Loading...
HomeMy WebLinkAboutPROSPECT HEIGHTS BLK 1 LT 14Pro p ct Height Block Lot 14 #015-091-05 Municipality of Anchorage .',.. Development Services Department :'~' ' ". Building Safety Division On-Site Water and Wastewater Program, 4700 S. Bragaw SL P.O. 8ox lg66,50 And~oeage. AK 99519-6650 Page / of ~w.d.ancflomge.ak.us (907) 343-7904 ON-SITE WASTE3NATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number, SW050285 PID Number, 015-091-05 Name; I David Alexander Wastewater System: [] New [] Upgrade 9601 Prospect Heights ABSORPTION FIELD LEGAL DESCRIPTION b",,~ ~ 1 ux 14 ~'~"=-'* Prospect Heights ~,~.~,~,,,,,,e,~,.~. Well: [] New [] Upgrade ~'~'"~: ~" ~'~'~' ~. A+ Home Services Oct 28, 2005 SEPARATION DISTANCES [] Septic [] H~ding [] S.T.E.P. [] Olher:. Tank Field Sta~n Tank Sewer Une Anchorage Tank 1250 e~. w,, 176' 122' N/A N/A 100% Steel 2 ~.,.w. N/A N/A N/A N/A ~ / LIFT STATION ~ ~ 33' 32' N/A N/AX ~" F,,~.= 16' 30' N/A N/A 'P"'~ "'""" ~- '~'~' ~,'.~ Old tank buried on site. No change to drainfield. BENCH MARK Tank and line insulated with 2" rigid foam. ~'='~ ~""'"'~ NW Garage Sl~b ~ ';. ; /. Engineer's Stamp Inspections performed by:, Cindy W. Ellis, P.E. Dates: 1" 10/28/05 , ~~ D~¥~lopmant Ser~ice~ Departmant Approval Revlewedandapprovedby:&x_~ ,, ~"~,~') e(').d3ate: ///~//,-~CV, 'L~\ Cin.d_~ W. Ellis.~ NO change lo drainfleld ~ ~ DCO 31.9 36.0 Retard Drawing of~p~c Upgrade David ~ander Watkins Engineering, Inc ~ ........... ~.~ Parcel ID N~ 015~91~5 ~::~ ~,~"~ Permit Numbe~ ~050285 ~....' .............. :....~ ~ ~. 'V'~,~;"~.'[[~i~'";"'~, December 12, 2005 Anchorag~ Alaska 99511~443 ~. ".. ..'",. ~le 1 Inch - 40 ~ Phone: (907) 349-1851, Fa~ (907) 349-1934 A B FCO 8.0 16.3 STI 17,? 24.5 $T2 26.2 31.4 DCO 31.9 36.0 CO 32.2 37.3 MTI 80.0 ?0.0 MT2 131.~114.5 FCO ST 1 97.99 FINAL GRADE 100.86 ST2 / INSULATION 1250 GALLON STEEL SEPTIC TANK DCO N.T.S. To Existing Drain field AS-BUILT Prospect Helghts Blk 1 Lot 14 Record Drawing of Septic Upgrade David Alexander · .. Parcel ID: 015-091-05 Watkins Engineering, Inc ~i.~.-. ~'-,os, ..;y Cindy W. Ellis, P.E. P.O. Box 110443 ~....... ...,.? December 12, 2005 Anchorage, Alaska 99511-0443 No Scale Phon~ (907) 349-1851, Fax: (907) 349-1934 MUNICIPALITY OF ANCHORAGE Development Services Department On-Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 9951~.6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Upgrade Date Issued: Aug 15, 2005 Expiration Date: Aug 15, 2006 Permit Number: SW050285 Legal Description: PROSPECT HEIGHTS BLK I LT 14 Design Engineer: 0844 Watkins Engineering, Inc Owner Name: DAVID ALEXANDER Owner Address: 9601 PROSPECT HEIGHTS ANCHORAGE, AK 99516-1063 Parcel ID: 015-091-05 Site Address: 009601 PROSPECT DR Lot Size: 108800 SQ. FT. Total Bedrooms: 4 Permit Bedrooms: 4 This permit is for the construction of' [] Disposal Field [] Septic Tank [] Holding Tank [] Privy [] Private Well [] Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. 5. The following special provisions. -SEPTIC TANK INSTALLATION MAYBE LOCATED NO LESS THAN FIVE FEET FROM ANY PROPERTY LINE OR BUILDING FOUNDATION; TEN FEET FROM ANY WATER SERVICE LINE; ONE HUNDRED FEET FROM ANY SURFACE WATER; AND ONE HUNDRED FEET FROM ANY PRIVATE WELL; AND THE SEPARATION DISTANCES REQUIRED BY 18AAC72 FROM WATER SUPPLY WELLS. Municipality o. fAnchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907) 343-7904 ON-SITE SEWER/VVELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. 015-091-~5 Permit Number SW Property owner(s) David Alexander Mailing address (l~C~(~Ot- ~'~'c~[3~(~ ~la~ng address (2) Day phone .Zip Code Legal description (Lot, Block & Sub'd.) Prospect Heights, Block 1, Lot 14 Legal description (Section, Township & Range) Lot Size 108,800 .A~e~ Number of Bedrooms 4 THIS APPLICATION IS FOR: Sewer Only Sewer and Well Sewer Upgrade THIS PROPERTY CONTAINS: Hot Tub Swimming Pool Therapy Pool [] Well Only [] [] Water Storage [] ri Jacuzzi [] [] Water Softening Unit [] [] I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. (Signature o7 propert~bwner or authorized agent) Permit Fees: ate of a me.t: Receipt Number. (Rev. 12~X)) Waiver Fees: Date of Payment: Receipt Number. Watkins Engineering, Inc. P.O Box 110443, Anchorage, AK 99511 (907)349-1851 cwellis@gcl, net August 8, 2005 Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program P.O. Box 196650 Anchorage, AK 99519-6650 RE: Prospect Heights, Block 1, Lot 14 Proposed Septic Tank Replacement To Whom It May Concern: Attached