Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PROSPECT HEIGHTS BLK 2 LT 11
Municipality of Anchorage page _ I _of ~. DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744 On-Site Wastewater Disposal System and/or Well Inspection Report Wastewater System: D New ~pgrade Address: ~q~ ~Og~O~ ~[¢~ ABSORPTION FIELD Phone: IN°'°f~e~°ms: ~DeepTrench ~ Shallow Trench ~ Bed ~ Mound ~ Other LEGAL DESCRIPTION s°""~""~: O. ~ GPD/Sq. Ft- T°lalDepthfr°~°~nalgrade: ,.. Gravel deplh beneath pipe Lot: Block: Subdivisions. Depth to pipe bottom Irom o~na[ grade: ~ Ft. TOWnShip: IRange: IsectiOn: Fill added above original, fade: Gravel ~9t~ ~-- ~ Ft. Number of lines: ~Distance between WELL: D New D Upgrade ~ FL, Classification (Private, A,B,C): Total Depth: C~sed TO: Tolal ~bsorpfion area: Pipe maleriah Yield: ~ P.mp Set at: Casing Heigh, Above Ground: TAN K GPM Ft. Ft. SEPARATION DISTANCES ~Septic U Holding U S.T,E.P. Capacity in gallons: TO Septic Absorplion Lgt Holding Public/Private From Tank Field Station Tank S ..... Lines ~ 'T~ I ~ I ~ Material: ~ ~ Number Of Co~ents: Well I10 lSD Surface ~ LIFT STATION "" Size in gallons: ~Manufacturer: Lot ~O ~ O "Pump off" ~ High water alarm at: Line "Pump on" level at: ~ level at: Foundation ~¢ Pump Make & Model Electrical Inspections performed by: Drain ~ BENCH MARK Remarks: ~~ Location and Description~ ~ ¢~ 5 Inspections performed by: % ¢ Dates:~~ ~' Department of H h and ,c ~ rvi[es approval ' ~?'~;~",, ~' '~' "' NOTE: / / / THIS IS NOT A SURVEYED A / IMPROVEMENTS LOCATED RAG/TAPE BC 58 // / BD 58 / AE 45 / / / 25 BE 52 / / / BF 58.5 / AG 45 BG 47 / AH 85 / BH 84 / / / / ii/iI I I I I I / / ii//i I / / / / / / 10 FEET DEEP 6 FEET OF ROCK SCALE: ]' = 50 FT, FND. ,~2+EANOUT + + MA~R~% TOP GARAGE SLAB NEW 1250 GAL 2 TRENCHES 45 FEET LONG +++ 203 W 15TH. AVENUE ANCH. AK. 99501 (907) Z79--~916 11, BLOCK 2 PROSPECT HEIGHTS NO£ER~ HORRELL 9950 PROSPE£1- DRIVE 125 I I SEPTIC SYSTEM AS BUILT DATE: AUGUS[ 2, 1995 SHEET: I/$ GRID: 2441 Mon/tor 4S Cleon itu Stondord Trenches; 2' Vide 45' Lon9 lO' Deep 6.0' Smwer rook 3' Cover solid pipe cross connect /4 Cleon Cleon But 11~50 90{ Septic tank ~]VE£TE£ VALVE BULL RUN NO SCALE NOTE: BOTH ?NENCHES INSTALZED AT SAME ELEVAtiON 94.0 Mir'o Pi 140 87.4 6 Pt oP Septic Rock UNDER PIPE Mon/tom 3' Cover ~ 00~ 87.~ ' Min Cover Tonk 96.0 1~0 9al. septic tank BENCH MARK, ~A£A6E FLZ2[I~ ASSUMEB ELEV. 100.00 TB]}}~EN SPURKLAN]] P,E. 803 WlSth Ave Anchomoge Ak 99501 777-~16 I ILDT LD£K £ P£DSPEST HE/dHTS BDBHD~ELL 99SOP~DSPECT DRIVE IISEPTIC SYSTEM AS BUILT SHEET, 3/3 GRID: MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND HUMAN SERVICES P.O. BOX 196650, 825 "L" STREET, ROOM 502 ANCHORAGE, ALASKA 99519-6650 ON-SITE WASTEWATER DISPOSAL SYSTEM (UPGRADE) PERMIT PERMIT NUMBER:SW950161 DESIGN ENGINEER:TOBBEN SPURKLAND, P.E. OWNER NAME:HORRELL SHIRLEY & ROBERT D OWNER ADDRESS:9950 PROSPECT DR ANCHORAGE, AK 99516 PAGE 1 OF 1 PARCEL ID:01509115 DATE ISSUED: 7/15/95 EXPIRATION DATE: 7/15/96 LEGAL DESCRIPTION: PROSPECT HEIGHTS BLK 2 LT 11 LOT SIZE: 90072 (SQ. FT.) NUMBER OF BEDROOMS: 4 THIS PERMIT: THIS PERMIT IS FOR THE.CONTRUCTION OF: DISPOSAL FIELD /SEPTIC TANK SYSTEM ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH: 1. THE ATTACHED APPROVED DESIGN. 2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS 15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (iSAACS0) . 