Loading...
HomeMy WebLinkAboutPOTTER HEIGHTS BLK 2 LT 9Potter Heights Block 2 Lot 9 #020-281-42 The electrical from the house to the panel is to be inspected by an electrician at the time of COSA Municipality of Anchorage Community Development Department Page 1 of 3 On-Site Water & Wastewater Program 4700 Elmore St. • P.O. Box 196650 Anchorage, AK 99519-6650 • http://www.muni.org/onsite • (907)343-7904 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: SW030084 PID Number: 020-281-42 New ® • Upgrade Name: ANTHONY STRUPULIS ABSORPTION FIELD Address: 8031 LITTLE DIPPER AVENUE 0 Deep Trench _t Shallow Trench 0 Bed • Mound ❑ Other Phone:No. of Bedrooms: (907) 269-0524 4 Soil Rating: 3.0 GPD/Sg. Ft Total Depth from original grade: SEE DWG. Ft LEGAL DESCRIPTION Depth to pipe invert from original grade: Gravel depth beneath pipe: Subdivision: SEE DWG. R. 0.59/0.60 R. Block: Lot: POTTER HEIGHTS 2 9 Fill added above original grade: SEE DWG. n. Gravel length: 40/40 FL Township: — Range: — Section: — Gravel width: Bede Number of lines. Distance between lines: SEPARATION DISTANCES 5n. — — Ft.Total Number trenches: To From Septic Tank Absorption Field Lift Station Holding Tank Public/Private Sewer Lines absorption area: 4.390er SD. FL of 2 Dist. between trenches: 10+ R. Well 1001+ 100'+ 1001+ — 25'+ TANK ❑ Septic ® S.T.E.P. ❑Holding ❑Other Surface Water 100'+ 100'+ 1001+ M nufacturer. ANCHORAGE TANK Capacity: 1500 Gal. Lot Line $+ 1 O'{. 5'+ — N/A Material: Number of compartments: FIBERGLASS 2 Foundation 51+ 10'+ 51+ — LIFT STATION/PUMP VAULT Curtain Drain Manufacturer: Capacity: NONE KNOWN ANCHORAGE TANK 1500/70 Col. Remarks: ADVANTEX SYSTEM— "Rump on" level at 'Pump off' level at: High water alarm at: THIS IS DOCUMENTATION OF ENGINEERING/CONSTRUCTION TIMER/ta TIMER/712" 44"/'32" ei Pump Yoke & Model: Electrical Inspections performed by: WORK COMPLETED IN SEPTEMBER 2003. CX?F�MGO PF3 PF-20. RISING SON ELECTRIC SEE ACCOMPANYING LETTER DATED FERUARY 27, 2014. PIPE MATERIAL to SCH40 House to tank D3034 Tdankrainfi Installer AKWWC eld Drainfield SCH40 C0/MT SCH40 Inspector GEC, Ltd. BENCH MARK (Assumed elevation) Inspection 105.64 Ft Dates: 1st 9/3/2003 2nd 9/4/2003 Location and Description: 3rd 9/4/2003 4th 9/5/2003 CONCRETE PATIO ON WEST SIDE OF HOUSE ® NW CORNER Community Development Department Approval Conditional approval: Date- ENGINEER'S SEAL aoo60000�4 ,Q.' 93'DOQ DA -j& Tile, ate ml- Ll cis,.. hem', to pane.( to be- fhspecjecl 6y elec nctbtf\ ® +He BF Gals"' Approved' LIN ac i - Date. 3 /Z/ti p P .i:f� . ness. �� OQ s-'' C °-- `. f‘i ^e,p��b .l!F;��a I �� ro fessioao PERMIT NUMBER: SW030084 AS -BUILT DRAWING w 2 N KND TESTHOLE GROUNDWATER 5.33' B.G. ON 9/4/03) PARCEL ID NUMBER: 020-281-42 8 \ FCO 8.46 37.30 STI 24.50 43.60 MH1 35.99 48.80 MH2 35.89 46.90 MTI 28.83 57.81 MT2 41.76 74.01 MT3 67.53 88.83 MT4 61.10 76.60 I 100' WELL RADIUS 1500 GALLON S.1:. -CP. TANK -- AND AX -20 ADVANTEX POD PUMP VAULT DRAINFIELDS [SEPTIC ARj POTTER HEIGHTS; BLOCK 2, LOT 10 S E: 1"= 40' GARNESS ENGINEERING GROUP, Ltd. CONSULTANTS & GENERAL CONTRACTORS 3701 E. TUDOR ROIL. 61111E 101 • NIUEIRIGE. 7I( 94507 • PHONE (907)337-6170 • FAX (90 PREPARED FOR: PHONE NUMBER: ANTHONY STRUPULIS 269-0524 LEGAL DESCRIPTION: POTTER HEIGHTS; BLOCK 2, LOT 9 C: ww .OTsw .1M PAGE NUMBER: 2 OF 3 TYPE OF WORK: DOCUMENTATION OF ENGINEERING & CONSTRUCTION WORK COMPLETED IN SEPTEMBER 2003 (Rev 01/05) DRAWN BY: PNB DATE: 2/5/14 PERMIT NUMBER: SW030084 AS -BUILT DRAWING PARCEL ID NUMBER: 020-281-42 FINAL GRADE = 108.03-108.07 TOP OF TANK = 103.03 TOP OF MANHOLE = 108.07 TOP OF MANHOLE = 108.17 INET INVERT OF PIPE = 102.06 OP OF TANK = 103.03 INVERT OF INLET = 103.19 1500 GALLON ADVANTEX' TANK BOTTOM OF PUMP VAULT = 100.19 FLOATS !TO UPPER TRENC tett TO LOWER TRENCH ORENCO PUMP VAULT KND TH TOP OF SAND 105.59 DRAINFIELD #1 T NAL GRADE = 108.57+ INSULATION FILTER FABRIC KND TH#2 DRAINFIELD #2 MT NAL GRADE = 105.48+ 2.5 TO 1 SLOPE ON DOWNHILL SIDE OF MOUND INSULATION FILTER FABRIC ORIGINAL GRADE ® HIGHEST t: 4.59 103.59 TOP OF SAND 1.25" PVC INVERT OF PIPE = 106.19 = 102.13 ORIGINAL GRADE 100.72-101.84 10' 7.25" PVC INVERT OF PIPE = 102.73 100.13 —RELATIVE ELEVATION OF BOTTOM OF TH = 93.59 (GW 0 99.26 ON 9/4/03. SEE ATTACHED LETTER) ORIFICE SIZE/SPACING IN PRESSURE LATERALS WAS NOT NOTED IN 2009 FIELD NOTES. ASSUMED TO BE 1/4" HOLES • 4' 0.C. RELATNE ELEVATION OF BOTTOM OF TH = 90.84 (GW 0 96.51 ON 9/4/03. SEE ATTACHED LETTER.) GARNESS ENGINEERING GROUP, Ltd. CONSULTANTS & GENERAL CONTRACTORS 3701 E RIGOR ROAD, SUITE 101 • ANCHORAGE, M( 99507 • p(OHE (907)337-8179 • FAX (907)558-3246 • WE09RE: rex.9ameeverginwin9.aom PREPARED FOR: ANTHONY STRUPULIS PHONE NUMBER: 269-0524 LEGAL DESCRIPTION: POTTER HEIGHTS; LOT 9, BLOCK 2 PAGE NUMBER: 3 OF 3 TYPE OF WORK: DOCUMENTATION OF ENGINEERING & CONSTRUCTION WORK COMPLETED IN SEPTEMBER 2003. 