Loading...
HomeMy WebLinkAboutPOGGAS BLK 6 LT 5Poggas Block 6 Lot 5 #018-071-11 '1� ' D MUnic pa Ity o Anchorage (• Development Services Department _Building Safety Division On -Site 4.1 . i Water & Wastewater Program 4700Box w Street 19 P.O. Box 19 650/ Anchorage, AK 99519519 .6650 //✓1 www.munf.org/onsite (907)343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL FOR A SINGLE FAMILY DWELLING Parcel l.D. COSA# UI D&A 1. GENERAL INFORMATION Expiration Date: / — .z. 5" O 8 Complete legal description Location (site address) Current Property owner(s) Mailing address Lending agency Mailing address Real Estate Agent Mailing address POGGAS SUBDIVISION: LOT 5. BLOCK 6 12918 HACE STREET ' ANCHORAGE, AK 99515 KATHEREEN HAMANN Day phone 345-4462 12918 HACE STREET • ANCHORAGE. AK 99515 Day phone FSBO Day phone Unless otherwise requested, COSA will be held by DSD for pickup. 2. NUMBER OF BEDROOMS: 3. TYPE OF WATER SUPPLY: Individual Well 0 Individual Water Storage ❑ Community Class Well ❑ Public Water System ❑ TYPE OF WASTEWATER DISPOSAL: Individual On-site ❑ Individual Holding tank ❑ Community On-site ❑ Public Sewer 0 The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 4 by an Independent professional civil engineer registered in the State of Alaska. Certificates of On -Site Systems Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also Issues COSAs upon request to homeowners. Certificates of On -Site Systems Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water samples. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my Investigation, based on procedures outlined In the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage riles and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm GARNESS ENGINEERING GROUP, Ltd. Phone 337-6179 Address 3701 E. TUDOR ROAD, SUITE 101 * ANCHORAGE. AK 99507 Engineer's Printed Name Date ���a C rt�n,�E Engineer's Comments: In conducting this evaluation, GEG, VD. attempted to provide a thorough, conscientious engineering anaWs of the system In accordance with ADEC and MOA O F A�� 1) DSD Guidelines d Regulations. The reported results described the performance of the r �t»,. •' Sett system under the conditions encountered at the time of the test, and separation ` r if distances measured to readily Identifiable features. The operational life of all wells and , r �� 9 septic systems depend on the local soils condition, groundwater levels that may o fir' 4.9 T,= • 41A t fluctuate during the year, and the water usage of the family being served by the system. These conditions are outside the control of the evaluator of the system. Satisfactory test % • ^'% `" "' ' results do not guarantee future erformance of system, nor do the : M.',. t.iCAi�$ ;;nom ; 8 P y they there are no hidden defects or encroachments. GEG, LTD. can therefore not provide Or �J,}'•• C=11135 i any warranty or future estimate ofhow long the system will continue to meet the �t S,� ✓•� Z�•�?� operational requirements of the ADEC or MOA DSD. The content of this report Is for report by any the sole benefit of the owner listed above. Any reliance upon or use of this otherperson or party is not authorized, nor will it confer any legal right whatsoever. 