Loading...
HomeMy WebLinkAboutPTARMIGAN ROOST BLK 2 LT 12 MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 hftp://www.muni.org/onsite On -Site Wastewater Disposal System Permit Permit Number: OSP241362 Work Type: Septic Upgrade Tax Code Number: 02004280000 Site Legal Address: PTARMIGAN ROOST BLK 2 LT 12 G:3238 Site Mailing Address: 16300 SANDPIPER DR, Anchorage Owner: AREND JAMES C & MARGARET S Design Engineer: FORGE ENGINEERING This permit is for the construction of: 2 Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy Effective Date: Expiration Date Lot Size in Sq Ft: Total Bedrooms: OVA.: Dcimrtincttt 11 /5/2024 11 /5/2025 37659 ❑ Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Received By: '' Date: .� i s 2n Issued By: Date: 2 4 Community Development Department Phone: 907-343-7904 Development Services Division Fax: 907-343-7997 On -Site Water & Wastewater Program ON -SITE SEWER/WELL PERMIT APPLICATION Parcel I.D. 020-042-80 Property owner(s) James and Margaret Arend Day phone (907) 440-0663 Mailing address 16300 Sandpiper Dr, Anchorage, AK, 99516 Site address �� 16300 Sandpiper Dr, Anchorage, AK, 99516 Legal description (Sub'd., Block & Lot) Ptarmigan Roost, Block 2 Lot 12 Legal description (Township, Range & Section) Lot Size - 37,659 _Sq. Ft. Number of Bedrooms 4 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (ED all that apply) Absorption Field 0 Initial R Single Family (SF) RX, (w/wo ADU) Septic Tank EK Upgrade RX Duplex (D) ❑ Holding Tank R Renewal 1-1 Multiple Dwellings El Privy ❑ (SF and/or D) Private Well ❑ Water Storage EJ THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: Waiver Fees: '7'-/ Date of Payment: Date of Payment: Receipt Number: Receipt Number: Permit No. Waiver No. Permit App_'-'- '. :-'., c , October 16, 2024 MOA Development Services, On-Site Water & Wastewater Program 4700 Elmore Rd Anchorage, AK 99507 Subject: Ptarmigan Roost, Block 2 Lot 12 – 16300 Sandpiper Drive Septic system design Dear On-Site Services Engineer: The owner of the above lot has an existing 4-bedroom home on the property, so we are submitting this permit application for the construction of a new septic system. The attached site plan identifies the location of the home as well as the existing well and new septic location. No conflicts exist between this proposed system and any other well or septic system, whether on this lot or adjacent lots. The ground surface on the lot slopes steeply on the east and west sides of the lot. However, near the middle of the lot the slopes are much milder. Contours are shown on the site plan showing the grade and direction of flow. Downslope of the septic installation area there is a short section of slope that drops off toward the road at more than 46%. However, the section is very short with a drop of less than 10’, and the area is much flatter below that. The attached slopes profile shows that the dropoff will not cause any daylighting of septic effluent. Stormwater drainage will not impact this septic system. The new trench will be