Loading...
HomeMy WebLinkAboutPROSPECT HEIGHTS #1 BLK 5 LT 1 L4 'L�1�i I I IF I I Municipality of Anchorages L Community Development Department JUN ell) 0 2018 Page 1 of 3 On -Site Water & Wastewater Program 4700 Elmore St. • P.O. Box 196650 Anchorage, AK 99519-6650 • http://www.muni.org/onsite • (907)343-7904 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP181070 PID Number: 015-091-33-000 ❑ New ■ Upgrade Name: EARLENE YAKLEY ABSORPTION FIELD ❑ Deep Trench ❑ Shallow Trench ❑ Bedound Address: 9890 SLALOM DRIVE *ANCHORAGE, AK 99516 ElOther f! Phone: No, of Bedrooms: Soil Rating: Total Depth from origins ode: (907) 346-1509 3 GPD/Sq. FL Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade: h beneath pipe: F Ft. KGravel Subdivision: Block: Lot: Fill added above original grade: Gth: PROSPECT HEIGHTS #1 5 1 j l \�(\� FL Gravel width: v Ft Ft Owns Ip: anger section: Beds Number of lines: Distance between lines: Ft. SEPARATIONDISTANCES Totalabsorp' area: Number of trenches: Dist. between trenches: To Septic Absorption Lift Holding Public/Private From Tank Field Station Tank Sewer Lines So. Ft Ft. Well 100'+ EXISTING - 25'+ TANK 0 Septic ❑ S.T.E.P. ❑Holding ❑Other Manufacturer: Capacity: Surface Water 100'+ - GREER 1000 Gal. Material: Number of compartments: Lot Line 51+ - N/A HDPE 2 LIFT STATION Foundation 101+ Curtain Drain NONE KNOWN Manufacturer: Ca y: Gal. "Pump on" level at: "Pump of 'level at: High water alarm at: Remarks: PER CONTRACTOR, OLD STEEL SEPTIC TANK (INSTALLED 1976) WAS FILLED WITH CONCRETE IN PLACE (SEE ATTACHED PHOTOS). TOP OF TANK INSPECTED BY MOA ONSITE EMPLOYEE TIM ECKLUND ON 5/9/2018. Pump Make & Model Electrical Inspections performed by: ON 4/25/2018 JOHN'S EXCAVATING INSTALLED A NEW CLEANOUT AND MONITORING TUBE ON BOTH THE EAST & WEST ENDS OF THE EXISTING PIPE MATERIAL EXISTING/ House to tank D3034 Tank to D3034 drainfield TRENCH SEE ATTACHED 40 -SCALE Installer EXISTING/ JOHN'S EXCAVATING Drainfield D3034 CO/MT D3034 Inspector GEG, Ltd. BENCH MARK (Assumed elevation) 100.00 Ft. Inspection Location and Description: Dates: 1st 5/9/2018 2nd 3rd 4th TOP OF BACK GARAGE SLAB ENGINEER'S SEAL Community Development Department Approval oo�o o Conditional approval: Date: os��oo ....:.....0 ,J fr G ess, o CE 795 mQ p� Approved- I Vl'i�.0Date: 2 1/18 re... 4�Qaprofessio0°oo / LICENSE #AECC884 Inspection Report_1-1-12.doc ARCEL r PERMIT OSP181070 RECORD DRAWING P015 -0D -33-0: 015-091-33-000 / A T B C DBL1 34.6 8.8 26.8 DBL2 35.4 9.7 26.3 ST1 39.9 14.2 26.9 ST2 44.5 18.9 28.4 STMT 42.2 17.0 25.3 DBL3 46.2 20.5 30.1 DBL4 46.7 20.9 31.1 C01 49.0 24.9 42.6 MT1 50.0 25.7 43.0 CO2 88.7 1 69.0 88.3 MT2 88.3 1 68.7 88.2 (_SEPTIC AREt / PROSPECT HEIGHTS / #1; BLOCK 5, LOT 2A A, \ \ I / 7�- \ Comer / \ 2p JOHN'S EXCAVATING INSTALLED o / NEW CLEANOUT AND MONITORING ^/ TUBE ON BOTH THE EAST AND WEST ENDS OF THE EXISTING TRENCH. / STMT /\ \ / NEW 1000 GALLON\ \ DB 1 &DBL2 / HDPE SEPTIC TANK / DBL3 & DBL4 / \ \ EXISTING TRENCH MT1 5c��1 B GARAGE BARN` \ CO MT2 STABLE .\v , ` \% I GO d i \O �`� mP 06 EXISTING 3 \ BEDROOM d F �„` HOUSE � �`� OLD SEPTIC TANK FILLED WITH CONCRETE IN PLACE d d 4 DRIVEWAY d� SCALE: /� 1"=40' / O .**\n\wC%v%44 01 4p �.. 0 GARNESS ENGINEERING GROUP,• 4 0�'• Ltd:.....:.........................ir .::....10 -----_ CIVIL & ENVIRONMENTAL ENGINEERS -_-e / 0 3701 E. TUDOR ROAD, SUITE 101 • ANCHORAGE. AK 99507 • PHONE (907)337-6179 • FAX (907) 3363246' WEBSITE: wvni.gamessengineenngxom , ;, ...... 0 PREPARED FOR: PHONE NUMBER: PAGE NUMBER: EARLENE YAKELY 346-1509 2 OF 3 rey A7953 ss ��C) ':�I CEJ -7953 Q �m LEGAL DESCRIPTION: DRAWN BY: •� ♦�, cO i 4 ZD �0 • • ::� PROSPECT HEIGHTS #1; BLOCK 5, LOT 1 L.K.B. 'p �•'•••... , + • TYPE OF WORK: DATE: LICENS E/*Ill `S";�� • ,._ RECORD DRAWING 6/20/2018 #AECC8aa LIM r7PE7OS P 181070 RECORD DRAWING PARCEL ID NUMBER: 015-091-33-000 TOP OF TANK INSPECTED BY MOA ONSITE EMPLOYEE TIM ECKLUND ON 5/9/2018 ON 4/25/2018 JOHN'S EXCAVATING INSTALLED A NEW CLEANOUT AND MONITORING TUBE ON BOTH THE EAST AND WEST ENDS OF THE EXISTING (1976) TRENCH. 2" INSULATION (PER CONTRACTOR) FINAL GRADE = 98.18 - 98.35 STI ST2 TOP OF TANK @ INLET = 94.4 TOP OF TANK @ OUTLET = 94.45 INVERT OF BUNG @ INLET = 93.42 NEW 1000 GALLON INVERT OF BUNG @ OUTLET = 93.35 H.D.P.E. SEPTIC TANK - -- GARNESS ENGINEERING GROUP, Ltd ' 1 . ...:....J.4 ..... __---------_-- CIVIL & ENVIRONMENTAL ENGINEERS---- = �i . . 0 Ww 3701 E. TUDOR ROAD, SUITE 101 -ANCHORAGE, AK99507-PHONE (907)337 -6179 -FAX (907)336-3246'EBSITE:games gineering.co ... .ee.eee. ..eeee.e e10 PREPARED FOR: PHONE NUMBER: PAGE NUMBER: Aw EARLENE YAKLEY 346-1509 3 OF 3 ���';. J rC3ness •'_AV LEGAL DESCRIPTION: rj DRAWN BY: 0�♦�•./j••••l��. PROSPECT HEIGHTS #1; BLOCK, LOT. 1 L.K.B.°F�•p•...