'Rev. 01/05) DRAWN BY: PNB DATE: 2/5/14 Rising Son Electric, Inc. 14916 Woodland Drive Eagle River, AK 99577 (907) -622-6777 Bill To Alaska Water & Wastewater 3701 E. Tudor Road, Suite 101 Anchorage, AK 99507 Invoice Date 10/08/2003 OCT v • - Invoice # 3827 wane P.O. Number Terms Due Date Project Due on receipt 10/08/2003 Quantity Description Rate Amount Service Call - POI i_ HEIDEITS (Ishor Only) 1— °1 f 7 2' 375.00 50.00 0.00% 375.00 50.00T 0.00 Total $425.00 PLOT PLAN _ AS 8UILT X SCALE 1' = 40' GRID 3839 Project No. 14-018A1 Lang & Associates, inc. 11500 Daryl Avenue, Anchorage, Alaska ne Registered Land Surveyors {oi) �- —8478 Fax kenOtangsurvey.com j jona hanOlangsurvey.aom I hereby certify that 1 have surveyed the following described -property LOT_9.8LOt:IS_ 2. POTTER _H_EIGNTS_SUSOMSION (PLATjF 81-224? Anchorage Recording District. Alaska, and that the improvements situated thereon are within the properly lines -and do not encroach-ontotheproperty adjacent thereto. that no improvements on the properly tying adjacent thereto encroach on the surveyed premises and that there _ are no roadways. _transmission lines or _atm visible easements on said property except as Indicated hereon. Dated this the Ih Day of Pahnlaattl 91414 , at Anchorage. Alaska it is the responslblly of the owner to determine the existents, m of any easements,. 99515-3049 GARNESS ENGINEERING GROUP, Ltd CIVIL & ENVIRONMENTAL ENGINEERS February 28, 2014 Municipality of Anchorage Development Service Department On -Site Water & Wastewater Program 4700 Elmore Road P.O. Box 196650 Anchorage, Ak 99519-6650 Attn: Deb Wockenfuss Ref: SW030084 - As -built documentation of septic system that was installed/completed in 2003 Ms. Wockenfuss: As we discussed recently, the subject property is owned by a Mr. Tony Strupulis. The septic system was designed (Advantex Cat III system) by KND Engineering and permitted by the MOA in April of 2003. The installation, and inspection of the installation, was performed in September 2003 by Alaska Water and Wastewater Consultants (AKWWC), which is the former name of Gayness Engineering Group Ltd. After completion of the installation in 2003, we requested and waited for the owner to provide us with the well -log, pump -log, and as -built survey so we could complete the MOA well and septic "Inspection Report". We requested this information several times (including a follow-up voice message on 10/4/06), and after not receiving it for some time archived the file away (assuming someone would contact us when the house was complete and they needed a "certificate of occupancy" (CO). In the winter of 2013 the MOA Onsite staff began to clean-up old files and it was noted that no as -built drawings and/or "Inspection Report" had been received for this well/septic installation. You had indicated that you had contacted Mr. Stupulis regarding the septic system installation and the as -built documentation. He indicated to you that the system was installed and that you should contact our office regarding documentation of the installation. You then contacted our office to see what we knew about the project. We pulled the file (quite frankly, we had completely forgot about the job) and confirmed that the as -built documents had yet to be finalized because we needed an as -built survey. At that time it was confirmed with Anchorage Tank and Welding that the system had yet to be started -up, because Mr. Stupulis had indicated to them that he has yet to occupy the home. We conveyed that to you and took no further action again, figuring that we would be contacted by Mr. Stupulis when he was close to getting his CO. We were contacted by you again in January of 2014 regarding the status of the as -built documentation. We asked you to confirm if a CO had yet to be issued and you were able to confirm it had not. We then made a call to Anchorage Tank and Welding and they confirmed that the Advantex system had yet to be started -up and was not being monitored with their Vericomm system. I then contacted Tony Stipulus and he indicated that he was still working on the house and the septic system was not being used yet. I told 3701 East Tudor Road, Suite 101 *Anchorage, Alaska 99507-1259 Phone: (907) 337-6179 * Fax: (907) 338-3246 * Website: www.gamessengineering.com Page 2 of 4 him that the MOA was looking for documentation of the septic system installation and that we should try to get the paperwork finalized. I conveyed to him that if he would get the as -built survey completed I would finalize the paperwork. The as -built survey was completed by Lang and Associates during the week of 2/8/2014 and forward to our office on 2/14/2014. Attached are the as -built drawings of the septic system. The installation inspections were performed by GEG employee Susan Oswalt. The following is a summary of pertinent points regarding the installation/documentation: ****************************************************************************** 