Loading...
HomeMy WebLinkAboutPREUSS #1 BLK 1 LT 3 REM ; Municipality of Anchorage Page of DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box :196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744 On-Site Wastewater Disposal System and/or Well Inspection Report Permit Number; ~UJ 970 )~'~' PID Number: (:~'O- Name: ~1~ ~. A~ Wastewater System: D New ~ Upgrade Address: ~o~ ~ ~,~o~ ABSORPTION FIELD Ph~: JNo. of B~r~ms:'. ~D~pTrench D Shallow Trench ~B~ DUound DOther Block: ~ ~ Su~iv~ion: ~pth to pl~ ~fl~ f~ ~1 g~de: Grovel depth ~ath pl~ Township~ I Range:~ ~ I S~tion~ Fill add~ a~ve original grade: ' Gravel length: ' ~ New ~ ~ Gmvelwidth: Num~[ of lines: Upgrad~// WELL: Cl~[fi~tion (Prlwte, A,B,C): I To~ Cas~ To: To~I abso~flon a~a: Dfllle~ ~ IDa~eO,,~: StatgWaterLe~: Ins~lle~ , Dateinstall~: SEPARATION DISTANCES ~Sep~i~ ~ Holding ~ S.T.E.P. From Ta~k Field S~tion Tank ~r Mnes ~~ Well- I0~ ]b~ '~1 + ) ~, Matedal:~ ~ Number of C~pa~ments: Sudace , LineL°t ~ I ~ ~ 4~ ~ +}O~ Size in gallons:I~ Manufa~ure~ Foundation II ~ ~ ~ + "Pump." ,eyelet: ~~e, a~ I High water alarm at: Cu~ain Drain +~ ~ +~' ~1~d"l I~"ct'°ns pO~°~ by: Remarks: ~y~ ,~L~ ~'>~~ BENCH MARK Lo~tion and ~cd~on: J ~sum~ Elevation: ~ - * ENGINEER'S SEAL Reviewed and approved 72-013 (Rev. 9/91) MOA 25 PERMIT. # SW930157 PAGE 2 OF MUNCIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH ~: HUMAN SERVICES ENVIRONMENTAL SERVICES SECTION 0N--SITE WASTEWATER DISPOSAL SYSTEM INSPECTION REPORT LEGAL BESCRIPTION: LOT 3 BLOCK 1 PRUE-~S SUB. ADD #1 PID 050--571--07 lo, u'r~. ~ 134,30 A'RSDRPTInH TRENCH ~,SIS nF ELEV! 59,~'~--~?.6.%125n G ~EPTIC ~ 100' WELL R~DIU{ ~,/ELL 134,30 / EAGLE RIVER RI] PAGE 1 OF MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND HUMAN SERVICES P.O. BOX 196650, 825 "L" STREET, ROOM 502 ANCHORAGE, ALASKA 99519-6650 ON-SITE WASTEWATER DISPOSAL SYSTEM (UPGRADE) PERMIT PERMIT NUMBER:$W930157 DESIGN ENGINEER:CONSTRUCTING ENGINEERS, INC. OWNER NAME:ARNDT GISELA C OWNER ADDRESS:20109 EAGLE RIVER RD EAGLE RIVER AK 99577 PARCEL ID:05057107 LEGAL DESCRIPTION: PREUSS #1 BLK 1 LT 3 DATE ISSUED: 6/16/93 EXPIRATION DATE: 6/16/94 REM LOT SIZE: 25838 (SQ. FT.) NUMBER OF BEDROOMS: 4 THIS PERMIT: 4 THIS PERMIT IS FOR THE CONTRUCTION OF: DISPOSAL FIELD /SEPTIC TANK SYSTEM ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH: 1. THE ATTACHED APPROVED DESIGN. 2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS 15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80). 3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY CALLING 343-4329 OR 343-4681 AFTER BUSINESS HOURS 4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING WEATHER MUST BE EITHER: A. OPENED AND CLOSED ON THE SAME DAY B. COVERED, SEALED AND HEATED TO PREVENT FREEZING 5. THE FOLLOWING SPECIAL PROVISIONS. SPECIAL PROVISIONS: TRENCH WILL BE CONSTRUCTED NO DEEPER THAN 8 FT. BELOW EXISTING GRADE. TRENCH W~ILL BE MINIMUM 42 FT. RECEIVED BY' DATE: HENRY WILSON g601 BUDDY W£RN£R DR.: ANCHORAGE, AK 99516 (907) 346-2000 Constructing Engineers Engineers, Surveyors CHARLES A. LANDERS HC83 BOX 192PA, MYRTLE DR. EAGLE RIVER, AK 99577 (907) 694-9098 June 14, 1993 Municipality