HomeMy WebLinkAboutPREUSS #4 BLK 9 LT 3Preuss #4
Block 9
Lot 3
#050-572-57
Municipality of Anchorage 111111 m
On -Site Water and Wastewater Program • (907) 343-7904 MAY 21992 5 of
ON-SITE WASTEWATER INSPECTION REPORT
Permit Number: 05 P 15110 / PID Number: QS0572 5 7
Dwelling: W Single Family (SF) ❑ Duplex (D) ❑ Multiple (SF and/or D) Project: ❑ New D9 Upgrade
Name:
ABSORPTION FIELD Ey,'I_ST/1VG
❑Deep Trench E] Shallow Trench El Bed [I Mound
Address
d Z o 7 b OAIAL L R-4CE
❑ Other
Phone4/—
Number of Bedrooms
Soil Rating
Total depth from original grade
GPD/SF
Ft.
LEGAL DESCRIPTION
Depth to pipe invert from original grade
Ft.
Gravel depth beneath pipe
Ft.
Subdin Blo Lot
RE us
Fill added above original grade
Ft.
Gravel length
Ft.
Township Range Section
Gravel width
Ft.
Beds: Number of Lines
Distance between lines
Ft.
SEPARATION DISTANCES
0
Septic
Absorption
Lift Station
Holding
Sewer
Total absorption area
Number of trenches
Dist. between trenches
From
Tank
Field
Tank
Line
FP
Ft.
Well/
X5-1
TANK Septic ❑ S.T.E.P. ❑ Holding ❑ Other
vv
U
Manufacturer Capacity
Avg d) 6'F_ `- 12-TC)Gal.
Surface Water00(t
D6'f-
,_
Material
Number of compartments
Lot Line
til 4
V
/a r.�-
S 7'E5L
2
NA
Foundation
f
/Q .f-.
LIFT STATION A
Manufacturer
Capacity
Curtain Drain
—
—
--
—
Gal.
Remarks
Pump on level at
in.
Pump off level at
in.
High water alarm at
in.
Pump make and model
Electrical Inspections performed by
Installer
PIPE MATERIAL Housetotank�� Tank to
C drainfield
Drainfield 3O_? CO/MT
Inspector AA*n Eh I
BENCHMARK (Assumed elevation) lie,�Q ft
Inspection ,c
dates: f Q is /.S
Location and description GGd�} J
S A� W 4z_ /'C1_
3m 4Vm
COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL
Enginesamp
t St,tamp
®te
Conditional Approval: Date
o�P� °" e°ALe4
eseee� ..•
Steven W. En�� w
625 . 'z
Approved Date4L
4442L
inspection report-u-i-y4,gcp
W 4/
I
AS -BUILT MEASUREMENTS
A B
FCO 18.5 4
ST1 14 10
ST2 12.5 17.5
DCO 13 20.5
Decc
Sepl
PER
DCC
New
Sepl
R100
NORTHRIM
ENGINEERING
PO Box 770724
j Eagle River. Alaska 99577
907.694.7028
PREUSS # 4
BLOCK 9 LOT 3
49gi.
RECORD DRAWING
REPLACE SEPTIC TANK
1' = 40'
PLAN
LAYOUT
Mla: EET:
5/19/15 2 of 3
N
PA
di
Y
L
d
F-
u U
i-'
a
v
c
v
v
3
N
W
tn
5
O
c
C5
a)
� U
t US 01
0
0� cw U1
W o a
c o
csp > C
d
> W
Ol
W
N
O
L
Y
O
dL
F -E
R O
ON 0
L
0
C5
C5
N
Mm
�a
p� Y
N O
}+ d
L N
O Cl)
d
d L
LD 0S
o U
N L
N Q
n
W)
�Z N�
ZW�oN
c o
W 'a m
�2m e
(3 0 C)
ZW0
(Y)
..
