Loading...
HomeMy WebLinkAboutPREUSS #1 BLK 1 LT 6 REMPreuss #1 Block 1 Lot 6 #050-571-04 Municipality of Anchorage Page / of 2 - DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 • Anchorage, Alaska 99519-6650 • Telephone: 343-4744 On -Site Wastewater Disposal System and/or Well Inspection Report Permit Number: S1J94o/y3 PID Number; 4Sa5?iay Name: i` Wastewater System: ❑ New %Upgrade <�ffGE�J6 L / Address: Z02?3 CrJGLG 21 E '2a.410. ABSORPTION FIELD 96-77 No. of Bedrooms: y ❑ Deep Trench ❑ Shallow Trench ❑ Bed ❑ Mo ❑Other LEGAL DESCRIPTION Soil Rating: Total Depth original grade: GPD/Sq. Ft. Lot: Block: £ division: Depth to pipe bottom from original grade: avel depth beneath pipe � t. Ft. Township: Range: Section: Fill added above original gr Gravel length: Ft. Ft. WELL: El New ❑ Upgrade ' Gravel width: Number of lines: Distancabetween lines: Ft. Ft. Classification (Private, A,B,C): G'xiS 71/ Total Depth: Cased To: Total sorption area: Pipe material: Ft. Ft. SQ. Ft. IqS7,* /�.303G PVG Driller: Date Drilled: Static Water Level: Installer: Ca Date installed: Ft. arty i-orz,� usr: S 26 9y Yield: Pump Set at: Casing Height Above Ground: TANK GPM Ft. Ft. SEPARATION DISTANCES 0septic ❑ Holding ❑ S.T.E.P. To Septic Absorption Lift Holding Public/Private Manufacturer: Capacity in gallons: From Tank Field Station Tank Sewer Lines , / z 6-v Material: Number of Compartments: WeIN //v' /DO — —'-' 25 a- STeEz__ 2_ SurfacWater ' — — — LIFT STATION foo .00' LotSize 'f- in gallons: Man urer: Line ZS / /O — — "Pump on" level at: "Pump off" leve High water alarm at: Foundation �d / S "t" `"— Curtain KNoWj L-- Pump Make & Model Electrical Inspections performed by: Drain BENCH MARK Remarks: Location and Description: %or' oma' riav WALL Assumed Elevation: /po. vv Ft ENGINEER'S SEAL 17034 Eagle River Loop Road, No. 204 Inspections performed by: Eagle River, Alaska 99577 Dates: 1 st r z6 2nd 612- 6 9 41G. - ": ql A Department of Heal and Hu n Services app, / Reviewed and approved by:� Date: - 72-073 (Rev. 9/97) MOA 25 Permit No.. SW940143 Page 2 of 2 Municipality of Anchorage DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 • Anchorage, Alaska 99519-6650 • Telephone: 343-4744 On -Site Wastewater Disposal System and/or Well Inspection Report Legal Description: PREUSS SUBDIVISION ADD.##1, BLOCKI, LOT 6 PID No.:05057104 SCALE 1' _ 72-013 A (2/91) MOA 25 —NEW 1250 GAL. SEPTIC TANK i ENGly.Es 'S SEAL � t �`r c•, � ire 9C- Oe. A. .�.rt-a...,. 'tet z PAGE 1 OF 1 MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND HUMAN SERVICES P.O. BOX 196650, 825 "L" STREET, ROOM 502 ANCHORAGE, ALASKA 99519-6650 ON-SITE WASTEWATER DISPOSAL SYSTEM (UPGRADE) PERMIT PERMIT NUMBER:SW940143 DESIGN ENGINEER:S & S ENGINEERING OWNER NAME:WHITEHEAD RICHARD G & DALENE L OWNER ADDRESS:20233 EAGLE RIVER RD EAGLE RIVER, AK 99577 PARCEL ID:05057104 LEGAL DESCRIPTION: PREUSS #1 BLK 1 LT LOT SIZE: 23838 (SQ. FT.) NUMBER OF BEDROOMS: 4 THIS PERMIT: 4 6 REM THIS PERMIT IS FOR THE CONTRUCTION OF: SEPTIC TANK SYSTEM ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH: DATE ISSUED: 5/24/94 EXPIRATION DATE: 5/24/95 1. THE ATTACHED APPROVED DESIGN. 2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS 15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80). 3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY CALLING 343-4744 (24 HOURS) . 4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING WEATHER MUST BE EITHER: A. OPENED AND CLOSED ON THE SAME DAY B. COVERED, SEALED AND HEATED TO PREVENT FREEZING 5. THE FOLLOWING SPECIAL PROVISIONS. SPECIAL PROVISIONS: RECEIVED BY: ISSUED BY: J-, w , DATE• DATE : '5 Z May 24, 1994 ROBERT SHAFER, P.E. ROGER SHAFER, P.E. CIVIL ENGINEERS (907) 694-2979 FAX 694-1211 HEALTHAUTHORITY APPROVALS Municipality of Anchorage DEPARTMENT OF HEALTH AND HUMAN SERVICES 825 'L' Street SEWER &WATER P.O. BOX 196650 MAIN EXTENSIONS Anchorage, Alaska 99519-6650 SEWER&WATER REFERENCE: Preuss Subdivision #1; Lot 6; Block 1 INSPECTION ENGINEERING STUDIES Request you expedite issuance of a permit to replace the septic system ANDREPORTS serving the four bedroom house on the referenced property. THE EXISTING 1250 GALLON SEPTIC TANK HAS COLLAPSED AND SEWAGE IS SPILLING ONTO THE PROPERTY. WELL INSPECTION Because of the unsanitary conditions and safety hazards, we would &FLOW TEST appreciate you expediting a permit to replace the existing septic tank. If you have questions, or require additional information for your review, ase c ntact us. SITE PLANS i Si erely, ROAD DESIGN K. Shafer, P.E. SOILTEST PERCOLATION TEST STRUCTURAL& MECHANICAL INSPECTIONS ONSITE WASTEWATER DISPOSAL SYSTEM DESIGN jk 17034 NORTH EAGLE RIVER LOOP • SUITE 204 • EAGLE RIVER, ALASKA 99577 " 30' SCALE' Opo a '0 c oeym.. m ror�`tiM A tb LO oy4y mora 9 tj L�rJ Heb t�7 y W 'x CZ m m z9�`-3 D D xraz yzx z ..d o D 0 m N (n 0C z 100' WELL RADIUS II Iz �O C) x [ v z o r r x, D �5Zb O (A D -3 Ln DRIVE / 4 O II O / / (1 n m o / II t i O 0 W o r., I (0 o I P cn x i 0 mro n r �w �I �co g o00 Z-I �CoO �pZ: x� D 4� F- O m Yr xp��r z DDp-r " D��5r,r qp� _ ON-SITE WASTEWATER DISPOSAL SYSTEM CONSTRUCTION PRACTICES and MATERIAL SPECIFICATIONS REFERENCE: Preuss Subdivision #1; Lot 6; Block 1 GENERAL: 1. The scope of this project includes the installation of a 1250 gallon septic tank to serve the four bedroom residence located on the referenced property. The existing 1250 gallon septic tank is to be excavated, pumped, crushed, and removed. 2. Construction shall be in accordance with the approved site plan and design drawings, Municipal permit with any special provisions or conditions, and all applicable State and Municipal Wastewater Disposal Regulations. 3. The contractor shall be responsible for obtaining any necessary underground utility locates. 4. Unless specifically agreed otherwise, the property owner shall be responsible for final grading areas subsequently depressed from soil settling. 