HomeMy WebLinkAboutRABBIT CREEK VIEW & HEIGHTS BLK 1V LT 6ARabbit Creek
View Heights
Block i V
Lot 6A
#020-521-11
Flowline Construction LLC
PO Box 102221
Anchorage, AK 99510
907-748-0878
October 9, 2023
Municipality of Anchorage
Attn: Development Services- Onsite Site
632 W 6th Ave
Anchorage, AK 99501
Subject: Decommission Septic Tank @ Lot 6A Jamie Dr- RABBIT CREEK VIEW & HEIGHTS L6A 131V
Dear Sir/Madam:
This letter is in response to your request to decommission the septic tank at the above location.
Flowline Construction Llc recently conducted a thorough search on the property in an attempt to
locate the septic tank. Unfortunately, we were unable to find it. We did, however, find several
standpipes, two of which we identified to be consistent with the placement of the tank based on
the installers sketch. We also located the drainfield stand pipe. We proceeded to dig down to the
bottom of the septic tanks pipes. We discovered that the septic tank was absent. The pipes were
placed to make the appearance of a tank but terminated into the soils. It appears the tank had
been removed with the pipes placed back into the ground as a ruse. During our investigation, we
noticed a significant dip in the area where the septic tank should have been located. This led us
to speculate that the septic tank had already been removed and backfilled.
We believe that the property is free from any septic tank.
Sincerely,
Noah G Groskreutz
Flowline Construction Llc
u nl' el' p a t y
Anchorage
POUCh 6-650
ANCHORAGE, ALASKA 99502-0650
(907) 264-4111
TONY KNOWLES,
MAYOR
DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION
October 17, 1983
Rick Daniels
SRA 4074-B
Anchorage, AK 99507
Subject: L6 Bl Rabbit Creek View
Dear Mr. Daniels:
This Department has reviewed the information regarding the subject lot.
The soils test submitted to this office shows two test holes and no
evidence that ground water was encountered down to 12 feet. A permit
was issued by this Department giving the specific design specifications.
Pyramid Excavating installed a system, which was inspected by S&S
Engineers and they submitted an as -built to this Department. This as -
built shows the trench depth to be deeper than the permit specifica-
tions, however, a note by the inspector stated that the overlaying
terrain to the south caused this change. Also, on the inspection as -
built there was no mention of water being present in the system's
installation.
Mr. Robinson has talked with S&S Engineers and there appears to be water
in the sewer system, plus the drainlines appear to be installed so they
run up-slope from the tank. Another test hole was installed in the
area of the trench by Alaska Environmental Control Services and after a
monitoring period ground water was at 8 feet.
Based upon all the information submitted to this Department we can not
accept the as-builts for the on-site sewer installation as installed.
In addition further research may be needed before installation of another
on-site system can be installed, and/or the other alternative may be
that only a holding tank can be installed. Before any construction is
undertaken, permits will need to be obtained from this Department.
If you have any further questions, please contact Mr. Robinson or myself.
Sincerely,
Cory Willis, R.S.
Acting Sewer and Water
Program Manager
CW3/p/EH
z
t'ulmit 6v®L> ����
P41/lelp— low
7a,04Z
lej 4,.a4 J--)eU
A&W
7125 OLD SEWARD HIGHWAY • ANCHORAGE, ALASKA 99502
September 15, 1983
Pyramid Excavating
Attn: Mr. Dan Thompson
1048 W. Int -1 Rd., Suite 103
ANchorage, AK 99502
Re: Rabbit Creek View Subdivision, Lot 6, Block 1, Rick Daniels Property Septic:. System
Gentlemen:
Our involvement in the construction of a septic system at the subject property has
been as follows:
1. On July 22, 1983 Mr. Bill Evans, of our office, performed a percolation test at a
location 35 feet south of the proposed house site. The percolation test indicated that
the silty material encountered would not support a septic system.
2. On July 28, 1983 Mr. Evans returned to the site and performed a second percolation
test at a different location on the lot. The second test indicated an acceptable
percolation rate. The results of the percolation test were submitted to the
Anchorage Municipality, and a permit was issued to build the septic system on
August 2, 1983.
3. The septic system was constructed and Mr. Evans inspected the system as the work
progressed. The inspection form was completed and submitted to the Municipality.
4. Subsequent to the successful completion of installation of the system, a period of
rainy weather occured. Surface water moved downslope across the lot, and flooded
the septic system and the excavation for the house foundation.