1�
D
m
c
D
U
N
W
O
OL,
J
n
W)
�Z N�
ZW�oN
c o
W 'a m
�2m e
(3 0 C)
ZW0
On -Site Water and/or Wastewater System
Permit
MUNICIPALITY OF ANCHORAGE
Development Services Department
On -Site Water & Wastewater Program
4700 Elmore Road, PO Box 196650
Anchorage, AK 99519-6650
Telephone: (907) 343-7904
Permit Number:
OSP151109
Tax Code Number:
05057257000
Work Type:
SepticTank Upgrade
Permit Effective Dates: May 15, 2015 to May 14, 2016
Design Engineer:
NORTH RIM ENGINEERING
Subdivision:
PREUSS #4
Site Legal Address: PREUSS #4 BLK 9 LT 3 G:0056
Owner/Address: ZUSPAN JERRY
10207 DONALD PL EAGLE RIVER AK 995778772
Site Mailing Address: 10207 DONALD PL, Eagle River
This permit is for the construction of:
N Disposal Field Y Septic Tank N Holding Tank
All construction must be in accordance with:
--/I /9 - / S�
Lot Size in Sq Ft: 19600
Total Bedrooms: 4
N Privy N Private Well N Water Storage
/2, O0
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater
Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80).
3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services
Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either:
A. Open and Close on the same day.
B. Covered, sealed, and heated to prevent freezing.
Received B�
Issued By:
MUNICIPALITY OF ANCHORAGE
Community Development Department Phone: 907-343-7904
Development Services Division Fax: 907-343-7997
On -Site Water & Wastewater Program
ON-SITE SEWER/WELL PERMIT APPLICATION
Parcel I.D. 050 - S TZ — S7
Property owner(s)
Mailing address,
Day phone (9, %4/—Z 9OS
Site address S_A-,0/F
Legal description (Sub'd., Block & Lot) /CiP_UJ-S !!6e Bf j9L 3
Legal description (Township, Range & Section)
Lot Size 9-00 Sq. Ft.
APPLICATION IS FOR:
(0 all that apply)
Absorption Field
❑
Septic Tank
9
Holding Tank
❑
Privy
❑
Private Well
❑
Water Storage
❑
Number of Bedrooms _ %
APPLICATION IS AN:
TYPE OF DWELLING:
Initial ❑
Single Family (SF) P
Upgrades
('N/wo ADU)
(`❑'
Duplex (D) ❑
Renewal
Multiple Dwellings ❑
(SF and/or D)
THIS APPLICATION INCLUDES A VARIANCE /WAIVER REQUEST FOR:
Distance:
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
Permit/Rush Fees: a13
Date of Payment: $-(oI/$
CJvs-
ReceiptNumber: 0$1C[5b
Permit No. 05P15 1101
Permit App_9-1-12.doc
Waiver Fees:
Date of Payment:
Receipt Number:
Waiver No.
a
Tk IR
ENGINEERING MEMO
Date: 5/6/15
To: MOA On -Site Services
Subject: Preuss # 4, Block 9 Lot 3
Septic Tank Failure
Steve Eng, PE, PH
(907)694-7028
SteveEngPE@gmail.com
Number of Pages: 4
The subject septic tank has failed; the homeowners consider it dangerous and are concerned
about ground failure and collapse. Please expedite a permit so the tank can be replaced. The tank
baffles appear broken along with general tank failure. Please review as soon as possible.
If there is need for additional information or clarification please give me a call.
Thanks-SV6
trNIII(G-INEERING
Preuss # 4, Block 9 Lot 3
SPECIFICATIONS & DESIGN GUIDELINES
Wastewater System Sizing: This is an existing 4 -bedroom, single family home. All of
the neighboring lots are developed. The current septic tank has failed- the existing bed is
still useable. These lots are medium sized and are served by private water wells. No
adverse impacts are expected from tank replacement. The 10' utility casement is drawn
on the lot. The new tank will be connected to the existing bed with new DCO's. The old
tank is in danger of collapsing- please rush.
Specification Requirements: All components and work must comply with the
Municipality of Anchorage Specifications (AMC) & State of Alaska Drinking Water
Regulations and Wastewater Regulations.
Existing Septic Tank to be decommissioned. Install new 1250 gallon septic tank with
double cleanouts. Watertight couplings on inlet & outlet.
• 5' minimum between the tank and bed. 10' to property lines. 10' minimum between
bed and foundation.
• 4' of cover or insulation is required for tank; 3' of cover or insulation is required for
trench; an equivalent of 1" insulation for 1' soil cover may be used. 2" Minimum
thickness for insulation.
• Tank & solid pipe must be set on well compacted, stable soil.