please find an application to install a new 1250 gallon steel septic tank at the referenced 4 bedroom house in Anchorage. The existing septic tank, installed in 1987, has collapsed and will be abandoned in place. The new tank will be placed more than 100 ft from any private wells. No work is proposed on the drainfield. I am not aware of any adverse effect that this septic upgrade would have on any adjacent properties' water and wastewater treatment needs. Thank you for consideration of this permit application. need further information, please call me at 349-1851. Yours truly, Cindy,S/. Ellis, P.E. President If you have any questions or Prospe~ Heigh~ Blkl Lotl4 DavidPr°p°SedAlexanderSeptic Upg~de - Site Plan Watkins Engineering, Inc ....' ............ z.~ Cindy W. Ellis, P.L P.O. Box 110443 August 8, 2005 Anchorage, AK 99511-0443 S~le 1' - 100' Phone: (907) 349-1851 Fa~ (907) 349-1934 No work proposed on drainfield. MT1 Existing 1250 Gal Steel Septic Tank Proposed new (1987) 1250 gal steel Collapsed septic tank To be abandoned w/DCO in place. (.~,~Existing R House / / Prospect Heights Blkl Lot14 ~-~...O...F..~.~ ::,~,, Proposed Septic Upgrade Watkins Engineering, Inc. David Alexander ~'o~..". 49 Ondy W. Ellis, P.C P.O. Box 110443 August 8, 2005 Anchorage, Naska 99511-0443 S~c 1 inch - 30 ~ Phone: (907) 349-1851, Fa= (907) 349-1934 MUNICIPALITY OF ANCHORAGE DL .-~RTMENT OF HEALTH AND HUMAN SERwCES C/ / Environmental Health Division ~)/,~ 0 825 "L" Street, Anchorage, Alaska 99502, Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Name Address LEGAL DESCRIPTION Lo,/,/. i B,OCkl Township. Range. Section TANKS SEPTIC [] HOLDING No. of Compad'~s'~~ TYPE OF SYSTEM []TRENCH [] BED [] W. DRAIN [] OTHER Depth to p~pe bottom from Total depth from original grade original grade DISTANCES WELL LOT LINE SEPTIC TANK ABSORPTION FIELD WELL FOUNDATION AS-BUILT DIAGRAM (Show location of well. septic system, property hnes, foundabon. driveway, water bodies, etc.) FT Fill added above original grade $~ FT Number of hnes Soil rat,ngSO FT Installer FT r..eraVel deplh beneath p~pe FT I w~dth P~pematerial Date Installed WELLS FT FT ~'~ PRIVATE Classdicatio~TA,~, C~ [] OTHER fldentifv) jTotal Depth Cased to FT FT REMARKS: I~unicipal and $1ale guideline8 in elleet en this date: Scale; Inspections Performed by: Date: cerlily that Ihis inspection was pedormed according to all Health Department Approval; '~~ ~¢~' ~'7¢''¢'''''~'~'~ Date:  MUNICIPALITY OF ANCHORAGE " DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION ENVIRONMENTAL ENGINEERING DIVISION 825 L Street - Anchorage, Alaska 99501 Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT NAME IP_HONE [] NEW LEGAL DESCRIPTION LOCATION NO. OF B~z~OOMS '7 Well J// Absorpt~on~.~srea, Dwelling PERMIT NO, _O .~ DISTANCE TO: ~ ~,/.~../( ~/~4~/~/~.~/(~./ I- 2 Manufacturer No. of co.p~partments Liq.,/capacity~/~in gallons IF HOMEMADE: Inside length Width Liquid d~h I~ ~ DiSTANC~ Tr~: Well Dwelling PERMIT NO. ~OZ"~-- I- Man ufo.'dC-er ..... Material .... 'Liquid cap~acity i~ §ailons I:1 Well Foundation Nearest I~/t ~e / PERMIT NO..¢_¢. -~ .~ ~ ~ No. of lice, Length of e~hL~j~,~ Total length ~ I~/~e~ Trench width~-'- .~.- D ist,. o e b e ~.~e e .n~,i % l- ~ Top of tile to finish gradeI . ,~~ Material beneath tile Total effective absorption area 12 ~) inches Length Width Depth I PERMIT NO. ~ I- Type of crib Crib diameter Crib depth Total effective absorption area u~ Well Building foundation Nearest lot line ~ DISTANCE TO: -I Class Depth Driller Distance to lot line PERMIT NO. ~ DISTANCE TO: Building foundation Sewer line Septic tank Absorption area(s) OTHER PIPE MATERIALS INSTA. L,~ER ,~ I REMARKS APPR DATE LEGAL F:iPF'L. i CFINT LOCRT ! ON L. EG:F~L L±4 E;LOCK :i. F'ROSPEC:T HTS L 'iT :F:ZZff ::..:.~99':'"9:5' SQUFiRE FEET THE LF.:HGTH [:,:r. HENSZON iS THE LENGTH (IN FEET::, OF THE TRENCH OR [:,RFaIi',,!FiEL.[:,. "!"Hr:: DEF:'TH OF FI TRENCH OR PiT IS THE DiS'TRNCE DE:T!4EEN THE SURFF:ICE OF' THE GROUI'.,iD RiqD THE E!',OTT'OFi OF 'THE E::.~:C:FI',,,'FiTZ ON ( I f.,t F'E:E TF!E GRRYEL C, EF:'"FH IS 'THE i"IINIi"iL!H DEPTH OF GRff,,,'E[.. BETi.,.IEEN 'THE OUTFP3LL. F' FIND THE DOTTOH OF THE E::.::CFiVRTION (iN FEET). F'ERH i T RPPL.. ii "_4-, ...... ~T. F,~"~'-':..:: "17-._F:' RE:,f-'bl-,!::,-' "--'""'" .... i E '.r L i '! "9 T'O ._T i'.fF' _.,"~.'1',i., .... TH T '1~ [:,EF'F!RTHENT r"~ F' '[~ ~.Jr:~. ]"HE I NSTFiLL. F!T :i: ON I !'q:L:;F'i:-~CT 1[ 7m~t'.-'ii; OF !::i?.