems within 100 feet of the proposed septic location. If you have any questions or concerns, please contact me at 272-8218. Sincerely, Steven R. Pannone, P.E. Owner/Civil Engineer Attachments -Soils Log -Septic System Design Mailing: P.O. Box 100217, Anchorage, AK 99510-0217 Physeal: 332 East [Aanor Ave, Anchorage, Aim 99503, Telephone: (907) 272-8218 FAX: (907) 272-8211 Pannone Engineering Services LLC Steven R. Pannone, Principal Registered Professional Engineer E-mail: steve(f panengak.com September 13, 2012 Municipality of Anchorage Development Services Department On -Site Water & Wastewater Program 4700 S. Bragaw Street P. O. Box 196650 Anchorage, Alaska 99519 Subject: Rabbit Creek View & Heights Block 10H, Lot 11A Field Orientation Waiver Request Ladies and Gentlemen: I am requesting a waiver for the minimum distance to a break in the terrain where the slope is greater than 25 percent. There is a retaining wall approximately 18' away where the top of system is at approximately the same elevation as the top of wall and the bottom of the system is at approximately the same elevation as the toe of the wall. This system operated for over 30 years in this configuration without any effluent daylighting, and has been operating in failure for the past 2 to 3 years without any effluent daylighting. Granting this waiver is not likely to affect the health and safety of this lot or the surrounding lots now or in the future. If you have any questions or concerns, please contact me at 272-8218. Sincerely, Steven R. Pannone, P.E. Owner/Civil Engineer Mailing: P.Q. Box 100227, Anchorage, AK 99510-0227 Physical: 332 Frit Manor, Anchwrat;c, AK 99501 Telephone: (907) 272-5218 FAX: (907) 272-5211. LOT UNDEVELOPED LOT UNDEVELOPED NO WELLS OR SEPTICS NO WELLS OR SEPTICS o� HARWOOD CIR REPLACEMENT DRAIN FIELD (P) REMOVE AND REPLACE OLD DRAIN FIELD 60LFx4.0'EDx5'W, 7.5'TD (TO FROM EXISTING GRADE TODAY) w ' I TH-8/13/1979�I Of v _ c) -- PES T oW z w_ 3BR Y ' z o 5.9-1 HOUSE o z I o 13 0�2 / 109.0 1000g SEPTIC TANK (E) REPLACE OUTSIDE WELL RADIUS IF FOUND TO BE LEAKING " ---_ ZF _ _ I WELL (E) il. 1-0 UTILITY EASEMENT \�� EXISTING SEPTIC AREA C�� w ,n,� w EXISTING SEPTIC AREA NOTES: �7�77�7 N EN Ip,p gpXOj 010217 ANCHORAGE, CK 995L10C PHONE (907) 272-8218 FAX (907) 272-8211 .����Date (��F A�q\cSk1� /rGj�P j*:49nI �... .. .. ...... Steven . Gn me' � '•. CE 8149 .',c`rj I c .. ion"* 9/13/2012 FOR CONSTRUCTION Scale 1'-50' RABBIT CREEK VIEW & HEIGHTS, BLOCK 10H, LOT 11A JEREMY & DANA COOPER 8340 HARWOOD CIRCLE ANCHORAGE, AK 99516 P.I.D. NO 020-581-37 PERMIT NO. OSP121256 PLAN Sheet �i A?OFESSOkN 1 OF 3 SPECIAL PROVISIONS TO SPECIFICATIONS 1. ALL CONSTRUCTION SHALL BE INSTALLED AS SPECIFIED IN THE MOST CURRENT EDITION OF THE MUNICIPALITY OF ANCHORAGE STANDARD SPECIFICATIONS (MASS) FOR COMPONENT PARTS AND MATERIALS USED IN CONSTRUCTION OF ON-SITE WASTEWATER DISPOSAL SYSTEMS. 2. ALL WORK SHALL BE IN ACCORDANCE WITH THE ATTACHED SPECIFICATIONS. 3. SCOPE OF WORK: INSTALL NEW SOIL ABSORPTION SYSTEM, REMOVE EXISTING FIELD. VERIFY EXISTING SEPTIC TANK. 4. GROUNDWATER WAS MONITORED AT 8.0 FEET BELOW EXISTING GRADE AS EVIDENCED BY THE SOIL TEST HOLE. IF AN APPARENT WATER TABLE IS OBSERVED IN ANY OF THE EXCAVATIONS LESS THAN 8.0 FEET BELOW EXISTING GRADE NOTIFY THE ENGINEER IMMEDIATELY. '90.8 aR —2.0 GM 4' 0 PERF PIPE OLD DRAIN FIELD 5.0 FILTER FABRIC MOUND (E) REMOVE AND REPLACE —97.1 DRAIN ROCK FILL (E) 3.0+ EXISTING GRADE .92.8 .. ..,. ,.. —0-.5 AT TIME OF 1979 TEST HOLE CONSTRUCTION TEST LAB —10.0— z <o z z 1000g SEPTIC TANK (E) REMOVE OLD SYSTEM AND BIOMATTED MATERIAL SECTION 5 wo mz o J 5 00 nn a Q TH 1979 T'r 0 PERF PIPE FILTER FABRIC DRAIN ROCK PAINING WALL (E) WATER DAYLIGHTING TOE OF WALL PROFILE SEE SECTION & PARAMETERS LEGEND ABBREVIATIONS DESIGN PARAMETERS CU COPPER REPLACEMENT SEPTIC SYSTEM W WATERLINE/ DIP DUCTILE IRON PIPE NO. BEDROOM: 3 (450 gpd) WELL RADIUS TH