• 4 inch diameter cleanouts with airtight caps are required F to 4' from foundation
wall, prior to any 90 degree bend in 4 inch line, in each tank compartment, and two
adjacent opposing cleanouts between the tank and the absorption field, not more than
10' from the tank positioned to provide cleanout access towards the tank and towards
the absorption field.
• All cleanouts must extend to at least ground level.
• In solid pipe runs, ASTM D-3034 may be used in lieu of cast iron.
• Insulation must be placed over any pipe installed under driveways or parking areas.
Approved pipe materials include cast iron, PVC ASTM D3034, PVC ASTM F789,
ABS ASTM D2661,
• Sewer Service Line is minimum 2% slope.
• Septic Tank to be pumped every two years or when required.
• Insulation board to be extruded direct burial polystyrene (Dow Styrofoam HI/equal)
b4 + PS
°ems I
t'° Steven W Eng 4w
�wFQ
DESIGN NOTES:
1. Existing Bed Remains In Place.
2. Sewer Service Line minimum 2% slope.
3. Replace Septic Tank/Decommission Old Tank Per UPC.
4. Lots Served by Private Water Wells.
5. No Conflicts Within 200'.
6. Check Pipe Before And After Septi <.
Replace Pipe If Necessary.
Utility Easement
Well
3% Slope
' ! R1
Decommissio ❑ld L\4 Bdrm
Septic Tank
PER UPC fro
DC❑'s
New 1250 Gallon
Septic Tank >1 0 0
3 Existing
j Bed 0 3% Slope
R100
37 I Slope I
�l
Donald PI,
c
R10e
--- �
°F
PREUSS # 4
„ _ '
1 - 40
NORTHRIM =y��''
*....
PLAN
E
EEo7
BLOCK 9 LOT 3
o BIN .G
';£ogle R7ver, Aoeko 99577
LAYOUT
WASTEWATER DESIGN
907.694.7028 '�«
REPLACE SEPTIC TANK
5/14/15
IME of 3
s
u
C
d
L
F-
oci
Y
C
d
F-
o_
N
N
C
N
N
3
i'
N
W
LA
+'
3
O
C
d
N
U
Cl)
C
N
0
CL
CL
0
0)
F—E
+1
3
O
C
C5
N
U
C
O
dd
a
O
L�
W
W
z
z
W
w
O
W
W
M
0
Z
a
d> -
W w
U Q
Q N
J N
O_ W
WWWW W
Z
°0 W
Y H
U Y
W Z
U Q
U F-
�
O
U
~ C
O)
V1 J
C
C
O
i-
LA
+
CJ
LI
)U
W
a) W
p
W pL
~
d ) d
a O i
U.'Fi-,
U N
._
O U S
d
X W
N
CL
0
0
W
J
H
a z
oo� w
a_ :5::
J
�Z U
Z Q
Q J
J
U
H
� Y
� z
W Q
F—
MR
U
f
a
v
u L v
u v m
d ) d
a O i
O U S
U u
C
O
a N p U
J a
u d
U O )' Z
N C
dai
cs
i a
(/ H
N Li
N U N
C N
a C 0Y
0-5 3
and
+aoac a�
3
L7S LT
a U
_aE W-Pi.4- U
CD U Ln cW
a u, Ln
ms £ U a
NQD
a4 N �N p0t%1
O a'aC4-
75 U i -L p O CO dl a
W-6LW NU aU NO
a -Y = .> 4' U p ' C
S
V1
W
C C p i L+ F- N
+. d (i7 N m "U E Ui
0
VI F- a 0� a, i al T
Z
w U s1 i O ms £
3
LZ7
a, (I d, 3 d al aj OU
°c�'3cna�A
� i0
W
0
0
W
J
H
a z
oo� w
a_ :5::
J
�Z U
Z Q
Q J
J
U
H
� Y
� z
W Q
F—
MR
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND HUMAN SERVICES
Environmental Health Division
825 "L" Street, Anchorage, Alaska 99502, Telephone 264-4720
ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION
REPORT
Name -
DISTANCES
r t
TO
FROM
SEPTIC
ABSORPTION
WELL
Address
O zO _. ONI J
_
C' S
TANK
FIELD
Phone(s))
-
Permit No. o. of Beddro
oms
WELL
��
F� �
LOT LINE
c) . .