5. Contractors installing wastewater disposal systems must be certified by the Municipal Health Department for system installations. Owners installing their own systems must also receive prior approval from the Municipal Health Department. SEPTIC TANK INSTALLATION: 1. A septic tank is to be constructed by a certified septic tank manufacturer. Construction shall include two 4" cleanouts for pumping access. 2. The septic tank shall be sufficiently bedded to prevent settling or shifting of the tank. 3. All standpipes on the septic tank shall extend a minimum of 12 inches above final grade. 4. Septic tanks installed with less than 4' of cover shall be insulated. Page Two Preuss Subdivision #1; Lot 6; Block 1 May 24, 1994 5. A foundation cleanout shall be installed one to four feet from the building foundation. In the line between the tank and the leachfield there shall be two adjacent cleanouts (unless an effluent pumping system exists within the septic tank). These cleanouts shall be located on undisturbed soil not more than 10 ft. from the tank. The first cleanout, in line, shall be to clean toward the leachfield. The second cleanout shall be to clean toward the septic tank. 6. Final grading over the septic tank shall be such that a positive slope exists away from the septic tank. @9Ij1 MUM MATERIAL 1. Any septic tank proposed for installation must be constructed by a Municipally approved septic tank manufacturer. 2. The following pipe materials are approved for use in septic system installations in the Municipality of Anchorage: Type of Pipe Perforated Solid Cast Iron Yes Yes ASTM D3034 (PVC) Yes Yes ASTM F810 (HDPE) Yes No ASTM D2662 (ABS) Yes Yes Use of a type of pipe other than listed above must be approved by the inspecting engineer. 3. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Company Styrofoam HI or equal). 4. Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Fernco, or equal). 5. A permeable nontoxic silt barrier (Typar 3401, Mirafi 140/N, or equal) must be installed between the final leachfield gravel layer and the native soil backfill. 6. All leachfield gravel (sewer rock) shall be 0.5"-2.5" screened gravel with less than 3% passing the #200 sieve. 7. When sand is being used as a filter material, its gradation specifications must conform to current M.O.A. or D.E.C. requirements. Page Three Preuss Subdivision May 24, 1994 INSPECTIONS: #1; Lot 6; Block 1 Typically there will be a minimum of three (3) inspections required during the installation of the wastewater disposal system. These inspections will occur as follows: 1. The first inspection must be conducted after the tank has been set; lines, cleanouts, standpipes, and insulation are in place and prior to backfilling. 2. The final inspection is to occur upon final grading of the property. Often there will be more than these 3 inspections required, especially with the installation of multiple trenches, sand filters, pressurized distribution systems, etc. Thus, the inspecting engineer is to be contacted at least 24 hours prior to the start of construction. If necessary, a pre -construction meeting will take place on-site. The inspecting engineer will not coordinate, direct or control in any way the contractor's activities. The owner shall contract with the contractor to perform the work outlined in these specifications and plans and in accordance with the attached M.O.A. permit. There will be no contractual arrangement existing between the contractor and S & S Engineering. S & S Engineering shall be the owner's representative and will inspect the work as stated above to document the contractor's activities. Final acceptance of the contractor's work rests with the owner and the M.O.A. S & S Engineering shall have no liability to the owner or to others for acts or omissions of the contractor or any other persons performing work on this project or the failure of the contractor to carry out the work in accordance with these construction documents. S & S Engineering's inspecting engineer will not be responsible for the construction means, methods, techniques, sequence, procedures or the safety precautions incident to this project. CONTRACTOR/INSTALLER MUNICIPALITY OF ANCHORAGE JJ DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION ENVIRONMENTAL ENGINEERING DIVISION 825 L Street - Anchorage, Alaska 99501 Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT J _....._' NAME. '- �E� E ❑ ,.NEW UPGRADE MAILING ADDRESS i LEGAL DESCRIPTION L LOCATION�< ^� ray ...._...._..-•.._......_..-�_ ...____._.---._._.___._ /� G:11 ,eetl M, . OF BEDRO MS Well Absorption area Dwelling PERMIT.N . DISTANCE T0: Uy a Z Manufacturer �j j� Material No. of compartments w a y� Liq. capacity in gallons IF HOMEMADE: Inside length Width Liquid depth 6 y DISTANCE TO: Well Dwelling PERMIT NO. JUZ 02 F Manufacturer Material Liquid capacity in gallons Well f .� Foundatio J.y4 Nearest leek 4- PERMIT. DISTANCE TO: % ..– / L' Lull: U No. of lines � Length of ea in� Total le h ofd, wl Trench < < � Distance bXtf7e n Ines Fw •— � inches F Topof 'le tb f ish grade 6 ' 1ayIaI berg ath�tile �J �/ Total effec ive absorp ' area ,L �, �t�" inches Length Width Depth- - - PERMIT NO. w f7 Q F Type of crib Crib diameter Crib depth Total effective absorption area wa Lu rn Well Building foundation Nearest lot line DISTANCE TO: J Class Depth Driller Distance to lot line PERMIT NO. J w DISTANCE TO: Building foundation - Sewer line Septic tank Absorption area(s) OTHER PIPE MATERIALS A r SOILTESTRATIN- -� / INSTALLER >Gk-,- REMARKS �n 4 n E; y� IOU ROVE'9 DATE LEGAL • nury 11.1 rHL1 I Y Ut' ANCHORAGE Department f Health and Environments ?rotes ion 8251- Street, Anchorage, AK. 9501 264-4720 Permit_ # # HANDWRITTEN PERMIT # # # WELL ANDA" ON-SITE .SEWER PERMIT 14j0G-440A- Applicant:C-GIY (�S®4US�% Mailing Address: s'/e2 d P'4/4_000 01p, Location: Phone umber: °lb's 67 Legal Description: �p%�p - �L Size: -- Type of Soil Absorption System Is: Trench: Drainfield: Seepage Bed: Holding Tank: Maximum Nur of Bedrooms: _ Soil Rating(sq.ft/br) 1' e Required $�e9o0�the Soil Absorption DEPTH LENGTH_. GRAVEL DEPTH WIDTH /v The length dimension is the len g th (in feet) of the N $1+ 9r . trench or drainfield. The depth of a