~? WEL. LS .::!i'j:,J'~:IiTj:[(~.,!T 'T'ij) TH i :Fi; PR Z PE!:--::]".? FIND THE ~' ....... F-' H i'LL. ' .......... .~-~!i.~Ii','![E~E~I;i: OF ~.E::, i .F:,EF!CE:5 THFIT THE BFCh'ZF ILL ~ !'.;!G (::iF' .,':~Nh.' S'gSTEH k! ! '~k~']l rT' r-. .................... ['~::F:,,-::;,]'vti:i,.'r' i'.J]~L.L [.:.IE ...... c,....L, ..... i'Ll F;'I;""':;F- TT-!'-i i"iiNIHLIH D!STF!NCE BE:CT'WEEN .R WELL. FIND FIN"? Oi",!-SiTE SEi.,.!F~GE DiSF'OSFfi_ S'.tSTEH iS :!.O!Z[ F:'EET FOR F! F'R;!:',,,'FFt'E I.,.IEL.L (:IF'. ±50 TO 200 FEET :'7:'RCff,i F! F'L!ErL. IC: i.,-IEL.L [:,EPEI'.~;[":,i?',iG UF'ON ']"HE T'.r'PE OF F'ijE-~!_!C: HEL. i. .... !'"!i!'.,l!hlL.!f'1 [:,:[ST'ffINC:E FF:-:OH F~ F'Ri',,,'Ira'YE 14ELL. "i"O FI F'R!',/FiTE '.:SEI,.!ER LINE IS 25 FEET F:Ii'..!D TO Ft COhiPiUi'q!T'9 SEI.,.!ER I_:~:i'..iE !:5 Z5 FEET. OTHER REQU t REiqENTS FiF!'Y F:!PPL?. SF'EC i F' l CF!T !' OF,l?.; Ri'.,!D E:ONST'I:~'.UCT :[ (:il',,! [;, I F:lL:i.,q'.F~H:i!i; IbRd!: R',,,'R I L. FJBLE TO l N:E;URE PROPER ]: i'.ii~;TI:3L.L. FIT t Of',.". I' CER]"ZF? THFIT :L: I Ftf"i FFIHILiIRP:: !,.!:['.I*I-.I THE ff.'.EE:!LiIREHENTS FOF: ON-SITE: SEWERS !raNI:, HELLS F!S .':_':;El" F'OF,'TH Bh.' T'HE Ht..iN:.r. CIF'RLIT? 0i::' F~I'.,iC:HCiRFI. C~E. 2: i .H~L.L :U'.,!STRLL. ]"HE Sh.'STEF! IN RCCORDFi!'.,!C:E !.,.iiTH THE CO[:,ES. 3: i L.i!'.~DEF,-:ST,q,N[:, "FHFFF THE (iN-SiTE SENEF: SVST'F£H .r,IR'.:' F.-:E(:!U]:F.':E [ENL. F~,RGEHENT :iF:' 'T'F!E RES l DF2:N.C:E i S RE!"iCff>ETLEi2, TO i NCLL![>E HORE THFiI'.,! RPPL :i: CRNT' i,.ff:!!-;:REN C CO!_VER T,::;q ,~:i'", , ,~' ',.,'4- ............. . ~::~ .. . . .... ... J , MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION 825 L. Street, Anchorage, Alaska 99501 264-4720 SOILS LOG- PERCOLATION TEST SOILS LOG PERCOLATION TEST LEGAL DESCRIPTION: 2 6 7 8 SLOPE SITE PLAN 10 11 12 13 14 15- 16 17, 18- 19.- 20- COMMENTS WASGROUNDWATER ~ ENCOUNTERED? r~-() o P E IF YES, AT WHAT DEPTH? Gross Net Depth to Net Reading Date Time. ~ Time mt'~ Water Drop ,~zoi.! (o.l(~.~Z?_z:~dz:~,~' ~ /~o ,~ /,~0 '~ /.d? PERCOLATION RATE / TEST RUN BETWEEN ,'E.EORMEDB'.': C.o,n , r 'v CERT.E,EDOY: (minutes/inch) .T AND ~,5--' .T MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION 825 L, Street, Anchorage, Alaska 99501 264-4720 SOILS LOG- PERCOLATION TEST PERFORMED FOR: · EGA, DESCR,PT,ON: 2 3 4 5 7 8 9 i DATE PERFORMED: SITE PLAN [] PERCOLATION TEST 10- 11 12 13- 14- 15- 16- 17- 18- 19- 20- WAS GROUND WATER y~ ENCOUNTERED? , '~ [~ O P ~F YES~ AT W~AT ~ DEPTR? Gross Net Depth to Net Reading Date Time Time Water Drop PERCOLATIQN RATE COMMENTS (minutes/inch) GRE/ FR ANCHORAGE AREA BOr 'JGH I~ll q l~ lll,)~l ~jrd~/ Department of Environmental Quality ~ 3330 C Street Anchorage, Alaska 99503 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM NAME LOCATION MAILING ADDRESS //~OX /-5'~/¢-~- 5 ~/":) OLd'PHONE LEGAL DESCRIPTION /Q7"'/,,¢ ~'/~"L / /~O$,/~''~7'"~ /'/~', SEPTIC TANK: DISTANCE FROM WELL ~'"~ INSIDE LENGTH MANUFACTURER NUMBER OF COMPARTMENTS INSIDE WIDTH ~ LIQUID DEPTH -- LIQUID CAPACITY ,/,'~',~'"~) GALLONS. NUMBER OF PITS ~ DIAMETER\. OR WIDTH ~_~__ LENGTH (~/¢, DEPTH r:¢~ LINING MATERIAL ~-- CRIB SIZE: DIAMETER '-'DEPTH -- DISTANCE FROM: WELL ~ .- BUILDING FOUNDATION //~¢-~'~, NEAREST LOT LINE //~/7~'' TOTAL EFFECTIVE ~* / · ABSORPTION AREA (WALL AREA) ~""~ ,~/'~"~JIQ. pr'.// ADDITIONAL ABSORPTION WELL: TYPE ~)~////z¢~ CONSTRUCTION BUILDING NEAREST FOUNDATION __ LOT LINE CESSPOOL OTHER SOURCES APPROVED DISAPPROVED NEAREST SEWER LINE REMARKS DEPTH SEPTIC TANK __ DISTANCE FROM: SEEPAGE ~ SYSTEM DISTANCES: INSTALLED BY: PIPE MATERIAL: LOT SLOPE: ~/~$ REMARKS: DIAGRAM OF SYSTEIV , N APPR OV ED ~.~_.~.~ ~¢::~ G.A.A.B. J ~ SEWAGE GReATEr ANCHOrAGe Area BOROUGH DEPARTMENT OF ENVIRONMENTAL QUALITY 3330 "C"STREET ANCHORAGE, ALASKA 99503 TELEPHONE 27/{-4561 PERMIT NO, DISPOSAL SYSTEM -- APPLICATION AND PERMIT NAME OFA.PL,CANT INSTALLATION LOCATION INSTALLATION OF: SEPTIC TANK TYPE AND SIZE OF FACILITY TO BE SERVED SEEPAGE PIT . DRAIN FIELD OTHER FINANCED THROUGH TO BE INSTALLED BY NOTE: THIS PERMIT IS NOT VALID WITHOUT SOIL TEST FINAL INSPECTION: 24 HOUR NOTICE REQUIRED. BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION BY THE DEPARTMENT OF ENVIRONMENTAL QUALITY AUTHORITY WILL BE SUBJECT TO PROSECUTION. MINIMUM DISTANCES, REQUIREMENTS FOUNDATION TO SEPTIC TANK SEPTIC TANK TO seePAge PIT WALl //~..