5. After inspection and a brief analysis of the problem, it was determined that the
solution to the water problem would be cost -prohibitive.
6. In summary, a passing percolation test was performed, the Anchorage Municipality
issued a permit, and the system was successfully and correctly installed. After the
system was put in, changed conditions occured due to weather. The changes(
"'.'�ondition could not have been anticipated. Even had the possibility of the surface:..
water problem been suspected before installation, it is likely that the owner would
have taken some risk to install the system.
WASILLA ANCHORAGE SOLDOTNA
(907) 376-3770 (907) 349.6561 (907) 262-9534
Pyramid Excavating
Page 2
Should you have any questions regarding this matter, please do not hesitate to
contact us at 349-6561.
Sincerely,
David A. Stanley
Geotechnical Manager
DAS:sc 4
Job 3738
72-013 (Rev. 3/78)
MUNICIPALITY OF ANCHORAGE 1.
DEPARTMENT OF
HEALTH & ENVIRONMENTAL PROTECTION
' ENVIRONMENTAL
ENGINEERING DIVISION
825 L Street - Anchorage, Alaska 99501 Telephone 264-4720
ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION
REPORT
NAMED
PHONE
e! NEW
TA M ( YC.C__. -
'Ci� ��I�IC_l�
�f
`�-1�
El UPGRADE
MAILING ADDRESS
1ATERIJAII
L A rR'P' 1 .r S;UI 103 Arco A k w -c2
LEGAL DESCRIPTION
L,o% 6 BC C'C- J-
f CJZC-GK V I W .SU. DIV
B! og)
LOCATION
NO. OF BEDROOMS
®N SAmliil AVE/UVE
01 F CLARKS ROA
DISTANCE TO:
Well i ���
Absorption area
0
Dwelling
PERMIT NO.
�0•,
U Y
i
_
1.- ZManufacturer
w
/� ,�—
Rc—
Material _ _
STEE
No. of compartments
la-
CS
L
N
Liqc arty in gallons
C �9
IF HOMEMADE:
Inside length
NA
Width
� '
Liquid depth
IVA
DISTANCE TO:
Well
Dwelling
PERMIT NO.
0z<
za
ManufacturerMaterial
Liquid capacity in gallons
DISTANCE TO:(1
Well% 00+
Foundation/
Neares Int Iine�
PER�4�T-AVO.
W =
LL z
No. of lines
�n gtthof ach Ii e
Total len h o linesf,
Trench w�h��µ
Distance betrinJjngs
�Zw
,
% jj
Q F
Top the t finish
Material beneath tile
Total absorption
o
of grade
c. ' ,
effect' area
O
�' r<iS'H �-✓L -3.S 4,Onches
r Z 0
Length
Width
Depth
PERMIT N. ` �~ �"
-- F Af
Qa I—
W d
Type of crib
Crib diameter AIACrib
depth
Total effective absorption area ((�� vF p, °®opO°°OGo-
h ,a 0 0 °o Q�
y
DISTANCE TO:
WellLu
Building foundation
Nearest lot line
€:;
J
Class
Depth
Driller
Distance to lot line
P � -
JA
44
�
DISTANCE TO:
Building foundation
Sewer line IVIV
Septic tank
q•s
18`3 H -E o
(�
OTHER
M�
PIPE
MATERIALS
Sfi��z .2 i1 -
�� V
\ ..� ".T
SOIL TEST RATING
\
Z
J
INSTALLER
NMnA(D ExcAV AI -W
_
1
REMARKS
'%�E C H DC -PTO IIVC?E E3
O
rku cc fru ��,►
�� � sk 1�
S - TO aVE L1 aV -- G- 2/t1
AS'
7q
Z. 3 V 1jG R Se W G2 PA IS
1= -t
_
� a
PIPE CLGANOM 6 &Aj6 OF
&A, LINE
,>
17 CaIU SEPTic [
�
&UE C- MOT
I* N
APPROVED
DATE LEGAL
SLO
72-013 (Rev. 3/78)
TYPE OF SOIL AB_,ORPTIT N SYSTEM I E, : TRENCH
i'iAY1 I i'ii_ H NUMBER OF BEDROOMS = _ SOIL RATING &SQ FT/ BR) = 287
THE REQUIRED SIZE OF THE SOIL ABSORPTION SYSTEM I S :
n $ R0i 0- E? d--0= 1=1 J -I = -1 : Qa CB FR FA N? E= L iL-n F F=° -�` -ii — -:9 -
THE LENGTH DIMENSION I THE LENGTH &IN FEET) OF THE TRENCH OR DRA I NF I ELD.