3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY CALLING 343-4744 ( 24 HOURS ) (NOT REQUIRED FOR WELL ONLY PERMIT) 4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING WEATHER MUST BE EITHER: A. OPENED AND CLOSED ON THE SAME DAY B. COVERED, SEALED AND HEATED TO PREVENT FREEZING 5. THE FOLLOWING SPECIAL PROVISIONS. SPECIAL PROVISIONS: RECEIVED BY: ~ --~ ISSUED BY: ~~ DATE: DATE: T.SPURKLAND P.E. 203 W 15th. Avenue, Suite 203 ANCHORAGE, ALASKA 99501 (907) 279-3916 Fax (907)-276-6013 SEPTIC SYSTEM DESIGN LOT 11 BLOCK 2 PROSPECT HEIGHTS #1 BOB HORRELL No Ground Water or Impervious Layer to 16 fi. Use Standard Trench Soil Rating. From test June 1, 1995 20 min/in = 0.6 gal/sq, fi. No. of Bedrooms 4 Required Area per Bedroom: 150/.6 = 250 sq.fi.. Total area required: 4x250 = 1000 sq. fi. Existing tank 7.5 feet deep. Liquid depth 5 feet Ground Elevation 99.6 Tank outlet elev. 97+- Finish Floor Elevation 100.00 Ground Elevation at Absorption Field 100 +- Testhole Total Depth 16 Ft. Less 6 feet 10 Less 4 feet Cover 6 Rock Depth 6 Ft. Length of Trench 1000/2 x 6 = 83.3 [FT.] Use 2 trenches at 45 feet each SYSTEM CONFIGURATION STANDARD TRENCH TOTAL LENGTH 90 FT. TOTAL WIDTH 2 FT. ~ TOTAL DEPTH 10 FT/ ROCK DEPTH 6 FT. COVER 4 FT. -f SEPTIC TANK 1250 GAL. ABANDON EXISTING SYSTEM The installation of this septic system will not prevent wells from be installed on the adjacent lots. Them are no developed or natural surface / sub surface drainage courses on this or the adjacent lots. The proposed septic system will not change the general slope of the area. PondJng and/or concentration of surface mnoffwill not result from this installation. MUNICIPALITY OF ANCHORAGI~ I:NVIRONMENTAL SERVICES DIVISION .., ~L !I 1995 RECEIVED LEGAL DESCRIPTION: 1 2 3 (~?/'W~' 6 ,8 12 17 19 20 Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST .'-: (ENGINEER'S SEAL) Township, Range, Section: WAS GROUND WATER ENCOUNTERED? SLOPE SITE PLAN S L IF YES, AT WHAT 0 DEPTH? p E Depth to Water AfteE ... --.-'1/./. Monitoring? t~-) ~'~ Date: Gross Net. Depth to Net Reading Date Time Time Water Drop 7° I~;~s 16 ~ o ~/y PERCOLATION RATE ,'~(~ (minutes/inch) PERC HOLE DIAMETER TEST RUN BETWEEN ~:~ FT AND ~-~ /~- FT COMMENTS PERFORMED BY: ~ ~ I ~ ~ CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUN,C,PAL GU,DEL,NES ,N EFFECT ON THIS DATE. DATE: '~"z"~'b ~a1 72-008 (Rev. 4/85) ~th LOT !0 c~ $00 Lt/T 11 ITOBBEN SPURKLAND P.E. [ILOT 205 W 15TH, AVENUE ANCH. AK. 99501 (9o7~ 279-~916 11, BLOCK 2 PROSPECT HEIGHTS ROBERT HORRELL 9950 PROSPECT DRIVE I I SEPTIC SYSTEM DESIGN DATE: JULY 6, 1995 SHEET: 1/$ GRID: 2441 NOTE: / / / / / THIS IS NOT A SURVEYED AS/BU~T.// IMPROVEMENTS LOCATED fly PE / / / / / / /~/~x.~ , I I I I I / / / / / / / / / / / / /~/ / / ~ I ii I I I I II I / II I I II NEW 1250 GAL SEP~ 2 TRENCHES 45 FEET LONG 10 FEET DEEP 6 FEET OF ROCK TOBBEN SPURKLAND P.E. I I£oT II 205 W 15TH. AVENUE ANCH. AK. 99501 (907l 2S SO 7~ SCALE: 1'~ - 5~ FL N FND. ~ANOUT *' ~C+. TANK * / / 11, BLOCK 2 PROSPECT HEIGHTS//1 ROBER~ HORRELL 9950 PROSPECT DRIVE SEPTIC SYSTEM DESIGN DATE: JULY 6, 1995 SHEET: 1/3 GRID: 2441 Monitor 45 Cleon Standard Trenches: k/ide 45' Lan9 Bemp ]4 ~ Se~/er rock Cover solid pipe cross connect Monitor Clean Cleon Out '25~ 9°VE] STE]P tilL t~°V~k ~UL L -RUN Mira Fi 140 6 £~ o£ Septic /~ock UNDE[~ PIPE ND SCALE Clmonouts 4" Topsoil 3' Cover ND SCALE Monitor Exist, Ground 4' M/n Cover BENCH MAt~K, 6At'AGE FLOOR ASSUMED ELEV, 100,00 TOBBEN SPURKLANB P,E, 203 W15th Ave Anchopage Ak 99501 LOT H ~Lg£K £ P£DSPE£T HEIGHTS BOB HDRR£LL 9950 PROSPECT DRIVE SEPTIC SYSTEM AS BUILT DATE, JUL Y SHEET, 3/3 GRID: £441 MUNICIPALITY Development Services Department On -Site Water & Wastewater Section Certificate of On -Site Systems Approval Parcel I.D. 015-091-15 1 Phone: 907-343-7904 Fax: 907-343-7997 