~-- I . SEEPAGE PIT TO NEAREST LOT LINE. WELL TO SePt~C TANK--/~O' WATER MAIN TO SEPTIC T/~NK //~) I SEPTIC TANK, ? /~:~ , SEEPAGE PIT SEEPAGE PIt ALSO CONSIDER AREA WELLS, SEEPAGE Pit DRAIN FIELD CAST IRON INTO AND OUT OF SEPTIC TANK AND INTO CRIB CROSSING GAP OF EXCAVATION 5 FEET iNTO UNDISTURBED SOIL. 4 INCH DIAMETER CAST IRON SIPHON PIPES ON SEPTIC TANK AND SEEPAGE PIT FITTED WITH AIRTIGHT REMOVABLE CAPS. GRAVEL BACKFILL CONFORM TO BOROUGH REGULATIONS REGARDING INSTALLATION, TYPE DIAGRAM OF SYSTEM CERTIFY THAT ] AM FAMILIAR WITH THE REQUIREMENTS OF GREATER ANCHORAGE AREA BOR~H ORDINANCE NO. 28.68 AND THAT THE ABOVE DESCRIBED SYSTEM IS IN ACCORDANCE WITH SAID CODE. /.-'" DATE ~) ~ ~P~[ I~.a~t'~ ~P.~tH~ {~' GREATER ANCtlORt\GE AkEA BOROU, Department of Environmental Qua]i 3330 "C" S~reet Anchorage, A1 aska 99503 SOILS I,OG PEROI,A~[qON TEST Performed for ~il/~c~-¥~r]~- - A~oc~¥,c<~' ~~_ Date This form reports: Soils log Percolation test Depth Feet 1 - 2- 3- 4- 5- 6- 7- 9- lO- ll - 12- 13- 14- Was ground water encountered? If yes, at what depth? Reading Date Gross Time Net Time Depth to Water Net Urop minute. Percolation rate -Proposed 'installation: Seepa'ge Pit Drain Field Depth of Inlet .~ Depth to b~ttom of pit or trenci, Pe~'rm~:~b___~~ __ ~ert, fl ed By: Date: CONSULTING ENGINEERS & SUI vEYo · . ~ ~ ~ ~' i; ~ ................... j 103 E. 26TH AVE., ANCHORAGE 272-8911 .! Mr. Wayne Mabry Platting Officer Greater Anchorage Area Borough 3500 Tudor Road Anchorage, Alaska NElL WRIGHT .BUILDING, PALMER 74r~445~ February. 7, 1974 Re: Subdivision of Lot 14 Bk I Prospect Heights Subdlvlslon EATER ANCHORAGE AR~A BOI~OU~DI"I Dear Mr. Mabry~ We hereby request that the requlrem~nt for a soils,report be waived on the basis that adequate soils Information exlsts wlthln the exlstlng area. Discussions have been held with Mr. Roll Strlckland of D.E.Q. ~egard. l.ng solls information for this lot. Mr. Strlckland provlded Information on the lot across the street (Lot 14 Bk 2) which showed gravelly sand wlth a trace to some silt and cobbles. A rating of 85 was given for on-slte sewage whlch, corresponds to the general rating for the area. Our own experience based on a:test hole for Lot 19 Bk 2 indicated a rating of 125. A copy of this report Is enclosed for reference. ~ Based on these discussions and the. existing data It was felt that on-slte sewage wouldn't pose any problems. Also we have shown some proposed locations on the topographlc map for seepage plts and wells. These locations meet D.E.Q.!s criteria for separation and should enable a builder adequate room to 'Install an on-site sewage disposal system. Very truly yours, Gordon D. Unwln~ P,Eo Par, net GU/cs XC: Roll Strlckland, D.EoQo~/ Jack Jacobson GORDON D. UNWIN, P.E. LEO SCHEBEN~ JR.~ P.Eo Dry C Dry Fine TO'O' ~"~ PARTICLES RET. . % PASS ' e_¢, ¢ 4z¢,/ SPEC_ Lbs. °1o. °/~ X °1o , , ' R~f. Re.,'. Pass -No.4: A DRY ~,u_loN COARSE A-=omeGa. E Lbs. % % X% ,', Rat. R-~,. Foss. +No. 4:B TOTAL' Grad. A+B .O05mm I ,I. T 84 V,-'~T~h~ ¢ Flask WL ~ask W~er., Wl' -h~mp~T in E VTL Flask W.?.er SoiI~VY2 - WL of 'OW So'.:I,Ws SPECIFIC GRAVITY AND ABSORPTION T 85 COARSE AGGREGATE Weight SCuroted ' Welqht in Air, Dry Gain in 24 Hours Absorption,% V;eiqhl in Wafer Weight H~O Displaced s~. ~r. ( ) 200 '.~'cek Ccc'aa; r////Z////Y////: , t. ; t 7F ' ATTERBERG LIMITS D~sh No. Con No. WeimAr CGn+',Yef Soil Con+OW Soil V';e~oht of Woe, er Weiqht Con+Dry Soil '¢,'elqht of Can \;'e?ohl of DW ScH Mo[sl'dre,% LiQU;D LIMIT (LL) '. ( PLASTIC L_IMIT (PL) .- PLASTIC. INDEX (Pi) Clossif.;cofion Unifiad % +10- °/o Grcve] Sand % Sill Cloy AASH0 -*%2 GREATER ANCHORAGE AREA BOROUGH Department of Environmental Quality 3330 "C" Street, Anchorage, Alaska 99503 274-4561. Date Received o Time of Inspection Date of Inspection REQUEST FOR APPROVAL OF INDIVIDUAL SEWER & WATER FACILITIES FOR Mailin9 Address: / /) ~hhone: 2. Property Owner: o 4. 5. 6. Mailing Address: Legal Description:~/~?~ /~'/ Location: Type of facility to be inspected Phone: Well Data: A. C. Construction ~,~., Sewage Disposal System:~t~ A. Installed /~7~ C. Septic Tank: 1. Size No. of bedrooms B. Depth z//~/ D. Bacterial Analysis D. Seepage Pit: 1. Absorption Area B. Installer 2. Manufacturer E. Disposal Field: Total length of lines 2. Material 8. Distances: A. Well to: Septic tank Nearest lot line , Absorption area , Other contamination , Sewer Lines B. Foundation to septic tank , Absorption area C. Absorption area to nearest lot line EQ-034 (1/74) Page 1 of two paqes Page 2 of two pages - Re~ Legal Description for Approval of Individual St ~er & Water Facilities Comments ' Approved~t/~)~/~/~*~' /~ ,~2 Disapproved Date A'~broval Valid for one year from date signed Greater Anchorage Area Borough, Department of Environmental Quality DIAGRAM OF SYSTEM certify that the information contained in this request for approval to be a true and accurate representation of the subject sewer and water facilities and these facilities are operating satisfactorily. SIGNED Date EQ-034 (1/74) GRcAI .K ANCHORAGE '~:' r,R~,~ BOROUGH Department of Environmental Quality 3320 "C" St., Anchorage, Alaska 99503 - 274-4561 REQUEST FOR APPROVAL OF INDIVIDUAL SEWER & WATER FACiLITiES 1. Type of Inspection: CM,~O VA ~.. FHA CONV 2. Property Owner: ~.