THE DEPTH OF H TRENCH CH O R PIT IS THE DISTANCE BETWEENd THE SURFACE OF THE
GROUND D AN•, D THE BOTTOM OF THE EXCAVATION 0N FEET).
THERE IS NO SET WIDTH FOR TRENCHES.
THE GRAVEL DEPTH IS THE MINIMUM DEPTH OF GRAVEL BETWEEN WEEN THE OUTFALL PIPE
AND THE BOTTOM i iF THE EXCAVATION I N•d FEET).
a--: E= a -q i,_n 11: m iii E > in E" 9=- -T TL C_ -7- 1=1 hi F -T _„+, 1 no, a 7 = _!L C --u C --n C-1 a:3 �_-,fl 9_ L_ a_n F -"if
PERMIT APPLICANT HAS THE RESPONSIBILITY TO INFORM iF: M THIW DEPT= RTHEN•dT DURING THE
INSTALLATION INSPECTION+i` OF ANY WELL_ ADJACENT ACEN'dT Ti i TH I _. PROPERTY AND THE
NUMBER OF RESIDENCES THEN THE WELL WILL SERVE.
— — — E-„ 10 > F=" E= C::_ _6_' g 0011141 d=f1 FZ E= F_ ER= C -A 9_6 _+ ice' F= E::-1 — —
BA KF I LL I N• G OF ANY SYSTEM WITHOUT FINAL INSPECTION AN• D APPROVAL BY THIS
DEPARTMENT WILL BE SUBJECT TO PROSECUTION.
MINIMUM DISTAN'CE BETWEEN A WELL AND AN'd'T ON-SITE SEWAGE DISPOSAL SYSTEM I
iOO FEET FOR H PRIVATE WELL OR 1.50 TO 200 FEET FROM A PUBLIC WELL DEPEN DIN 13
UPON THE TYPE OF . PUBL I C WELL.
MINIMUM DISTAN'dCE FROM Ei PRIVATE WELL TO H PRIVATE SEWER LINE IS 25 FEET AND
TO A i .ilMM iN•:!ITY _,EWER LINE I E 75 FEET.
OTHER REQUIREMENTS MAY APPLY. SPECIFICATIONS AND CONSTRUCTION DIAGRAMS ►= RE
AVAILABLE TO INSURE PR iPER INSTALLATION.
1 CERTIFY THAT
i: I AN FAMILIAR WITH THE REQUIREMENTS F O R ON-SITE SEWERS AND WELLS AS SET
FORTH BY THE MUNICIPALITY � �F ANCHORAGE.
2: I WILL INSTALL THE SYSTEM IN ACCORDANCE WITH THE CODES.
: I UNDERSTAND TH_: - - �I�N•d-- S I TE SEWER SYSTEM MAY REQUIRE ENLARGEMENT IF THE
RESIDENCE- I=, F:EW »I OELEF u TO f I r,iCLi = N' L3 --..'E THAN BEDROOMS.
� �.,!,,�,;,�•�-tet � �, �+r � �,
APPLICANT RICK DAN•+iI.ELS CJ C1
bon
ISSUED �)A� E-----_�_.__SSSS 1
01---------
�:t
DEPARTMENT L
HEALTH
MN D, Ei'•dV I RON•dMEi' i T HL , I f T EC :I( I ON
PC) V
a25 5 - L ••
STREET,
ANCHORAGE,
AK. 99501.
264-4720
PEI 01 _ ..,;
4 n • HEE
4-1 n- 11 :
8=` EE ((= .k 6
PERMIT
NO. K 82071.7 .
APPLICANT
RICK DANIELS
SRA 4074-8
99507
688-2119
LOCATION
JAMIE RD L6 B1- RABBIT
CREEK VIEW S/D
LEGAL
T •i iN•d R .W SECTS
LOT T _+IEE x•74.2:_
Sf-'.i_iM=RE FEET
TYPE OF SOIL AB_,ORPTIT N SYSTEM I E, : TRENCH
i'iAY1 I i'ii_ H NUMBER OF BEDROOMS = _ SOIL RATING &SQ FT/ BR) = 287
THE REQUIRED SIZE OF THE SOIL ABSORPTION SYSTEM I S :
n $ R0i 0- E? d--0= 1=1 J -I = -1 : Qa CB FR FA N? E= L iL-n F F=° -�` -ii — -:9 -
THE LENGTH DIMENSION I THE LENGTH &IN FEET) OF THE TRENCH OR DRA I NF I ELD.