constructed parallel to the slope as much as possible. Wells on this and adjacent lots are shown. The new system will be a minimum of 100’ from all wells and surface water, and more than 5’ away from the septic tank. Please refer to the attached test hole log, plan and profile pages for the septic design. If this design is followed, there will be no adverse impacts to adjacent properties. Sincerely, Benjamin Schiller, PE Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP241362, Curtis Townsend, 11/05/24 x x x x x x x Benjamin Schiller CE 12592REGISTEREDPROFESSION A L E N GINEER 1"=30' CO - CLEANOUT 2CO - DOUBLE CLEANOUT FCO - FOUNDATION CLEANOUT FS - FLOW SPLITTER VALVE MH - MANHOLE MT - MONITORING TUBE SV - SEPTIC VENT TH - TEST HOLE LEGEND PTARMIGAN ROOST, BLOCK 2 LOT 12 FEET 0 30 60 SEPTIC PLAN 10/15/24 940 950 930 920 910 NEW 1250-GAL SEPTIC TANK LOCATE FCO AT INSTALLATION EXISTING 26' WIDE x 37' LONG, 6" EFF DEPTH BED TO REMAIN IN SERVICE FIND AND REPAIR ANY MISSING PIPES EXISTING TANK TO BE DECOMMISSIONED PER UPC (2) 50' LONG x 5' WIDE, 6" EFFECTIVE DEPTH ABSORPTION TRENCHES MIN 6' SEPARATION DV FS MT MT MT MT 2CO CO CO CO CO TH#1 10 ' U T I L I T Y E A S E M E N T 10' U T I LITY EA S EM E N T SA N D P I P E R D R I VE 20' UTILITY EASEMENT 4-BDRM HOME WELL w/ 100' RADIUSNEIGHBORING WELL RADIUS NEIGHBORING WELL OUT OF VIEWPORT >5' >10' PTARMIGAN ROOST B3 L3 WELL RADIUS Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP241362, Curtis Townsend, 11/05/24 PTARMIGAN ROOST, BLOCK 2 LOT 12 TYPICAL TRENCH SECTION (NO SCALE) NOTES: 1. GRADE AREA OVER TRENCH TO DRAIN AWAY 2. PROVIDE 3' OF COVER OVER TRENCHES AND 4' OVER SEPTIC TANK, OR 2' WITH 2" OF INSULATION 3. CHECK GROUNDWATER AT TIME OF CONSTRUCTION. IF LEVEL IS HIGHER THAN PREVIOUSLY OBSERVED, CALL ENGINEER IMMEDIATELY Benjamin Schiller CE 12592REGISTEREDPROFESSION A L E N GINEER DESIGN FACTORS:SYSTEM REQUIREMENTS: 600 GPD PEAK FLOW PERK RATE: 3.0 MIN/IN APPLICATION RATE: 1.2 GPD/SF 5' WIDE TRENCH SYSTEM 1250-GAL SEPTIC TANK BOTTOM OF TRENCH: 4' BELOW GRADE FLOW LINE ELEVATION: 3' 6" BELOW GRADE 600 GPD / 1.2 GPD/SF / 5' WIDE * 1.00 RED FACTOR [6" DEEP] = 100 LF TRENCH REQUIRED (100 LF SPECIFIED) 10/16/24 5' 4" PERFORATED PVC (HOLES DOWN) DRAINFIELD ROCK 6" 3' 6" GEOTEXTILE FABRIC 6" PROVIDE ADDITIONAL FILL TO ACCOUNT FOR SETTLEMENT Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP241362, Curtis Townsend, 11/05/24 0+00.00 0+50.00 1+00.00 1"=10' SLOPE CROSS SECTION SEPTIC TRENCH (TYP) Benjamin Schiller CE 12592REGISTEREDPROFESSION A L E N GINEER 46% AN G LE OF EF FLUE NT INF LUE N CE 3:1 MAX SLOPES PTARMIGAN ROOST, BLOCK 2 LOT 12 6.0 FEET 0 10 20 8/22/23 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP241362, Curtis Townsend, 11/05/24 LEGAL DESCRIPTION: PERFORMED FOR: DATE: PARCEL ID#: SOILS LOG AND PERCOLATION TEST 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 DEPTH (feet) TEST HOLE 1 DATE READING START TIME NET TIME (minutes) DEPTH to WATER NET DROP PERCOLATION RATE: (MIN/INCH) (inches)(inches) DATE OF MONITORING WAS WATER ENCOUNTERED? DEPTH TO WATER AFTER MONITORING IF YES @ WHAT DEPTH? 