</ ~ ~ '[~C'~? · ' Mailing Address: , 3. Name of Buyer: Mailing Address: Day Phone Na~e of Realtor or Agent: Mailing Address: Phone Legal Description:' .~_~[~ ' zv ". c .... .._ ' ' I~ '- ' . ' . - .Type oF Facility ~o be ~nsgected: / No. Bdrms. _~ . Water Supply Type of Supply: Public Utility individual If Individual, number of dwellings presently .served if individual~ depth of well ~..~_ ' Sewage Disposal'System Type.of S~stem: Public Utility If Individual, date of installation' individual (on-site) ___ 1975 Lawrence Sebring S,R.A, Br~: 1540 C Anchorage, Alaska 99507 SU}~JECT: He~lth approval of Lot 14. Block I, Pro~poet lleights Subdivision De~r Mr, S~bring: The water on the ~ubjeet p~'operty e~nnot bo an~yzod duo to no pump installation 'i'he sewer system on the subject lot is approved by this Depnrtmen! for a four- bedroom, single family clwol!ing. The w,~ll is the required di.~tnnoe t¥om the sower system. At this time, it is not feasible to establish public sower to serve this lot. if you have ~ny questions, ple~e feel free to contact me at 274-4561, oxten~ion 135. Sinc~roly, Les Buohholz, R.S,, Sanitarian LB/ko cc: Kassler ~ Co, Veteran'~ Admhltstrati~11 78g70 v Co 1 Municipality of Anchorage Cr ,, On-Site Water and Wastewater Program i • (907) 343-7904 .�E T i 3 4 Certificate of On-Site Systems Approval `i ac•›"68t. Parcel I.D. 015-091-05 Expiration Date: Jci4 4 2 D i I 1. GENERAL INFORMATION Complete legal description Prospect Heights Block 1 Lot 14 Location (site address) 9601 Prospect Drive Current Property owner(s) Plooy Warehouse, LLC Day phone Mailing address 4920 Sportsman Dr. Anchorage, AK 99502 Real Estate Agent Day phone 2. TYPE OF DWELLING: 0 Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 4 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well E Individual 0 Individual Water Storage ❑ Holding Tank ❑ Community Class Well ❑ Community ❑ Public Water System ❑ Public Sewer ❑ WaiverNariance request for: Distance: ----- , ir Received b : ti la,..1h ...`. Date: 1240 COSA to be released to the engineer,unless otherwise request-• he engineer. COSA Fee $ 52( — Waiver Fee $ Date of Payment 1-1--2-° "�B Date of Payment Receipt Number Gil(c3(-x Receipt Number COSA# 05W ll 6(e' Waiver# 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater • disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances,and regulations in effect at the time of installation. In conducting an adequacy test,I attempt to provide a thorough,conscientious engineering analysis of the system in accordance with MoA COSA guidelines and regulations.The reported results describe the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readily identifiable features. The operational life of all wells and septic systems depend on the local soil condition,ground water levels that may fluctuate during the year,and the water usage of the family being served by the system.These conditions are outside the control of the evaluator of this system. All systems eventually fail and satisfactory test results do not guarantee future performance of the system,nor do they guarantee that there are no hidden defects or encroachments.Therefore we cannot provide any warranty for future performance, nor can we estimate remaining life of the system. The content of this report is for the sole benefit of the owner listed above. Name of Firm Pannone Engineering Services LLC Phone (907) 272-8218 Address P.O. Box 100217, Anchorage Ak. 99510 Engineer's Printed Name Steven R Pannone Date 4/19/2018 OFA \ co.-": T,-, i� •*fl 6. DSD SIGNATURE / • .