TEST HOLE TANK SIZE: 10009 (E) FC FOUNDATION CLEAN OUT PERC RATE = 1.3 MPI SS NEW SEPTIC T# TANK CLEAN OUT NO. SOIL RATING: 0.8 GPD/SF C# CLEAN OUT NO. AREA ROD: 562.5 SF M# MONITOR TUBE NO. SYS. TYPE: WIDE TRENCH 4.0' E.D. R.I. RIGID INSULATION RF: 0.50 MIN LENGTH: 56.25 LF DCO DOUBLE CLEAN OUT DV DIVERTER VALVE USE: FS FLOW SPLITTER 60 LF X 5' WIDE, 4.0' E. D., BFG BELOW FINISH GRADE 7.5' TD (TD FROM EXISTING GRADE TODAY) OG ORIGINAL GRADE TOTAL AREA: 600.0 SF FG FINISH GRADE NOTES: _����Date PANNOO7GRAGE,CK 995LioC �eaFA�\qsl�) 9/13/2012 FOR CONSTRUCTION PHONE (907) 272-8218 FAX (907) 272-8211*�. 49 TH Scale� NTS "" '•'• P.I.D. NO RABBIT CREEK VIEW & HEIGHTS, BLOCK 10H, LOT 11A / / 020-581-37 JEREMY & DANA COOPER e MIT No. P(r.•. CE 8149 % OSP121256 8340 HARWOOD CIRCLE DESIGN DETAILS ANCHORAGE, AK 99516 'Ilk �FROFESSON� See pOF 3 \\ ��� 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 TEST HOLE m GM ISILTY GRAVEL BOH 8/3/2012 DATE PERFORMED: 7/26/12 SOILS LOG - PERCOLATION TEST SLOPE X TH HARWOOD CIR I i WAS GROUNDWATER ENCOUNTERED? N IF YES, AT WHAT DEPTH? -DRY-' DEPTH TO WATER AFTER MONITORING? -9.5'- DATE: 8/3/2012 SLOPE READING CLOCK DATE TIME NET TIME WATER LEVEL READING NET DROP 1 07/26/12 3:24 --- 4.65 -- 2 3:30:30 6.5MIN 10.60(DRY) 5.85 3 3:31 --- 4.65 -- 4 3:38:15 7.25 MIN 10.50 (DRY) 5.85 5 3:39 --- 4.65 -- 6 3:46:45 7.75 MIN 10.50 (DRY) 5.85 PEROLATION RATE _ 1.3 (min/inch) PERC HOLE DIAMETER 6 inches TEST RUN BETWEEN 3 FT AND 4 FT COMMENTS: Test hole excavated by A+ HOME SERVICES. Prec hole was presoaked. Test run for one hour. Last 3 readings reported PERFORMED BY: Steven R. Pannone, P.E. I CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDLINES IN EFFECT ON THE DATE OF THIS TEST. "°TES:PANNONE ENG SVC LLC P.O. BOX 102954 ANCHORAGE, AK 99510 PHONE (907) 272-8218 FAX (907) 272-8211 —`'OF A ��\ i '��••••• `:9S,1� Steven• �•PGn ••(•• / r�) mss, CE 5149ir l`\\\OFES Date e/27/2otz FOR CONSTRUCTION Scale Scale NTS RABBIT CREEK VIEW & HEIGHTS, BLOCK 1OH, LOT 11A JEREMY &DANA COOPER 8340 HARWOOD CIRCLE ANCHORAGE, AK 99516 P.I.D.0-581- 7 PERMIT No. OSP121256 SOILS LOG Sheet 3 OF 3 MUNICIPALITY OF ANCHORAGE / ® DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION ENVIRONMENTAL ENGINEERING DIVISION 825 L Street - Anchorage, Alaska 99501 Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT i NAME (' EW �����-t}1..,..� / I 7'i moi, 1 °''fi ,_ ❑ UPGRADE f DY),) c _ MAILINGADDRES ry y LEGAL DESCIPT� � � � � j (VQ } � LOCATION � NO. OF BEDRj1gMS Uy az Well Absorption areaDwelling DISTANCE TO: Manufacturer Mate a� PERMIT NO c -t: 4 No, of compartmentslaaj.may M to Liq. cp�ci y� gallons Inside length j� bb IF HOMEMADE: v� Width - -PER�� Liquid depth _ e O Z d DISTANC Dwelling Man ctu rer Material Liquid capacity in gallons u x�w L1 -a � w DISTANCE TO: Well o /) ll:J _ Foundation rE � t Nearest lot line /.� (� PERMIT?ai �� a Z Z w �Zw No. of lines 1 l�, Length of ea h I'n t _f E Total length o li f Trench w inches Distance ben fines p Top of tile to finish grade Material benea t tile Total effective abrfTJ)n rea inches Length Widt ' Depth PER w h W [6 Type of crib,-- - Crib diameter rib depth Total effective absorptio � rea w N DISTANCETO: Well Buildin undation Nearest _ _- r a Class Depth �I i" t Driller Q `� i Distance to lot Ijne , C t PERMIT Nn 7 W _ DISTANCE TO: Buildingfoundat�y7� oV-! Sewer line Septic tank Absorption area(sl .L OTHER G PIPEMATERIALS _ SOIL TEST RATING �6o INSTALLER REMARKSI,,— ''1 e A (Yl 0 a Yd - _ - eA do �0 vJA--re-0. 1 Q!_0 APPLO DATE EG L Ck- I 72-013 (Rev. 3178) ��x~-.�.�~ x`o�o�x��r n��nw e� rox���� ���k!_!� DEPHRTMENT O' HEHLTH HND E0V0RONMENT8L P. /TEIE: TlOI'll 825 /L' STREET/ ONCHOROGE. HK99501 264�4720 /' � 1 4; f W�q ��.