HomeMy WebLinkAboutPOGGAS BLK 6 LT 5Poggas
Block 6
Lot 5
#018-071-11
'1� ' D
MUnic pa Ity o Anchorage
(• Development Services Department
_Building Safety Division
On -Site 4.1
.
i Water & Wastewater Program
4700Box w Street
19
P.O. Box 19 650/
Anchorage, AK 99519519 .6650 //✓1
www.munf.org/onsite
(907)343-7904
CERTIFICATE OF ON-SITE SYSTEMS APPROVAL
FOR A SINGLE FAMILY DWELLING
Parcel l.D. COSA# UI D&A
1. GENERAL INFORMATION Expiration Date: / — .z. 5" O 8
Complete legal description
Location (site address)
Current Property owner(s)
Mailing address
Lending agency
Mailing address
Real Estate Agent
Mailing address
POGGAS SUBDIVISION: LOT 5. BLOCK 6
12918 HACE STREET ' ANCHORAGE, AK 99515
KATHEREEN HAMANN Day phone 345-4462
12918 HACE STREET • ANCHORAGE. AK 99515
Day phone
FSBO Day phone
Unless otherwise requested, COSA will be held by DSD for pickup.
2. NUMBER OF BEDROOMS:
3. TYPE OF WATER SUPPLY:
Individual Well
0
Individual Water Storage
❑
Community Class Well
❑
Public Water System
❑
TYPE OF WASTEWATER DISPOSAL:
Individual On-site
❑
Individual Holding tank
❑
Community On-site
❑
Public Sewer
0
The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of On -Site Systems
Approval (COSA) based only upon the representations given in paragraph 4 by an Independent professional civil
engineer registered in the State of Alaska. Certificates of On -Site Systems Approval are required for the transfer
of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or
water supply system. DSD also Issues COSAs upon request to homeowners. Certificates of On -Site Systems
Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may
be reissued with new water samples. (Certificates may be reissued for a period of up to one year with valid water
samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system.
The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work.
4. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my
Investigation, based on procedures outlined In the Certificate of On -Site Systems Approval Guidelines for this application,
shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the
information obtained from the Municipality of Anchorage riles and from my investigation and inspection, the
on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal
and State codes, ordinances, and regulations in effect at the time of installation.
Name of Firm GARNESS ENGINEERING GROUP, Ltd. Phone 337-6179
Address 3701 E. TUDOR ROAD, SUITE 101 * ANCHORAGE. AK 99507
Engineer's Printed Name Date
���a C rt�n,�E
Engineer's Comments:
In conducting this evaluation, GEG, VD. attempted to provide a thorough,
conscientious engineering anaWs of the system In accordance with ADEC and MOA O F A�� 1)
DSD Guidelines d Regulations. The reported results described the performance of the r �t»,. •' Sett
system under the conditions encountered at the time of the test, and separation ` r if
distances measured to readily Identifiable features. The operational life of all wells and , r �� 9
septic systems depend on the local soils condition, groundwater levels that may o fir' 4.9 T,= • 41A t
fluctuate during the year, and the water usage of the family being served by the system.
These conditions are outside the control of the evaluator of the system. Satisfactory test % • ^'% `" "' '
results do not guarantee future erformance of system, nor do the : M.',. t.iCAi�$ ;;nom ;
8 P y they
there are no hidden defects or encroachments. GEG, LTD. can therefore not provide Or �J,}'•• C=11135 i
any warranty or future estimate ofhow long the system will continue to meet the �t S,� ✓•� Z�•�?�
operational requirements of the ADEC or MOA DSD. The content of this report Is for
report by any
the sole benefit of the owner listed above. Any reliance upon or use of this
otherperson or party is not authorized, nor will it confer any legal right whatsoever.
5. DSD SIGNATURE;y0
`%�QPv••••'•••`
•.i
Approved for bedrooms. J . ONSITE
Disapproved. WATERAND •;
WASTEWATER
Conditional approval for bedrooms, with the fllowin9 stipulations-, PROGRAM
•��Qj/
�//illJlll) l l 11)Y1S_
Attachments:
COSA Checklist
Arsenic Advisory
Septic System Advisory Maintenance Agreements
Well Flow Advisory Supplemental Engineer's Reort
Nitrate Advisory Other
By:
(R". roe)
Original Certificate Date: / 0 - a K- 0 %
Municipality of Anchorage
• Development Services Department
Building Safety Division
Onsite Water 6 Wastewater Program
4700 Shaw Street
P.O. Box 190650
Anchorage. AK 99519.6650
www.muni.org/onsito
(907)343.7904
CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST
Legal Description: POGGAS SUBDIVISION: BLOCK 6. LOT 5 Parcel ID: 019-071-11
A. WELL DATA 'BASED UPON SURROUNDING WELL LOGS **SEE ATTACHED LETTER
Well type PRIVATE If A, B, or C provide PWSID# N/A Well Log (Y/N) NO
Date completed 1954 Sanitary seal (Y/N) YES Wires property protected (Y/N) YES
Total depth <100 ft. Cased to •40+ ft, Casing height (above ground) "'3 in.