1. Documentation of the Electrical Work: AKWWC was hired by Mr. Stupulis to install the septic system and perform the installation inspections as required by the MOA Onsite Department. As part of the installation AKWWC hired a licensed electrical contractor, Rising Son Electric, to perform the electrical work. Because no home was present at the time the septic system was installed, we mounted the Orenco Panel on a vertical 4" X 4" post immediately adjacent to the Advantex system. Rising Son did all of the wiring for the Orenco components. Mr. Stupulis later provided power from the house to the Orenco panel. In short, AKWWC is responsible for all electrical work from the Orenco Panel to the Orenco components and Mr. Stupulis is responsible for the electrical power (and phone line) from the house to the Orenco panel. Given the fact that the home is in the MOA "land use" area, electrical inspections are not performed by the MOA; therefore, it is standard practice to obtain a letter from the licensed electrician that did the work, stating that it was done in compliance with the applicable electrical codes. Due to the passing of time, we are now unable to obtain a letter from the electrician who did the work, because Rising Son Electric sold several years ago and has a new owner. When we discussed this issue several weeks ago, you indicated that you would be willing to accept the invoice from Rising Son Electric as documentation regarding the electrical work. I was able to find the invoice from Rising Son Electric and documentation that we paid the invoice. A copy of both documents is attached. 2. Location of Test Hole Relative to Primary and Reserve Trenches: The design prepared by KND and permitted by the MOA allowed for a large portion of each trench to be outside the 30 foot radius of KND TH#02-2. The reason for this was probably due to the following facts: • The percolation rate is 12.6 minutes per inch • The allowable application rate for CAT III system effluent is 5.0 gpd/ft2 • The required absorption area for a four (4) bedroom drainfield is 120 ft • The minimum required trench length for a 5 -wide trench with 6 inches of effective depth is 24 feet. • The actual trench lengths (primary and reserve drainfields) are 40 feet each. • In short, the majority of the trench that is outside the 30 foot radius of the test hole is redundant/bonus trench length. The KND showed the reserve trench slightly over the TH location. Given that the fact that the reserve drainfield was installed at the same time as the primary trench, we located the reserve trench 5 feet away from the test holes, so as to avoid placing the trench over un -compacted soil in the test hole The 120 ft2 of area required for each of the drainfields (primary and reserve) are encompassed within the 35 foot radius of the test hole pipe. 3. Groundwater Readings and Depth of Installation: The KND test holes were excavated on 8/27/2002 and groundwater readings were taken a week later on 9/3/2002. Per historical rainfall records, there was 0.92 inches of precipitation during the 5 days preceding the 9/03/2002 GWM reading by KND. 3701 East Tudor Road, Suite 101 * Anchorage, Alaska 99507-1259 Phone: (907) 337-6179 * Fax: (907) 338-3246 *Website: www. garnessengineering.com Page 3 of 4 This is a fairly intensive amount of rainfall during such a short period of time. The KND readings on 9/03/2002 indicated groundwater was 3.3 feet below grade in TH#2. During the drainfield installation's on 9/04/2003, Susan Oswalt documented groundwater at 5.33 feet (64 inches) below grade in TH #2. Groundwater monitoring readings taken from monitoring tubes placed vertically in an excavated hole (backfilled with un -compacted soil) are subject to artificially high readings until the soil has had some time to re -compact. The loose/disturbed soil and lack of vegetative mat around the test hole provides little impedance to surface runoff running into/around the test hole. The loose soil around the GWM pipe and the intense rainfall preceding the groundwater readings on 9/03/2002 likely resulted in erroneous, but conservative, groundwater readings by KND. Due to the passage of time, the conversations that took place between the MOA, myself, and Susan Oswalt during the installation can only be speculated, but it is our assertion that we obtained MOA verbal authorization to modify the system depth. Based upon Oswalt's readings, the design was revised to place the top of the sand in the lower drainfield at 0.29 feet above OG (highest OG on uphill side of trench), rather than 1 foot above OG as proposed in the KND design. Based upon GEG's groundwater readings, the following separations have been provided between the bottom of the drainrock (or top of filter sand) in each trench and groundwater: • Upper Trench GEG groundwater reading on 9/04/2003: 6.3+ feet • Lower Trench - GEG groundwater reading on 9/04/2003: 5.6 feet to 6.7 feet The adjacent property (Potter Heights, B2, L10), has a dual trench system on it. There were two test holes excavated for the design. On 9/20/1995 groundwater was encountered at 4.5 feet below grade in one test hole and 5.5 feet below grade in the other test hole. These groundwater readings are consistent with the readings taken by GEG in September of 2003. It is important to recognize that this is a CAT III advanced treatment system. Based upon Alaska test data, the effluent BOD and TSS numbers are consistently below ADEC secondary standards (30 mg/L) and the un -disinfected effluent has fecal Coliform reductions of 95% or more. In short, the effluent from a CAT III system is of such quality that a reduced separation distance to groundwater is fully justified if deemed necessary by your department. 4. Size of Orifices in pressure lines: During the installation, the decision was made to use pressure distribution rather than 4 inch perforated pipe in the trenches. This will allow for better distribution of the effluent along the length of the trenches and avoid creating any concentrated hydraulic loading along the trench length reducing the potential for daylighting out of the mound. Susan Oswalt did not note the orifice spacing or size on her September 2003 field notes. The construction superintendents field notes are unavailable. Neither person has worked for GEG for a number of years. It is reasonable to assume that during the installation I was probably contacted by Susan Oswalt or the construction superintendent and asked what the orifice size/spacing should be. I probably told them to use '''A" holes and space them at 4 feet on center. There is a separate pressure line coming out the Orenco pump vault for each trench. There are also isolation valves inside the pump vault so flow can be diverted to either trench or both trenches at the same time. 3701 East Tudor Road, Suite 101 * Anchorage, Alaska 99507-1259 Phone: (907) 337-6179 * Fax: (907) 338.3246 * Website: www. garnessengineering.com Page 4 of 4 5. Side Slopes on the Mound: The MOA code requires 3:1 side slopes or less on mounded systems. The final slope grades were not noted in our 2003 field notes. An inspection was performed recently and final grade shots were taken. The entire mound is now vegetated and has slopes of roughly 2.5 to 1. In short, the slopes are slightly steeper than allowed by the code. Given the effluent quality (CAT III system) and the presence of MOA sand below the drainfield, the effluent will rapidly migrate downward to an elevation that is at least 4.5 feet below the top of the mound. From this elevation, the effluent would have to travel laterally approximately 25 feet in order to daylight out of the mound. Given the porosity of the insitu soil below the drainfields, significant lateral migration of the effluent is unlikely. Given these facts, we are requesting that the MOA approve the installation with the existing side slopes. Once in use, the CAT III system will be inspected regularly as required by MOA code. If daylighting is observed, additional fill can be imported so as to create more gradual side -slopes on the downhill side of the mound. 6. Closing: The subject installation was completed in 2003 and the system has been available for beneficial use by the owner since that time; however, it is my understanding that he has yet to occupy the home. Following completion of our work in 2003, we have not performed any additional engineering or construction work on this system, except some minor work in August of 2005 to seal a leaking manhole riser. This letter, the "on-site wastewater inspection report", as -built drawings, and application of my professional engineering stamp is to document the construction and engineering work completed in 2003. If you have any questions regarding this report or the as -built drawings, please contact me via phone or email. 3701 East Tudor Road, Suite 101 *Anchorage, Alaska 99507-1259 Phone: (907) 337-6179 * Fax: (907) 338-3246 * Website: www. gamessengineering.com MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water 8 Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL. SYSTEM / WATER SUPPLY PERMIT Initial Permit Number: SW030084 Legal Description: Potter Heights Block 2 Lot 9 0 Design Engineer: 0070 KND Engineering Owner Name: Tony Struputis Owner Address: 8031 Little Dipper Ave Anchorage . AK 99504 - Date Issued: Apr 16, 2003 Expiration Date: Apr 15, 2004 Parcel ID: 020-281-42 Site Address: 8031 Little Dipper Ave. Lot Size: 43686 SQ. FT. Total Bedrooms: 4 Permit Bedrooms: 4 This permit is for the construction of: ❑✓ Disposal Field ❑✓ Septic Tank ❑ Holding Tank ❑ Privy ❑✓ Private Well ❑ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each Inspection. Provide notification by calling (907) 343-7904 (24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received By Issued By: Date* Date: S7 #43. Parcel I D Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING tda-ani- Permit Number SW Property owner(s) Tony Strupulis Day phone 269-0524 Mailing address (1) 8031 Little Dipper Ave., Anchorage, AK 9_9504 Mailing address (2) Zip Code Legal description (Lot, Block & Sub d) Pntter Heights Block 2, Lot 9 Legal description (Section, Township & Range) Lot Size U S t /o24_____Acre THIS APPLICATION IS FOR: Sewer Only Sewer and Well Sewer Upgrade THIS PROPERTY CONTAINS: Number of Bedrooms 4 ❑ Well Only 0 Water Storage Hot Tub ❑ Jacuzzi Swimming Pool ❑ Water Softening Unit 0 Therapy Pool ❑ I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit Fees: Y SSiD Waiver Fees: Date of Payment: O3 Date of Payment: Receipt Number: D 3 3 S 87 Receipt Number: (Rev. 12/00) WELL & WASTEWATER DISP❑SAL SYSTEM DETAILS/SITE PLAN POTTER HEIGHTS, BLOCK 2, LOT 9 KN D 1 cs DESIGN DETAILS' 4 BDRM X 150 GPD = 600 GPD APPLICATION RATE = 3 GPD/SO.FT. MIN. ABSORPTION AREA = 600 GPD/ (3 GPD/SQ.FT.) = 200 SOFT. 200 SQ.FT. / 5' WIDE = 40' TRENCH USE 1 TRENCH 5' V x 40' L x .5' D. BOTTOM OF TRENCH = 1' ABOVE ORIGINAL GRADE EFFECTIVE DEPTH - 0.5' DRENCO PACKAGE SYSTEM' 1. INSTALL 1500 GAL SEPTIC TANK V/ INTEGRATED ADVANTEX SYSTEM - OR TANK WILL BE SIZED PER ANCHORAGE TANK FOR A 4 BDRM RESIDENCE. 2. INSULATE TANK, EXCEPT BELOW ADVANTEX PADS TO ALLOW HEAT TRANSFER. 3. NO AIR LINE REQUIRED. NOTES' 1. INSULATE IF<4' OF COVER. 2. INSULATE ALL LINES, SYSTEM COMPONENTS, TRENCH AND TANK WITH 2' HD BURIAL FOAM. 3. ADDITIONAL FILL WILL BE ADDED OVER SYSTEM TO ACHIEVE MIN. 3' COVER IF REQUIRED. 4. THE CONTRACTOR SHALL HAVE THE SYSTEM LAYOUT STAKED BY A REGISTERED LAND SURVEYOR PRIOR TO CONSTRUCTION. NO PVxJC VRLS WITHIN tar pf PROPOSED SYSTEM. NO PRIVATE VEILS VITIN Pr Er PROPOSED SYSTEM EXCEPT AS ICED. No SEPTIC SYSTEMS viTNIN ter OF ►REPOSED VELE EXCEPT AS NOTED. THE CONTRACTOR SHALL VERIFY ALL SEPERATION 6 SETBACK REQUIREMENTS PRIOR TO CONSTRUCTION. PREPARED FOR' ANTHONY STRUPULIS 8031 LITTLE DIPPER AVE. ANCHORAGE, AK. 99504 (907) 337-9006 FIELD BOOKS COMM/TEN d'iliostsstolose Scales 1'= 100' PAGE 1 OF 4 ll ED) ENGINEERING 20441 PTARMIGAN BLVD. EAGLE RIVER, AK 99577-8736 (907)898-6111/FAX (907)898-8111 <NDE i) W -P (U WASTEWATER DISPOSAL SYSTEM DETAILS POTTER HEIGHTS, BLOCK 2, LOT 9 0' TH#.2-2 PROPOSE BDRM HO .0 l 2a.1 �Q /los' �� Q j 2Q irP •. ❑P❑SED 1 ' 0 GAL �� S TIC TANK ITH IN EGRATED AD •NTEX I T TR ATMENT SYSTE 56.8' a OF Arts'it" '4s II D 't: tir 3/4E 331Orkte CE -7116 63.4' 48.8' PREPARED FOR! ANTHONY STRUPULIS 8031 LITTLE DIPPER AVE. ANCHORAGE, AK. 99504 (907) 337-9006 Z3 Scale, 1'= 20' PAGE 2 OF 4 FIELD BOOKS W1pV1ED: °01"C'"" LANG VBG STNm,a acaaDt KMD MUNI: DATE: 4/7/03 END ENGINEERING 20441 PTARMIGAN BLVD. EAGLE RIVER, AK 99577-8736 °AP 3639 Mai FILL 02067.DWG 0° "" 02067 (907)896-6111/FAX (907)698-8111 AdvanTex Treatment System AX 20 Series - Mode la a ■ End View PREPARED FOR' ANTHONY STRUPULIS 8031 LITTLE DIPPER AVE. ANCHORAGE, AK. 99504 (907) 337-9006 Scale! NTS PAGE 3 OF 4 FIELD BOOKS Ktif in LANG 0RAM VBG nn ° KMD °"° 4/7/03 ]I ID ENGINEERING 20441 PTARMIGAN BLVD. EAGLE RIVER, AK 99577-8736 MG. fit °R1c' 3639 lap ^`E 02067.DWG alk"' 02067 (907)696-6111/FAX (907)696-8111 WASTEWATER DISPOSAL SYSTEM DETAILS POTTER HEIGHTS, BLOCK 2, LOT 9 4' MONITORING TUBE FR OM ADVANTEX I— --iI//ii/ii/ii/Iii//ii/i///iii//ii/iIi,/»t/,/t/tre/iiii//////ii% O 0 j 4' DISTRIBUTION LINE 6 ;j 4' CLEANOUT 4' MONITORING TUBE 40' PLAN VIEW LEACHFIELD DETAILS 4' MONITORING TUBE 0 -INSULATION —FILTER FABRIC FINAL GRADE AA SLOPE MAX BRACING AS NEEDED PLYWOOD BARRIER AROUND TRENCH r4' CLEANOUT ORIGWAL GRADE REMOVE TOP 1' OF SOIL & ALL ORGANICS ars OFAL,gc� der ‘,140PEss101113' FINAL GRADE 2' MIN COVER 5' WIDE pROFII E VIEW LEACHFIELD DETAILS ORIGINAL GRADE 13-15% 5' SEWER ROCK 2+' MIN M.O.A. APPROVED SAND FILTER NOTE' BOTTOM OF SEWER DRAINROCK MUST BE 4+ FEET ABOVE GROUNDWATER AND 6+ FEET ABOVE BEDROCK. PREPARED FOR: ANTHONY STRUPULIS 8031 LITTLE DIPPER AVE. ANCHORAGE, AK. 99504 (907) 337-9006 Scale' NTS PAGE 4 OF 4 F1CW BOOKS e "iDn't JOHNSON DRAM KMD smmG: JOHNSON G"ccKEo KMD ASflT: JOHNSON am 6/28/02 E ID ENGINEERING 20441 PTARMIGAN BLVD. EAGLE RIVER. AK 99577-8736 DWG. ftL C1atr SE703 Acv ^'L 01081.DWC " "O.: 01081 (907)696-6111/FAX (907)696-8111 IK ID ENGINEERING, INC. 20441 PTARMIGAN BLVD. EAGLE RIVER, AK 99577-8736 Performed for. Project: Depth (Feet) 8 9 r.Wrws B.O.H. 10- 11- 12- 13- 14- 15- 16 17- 18- 19- IiOLE PRESOAKED 20- PRIOR TO TEST fw* i 9I� 6 *10 i e r^1 Kenneth M. Duff. O' �� SOILS PERCOLATION TEST ,�f� 9Fo•..,•,,,,•,.••��a,% 1 �` ROFESSt0�P.�0- Anthony Strupulis Date Performed: 08/2 N�� Potter Heights Block 2, Lot 9 ORG — black loam w/ organics & MIJSM lease <4" GP — firm, brown, gravel w/ sand, trace of silt & occasional cobble to 8" seeps GM — gray/brown, moist, firm, silty gravel w/ cobbles TEST 1-1OLE # 02-1 SEE ATTACHED SITE PLAN FOR HOLE LOCATION Was Ground water encountered? YES Depth to water after monitoring? 