THE DEPTH OF H TRENCH CH O R PIT IS THE DISTANCE BETWEENd THE SURFACE OF THE
GROUND D AN•, D THE BOTTOM OF THE EXCAVATION 0N FEET).
THERE IS NO SET WIDTH FOR TRENCHES.
THE GRAVEL DEPTH IS THE MINIMUM DEPTH OF GRAVEL BETWEEN WEEN THE OUTFALL PIPE
AND THE BOTTOM i iF THE EXCAVATION I N•d FEET).
a--: E= a -q i,_n 11: m iii E > in E" 9=- -T TL C_ -7- 1=1 hi F -T _„+, 1 no, a 7 = _!L C --u C --n C-1 a:3 �_-,fl 9_ L_ a_n F -"if
PERMIT APPLICANT HAS THE RESPONSIBILITY TO INFORM iF: M THIW DEPT= RTHEN•dT DURING THE
INSTALLATION INSPECTION+i` OF ANY WELL_ ADJACENT ACEN'dT Ti i TH I _. PROPERTY AND THE
NUMBER OF RESIDENCES THEN THE WELL WILL SERVE.
— — — E-„ 10 > F=" E= C::_ _6_' g 0011141 d=f1 FZ E= F_ ER= C -A 9_6 _+ ice' F= E::-1 — —
BA KF I LL I N• G OF ANY SYSTEM WITHOUT FINAL INSPECTION AN• D APPROVAL BY THIS
DEPARTMENT WILL BE SUBJECT TO PROSECUTION.
MINIMUM DISTAN'CE BETWEEN A WELL AND AN'd'T ON-SITE SEWAGE DISPOSAL SYSTEM I
iOO FEET FOR H PRIVATE WELL OR 1.50 TO 200 FEET FROM A PUBLIC WELL DEPEN DIN 13
UPON THE TYPE OF . PUBL I C WELL.
MINIMUM DISTAN'dCE FROM Ei PRIVATE WELL TO H PRIVATE SEWER LINE IS 25 FEET AND
TO A i .ilMM iN•:!ITY _,EWER LINE I E 75 FEET.
OTHER REQUIREMENTS MAY APPLY. SPECIFICATIONS AND CONSTRUCTION DIAGRAMS ►= RE
AVAILABLE TO INSURE PR iPER INSTALLATION.
1 CERTIFY THAT
i: I AN FAMILIAR WITH THE REQUIREMENTS F O R ON-SITE SEWERS AND WELLS AS SET
FORTH BY THE MUNICIPALITY � �F ANCHORAGE.
2: I WILL INSTALL THE SYSTEM IN ACCORDANCE WITH THE CODES.
: I UNDERSTAND TH_: - - �I�N•d-- S I TE SEWER SYSTEM MAY REQUIRE ENLARGEMENT IF THE
RESIDENCE- I=, F:EW »I OELEF u TO f I r,iCLi = N' L3 --..'E THAN BEDROOMS.
� �.,!,,�,;,�•�-tet � �, �+r � �,
APPLICANT RICK DAN•+iI.ELS CJ C1
bon
ISSUED �)A� E-----_�_.__SSSS 1
01---------
�:t
SOILS LOG
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION PERCOLATION
TEST
825 L. Street, Anchorage, Alaska 99501 264-4720
SOILS LOG PERCOLATION TEST OA 5Tq,3 0.24 -
PERFORMED FOR: R; - k Q,Fn, c I s DATE PERFORMED:— 13 i /,q,3
LEGAL DESCRIPTION:
-,Sub,
DEPTH SLOPE Z'i[TE PLAN
IF E E T)
2
3
4
5
6
7
8
9
10
11
12
13
14-
15-
16-
17-
18 -
19-
20 -
5P
4-
15 -16-
17-
18-
19-
20-
5P
S,,,dy, Si
Few
J_
Fe , 9;,: 1.s (,41L )
WAS GROUND WATERS
ENCOUNTERED? - ye,5 L
0
P
nci
IF YES, AT WHAT 91311$3 - Is, E
DEPTH?