5. DSD SIGNATURE;y0 `%�QPv••••'•••` •.i Approved for bedrooms. J . ONSITE Disapproved. WATERAND •; WASTEWATER Conditional approval for bedrooms, with the fllowin9 stipulations-, PROGRAM •��Qj/ �//illJlll) l l 11)Y1S_ Attachments: COSA Checklist Arsenic Advisory Septic System Advisory Maintenance Agreements Well Flow Advisory Supplemental Engineer's Reort Nitrate Advisory Other By: (R". roe) Original Certificate Date: / 0 - a K- 0 % Municipality of Anchorage • Development Services Department Building Safety Division Onsite Water 6 Wastewater Program 4700 Shaw Street P.O. Box 190650 Anchorage. AK 99519.6650 www.muni.org/onsito (907)343.7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST Legal Description: POGGAS SUBDIVISION: BLOCK 6. LOT 5 Parcel ID: 019-071-11 A. WELL DATA 'BASED UPON SURROUNDING WELL LOGS **SEE ATTACHED LETTER Well type PRIVATE If A, B, or C provide PWSID# N/A Well Log (Y/N) NO Date completed 1954 Sanitary seal (Y/N) YES Wires property protected (Y/N) YES Total depth <100 ft. Cased to •40+ ft, Casing height (above ground) "'3 in. FROM WELL LOG Data of test Static water level .3o ,�y tt ft. Well production g.p.m. WATER SAMPLE RESULTS: Coliform 0 colonies/100 ml. Arsenic: 10.6 ug./L. AT INSPECTION 7/6/2007 33 ft, 4.3 g.p.m. Nitrate ND mg./L. Other bacteria 0 colonies/100 mi. Date of sample: 7/5/2007 Collected by: GEG Ltd. B. SEPTIC/HOLDINGTANK DATA PUBLIC SEWER Tank Type/Material Tank size gal. Number of Compartments Foundation deanout (YM) Date installed tank (Y/N)_ High water alarm (Y/N) C. ABSORPTION FIELD DATA PUBLIC SEWER Date installed Soil rating (g.p.d./ft'or ft'/bdrm)_ System type Length ft. Width ft. Gravel bel pt3' ft. Total depth ft. Eff. absorption area_ ft' Monitoring to _ Depression over field Data of adequacy test Results ail) For bedrooms Fluid depth in absorption field before _ in. Water added _ gal. New depth _in. Elapsed Time:—Final fluid depth _ in. Absorption rate >_ g.p.d. treatment (past 12 mo.) (Y/N 3 type) If yes, give date D. LIFT STATION Date installed Size in gallons Manhole/Acoess (Y/N "Pump on" level at_in. "Pump off" I High water alarm level at in. Datu Cycles tested Meets alarm 8, circuit requirements? E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on kriNLA On adjacent lots 100'+ Absorption field on lot N/A Public sewer main 50'+ On adjacent lots 100'+ Public sewer manhole/cleanout 50'+ Sewer /septic service line 16 +/— Holding tank N/A Animal containment areas 50'+ Manure/animal excrete storage areas 100'+ SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: PUBLIC SEWER Building foundation Water main Property line Surface water PUBLIC SEWER SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line Water service line F. COMMENTS G. ENGINEER'S CERTIFICATION Building Wells on adjacent lots I certify that I have determined through Bald inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. Engineer's Printed Name JEFFREY A. GARNESS Date -*h. 104 COSA Fee S 113b O U Date of Payment 7L Z I V 7 Receipt Number (Rev. 71105) Driveway, parking/vehicle storage Waiver Fee $ Date of Payment Receipt Number Municipality of Anchorage Development Services Department Building Safety Division On -Site Water 6 Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519.6650 www.muni.org/onsite (907)343-7904 CERTIFICATE OF ON-SITE SYSTEMS FOR A SINGLE FAMILY DWELLING Parcel I.D. hl -URI- / I COSA# V 1-DA104 1. GENERAL INFORMATION Expiration Date: f-: " c - o Z Complete legal description Location (site address) Current Property owner(s) Mailing address Lending agency Mailing address Real Estate Agent Mailing address POGGAS SUBDIVISION: LOT 5. BLOCK 6 12918 HACE STREET • ANCHORAGE. AK 99515 KATHEREEN HAMANN Day phone 12918 HACE STREET * ANCHORAGE. AK 99515 Day phone FSBO Day phone Unless otherwise requested, COSA will be held by DSD for pickup. 2. NUMBER OF BEDROOMS: 4 3. TYPE OF WATER SUPPLY: Individual Well E Individual Water Storage ❑ Community Class Well ❑ Public Water System ❑ 345-4462 TYPE OF WASTEWATER DISPOSAL: Individual On-site ❑ Individual Holding tank ❑ Community On-site ❑ Public Sewer 0 t The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of On -Site Systems Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues COSAs upon request to homeowners. Certificates of On -Site Systems Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water samples. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineers work. 4. STATEMENT OF INSPECTION BY ENGINEER As certirred by my seal affixed hereto and as of the validation date shown below, I verify that my Investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verily that based on the information obtained from the Municipality of Anchorage rites and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of Installation. Name of Firm GARNESS ENGINEERING GROUP. Ltd. Phone 337-6179 Address 3701 E. TUDOR ROAD. SUITE 101 + ANCHORAGE, AK 99507 Name Engineer's Comments: Fa In conducting this evaluation, GEG, VD. attempted to provide a thorough, conscientious engineering analysis of the system in accordance with ADEC and MOA DSD Guidelines B Regulations. The reported results described the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readilyldontifiablo features. The operational life of all wells and septic systems depend on the local soils condition, groundwater levels that may fluctuate during the year, and the water usage of the family being served by the system. These conditions are outside the control of the evaluator of the system. Satisfactory lost results do not guarantee future performance of the system, nor do they guarantee that there are no hidden defects or encroachments. GEG, LTO. can therefore not provide any warranty or future estimate of how long the system will continue to meet the operational requirements of the ADEC or MOA DSD. The content of this report Is for the sole benefit of the owner listed above. Any reliance upon or use of this report by any other person or party Is not authorized, nor will it confor any legal right whatsoever. 5. DSD SIGNATURE L'._� Approved for _ bedrooms. Disapproved. Date/Oq• aooaoppp Qoo �F.• �F'A ••.•��p0 I �. .... ... .� JI.. .t. ... a A. ess: Conditional approval for bedrooms, with the Illowing stipulations: Attachments: *V-e••••••-�'Io ON SITE WATER AND WASTEWATER PROGRAM O •, COSA Checklist v Arsenic Advisory Septic System Advisory Maintenance Agreements Well Flow Advisory Supplemental Engineer's Reort Nitrate Advisory Other Original Certificate Date: _ to) (Rev 1105) Municipality of Anchorage Development Services Department Building Safety Division On -Sae Water 6 Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-66W www.murd.wglonsite (907)343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST - 4W Legal Description: POGGAS SUBDIVISION: BLOCK 6. LOT 5 Parcel ID: 0 15t- 07 /- // A. WELL DATA *BASED UPON SURROUNDING WELL LOGS ""SEE ATTACHED LETTER Well type PRIVATE If A. B, or C provide PWSID# N/A Well Log (Y/N) NO Date completed 1954 Sanitary seal (Y/N) YES Wires properly protected (Y/N) YES Total depth <100 ft. Cased to •40+ ft. FROM WELL LOG Date of test Static water level _ ��Y ft. O Well production N g.p.m. WATER SAMPLE RESULTS: Coliform 0 colonies/100 mi. Arsenic: 10.6 ug./L. Casing height (above ground) •'3 in. AT INSPECTION 7/6/2007 33 ft. 4.3 g.p.m. Nitrate NO mgJL. Other bacteria 0 colonies/100 ml. Date of sample: 7/5/2007 Collected by: GEG Ltd. B. SEPTIClHOLDINGTANK DATA PUBLIC SEWER Tank Type/Material Tank size gal. Number of Compartments Foundation cleanout (Y/N) Pumper Date Installed tank (Y/N) _ High water alarm (Y/N) C. ABSORPTION FIELD DATA PUBLIC SEWER Date installed Soil rating (g.p.d./ft or ft'/bdrm)_ System type Length ft. Width ft. Gravel bel ft. Total depth ft. Eft. absorption area_ ft' Monitoring to Depression over field Date of adequacy test Results eil) For bedrooms Fluid depth in absorption fleid before _ in. Water added _gal. New depth _in. Elapsed Time: Final fluid depth _ in. Absorption