3' What depth? 5' Date? 09/03/02 Reading Date Gross Time Net Time Depth to Water Net Drop 1 9/3/02 1:00 - 6" - 2 1:10 10 min 29/16" 37/16" 3• 111 - 6" - 4 1:21 10 min 211/16" 35/16" 5 • 1:22 - 6" - 6 1:32 10 min 214/16" 32/16" 7• 1:33 - 6" - 8 1:43 10 min 214/16" 32/16" 9• 1:44 - 6" - 10 1:54 10 min 215/16" 31/16" 11• 1:55 - 6" - 12 2:05 10 min 215/16" 31/16" • Water Added Percolation Rate 3.27 (min/in) Pere Hole Diameter 6" Test Run Between 1.5 feet and 2.5 feet I, Kenneth M. Duffus, certify that this test was performed in accordance with all State and Municipal guidelines in effect on this date. KNID ENGINEERING, INC. 20441 PTARMIGAN BLVD. EAGLE RIVER, AK 99577-8736 4111 .'44�..OF'I'�00000 •�Gj ,•• ,�•,, •. S.v •� •n •••j Ka• rmen h., v6I • 0/ 4/,-p; CE 7116 _ /S•�a�"/ V e' t-•"OFSSI0v- oss Date Performed: 08/27/02 SOILS PERCOLATION TEST Performed fon Anthony Strupulis Project: Depth (Feet) Potter Heights, Block 2, Lot 9 TEST 110LE # 02-2 Rownia) - 'fit: Org -black loam w/ organics 2.M'.y VE5 _[ s :''' ; ;Gm- med dense, moist, gray o {a .; ,_-a:44,711— silty gravel w/cobbles to 7 v' foil 4 1,779's skC 8- 9- 10- 11- - B.O.II. 12- 13- 14- 15- 16- 17- 18- 19- IIOLE PRESOAKED 20- PRIOR TO TEST GP/SP- mosit gray sandy gravel seeps GM — med dense, moist, gray silty gravel w/cobbles to 2' SEE ATTACHED SITE PLAN FOR HOLE LOCATION Was Ground water encountered? YES Depth to water after monitoring? 3.3' What depth? 7 Date? 9/3/02 Reading Date Gross Time Net Time Depth to Water Net Drop 1 9/3/02 1:00 - 6" - 2 1:30 30 min 39/16" 2 7/16" 3" 1:31 - 6" - 4 2:01 30 min 310/16" 2 6/16" 5• 2:02 - 6" - 6 2:32 30 min 310/16" 2 6/16" " Water Added Percolation Rate 12.61 (min/in Pere Hole Diameter 6" Test Run Between 1.5 feet and 2.5 feet 1, Kenneth M. Duffus, certify that this test was performed in accordance with all State and Municipal guidelines in effect on this date. JKND ENGINEERING, INC. 20441 PTARMIGAN BLVD. EAGLE RIVER, AK 99577-8736 (907) 696-6111/FAX (907) 696-8111 ON-SITE WASTEWATER DISPOSAL SYSTEM CONSTRUCTION PRACTICES AND MATERIAL SPECIFICATIONS LEGAL DESCRIPTION: POTTER HEIGHTS, BLOCK 2, LOT 9 GENERAL: 1. The scope of this project includes the installation of a septic tank and/or drainfield to serve a single-family residence on the referenced property as delineated on the attached Municipality of Anchorage (MOA) permit and site plan. 2. Construction shall be in accordance with the approved site plan and design drawings; MOA permit with any special provisions or conditions, and all applicable State and Municipal Wastewater Disposal Regulations. 3. KND Engineering, Inc (KND) assumes no responsibility of the accuracy of the as -built survey provided by the owner or owner's representative. 4. The owner or contractor is responsible to notify the engineer of any discrepancies noted on the design plans or drawings prior to commencing work. These discrepancies could be, but not limited to, possible encroachments, surface water, varying soils, unplatted easements, types or use of dwellings on or adjacent to property, nearby public wells, etc. 5. The contractor shall be responsible for locating any necessary underground utilities, easements, property lines and surface water. The owner and/or contractor shall ensure, if deemed appropriate, that a registered land surveyor prior to construction flags all setbacks. 6. The contractor shall be responsible for verifying all pertinent separation distances and component layout. 7. Unless specifically agreed otherwise, the property owner shall be responsible for final grading areas subsequently depressed from soil settling. On all leachfield mound systems, the property owner shall be responsible for ensuring a satisfactory vegetation growth over the mounded area. 8. The MOA Development Services Department On -Site Water & Wastewater Program must certify contractors installing wastewater disposal systems. Owners installing their own systems must also receive prior approval from said MOA Department. SEPTIC TANK / HOLDING TANK / LIFT STATION INSTALLATION: 1. A septic tank is to be constructed by a certified septic tank manufacturer. Construction shall include two 4" cleanouts for pumping access. 2. The septic tank shall be sufficiently bedded with proper material and compacting to prevent damaging, settling or shifting of the tank. 3. All standpipes on the septic tank shall extend a minimum of 12 inches above the final grade. 4. Septic tanks installed with less than 4 foot of cover shall be insulated. The contractor will ensure that the fill over the tank does not exceed the burial depth rating. 