3.0 9/27 1 2 3 4 5 6 GP (POORLY GRADED GRAVEL) Professional Engineers Stamp: YES PTARMIGAN ROOST, BLOCK 2 LOT 12 9/27/2024 020-042-80 A+ HOME SERVIES 11:53 1 0 16 1' OB 30 Benjamin Schiller CE 12592REGISTEREDPROFESSION A L E N GINEER PERC TEST LOCATION TECHNICIAN: J. OPHEIM 7 0 16 11' 10' 10/4/24 COMMENTS: SITE PLAN 6 0 16 USCS SOIL CLASSIFICATION WAS VISUALLY DETERMINED 10/1/24 12:09 1 0 1610 6 0 16 5 0 16 12:20 1 0 1610 5 12 16 4 12 16 12:31 1 0 1610 5 0 16 4 0 16 12:44 1 0 1610 4 8 16 3 8 16 12:55 1 0 1610 4 5 16 3 5 16 7 1:07 1 0 1610 4 5 16 3 5 16 FILL OG OB GM (SILTY GRAVEL) Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP241362, Curtis Townsend, 11/05/24 PLOT PLAN AS BUILT —2L SCALE 1" = 40' GRID SW 3238 Project No J24-192 Al P.O. Box 210005 OG-MF.� L o n g & Associates, i n C. Anchorage, Alaska 99521-0005 202q— (907) 522-6476 oQo004p�O Professional Land Surveyors jonothanOlangsurvey.com o 0 F A kenOlongsurvey.com I hereby certify that I have surveyed the following described property: LOT 12, PTARMIGAN ROOST (Plat No. 71-214) Anchorage Recording District, Alaska, and that the improvements situated thereon are within the property lines and do not encroach onto the property adjacent thereto, that no improvements on the property lying adjacent thereto encroach on the surveyed premises and that there are no roadways, transmission lines or other visible easements on said property except as indicated hereon. Dated this the `— Day of TO at Anchorage, Alaska It is the responsibility of the owner to determine the existence of any easements, covenants, or restrictions which do not appear on the recorded subdivision plat. *....!......l..Ar-). . ... . ... .. o NAT G CIO, —9944. •AR •. ..• aQo 4�n �FfSSIONA� �� State of Alaska AECC963 Municipality of Anchorage Page / of~ DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744 On-Site Wastewater Disposal System and/or Well Inspection Report Nam~/,¢2~_~¢ ~. ~~ Wastewater System: ~New ~ Upgrade ~/ C~/D o¢~ ~. ~ ABSORPTION FIELD Phone: Nc. of ~rooms: ~ Deep Trench ~ ShaHowTrench ~Bed B Mound ~ Other Total DeRth from orig~al~rade: LEGAL DESCRIPTION SoilRating: ~ GPD/Sq. Ft. Lot: / ~ Block: ~ ~ubdivision: / Depth to pipe bottom fiom ordinal gra~e: Gravel depth beneath~e~ / Township: Range:~ ~~ Fill added above~,original~ ~grade:~,~ ~t.~ Gravel length: ~ ~ / Ft. Number of lines: I Distan6e betw~n Pines: WELL: ~New ~ Upgrade Gravel width: ~/ Ft. ~/ ~--~Ft. Clas~c~tion (Private, A,B,C): ~ Total Depth: Cased To: Total absorption area:~ Pipe mat~ria ~/~h Driller: / Date Drilled: Static Water Level: In~r~__~ ' ,Date installed: Yield: Pump Set at: Casing Height Above Ground: GPM Ft. Ft. TAN K SEPARATION DISTANCES CSept~c U Ho~din~ U S.T.