trench or pit is the distance between the surface of the ground and the bottom of the excavation(in feet). There is no set width for trenches. The gravel depth is the minimum depth of gravel between the outfall pipe and the bottom of the excavation(in feet). * * REQUIRED SEPTIC(HOLDING) TANK SIZE _ EX/S�/Y6r GALLONS # # Permit applicant has the responsibility to inform this department during the installation inspections of any wells adjacent to this property and the number of residences that the well will serve. # # # TWO(2) INSPECTIONS ARE REQUIRED # # # Backfilling of any system without final inspection and approval by this departmen will be subject to prosecution. Minimum distance between a well and any on-site sewage disposal system is 100 fee for a private well or 150 to 200 feet from a public well depending upon the type of public well. Minimum distance from a private well to a private sewer line is 25 feet and to a community sewer line is 75 feet. Well logs are required and must be returned to this department within 30 days of the well completion. Other requirements may apply. Specifications and construction diagrams are available to insure proper installation. # * * PERMIT EXPIRES DECEMBER 311 1 9 3 3 I certify that: (1) I am familiar with the requirements for on-site sewers and wells as set forth by the Municipality of Anchorage. (2) I will install the system in accordance with codes. (3) I understand that the on-site sewer system may require enlargement if the residence is remodeled to include more that bedroom Signed: X 4/Qd r Issued by: Applicant 2 Date: SWP/024 (1/81) �`�{'�Q� Jam, Z� L/YJQ// /l �� 'r LA �i , ti' €; � , d �a.M .. (� n nd kj� j �Fi-, PAY C::: DEPHRTMENT HE�TH HND �IO�N p-, / &,O ' HNCHORHGE' STREET "K ^ /' 99501 ^ X W EE: KEE 14 E.— F- u r;=, E>� PEF1,11T HPPLICHNT HL LOCHTION SR '`' Pb LEGAL L�7'6 BLK1 PRUESS �/D � LOT SIZE 20000 SQUARE FEET TYPE OF SOIL ABSORPTION SYSTEM TRENCH MHXIPIUM NUMBER OF BEDROOMS = 4 SOIL FORTING (SQ THE REQ8IRED SIZE OF THE SOIL. ABSORPTION SYSTEM IS: ��F T.. h 4 == � THE LENGTH DIMENSION IS THE LENGTH (IN FEET) OF THE TRENCH OR DRf�INFIEL_D THE DEPTH OFH TRENCH OR PIT IS THE DI -STANCE BETWEEN THE SURF8CE OF THE � GROUND AND THE BOTTOM OF THE EXCHVHTION (IN FEET) THERE IS NO SET WIDTH FOR TRENCHE�S. � THE GRAVEL DEPTH IS THE 11INIMUM DEPTH OF GRHVEL BETWEEN THE OUTFALL PIPE AND THE BOTTOM OF THE EXCAVATION (IN FEET) PERMITAPPLICHNT HAS, THE RESPONSIBILITY TO INFORM THIS DEPHRTMENT DURING THE �L �m�|�A| iUN INSPECTIONS OF HNY WELLS HDJHCEMT TO THIS PROPERTY AND THE NUMBER OF RESIDENCES THAT THE WEL_ WILL SERVE. --------- �W PC0 �_221 I Phi K=x 1" EE=:-. 7- 1 1:101 m: 1=1 lot EEL �? E:---. 0:.,:! 9_9 I F E� BHCKFILLING OF ANY SYSTEM WITHOUT FINAL. INSPECTION Hr�D HPPROVHL BY THIS DEPHRTMENT WILL BE SUBJECT TO PROSECUTION. MINIMUM DISTANCE BETWEEN H WELL AND ANY ON-SITE SEWAGE DISPOSAL SYSTE�4 IS 1U0NFEET FOR H PRIVHTE WELL OR 150 TO 200 FEET FROM H PUBLIC WELL DEPENDING uPV THE TYPE OF PUBLIC 14ELL THE MUNICIPHLITY OF HNCHORHQE, MINIMUM DISTANCE FROM H PRIVATE WELL TO H PRIYHTE SEWER L.INE IS WITH THE CODES TO M COMMUNITY SEWER LINE IS 75 FEET. ON-SITE SEWER SYSTEM 25 FEET AND OTHERREQUIREMENTS MMAYHPPLY. SPEC: IF! C8TIONS AND CONSTRUCTION DIRGRHMS ARE r� �vILHBLE TO INSURE PROPER INSTALHTION� �� F­-�������� I CERTIFY THAT' 1� I HP! FHVIILIHR FORTH BY WITH THE REQUIREMENTS FOR ON --SITE SEWERS HND WELLS HS sET THE MUNICIPHLITY OF HNCHORHQE, 2: I WILL INSTALL THE SYSTEM IN PC. ORDANCE WITH THE CODES IUNDERSTHND RESIDENCE THHT THE IS: ON-SITE SEWER SYSTEM MAY REQUIREENLH��GEMT E�IF THE F.EMODE�ED TO INCLUDE MORE THAN 4 BEDROOMS SIGNED: ------ ISSUED B DHTE_ �� --�—�....-. Wm @GRE' -ER ANCHORAGE AREA BOf 'JGH Department of Environmental Quality 3330 C Street Anchorage, Alaska 99503 SEEPAGE PIT: NUMBER OF PITS DIAMETER OR WIDTH Z�+ , LENGTH 2S, DEPTH LINING MATERIAL L�06 CRIB SIZE: DIAMETER_DEPTH DISTANCE FROM: WELL 1 TOTAL EFFECTIVE BUILDING FOUNDATION, NEAREST LOT LINE 20 ABSORPTION AREA (WALL AREA) &00 SQ. FT. ADDITIONAL ABSORPTION WELL: ll�or MW[d /Pr of 6tyeckel', TYPE CONSTRUCTION BUILDING NEAREST FOUNDATION -,LOT LINE CESSPOOL I19=i10x7 DISTANCES: INSTALLED BY: GU liucC Ccn s l PIPE MATERIAL: GSI SA 1'y4wi LOT SLOPE: REMARKS: Form No. EQ -031 , OTHER SOURCES DISAPPROVED NEAREST SEWER LINE REMA DEPTH SEPTIC TANK_ DIAGRAM OF SYSTEM DISTANCE FROM: SEEPAGE SYSTEM 2 W INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM NAME'a&1 LK4mC �r MAN MAILING ADDRESS +90KEAGLCTPUW PHONE 6gy-Z5'1j LOCATION /� LEGAL DESCRIPTION `rr % 1311C �('� SEPTIC TANK: UL'# I$4g0.3� DISTANCE FROM WELL MANUFACTURER S7gGrc STC -SL MATERIAL CTSS1-- NUMBER OF 72 COMPARTMENTS INSIDE LENGTH INSIDE WIDTH LIQUID DEPTH LIQUID CAPACITY 125-0 GALLONS. SEEPAGE PIT: NUMBER OF PITS DIAMETER OR WIDTH Z�+ , LENGTH 2S, DEPTH LINING MATERIAL L�06 CRIB SIZE: DIAMETER_DEPTH DISTANCE FROM: WELL 1 TOTAL EFFECTIVE BUILDING FOUNDATION, NEAREST LOT LINE 20 ABSORPTION AREA (WALL AREA) &00 SQ. FT. ADDITIONAL ABSORPTION WELL: ll�or MW[d /Pr of 6tyeckel', TYPE CONSTRUCTION BUILDING NEAREST FOUNDATION -,LOT LINE CESSPOOL I19=i10x7 DISTANCES: INSTALLED BY: GU liucC Ccn s l PIPE MATERIAL: GSI SA 1'y4wi LOT SLOPE: REMARKS: Form No. EQ -031 , OTHER SOURCES DISAPPROVED NEAREST SEWER LINE REMA DEPTH SEPTIC TANK_ DIAGRAM OF SYSTEM DISTANCE FROM: SEEPAGE SYSTEM 2 W u � NAME OF APPLICANT INSTALLATION LOCATION LEGAL DESCRIPTION L GREATER ANCHORAGE AREA BOROUGH DEPARTMENT OF ENVIRONMENTAL QUALITY 3330 "C" STREET ANCHORAGE, ALASKA 99503 TELEPHONE 274-4561 SEWAGE DISPOSAL SYSTEM ® APPLICATION AND PERMIT INSTALLATION OF: SEPTIC TANK TYPE AND SIZE OF FACILITY TO BE SERVED FINANCED THROUGH SOIL TEST RESULTS COMPLETION DATE_ ANTICIPATED MAILING ADDRESS PERMIT NO. �4.