rate >= g.p.d. treatment (past 12 mo.) (Y/N 8 type) If yes, give date D. LIFT STATION Date installed Size in gallons Manhole/Access (Y/N "Pump on" level at _in. "Pump off' I High water alarm level at in. Datum Cycles tested Meets alarm & circuit requirements? E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/ltft station on lot N/A Absorption field on kri N/A On adjacent kits 100'+ On adjacent lots 100'+ Public sewer main 50 + Public sewer manhole/cleanout 50'+ Sewer /septic service line 16' +/— Holding tank N/A Animal containment areas 50'+ Manureianimal excrete storage areas 100'+ SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOTTO: PUBLIC SEWER Building foundation Property line Water main Surface water. ftils4wedrdC01[lots PUBLIC SEWER SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line Building foundation Water service line r Driveway, parking/vehicle storage Wells on adjacent lots F. COMMENTS G. ENGINEER'S CERTIFICATION 1 certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. Engineer's Printed Name JEFFREY A. GARNESS ` Date .' 1.1 n 4 COSA Fee S 113 (1 O U Date of Payment %/ a Receipt Number. (Rw. 11ft) Waiver Fee E Date of Payment Receipt Number Municipality of Anchorage aea s, • Development Services Department Building Safety Division e On -Site Water and Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907)343-7904 Arsenic Advisory Certificate of On -Site Systems Approval # 070264 A Certificate of On -Site Systems Approval inspection and test of potable water was recently conducted on the well water supply on Block 5, Lot 6 of Poggas Subdivision. This inspection revealed an arsenic concentration of 10.6 micrograms per liter (ug/L) for the property's well water sample. The Environmental Protection Agency (EPA) has established a maximum contaminant level (MCL) of 10.0 ug/L for public drinking water systems. While private wells are not subject to this regulation, EPA standards are based on existing health information and can therefore be used to gauge the relative quality of water from private wells. Information on arsenic is available from the On -Site Water and Wastewater Program website (www.muni.or /og nsite) or at 343-7904. This advisory must be attached to all copies of the subject Certificate of On - Site Systems Approval. Jeff Garness From: Jim Sullivan [apw@gci.net] Sent: Sunday, August 05, 2007 7:32 PM To: Jeff Garness Subject: FW: Hace 12918.doc From: Jim Sullivan [mailto:apw@gci.net] Sent: Sunday, August 05, 2007 7:29 PM To: 'Jim Sullivan' Subject: RE: Hace 12918.doc From: Jim Sullivan [mailto:apw@gci.net] Sent: Friday, August 03, 2007 6:10 PM To: JeffCagarnessengineering.com Subject: Hace 12918.doc Susan Oswald E. 12)l P Have /n 8-2-071 %erified casing depth 30'+ with no perfor L,.ns. also exlended the well head to 12" and enclosed the v, -;res wit i conduit. : Thanks Jim Sullivan No virus found in this outgoing message. Checked by AVG Free Edition. Version: 7.5 416 / Virus Database: 269.11.2/933 - Release Date: 812/2007 2:221'M \o virus found in this outgoing message. Checked by AVG Free Edition. Version: 7.5.4'61 Virus Database: 269.11.6/938 - Release Date: 8'.5.2007 4.16 PNt I .x/89 ° s •40„� � .�o. o z o 33Z 23.2 14- � �i CO ,ctousE Z4 24- to= ! 44L � oft 4i Ott st %E .890 s31 40••`✓ 0a 1%03: I hereby certify that I have surveyed the following described property: LOT S SLCC �o /✓0 C7 C7Iq S Sl / er,> and that no enc oa@mTts exist except as indicated. Exclusion Note: ,:,OF �F A It is the responsibility of the owner to detendne the existence of a easements, spm ty any : ,....., q �► covenants, or restrictions Which do not appear on the recorded subdivision plat. i,`�,.•�'•.