-- --/ 14 11 ��� P-0 'Y' ������ ������ ' ~~� HPPLICHNT T. Fl. SCOTSO. STHTION :344 2972 LOCHTION LEGHL L -A. -J. Bi0 RHB8IT CRK HTS LOT SIZE 2]400 SQUHRE FEET TYPE OF SOlL RBSORRTTON SYSTEM IS: TRENCH MHXlMUM NUMBER OF BEDROOMSRHTING (SQ FT/BR)� 150 [HE REQUlRFD SlZE OF THE SUIL H8SORPTlUN SYSTEM lS� V�­o ����� � ������������ ��� ���F��L_ ����I�= � THE LENGTH DIMENSION IS THE LENGTH (lN FEET) OF THE TRENCH OR DRHINFlELD THE DEPTH OF H TRENCH OR PIT IS THE DlSTRNCE BETWEEN THE SURFRCE OF THE GRQUND RND THE BOTTOM OF THE EXCRVOTlON (lN FEET) THERE IS N0 SET WIDTH FOR TRENCHES. THE GRHVEL DEPTH IS THE MINIMUM DEPTH OF BETWEEN THE OUTFHLL PIPE RND THE BOTTUM OF THE RYHTION (IN FEET) �L'�- 11G� ILLY J'� F'.:i" F_1��­ ��- V 1: 071 W 10 P41 K :10 17 ;?f IJEE— A. ���������11�-!f �; PERMlT HPPLICHNT HHS THE RESPONSIBILITY TO INFORM 11-1I5 DEPHRTMENT DURING THE INSTHLLHTION lNSPECTIONS OF ANY WELLS RDJHCENT TO THlS PROPERTY HND THE NUMBER OF RESIDEN(VES THHT THE WELL WILL SERVE. 0 - I �0CIO < Is! Do 1 1KJ 40 Kos K Q -1 - I KI) N to HOT TZI IRE -t: �� BHCKFILLING OF RNY SYSTEM WITHOUT FINAL INSPECTION 1-11,10 HPPROvHL BY THIS DEPHRTMENT WILL BE SURJECT TO PROSECUTlON 1 -V SAW" X �(0 E57 IS Q FSE 14 7 It at.' :1. As 7" SH I CERTIFY THOT 1� I HM FHMlLIHR WlTH THE REQUlREMENTS FOR ONITE SEWERS HND WELLS HS SET FORTH BY THE MUNICIPHLITY OF HNCHORHGE 2l WILL INSTALL THE SYSTEM IN HCCORDHNCE WITH CODES ]� I UNDERSTRND THRT THE ON~SITE SEWER SYSTEM M8Y REQUlFIE ENLHRGEMENT IF T RESlDENCE lS REMODELED TO INCLUDE MORE THHN ] BEDROOMS CONSTRUCTION TEST LAB "One Test is worth a Thousand Opinions" 2204 Cleveland Anchorage, Alaska 99503 277-0231 Performed for Tom Scott Legal Description: This For --n reports: Lot 11 SOILS TEST Block 10 yes Depth Soil Characteristics Feet _ Brown Silty Sandy Gravel (GP) { 1 12' Bottom of Was Ground water En If YES, what depth? Date Performed Subdivision Rabbitt Creek Height PERCOLATION TEST a Reading i Date Time Net Time Depth to H2O Net Drainage Mr lluA a� •. M�UMNN_ MEN vMIJMM IN C=::C 'C MM IN Lei IN MW Reading i Date Time Net Time Depth to H2O Net Drainage Mr lluA a� •. M�UMNN_ MEN vMIJMM IN C=::C 'C Reading i Date Time Net Time Depth to H2O Net Drainage 1rr(o) I � Percolation Propos Depth CO')r4ENTS : llation Minute SEEPAGE PIT DRAIN FIELD Depth to Bottom of Pit or Trench_ feet drainage area required per bedroom. Test Perfo med y D. Paul JuData Certified Bv: Construction •resL Lau Date 8/13/79 WATER WELL LOG FOSS DRILLING 1336 Ingra Street Anchorage, Alaska 99501 WELL OWNEf Uj/ ,jo �yUS�Eg 0F WELLS, LOCATION Lint I) J�)f3/i,K 1%� I i�I-��i'_.L f'�e,✓��� /'7F.i>r,� � SIZE OF CASING DEPTH OF HOLELIA_FT. CASED TO FT. � STATIC WATER LEVEL.,�)/ FT. YIELD b GAL.PER.MIN. WITH .e_ FEET OF DRAWDOWN. REMARKS DATE COMPLETED9 PUMP TO RE SET AT Los Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Program s" 4700 Elmore Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907)343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL FOR A SINGLE FAMILY DWELLING CC Parcel l.D. COSA # dD &:*�5 3 r , ,•= - Expiration Date: 1. GENERAL INFORMATION Complete legal description _Ribktk Creolt He;jkfs DIY, lo►! LT UAL .,Location (site address) 8340 HarWuoal C%rc.,*- Current Property owner(s) Ct r;s Ms4oi .� Day phone 93o-40-31 Mailing address + 8340 Na ,,00h L; ke.t Anc�i AK 99S16 Lending agency Day phone Mailing address Real Estate Agent Day phone Mailing Address Unless otherwise requested, COSA will be held by DSD for pickup. 2. NUMBER OF BEDROOMS: 3 3. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well ® Individual On-site Individual Water Storage ❑ Individual Holding Tank ❑ Community Class Well ❑ Community On-site ❑ Public Water System ❑ Public Sewer ❑ The Municipality of Anchorage Development Services Department (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of On -Site Systems Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues COSAs upon request to homeowners. Certificates of On -Site Systems Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water sample results. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm .Souc•rtlsIAtt-elNrr Phone 7_35.3116 Address 203 W. It Fr A�� SH... i-oT..Alk 115b Engineer's Printed Name 5. DSD SIGNATURE Approved for bedrooms. Disapproved. Date 1013r10R `'4gnaTl� ?v I LABS E. ..FUAY.Liv�D'�, f' \ 10,`10 $ . •`!�i Conditional approval for bedrooms, with the following stipulations: Attachments: COSA Checklist X Septic System Advisory Well Flow Advisory Nitrate Advisory ., (Roy 11N5) Arsenic Advisory Maintenance Agreements Supplemental Engineer's Report Other Original Certificate Date: m f Z O Municipality of Anchorage Development Services Department / Building Safety Division -- On -Site Water & Wastewater Program 4700 Elmore Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907)343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST Legal Description: Vg%1',E ti -QV "e_;1Qs 91K to Lo} II Parcel ID: A. WELL DATA Well type L4 -At If A. B, or C provide PWSID # = Well Log (YIN) Date completed H /7 N Sanitary seal (Y/N) Y Total depth I I a ft. Cased to aD i ft. FROM WELL LOG Date of test Static water level 99 ft. Well production (D g.p.m. WATER SAMPLE RESULTS: Coliform _ colonies/100 mL Nitrate l6l mg/L Arsenic: ND ug/L date of sample: 23 06 B. SEPTIC/HOLDING TANK DATA 1 Tank Type/Material v Pl"A, Tank size 1000 gal. Number of Compartments Z Y Wires properly protected (Y/N) Y Casing height (above ground) )A+- in. AT INSPECTION xc og 53 ft. 4.0 g.p.m. Other bacteria _ 0 colonies/100 mL Collected by: f _Aes J° u Date installed 9 .1201114q Cleanouts(Y/N) y Foundation cleanout (Y/N) Depression over tank (Y/N) N High water alarm (YIN) y✓ Date of pumping 9 2°Og Pumper NortklcQ Pu. 6A, Set v�ce- C. ABSORPTION FIELD DATA I Date installed '1 20 k9 SoiIiating (g.p.d./ft2 or(/bdr ) ISO System type OcaQ Tench Length ft. Width aro ft. Gravel below pipe ft. Total depth ft. EH. absorption area 552ft= Monitoring tube Y Depression over field 4/ Date of adequacy test 916 oa Results (Pass/Fail) 11,455 For .3 bedrooms 4t . S.^? Fluid depth in absorption field before test 42 in. 11 i�" Water added gal. New depth 51 -Min. 3Z;A. v 54«e ;hs,�,p Elapsed Time: 155 min. Final Fluid depth 55 in. 25 �• Absorption rate >= 450 g.p.d. Any rejuvenation treatment (past 12 mo.) (YIN & type) A/eAt RI-o%jn If yes, give date S..Mv r641.s }o bt' set COSA 'Iip -zt ay $ �k-Tcmtf", Mi jnS1�11E6. �CAS4rQM�n� aiPf1� i. Hyo cv��t� ion _rn et m -r. D. LIFT STATION Date installed Size in gallons Manhole/Access (Y/N) 'Pump on' level _ in. 'Pump off" level at in. High water alarm level in. Datu Cycles to Meets alar & uit requirements? E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tankllift station on lot q-+' ('See wg;~L) On adjacent lots 100 '+ Absorption field on lot loo + Public sewer main N/A Sewer /septic service line 25 +- Animal containment areas So 1 t On adjacent tots Ioo'f Public sewer manholelcleanout N!A Holding tank N/- Manurelanimal excrete storage areas I/IA SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 5 r Property line 5 I+ Absorption field 5 t Water main 10,+ Wells on adjacent lots too %+ 1 Water service line 10 + Surface water N. O• SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line _ 51e u4iu 0 Building foundation 10'+ Water main 101+ I Water Service line 10 + Surface water At -0, Driveway, parking/vehicle storage i Curtain drain N,O. Wells on adjacent lots I0Dt F. COMMENTS G. ENGINEER'S CERTIFICATION 't� QF Al, i C I certify that I have determined through field inspections and ; 49TH review of Municipal records that the above systems are in % conformance with MOA COSA guidelines in effect on this date. � i3 ffU Engineer's Printed Name Date Io13lobItOE551G l Fo COSA Fee $ 4� Date of Payment Receipt Number &4 (Rev. 11/05) Waiver Fee $ Date of Payment Receipt Number tot vJ i I m 1� V N r � � .k J SCS Rena 1085227001 Client Name Tobbcn Spurkland P.G. Project Name/9 834011arwood Cir Client Sample ID 83401larwood Cir