•„•,/. PSV♦♦ TYPE OF WORK: DATE: LICENSE °°�,;;;`S` M® �♦ HDPE TANK PROFILE 6/14/2018 #AECC894 MUNICIPALITY OF ANCHORAGE "en, On-Site Water&Wastewater Program - PO Box 196650 4700 Elmore Road • _ Anchorage,Alaska 99519-6650 Phone:(907)343-7904 Fax:(907)343-7997 http://www.muni.org/onsite l)ch91nt 9hCH OP PGE On-Site Wastewater Disposal System Permit Permit Number: OSP181070 Effective Date: 5/2/2018 Work Type: SepticTank Upgrade Expiration Date: 5/2/2019 Tax Code Number: 01509133000 Site Legal Address: PROSPECT HEIGHTS #1 BLK 5 LT 1 G:2441 Site Mailing Address: 9890 SLALOM DR, Anchorage Owner: YAKLEY EARLENE J Lot Size in Sq Ft: 93654 Design Engineer: GARNESS ENGINEERING GROUP LTD Total Bedrooms: 3 This permit is for the construction of: ❑ Disposal Field IJ Septic Tank 0 Holding Tank 0 Privy 0 Private Well 0 Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72)and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Received By: -, �� ' Date: 5-4Z"/ g Issued By: e,0,()4 (JJIZ -6' Date: S///g MUNICIPALITY OF ANCHORAGE Community Development Department I- Phone: 907-343-7904 Development Services — Fax: 907- 343-7997 On-Site Water & Wastewater Program Mayor Dan Sullivan On-Site Sewer/Well Permit Application For A Single Family Dwelling Parcel I.D. 015-091-33-000 Property owner(s) Earlene Yakely Day phone 346-1509 Mailing address 9890 Slalom Drive*Anchorage.AK 99516 Site address 9890 Slalom Drive*Anchorage,AK 99516 \ Legal description (Sub'd, Block & Lot ) Prospect Heights: Block 5, Lot 1 Legal description (Township. Section & Range) Lot Size Sq.Ft. Number of Bedrooms 3 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DEWELLING: (®all that apply) Initial ❑ Single Family (SF) Absorption Field ❑ (w/wo ADU) Septic Tank ® Upgrade Duplex (D) I I Renewal ❑ Holding Tank ❑ Multiple Dwellings n Privy ❑ (SF and/or D) Private Well I I Water Storage n THIS APPLICATION INCLUDES A VARIANCE/WAIVER REQUEST FOR: N/A Distance: - I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal codes. GARNESS ENGINEERING GROUP, Ltd. (Signature of property owner or authorized agent) Permit/Rush Fees: c?/`J Waiver Fees: Date of Payment: 5194/e) Date of Payment: Receipt Number: Ulaga/ Receipt Number: Permit No. (SP`/2tOO Waiver No. (Rev.01/11) t _ uanics GARNESS ENGINEERING GROUP Ltd Advanced Treatment 5 Cof t ENGINEERING SALES CONSULTING Dealer April 30th, 2018 Municipality of Anchorage Development Service Department On-Site Water & Wastewater Program 4700 Elmore Road Anchorage, AK 99507 Ref: Proposed Septic Tank Upgrade for Prospect Heights; Block 5, Lot 1 To whom it may concern: The existing 3-bedroom house is served by a private well and private septic system. The existing steel septic tank (installed 1976) is in a state of failure and needs to be upgraded. We are proposing to decommission the existing tank by filling it with concrete and replace it with a new 1,000-gallon H.D.P.E. septic tank. The contractor is to have all pertinent well radii and easements flagged prior to construction and is to maintain a 10'+ separation to all building foundations. In addition, the contractor is to adjust grade over the sewer line to ensure adequate soil cover throughout. We are unaware of any adverse impacts this installation would have on adjacent wells or septic systems. If you have any questions, please contact us at 337-6179. Thank you for your assistance. ( e;eYy Jeffrey . earn-ss, P E., M.S. Presi4 '� 3701 East Tudor Road, Suite 101 *Anchorage,Alaska 99507-1259 Phone: (907)337-6179*Fax: (907)338-3246*Website: www.garnessengineering.com ztt RAbius / too' \ � I // ; — // \ / / \ PROSPECT HEIGHTS#1; / / \ / \ BLOCK 5.LOT 14A / / / ^ f‘',i / V � / / o ,LS / PROSPECT HEIGHTS Si; / \\ \ / BLOCK 5.LOT 2A / // OBJ.,\ \ \\ / -SEPTIC AREA / ��IR \ / 7j ..... _/// \\ / ,opt \i AREA PROSPECT HEIGHTS#1: \ \\ / —sBLOCK 5.LOT 148 \\\ \ /�—;,-4.."1 ��/ \ \ / / \ \ / / / N \ / ••••, // \\\T/ \ 'Ay \ / / /0 \ / \ \ N \ / \ // / \\ \ / I \- \\\\ \ 1 / I /' / \\ ( / HEITS PROSPECT / / ',NV\ :.' k40USA / BLOCK 2.LOT 28 \ •• / \ / pT1C AREA \ P / / \ // \ y VC PROSPECT HEIGHTS#1: \ BLOCK 2.LOT 27 / PROSPECT HEIGHTS R1; \ BLOCK 5,LOT 15 \ � WELL LOCATION PER MIKE ANDERSON. P.E.2015 DESIGN DRAWING/SITE PLAN, �� APPROXIMATE SEPTIC LOCATION PER 100'WELL RADIUS I Q� HOMEOWNER ON 3/2212018 /——— .I O`S / / 3v , / / / / ,00,„,„„i (APPROXIOf S \ / \�_ / / pTIC AREA I ) 5C,JSS' ` \\ � .v \ / 1pTIC AREA /' PROSPECT HEIGHTS 81;TRACT Al —— ——— PROSPECT HEIGHTS Si; i / / / BLOCK 2.LOT 28 S ALE: / \// 1"=100' / 7 \ pTIC AREAA /i/ / \. \ .��vi\\ 111 **'S 4 ,�V .CO . •S/ Vii • GARNESS ENGINEERING GROUP, Ltd -' 4 -' •�* ENGINEERING a SALES J CONSULTING 3701 E.TUDOR ROAD,SUITE 101'ANCHORAGE,AK 99507'PHONE(907)3376179'FAX(907)3383246'WEBSITE:www.gamessengineering.com 0 ; PREPARED FOR: PHONE NUMBER: PAGE NUMBER: ,0.�'�• rky A. •. :SS�.'� EARLENE YAKELY 346-1509 1 OF 1 ��/J, : C 79 '�� PROJECT/LEGAL DESCRIPTION: DRAWN BY: v.