Expiration Date: 10 —1 � r7=� GENERAL INFORMATION Complete legal description Prospect Heights Sub, B2 L11 Location (site address) 9950 Prospect Dr, Anchorage, AK 99516 Current property owner(s) John & Rachel Botson Day phone (907)350-3249 Mailing address 9950 Prospect Dr, Anchorage, AK 99516 Real estate agent Margie H u d o k Day phone (907) 748-3656 2. TYPE OF DWELLING: ❑■ Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 4 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Private Well ❑Q Private Septic ❑■ Water Storage ❑ Holding Tank ❑ Community Well ❑ Community ❑ Public Water System ❑ Public Sewer ❑ Waiver request for: Distance: Received by: COSA to be released to the engineer, unless otherwise requested by the engineer. COSA Fee $ E5 5o Date of Payment TA I Receipt Number. b3r�'30 COSA# CSC ), 11 3 '11 Date: Waiver Fee $ Date of Payment Receipt Number Waiver # 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is (are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. I acknowledge that On -Site staff may visit the site to verify the information submitted. Name of Firm Forge Engineering Phone (907) 522-7773 Address 1399 W. 34th Ave Suite 101, Anchorage, AK 99503 Engineer's Printed Name Benjamin Schiller Date 7/12/2021 ,r � OF A�q�ll1 TTH *fir 6. DSD SIGNATURE 4.. ,��!:�-- System #1 Approved for bedrooms ' Benjam�rVSchiller System #2 Approved for bedrooms �� `��isl . �iEzizozi Disapproved �,k1k, PROfESS10N1`��� Conditional approval for bedrooms, with the following stipulations: z ON"S1�E r WPB r�tP�ER o n-r ?10 GIN �r cGc� 1))))))lll��, i Original Certificate Date: 7 The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Septic System Advisory Well Flow Advisory COSA Checklist blue sheet Nitrate Advisory /' Arsenic Advisory Other _c, CG- (7ov. /�"ary i� Legal Description: Prospect Heights Sub B2 L11 If more than 1 septic system on lot: COSA Checklist # of A. WELL DATA ❑ Well log is filed with Onsite (or attached) Date drilled 1967 Total depth 130 ft Cased to 40 ft 0 Sanitary seal is functioning correctly © Wires are properly protected Casing height (above ground) 15 in. Date of flow test for COSA 6/29/21 Static water level at beginning of test 40.8 ft. Comments No well log- well camera'd on 6/25/07 B. TANK DATA Age of tank(s) 25 years Tank type/material Septic/Steel Measured operating fluid level in septic tank 0* W Standpipes/foundation cleanout per record drawing Date of pumping 6/25/21 McDonald's Pumping Service D. ABSORPTION FIELD DATA Deep Trench Which system tested (date installed) 7/20/95 W ALL standpipes present per record drawing Total measured depth from grade 11 '4"1'' ft (max) Measured depth to pipe invert from grade 5.6/5.6 ft (min) ❑ N/A — pressurized field © Monitor tubes go to bottom of effective. If not, state depth into effective © Code -required soil cover over field 7 System presoaked (Required if vacant for greater than 30 days prior to date of test) 2000 Gallons introduced gallons Comments/Deficiencies: •• Fluid levels are post pre-soak. COSA Checklist yellow sheet Parcel ID: 015-091-15 Structure served by this system Well production at time of test 1.0 gpm Water storage tank volume gallons Well disinfected for coliform test? ❑ Yes ❑ No ❑ Coliform bacteria is Negative Nitrate 9.59 mg/L ❑ Nitrate less than MRL (ND) Arsenic ug/L ❑ Arsenic less than MRL (ND) Collected by Forge Engineering Date of Sample 7/1/21 FT STATION ❑ Requlr aint, Age of lift station Lift station material Comments: ce completed years Adequacy test date 7/6/21 Results 0 Pass For 4 bedrooms Fluid depth prior to test 69/59" in Water added 725 gal New