FROM WELL LOG
Data of test
Static water level .3o ,�y tt ft.
Well production g.p.m.
WATER SAMPLE RESULTS:
Coliform 0 colonies/100 ml.
Arsenic: 10.6 ug./L.
AT INSPECTION
7/6/2007
33 ft,
4.3 g.p.m.
Nitrate ND mg./L. Other bacteria 0 colonies/100 mi.
Date of sample: 7/5/2007 Collected by: GEG Ltd.
B. SEPTIC/HOLDINGTANK DATA PUBLIC SEWER
Tank Type/Material
Tank size gal. Number of Compartments
Foundation deanout (YM)
Date installed
tank (Y/N)_ High water alarm (Y/N)
C. ABSORPTION FIELD DATA PUBLIC SEWER
Date installed Soil rating (g.p.d./ft'or ft'/bdrm)_ System type
Length ft. Width ft. Gravel bel pt3' ft.
Total depth ft. Eff. absorption area_ ft' Monitoring to _ Depression over field
Data of adequacy test Results ail) For bedrooms
Fluid depth in absorption field before _ in. Water added _ gal. New depth _in.
Elapsed Time:—Final fluid depth _ in. Absorption rate >_
g.p.d.
treatment (past 12 mo.) (Y/N 3 type)
If yes, give date
D. LIFT STATION
Date installed Size in gallons Manhole/Acoess (Y/N
"Pump on" level at_in. "Pump off" I High water alarm level at in.
Datu Cycles tested Meets alarm 8, circuit requirements?
E. SEPARATION DISTANCES
SEPARATION DISTANCES FROM WELL ON LOT TO:
Septic tank/lift station on kriNLA On adjacent lots 100'+
Absorption field on lot N/A
Public sewer main 50'+
On adjacent lots 100'+
Public sewer manhole/cleanout 50'+
Sewer /septic service line 16 +/— Holding tank N/A
Animal containment areas 50'+ Manure/animal excrete storage areas 100'+
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: PUBLIC SEWER
Building foundation
Water main
Property line
Surface water
PUBLIC SEWER
SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO:
Property line
Water service line
F. COMMENTS
G. ENGINEER'S CERTIFICATION
Building
Wells on adjacent lots
I certify that I have determined through Bald inspections and
review of Municipal records that the above systems are in
conformance with MOA COSA guidelines in effect on this
date.
Engineer's Printed Name JEFFREY A. GARNESS
Date -*h. 104
COSA Fee S 113b O U
Date of Payment 7L Z I V 7
Receipt Number
(Rev. 71105)
Driveway, parking/vehicle storage
Waiver Fee $
Date of Payment
Receipt Number
Municipality of Anchorage
Development Services Department
Building Safety Division
On -Site Water 6 Wastewater Program
4700 Bragaw Street
P.O. Box 196650
Anchorage, AK 99519.6650
www.muni.org/onsite
(907)343-7904
CERTIFICATE OF ON-SITE SYSTEMS
FOR A SINGLE FAMILY DWELLING
Parcel I.D. hl -URI- / I COSA# V 1-DA104
1. GENERAL INFORMATION Expiration Date: f-: " c - o Z
Complete legal description
Location (site address)
Current Property owner(s)
Mailing address
Lending agency
Mailing address
Real Estate Agent
Mailing address
POGGAS SUBDIVISION: LOT 5. BLOCK 6
12918 HACE STREET • ANCHORAGE. AK 99515
KATHEREEN HAMANN Day phone
12918 HACE STREET * ANCHORAGE. AK 99515
Day phone
FSBO Day phone
Unless otherwise requested, COSA will be held by DSD for pickup.