Matrix Drinking Wates PWSID 0 Printed Date/rine 10/022008 15:31 Collected Daternme 09:232008 12:10 Rmlved Date/Time 09242008 8:57 Technical Director Stephen C. Ede Samplc Remarks: Allowable Prep Analysis Parameter Results PQL Units Method Container ID Limits Date Date Init Metals by ICP/MS ug/l. Arsenic C Waters Department 09/30/08 10;01/08 NRB Total Nitrate/Nitrite-N Hierobioloav Laboratory Colony Count Total Coliform Fecal Coliform ND 5.00 ug/l. EP200.8 C (<10) 09/30/08 10;01/08 NRB 1.67 0.100 mp/L Sh120 450ONO3-F B (<10) 09/25/08 JDZ 0 coi'100mL SN1209222B A (Q00) 09/24'08 DLC 0 col/100mL SM209222D A (<I) 09.24.08 DLC 0 col/100ml- SM209222B A (<I) 09/24/08 DLC Parcel I.D. rt oA�r �- Cow�„i Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907)343-7904 CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING 020-113-36 1. GENERAL INFORMATION HAA# OH — 0 3011 Expiration Date: !�&.sj !— Complete legal description ter 11- Rlnrk 1n; Rehbit Creek Heights Subdivision Location (site address or directions) :Cann Harcnnd rir Anchorage, AK Current Property owner(s) Mark Dunne Day phone 786-7310 Mailing address Lending agency Mailing address Real Estate Agent Mailing Address c/o Bond, Stephens, b Johnson 3000 'A' St. Ste. 200 Unless otherwise requested, HAA will be held by DSD for pickup. Day phone Day phone 2. NUMBER OF BEDROOMS: 3 3. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well [XXjC Individual On-site ' B Individual Water Storage ❑ Individual Holding tank ❑ Community Class Well ❑ Community On-site ❑ Public Water System ❑ Public Sewer ❑ The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of Health Authority Approval (HAA) based only upon the representations given In paragraph 4 by an independent professional civil engineer registered In the State of Alaska. Certificates of Health Authority Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal andlor water supply system. DSD also issues HAAs upon request to homeowners. Certificates of Health Authority Approval are valid for 90 days from the date of Issue for properties served by a private or Class C well and may be reissued with new water sample results. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. � 01-20-05 02:19PM FROM-CTiE ESI, SCS ENV SERVICES SGS Aef.N 1050286001 Client Name S do S Engineering Project Name/N Lt 11, Bilk 10 Rabbit Crk Client Sample ED LI 1, 810 Rabbit Crk Heights SD Matrix Drinking Water 9075615301 T-654 P.02/06 F-093 All Dates/1'lmes are Alaska Standard Time PrintedDate/Cime 01/20/2005 13:18 Collected Date/time 01/142005 13:00 Received Date/time 01/142005 13:55000 Technicalirrc or tephen��'�f+'w� Aeleas Sample Remark+: AOse awable Prep Analylait Pvenetcr Results PQL units ktedw Conuiner ID Limn Dote Dale Haters Department Nitrate -N 1.52 0.100 mg/L EPA300.0 B (<=10) 01/15/05 XM Microbiology Laboratory Tutal Coliform ] OD, No Coli col/100mL SM20 9222D A (<-1) 01/14/05 DKC Municipality of Anchorage o�'Po�' „fie Get Development Services Department s Building Safety Division On -Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. 0 a O _ I ! 3 HAA # 0A" 0,90 Expiration Date: 1. GSNERAL INFORMATION Complete legal description Lot 11 • Block 10 • Rabbit Creek Heights Subdivision Location (site address or directions) 8340 Harwood Cir. Anchorage, AK Current Property 11 owner.(s) Mark Dunne Day phone 786-7310 Mailing address c/o Bond, Stephans, & Johnson 3000 A st. Ste. 200 9 Lending agency Day phone Mailing address Real Estate Agent Day phone. Mailing Address Unless otherwise requested, HAA will be held by DSD for pickup. 