of Anchorage On-Site Services Division PO Box 196650 Anchorage, AK, 99519 Attn: John Smith, P.E. re: Submittal for Septic Permit, L3 Bi Pruess, Add #1 Gentlemen: Attached are plans for a new wastewater absorption system for the subject lot. The owners/occupants of the house are unable to use the plumbing system in the house at this time since the system will not accept any effluent without either backing up into the house or flowing over the field cleanout. Simply put, the existing septic system has failed. We are asking for expedited review and issuance of the permit in order to alleviate the system failure. If you have any questions, please contact me at 694-9098. Respectfully submitted, Chuck Landers Constructing Engineers SITE PLAN-WASTEWATERABSORPTION SYSTEM SITE PLAN DETAILS PROPOSED REPLACEMENT WASTEWATER ABSORPTION SYSTE! LOT 3 BLOCK I PREUSS SUBDIVISION, ADD #1 PREPARED FOR: MR. JESSE JAMES Zolo9 EAGLE RIVER RD EAGLE RIVER, AK, 99577 SCALE: 1" = 30~ D~WN BY CAL CONSTRUCTING ENGINEERS346-2000 9601 BUDDY WERNER DR 694-9098 ANCHORAGE, AK, 99516 6-6-93 D~WXNG # 93-SI-06-4 SITE PLAN-WASTEWATER ABSORPTION SYSTEM :.,,/ 1[-.,,. J I I SITE PLAN DETAILS PROPOSED REPLACEMENT WASTEWATERABSORPTION SYST~ LOT 3 BLOCK I PREUSS SUBDIVISION, ADD #1 .PREPARED FOR: MR. JESSE JAMES 20109 EAGLE RIVER RD EAGLE RIVER, AK, 99577 SCALE: 1" = 1~' D~WN BY CAL CONSTRUCTING ENGINEERS3&6-2000 9601 BUDDY WERNER DR 694-9098 ANCHORAGE, AK, 99516 6-6-93 D~WING # 93-52-06-4 CONSTRUCTION NOTES: ~. 2H HD IN~ULA¥~ON R~QUIRED OVER All DO~YJON~ OF ~ROUND COVER. ~, CON¥~A&TOR MAY IMPORT gov~ TO H~RY NINIHUH 4~ GROUND COVER OVB~ ~YST~M. ~, S~PtI¢ TANK R~QUIRB~ ~" ~NSULAT~ON. ~OOP~ OF PROJ~OT.~ New p~oposed absorption field is oe~gned for a four (d) bedroom ~y~ten%. Lot i~ ~erved by a private well. d ' - Soils rat~l~, - 600 gpd proposed additiol%, 1,2 gpd/flf (trench dsflign) Hi~imum ~zJ. ng; 600 ~d ~ 1.2 gpd/sf ~ 500 sf ~b~orption 500 ~f ~ (~)(~'D) = 36' minimum t~'~!uh l~ngth IMPAC~ ON ADJAOD~ LO~S: There a~e no private wells wi%bin ~00, of this pz'opoaud c~b~c~rptjcm sy~t.~'~m, mh~r~ ara m-~ D,hli~-: wall~ wlt.hin 200' of ~-opo~ed replacement system, The proposed ab&:orption system has no adverse · mpact upon any adjacent lot~ as M~own on attached site diagram.  20i09 ~A~L~ RZV~R ROAD '~% ~W~.~ !,~ ~A~L~ RIVER, AK, 99577 ~ ~% ~- .,"~ DRANN ~Y PHONE He,, : 9717 ~94 . ~.-T.-~L-~, :][.-'"; 19_q3 5: EI2Pi"I PE14 Municipality of Anchorage OEPARTMENT OF ItEALTIt & I ILIMAN 8FRVIOFG 825 %" 8froot, Anchor,,ge, Alaska 1~0502-0650 SOILS LOG --. PERCOLATION TEST t"ER FORMED FOR~ 17 18 '19 2O OOMMEN'I ~ Townehip, Ran§e, Seotion: ,~LQPE L IF YES, AT WHAT ~1 t Readin9 Dele ~ro¢~ Net Oepth to 1 / TIll, / Time 'ILSI ItUN ULI WLLN :) ANCHORAGE AREA eo. Department of Environmental Quality 3330 C Street ' Anchorage, Alaska 99503 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM NAME Robert Fitz~patrick MAILING ADDRESS Gen_____~el Ea~gle River PHONE LOCATION LEGAL DESCRIPTION Lot 3cBlk 1, Preuss Sub SEPTIC TANK: UL# 185162 DISTANCE ]02' Stack Steel FROM WELL_ MANUFACTURER MATERIAL INSIDE LENGTH INSIDE WIDTH -- LIQUID DEPTH Steel NUMBER OF 2 COMPARTMENTS. _LIQUID CAPAC iTY_]_2_~]~ G A L LO NS. SEEPAGE PIT: NUMBER OF PITS. l LINING MATERIAL. 