C_r
4,-r f A
Reading
Date
Gross
Time
Net
Time
Depth to
Water
Net
Drop
PERCOLATION RATE
(millutes/inch)
TEST RUN BETWEEN FT AND--""FT�
IA netrc Avie On
Rr0RMEDBY: _(".C'11r),.',,, CERTIFIED BY:
(6/79)
DATE:
7125 OLD SEWARD H\4'Y. ( ,.
_ ENGINEERS. i[C. ANCHORAGE, ALASKA 99503
S 349-6561 'rrall ntlr7N
SOILS LUG f'Efi(:OI-A1ION r�sl 3 1BELRoorn
- N j±_ „n1C I•Flrl rrltr_a�:ll /Z ��J ..
/.'f T7- �J - r '
I.LCn, I7CSCi+I� TrUN .(��s�?— i —�LtK J1 I'til��T�E�K UIGy� TSS? my IV SIGN
,' T fd ,
trey 0-2•001;&ANic MATIERiAL
3
O-�
2.0 12.0 BLUE &RAY 5ANcbY
S+uT w/ SGIhE 6?F,VE4, r ORL.Y
r
r t?ADED-MOSTLY F 7NES ✓r COA U S
MOIST, CC Ht 51Vt, NON -A AST, G,
o, Hrir?h MCKEP, SCA—,1E—RED
C0B13LE
ti 3�
•�
�
7
.Q
c
M
Imo.
l\lY ~ �l 2
C � G
'
S
,8
�4
E
20
u�
NOT To 5cAi-L=
t:nSGROUND V:nTERS
ENCOUNTERED' )/� _ - O
1F YCS AT WMinT
(_
VrDIN iJ[l Dcpth 10 _- {ienO, nr) Clatr ....
!o Ilk+Z' ! I• !,� .� M . n . !I / .
-20
c I I l: GS 5 ro,rt. �'b
JOHN E. SWANSON; �R� —� �- -- - i I : r0 S s/,b..
s •.°• V834 -E
Fq "°•�...?t°° Fes' �� � J i � 55 � �v,rn. J. r
-
�► pROfES510hP �j� J� v
PE RCOLr TIl']N F+r.TE
TES: ttUr; (I(T.:(Cr. _—�.� (T�
T—
T
InJ LCl� r�— C[ I t t r f I t t7 u Y ---
PERrOFlr.A(O By
DXTE
z'Ll LIA. M le A VE.
t^ND 5W
VASS CA?
v
kaf 5 b a
Ouse
/o ` 4r1'14tTY EASEMt✓/�(i�
�Oso�sry
u� _
{-5774
6 , 4�
0 hereby certify that i have surveyed the following
described property:
LOST & SL01-1K I PA-Ssl-r 6Z5EK. VIEW szj&D.
as recorded in the Anchorage Recording Precinct,
Alaska , and that the improvements situated
thereon are located as shown in this plot,
vWN. 114.5. M. PLOT PLAJ F8. AS-sutcT ;lt l
GV -v. ci iC . NGfN 1Nc� GoMPAN Lo -r 6 , &L.oc.K 1 Gr'tD: F7LAT70-15
PATS: 7/Its/s3 i P2o�tEcTt4o.
DATS1
P'X0688 RA9SIT C -Z6 k VIEW SUGO.
ANe W,�OAAGS, AIC. �Ig51 i 34S -
G 7�efa. t~!n l of 1
Jule G; 1977 Derr,''Ut ;i7i:272
Mir. William R. Robe � s
Star Route A Lox 441
anchorage, Alaska 99507
Subject2 Permit Expiration
Dear Mir. Roberts
A permit issued by this department for well and/or on-site
sewer installation on Lot 6 s3 -lock 1 Rabbit Creek View
Subdivision has expired since the issue date exceeds one
(1) Year.
In the event you still elan to install the well and/or
on-site sewer system, a new permit is required. The original
soil test may be used to'obtain a current permit.
if the well has been drilled, a well log should be sent
to this department to document the installation_ date.
If you have any questions regarding the above matter, please
do not hesitate to contact this office immediately at 279-
2511, extension 224 or 225.
Sincerely,
Les N. Buchholz, R.S.
Sanitarian
LNIB .1 j h 1 --,
,
����1��� .��1��� ��� ����� �� - � �/ ��//
DEPHRTMEN � HEALTH AND ENVIRONMENTAL oOTECTION
2510 E. TUDOR RD., ANCHORAGE, HK. 99507
276-2221
K���--���-FF- ��G��J E—= F-,-" ����F���1 -�
PERMIT NO. ( 76272 )
APPLICANT STH BOX 441 NONE
LOCATION OFF LARK ROAD
LEGAL L6 B1 RABBIT CREEK VIEW SID LOT SIZE 45000 SQUARE FEET
TYPE OF SOIL HBSORBTION SYSTEM IS: TRENCH
MHXIMUM NUMBER OF BEDROOMS = ] SOIL -RATING (SQ FT/BR)= 125
^
THE REQUIRED SIZE OF THE SOIL ABSORPTION 5YSTEM IS:,
`
THE LENGTH DIMENSION IS THE LENGTH <IN FEET) OF THE TRENCH OR DRAINFIELD.