depth 64/73 in Elapsed time 1440 min Final fluid depth 35/36 in Absorption rate '600 gpd Any rejuvenation treatment (past 12 months) If yes, enter date E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well) Septic Tank/Lift Station on Lot > 100' ❑✓ Yes Community Sewer Manhole/Cleanout > 100' ✓Q Yes if No ft 2] Yes if No ft Neighboring Tank > 100' 0 Yes if No ft Private Sewer/Septic Line > 25' 0 Yes if No ft Absorption Field on Lot > 100' F/� Yes if No ft Holding Tank > 100' P/1 Yes if No ft Neighboring Absorption Fields > 100' Q Yes if No ft Water Main > 10' Animal Containment > 50' 0 Yes if No ft M Yes if No ft r7l Yes if No ft Water Service Line > 10' 0 Yes if No Manure/Animal Excreta Storage > 100' If septic tank is under driveway comment below Community Sewer Main > 75' 0 Yes if No ft El Yes if No ft From Septic/Holding Tank on Lot to: (Please enter distances if less than required) Building Foundations > 10' ❑✓ Yes if No ft Surface Water > 100' Q Yes if No ft Property Line > 5' F,71 Yes if No ft Wells on Adjacent Lots: El Absorption Field > 5' 0 Yes if No ft Private Wells > 100' Q Yes if No ft Water Main > 10' FV -1 Yes if No ft Community Wells > 200' r7l Yes if No ft Water Service Line > 10' 0 Yes if No ft If septic tank is under driveway comment below From Absorption Field on Lot to: (Please enter distances if less than required) Building Foundation > 10' ®✓ Yes if No ft If absorption field is under driveway comment below Property Line > 10' F,71 Yes if No ft Wells on Adjacent Lots: Water Main > 10' El Yes if No ft Private Wells > 100' ®✓ Yes if No Water Service Line > 10' El Yes if No ft Community Wells > 200' Yes if No Surface Water > 100' 0 Yes if No ft F. ENGINEER'S COMMENTS * Home vacant and septic tank pumped four days prior to testing. OF G. ENGINEER'S CERTIFICATION 4�AQ I certify that 1 have determined through field inspections and review IM•����� of Municipal records that the above systems are in conformance with � MOA COSA guidelines in effect on this date. Benj amrf,chiller CE 12592 •���`��� 7/12/2021, • �,®. COSA Checklist yellow sheet ft ft MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT � On-site Water and Wastewater Section, www.muni.org/onsite Septic 'Tank Advisory Certificate of On -Site Systems Approval #OSC211391 Subdivision: prospect Heights B2 Lot 11 WMEMEM TV Ell M M. Starting at 20 years of age the MOA issues Advisory's for steel septic tanks. The septic tank for this property is 25 years old. Typical replacement costs range from $8,000 to $11,000 This advisory must be attached to all copies of the subject Certificate of On -Site Systems Approval. This is an example of what the metal of a 20 -year-old steel tank MAY look like. Nlail�rig Address P O Box 196650s* Anchorage,'Alaska 99519 6650 wwwAunh org Nitrate Advisory Certificate of On -Site Systems Approval # OSC 211391 Subdivision: Prospect Heights B2 Lot 11 A water sample revealed a nitrate concentration of 9.59 milligrams per liter (mg/Q. The Environmental Protection Agency (EPA) has established a maximum contaminant level (MCL) of 10.0 mg/L for public drinking water systems. While private wells are not subject to this regulation, EPA standards are based on existing health information and can therefore be used to gauge the relative quality of water from private wells. Please see the attached "Nitrate Fact Sheet" for important information regarding nitrate. This advisory must be attached to all copies of the subject Certificate of On -Site Systems Approval. 