-_ PHONE 6 ` L2 SEEPAGE PIT_, DRAIN FIELD OTHER TO BE INS''fALLED BY NOTE: THIS PERMIT IS NOT VALID WITHOUT SOIL TEST FINAL INSPECTION: 24 HOUR NOTICE REQUIRED. BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION BY THE DEPARTMENT OF ENVIRONMENTAL QUALITY AUTHORITY WILL BE SUBJECT TO PROSECUTION. SEPTIC TANK SIZE / 2'3-V TYPE MINIMUM DISTANCES, REQUIREMENTS FOUNDATION TO SEPTIC TANK FOUNDATION TO SEEPAGE PIT vy r DRAIN FIELD SEPTIC TANK TO SEEPAGE PIT WALL /y SEPTIC TANK SEEPAGE PIT V" , DRAIN FIELD TO NEAREST LOT.LINE. SEEPAGE AREA SIZE G_.WELL TO SEPTIC TANK SEEPAGE PIT /0 DRAIN FIELD ALSO CONSIDER AREA WELLS. WATER MAIN TO SEPTIC TANK SEEPAGE PIT DRAIN FIELD r r SEPTIC TANK, `� SEEPAGE PIT �, DRAIN FIELD TO RIVER, LAKE, STREAM. CAST IRON INTO AND OUT OF SEPTIC TANK AND INTO CRIB CROSSING GAP OF EXCAVATION 5 FEET INTO UNDISTURBED SOIL. 4 INCH DIAMETER CAST IRON SIPHON PIPES ON SEPTIC TANK AND SEEPAGE PIT FITTED WITH AIRTIGHT REMOVABLE CAPS. GRAVEL SACKF'ILL CONFORM TO BOROUGH REGULATIONS REGARDING INSTALLATION. re �k � G.A.A.B. OR LICENSED DESIGNER TYPE DIAGRAM OF SYSTEM 1 CERTIFY THAT 1 AM FAMILIAR WITH THE REQUIREMENTS OF GREATER ANCHORAGE AREA BOROUGH ORDINANCE NO. 28-68 AND THAT THE ABOVE DESCRIBED SYSTE IS IN ACCORDANCE WITH SAID CODE. (l DATE �2_ J APPLICANT'S SIGNATURE FORM NO. EQ -016 -\ I 229 EAST 51st. AVE. -- P.O. BOX 6087 - ANCHORAGE, ALASKA 99503 TELEPHC IEE07-2 9—'tg3 TELEX 090-35416 Civil Engineers Geologists Land Surveyors JAMES W. ROONEY, P. E. -- _ RALPH R. MIGLIACCIG MALCOLM A. MENZIES, P.E., L.S. Eng;neer!ng Gaoloa_ist JAMES H. WELLMAN, P.E. February�'!�� 8 1974 1}74 R & M No. 462003 -,H k1v65,d. !ty OF PvgEATER ti�1R�'lnard` - - - Mr. Don Zemmerman Box 596 Eagle River, Alaska 99577 Re: Test Bole and Soil Log Report for Sanitary System, Lot 6, Block 1, Puress Subdivision Dear Mr. Zemmerman: We are submitting herewith the test boring results and our comments regarding soil conditions encountered at the subject site. This investigation was performed in accordance with your request of February 5, 1974, and those procedures outlined in a letter dated September 13, 1971 by Mr. Rolf Strickland of the Greater Anchorage Area Borough Department of Environmental Quality. A single test hole was put down within the Lot 6 area for the purpose of defining general subsurface soil conditions for the proposed sanitary system. Excavation was accomplished witha tractor --mounted backhoe and the test hole was extended to a total depth of 17.0 feet below ground surface. The final log prepared for the tett hole has been included in Drawing A-01. Ground water was not encountered in the test hole. We a1,i>'eciaLe ue1_iig g:i.Veti this or:2oLtuit__1_y Lo be OE service CO you. Should you have any questions with regard to the above, please do nor: hesitate to contact us. Very truly yours, R & M ENGINEERING & GEOLOGICAL CONSUL7A TS rn c 611 James W. Rooney J tlx: ph xc: GAAB ✓ R&M ENCI,_,IEERING & GEOLOG9C..l,L CONSULTANTS J 229 EAST 51st. AVE. - P.O. BOX 6087 - ANCHORAGE, ALASKA 99503 t; I TELEPHONE 0—,N.83 TELEX 090-35419 Civil Engineers Geologists Land Surveyors JAMES W. ROONEY, P. E. RALPH R. MIGLIACCIO MALCOLM A. MENZIES, P.E., L.S. Engineering Geologist JAMES H. WELLMAN, P.E. February 8, 1974 �VA R & M No. 462003 F-' .H - A" ITY Mr. Don Zemmerman Box 596 Eagle River, Alaska 99577 Re: Test Hole and Soil Log Report for Sanitary System, Lot 6, Block 1, Puress Subdivision Dear Mr. Zemmerman: We are submitting herewith the test boring results and our comments regarding soil conditions encountered at the subject site. This investigation was performed in accordance with your request of February 5, 1974, and those procedures outlined in a letter dated September 13, 1971 by Mr. Rolf Strickland of the Greater Anchorage Area Borough Department of Environmental Quality. A single test hole was put down within the Lot 6 area for the purpose of defining general subsurface soil conditions for the proposed sanitary system. Excavation was accomplished with a tractor -mounted backhoe and the test hole was extended to a total depth of 17.0 feet below ground surface. The final log prepared for the test hole has been included in Drawing A-01. Ground water was not encountered in the test hole. We appreciate being given this opportunity to be of service to you. Should you have any questions with regard to the above, please do not hesitate to contact us. Very truly yours, R & M ENGINEERING & GEOLOGICAL CONSULTANTS vi James W. Rooney -� JWR:ph xc : GARB / ANCHORAGE FAIRBANKS JUNEAU 3.0' 5.0 030 10.5' 17.0' No Water Table NOTE: Test hole excavated with tractor -mounted backhoe. R Engineering a Geological Consultants Inc. DON ZEMERMAN PROPERT`I 4 ANCHORAGE FAIRBANKS ALASKA JUNEAU LOG OF TEST HOLE Anchorage Alaska DATE 2-0-74 SCALE OWN 9Y SRS CtiKD 8Y WED PROD- NO•. 462004 OWo NO. _ A-01 - 0042273 -_-J ORGANICS of 0 • •. ° SANDY SILT w/Some Gravel (SM) • SAND, Trace Silt (SP) I' o. SILTY SAND w/Some Gravel (SP -SM) o • .o•:o '•o: SANDY GRAVEL Trace Silt (SW) a 0. v.:o SILTY SALAD Some Gravel (SP -SM) o• O . 'l9 • SAND, Trace..Silt -& _Gravel (SP) • 0I• O 3.0' 5.0 030 10.5' 17.0' No Water Table NOTE: Test hole excavated with tractor -mounted backhoe. R Engineering a Geological Consultants Inc. DON ZEMERMAN PROPERT`I 4 ANCHORAGE FAIRBANKS ALASKA JUNEAU LOG OF TEST HOLE Anchorage Alaska DATE 2-0-74 SCALE OWN 9Y SRS CtiKD 8Y WED PROD- NO•. 462004 OWo NO. _ A-01 - 0042273 Municipality of Anchorage Development Services Department j Building Safety Division On -Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519.6650 www.ci.anchorage.ak.us (907)343-7904 A CERTIFICATE OF HEALTH AUTHORITY APPROVAL Iry l9 FOR A SINGLE FAMILY DWELLING Parcell.D. HAA# • /)5701&q - Expiration Date: 7- ;2_3 -05 1. GENERAL INFORMATION Complete legal description (ARE U55 # I L- 01-6 TUK 131 Location (site address or directions) 20233 PA Gi-yr RI VHt2 Rel • EAGLE RIVER, ft Current Property owner(s) QAGEn,E 4r Ri_-pArzn Wh`mi+Cj pay phone 6 — LS%H Mailing address Lending agency Mailing address Real Estate Agent Mailing Address Unless otherwise requested, HAA will be held by DSD for pickup. 