THE DEPTH OF A TRENCH OR PIT 15 THE DISTANCE BETWEN THE SURFACE OF THE
GROUND AND THE BOTTOM OF THE EXCAVATIONAIN FEMN).
THERE 15 NO SET WIDTH FOR TRENCHES. _7
THE GRAVEL DEPTH IS THE MINIMUM DEPTH OF GRAVEL BETWEEN THE OUTFALL PIPE
AND THE BOTTOM OF THE EXCAVATION (IN FEET).
!EE-
BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSINTION AND APPROVAL BY THIS
DEPARTMENT WILL BE SOBJECT TO PROSECUTION.,
MINIMUM DISTANCE BETWEEN A WELL AND ANY Chy SITE SEWAGE DISPOSAL SYSTEM IS
100 FEET FOR A PRIVATEAELL OR 200 FEET qbR A PUBLIC WELL.
SPECIFICATIONS AND CONSTRUCTION DIAGRAM /ARE AVAILABLE TO INSURE PROPER
I -IF flD F -R �ri'41E- �UEE'F:�F? L----.
\
I CERTIFY THAT ,
1: I HM FAMILIAR WITH THE REQUIREMENTS FOR ON-SITE SEWERS AND WELLS AS SET
FORTH BY THE MUNICIPALITY OF ANCHORAGE.
2: I WILL INSTALL THE SYSTEM IN ACCORDANCE WITH THE CODES.
]: I UNDERSTAND THAT THE ON-SITE SEWER SYSTEM MAY REQUIRE ENLARGEMENT IF THE
RESIDENCE IS REME) ED TO INCLUDE MORE.THAN -1 BEDROOMS.
SIGNED: ----- _L_-�_-- _ ---------
APPLICANT— 4ILLIAM R ROBERTS
ISSUED BY___ _-L~��-�� DHTE___������-L�{��__
�� ��
-
_"AMA; 'y
Performed forR� S C3tt: L CJ C -+>L
W+! LL I ROB_ERTS
Legal Description :RABBIT CREE-K VIEW SUBDIVI
This form reports:— Soils log -x: —'---
Depth
Feet
l-
T 2 -
3 -
�J
N`4=.
v
6 -- /
OVERBURDEN( DARK PEAT)
BROWNISH CLA-YEY LOAM
GRAYISH CLAY (7350,
S$11,.TY SAS•D AND GRAVEL
(225)
GRAYISH SAND WITH SILT
(250)",
cfl LAT -1 o N T�sT
Performed MAj 2LF 1 6
1.0N�-
Percolation test -`
STRATIFIED SAND AND GRAVEL
(125)
S/0
Was ground water encountered? N'6' _ _ If ves, at what depth?
-- ( NOTE: GROUND APPEARED FROZEN AT 2-6 FT. LEVEL; ICE WATER SEEPING DOWN)
Reading Date Gross Time _ Net Time gD-'�pth to Water
Net Drop
--------- -- -------- ----=------------- 1--- — -- -----... ----
Pe--rco—lation----rate minute.
i'roElosed .instal iat
Ion.- Setvbaacje Pit _ Drain Fieri
;jepth of Inlet _ _ _ 3Ueptlltto bortom of pit or- Lrellci, _---- - _---------
COHIIJEiiTS:8 BELD_W___&'__DEPTH LE-V_ELr_GR.011.ND..._I-S-.P-OB-O-US_-E-MOUG-M_T-O.AB_S.O.F_.BFIDL_F_
_
SE_ E-FL_U-ENT AT
RATE OF 125 SQ.FT. PER BEDROOM.UFLUENT"- ELEVATUON, PIT OI'} -SRAIN FIELD, SHOULD BE NO
_H IGHER .THA.N _8.FT,_B.ELOW_ GROU1,I_D_ .LEVEL.-ABD_V.E_E_PT}i--U.S. NOT- RE.C-O-M.MENDED.- .
Perforr ed Ly: LEO M. THOMPSEN -- - f.C'r-tl Fi"(i L,y:, 'Da Le: JUNE! 1976
li(1 040 (61 %4) __.. ..