5. A foundation cleanout shall be installed one to four feet from the building foundation. In the line between the tank and the leachfield there shall be two adjacent cleanouts (unless an effluent pumping system exists within the septic tank). These cleanouts shall be located on undisturbed soil not more than 10 feet from the tank. The second cleanout, in line, shall be to clean toward the septic tank. 6. Final grading over the septic tank shall be such that a positive slope exists away from the septic tank. Page 1 of 3 Reference: Potter fits., B2, 19 Date: 04/08103 Page: 2 of 3 7. All I-I.D.P.E. tanks shall have a vertical length of 4 -inch perforated drainpipe besides the tank extending to the bottom of the tank to above grade to monitor ground water. 8. All tanks shall be anchored when there is not enough adequate soil cover to resist buoyancy forces in high -groundwater areas. 9. All holding tanks and lift stations shall have an audible and visual alarm inside the residence. 10. All lift stations shall be wired in compliance with the Uniform Electrical Code and all MOA guidelines. 11. The contractor shall remove the old tank, or abandon it in compliance with the Uniform Plumbing Code. The contractor is solely responsible for the abandonment procedure. ABSORPTION TRENCH/DRAINFIELD INSTALLATION: 1. Excavate the proposed trench to the dimensions shown on the design. The bottom of the excavation shall be within 2 inches of level. If the sidewalls of the excavaction become smeared, they must be raked or scratched (roughed -up) before gravel (sewer rock) placement. 2. Once the sewer rock is installed, the distribution pipe is installed level with the perforations facing downward. Gravel is then to be placed over the distribution pipe to provide a minimum of 2 inches of cover over the pipe. 3. A silt barrier must be installed between the final gravel layer and the native soil backfill. Ensure the silt barrier covers the entire gravel surface before placing backfill. 4. Monitoring tubes shall be four- (4) inch diameter, installed approximately in the locations shown on the design, and extend a minimum of 12 inches above final grade. The portion of the monitoring tube extending through the gravel shall be perforated from the bottom of the trench to the invert of the distribution pipe. This is equivalent to the effective depth of the gravel as noted on the design. 5. Backfill over the final gravel layer must not be less than twenty-four inches. Insulation must be installed when the backfill depth is less than thirty-six (36) inches. The finish grade over the trench must be mounded to prevent the formation of a depression after settling. 6. All advanced technology waste water disposal systems (Advantex, Biocycle, Intermittent Dosing Sand Filter, etc...) shall be constructed, installed, maintained and monitored per manufacturer's specifications and MOA requirements. MINIMUM MATERIAL SPECIFICATIONS: 1. A MOA approved septic tank manufacturer must construct any septic tank proposed for installation. 2. The following pipe materials are MOA approved for use in septic system installations: Type of Pipe perforated Solid Cast Iron Yes Yes ASTM D3034 (PVC) Yes Yes ASTM F810 (HDPE) Yes No ASTM D2662 (ABS) Yes Yes 3. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Company Styrofoam HI or equal). 4. Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Femco, or equal). 5. A permeable nontoxic silt barrier (Typar 3401, Mirafi 140N, or equal) must be installed between the final leachfield gravel layer and the native soil backfill. 6. All leachfield gravel (sewer rock) shall be 0.5"-2.5" screened gravel with less than 3% passing the #200 sieve. If deemed necessary, a sieve analysis should be performed. 7. When sand is being used as a filter material, its gradation specification must conform to current MOA or DEC requirements. Reference: Potter Hts.,132, L9 Date: 04/08103 Page:3 of 3 INSPECTIONS: Typically there will be three (3) inspections required during the installation of the wastewater disposal system. These inspections will occur as follows: 1. The first inspection must be conducted after the excavation of ditches, pits, trenches, or beds and before the installation of any gravel. A septic tank may be set in place, but may not be backfilled before this inspection. 2. The second inspection must be conducted after the placement of the sewer rock, distribution lines, standpipes, and cleanouts, but before the placement of the silt barrier, insulation, or any other backfill. 