7 / a 3 /O t/ 2. NUMBER OF BEDROOMS: 3 3. TYPE OF WATER SUPPLY: Individual Well Individual Water Storage ❑ Community Class Well ❑ Public Water System ❑ TYPE OF WASTEWATER DISPOSAL: Individual On-site Individual Holding tank ❑ Community On-site ❑ Public Sewer ❑ The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of Health Authority Approval (HAA) based only upon the representations given in paragraph 4 by an independent professional civil engineer "registered in the State of Alaska. Certificates of Health Authority Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues HAAs upon request to homeowners. Certificates of Health Authority Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water sample results. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Health Authority Approval Guidelines for this application, shows that the on- site water supply and/or wastewater disposal system is(are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and. regulations in effect at the time of installation. Name of Firm S & S Engineering Phone 694-2979 Address 17034 N. Eagle River Loop Ste. 204 Eagle River, AK 99577 Engineer's Printed Name Robert C. Qgyan Date 7 % t /0 Y S 5. DSD SIGNATURE F ROBERT C. COWAN %WQ 0 CE -8801 r+fir, Approved for �✓ bedrooms. f r �0 f"; -,... ,:,,•` �� Disapproved. it%<ta�„„may». Conditional approval for bedrooms, with the following stipulations: Attachments: HAA Checklist X Maintenance Agreements Septic System Advisory Supplemental Engineer's Report Well Flow Advisory Other By: Original Certificate Date: % — 2, 3--O L/ (Rev. 01/02) lvxU11A Developr On -Sit )rage lartment gram 5f9-6650 .' I.T t If A, B, or C provide PWSI,D,# _ Well Log VN (aSJx% Sanitary seal /N) s Wires properly protected" 0, Y* S ft ` Cased to ft L Casing height (aboveground) a f in sR0 �, AT INSPECTI �� • ft. 'ft 9 -P.M. •-`%�, '.h L ,'.d:°.x"' `���' #•'aw..'a""„���F�,�,'S•.54�,� �"'"<.a ter:.' ,r '. �i �•�iF%'�,`so-vik."a��.+�`m`�'���',+r�`.°"'e��'v��*„,sv'r'�° ias{�.,��,., :,_.,s _ a'r,;',!.. colonies/100 ml. Nitrate t.) 6 mg./I. Other bacteria colonies/100,m 1. v yr wr $ r d a. ,.;, ,.ryr;. w •rf-:as, .r' Collected by:,.--. d Ne 304 A.� p `".wC"<hk�"n+n$+`w"3, Y'+�''�i�.N%, a jG`+c ...'(z•. 0.r:: Fs :v v.,. Pifer �c�34R Gt, -7 N) ;real Date installed % tis +b z y:'ro and�`,L*r-.ZU9 m.� .a4} u>"..'=xe�W s,.me r. m'a^ a ,i^a, wy;,�Y.^x✓'S° M1 a h%��"�`ye "" '. ,! gal. Number of Compartments Cieanouts (yN) afro N)J Depression over tank (Y(ry) r0 High water alarm (Y® F/ Pumper' YvOaru"y-n PIMP NG F/zo / ' °I Sod rating (g p d./ft2 or ft2/bdrm y So, System type, 7 Cr c y . �%'��rv�''+ rr„tdwx'�,'�a"'�,4"e�fc.'+'khYKiW:wtb`�x"�rdtf.eQa✓.[S�R`,58rfa' i"?�+h .. •'T' � •• �. ft W dth - ft: Gravel below pipe _ ft R0,040 -s) ft Eff absorption area ssa ft2 Monitoring tube yE' Depression over field yes S o N Results Fabedrooms �sarpfion fe before est � in. Wateradded�77ga1 Newdepth� J'�n `min. Feria f(wd, eptfi � o in: Absorption rate >_ `Y 3'0 g p.d n 4raa man nacf -mo ( � Voe ". �" . i✓�ivh%- • VOS.�QiVe a e off level High water alarm level at in. tested Meets alarm & circuit requirements? _ Property line s Absorption field Water service line %c) Surface water / o o rf cords that the above systems are inµ�� A HAA guidelines in effect on this date t cosex c: cawaN' i f me w'Ii✓ Waiver Fee $ O r �O Date of Payment Y« AReceipt Number SGS Ref.# 1043638001 Client Name S & S Engineering Project Name/# Rabbit Creek Heiabts Client Sample ID Lot 11 Block 10 Matrix Drinking Water Sample Remarks: Laboratory Analysis Report All Dates/Times are Alaska Standard Time Printed Date/Time 06/29/2004 7:02 Collected Date/Time 06/23/2004 13:45 Received Date/Time 06/23/2004 14:10 Technical Director Stepyen C. Ede Released B� Allowable Prep Analysis Init Parameter Results AQL Units Method Container ]D 1 ntits Date Date Waters Department Nitrate -N 1.16 0.100 Microbiology Laboratory Total Coliform 0 mg/L EPA 300.0 B (<=10) 06/24/04 JJB coUl00mL SM209222B A (<=1) 06/23/04 DKC ,; ``d' ie ?', 3e.. �� .I abontory Division 200 West Potter Mve. Anchorage AK 99516 1605 r 19071502 2343 1 (9071 561 5301 wwwsgsenvlronmental corn Member 0 0e SGS Group lSp661E GEn2rale de Surveillance) LOT 19A i LOT 20A HARW00P-:-:7:DiLi7 .:: `t BASIS -I _EARING HARWOOD. CIRCLE N894C55".E: :' 11' (M) \: j F4mtr 22:s' Of v„^ OR c N M Lot 14A LOT 75A N i easements of rights-of-way, EXCEPT AS SHOWN OR NOTED HEREON. Ilnu `00 a N N PREPARED FOR: a ®We LOT 12A z I No data hereon should be used for positioning additional structures, at I. F4mtr 22:s' Of v„^ OR c N M Lot 14A LOT 75A N i easements of rights-of-way, EXCEPT AS SHOWN OR NOTED HEREON. SubdIv1S1011 R tat `00 a N N PREPARED FOR: a ®We LOT 12A z I 28.3' LOT 11A 23,405 sq. ft. 42.4' f ad As -Built for I Hereby certify that I have "surveyed the property and "£achfies described hereon and that the improvements situated thereon do not encroach on Block 1 OH Lot 11 A Z : Lot 14A LOT 75A encroach on the surveyed premises, a: d drat there a -c no at rt,t f i easements of rights-of-way, EXCEPT AS SHOWN OR NOTED HEREON. SubdIv1S1011 R tat Robert T. Kean, R.L.S. 3943-S Date PREPARED FOR: SCALE: EXCLUSIONS Marc Dunn 1" = 50' No data hereon should be used for positioning additional structures, at I. z:l \ for building fences, or for locating the boundary lines. It is the !_::::': DRAWN BY: CHECKED BY. responsibility of the owner to deter mine the existence of any easement KEAN & ASSOCIATES FBIII RTK or restriction that does not appear on the recorded subdivision plat 6927 Old Seward Hwy. and to verify that all improvements meet all subdivision covenants Suite 101 GATE of SURVEY: MOA GRID: and zoning ordinances. Anchorage AK 99518 05/24/04' 3341 tsJ:.: I LEGEND Recovered 2" Orange Plastic \ Cap Monument I Qs Septic Cleanout I —o/t/— Overhead Utility Line — x — Chain-link Fence (R) Record Information Per Replat ® Deck Gravel Drive / R S89'52'06"W 99.74' (R) i — -'_J o PP to' Eleo./Tele. Eoaement - ------ - - - - --- - - - - -- - - - - -- I LOT 13A LOT 9A LOT 10A ff; :.: ::I 0 444 t 0 .... 0... ... • �`� .0 ', ROBERT T. KEAN c's°•. / r No. 3943-SAr 15 "Fo . aq ....... ° PTt• 41, • O`ESSI CNA • t►nIJL•+• NOTES 1. This properly is within. the Municipality of Anchorage's Special Survey Assessment District I V96, which was formed to correct plat and survey errors within Rabbit Creek View and Rabbit Creek Heights Subdivisions. A Complaint and proposed Replat were filed with the Superior Court December, 1998 (Civil Action No.3AN- 98-11718). Final judgment on the revised Replat, dated March 31, 2004, was recorded as Serial No.2004-022267-0 Anchorage recording District, Third Judicial District, Alaska. 2. Property line locations shown are per the approved Replat which were determined using found monument locations and the intent of the original plat. 3. Recovered orange plastic caps were set in 2003 by Kean and Associates and represent property comers according to the approved Replat. SURVEYOR'S CERTIFICATE As -Built for I Hereby certify that I have "surveyed the property and "£achfies described hereon and that the improvements situated thereon do not encroach on Block 1 OH Lot 11 A adjacent property, that improvements on adjacent property do not Rabbit Crk Vlew arid. Rabbit C1"k Heights encroach on the surveyed premises, a: d drat there a -c no at rt,t f i easements of rights-of-way, EXCEPT AS SHOWN OR NOTED HEREON. SubdIv1S1011 R tat Robert T. Kean, R.L.S. 3943-S Date PREPARED FOR: SCALE: EXCLUSIONS Marc Dunn 1" = 50' No data hereon should be used for positioning additional structures, for building fences, or for locating the boundary lines. It is the PREPARED BY: DRAWN BY: CHECKED BY. responsibility of the owner to deter mine the existence of any easement KEAN & ASSOCIATES FBIII RTK or restriction that does not appear on the recorded subdivision plat 6927 Old Seward Hwy. and to verify that all improvements meet all subdivision covenants Suite 101 GATE of SURVEY: MOA GRID: and zoning ordinances. Anchorage AK 99518 05/24/04' 3341 HEALTHAUTHORITY APPROVALS SEWER&WATER MAIN EXTENSIONS SEWER&WATER INSPECTION ENGINEERINGSTUDIES ANDREPORTS WELL INSPECTION & FLOW TEST