~... TO Septic Absorption Lift Ho~ding Public/Private M~n~facturer: Capacity in gallons: Surface Lot /~ /~ ~ ~ Size in gallons: Manufacturer:~ Line CurtainDrain ~ ~ ~ /~, ~ ~ ~ump Mabel Electrical inspections performed by: Remarks: BENCH MARK Location and Description: ENGINEER'S SEAL Reviewed and approved b ~Date: ' ¢:' "::" "'" 72-013 (Rev. 9/91) MOA 25 Permit No. $W920040 2 2 Page of Municipality of Anchorage DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744 On-Site Wastewater Disposal System and/or Well Inspection Report PTARMIGAN ROOST, BLOCK 2, LOT 12 02004280 Legal Description: PID No.: CO1 C02 · ' FINAL GRADE NEW ~70.4 1250 GAL MT2 MTI C04 ~74' ISR ' ,, ~-- 69.7' ~x,_ 70.2, · 66.1' WATER FOUND NEW 1250 GAL SCALE f' = 40' 4 BDRM HOUSE I FOUNDATION SEPTIC TANK~ ,4.5' NEY/' BED FCO CO1 C02 CO CO C03 MT1 MT2 C04 20.0 53.6 28.5 63.6 29.3 64.2 130.3 I 65.2 142'3 I73'0 /4°-? / 58.8 /64.2 I85.0 [66.4 [77.8 72-013 A (Rev. 9/91 ) MOA 25 LOCATION OF WELL I ,STATE OF ALASKA DEPARI'MI~NT OF NATURAL RESOURCES DIVISION OF WATER WATER WELL RECORD LOCATiON/SI(ETCH: I DEPTH~ IVIF~SURED FROM:E]cas;n~ top ~ground surface ~OREHOI,E DATA." Material Type ~nd Color Depth From To WELL DEPTH; DATE OF COMPLETION Depth of hole: /6 ~' fL .......... i._ / ground surface ME'THOD OF D.R~LL!I~G; '~air rotary [] cable tool ~1 ¢:her US~- v.." WELL: ,b,~;dornestic ~ iq;gatiOn [.3 monitor C.r,,m::'Q S110K..U~ ~ ft. Diem: ~,% In. tO //~.tt WELL INTAKE OPENING TYPE; [-] open end ~ screened ~ pert, orated ~ open hole SOr;~ff:;~ TYPE: ................. Diem: $1ot'Mesh Size: ............ Length: G~VEL PACK TYPE: Vofum$ used: Depth tO top: GROUT TYPE: Volume: Depth: from ............... ft to. ft Duretlon: PUMPING LEVEL AND YIELD; _ / G ~ f~ ~fter _ flr~ pumping ~ opm PUMP INTAKE DEPTH: _ ft Horsep~oyver: WELL DISINFECTED UP'ON COMPLETION? REMARKS: PLEASE MAIL WHITE COPY OF L0'~ TO: DNR/DIVI$10N OF WATER PO BOX 772116 PAGE 1 OF 1 MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND HUMAN SERVICES /;- P.O. BOX 196650, 825 "L" STREET, ROOM 502 ANCHORAGE, ALASKA 99519-6650 ON-SITE WELL AND WASTEWATER DISPOSAL SYSTEM PERMIT PERMIT NUMBER:SW920040 DATE ISSUED: 3/25/92 DESIGN ENGINEER:S & S ENGINEERS EXPIRATION DATE: 3/25/93 OWNER NAME:AREND JAMES C & OWNER ADDRESS:5401 CORDOVA NO 204 ANCHORAGE, AK 99518 PARCEL ID:02004280 LEGAL DESCRIPTION: PTARMIGAN ROOST BLK 2 LT 12 LOT SIZE: 37659 (SQ. FT.) NUMBER OF BEDROOMS: 4 THIS PERMIT: 4 THIS PERMIT IS FOR THE CONTRUCTION OF: DISPOSAL FIELD /SEPTIC TANK / WELL SYSTEM ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH: 1. THE ATTACHED APPROVED DESIGN. 2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS 15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80). 3. THE FOLLOWING SPECIAL PROVISIONS. SPECIAL PROVISIONS: ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS PRIOR TO EACH INSPECTION. RECEIVED BY: ISSUED DATE: HEALTH AUTHORITY APPROVALS SEWER &WATER MAIN EXTENSIONS SEWER & WATER INSPECTION ENGINEERING STUDIES AND REPORTS WELL INSPECTION & FLOW TEST SITE PLANS ROAD DESIGN SOIL TEST PERCOLATION TEST STRUCTURAL & MECHANICAL INSPECTIONS ON SITE WASTE WATER DISPOSAL SYSTEM DESIGN ROBERT SHAFER, P.E. ROGER SHAFER, P.E. 31, 1992 CIVIL ENGINEERS (907) 694-2979 FAX 694-1211 Multiparty of Anchorag~ DEPARTMENT OF HEALTH AND