2. NUMBER OF BEDROOMS: 4
3. TYPE OF WATER SUPPLY:
Individual Well
E
Individual Water Storage
❑
Community Class Well
❑
Public Water System
❑
345-4462
TYPE OF WASTEWATER DISPOSAL:
Individual On-site
❑
Individual Holding tank
❑
Community On-site
❑
Public Sewer
0
t
The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of On -Site Systems
Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil
engineer registered in the State of Alaska. Certificates of On -Site Systems Approval are required for the transfer
of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or
water supply system. DSD also issues COSAs upon request to homeowners. Certificates of On -Site Systems
Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may
be reissued with new water samples. (Certificates may be reissued for a period of up to one year with valid water
samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system.
The Municipality of Anchorage is not responsible for errors or omissions in the professional engineers work.
4. STATEMENT OF INSPECTION BY ENGINEER
As certirred by my seal affixed hereto and as of the validation date shown below, I verify that my
Investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application,
shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verily that based on the
information obtained from the Municipality of Anchorage rites and from my investigation and inspection, the
on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal
and State codes, ordinances, and regulations in effect at the time of Installation.
Name of Firm GARNESS ENGINEERING GROUP. Ltd. Phone 337-6179
Address 3701 E. TUDOR ROAD. SUITE 101 + ANCHORAGE, AK 99507
Name
Engineer's Comments:
Fa
In conducting this evaluation, GEG, VD. attempted to provide a thorough,
conscientious engineering analysis of the system in accordance with ADEC and MOA
DSD Guidelines B Regulations. The reported results described the performance of the
system under the conditions encountered at the time of the test, and separation
distances measured to readilyldontifiablo features. The operational life of all wells and
septic systems depend on the local soils condition, groundwater levels that may
fluctuate during the year, and the water usage of the family being served by the system.
These conditions are outside the control of the evaluator of the system. Satisfactory lost
results do not guarantee future performance of the system, nor do they guarantee that
there are no hidden defects or encroachments. GEG, LTO. can therefore not provide
any warranty or future estimate of how long the system will continue to meet the
operational requirements of the ADEC or MOA DSD. The content of this report Is for
the sole benefit of the owner listed above. Any reliance upon or use of this report by any
other person or party Is not authorized, nor will it confor any legal right whatsoever.
5. DSD SIGNATURE
L'._� Approved for _ bedrooms.
Disapproved.
Date/Oq•
aooaoppp
Qoo �F.• �F'A ••.•��p0
I
�. .... ... .�
JI.. .t. ...
a A. ess:
Conditional approval for bedrooms, with the Illowing stipulations:
Attachments:
*V-e••••••-�'Io
ON SITE
WATER AND
WASTEWATER
PROGRAM
O •,
COSA Checklist v
Arsenic Advisory
Septic System Advisory Maintenance Agreements
Well Flow Advisory Supplemental Engineer's Reort
Nitrate Advisory
Other
Original Certificate Date: _ to)
(Rev 1105)
Municipality of Anchorage
Development Services Department
Building Safety Division
On -Sae Water 6 Wastewater Program
4700 Bragaw Street
P.O. Box 196650
Anchorage, AK 99519-66W
www.murd.wglonsite
(907)343-7904
CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST
- 4W
Legal Description: POGGAS SUBDIVISION: BLOCK 6. LOT 5 Parcel ID: 0 15t- 07 /- //
A. WELL DATA *BASED UPON SURROUNDING WELL LOGS ""SEE ATTACHED LETTER
Well type PRIVATE If A. B, or C provide PWSID# N/A Well Log (Y/N) NO
Date completed 1954 Sanitary seal (Y/N) YES Wires properly protected (Y/N) YES
Total depth <100 ft. Cased to •40+ ft.
FROM WELL LOG
Date of test
Static water level _ ��Y ft.
O
Well production N g.p.m.
WATER SAMPLE RESULTS:
Coliform 0 colonies/100 mi.
Arsenic: 10.6 ug./L.
Casing height (above ground) •'3 in.
AT INSPECTION
7/6/2007
33 ft.
4.3 g.p.m.
Nitrate NO mgJL. Other bacteria 0 colonies/100 ml.
Date of sample: 7/5/2007 Collected by: GEG Ltd.
B. SEPTIClHOLDINGTANK DATA PUBLIC SEWER
Tank Type/Material
Tank size gal. Number of Compartments
Foundation cleanout (Y/N)
Pumper
Date Installed
tank (Y/N) _ High water alarm (Y/N)
C. ABSORPTION FIELD DATA PUBLIC SEWER
Date installed Soil rating (g.p.d./ft or ft'/bdrm)_ System type
Length ft. Width ft. Gravel bel ft.