� System#1 Approved for /4 bedrooms •Steven R. annone:•' �,•. CE-8149 ., -/ System #2 Approved for bedrooms 9 �s'•, •' � Disapproved 1'k''?S`\ \N Conditional approval for bedrooms, with the following stipulations: �\ �� OOF AA/r, ON-Sl TE ��,. z WATER AND WASTEWATER o• `% pROGRAM • 2 '4/)4; •Ari.07.a�l���c By: -Pa's-et,c6/zi-r-e—P Original Certificate Date: V2 I 2 0 1 g The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On-Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA blue sheet_S If more than 1 septic system is on the lot: COSA Checklist# 1 of 1 Structure served by this system 1 Certificate of On-Site Systems Approval Checklist Legal Description: Prospect Heights Block 1 Lot 14 Parcel ID: 015-091-05 A. WELL DATA Well type Private If A, B, or C provide PWSID# Well Log (Y/N) N Date completed UNK Sanitary seal (Y/N) Y Wires properly protected (Y/N) Y Total depth '120+/ ft. Cased to *25 ft. Casing height (above ground) 12+ in. FROM WELL LOG AT INSPECTION Date of test UNK 4/10/2018 Static water level UNK ft32.4 ft. Well production UNK gpm 1.4 g p m WATER SAMPLE RESULTS: Coliform NEG colonies/100 mL Nitrate 1.13 mg/L Arsenic ND ug/L Date of sample: 4/10/2018 Collected by: PES B. SEPTIC/HOLDING TANK DATA Tank Type/Material Septic/Steel Date installed 10/28/2005 Tank size 1250 gal. Number of Compartments 2 Cleanouts(Y/N) Y Foundation cleanout I/(Y/N) Y Depression over tank(Y/N) N High water alarm (Y/N) N/A Date of pumping ' 2 0'I Pumper /4 4- C. ABSORPTION FIELD DATA Date installed 7/15/1982 Soil rating2 2 183 SQFT/BDRM TRENCH (g.p.d./ft or ft /bdrm) System type Length 149 ft. Width 5 ft. Gravel below pipe 0.5 ft. Total depth ..3.0+ ft. Eff. absorption area 732+ft2 Monitoring tube Y Depression over field N Date of adequacy test 4/10/2018 Results(Pass/Fail) PASS For 4 bedrooms Fluid depth in absorption field before test 0 in. Water added 600 gal. New depth 0 in. Elapsed Time: 60 min. Final fluid depth 0 in. Absorption rate >= 600+ g.p.d. N Any rejuvenation treatment(past 12 mo.) (Y/N &type) If yes, give date D. LIFT STATION Date installed Size in gallons Manhole/Access (Y/N) "Pump on" level at in. "Pump off' level at in. High water alarm level at in. Datum Cycles tested Meets alarm&circuit requirements? E. SEPARATION DISTANCES WELL ON LOT TO: Septic tank/lift station on lot 100+ On adjacent lots 100+ Absorption field on lot 100+ On adjacent lots 100+ Public sewer main 75+ Public sewer manhole/cleanout 100+ Sewer/septic service line 25+ Holding tank 100+ Animal containment areas 50+ Manure/animal excrete storage areas 100+ SEPTIC/HOLDING TANK ON LOT TO: Building foundation 10+ Property line 10+ Absorption field 5+ Water main 10+ Water service line 10+ Surface water 100+ Wells on adjacent lots 100+ ABSORPTION FIELD ON LOT TO: Property line 10+ Building foundation 10+ Water main 10+ Water Service line 10+ Surface water 100+ Driveway, parking/vehicle storage 10+ Curtain drain 50+ Wells on adjacent lots 100+ F. COMMENTS *Per Arrow & Pump Well service report from 2011 . **Drainfield is insulated. Survey on file. b- OF AL kk G. ENGINEER'S CERTIFICATION ��� � / certify that / have determined through field inspections and ..wed:.' �4,,.•1y4, review of Municipal records that the above systems are in 0*: 4 L` /' *9 conformance with MOA COSA guidelines in effect on this date. _�; .,) ' Engineer's Printed Name Steven Pannone ,": }everi IV'anriarie: Date 4/19/2018 111 �1g.• CE-8149 a .•r COSA canary sheet_2-6-15.doc Municipality of Anchorage Development Services Department Building Safety Division On-Site Water & Wastewater Program 4700 Elmore Road P.O. Box 196650 Anchorage, AK 99519-6650 ,~ ~i~ · www.muni.org/onsite ~.,~"'~f" (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEHS APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. 01 5-091-05 1. GENERAL INFORMATION COSA# (~--7~--%(% \ / \ q Li ~- Complete legal description Location (site address) Current Property owner(s) Mailing address Lending agency Mailing address Real Estate Agent Mailing address PROSPECT HEIGHTS SUBDIVISION; BLOCK 1, LOT 14- 9601 PROSPECT DRIVE * ANCHORAGE, AK 99516 DAVID AND BONNIE ALEXANDER Day phone 9601 PROSPECT DRIVE * ANCHORAGE, AK 99516 Day phone DAR WALDEN W/KELLER WILLIAMS Day phone 865-6406 Unless otherwise requested, COSA will be held by DSD for pickup. 2. NUMBER OF BEDROOMS: 31' 'TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: "' · Individual On-site Individual Well Individ~jal Water Storage [] Individual Holding tank CommunitY Class Well [] Community On-site PubliC Water System [] Public Sewer The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of On-Site Systems Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of On-Site Systems Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues COSAs upon request to homeowners. Certificates of On-Site Systems Approval are valid for 90 days from the date of issue for properties served by a private'or Class C well and may be reissued with new water samples. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with afl applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm GARNESS ENGINEERING GROUP, Ltd. Phone 3,37-6179 Address 3701 E. TUDOR ROAD, SUITE 101 * ANCHORAGE, AK 99507 Engineer's Printed Name JEFFREY A. GARNESS, P.E. Date Engineer's Comments: In conducting this evaluation, GEG, LtD. attempted to provide a thorough, conscientious engineering analysis of the system in accordance with ADEC and MOA DSD Guidelines & Regulations. The reported results described the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readily identifiable features. The operational life of all wells and septic systems depend on the local soils condition, groundwater levels that may fluctuate during the year, and the water usage of the family being served by the system. These conditions are outside the control of the evaluator of the system. Satisfactory test results do not guarantee future performance of the system, nor do they guarantee that there are no hidden defects or encroachments. GEG, LTD. can therefore not provide ...any warranty or future estimate of how long the system will continue to meet the operational requirements'of the ADEC or MOA DSD. The content of this report is for the sole benefit of the owner listed above. Any reliance upon or use of this report by any other person or party is not authorized, nor will it confer any legal fight whatsoever. DSD SIGNATURE Approved for bedrooms· 'Attachments: COSA Checklist Disapproved. Conditional approval for bedrooms, with the fo~ow~ng supu,auons:,, .. ,:. .. pRO "' , '.. .. ~, ~-!~ _~ ~_ ~ Septic System Advisory Well ~ow Advisory~ Nitr~}~ Advisory/:: ,/'/ .,::; // // Arsenic Advisory Maintenance Agreements Supplemental Engineer's Report Other Original Certificate Date: (Rev. 11/05) Municipality of Anchorage Development Services Department Building Safety Division On-Site Water & Wastewater Program 4700 EImore Road P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST LegaI DescFiption: PROSPECT HEIGHTS SUBDIVISION; BLOCK 1, LOT 14 ParoelID: 015-091-05 *SEE A~-I-ACHED DOCUMENTATION FROM **PER GE(:; FIELD MEASUREMENTS. IfA, B, orC provide PWSID# N/A A. WELL DATA Well type PRIVATE Date completed UNK · Total depth *'124+ff. Sanitary seal (Y/N), YES Cased to FROM WELL LOG NO WELL LOG AAROW PUMP & WELL SERVICES. Well Log (Y/N) YES Wires properly protected (Y/N) *22 .ft. Casing height (above ground) AT INSPECTION 1 /7/11 .ft. 28 ft. g.p.m. 0.74 g.p.m. Nitrate~- '~¢'mg./L. Collected by: GE(;, Ltd. Date of test Static water level Well production Date of sample: 11/4/11 WATER SAMPLE RESULTS: Coliform O colonies/100 mi. Arsenic: ~___j~ug./L. B, SEPTIC/HOLDING TANK DATA Tank Type/Material SEPTIC/S'I:EEL .Tank size 1250 gal. Number of Compartments __ Foundation cleanout (Y/N) YES Date of pumping 11/11/11 C. ABSORPTION FIELD DATA Date installed 7/15/82 Length 149 ft. 2 Depression over tank (Y/N) NO Pumper. [*BELOW EXISTING GRADEJ Soil rating (g.p.d./fFor~ 183 Width 5 ft. YES 24-+ in. Water added 500 gal. Date installed 10/28/05 Cleanouts (Y/N) YES High water alarm (Y/N) N/A ONE STOP SERVICES System type Gravel below pipe Total depth **'3.0+ ft. Eft. absorption area 732+ ft2 Monitoring tube YES Date of adequacy test *'11/5/11 Results (Pass/Fail) PASS Fluid depth in absorption field before test 0 in. Elapsed Time: 0 min. Final fluid depth 0 Any rejuvenation treatment (past 12 mo.) (YIN & type) **TRENCH WAS PRE-SOAKED ON 11/2/11 WITH ***DRAINFIELD IS INSULATED. TRENCH 0.5 ft. Depression over field NO For 4- bedrooms New depth 0 in. in. Absorption rate >-- 650+ g.p.d. NONE KNOWN If yes, give date - 2000 GALLONS OF WATER. D. LIFT STATION Date installed 'Pump on" level at ~ ~ Cycles tested E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot 100' + Size in gallons Manhole/Access ~ ~ gh water alarm level at in. Meets alarm & circuit requirements? 