HUMAN SERVICES 825 L Street P. 0., Box 196650 A~chorage, Alaska 99519-6650 REFERENCE: Septic Inspection Reports: Lot 13; Block I; Timb~rlan~ Park #1 Lot 12; Block 2; Ptarmigan Roost RECEIVED JAN 4 iD Municipality ot Anchorage ept. Health & Human Services Over last summer w~ performed inspections on the insta~tion of septic systems located on the abov~ referenced properties. AU of th~se systems were installed in a satisfactory manner and in accordanc~ with th~ permits issued by your offic~.~ However, to date, th~se r~main virtually undeveloped properties without foundations installed. Once foundations are installled w~ wi~ complete inspection reports with swing-ti~s tied into th~ corners of th~ house. The appropriate ~levation data can then §~ tied i~o a proper benchmark. Therefore, completed septic inspection reports for th~s~ properties are forthcoming.~ If you have any questions or comments pleas~ contact us. Sincerely, ROGER J.. SHAFER, P.E. RJS/tv 17034 EAGLE RIVER LOOP, SUITE 204, EAGLE RIVER, ALASKA 99577 HEALTH AUTHORITY APPROVALS SEWER & WATER MAIN EXTENSIONS SEWER & WATER INSPECTION ENGINEERING STUDIES AND REPORTS WELL INSPECTION & FLOW TEST SITE PLANS ROAD DESIGN SOIL TEST ROBERT SHAFER, P.E. ROGER SHAFER, P.E. February 25, 1992 CIVIL ENGINEERS (907) 694-2979 FAX 694-1211 Municipality of Anchorage DEPARTMENT OF HEALTH AND HUMAN SERVICES 825 L Street Anchorage, AK 99519-6650 REFERENCE: Ptarmigan Roost Subdivision, Block 2, Lot 12 We request you issue a permit to drill a well and install a septic system to serve the proposed 4 bedroom house on the referenced property. Two test holes were excavated and percolation tests performed on the property on May 20, 1992. The approximate location of the test holes are located on the attached site plan. The monitoring tubes within the holes have been checked and found to be dry on February 20, 1992. On May 27, 1991 there was water found at 7.5' and 9' This property has enough area for a septic upgrade which can be seen on the attached site plan. We do not anticipate any adverse effects on neighboring properties by the installation of the proposed septic system. If you have any questions, or require additional information for your review, please contact us. Sincerely, PERCOLATION TEST STRUCTURAL & MECHANICAL INSPECTIONS ON SITE WASTE WATER DISPOSAL SYSTEM DESIGN RJS/lsu 17034 EAGLE RIVER LOOP, SUITE 204, EAGLE RIVER, ALASKA 99577 /" ~-- 6'0' SCALE 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG m PERCOLATION TEST LEGAL DESCRIPTION: L~'~ ~- ~ ~ ~ t~Ar.~ Township, Range, Section: SLOPE SITE PLAN WASGROUND WATER ENCOUNTERED? ! s IF YES. AT WHAT L O DEPTH? p E Depth to Water After ~ I/ I Moniloring? -/ ~"~' Dale: 1 2 3 4 5 6 7 8 9, 10 11 12 13 14 15. 16- 17 18 19 20 Reading Date Gross Net Depth to Net Time Time Water Drop ~_ '?.-'-c:~ ,, (5'~/"4" .,t~ PERCOLATION RATE ~ '-'~1 (minutes/inch) PERC HOLE DIAMETER __ TEST RUN BETWEEN~ FT AND FT COMMENTS $ & ~ ~.. [~l 1,~ i [,,~ ~.,~. ~ ~ ~[,~.