LEGAL DESCRIPTION
Block
Su division
of
.3
-
r S �
FOUNDATION
,� ' f
—) t
Township, Range, Section
)
N'17'
AS -BUILT DIAGRAM (Show location of well, septic system, property lines, foundation,
1 kA
driveway, water bodies, etc.)
TANKS
Co 02 Co 3 CoNET
SEPTIC ❑ HOLDING
e , 5C 5 I?
B Jae I a ✓1 .,1' 645
37 0 /2 5
50 pe
Manufacturer
Capacity in gallons
S l AI
2
C
Material
No. of Compartments
TYPE OF SYSTEM
❑ TRENCH BED ❑ W. DRAIN ❑ OTHER
Depth to pipe bottom from
Total depth from original grade
original grade r
!
FT
FT
Fill added above original grade
Gravel depth beneath pipe
FT
. S FT
Gravel length
Gravel width
Z (o FT
FT�
S
Total absorption area
Distance between lines
g SO FT
FT
IE5-
f O C .i/
!7
At R50 +l �®
Number of lines
Soil rating
Pipe material
5
I L4 C) SQ FT
S VG
CYAJ. 5 FPj IC
Installer X9n QL19
7L
Date Installed
C S
ROc I p
1)- C) c C)
WELLS .,'= ;;;
C6 3 e _
❑ PRIVATE E) OTHER (Identifv) �e
Im
I Z
xlS s I*FACI—
Classification (A,B,C) Depth Cased to F EL
I
N FT FT
+Da
installer'- nstalled:
REMARKS:'IT
I
D(bNIALD6
L �^ Scale: T
�/
ENG
T/1 1 1 Inspectlo erformed by:
i
Date: j
G( lj'
° e
yf� r'S n "� N �p • �)[
certify that this inspection was performed according to all
51 °
i4fi.
Wi bvi$ A, ih:a�A4
S1k�erUlGe9fi
irfpgi °dl"��IPel r ylis date:No.
t<'a -s ' !Z •.
_
LHealth
s
'3
Department Approval: Date:
;a• Jt ��"} x „�"
G -V 10 (J/oo)
` MUN1L,1PAL1.TY U F: �N C It i 0 11'. "j, 'L�.
Department o{ Health & i Services
825 L Street, Anchorage, Alaska 99501 343~4720
0N-3ITE SEWER PERMIT
Permit Number: 90O298Upgrade —
A con
Date Issued: 09/1B/90 Engineer Desipned
Owner Name: JERRY ZUGPAN Day Phone:
Owner Address: 10207 DONAiD PLACE 753�2660
EAGLE RIVER, AK 99577
Parcel Id: 050~572~57
Lnt Legal: Subdivision: PREUSS #4 Lot: 3 Block: 9
Section: 8 Township: 14N Range: 1W
Lot Size i9600 (s;"4t. or acres>
Max 8edrooms: This Permit: 4 Total Capacity: 4
SEPTIC TANK: Minimum total septic tank capacity: 1�250 gallons. Each septic
Lank must have at least 2 compartments" Depth to top of septic tarot (s) < 4,0
feet requires insulation over tank(s),
THIS UPGRADE BED SYSTEM MUST BE INSTALLED AS SHOWN ON THE
ENGINEER'S AMENDED DESIGN DATED 9/8/90. DHHS MUST BE NOTIFIED
UEFOKE ALL lNSPECTIONS, [HIS PERMIT IS FOR A 4 BEDROOM SIN8LE
FAMlLY RESIDENCE ONLY, AND EXPIRES ON 12/3/190.
l CET.[IFY THAT:
1. I am familiar with the requirements for on-site sewers and wells as set
forth by the Municipality of Anchocage (MOAI and the State of Alaska^
2" I wiil insta]l Uhe system in accordance with all MOA codes and reguiations�
and in compliance with the design criteria of this permit"
3, I will adhere to all MOA and State of A1aska requirements {or the set back
distances from any existing well; wastewater disposal system or public
sewerage system on this or any adjacent or nearby lot.
4. I understand that thiermit is valid {or a maximum o[ 4 bedrooms` l
a1so understand that the capacity o� the totaI system is 4 bedrooms and
any enlargement will require an additional permit,
���
DATE:
DATE:
/OUtl ilhi E SMT
j
,O Z
¢
v s
Q p
N
s -y-+= a
:z
�9
4
O
�V3
��'a
u_
Q) 0...