100'+ Absorption field on lot Public sewer main N/A Sewer/septic service line 25'+ Animal containment areas *35' On adjacent lots 100'+ On adjacent lots 100'+ Public sewer manhole/cleanout Holding tank N/A Building foundation Water main Wells on adjacent lots N/A Manure/animal excrete storage areas SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: 5, + Property line 5' + Absorption field N/A Water service line 10'+ Surface water 100'+ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line 10'+ Building foundation 10'+ Water service line 10'+ Surface water 100'+ Curtain drain NONE KNOWN Wells on adjacent lots 100'+ 5'+ 100'+ Water main N/A Driveway, parking/vehicle storage 100~+ 10'+ F. COMMENTS *APPEARS TO BE AN OLD HORSE CORRAL BUT DOES NOT CURRENTLY HOUSE ANY A/~ALS. ..... G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. Engineer's Printed Name JEFFREY A. GARNESS Date ,,I,~/I, cos^ s q Date of Payment Receipt Number (Rev. 11/~) Waiver Fee $ Date of Payment Receipt Number / / / / / ,/ I HEREBY CERTIFY ~AT I HAVE PERFORMED A SURVEY OF THE FOLLOWING DESCRIBED PROPERTY LOT 14j BLOCK 2j PROSPECT HEZGHTS SUB. ANCHORAGE RECORDING DZSTRZCT~ ALASKA~ AND THAT THE GARNESS ENGINEERING GROUP, Ltd. CONSULTANTS & GENERAL CONTRACTORS November 17, 2011 Municipality of Anchorage Development Services Department On-Site Water and Wastewater Program P.O. Box 196650 Anchorage, Alska 99519-6650 Attn: Jay Crewdson, P.E. Ref: Prospect Heights Subdivision, Block 1, Lot 14 - Septic System Adequacy Test. Mr. Crewdson: As we discussed via phone today, on 11/2/2011 we presoaked the drainfield on the subject property with 2000 gallons of water (delivered in 500 gallon loads) and it remained dry throughout the test. On 11/3/2011, an additional 500 gallons was introduced into the drainfield, and it remained dry. Based upon this data, the drainfield absorption capacity was deemed to be greater than 600 gallons per day. If you have any questions, please call me at 337-6719. Best Regards, Jeffrey A. Gamess, P.E., M.S. President 3701 E. Tudor Road, Suite 101 * Anchorage, AK 99507 Ph: (907) 337-6179 * Fax: (907) 338-3246 * Website: gamessengineering.com MUNICIPALITY OF ANCHORAGE Community Development Department Development Services Division On-Site Water & Wastewater Program Phone: 907-343-7904 Fax: 907-343-7997 Mayor Dan Sullivan 11/17/11 Prospect Heights Subd., Block 1, Lot 14 COSA: OSC111445 The trench was approved in 1982 at 149 feet (see inspection report). The 2005 septic tank upgrade permit and inspection report appear to be drawn incorrectly and do not agree with the approved 1982 installation. The 1987 septic tank upgrade inspection report shows swing-tie dimension arrows that could be mistaken for the location of the drainfield. The important point to notice on the 1987 report is the 27 feet of pipe replaced as noted in the remarks. That section of pipe is likely leading to the current drainfield which was installed in 1982. The drainfield was approved in 1982 with a total depth of 2 feet. The current COSA shows 3 feet from existing grade, which is assumed to be due to subsequent landscaping after the drainfield was originally installed. On-site OM. ;Rlpin~ Dr'illin9 Aa~o~v FRX NO. :~07 345 0202 Pump & Well Service, LLC P.O. Box 110496 Anchorage, AK 99511 (907) 346-9,~5 · Fa× (907)3s~-897~ ~-TT~/ Nov. 07 2011 09:23RM P1 No. 9184 F CUSTOMER ., ;,'....,.:,.: .. ...... .. '.. DESCRIPTION .. ' ..... :, '" ',:'.,":-;. ,::' ::". ". ,. ":' ~;,;i':3P!~ .... ~.~:.~e~', ~.'!.~,';,~"'" ~ .... ' ,' , ................ × ., .. -l,Ti Wmm ~R .~ HOU~ RATE AMOUNT , 8 '~ ruc~. TOTAL MATERIAL Thank You SIGNATURE (I Hereby Acknowledge ~ Satiefactory Completion of the Above Described Work and agree that H above work is not paid for in 90 days I agree tO allow Aarow ' Pump & Well Service, LL.C. the dght to remove unpaid for equipment and charge fo~ labor already performed & labor to remove unpaid for equipment.) . TERMS: ACCOUNT8 PAYABLE AT 10TH OF MONTH FOLLOWING PURCHASE. Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700 Elmore Street P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 Water Well Advisory Certificate of On-Site Systems Approval (COSA) # OSC111445 During a recent COSA on-site inspection and test of the potable water supply well on Block 1, Lot 14 of Prospect Heights subdivision, the well's productivity was determined to be 0.74 gallons per minute. The minimum well productivity required by this Department (AMC 15.55) for a 4-bedroom residence is 0.42 gallons per minute. Although the subject well currently exceeds this minimum requirement, all parties concerned are advised that the production capacity of the well may fluctuate. Restriction of non-critical water uses such as washing cars and watering lawns and gardens may be required. This advisory must be attached to all copies of the subject Certificate of On- Site Systems Approval.