~ /~/ / ' · · 0. /// 17d3~. Ea,~]e River Loop Road No 2 / ~ PERFORMED B~® River, AlasEa g~S7~ ' ~~ : ' ~/-~ ~ CERTIFY THAT ~E~T WAS PERFORMED IN PERFORMED FOR: Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L' Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST LEGAL OESCRIPTION: ["1~" 1~ 'Z-- '"~"-/~ >jl~/~Township, Range, Section: 7 1 2 3- 4 5 6 7 8 9 10. 11 12 13 14 15 16 17, 18- 19- 2O .~...~ SLOPE ENCOUNTERED? IF YES, AT WHAT DEPTH? Depth to Water A~r Monitoring7 ~-~"~-~{ Date: SITE PLAN Reading Date Gross Net Depth to Net Time Time Water Drop ~r G:~---~-~ ~' ~.,-.'/DJ" ~" PERCOLATION RATE ~'- (minutes/inch) PERC HOLE DIAMETER TEST RUN BETWEEN "~ -- FT AND ~ FT COMMENTS ~ . S &SENGI,~EEEING .~ /~ / 17034 Eag,e River Loop Road" ///~ // ~ PERSORM~O ~ag~ ~:v=~, Al==k= 3~=7F*~o. 204 ~/ /~ CERT~SY THa~ffHI~EST~AS. PERFOaMEO ~N MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & HUMAN SERVICES Division of Environmental Services On-Site Services Section P.O. Box 196650 Anchorage, Alaska 99519-6650 343-4744 CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. # 02004280 1. GENERAL INFORMATION Complete legal description HAA # ~ f~,°l '~r'1.4~7t"~ Ptarmigan Roost'Subdivision,. Block 2, Lot 12 Location (site address or directions) 16300 Sandpiper Drive Property owner James C. Arend Day phone Mailing address5401 Cordova No. #204, Anchoraqe, Alaska 99518 Lending agency City Mortgage / Brenda Reynolds Day phone Mailing address 277-0809 Agent Day phone Address Un/ess otherwise requested, HAA will be held for pickup. NUMBER OF BEDROOMS: 4 TYPE OF WATER SUPPLY: Individual well xx NOTE: Community well Public water '" If community well system, .~rovide written confirmation from State ADEC attest- ing to the legality and status of system. 4. TYPE OF WASTEWATER DISPOSAL: Individual on-site ' Holding tank Community on-site Public sewer NOTE: If community wastewater system, provide written confirmation from State ADEC attesting to the legality and status of system. 72-025 (Rev. 1/91) Front MOA #21 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health Authority Approval application shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on the date of this inspection. $ & $ ENGINEERING Name of Firm _ . ii0;~4 Eagle River L~op~d l~¢, 204 Address, Eagle River, Alaska~..//.~/~9~/~7 Engineers signature Phone DHHS SIGNATURE ~¢,_~z~.L~ ~" Approved for _ Disapproved. Conditional approval for bedrooms. bedrooms, with the following stipulations: Additional Comments The Municipality of Anchorage Department of Health and Human Services (DHHS) issues Health Authorit~ Approval Certificates based only upon the representations given in paragraph 5 above by an independent~ professional engineer registered in the State of Alaska. The DH HS does this as a courtesy to purchasers of homes ~ and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHHS do not conduct inspections or analyze data before a certificate is i,ssued. The Municipality of Anchorage is not i~7 ~ifi~il fBTcrk el rc~ r#1~Or OmissiOns in the prOfessiOnal engineer s wOrk' . Municipality of Anchorage Department of Health and Human Services HEALTH AUTHORITY APPROVAL CHECKLIST Legal Description: -'"~z.