�(��••• u�30 �•'�' PROSPECT HEIGHTS#1; BLOCK 5, LOT 1 L.K.B. 1,c�Q•••••• ....... ••'•\P\, ,4p-- . TYPE OF WORK: DATE: LICENSE ,1.MOFESS 1 �•• SITE PLAN 4/9/2018 #AECC884 ����1� J / / GEG,Ltd.HAS A 8 PAGE SPECIFICATION LETTER THAT PERTAINS TO THIS DESIGN.TO CONTRACTOR IS TO HAVE ALL PERTINENT OBTAIN A COPY OF THE LETTER CONTACT EASEMENTS AND WELL RADII PROFESSIONALLY GEG.BY PROCEEDING FORWARD WITH THIS / LOCATED&FLAGGED PRIOR TO CONSTRUCTION INSTALLATION,THE ENGINEER,WELL DRILLER, AND MAINTAIN A 5'+SEPARATION TO THE EXISTING CONTRACTOR AND PROPERTY OWNER AGREE / TRENCH AND 10'+TO ALL FOUNDATION WALLS. THAT THEY HAVE READ THESE (SEPTIC PR�� SPECIFICATIONS AND AGREE TO ACCEPT THE / ''' TERMS TERMS AND CONDITIONS OUTLINED. / \ PROSPECT HEIGHTS / \ \ #1;BLOCK 5,LOT 2A \ \ \ i \ \ I / / �4' / \ ASF41 \ \ / I ., / \ \ �� PROSPOSED 1000 GALLON \ \ ^ / J/ GREER H.D.P.E.SEPTIC TANK •••.., \/\ / / \ / \ \ / INSTALL PRE-TANK AND \ \ / POST-TANK DOUBLE CLEANOUTS • \ / \/ \ APPROXIMATE LOCATION OF EXISTING SEPTIC / • \ I \ \ / TANK PER CLEANOUT LOCATIONS \ \ (EXISTING BARN IS TO BE DEMOLISHED OR TANK \ \ / IS TO BE FILLED WITH CONCRETE) \ / / 700,_ \ \ \ APPROXIMATE LOCATION OF EXISTING DRAINFIELD GARAGE -`•.4 R"O/(is I \ \ \ \ \ 5- A8- -1,' ....,ss. _e. ./;;;...-- ...... STABLE I INSTALL \ _1CLEANOUT . • 41,0 0 f /AP' / \po ff \ ////�EXISTING y WBEDROOM \0„ 1 j \ HOUSE 4 • \ el \ . -4 (DRIVEWAY )k . . \ \ • • ' • A \ \ N L _ >_ — � / • • S ALE: �iL�� • to$C)"_II 9{ 1'•=40' • • v 1 . / C° / .41_ OF ,,1 4IP4P•S\>' .'''''''''''i...'.. ic7A ..der ti mil All&sraii. A.I GARNESS ENGINEERING GROUP, Ltd 4' ''• . '=* �'; ENGINFFRING a SALES.CONSULTING �: 0 3701 E.TUDOR ROAD.SUITE 101•ANCHORAGE.AK 99507'PHONE(907)337-6179'FAX(907)338-3246'WEBSITE.www.gamessengineering.com / •%• •• PREPARED FOR: PHONE NUMBER: PAGE NUMBER: 0 "y A• s = EARLENE YAKELY 346-1509 2 OF 2 •��/ CEj-795 /p '_� PROJECT/LEGAL DESCRIPTION: DRAWN BY: ��' •,••• 1 3 v .�•y-'� � PROSPECT HEIGHTS#1; BLOCK 5, LOT 1 L.K.B. • • PROFESS �P�,��• TYPE OF WORK: DATE: LICENSE44 �'♦��• SEPTIC TANK UPGRADE 4/30/2018 / / / \ o / \ / \ u, // \ / \ / o \ \ 00 SB;�,90 N \ \ S ��ti o \ "% F1 i. '� 3 G�W r J N Z !�s \ N rn \ o N \_ o o Is_31— 0 5 %%4') �- /" �/ D N / / \\\\ N .61 N l m e r \ z n F13 p / N ‘1,1 ... \ P 'O g-r• / N \ .,....,4 i -• N N= N. + f t0 gat • •. C z g oe ? • • s \ .0 w / i �A o,� 1 / / ��� / P/ / ./ / m z \ N\ \\/ z7 2 F ---- •\</t5'"----\ \ \ 40 / PLOT PLAN _ AS BUILT _i. SCALE 1" -X GRID SW 244) Project No. 18-088/Al Associates, 11500 Daryl Avenue, Anchorage, Alaska 99515-3049 Lang & inc. (907) 522-6476 Phone \ (907) 522-4625 Fax `\ Professional Land Surveyors k.nlangsurvycom -,--e_ 0 F A t '\, jonathanOlangsurvey.com -'S`•'*•••.•. 1s 1 I hereby certify that I have surveyed the following described property: :4'..'.. ;\ '.1.- 1/ LOT 1, BLOCK 5, PROSPECT HEIGHTS SUBDIVISION - ADDITION No. 1 (PLAT No. 67-23) * 49� . * Anchorage Recording District, Alaska, and that the improvements situated thereon are , / within the property lines and do not encroach onto the property adjacent thereto, that 5 _ / 4 i no Improvements on the property lying adjacent thereto encroach on the surveyed KEN LAN;ii i premises and that there are no roadways, transmission lines or other visible • easements on said properly except as Indicated hereon. 1, • /1:1 MS Dated this the Day of PP Mrd of Anchorage, Alaska ‘ V\It Is the responsibility of the owner to determine the existence of any easements, ` covenants, or restrictions which do not appear on the recorded subdivision plot. AECC963 GREL.', R ANCHORAGE AREA BOR,, Department of Environmental Quality 3330 C Street Anchorage, Alaska 99503 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM NAME. ~/~-..-) i~x.. '~'~ .~--~-~-L0.~,v-....._,. MAILING ADDRESS ~('~i"~ -:.~%~c} i.~ PHONE:{<//F-/ SEPTIC TANK: DISTANCE (. FROM WELL ) INSIDE LENGTH INSIDE WIDTH LIQUID DEPTH NUMBER OF COMPARTMENTS LIQUID CAPACITYz/~'~ GALLONS. TILE DRAIN FIELD: DISTANCE FROM WELL .-~ldo FOUNDATION NUMBER OF LINES I DISTANCE BETWEEN LINES ABSORPTION AREA DEPTH: TOP OF TILE TO FINISH GRADE NEAREST LOT LINE TOTAL LENGTH OF LINES ~-~ TRENCH WIDTH IN. TOTAL EFFECTIVE SQ. FT. LENGTH OF EACH LINE DEPTH OF FILTER MATERIAL BENEATH TILE ABOVE TILE V IN, WELL: BUILDING NEAREST NEAREST FOUNDATION LOT LINE SEWER LINE DEPTH SEPTIC SEEPAGE , TANK , SYSTEM CESSPOOL , OTHER SOURCES APPROVED_ DISAPPROVED REMARKS DISTANCE FROM: DISTANCES: INSTALLED BY: ~¥'t-'t'~.~,~.-L,- SEWER LINE DEPTH: PIPE MATERIAL: ~.~g LOT SLOPE: REMARKS: DIAGRAM OF SYSTEM G.A.A,B. , ~ GRE~. ~R ANCHORAGE: ARE:A BO! 'UGH DEPARTMENT OF ENVIRONMENTAL QUALITY t~ / / PE ' , 3~30 "C"STREET ANCHORAGE, ALASKA 99S03 TELEPHONE 274-456, ~ SEWAGE DISPOSAL SYSTEM -- APPLICATION AND PE~I~e INSTALLATION OF: SEPTIC TANK SEEPAGE PIT DRAIN FIELD ~ OTHER FINANCED THROUGH TO BE INSTALLED DY ~/~' (~~ /~:~O~ song T~ST ~SULTS ~.~ ~ ~Z~:~ NOTE~ THIS PER~IT IS NOT VALID WITHOUT 5OIL FINAL INSPECTION: 24 HOUR NOTICE REQUIRED. BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION BY THE DEPARTMENT OF ENVIRONMENTAL QUALITY AUTHORITY WILL BE SUBJECT TO PROSECUTION. MINIMUM DISTANCES, REQUIREMENTS FOUNDATION TO SEPTIC TANK ~ / . DRAIN FIELD SEPTIC TANK TO SEEPAGE PIT WALL f / ~ SEPTIC TANK , DRAIN FIELD TO NEAREST LOT LINE. WELL TO SEPTIC TANK / ~) DRAIN FIELD WATER MAIN TO SEPTIC TANK DRAIN FIELD SEPTIC TANK, . /~--~ , SEEPAGE PIT TO RIVER, LAKE, STREAM. · SEEPAGE PIT /~ / ALSO CONSIDER AREA WELLS. , SEEPAGE PIT J~ / DRAIN FIELD CAST IRON INTO AND OUT OF SEPTIC TANK AND INTO CRib CROSSING GAP OF EXCAVATION 5 FEET INTO UNDISTURBED SOIL. 4 INCH DIAMETER CAST IRON SIPHON PIPES ON SEPTIC TANK AND SEEPAGE PIT FITTED WITH AIRTIGHT REMOVABLE CAPS. GRAVEL SACKFILL CONFORM TO BOROUGH REGULATIONS REGARDING INSTALLATION. OR LICENSED DESIGNER DIAGRAM OF SYSTEM CERTIFY THAT I AM FAMILIAR WITH THE REQUIREMENTS OF GREATER ANCHORAGE AREA BOROUGH ORDINANCE NO. 28.68 AND THAT THE ABOVE DESCRIBED SYSTEM IS IN ACCORDANCE WITH SAID CODE. ~'-~,2~ ,~.