Total depth ft. Eft. absorption area_ ft' Monitoring to Depression over field
Date of adequacy test Results eil) For bedrooms
Fluid depth in absorption fleid before _ in. Water added _gal. New depth _in.
Elapsed Time: Final fluid depth _ in. Absorption rate >= g.p.d.
treatment (past 12 mo.) (Y/N 8 type) If yes, give date
D. LIFT STATION
Date installed Size in gallons Manhole/Access (Y/N
"Pump on" level at _in. "Pump off' I High water alarm level at in.
Datum Cycles tested Meets alarm & circuit requirements?
E. SEPARATION DISTANCES
SEPARATION DISTANCES FROM WELL ON LOT TO:
Septic tank/ltft station on lot N/A
Absorption field on kri N/A
On adjacent kits 100'+
On adjacent lots 100'+
Public sewer main 50 + Public sewer manhole/cleanout 50'+
Sewer /septic service line 16' +/— Holding tank N/A
Animal containment areas 50'+ Manureianimal excrete storage areas 100'+
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOTTO: PUBLIC SEWER
Building foundation Property line
Water main
Surface water.
ftils4wedrdC01[lots PUBLIC SEWER
SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO:
Property line Building foundation
Water service line r Driveway, parking/vehicle storage
Wells on adjacent lots
F. COMMENTS
G. ENGINEER'S CERTIFICATION
1 certify that I have determined through field inspections and
review of Municipal records that the above systems are in
conformance with MOA COSA guidelines in effect on this
date.
Engineer's Printed Name JEFFREY A. GARNESS
`
Date .' 1.1 n 4
COSA Fee S 113 (1 O U
Date of Payment %/ a
Receipt Number.
(Rw. 11ft)
Waiver Fee E
Date of Payment
Receipt Number
Municipality of Anchorage
aea s,
• Development Services Department
Building Safety Division e
On -Site Water and Wastewater Program
4700 Bragaw Street
P.O. Box 196650 Anchorage, AK 99519-6650
www.muni.org/onsite
(907)343-7904
Arsenic Advisory
Certificate of On -Site Systems Approval # 070264
A Certificate of On -Site Systems Approval inspection and test of potable
water was recently conducted on the well water supply on Block 5, Lot 6 of
Poggas Subdivision. This inspection revealed an arsenic concentration of
10.6 micrograms per liter (ug/L) for the property's well water sample. The
Environmental Protection Agency (EPA) has established a maximum
contaminant level (MCL) of 10.0 ug/L for public drinking water systems.
While private wells are not subject to this regulation, EPA standards are
based on existing health information and can therefore be used to gauge the
relative quality of water from private wells. Information on arsenic is
available from the On -Site Water and Wastewater Program website
(www.muni.or /og nsite) or at 343-7904.
This advisory must be attached to all copies of the subject Certificate of On -
Site Systems Approval.
Jeff Garness
From:
Jim Sullivan [apw@gci.net]
Sent:
Sunday, August 05, 2007 7:32 PM
To:
Jeff Garness
Subject:
FW: Hace 12918.doc
From: Jim Sullivan [mailto:apw@gci.net]
Sent: Sunday, August 05, 2007 7:29 PM
To: 'Jim Sullivan'
Subject: RE: Hace 12918.doc
From: Jim Sullivan [mailto:apw@gci.net]
Sent: Friday, August 03, 2007 6:10 PM
To: JeffCagarnessengineering.com
Subject: Hace 12918.doc
Susan Oswald
E. 12)l P Have
/n 8-2-071 %erified casing depth 30'+ with no perfor L,.ns.
also exlended the well head to 12" and enclosed the v, -;res wit i conduit. :
Thanks
Jim Sullivan
No virus found in this outgoing message.
Checked by AVG Free Edition.
Version: 7.5 416 / Virus Database: 269.11.2/933 - Release Date: 812/2007 2:221'M
\o virus found in this outgoing message.
Checked by AVG Free Edition.
Version: 7.5.4'61 Virus Database: 269.11.6/938 - Release Date: 8'.5.2007 4.16 PNt
I
.x/89 ° s •40„� � .�o. o z o
33Z 23.2
14-
� �i CO ,ctousE
Z4
24-
to= ! 44L �
oft 4i
Ott st
%E .890
s31 40••`✓ 0a 1%03:
I hereby certify that I have surveyed the following described property: LOT S SLCC �o
/✓0 C7 C7Iq S Sl / er,> and that no enc oa@mTts exist except as indicated.