10,~ DIAMETER_ 80OR WIDTH 22,' LENGTH. ]8' 8' , DEPTH CRIB SIZE: DIAMETER_ 8'DEPTH__61 DISTANCE FROM: WELL 125~ TOTAL EFFECTIVE BUILDING FOUNDATION NEAREST LOT LINE. ABSORPTION AREA {WALL AREA) SQ. FT. ADDITIONAL ABSORPTION WELL: TYPE Dri 11 ed -CONSTRUCTION Standard DEPTH DISTANCE FROM: BUILDING NEAREST NEAREST SEPTIC SEEPAGE FOUNDATION __ , LOT LINE__ SEWER LINE_ TANK SYSTEM CESSPOOL OTHER SOURCES APPROVED · DISAPPROVED - REMARKS_ DISTANCES: INSTALLED BY: Frontier Excavating PIPE MATERIAl - Cast Iron LOT SLOPE: REMARKS: _ Form No. EQ-031 DIAGRAM OF SYSTEM DATE _8/] 6/74 APPROV~~ /G.A.A.B. R&M ENGINEERING & GEOLOGICAL CONSULTANTS 229 EAST 51st. AVE. - P.O. BOX 6087 - ANCHORAGE, ALASKA 99503 TELEPHONE 907--279-0483 TELEX 090-3541g Civil Engineers Geologists /and Surveyo, JAMES W. ROONEYo P. E. MALCOLM A. MENZIES, P.E.. L.S. JAMES H. WELLMAN, P.E. RALPH FI. MIGLIACClO Engineering Geologist August 21, 1974 R & M No. 462066 Mr. Don Zimmerman P.O. Box 596 Eagle River, Alaska Re: Test Hole and Soil Log'Report for Sanitary System Lot 3 Block 1 Pruess Subdivision Dear Mr. Z~mmerman. We are submitting herewith the test boring results and our comments regarding soil conditions encountered at the subject site. This investigation was performed in accordance with your request of August 15, 1974, and those procedures outlined in a letter dated September 13, 1971 by Mr. Rolf Strickland of the Greater Anchorage Area Borough Department of Environmental Quality. A single test hole was put do~n within the Lot 3 area for the purpose of defining general subsurface soil conditions for the proposed sanitary system. Excavation was accomplished with a tractor-mounted backhoe and the test was extended to a total, depth of 16.0 feet below ground surface. The final log prepared for the test hole has been included in Drawing A-0I. Ground water Vas not encountered in the test hole. We appreciate being given this opportunity to be of service .to you. Should you have any questions with regard to the above, please do not hesitate to contact us. Very truly yours, R & M ENGINEERING &!GEOLOGICAL ~James~W. Roon e~/~' ~ CONSULTANTS, INC. .jWR:kd xc: GAAB TH-1 8-26-74 SANDy S!LT W/SOME ORGAN!CS (ML) · 0.5~ GRAVELLy SAND W/SOME SILT (SP) 2.$e SANDY GRAVEL W/TRACE. S!LT (GW) GRAVELLY SANb W/TRACE S!LT (SP) 8.5' SAND (SP) 10.5' SAND W/TR - AC~ SOME SILT (SM) I6~O' T.D. 'NO'WATER TABLE NOTE; Test hole excaymted with tractor-mounted backhoe. R Engineering E~ Geological Consultants Inc. ANCHORAGE FAIRBANKS ALASKA JUN£AU MR. DON ZIMMERMAN PROPERTy P.O. BOX 596 EAGLE RIVER, ALAKSA APPLIC ' IT FILLS OUT UPPER HAL ONLY Property Owner~t~ ' ~' ~ ' ,. ,,{.,/f-'~ Phone Buyer Address . ': Zip Code ,~ ;'~ ~L ~; ' ,, Lending Institution Phone Address Zip Code Realty Co. & A~nt Phone Add.ress Zip Code Legal Description Type of Resi~nce ~gle Family ~ Multiple Family No. of Bedroo~ ~ giber Water Supply ~dividual A~ACH WELL LOG. A w~l log is required for all wel~s drilled since June 1975. ~ Community For wells drilied prior to that date, give well depth (attach log if available). ~ Public Utility Sewer Disposal ~ndividual Year Individual Installed: "~ Public Utility When Connected to Public Utility: ~ Holding Tank NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH RE~EST BEFORE ~OCESSlNG CAN BE INITIATED. Time Time Time Time Date Date Date Date/ Inspector inspector Inspector Inspector Field Notes: JUN 2 ~ "Dapt. of t-teo, lth & (~ ) APPROVED BEDROOMS 'COND T ONe OF APPROVA~flVd 0Jl~]~.