~-~ ~_/ L~-'/- /'~- Parcel I.D. A. Well Data Well type Log present) Total depth Sanitary seal'N) /~ k/'-fd, 7':~ If A, B, or C, attach ADEC letter. ADEC water system number Date of test Static water level Well flow Pump level1 Date completed '~¢' J~'~l ~1'~ Cased to FROM WELL LOG Wires properly protecte(~N) AT INSPECTION / g.p.m. / Driller ¢r L-~ Casing height JCuNICIPALtTY OF ANCHORAGE ENViRoNMENTAl' SERVICES DIVISION AUG ~ 0 i993 O' ECEIVED SEPARATION DISTANCES FROM WELL TO: Septic/holding tank on lot J Absorption field on lot [ Public sewer main Sewer service line ; On adjacent lots ; On adjacent lots Public sewer manhole/cleanout Petroleum tank f'--[ [~-- WATER SAMPLE RESULTS: Coliform ¢ Nitrate Date of sample: ~/,.~/~'~ B. SEPTIC/HOLDING TANK DATA Date installed Date of pumping Collected by: Other bacteria "~r' [ ¢"~ l~'~-- Tank size I'~'~ /'~-~U-~ompartments Foundation cleanou~)~ Depression (Y~ tested (WN) ~ : Alar~ ~ Pumper ~ ~1~ ~ SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK TO: Well(s) on lot j/~/ On adjacent lots To property line l (2'--~ Absorption field ~ '4-- Foundation Surface water/drainage Water main/service line 72-026 (3/93)* Front CONTINUED ON BACK PAGE C. LIFT STATION Date install~ Manufacturer / Size in gallons ~ Manh~ Vent (Y/N) ~'~~On'' level at _ .--'"'"'"/ "Pu'mp ;fi" Level at MHi:ehtsWaMteorAal~recmt;:Velca, codes (Y. JJ4~~ Cycles tested SEPAR~T~OM LIFT STATION Well °_~tOt~ On adjacent lots ~ Surface water Total absorption area Date of adequacy test D. ABSORPTION FIELD DATA Date installed '~-'-"-~ [ Length ~ ~-- / Width Water level in absorption field before test Soil rating (GPD/Ft2) ,~,,,~ ~ / Gravel thickness ~'~, Cleanout present (~N) Results (pass/fail) . Peroxide treatment (past 12 months)/(~2 SEPARATION DISTANCE FROM ABSORPTION FIELD TO: Well on lot ~ Z~F~ I To building foundation ~'~'~/ On adjacent lots Surface water Curtain drain System type ~ ,~-~'~ Total depth .~A / Depression over field (Y/~ P for '~ Bedrooms After test ~//~L. If yes, give date ,~.///~- - On adjacent lots I ~ ' --f- Property line To existing or abandoned system on lot Cutbank I,.1,~-1- ¢ Water main/service line Driveway, parking/vehicle storage area '+ E. ENGINEER'S CERTIFICATION Signature .. Engineer's Name Date I certify that I have checked, verified, or conformed to all MOA and HAA guidelines in effect S & S ENGINEERING //~~~ 17034 Eagle River roop//~g{~O. 204 Eagle River, Alaska 9~/,{i~/," ' -' HAA Fee $ i.~)~ -~)~) Date of Payment Receipt Number 72-026 (3/93)* Back / Waiver Fee $ Date of Payment Receipt Number 1g~ -' :~; 1 'CHRIS AR~ND PHOTOGRAPHt' S+S Engineering Attn: Lynda ~e: ~t 12', Block 2 Ptarmigan F~: 694-1211 CHRIS Roost P H 0 t 0 .... p-~. ::IICI ,j. To ~vhom it pay concern: The septic on the abov,e referenced properly was installed' in the zt~'mmer of 1992. The.houSe is being built now and the septic system has not beeh'in use. , Sincerely, .. ~rames C. Arcnd Hom,'ebuyer