Exclusion Note: ,:,OF
�F A
It is the responsibility of the owner to detendne the existence of a easements,
spm ty any : ,....., q �►
covenants, or restrictions Which do not appear on the recorded subdivision plat. i,`�,.•�'•.•5,���
Under no cimmstances should any data hereon be used for construction or for/r C.) .
establishing boundary or fence liens. V * ...9TH.
Dated at Anchorage, Alaska, this day of Au(,,
MARSHALL R.
LS -6291 6291 ff
MURAC11M Es> UMM a ASSOCIAM f •., e
212 E. International Airport Road
Anchorage, Alaska 99502 ASBUILT •• • • • • • 1�a
��; ap
�O.j� ..
Phone (907)562-2153 >�e�a
Seze J_9&4ul� a y
.x/89
33j Za2
14t
•..240„ EKrS>'/N/�
a� iL C�DC�
_ Sede,. I'ne
ri COPY
/90.
l' X r tT/,./Ci
/4 DGrt G
1�j
j0'
t.5 -:
o
Z4=
P►�O1'i►
ppp
�
4, ,
14
C'-
L
89'.5"3
4 ., kv.
/9 v
0
9
Z
I hereby certify that I have surveyed the following described property: LOTS ,LOCK (_O
-/0 C7C7AS Sl/jfD and that no encroachments exist except as indicated.
Exclusion Note:0� Q
It is the responsibility of the owner to determine the existence of any easements,
covenants, or restrictions viAch do not appear -on the recorded subdivision plat. i�`��••�,.......,5�%'♦
Lbder no eircrostanc s should any data hereon be used for construction or for C7�� ' 4
establishing boundary or fence lines. h K ...9TH
:9*tee
Dated at Anchorage, Alaska, this - day of Atf(f 1OP,/ F'%�'•` •/•%f••�++�%••j
r MARSHALL R.
Ca27i8ACII110 acn= h AsXmA= ASBUILT
0r v;,• L5-6291212 E. International Airport Road +�Anchor e, Alaska 99502
Phone (907)562-2153 o0eeo
GARNESS ENGINEERING GROUP, Ltd.
vc cv �—r. 1_ •rte CONSULTANTS & GENERAL CONTRACTORS c: -r=
July 18, 2007
Municipality of Anchorage
Development Services Department
Building Safety Division
On -Site Water and Wastewater Program
P.O. Box 196650
Anchorage, Alaska 99519
Subject: COSA for Lot 5, Block 6, Poggas Subdivision
To whom it may concern:
Recently we inspected and then tested a private well on the subject property. The house
was built in 1954 and we assume the well was drilled about the same time. The well is
located in the basement of the dwelling, near the east wall. The wellhead is surrounded
by a poured concrete basement floor. The static water level is 33 feet.
There is no well log available. The lots around this one arc on public sewer and water.
The nearest well we have information on is on Lot 19, Block 1, Thomas W. Sperstad.
During a COSA application the engineer indicated the well casing was extended to 118'
in 1996. North of this lot, on Lot 18, a well was drilled by Alpine Drilling in 1998. The
driller's log shows casing beyond 40 feet (verified by telephone to Dave Harper).
A new variable speed pump, well seal, and pressure tank were installed by Arctic Pump.
The pump that was installed is only used for wells that are less than 100 feet deep. A
well flow test produced 1000 gallons in 208 minutes. Allowing for 100 feet of casing at
1.48 gallons/feet of casing, this well is able to produce over 4 gallons per minute.
Increasing the height of the well casing above the concrete floor will not provide
substantially greater protection for the wellhead, and will be difficult to achieve.
Inasmuch as this well was drilled years before the requirement for 40 feet of casing, and
given the conditions found at the wellhead, we are requesting that no further work be
done. Photographs of the wellhead and piping are attached.
3701 E. Tudor Road, Suitc 101 • Anchorage, Alaska 99507-1259
Ph: (907) 337-6179' Fax: (907) 338-3246 0 Website: gamessengineering.com
Your file reflects that in 1977 the owner felt he was connected to the public sewer system
but AWWU was unable to perform a dye test due to an address problem. On July 12,
2007, AWWU confirmed by dye test that the dwelling and a separate shop building are
connected to the public sewer system.
We requesting the issuance of a COSA for this property. Thank you for your time and
consideration regarding this matter.
3701 E. Tudor Road, Suitc 101 • Anchorage, Alaska 99507-1259
Ph: (907) 337-6179 0 Fax: (907) 338-3246 • Websitc: garnessenginecring.com