~...~/~7_,,~ ~'/~;,/ --- ~"~//~2./~-d~'" ~/~. DATE APPLICANTS SIGNATURE ~/~/~ ~ ~ ~ ''~ R T.H. 1 4-22-75 Silt w/some Gravel 0.0~ --0.5' Sandy.Silty Gravel (GM) / --. 4.0? Gravelly Sand w/ Some Silt & Cobbles (SM) _ -~12o5' Silty Sand w/ Some Gravel (SM) No Water Table .20.0' T.D. Note:- Log Represents Lot 1 Block 5 Prospect Height Subdivision Engineering & Geological Consulfants Inc. ANCHrjRAG~ FAIRgA)IX$ ALASKA JuNEau Lee Struer Log of Test Hole Anchorage, Alaska ANCHORAGE FAIRBANKS CONSULTANTS, INC. JUNEAU April 22~ 1975 R & M Noo 562017 Mr. Lee Strue~ P. O.-Box 4-2364 Anchorage, Alaska RE: Test Hole and Soil Log Report for Sanitary System Lot 1 Block 5 Prospect Heights Subdivision Dear Mr. Struer: We are s,~hmitting herewith the test boring results and our comments regarding soil conditions encountered at the subject site. This investigation was performed in accordance with your request of April 22, 1975, and those procedures outlined in a letter dated December 19, 1974, by Mr. Roll Strickland of the Greater Anchorage Area Borough Department of Environmental Quality. A single test hole was put down within the Lot 1 area for the purpose of defining general subsurface soil conditions for the proposed sanitary system. Excavation was accomplished with an auger type drilling rig and the test hole was extended to a total depth of 20.0 feet below ground surface. One sample was recovered from the test hole and retained for grain size analysis. The results of this sample are enclosed. The final log prepared for the test hole has been included in Drawing A-01. Ground water was not encountered in the .test hole. We appreciate being given this opportunity to be of service to you. Should you have any questions with regard to the above, please do not hesitate to contact us. Very truly yours, R & M CONSULTANTS, INC. James W. Rooney ~qR:sc /xc: GAAB MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION DIVISION OF ENVIRONMENTAL HEALTH CERTIFICATE OF INSPECTION FOR HEALTH AUTHORITY APPROVAL OF ON-SITE SEWER AND WATER FACILITY 264-4720 Application Date 1. GENERAL INFORMATION (a) Legal Description (include lot, block, subdivision, section, township, range) Location (ad,ess or directions) (b) Applicant Name ~/~g- Applicant Address (c) Applicant is (check one): Lending Institution ~; Owner/builder ~; Buyer D; Other ~ (explain); Telephone: Home ~.~'~, "--?'.~.~ Business (d) Lending Institution Address '/~-&¢~ (e) Real Estate Company and Agent Address Telephone Telephone (f) Mail the HAA to the following address: TYPE OF RESIDENCE Single-Family I~ Multi-Fa~]~ther Number of Bedrooms WATER SUPPLY Individual Well¢ Community [] Public [] Note: If community well system, must have written confirmation from the State Department of Environmental Conservation attesting to the legality and status. SEWAGE DISPOSAL Onsite ~ Public [] Community [] Page I of 2 Holding Tank [] Note: If community well system, must have written confirmation from the State Department of Environmental Conservation attesting to the legality and status. 5~ ENGINEERING FIRM PROVIDIN~ INSPECTIONS, TESTS, FILE SEARCH, DA'I'A AND INFORMATION As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of thi~ Health Authority Approval shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate. for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on the date of this inspection. NameofFirm 0-O,~"Jr', ~'V~i~5 ,~Z~vi¢,,~ Telephone 3~ ~--~ Date mc~ ~ i ~ -- - ' ' DHEP APPROVAL Approved for "~ Approv, ed )'~, Disapproved Terms of Con~itJ6nal Approval bedroomsby ~~1' ~~ Date // - 7--(5~ Gonditional CAUTION The Muncipality of Anchorage Department of Health and Environmental Protection (DHEP) issues Health Authority Approval certificates based solely upon the representations given in paragraph 5 above by an independent professional engineer registered in the State of Alaska. The DHEP does this as a courtesy to purchasers of homes and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHEP do not conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or Omissions in the professional engineer's work. Page 2 of 2 72-025 (11/84} MUNICIPALITY OF ANCHORAGE (MOA) HEALTH AUTHORITY APPROVAL (HAA) CHECKLIST - FEBRUARY 1984 264-4720 Legal Description: /'3 WELL DATA Well Classification "~t ~.-',~.- ~ If A, B, C, D.E.C. Approved (Y/N) Well Log Present (Y/N) ~ Date Completed ! ¢J ''~ ~ Yield Total Depth 3,~'~; Cased to + ~0 t~ Static Water Level Casing Height Above Ground Electrical Wiring in Conduit (Y/N) Separation Distances from Well: To Septic/Holding Tank on Lot 5'~¢ ~,,~-~, On Adjoining Lots Depth of Grouting Pump Set At Sanitary Seal on Casing (Y/N) Depression Around Wellhead (Y/N) To Nearest Edge of Absorption Field on Lot To Nearest Public Sewer Line Cleanout/Manhole /t~ Water Sample Collected by Water Sample Test Results Comments ; On Adjoining Lots To Nearest Public Sewer To Nearest Sewer Service Line on Lot ~.