SITE PLANS ROAD DESIGN SOIL TEST PERCOLATION TEST STRUCTURAL& MECHANICAL INSPECTIONS MUNICIPALITY OF ANCHORAGE Development Services Department P.O. Box 196650 Anchorage, AK 99519 REFERENCE: Lot 11, Block 10, Rabbit Creek Heights Subdivision It is requested that you issue a waiver from the well to the septic tank at 97'. Also request a waiver from the leachfield trench to the west property line at 5'. It appears that the leachfield trench is less than 5' from the septic tank. Since the tank is fiberglass, this does not cause concern over the possibility of the exterior tank surface being wet. Potential surfacing effluent or tank leakage would not flow towards the well. The well is uphill from the septic tank. Septic tanks are not considered a continuous source of contamination, as they are designed to be water tight. The fiberglass septic tank will not corrode eliminating concern over leakage from tank wall deterioration (corrosion). We do not anticipate any adverse effects on neighboring wells, septic systems, reserve areas or drainage patterns by the granting of these waivers. If you require additional information, please contact us. Sincerely, 4�114? Z<L Robert C. Cowan, P.E. RCC/bjj Enclosure ONSITE WASTEWATER DISPOSALSYSTEM DESIGN 17034 NORTH EAGLE RIVER LOOP • SURE 204 • EAGLE RIVER, ALASKA 99577 1 " = 40' WAIVER m SITE—PLAN Z ➢ SCALEmJ D W I S A DOxzn Cv I x o O m I iO �p O n III m mSA t ' N Abd I>DO L N O r,1 w O bJA Jy O I II r x NX CN Zy ~l oz mG) v ln- n0 D � 40 Cn ZO n EXISTING TRENCH No-nox O 10�� 15y N FLAT± w FLAT± w o 97' -� 4 ~ n 0 M WALL X ^I O RETAINING p ,�0• LA1 OmX IG -15% DRIVEWAY WM oz P9 00 on m i A O m Z H I m Z ➢ D W I � Cv I x o O m I A O n III t ' N L N O O x NICKLEEN STREET O --- ------ ------ - -- x I V1 I O I I I � I I �ZLI Mt nicipality of Anchorage P.O. Bos 196660 • Anchorage Alaska 99,519-66,50 • "Pelephone (907) 343.8301 • Fax (907) 343-8200 4700 Bragaw Street e Anchorage, Alaska 99607 wwra.ntuni.org Mayor Mark Begich Building Safety Division 7/22/2004 Robert Cowan S&S Engineering 17034 North Eagle River Loop Rd Eagle River, AK 99577 Subject: Waiver Request for Rabbit Creek Hts Block 10 Lot 11 Waiver Request #WR040047 Parcel ID #020-113-36 Dear Bob Cowan: Q C rTY Your request for a waiver of the required 100 feet horizontal separation from the septic tank to private well has been approved. The approved separation distance is 97.0 feet. Also the required 10 foot septic to lot line has been approve for a 5 foot separation. This waiver approval applies to the existing' septic tank to private well and the existing septic field to property line separation only. Any future upgrade to the on-site wastewater disposal system will require all separation distances be met or another approval from this department. If there are any further concerns or questions regarding this waiver, please call our office at 343-7904. Sincerely, rJoeGoodall Civil Engineer On -Site Water & Wastewater Program Community, Security, Prosperity W R#. 04 Date Rea Legal De: Engineer. Applicarif Waiver R, Criteria: .-•rMV, r Waiver is List Coni) ­�MunicipaTity of Anchorage _ Development Serv"ic"es Department Building Safety Division On -Site Water and Wastewater Program ` 4700 Bragaw. Street s a e , r P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchoiage.ak.us ,.. ... (907)'343-7904 Waiver"Review'Worlisheet PID#: b2i7=1`13''=36" -' HA#i _6db°IOT -' Permif# ptioh: RAbit°Creek & S Ennineering By: 5: of A- a." E. c. W#rErt 'TA6c,E rnlrS 8 door 'DECO TREtrcH ASScJ+'+E DEPTH W W W 000 SOIL. SoR[irr6 ss� n"A 90 tv ' (I -z- lZ0 0 -Fu 10 41 --us" . (Srdn wE o 1riA2o 9� •fo lI z 3EorsoG l� 1N�7E4.._Ti+?$LE OR&PeeAr7 %#cvo2/arNr� TJ S S LE1TEr{ / }r£n 6.0 �-V y zvtA 200q I.AG4o 15 Ue7 Kh01E A%T' , f%ORr�ONTl4L SEPA�2R r Wry wm,.,.,�as�miw�.oe.er;�.w�m,�waw�.�uwr• .. .......... .... .._ 2•S 9} `FaE7- o r-►�-� _-----_ 2 / Sr n CONG LVS;0 CRgrvr ` WRIV€2 r