2. NUMBER OF BEDROOMS: W 3. TYPE OF WATER SUPPLY: Individual Well C5 Individual Water Storage ❑ Community Class Well ❑ Public Water System ❑ Day phone Day phone TYPE OF WASTEWATER DISPOSAL: Individual On-site a Individual Holding tank ❑ Community On-site ❑ Public Sewer ❑ The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of Health Authority Approval (HAA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of Health Authority Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues HAAs upon request to homeowners. Certificates of Health Authority Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water sample results. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Health Authority Approval Guidelines for this application, shows that the on- site water supply and/or wastewater disposal system is(are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm Eagle River Engineering Servioes Phone1W1 VFW S Address Eaale River. AKQQg-n Engineer's Printed Name C NA'ImPf%R R. Lf oe+� Date Y Iz 7/041- 5. /ds 5. DSD SIGNATURE Approved for __Lbedrooms. Disapproved. Conditional approval for bedrooms, with the following stipulations: Attachments: HAA Checklist X Septic System Advisory Well Flow Advisory Maintenance Agreements Supplemental Engineer's Report Other By: 0":;& , f Original Certificate Date: (R., QJM2) I j Municipality of,Anchorage • Development Services Department Building Safety Division On -Site Water & Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 HEALTH AUTHORITY APPROVAL CHECKLIST Legal Description: f R'E U SS 0 1 1-6 01 RE/)? Parcel ID: CSO- 57/'OLj QWZ1*1t47_V Well type SM Ate If A, B, or C provide PWSID #� Date completed mak. Sanitary seal (YIN)$ Total depth JLC3 ft. Cased to ft. FROM WELL LOG Date of test U PK , Static water level V Nk , ft. Well production V NK. g.p.m. WATER SAMPLE RESULTS: Coliform colonies/100 ml. Nitrate mg./l. Arsenic: mg./I. Date of sample: Ov*61f B. SEPTIC/HOLDING TANK DATA Tank Type/Material S" P q1. Tank size 1250 gal. - Number of Compartments 2 Well Log (Y/N) No Wires properly protected (Y/N) YCS Casing height (above ground) 2 (_in. AT INSPECTION Apr'i1 7, 05 613 ft. 3,7 g.p.m. Other bacteria C? colonies/100 ml. Collected by: Soi+r, 14Ayr>s1V Date installed S &24 Z_q Lf Cleanouts(Y/N) YES Foundation cleanout (Y6) rvv' Depression over tank (YO O High water alarm (Ye NQ Date of pumping APRIL G . O Pumper '7- RAS C. ABSORPTION FIELD DATA Date installed It LOW Soil rating (g744it? or f?lbdrm) i2.S System type TRe NC4f Length Sl ft. Width 30" ft. Gravel below pipe 6 ft. Total depth _IQ_ ft. Eft. absorption area 6jZ-fe Monitoring tube YDepression over field 1yQ Date of adequacy test /Allo/. S. Result (Pas ail) A _5-_ For bedrooms Fluid depth in absorption field before test_ in. Water added gat. New depth in. Elapsed Time:1310min. Final fluid depth ' -L-3 in. Absorption rate >= 6114 g.p.d. Any rejuvenation treatment (past 12 mo.) (Y/N & type) N 0 If yes, give date �� 0—'IFT STATION Date instailed "Pump on" level at _ in. Datum E. SEPARATION DISTANCES in "Pump off" level Cycles tested SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot I Oo �* Absorption field on lot 1001+ Public sewer main 7.5,+ Sewer /septic service line 25 �+ Manhole/Access (Y/N) water alarm level at Meets alarm & i On adjacent lots t� + On adjacent lots t p0' t Public sewer manhole/cleanout 100'4- Holding tank —755-755i 't SEPARATION DISTANCES FROM SEPTIC/110t9141GTANK ON LOT TO: Building foundation Jr e+ Property line 5 �+ Absorption field c - Water main Wells on adjacent lots 100'+ Water service line 10 /+' Surface water 100 0 SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line IDr� Building foundation ���� Water main iI? Water Service line 10 +' Surface water 100 + Driveway. parking/vehicle storage +I Curtain drain 50 + Wells on adjacent lots ISD + F. COMMENTS G. ENGINEER'S CERTIFICATION r certify that 1 have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA HAA guidelines in effect on this date. Engineer's Printed Name C#0r5?nPJF6'n Q. CHROTOPMIt Date y �z �/a 5 ., C''M HAA Fee $ y SO Date of Payment 41X7 /or Receipt Number (Rev. 12101) 4W9*,,e Fee $ 175 - Date of Payment 91 Z 1 10S' Receipt Number Ti'J77 in. 4-20-06:/2:16PM: SCS ReU 1051807001 Mat Name Eagle River Engineering ProjectName/N pre= NI L6 B) Client Sample ID Preuss 1/1 L6 Bl Matrix Drinking Water :807 6616301 0 A- 2 All Doletrnmes are Alaska Standard Time Printed Daterrime 0412012005 8:02 Collected Dsterrime 04/062005 16:30 Received Daterrmte 04/072005 13:44 Technical Director Stephen C. Ede Sample Remarks: EP300 - Sample rerun outside of hold to confirm original concentration. Concentration confirms. Allowable Prep Analysis Parameter - Results PQL Units Method Container M Limits Due Date [nit Waters Department Nitrate -N 0.750 0.100 Kicrobioloav Laboratory Total Coliform 0 mgt EPA 300.0 B (o-10) 04/0905 CAM coV100tnL SM20 9222B A (<-q . 04/07/05 TLF 04/11/2005 14:34 9073449021 JRS SEPTIC JRc Pumping PO Box 773415 Eagle River, AK 99577 (907) 694-6454, Sating IMormatbn -.. 1 Dean Malay Job Description: 12009 Po Box 6700a5 P.O. Number. Chupek AK 99567 Terms: Net 30 (907) 66&1021 Soleerep: Nikole Map Book: -• •1 Cross Streets: ad Glenn Hwy Job slit Infernatton _ Dean for uncle. Larry kladay .. Jab Comments: Last service 21311 GtrW Los Drive wed an In tank Chu0sk,AK 99567 (907) 688.2379 Tax Percent: 68&1021 fax 0 Servw Type Oty Prloe Each It 2 Men Tax Septle Service Under 2K 1 5120.00 No N0 AddlMonel Loa0w Comments: 5th house on left Septic M back Diagram: PAGE 02 Service Agreement Number: 014476 Order Date: 01 -Sap -2004 Sella Dale: 04 -Sap -2004 12:009m ToehnkJan: Tony Job Type Repent Map Grid: 22 pumped tank - busts normal, son" light. Light gravel .._..— --Extension Actual $120.00 Gallons Planned: 1000 Y Gallons Actual: Hose Length: 2.5 Double Tank: ❑ Pump System: Baffles Inlet•. C7 Baffles Outlet: ❑ N"Taxable Total Taxable Total Tax Total Grand Toni Estimated Chargee: $120.00 $0.00 $0.00 W0.00 Actual Charges: Customer apses to the terms and condl6ons Whited on the beds. THIS IS A BINDING AGREEMENT. Signature and Title of Cuslamer Reprseenteeva Dat rte• Accepted by JRs Pumping Dab Accepted For your added convenience we accept: Ammon Express. 