0)
4:0 4?
;a-4
ecu s��
/OUtl ilhi E SMT
IJoN€�lci A�JRce
0
3
vn,
:z
�9
4
O
42
T
_
41 0
u_
Q) 0...
IT '`---
I
f- s
—I—
0i
ii
v
2
v
oj
�� V'
y �
5.�4-+-y�j
7
a
_
°Ap
IJoN€�lci A�JRce
0
3
,Ok'=r,
O
42
T
_
41 0
'O 0
Q) 0...
Vs V) �
—I—
;-
0 2
2
v
oj
�� V'
y �
5.�4-+-y�j
7
a
_
°Ap
o
�
a
J
,Ok'=r,
%SQ SEAL)
Municipality of Anchorage gy CJ (= 'pv
DEPARTMENT OF HEALTH & HUMAN SERVICES 0 `Pa r s f{
825 "L" Street, Anchorage, Alaska 99502-0650 °°°°°^=°
SOILS LOG — PERCOLATION TEST d °•°°°° °• F,°°.°..°
r _ ;loberi A. Shox, 1 ;
PERFORMED FOR: DA 'PERF"
"°°4i I a
-�
LEGAL DESCRIPTION:/—c) _�,R(k�t'• ��r)C % { 1 Township, Range Section:
DEPTH SLOPE SITE PLAN
1
2
3
4
5
6
7
8
9
10
11
12-
13-
14-
15-
16-
17 -
18-
19-
20
2•13•14-
15-
16-
17-
18-
19-
20 -
COMMENTS
0 R
70 wlbjht-sll�
141001's (�r
VJz() 5 e.qS
WAS GROUND WATER
ENCOUNTERED? Lj e,
IF YES, AT WHAT
DEPTH?
Depth to Water After _
Monitoring?. Dale: `3
H
Reading Date Gross Net Depth to Net
Time Time Water Drop
PERCOLATION RATE (minutes/inch) PFRC HOLE DIAMETER
TEST RUN BETWEEN �..{T AND FT
PERFORMED BY: 17034 Eagle River Loop koact tN c,
Eagle River, AInke 9957-7
ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDED
72-008 (Rev. 4/85)
CERTIFY THAT T IS TEST WAS PERFORMED IN
,/�
ON THIS DATE. DATE: �6
11V♦,1� I1 ALM Vl' L11Y V S1Vlt[iUL
Hea h and Environmental Prote( '.on
Fourth Floor West
825 L Street
Anchorage, Alaska 99501
264-4720
INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSiIZPA -
NAME MAILING ADDRLSS ��p1n�IONECJ �G� 9> MAO
LOCATION D{)_!Iu W {__�. LEGAL. [�f:SCf21Pl ION-_ •'_ �_p PIC.-1�,.'�l _,�,— -
SEPTIC TANK:
DISTANCE NUMBER OF
FROM WELL-l�D ___ MANUFACTURER MA
INSIDE LENGTH_____-._._ INSIDE WID1-11 '_ LIQUID DEPTH LIQUID CAPACITY_�tJ6�ALLOfJS.
/ 1 7- i TOTAL LENGTH �
DISTANCE f=ROM WF__L-_/!_�__--FOUNDATION�.5__NEAREST LOT LINE_._`_Q-______-O,= LINE
# of Lines DISTANCE BETWEEN LINES h____TRFNCH \:'IDTfI 6 IN. TOT AL EFFECTIVE
ABSORPTION AREA ___-_ _d6 -------- - SO. FT. LENGTH OF EACH LINE
DEPTII OF FILTER, _
DEPTH: TOP Of= TIE L TO f WISH GRADE t MIATERIAL BENEATH TILE -t°d�ABOVE TILE
SEEPAGE PIT:
DIAMETER OR WIDTH
LENG I FT-_, DEPTH
Log Crib Rings` Crib Size: DIAMETE:.R___-_DEPTH__._ DISTANCE FROM: WELL______.