3 Rst"". a's ,.,y.. '. Ma�lirig Address P O Box 196650 *Anchorage, Alaska 99519 i6650 *www morn org MIN From Northern Testing Laboratories, Inc. Nitrate is a negatively charged compound of nitrogen and oxygen, which is very soluble in water. Nitrate is not readily filtered or otherwise removed in the soil and can pass rapidly into ground water wells. SOURCE: Nitrate is a major component of fertilizer and wastewater. Often the nitrate is in the form of ammonia or protein first, which through contact with oxygen and certain bacteria, converts to the oxidized form known as nitrate. Sources of nitrate from wastewater include urea, ammonia cleaners, food solids, and bacterial cells. It may also result from the breakdown of organic matter buried in the soil. TOXICITY: Nitrate is generally not toxic to adults or children over the age of two or three years but is associated with a potentially fatal infant disease called methemoglobinemia. In the digestive system of young children, nitrate converts to nitrite, which can pass through the intestinal wall into the blood stream. There it combines with the hemoglobin and interferes with the ability of the blood to carry oxygen. For this reason, methemoglobinemia is referred to as "blue baby" disease. The EPA limits the concentration of nitrate in public drinking water supplies to 10 mg/L. The standard has been lowered from a previous level of 45 mg/L set by the US Public Health Service and the World Health Organization. TREATMENT: due to its solubility in water and negative ionic charge, filtration and other common home water treatment systems such as softening, or iron filtration does not readily remove nitrate. The best method for limiting nitrate in well water is source control. This can include avoiding overdosing of fertilizer near the well and maintaining good separation distances between septic tank leach fields and the well. A special anion exchange filter that contains a media with a strong affinity for negatively charged ions in water, or by a reverse osmosis treatment system or distillation can remove nitrate. TESTING: Nitrate analysis is usually done by one of the several "wet chemical" methods using a spectrophotometer to read the final color endpoint. Specific ion electrodes also can be used to detect the activity of nitrate in water. This laboratory uses several different wet chemical methods approved under the public water supply laboratory certification program. They also have test kits available, which the laboratory uses to perform an inexpensive "screening test", and with which the homeowner can monitor the change in nitrate levels from their well. They recommend comparing the test kit results against a certified analysis from the lab occasionally to verify the accuracy of the kit. We recommend using a specially prepared bottle that has been rinsed in hydrochloric acid for collecting samples. $ Maii�ng Address P ��OK Box 196650 *Anchorage, Alaska 99519 6650 * www muni org � h vG) o Cl) = Q 3 x on O Y > ^ r, C L C \ ® LL• W Cn ��' v x w wto -� L C'� ( a,cOf 0 AW ru 'Y v c c If OSS �. J ( @oYo0 (1 a Y L(1 v c Y v Z s t{ L f0 N C N Y o (�� :> ® '� -'- : TY -7 -.-'.-TT --__ :�liI -•' , f`�\1 z Q _z ._c •� .•- U - -1 a Y v o c � Q N --o O J { ~ to > �. L Q O O� (ll E O a �^ \ L w Q ate-+ y. Q ♦'J O O O O Q — N to 0 z C ° O V Y >- y a 1, 00 , . /\ v vi O w H O x c x \ o c V 1 _ l� ^ '3 O (nX— 0 yo 0 0- v a - N O_ 0 0v c 0 _ N w> o < E /8� vL Q _ y x� o C p4_ O O,y Vml r -+f V a O a \ S: Oc ' f v -0 z a u p z m uj f O \k 0 O j♦ ,r t!j Q v O �/ C '� N O C \`\ hob [O� +\k 11.0 o LLo • a \ S2 Q v Q cz N = V) l n a a) 3 O CV --' ' V z,r;b CD- �h• ��' m to E > - _0 C)a� N c v t N p 2 O Gi o C) v (�'