0100ver, Visa and Master Card payments over the phone. After 30 Days accounts w0I be fumed over to collections. $25.00 For NSF Checks Returned. ASBUILT—NO CORNERS SET THIS DATE. SLiiARD b ASSOCIATES LAND -SURVEYING 688-4566 I HEREBY CERTIFY THAT I HAVE SURVEYED THE SCALE' FOLLOWING DESCRIBED PROPERTY: 1"=20' Preuss Subd.,Addn. No. 1 Lot 6 Blk. 1 DATE, (�L,�F.A�q �� AND THAT NO ENCROACHMENTS EXIST EXCEPT AS11-10-90 i�e. INDICATED. IT IS THE RESPONSIBILITY OF THE f. OWNER TO DETERMINE THE EXISTENCE OF ANY GRIP: o * -' 4 H' ` ••••.� *0 EASEMENTS, COVENANTS, OR RESTRICTIONS �is / WHICH DO NOT APPEAR ON THE RECORDED SUBDI- 56 �� VISION PLAT. UNDER NO CIRCUMSTANCES SHOULD FB+ : ° '^• ""'*-"d • ANY DATA HEREON BE USED FOR CONSTRUCTION 17-49 �t���'•, LS • 6910 .11i OFFENCE LINES, OR FOR ESTABLISHING BOUND- DRAWN: +1 �' `co ARY LINES. �lki;n�w V. DMS MUNICIPALITY OF ANCHORAGE • Department of Health & Human Services M� i DIVISION OF ENVIRONMENTAL SERVICES — 343-4744 CERTIFICATE OF INSPECTION FOR HEALTH AUTHORITY APPROVAL OF ON-SITE SEWER AND WATER FACILITY FOR SINGLE FAMILY DWELLING Parcel I.D. # 0 v — % /— 0 4 HAA # 1. GENERAL INFORMATION (Must be completed prior to submittal) (a) Legal Description (include lot, block, subdivision, section, township, range) Lot 6• Block 1• Preuss Subdivision J'� Location (address or directions) (b) Property owner Mailing Address (c) Lending Institution Mailing Address %e•��it.i.��a. ia.aC�014w 4awil-._...-_spa AHFC #56370 Telephone: (home) Business Telephone (d) Real Estate Company and Agent HERITAGE REAL ESTATE CORPORATION/Hal Jackson Address 18550 Eagle River Road, Eagle River, Alaska 99577 Telephone (e) Mail the HAA to the following address: (or check here N, if hold for pick up.) List contact person and day phone number below: S & S ENGINEERING/694-2979 17034 Eagle River Road, Suite 204 Eagle River, Alaska 99577 2. TYPE OF RESIDENCE Single-Family4X 3. WATER SUPPLY Number of bedrooms 4 Individual Well U Community ❑ Public ❑ Note: If community well system, must have written confirmation from the State Department of Environmental Conservation attesting to th legality and status. 4. SEWAGE DISPOSAL On-site ® Public ❑ Community ❑ Holding Tank ❑ Note: If community well system, must have written confirmation from the State Department of Environmental Conservation attesting to the legailty and status. 72-025 (Rev. 7/88) Page 1 of 2 5. ENGINEERING FIRM PROVIDING INSPECTIONS, TESTS, FILE SEARCH, DATA AND INFORMATION As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health Authority Approval shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on the date of this inspection. Name of Firm 5u511 Address _Oop �oaa No. 204 Date Telephone ��f�z�r 7 7 6. DHHS APPROVAL Approved for bedrooms by Date lll,�7% Approved �- Disapproved,� Conditional Terms of Conditional Approval v v CAUTION, The Municipality of Anchorage Department of Health and Human Services (DI -IHS) issues Health Authority Approval cerificated based only upon the representations given in paragraph 5 above by an independent professional engineer registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHHS do notconduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 72-025 (Rev. 7/88) Back Page 2 of 2 r. S._,...,,.... 6. DHHS APPROVAL Approved for bedrooms by Date lll,�7% Approved �- Disapproved,� Conditional Terms of Conditional Approval v v CAUTION, The Municipality of Anchorage Department of Health and Human Services (DI -IHS) issues Health Authority Approval cerificated based only upon the representations given in paragraph 5 above by an independent professional engineer registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHHS do notconduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 72-025 (Rev. 7/88) Back Page 2 of 2 A� 90t •f u��MEN� P� � 9® e b A. WELL DATA MUNICIPALITY OF ANCHORAGE (MOA) Health Authority Approval (HAA)' CHECKLIST- FEBRUARY 1984 343-4744 Legal Description: �oT 1JtALJL� l Well Classification1 ti1��,v 7O� Well Log Present (Y& Date Completed UK Total DepthCased to Depth of Grouting If A, B, C, D.E.C. Approved (Y/N) '1 A - Static. Water Level -7O' Pump Set At Yield Z CsPH tt + Casing Height Above Ground 1Z- Sanitary Seal on Casing &N) Electrical Wiring in Conduit Y)N) Depression Around Wellhead (YQ SEPARATION DISTANCES FROM WELL: To Septic/Holding Tank on Lot tom t ; On Adjoining Lots 100 t } To Nearest Edge of Absorption Field on Lot t O o k � ; On Adjoining Lots \moo �` To Nearest Public Sewer Line Ar To Nearest Public Sewer Cleanout/Manhole r -A To Nearest Sewer Service Line on Lot ZS Water Sample Collected by S i S Date 14 -`-10 Water Sample Test Results SA-- i r� 1TT2_.N_T15_S Comments B. SEPTIC/HOLDING TANK DATA Date Installed Size �Zsb No. of Compartments Foundation Cleanout (Ya Date Last Pumped Ik- 15.'l o Standpipes ()'N) —I_—Air-tight Caps &N) Depression over Tank (YQ rI 72- Pumping/Maintenance L Pumping/Maintenance Contact on File (Y/N) ktf ; for ' Holding Tank High -Water Alarm (Y/N) 4 IP-- Temporary Holding Tank Permit (Y/N) A SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK: To Water -Supply Well `� ao To Building Foundation `� L+ � To Property Line t 0 Jr- To Disposal Field �2} To Water Main/Service Line b `} To Stream, Pond, Drainage Course Comments 72-026 (Rev. 7/88) Front Page 1 of 2 a%Y C. ABSORPTION FIELD DATA Soils Rating in Absorption Strata �ZSIi3r� -Type of System Design Date Installed Ip - 6C> -83 Length of Field _ 51 Width of Field Depth of Field — l Gravel Bed Thickness Square Feet of Absortion Area Le 17- Statndpipes Present &YN) \ Depression over Field (Y,A rJ Date of Last Adequacy Test Results of Last Adequacy Test �?cT1SFnsC�D(L�/ Foe- 4 3QS SEPARATION DISTANCE FROM ABSORPTION FIELD: To Water -Supply Well Imo To Property Line t a' To Building Foundation Ic>'} To Existing or Abandoned System on Lot 1C)`- ; On Adjoining Lots -5b't To Water Main/Service Line To Cutback (if present) To Stream, Pond, Lake, or Major Drainage Course �Ot>' * To Driveway, Parking Area, or Vehicle Storage Area Sa '- Comments D. LIFT STATION Date Installed Size im s "Pump Or Level at High Water Alarm Level at Tested for Meets MOA