•5,��� Under no cimmstances should any data hereon be used for construction or for/r C.) . establishing boundary or fence liens. V * ...9TH. Dated at Anchorage, Alaska, this day of Au(,, MARSHALL R. LS -6291 6291 ff MURAC11M Es> UMM a ASSOCIAM f •., e 212 E. International Airport Road Anchorage, Alaska 99502 ASBUILT •• • • • • • 1�a ��; ap �O.j� .. Phone (907)562-2153 >�e�a Seze J_9&4ul� a y .x/89 33j Za2 14t •..240„ EKrS>'/N/� a� iL C�DC� _ Sede,. I'ne ri COPY /90. l' X r tT/,./Ci /4 DGrt G 1�j j0' t.5 -: o Z4= P►�O1'i► ppp � 4, , 14 C'- L 89'.5"3 4 ., kv. /9 v 0 9 Z I hereby certify that I have surveyed the following described property: LOTS ,LOCK (_O -/0 C7C7AS Sl/jfD and that no encroachments exist except as indicated. Exclusion Note:0� Q It is the responsibility of the owner to determine the existence of any easements, covenants, or restrictions viAch do not appear -on the recorded subdivision plat. i�`��••�,.......,5�%'♦ Lbder no eircrostanc s should any data hereon be used for construction or for C7�� ' 4 establishing boundary or fence lines. h K ...9TH :9*tee Dated at Anchorage, Alaska, this - day of Atf(f 1OP,/ F'%�'•` •/•%f••�++�%••j r MARSHALL R. Ca27i8ACII110 acn= h AsXmA= ASBUILT 0r v;,• L5-6291212 E. International Airport Road +�Anchor e, Alaska 99502 Phone (907)562-2153 o0eeo GARNESS ENGINEERING GROUP, Ltd. vc cv �—r. 1_ •rte CONSULTANTS & GENERAL CONTRACTORS c: -r= July 18, 2007 Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Program P.O. Box 196650 Anchorage, Alaska 99519 Subject: COSA for Lot 5, Block 6, Poggas Subdivision To whom it may concern: Recently we inspected and then tested a private well on the subject property. The house was built in 1954 and we assume the well was drilled about the same time. The well is located in the basement of the dwelling, near the east wall. The wellhead is surrounded by a poured concrete basement floor. The static water level is 33 feet. There is no well log available. The lots around this one arc on public sewer and water. The nearest well we have information on is on Lot 19, Block 1, Thomas W. Sperstad. During a COSA application the engineer indicated the well casing was extended to 118' in 1996. North of this lot, on Lot 18, a well was drilled by Alpine Drilling in 1998. The driller's log shows casing beyond 40 feet (verified by telephone to Dave Harper). A new variable speed pump, well seal, and pressure tank were installed by Arctic Pump. The pump that was installed is only used for wells that are less than 100 feet deep. A well flow test produced 1000 gallons in 208 minutes. Allowing for 100 feet of casing at 1.48 gallons/feet of casing, this well is able to produce over 4 gallons per minute. Increasing the height of the well casing above the concrete floor will not provide substantially greater protection for the wellhead, and will be difficult to achieve. Inasmuch as this well was drilled years before the requirement for 40 feet of casing, and given the conditions found at the wellhead, we are requesting that no further work be done. Photographs of the wellhead and piping are attached. 3701 E. Tudor Road, Suitc 101 • Anchorage, Alaska 99507-1259 Ph: (907) 337-6179' Fax: (907) 338-3246 0 Website: gamessengineering.com Your file reflects that in 1977 the owner felt he was connected to the public sewer system but AWWU was unable to perform a dye test due to an address problem. On July 12, 2007, AWWU confirmed by dye test that the dwelling and a separate shop building are connected to the public sewer system. We requesting the issuance of a COSA for this property. Thank you for your time and consideration regarding this matter. 3701 E. Tudor Road, Suitc 101 • Anchorage, Alaska 99507-1259 Ph: (907) 337-6179 0 Fax: (907) 338-3246 • Websitc: garnessenginecring.com 164' - o