~ r~ ; Date O~ / B. SEPTIC/~I~II~I~.O'TANK DATA Date Installed I ~ 7&, Size / OOO~ No. of Compartments Standpipes (Y/N) )'/ Air-tight Caps (Y/N) /V' Foundation Cleanout (Y/N) Depression over Tank (Y/N) ~ Date Last Pumped Pumping/Maintenance Contract on File (Y/N) ~ ; for Holding Tank High-Water Alarm (Y/N) ~ ~ Separation Distances from Septic/Holding Tank: TO Water-Supply Well /~ ~ '/(¢'¢'~*1¢//~/,~¢.;/) To Property Line '70 · To Water Main/Service Line "/- / dO f Course '¢' /' 0 0 ~ Temporary Holding Tank Permit (Y/N) To Building Foundation ¢ 0" To Disposal Field '¢'-,5~ ¢ To Stream, Pond, Lake, or Major Drainage Comments Page 1 of 2 ABSORPTION FIELD DATA ': '..~. Soils Rating in Absorption Strata Date Installed _ ( ~'7 ~ Width of Field Square Feet of Absorption Area Depression over Field (Y/N) Results of Last Adequacy Test Separation Distance from Absorption Field: To Water-Supply Well To Building Foundation To Water Main/Service Line To Stream/Pond/Lake/or Major Drainage Course To Driveway, Parking Area, or Vehicle Storage Area Comments .~-- ~ .~'/~ ¢-'~/o Type of System Design Length of Field Depth of Field Gravel Bed Thickness Standpipes Present (Y/N) Date of Last Adequacy Test To Property Line ~ ..¢" / To Existing or Abandoned System on ; On Adjoining Lots ~¢-¢~ o f To Cutbank (if present) /tJ k~ D. LIFT STATION Date Installed Size in Gallons "Pump On" Level at High Water Alarm Level at Tested for Electrical Codes (Y/N) Dimensions Manhole/Access (Y/N) "Pump Off" Level at Vent (Y/N) Pumping Cycles during Adequacy Test. Meets MOA Comments ** Check Permitted Bedroom Rating Against HAA Request ** I certify t,~,/I,~y~V~ ?~c~ked, verified, or conformed to all MOA and HAA guidelines in effect on the date of this inspection. Signed ~¢/N'~'~-'°'''''''"'~ Date 0~+ ~_~-Z~ { ~ ~ Company G H, e-,ry. No. Receipt No. b o Date of Payment Amount: $ Page 2 of 2 72-026 (11/84) un cipaiitYo{ Anchorage P.O. buX 196650 ANCHORAGE, ALASKA 99519-6650 (907) 264-4111 TONY KNOWLES, MA YOR DEPARTMENT OF HEALTH & HUMAN SERVICES November 10, 1986 Henry Wilson P.E.' 9601 Buddy Werner Dr. Anchorage, Alaska 99516 Re: Lot 1 Block 5 Prospect Heights waiver approVal Dear Mr. Wilson: The waiver has been approved for the above mentioned parcel. is completed and available for pick-up at D.H.H.S. Thank you for your cooperation. Sincerely, Daniel J. Roth Civil Engineer On-Site Services It HENRY WILSON 9601 BUDDY WERNER DR.: ANCHORAGE, AK g9515 (gO7) 346-2000 CHARLES A. LANDERS SR BOX 192-A, MYRTLE DR. EAGLE RIVER, AK 99577 (907) 694,9098 November 5, 1986 Daniel J. Roth Civil Engineer, On-Site Services Dept. of Health &ttuman Services P. O. Box 6650 Anchorage, AK 99502-0650 Re: Lot 1, Block 5 Prospect Heights Waiver of Separation Distance between well on subject lot and leach field of Lot 2A, Block 5 (96' to standpipe) Dear Hr. Rotn. Those items mentioned in your letter of October 28, 1986 have been corrected. Very truly yours, CONSTRUCTING ENGINEERS, INC. t~enry ti. Wilson P.O. BOX 6650 ANCHORAGE, ALASKA 99502-0650 (907) 264-4111 TONY KNOWLES, MA YOR DEPARTMENT OF HEALTH & HUMAN SERVICES October 28, 1986 Henry Wilson, PoE. 9601 Buddy Werner Dr. Anchorage, Alaska 99516 Subject: Lot 1 Block 5 Prospect Heights Subdivision Waiver Request, WR86-150 Dear Mr. Wilson: Your request for a waiver of the 100 foot separation distance required between the on-site septic system of lot 2A Block 5 Prospect Heights Subdivision and the well on lot 1 has been granted. This separation requirement will be waived to 90 feet subject to the following conditions: Upon personal inspection the well casing was found not to be the required 1 foot above ground surface. This requirement must be met. The ground around the well casing must be graded to slope away from the well thus surface contamination will not flow towards the well. 3. The electrical box connecting the conduit to the sanitary seal must be threaded properly into the sanitary seal to prevent surface contamination from entering into the well. Documentation that the conditions of this waiver have been met must be provided and certified by a Professional Engineer in order for this waiver to be considered valid. Sincerely, Daniel J. Roth Civil Engineer On-site Services HENRY WILSON g601 BUDDY WERNER DR.: ANCHORAGE, AK ggSI6 (907) 346.2OO0 Con~ En lineers, Inc. CHARLES A. LANDERS SR BOX 192.A, MYRTLE DR. EAGLE RIVER, AK 99577 (go7) 694-g098 October 22, 1986 Stephen S. Morris Civil Engineer, On-Site Services Dept. of }~ealth & Human Services P. O. Box 6650 Anchorage, AK 99502-0650 HEALTH & OCT 2 1986 RECEIVED Re: Lot 1, Block 5 Prospect Heights Waiver of Separation Distance between well on subject lot and leach field of Lot 2A, Block 5 (96~' to standpipe) Dear Mr. ~orris: Using Mr. Erickson's memo of January 3, 1985 as a guide, and our knowledge of the area for data, we compute: A. Water table depth 100' Depth to bottom system 15' 85' Ce Soil Sorption 50% sand 50% silt Permeability 50% sand 50% silt D. Water Table Gradient % slope 0% E. Horizontal Separation 90' Point value 6.0 Point value 2.5 Point value 1.75 Point value 2.9 Point value 2.6 Total point value = 15.75 Subject property has a three-bedroom home on a 2.15 acre lot which is average for the bulk of this large lot subdivision. (Adjacent lots vary in size from 1 to 3.3. acres) ineers, Inc. Fn HENRY WILSON ,--H CHARLES A. LANDERS 9601 BUDDY WERNER DR.: SR BOX I92-A, MYRTLE DR. ANCHORAGE, AK gg516 ~¥~.