~; ( ) DISAPPROVED ( ) CONDITIONAL APPROVAL* Soils Rating Date ~wer Installed Well To Absorption Area Well Log Received ~'-~ ~l~ff Well ,o Tank Septic T~k Size 72-023 (3182) E~(CAVATION ROBERT A. SHAFER CIVIL ENGINEER WORK 694-2979 July 10, 1983 Gisela Arndt 1432 Eagle River Road Eagle River, Alaska 99577 Dear Ms. Arndt, Reference: Lot 3: Block 1: pruess Subdivision ~1 A sewer system adequacy test was performed on the system located on the referenced property as you requested.. The septic tank was pumped and verified to have a capacity of 1000 gallons. The seepage pit was tested by charging the system with 1000 gallons of fresh water and after a period of 24 hours approximately 584 gallons had percolated ~out of the crib. It can be concluded from this test that the waste water disposal system serving ~he three bedroom residence located on this property is currently functioning adequately. However, the~ system cannot be guaranteed against subsequent failure. It should also be noted that the wires and the sanitary seal on the well have been brought up to code. If we may be of further service, please do not hesitate to contact R /ss , cc: Municipality of Anchorage Department of Health and Environmental Protection SRB 196X EAGLE RIVER, ALASKA Eagle River Area GREATER ANCHORAGE ARE H · .% Department of Environmental Quality /. ~ (0 ,.~3330 "C" Street, Anchorage, Alaska 99503 274-4561 ~/~. ~ ~1' ~ ~ Date Received March 9, 1977 5'~0'e2pN[' ~ Tim ' [,~ ~ e of Inspection ~.'~ ~/ ' ~ Date of Inspection ~-~ ~}~ / INDIVIDUAL SEWER & WATER FACILITIES Conv. Approval requested by: Security Pacific Mortgage Mailing Address: 1101 East Tudor Road Phone: 2. Property Owner: Don Davis Phone: 4. 5. 6. Mailing Address: % Jo Davis 276-7777 Legal Description: Lot 3 Block 1 Preuss Location: Eagle River Road ~,~/N3_~ Type of facility to be inspected Single Family No. of bedrooms 3 Well Data: A. Type Individual B. Depth C. Construction D. Bacterial Analysis' 7. Sewage Disposal System: On-site system __ ~_~ A. Installed C. Septic Tank: D. Seepage Pit: E. Disposal Field: Distances: 1974 B. Installer 1. Size /~5~ 2. Manufacturer ~F-~' 1. Absorption Area 2. Material Total length of lines A. Well to: Septic tank /(PP~ , Absorption area /~_~,~, Sewer Lines Nearest lot line , Other contamination B. Foundation to septic tank , Absorption area Absorption area to nearest lot line EQ-034 (1/74) Page 1 of two pages Pag~ 2 6f two pages - Rt est for Approval o7 Individual, ~er & Water Facilities Legal Description Lot 3 Block 1 Preuss Subdivision Comments Approve~L~ Disapproved Date~ _ Approva'~>~¢lid for one year from date signed Greater Anchorage Area-Borough, Department of Environmental Quality DIAGRAM OF SYSTEM ! certify that the