Electrical Cod Comments Dimensions — Manhole/Access (Y/N) "Pump Off" Level at ent(Y/N) Pumping Cycles during Adequacy Test. "Check Permitted Bedroom Rating Against HAA Request" I certify that I have checked, verified, or conformed to all MOA and HAA guidelines in effect on the date of this inspection. Signed Company Date Eagle River, Alaska 99577�� z r�gineer's-Seal MOA No. Receipt No. Date of Payment Amount: $ 72-026 (Rev. 7/88) Back D , CL Receipt No. — Waiver Fee: $ - - Date of Payment Page 2 of 2 � t,. CHEMICAL & GEOLOGICAL LABORATORIES OF ALASKA, INC. 5633 B STREET • ANCHORAGE, ALASKA 99518 • TELEPHONE (907) 562-2343 FEDERAL TAXI. D. #92-0040440 ANALYSIS REPORT BY SAMPLE for Work Order # 30198 Date Report Printed: NOV 19 90 @ 09:08 Client Sample ID:L6 B1 PREUSS S/D PWSID :UA Collected NOV 14 90 @ 17:30 his. Received NOV 15 90 @ 17:35 his. Preserved with :AS REQUIRED Analysis Completed :NOV 16 90 Laboratory Supervise PEEN C. EDE Released By Special Instruct: Chemlab Ref #: 904868 Lab Smpl ID: 1 Parameter Tested ---------------------------- NITRATE-N Sample ROUTINE SAMPLE. Remarks: SAMPLE COLLECTED BY RDJ. Client Name S & S ENGINEERING Client Acct SNSENGP P.O.# NONE RECEIVED Req # Ordered By : R. SHAEER Send Reports to: 1)S & S ENGINEERING 2) Matrix: 91ATER Result Units Method ------------------------------------------------------ 0.14 mg/1 EPA 353.2 1 Tests Performed See Special Instructions Above UA=Unavailable ND= None Detected See Sample Remarks Above NA= Not Analyzed LT=Less Than, GT=Greater Than Allowable Limits 10 pF,�NDFOFNpF Ht G APPLIG -IT FILLS OUT UPPER HAL+ . ONLY Property owner tin ; f,J %1•-_:, .ji,: �=A r Phone Time Zip Code Mailing AddreS Buyer -7e" .,� i_ / i A �¢r !J Date >t_ Date Jd Address �-" ' ! - > p _ 1 i) f �i ZiP Code N . ,• - i Inspector - Lending Institutionu r / 1, Phone / i Zip Code Address -. Co. & Agent-�'...- t._ Phone Realty ENVIROti7•h2NTAL PROTECTION Zip Code Address Legal Description ;% 1 � . f,;:, / �� "r �0 I f- - -- — 7 • / Street Location /i i Type of Residence - - - V2 Single Family RECEIVER ❑ Multiple Family No. of Bedrooms ❑ Other Water Supply I ATTACH WELL LOG. A well log is required for all wells drilled since June 1975. R Individual al For wells drilled prior to that date, give well depth (attach log if available). El Communi y \may. t O Public Utility - ( ) CONDITIONAL APPROVAL' v`D2:3>� Sewer Disposal • Year Individual InQtalled: (`j.r -'• ' Individual When Connected lic.Uiility' ❑ Public Utility :. ❑ Holding Tank -- NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED. rr� /r i. 7- rvr+cc r u cru C -)cod; Z' Time Time Time Time Date Date Date Date Inspector Inspector Inspector - Inspector Field Notes: po � C) c�2gt M-Q� Ca \ ,� p„ - - Qs?� MUNICIPALITY OF ANCHORAGE ll- pEPT, OF Flc!-' TI i ENVIROti7•h2NTAL PROTECTION RECEIVER ( )APPROVED BEDROOMS 'CONDITIONS OF�PPROVAL c� Z p • - \ ( ) DISAPPROVED - ( ) CONDITIONAL APPROVAL' v`D2:3>� DATE BY: Soils Rating Date Sewer Installed Well To Absorption Area Well Log Received Septic Tank Size ) 2 U S Well to Tank 72 02 3 13102) -:,ovember 3, 1983 j,eon osoasTKA 103Falcon Drive Chugiakt AK 99567 Subject: !cit �, dock it 1,-42 on A 'd Uludivis U Approval :Or th(� individual *�ewer and water Lacilities cannot 7 itemn s ave been coi-tipleted; be granted until. the L01101Ying This ujepart, (%,,Itno recocc. J of an on - sItO perfAt being upgy-adod t�jit�)out a pOr i S s u -_ d this Vear. if t�he syste:�.j then you will neod co subl-mit Ongiiieer as-builts of the C� flit 0 ice. it fro,11 this Oft upgrade installation Plur, 00tain a der"" 0 hl,xposed electrical wirk--s to the W011. i`lca' are 1I1"Olat 0 the Municipalitv Of Anchorage codes ayli' lvut be enCaSe in conduit. The se-�?tic tank pupated with a recc-ipt Submitted to this A 'Partlllent. 0 A our (4) inch cleanout needs to be installed to the Sep- tic tank. p� fourns�-all­d to the -1) illc,- cleanout needs to OC' ij act area. -'orfiaie'A on t e n, -xi ting An adeqluacy test needs to be 13c a 0 11 determine ij. the systemis ii� I 1,eac1in1 area. This tUFt v7I u tandards. A Iisting of. - r L adequate DccOrdi",g 0 National 0 I)rivato t),,Is erf porming the test is enclosed. This repo't e. Ilecels to be submitted to this Of'ice for our rcv'--"j Pleane notify t1liF, 1)aparu-iient for a reinsPectioll x7hen th- a if there are any cOrrectu noted discrepancios navtD further qu est,orls, Please call this office at 264--4720. sincerely, cory ' iliisr R-S- Ficting Se%wQr & VVator Program i4anager Ow6/ei/El MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION MHN H URAUL 825 L Street - Anchorage, Alaska 99501 DEPT. OF I-iEPLTH & ENVIRONMENTAL.GiECTION • ENVIRONMENTAL ENGINEERING DIVISION SF• , 1 J '90"1 Telephone 264-4720 REQUEST FOR APPROVAL OF INDIVIDUAL WATER AND SEWER FR g1kgsV - DIRECTIONS: Complete all parts on page 1. Incomplete requests will not be processed. Please allow ten (10) days for processing. 1. PROPERTYOWNER - J PHONE v -'9(i i e'() / ._ MAILING DDRE,�SS� PRO ERTY RESIDENT (If different from ab6ve) i ,- PHONE 2. BUYER PHONE MAILING ADDRESS 3. LENDING INSTITUTION PHONE MAILING ADDRESS 4. REALTOR/AGENT , CL PHONE (Ll NjG ADpRESS Mf_11 '. �/ LPL/ /. 