TOTAL EFFECTIVE
BUILDING FOUNDATION , NEAREST LOT LINE ABSORPTION AREA (WALL AREA)
Well di-J'llell
Class Depth
Well Distance To: Lot Line
Bldg: Sewer_ Line:
Pipe Materials: Cf ,
# of Bedrooms: t�
Installer:
Remks:
i�v
►� �. l i
'-
i
'III Ii��
III lil��I
t E !
rt
�! j'..I_1t.ltt�.11litlt nt'It
tI}
t ';i
I
iii
II!l
o:
�r
�crn�/ncm/ ' ncn�/n
nm., c/v,.Pmo,/c.�/n�
-mu.r/fun
STHEET,
H�CHORHGE/
HK
9�
PFRh)T NO ( 77508)
u/
���
~-
����~ �ox
p
HPPL`
I�HNT
|OCHTION DONHLD P|HCF
`
iEGHL L] B9 PREUSS
SUBD
LOT SIZE
19200 SQUHRE
FEET
TYPF 0F SOIL HBSORBTION
SYSTEM
M TRENCH
MHXIMUH NUMRFR OF BFDROOMS
I 4
SOIL
RHTING (SQ FT/
FOR )"s 100
THF R&M IRED SJZE OF
THE SOIL HBSORPT}ON
SYSTEM IS�
LJOESs"701-1-1:=0
A& wS
121 FRIA Is
0570. R >
OPT WS" -7- 1-1 141
`
THE LENGTH DIMFNSICIA
IS THE
LENGTH (IN
FEET) OF
THE TRENCH
OR DRHINFIFLD.
THE COFPTH OF H TRFNCH
OR PIT
IS THE DISTHNCE
BFTWEEN
THE
SURFACE OF
THE
GROUND HND THE BOTTOM
OF THE
EXCHYHTION
(IN FEET)
THERE IS NO SET WIDTH
FOR TRFNCHES
i
THF GRHVFL DEPTH IS
THE MINIMUM
DEPTH
OF GRHVEL
BETWEEN
THE OUTFHLL
PIPE
HND THE 8OTTOM OF
THE EXCHVHTION
(IN FFET)
AN INT M;-1 : 4: 1 f U h > 54, OFF
poll -w- :1 10
-1- w? 141 K
40, 3: Z27 ho:,=,
71. SO
771 WEI KA FyU- A-,
~
IDI41 AT
`
��ji:�;e I;,. P � ii g ' �P:: g � P:;' ?� 11--l' 40 197 10 127 1-1 PRO PEE IT is J �. ED W,X!
by
A & L DRILLING COMPANY
BOX 97, EAGLE RIVER, ALASKA 99577 • TELEPHONE 694-2588
OWNER OF LAND G' (.)P,! 1=S f� ��f f r�%� DEPTH OF WELL r�
i
l ' STATIC LEVEL OF WATER FT.-
ADDRESS =S .7 �' L 1"
LEGAL DESCRIPTION ;L?/l�.
r
DATF, -Started � �`'i/��/� h Ended , /
PERMIT NUMBER w"
KIND OF FORMATION:
DRAW DOWN FT.
GALS. PER HR !
KIND OF CASING G f'l (,)()
From t.,'
Ft. to- Ft.
b 064
eel `l
From
Ft. to
Ft.
From -i)-
Ft. to–/ �Ft.
)-0
Ft. to
From
Ft. to
Ft.
From j �Ft.
to ', Ft.
('4,4 %
° f: f/ 46-,
From
Ft. to
Ft.
From i.',
Ft. to z' Ft.
tI, 43'
From
Ft. to
Ft.
From
Ft. to
Ft.
From
From
Ft. to
Ft.
From l,'?•
Ft. to-TA—Ft.
From
6&Ia t. I?` W#7161From
Ft.
Ft. to _
Ft.
From
Ft. to
Ft.
From
Ft. to
Ft.
From
Ft. to
Ft.
From
Ft. to
Ft.
From
Ft. to
Ft.
From
Ft. to -
Ft.
From
Ft. to
Ft.
From
Ft. to
Ft.
From
Ft. to
Ft.
From
Ft. to
Ft.
From
Ft. to
Ft.
From
Ft. to
Ft.
From
Ft. to
Ft.
From
Ft. to
Ft.
From
Ft. to
Ft.
From
Ft. to
Ft.
From
Ft. to
Ft.
From
Ft. to
Ft.
From
Ft. to
Ft.
From
Ft. to
Ft.
From
Ft. to
Ft.
From
Ft. to
Ft.
MISCL. INFORMATION:
DRILLER'S NAME