information contained in this request for approval to be a true and accurate representation of the subject sewer and water facilities and these facilities are operating satisfactorily. SIGNED Date , EQ-034 (1/74) Will be picF=4 up - call Jo Davis Z/O-1/I1 rot lnzorma~lon '~' ~UNICIPALIT( OF ANC~IOP~,~ MUNICIPALITY OF ANCHORAGE DEPt. O~ DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTIONENV~RONMENL% 2510 East Tudor Road, Anchorage, Alaska 99504 276-2221 MAR - 19Y7 REQUEST FOR APPROVAL OF INDIVIDUAL SEWER and WATER FACILITIES 1. Type of Inspection: CMRO VA .FHA CONV X~C(XX Don Davis 2. Property Owner: Mailing Address: C/o F~ecUtive Realty Gisela A~ndt Name of Buyer: Day Phone: Mailing Address: 4. Name of Lending Institution: Mailing Address: 5. Name of Realtor or Agent: Mailing Address: 6. Legal Description: Day Phone: Security Pacific Mortgage Phone: Jo Davis ? ExecUtive Realty Inc. 2810 C Street Phone: 276-7777 Lot 3 Block 1 Pruess Subdivision Eagle River (Mile 2.7) Eagle Riv. Rd. Location: Type of Facility to be Inspected: Water Supply Type of Supply: Public Utility If Individual, number of dwellings presently served No. Bdrms. 3 If Individual, depth of well. Sewage Disposal System Type of System: If Individual, date of installation Public Utility. Aprox, 1974 ,Individual X X X SFR Individual (on-site) 72-003(3/76) 1. Approval requested by: Mailing Address: 2. Proper~y Owner: -GREATER ANCHORAGE AREA BOROUGH Department of Environmental Quality 3330 "C" Street, Anchorage, Alaska 99503 274-4561 2/19/75 Date Received Time of Inspection Date of Inspection REQUEST FOR APPROVAL OF INDIVIDUAL SEWER & WATER FACILITIES FOR 2/20/75 e VA Don Zimmerman Eagle River AK Same Phone: Phone: Mailing Address: Legal Description: Lot 3, Block l, Pruess Subdivision Location: East of Intersection of E.R. Lane and E.R. Road 5. Type of facility to be inspected 6. Well Data: A. Type Drilled C. Construction Standard Sewage Disposal System: A. Installed 8/16/74 C. Septic Tank: D. Seepage Pit: E. Disposal Field: Total length of lines Single Family No. of bedrooms 3 B. Depth D. Bacterial Analysis 1. Size 1. Absorption Area 640 sq/ft Sati sfaci:ory Distances: A. Well to: Septic tank Nearest lot line B. Foundation to septic tank B. Installer Frontier Excavating 1250 gals 2. Manufacturer Stack Steel 2. Material 100' , Absorption area , Other contamination 12' , Absorption area 125' , Sewer Lines 23' C. Absorption area to nearest lot line EQ-034 (]/74) Page 1 of two 5;;r.:~:: Legal Description Lot 3, Block l, Pruess Subdivision Comments Approval~.Valid for one year from date signed Greater Anchorage Area Borough, Department of Environmental Quality DIAGRAM OF SYSTEM certify that the information contained in this request for approval to be a true aha accurate representation of the subject sewer and water facilities and these facilities are operating satisfactorily. SIGNED Date EQ-034 (1/74). V~t~a~ ~iuistrati~ 429 ~. Street ?m~chora~e~ 99501 Subject: Lot S, Block l P~$S Sub~ivisia{. 100 feet from ~e s~r ~s~a, sh~d p~de a pottle sU~ply of water if i~mta!l~d to state ad 1~1 specificati~s. John iL Le~, l~.a Eaalo Ri~r District Sanitari~ ORb/st