5. LE./ �CRIPTIO , 7� ) / STREET_ LOCATIOG'N ��� r G2 C Cf GC' 6. TYPE" ESIDENCE NUMBER OF BEDROOMS SINGLE FAMILY E] One 1;S Four ❑ Other ❑ Two ❑ Five ❑ MULTIPLE FAMILY ❑ Three ❑ Six 7. WATER SUPPLY �n INDIVIDUAL* * ATTACH WELL LOG. A well log is required for all wells drilled ❑ COMMUNITY since June 1975. For wells drilled prior to that date, give well ❑ PUBLIC UTILITY depth (attach log if availabled , 8. SEWAGE DISPOSAL SYSTEM **If individual/on-site, give installation date `fV, INDIVIDUAL/ON-SITE** If system is over two (2) years old an adequacy test is required ❑ PUBLIC UTILITY by this Department. NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED. 72-010(3/78) THIS SIDE FOR OFFICIAL USE ONLY INSPECTION APPOINTMENTS DATE RECEIVED TIME TIME TIME DATE DATE DATE INSPECTOR INSPECTOR INSPECTOR DIRECTIONS: 1. TYPE_ OF RESIDENCE ❑ SINGLE FAMILY ❑ MULTIPLEFAMILY NUMBER OF BEDROOMS ❑ ONE ❑ THREE ❑ FIVE ❑ OTHER ❑ TWO ❑ FOUR ❑ SIX 2. WATER SUPPLY ❑ INDIVIDUAL ❑ COMMUNITY ❑ PUBLIC UTILITY Connection Verified PERMIT NUMBER DEPTH OF WELL DATE DRILLED LOG RECEIVED 3. SEWAGE DISPOSAL SYSTEM ❑INDIVIDUAL/ON -SITE ❑PUBLIC UTILITY Connection Verified PERMIT NUMBER DATEINSTALLED INSTALLER ❑Septic Tank or ❑ Holding Tank Size:_ 0 O If Tank is homemade give dimensions: SOILS RATING TYPE OF TANK MANUFACTURER TOTAL ABSORPTION AREA MATERIAL , 4. DISTANCES WELL TO: Septic/Holding Tank Absorption Area Sewer Line Nearest Lot Line Absorption Area to nearest Lot Line 5. COMMENTS ❑ APPROVED FOR BEDROOMS ❑ CONDITIONAL APPROVAL (letter must accompany certificate) ❑ DISAPPROVED DATE BY (Title) LEGAL DESCRIPTION 72-010 (Rev. 3/78) Municip-ality of 825 "L" STREET ANCHORAGE, ALASKA 99501 (907) 2644111 GEORGE M.SUL ( IVAN, MAYOR DEPARTMENTOF RFALM AND ENVIRONMENTAL PROTECTION September 25, 1981 Leon J./Arlette M. Osowski Star Route Box 162 Eagle River, Alaska 99577 Subject: Lot 6 Block 1 Preuss Subdivision #1 Approval for the individual sewer and water facilities cannot be granted until the following items have been completed: (1) The water analysis report needs to be submitted to \ �tJ this office from the Chem Lab, 5633 B Street, for our review. (2) The septic tank pumped with a: -receipt submitted to this office for our review. (3) An adequacy test needs to be petformed on the existing leaching area. This test will determine if the system is adequate according to National Standards. A listing of private firms performing the test is enclosed. This report needs to be submitted to this office for our review. If there are any further questions, please call this office at 264-4720. Sincerely, Robert C. Pratt, R.S. Associate Specialist RCP/ljw cc: Helga Larson % Area Inc. Realtors Post Office Box 249 99577 EXCAVATION Area Realty ATTENTION: Hel-& Larson P.O. Box 249 Eagle River, Alaska 99577 Dear Mrs. Larson, WORK ROBERT A. SHAFER CIVIL ENGINEER 694-2979 October 28, 1981 MUNICIPALITY OF A !CHORAG' DEPT. 0= ENVICCTION RECEIVED Reference: Lot 6; Block 1; Pruess Addition #1 Subdivision A sewer system adequacy test was performed on the system located on the referenced property as you requested. The septic tank was pumped and verified to have a capacity of 1250 gallons. The seepage pit was completely full of water with water extending upward into the cleanout pipe. The water could not be removed from the .seepage pit as the standpipe or cleanout appeared to be centered over a crack between two logs which would not allow the pumper truck hose to extend down into the crib. The water level in the stand- pipe was monitored and after a period of 24 hours with the septic tank empty the water level in the standpipe was again monitored and it was found that the water still extended up into the standpipe. As a result of this check it appears that the seepage pit is not functioning adequately and will require upgrading. If we may be of further assistance, please do not hesitate to call. Sinc ely, i 4S"RBERT A. SHAF P.E. /ss cc: Alaska USA Federal Credit'Union Municipality of Anchorage Department of Health and Environmental Protection SRB 196X EAGLE RIVER, ALASKA Eagle River Area GREATER ANCHORAGE AREA BOROUGH�� Department of Environmental Quality 3330 "C" Street, Anchorage, Alaska 99503 274-4561 Date Received May 17, 1976 Time of Inspectior Date of Inspection REQUEST FOR APPROVAL OF INDIVIDUAL SEWER & WATER FACILITIES FOR V.A. 1. Approval requested by: Alaska Mutual Savings Bank o Chris Anderson Mailing Address: Post Office Box 1120, 99510 Phone: 274-3561 2. Property Owner: Leon Osowski Phone: z,� Mile 3 Ea le River Road 70� 7 0/j[06" Mailing Address: g 3. ,Legal Description: Lot 6 Block l Preuss Subdivision 4. Location: Mile 3 Eagle River Road, on left past Eagle River lane 5. Type of facility to be inspected Single Family No. of bedrooms 4 6. Well Data: Individual — serving one A. Type B. Depth C. Construction D. Bacterial Analysis 7. Sewage Disposal System: On—site system A. Installed B. Installer C. Septic Tank: 1. Size 2. Manufacturer D. Seepage Pit: 1. Absorption Area 2. Material E. Disposal Field: Total length of lines 8. Distances: A. Well to: Septic tank CC) Absorption area /11151— Sewer Lines , r Nearest lot line Zd. Other contamination B. Foundation to septic tank Absorption area C. Absorption area to nearest lot line EQ -034 (1/74) Page 1 of two pages Page 2 of two pages - Rei st for Approval of Individual 2r & Water Facilities w Legal Description Lot 6 Block 1 Preuss Subdivision Comments Approved a isapproved Date ' Approval:;Va'lid for one year from date signed Gr ater_Anchorage"Area Borough, Department of Environmental Quality DIAGRAM OF SYSTEM I certify that the information contained in this reauest for approval to be a true and accurate representation of the subject sewer and water facilities and these facilities are operating satisfactorily. SIGNED �l Date EQ -034 (1/74) 1 2 0 9 5. MUNICIPALITY OF ANCHORAGE DEPARTMENT OF ENVIRONMENTAL QUALITY 3330 "C Street, Anchorage, Alaska 99503 - 274-4561 REQUEST FOR APPROVAL OF INDIVIDUAL SEWER and WATER FACILITIES Type of Inspection: CMRO VA xxx FHA CONY Property Owner: Leon OSOWSKI Mailing Address: Mile 3 Eagle River Road Day Phone 277-1313 Name of Buyer: Patrick Richard Maitland Mailing Address: 301 Airport sleights Dr. Day Phone 274-2984 Name of Lending Institution• Alaska Mutual Savings Bank ---Chris Anderson Mailing Address: P.O. Box 1120 Anchorage, Ak Phone 274-3561 Name of Realtor or Agent: *alone Mailing Address: 6. Legal Description: 9 4 Location: Lot 6 Block 1 Pruess S/D Mile 3 Eagle River Road On left past Eagle River Lane Type of Facility to be inspected: SF Water Supply Type of Supply: Public Utility If Individual, number of dwellings presently served If Individual, depth of well Sewage Disposal System Type of System: Public Utility If Individual, date of installation One Phone Individual No. Bdrms. —4 xxx Individual (on-site) xxx **' Please indicate volume of water as acceptable to purchaser. Thank you. EQ -037 (1/74)