~ EAGLE RIVER, AK 99577 (907) 694-gOg$ (9o7) 346-~ .......... ~,,1r. Stephen S. Morris October 22, 1986 Page 2 Another consideration is that the files reveal that both subject well and subject leach field were in place on September 1, 1976 when subject lot was inspected and approved by the G.A.A.B. ,The installations have served some ten years with no ill effects. We request waiver of the estimated 90' separation between subject's well and the adjacent leach field. Very truly yours, CONSTRUCTING ENGINEERS, INC. Henry H. Wilson, P.E. u, Municipality of Anchorage 0 , On-Site'Water and Wastewater Program �, F (907) 343-7904 Certificate of On -Site Systems Approval Parcel I.D.015-091-33 Expiration Date: 6 -3e 20 20 1. GENERAL INFORMATION: Complete legal description Prospect Heights #1: Block 5, Lot 1 Location (site address) 9890 Slalom Drive *Anchorage, AK Current Property owner(s) Day phone Mailing address Real Estate Agent Bob Boldinq Day phone 907-230-0700 2. TYPE OF DWELLING: ® Single Family (w/wo ADU) . ❑ Duplex k ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 3 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well Individual z Individual Water Storage ❑ Holding Tank ❑ Community Class_._.Well ❑ Community } ❑ Public Water System ❑ Public Sewer ❑ Waiver/Variance request for. Distance: Received by: Date:' COSA to be released to the engineer, unless otherwise requested by the engineer: COSA Fee $ 5-5D Date of Payment 3AZ20 Receipt Number a16?5__q � COSA # 03ON6112Z Waiver Fee $ Date of Payment Receipt Number Waiver # 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm: Garness Engineerinq Group, Ltd (GEG) Phone: 907-337-6179 Address: 3701 East Tudor Road, Suite 101- Anchorage, Alaska 99507 Engineer's Printed Name: Jeffrey A. Garness Date: In conducting this evaluation, GEG provided an engineering evaluation of the well and/or septic system in accordance with the guidelines and regulations established by the Municipality of Anchorage and industry practices. The reported results describe the condition of the system/s on the date/s of the evaluation. Separation distances were measured to readily identifiable features. Hidden defects or encroachments may exist that were not identified during the evaluation. The operational life of all wells and septic systems depend upon a variety of variables, including but not limited to, soil conditions, groundwater levels (that may fluctuate during the year), quality of construction (materials and workmanship), and the water usage of the family utilizing the system/s. These conditions can vary, and are outside the control of GEG. Satisfactory test results do not guarantee future performance of the system/s; therefore, GEG makes no warranty (express or implied) regarding the future performance of the well or septic system. GEG makes no representation whether an alternative well or septic system can be installed on the property in the event either of the current systems fail to perform adequately in the future. The content of this report is for the sole benefit of the person/party that retained GEG to perform the evaluation. Reliance upon the information provided in this report by any other person or party (including subsequent property purchasers) is not authorized, nor will it confer any legal right whatsoever. 6. DkC SIGNATURE System #1 Approved for bedrooms System #2 Approved for Disapproved Conditional approval for bedrooms bedrooms, with the fo 0 OF ' ........... ......... 7�. X04.•�/ CET/ 7 4 (I, 3 / Z %4,Z rofessio�°o� #AECC884 OF t �i/i QQ �� CATER At4D z Un§;�p�ATER o1 "O B . �-- �` Original Certificate Date: S-31-2-620 The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist _ Q Nitrate Advisory Septic System Advisory Arsenic Advisory _ Well Flow Advisory_ Other 1 �, Legal Description: PROSPECT HEIGHTS #1; BLOCK 5, LOT 1 If more than 1 septic system on lot: COSA Checklist # of A. WELL DATA ❑ Well log is filed with Onsite (or attached) Date drilled 1976(?) Total depth *205.3+ ft Cased to U N K ft ❑ Sanitary seal is functioning correctly ❑ Wires are properly protected Casing height (above ground) 12+ in. Date of flow test for COSA 3/22/18 Parcel ID: 015-091-33 Structure served by this system Well production at time of test 0.85+ gpm Water storage tank volume N/A gallons Well disinfected for coliform test? ❑ Yes ❑ No ❑ Coliform bacteria is Negative Nitrate 8.49 mg/L ❑ Nitrate less than MRL (ND) Arsenic ug/L ❑ Arsenic less than MRL (ND) Collected by GEG Date of Sample 3/11/20 Static water level at beginning of test 42.7 ft. Comments *PER GEG