3. The final inspection is to occur upon final grading of the property. Often there will be more than these 3 inspections required, especially with the installation of multiple trenches, sand filters, pressurized distribution systems, etc. The inspecting engineer is to be contacted at least 24 hours prior to the start of construction. If necessary, a pre -construction meeting will take place on-site. The inspecting engineer will not coordinate, direct or control in any way the contractor's activities. The owner shall contract with the contractor to perform the work outlined in these specifications and attached plans and in accordance with the attached MOA permit. All materials, components, and construction practices shall comply with the MOA's and the State of Alaska's latest ordinances, regulations, or policies regarding wells and septic systems. The failure of the inspecting engineer to notice a material or construction non-compliance does not relieve the contractor of his/her responsibility to correct such deficiency. There will be no contractual arrangement existing between the contractor and KND Engineering, Inc. KND shall be the owner's representative and will inspect the work as stated above to document the contractor's activities. Final acceptance of the contractor's work rests with the owner and the MOA. KND shall have no liability to the owner or to others for acts or omissions of the contractor or any other persons performing work on this project or the failure of the contractor to carry out the work in accordance with these construction documents. KND's inspecting engineer will not be responsible for the construction means, methods, and techniques, sequence, procedures or the safety precautions incident to this project. BY PROCEEDING FORWARD WITH THE INSTALLATION OF THE WATER AND/OR WASTEWATER SYSTEM (S), THE PROPERTY OWNER, CONTRACTOR, AND WELL DRILLER ACKNOWLEDGES HAVING READ AND ACCEPTED THESE SPECIFICATIONS. Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 ON-SITE SEWER/WELL SUBMITTAL COMMENT SHEET To: Brent Western Legal description: Potter Heights Block 2 Lot 9 The attached paperwork has been reviewed and is being returned for the following reasons: ❑ Original signature or stamp missing on ® Calculation error in design. Need to show proper vertical separation distance from bottom of mound system to ground water on design cross-section ❑ Additional soils information needed. ❑ Water monitoring results inadequate. ❑ Discrepancy in information submitted. ❑ Topographic information missing or inadequate. ❑ Incomplete; missing ❑ Incomplete; missing _ ❑ Additional adequacy test information needed. _ ❑ Water sample unacceptable. ❑ Measured/proposed distances/dimensions missing. O Locations of all soils, percolation and water monitoring tests not shown. ❑ Proposed system too deep for soils information submitted. ❑ Well log required. _ ❑ Omission in narrative. _ ❑ Insufficient fill over tank or field._ ® Other. Until the septic system design is corrected the permit is not valid. Name of reviewer: Joe aoodall Date: 5114103 Please supply the necessary information and re -submit your request. LEAVE THIS FORM ATTACHED TO THE PAPERWORK l,ti+ve:-iFI•vtri 1+ . Z i Jn,'r* re—7 ,4AIt 71i s Qt >'tE Cerii el (;z,v); f 60 No 1 /--/i.1/2O Gui fo j-E4v; ots,va p;fg . Cop, -Es (wily RE Pe'2ri.f/cJ.1 '3c -i- Ol2iG i`a'R Argo TO PeIl,eiW /&' &v.si)-c Fi/c , PfEASE r �L jrTo;{ Avy yzsr DV,. M -W Drilling, Inc. •P.O. Box 110378• Anchorage, AK 99511♦ •907-345-4000 • 907-345-3287 Fax* Job No.: 03-181 Project No.: N/A Permit No. SW030084 Groundwater Wel! As -Built & Loj • Well Owner: Anthony & Diane Strupulis • Use of We!!: Domcstic • Legal Description: Potter Heights Subdivision, Block 2, Lot 9 19030 Potter Circle- Anchorage, Alaska Constntction • hole Depth: 120' • Casing Size: 6" • Cased To: 118.86' • Drill Method: Air Rotary *Material: A 53 Steel Perf. • Well Completion- Open end X Screen _ Perforated _ Method: *Screen/ Perforation description: Nonc *Grout Notes: (1) Sack- No. 8 bentonite granules • Notes: • Well Development: Method: Air surge Notes: *Static water leve! (S1VL) 86' (above) (below) top (leasing (TOC). • Well yield test at 10 gallons per minute (GPM)/gallons pev-hoar (GPII) for 1 hours with 100% of drawdown (DD) from static level (SWL). •Method: Air lift • Date of completion: 15 September 2003 • Pump Install: 0 Depth in feet from top of casing. Details of formations penetrated, sire of material, color and hardness. 0 TO 3 Casing stickup 3 TO 20 Boulder gravel 20 TO 42 Gravel: clayey 42 TO 98 Clay: gravelly 98 TO 108 Gravel: clayey, wet 108 TO 120 Water bearing gravel TO TO TO TO TO TO TO TO NWWA—Ceruified_Cantraclot• Certificate No's. 814 & 973 TO - PERFORMED FOR: L� vr�l"O` 0i-tiL4eG ENVIRO ENT,iL I..:Or CTIoN MUNICIPALITY OF ANCHORAGE MaYERcrION DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION 825 L. Street, Anchorage, Alaska 99501 264-4720 SOILS LOG — PERCOLATION TEST /41 /.ee LEGAL DESCRIPTION: L 0 ! / ig` e 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 MCV+�'1 1 r 1`RF�efii'- �tN°tip., v► COMMENTS �STT RECEIVED DATE PERFORMED: Ateli/s c'6d SLOPE WAS GROUND WATER ENCOUNTERED? IF YES, AT WHAT DEPTH? S L 0 P E SITE PLAN Reading Date Gross Time Net Time Depth to Water Net Drop PERCOLATION RATE (minutes/inch) TEST RUN BETWEEN FT AND FT PERFORMED BY: h 4‘61 72-008 (6/79) CERTIFIED BY: DATE: 7 �!