FIELD DATA. WELL IS 350 FEET DEEP PER 1986 HAA B. TANK DATA Age of tank(s) <2 years Tank type/material HDPE Measured operating fluid level in septic tank NEW ❑ Standpipes/foundation cleanout per record drawing Date of pumping C. LIFT STATION ❑ Required maintenance c Age of lift station Lift station materi9.. D. ABSORPTION FIELD DATA Which system tested (date installed) 9/1"976 Adequacy test date 4/27/18 IN ALL standpipes present per record drawing Results ❑✓ Pass For 3 bedrooms Total measured depth from grade 11.56 ft (max) Fluid depth prior to test 0 in Measured depth to pipe invert from grade 5 ft (min) Water added 500 gal ❑ N/A — pressurized field 0 New depth in ❑ Monitor tubes go to bottom of effective. If not, state 0 depth into effective 6.e6 Elapsed time min P ❑ Code -required soil cover over field Final fluid depth 0 in r_1 System presoaked Absorption rate 450+ gpd (Required if vacant for greater than 30 days prior to Any rejuvenation treatment (past 12 months) NO date of test) Gallons introduced N/A gallons If yes, enter date N/A Comments/Deficiencies: JOHN'S EXCAVATING REPLACED THE EXISTING 6" SUMP WITH ANEW MONITORING TUBE AND CLEANOUT (INSTALLED AT BOTH ENDS) BOTH MT'S WERE DRY DURING GEG SITE VISIT ON 2/27/2020 COSA Checklist yellow sheet E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well) Septic Tank/Lift Station on Lot > 100' ❑✓ Yes if No Community Sewer Manhole/Cleanout > 100' r,7, Yes if No ft M Yes if No ft Neighboring Tank > 100' M✓ Yes if No ft Private Sewer/Septic Line > 25' Q Yes if No ft Absorption Field on Lot > 100' F✓ Yes if No ft Holding Tank > 100' Yes if No ft Neighboring Absorption Fields > 100' ft Community Wells > 200' Yes if No ft Animal Containment > 50' Yes if No ft M✓ Yes if No ft Manure/Animal Excreta Storage > 100' Community Sewer Main > 75' ❑✓ Yes if No ft F/� Yes if No ft From Septic/Holding Tank on Lot to: (Please enter distances if less than required) Building Foundations > 10' 0 Yes if No ft Surface Water > 100' Q Yes if No ft Property Line > 5' ❑✓ Yes if No ft Wells on Adjacent Lots: Absorption Field > 5' M Yes if No ft Private Wells > 100' 0✓ Yes if No ft Water Main > 10' Q Yes if No ft Community Wells > 200' Yes if No ft Water Service Line > 10' F� Yes if No ft If septic tank is under driveway comment below From Absorption Field on Lot to: (Please enter distances if less than required) Building Foundation > 10' Yes if No ,� ft If absorption field is under driveway comment below Property Line > 10' Yes if No ft Wells on Adjacent Lots: Water Main > 10' 0 Yes if No ft Private Wells > 100' Q✓ Yes if No ft Water Service Line > 10' Q Yes if No ft Community Wells > 200' Yes if No ft Surface Water > 100' Yes if No ft F. ENGINEER'S COMMENTS <, ' Iy ;Cam w �-' � CTP D �-�,`�.-� •� -- �:� � mss' ��`��"'J G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. COSA Checklist yellow sheet OF I r* -7 9 k� I J f y Garnes . CE— V-7 s ' • .� •mac G -Z cA� 0,pro fession°moo #AECC884 www.muni.org/onsite Nitrate Advisory Certificate of On -Site Systems Approval # OSC201121 Subdivision: Prospect Heights #1, Block: 5, Lot: 1 A water sample revealed a nitrate concentration of 8.49 milligrams per liter (mg/Q. The Environmental Protection Agency (EPA) has established a maximum contaminant level (MCL) of 10.0 mg/L for public drinking water systems. While private wells are not subject to this regulation, EPA standards are based on existing health information and can therefore be used to gauge the relative quality of water from private wells. Please see the attached "Nitrate Fact Sheet" for important information regarding nitrate. This advisory must be attached to all copies of the subject Certificate of On -Site Systems Approval. 'fitt� �� Madmg Address P, O Box 196650 *Anchorage, Alaska�99519`6650 *www muni org From Northern Testing Laboratories, Inc. Nitrate is a negatively charged compound of nitrogen and oxygen, which is very soluble in water. Nitrate is not readily filtered or otherwise removed in the soil and can pass rapidly into ground water wells. SOURCE: Nitrate is a major component of fertilizer and wastewater. Often the nitrate is in the form of ammonia or protein first, which through contact with oxygen and certain bacteria, converts to the oxidized form known as nitrate. Sources of nitrate from wastewater include urea, ammonia cleaners, food solids, and bacterial cells. It may also result from the breakdown of organic matter buried in the soil. TOXICITY: Nitrate is generally not toxic to adults or children over the age of two or three years, but is associated with a potentially fatal infant disease called methemoglobinemia. In the digestive system of young children, nitrate converts to nitrite, which can pass through the intestinal wall into the blood stream. There it combines with the hemoglobin and interferes with the ability of the blood to carry oxygen. For this reason, methemoglobinemia is referred to as "blue baby" disease. The EPA limits the concentration of nitrate in public drinking water supplies to 10 mg/L. The standard has been lowered from a previous level of 45 mg/L set by the US Public Health Service and the World Health Organization. TREATMENT: due to its solubility in water and negative ionic charge, filtration and other common home water treatment systems such as softening or iron filtration does not readily remove nitrate. The best method for limiting nitrate in well water is source control. This can include avoiding overdosing of fertilizer near the well and maintaining good separation distances between septic tank leach fields and the well. A special anion exchange filter that contains a media with a strong affinity for negatively charged ions in water, or by a reverse osmosis treatment system or distillation can remove nitrate. TESTING: Nitrate analysis is usually done by one of the several "wet chemical" methods using a spectrophotometer to read the final color endpoint. Specific ion electrodes also can be used to detect the activity of nitrate in water. This laboratory uses several different wet chemical methods approved under the public water supply laboratory certification program. They also have test kits available, which the laboratory uses to perform an inexpensive "screening test", and with which the homeowner can monitor the change in nitrate levels from their well. They recommend comparing the test kit results against a certified analysis from the lab occasionally to verify the accuracy of the kit. We recommend using a specially prepared bottle that has been rinsed in hydrochloric acid for collecting samples. MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT to 9 907-343-7904 On -Site Water and Wastewater Section Fax: 343-7997 www.muni.org%onsite Well Water Advisory Certificate of On -Site Systems Approval # OSC201121 Subdivision: Prospect Heights #1 Block: 5, Lot: 1 This well's productivity was determined to be .85 gallons per minute. The minimum well productivity required under (AMC 15.55) for a 3 -bedroom residence is. 31 gallons per minute or 150 gallons per day per bedroom. Although the subject well currently exceeds this minimum requirement, all parties concerned are advised that the production capacity of the well may fluctuate. Restriction of non- critical water uses such as washing cars and watering lawns and gardens may be required. This advisory must be attached to all copies of the subject Certificate of On -Site Systems Approval. -i?,sr..... Mailing Address P �O Box 196650. Anchorage, Alaska 99519 6650 www muni o�rg � 4 � � � �' Jeff Garness From: Sonja Blewett Sent: Wednesday, March 25, 2020 1:04 PM To: Jeff Garness Subject: Regarding 9890 Slalom Hello, The tank was just upgraded 2 years ago and there is only 1 person living in the home. We were hoping to waive the pumping receipt as the tank is new and Earlene who Is elderly is the only one living in the home. Sincerely, Sonja Blewett Corporate Secretary/Treasurer Garness Engineering Group, Ltd, 3701 E. Tudor Road, Suite 101 Anchorage, Alaska 99507 Phone: (907) 337-6179 Fay:: (907) 338-3246 Website: www.garnessengineering.com N Frontier Surveys, LLC Project No: 20-055 Ordered By: Bob Bolding Scale 1" = 60' / LOT 14 ss8• �\ qy \ H Ory / i /p0 V 2 CAR Q SFS\ 'St GARAGE / BARN BARN ^ 6.6 2'v ryp 1 N/ { 235.2 0 Lot 1, Block 5 Prospect Heights #1 N 2.15 Acres +/- T 9890 Slalom Drive a LOT 15 2 Story Wood Frame House c w/Attached 1 Car Garage N `'� Scy�ssoR,vF �.�L1G>♦.— — y Electric Meter/Outside Power IQ, Telephone Pole —x—Overhead Utility Gas Meter ® Deck Fence LT, Tel. Pedestal 11 Septic W; Water Well YJ Mailbox e� Elec. Pedestal Date: 3/2/2020 Plat: 67-23 Grid: N/A LOT2 L�0 _^1FLG�Q ry0• �� ry � �p ryp. qy 'ry �20' UTIL. ESMT. OH Oy \ \ 7 fI General Notes: 0 30 60 120 1. This document is created for the purpose of a single property transaction and is subject to Federal Copyright Laws. 2. Excepting for gross negligence, the liability for this survey shall not exceed the cost of preparing this survey. 3. All measurements/setbacks are to the visuallapparent building footprint. Scale in Feet 4. All dimensions to property lines are plus/minus 0.1 ft. O F t /,� t t t t 11 This survey lies with rtgage is and conditions at he time of hes rvey`Thi odocument oton es not constitute a boundary isndards. The survey represents lsubject • • • 111 survey and to any inaccuracies that a subsequent boundary ..q �,�P •' ' ' • survey may reveal. It is the responsibility of the Owner to determine the existence of any easements, covenants, or restriction which do no appear on the reord Under 47 -' '. '9 /// plat. no circumstances should this document be used for construction or for establishing a boundary fence line. or *' '•PITH As -Built Survey of ...:.... Lot 1, Block 5 Prospect Heights Addition #1 rr.detic w`Vr er /I S •, NO.L6.4e46 •' �; I, Frederic Wagner, hereby certify that this Mortgage Inspection Survey was performed by me, or 3/17/2020 J_ under my direct supervision on March 2nd, 2020. 1- 11 it 5 I1lIpROFE5510NJxLL �.j0 ttttNt�������`` Frontier Surveys, LLC FRONTIER, 650 W. 58th Ave. Suite E Anchorage, Alaska 99518 907.460.1686 - info@frontiersurveys.com A"t5z PROFESSIONAL SEAL www.frontiersurveys.com