Community Development Department Page 1 of 3
On-Site Water and Wastewater Program
4700 Elmore St. • P.O. Box 196650 Anchorage, AK 99519-6650 - http://www.muni.org/onsite • (907) 343-7904
ON-SITE WASTEWATER INSPECTION REPORT
W-37
Permit Number: OSP151232 PID Number: 020 ❑ New ❑✓ Upgrade
Name:
Jacques Boutet and Donna Gryder-Boutet
ABSORPTION FIELD
❑ Deep Trench El Shallow Trench E] Bed ❑Mound
Address
9043 Snowy Owl Lane Anchorage, AK 99507
❑ Other
Phone
Number of Bedrooms
Soil Rating
Total depth from original grade
4
GPD/SF
Ft.
LEGAL DESCRIPTION
Depth to pipe invert from original grade
Ft.
Gravel depth beneath pipe
Ft,
Subdivision Block Lot
Rabbit Creek View & Heights 4V 4A
Fill added above original grade
Ft.
Gravel length
Ft.
Township Range Section
Gravel width
FL
Beds: Number of Lines
Distance between lines
Ft
SEPARATION DISTANCES
To
Septic
Absorption
Holding
Sewer
Total absorption area
Number of trenches
Dist. between trenches
From
Tank
Field
Lift Station
Tank
Line
Ft'
Ft.
Well
>100'
>100'
>100'
>75'
>25'
TANK O Septic ❑ S.T.E.P. ❑ Holding ❑ other
Manufacturer
Anchorage Tank
Capacity
1,250Ga1.
Surface water
>100'
>100'
N/A
NIA
Material
Number of compartments
Lot Line
>5'
>10'
N/A
N/A
Steel
Two
NA
Foundation
>5'
>10'
NIA
N/A
LIFT STATION
Manufacturer
Capacity
Curtain Drain
None
Noted
Gal.
Remarks Tank Only Replaced Under This Permit.
Pump on level at
in,
Pump off level at
in,
High water alarm at
in.
Existing Tank Decommissioned in Accordance With
Municipal Code.
Pump make and model
Electrical Inspections performed by
Installer
PIPE MATERIAL House to tankD3034 Tank to D3034
drainfeld
G&R Excavating
Drainfield Co/MT
Inspector W Roberts
BENCHMARK (Assumed elevation) 100.Oft
Inspectionr
1 8/11/15 8/12/15
Location and description
dates: 2na
30 8/14/15 4'"
Back Upper Deck.
COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL
:n.A0,q► W i
OF q
0P'�� `�S`��,
Conditional Approval: Date
07,
.... ....c
— --
MICHAEL E. ANDERSON :a- Av
CE-4381=�
Approved Date 81 q�/,
14% j""�����
Inspection Keport_1-1-12.aeo
r
Permit Number, OSP151232
I
LOT 4A, BLOCK 4)( V
RABBIT CREEK V & H
I
LOT 2A 30,761 SF
-I -----------------------
N 89°37'15"E 187.70'
I _
I
I 10' UTILITY EASEMENTS
I C2 j z4
•
st QOfZ I S2
p
p i
CO i
Ui FCO
i
Existing
Absorption ,� Four
Bed Bedroom
Home
rn
NOTE:
Existing Septic Tank
Decommisioned in #S256.6'
B
Accordance with 9' 68.9'
Municipal Code.
69.7'
I
LOT 4A ®Existing
I
30,761 s.f. Well
I GAS 10'x20'It
NATURAL
\
WOODEN FENCE � �
6=:1'3iSff.'i&7riE:1 Ai
I
LOT
6A
LEGEND
.:,
OF q( ���
••...�51�+
S1 —
Septic Vent
..�P,*
CO —
Clean Out
M1 —
Monitor Tube
{z ; •*
•`: 0,
TH —
Test Hole
c 49th /
FCO
— Foundation Cleanout
�,j j �j
2CO
—Double Cleanout
MICHAEL E. ANDERSON :
No. CE -4381 ;
PLAN
AS
BUILT
��-
t� �� ROrresl�NP�s��
SCALE
1" = 30'
W
rri
rn
N
J
W
LLI
Ld
LLJ
Ld
Z
LLI0
On -Site Water and/or Wastewater System
Permit
MUNICIPALITY OF ANCHORAGE
Development Services Department
On -Site Water & Wastewater Program
4700 Elmore Road, PO Box 196650
Anchorage, AK 99519-6650
Telephone: (907) 343-7904
Permit Number: OSP151232
Tax Code Number: 02054137000
Work Type: SepticTank Upgrade
Permit Effective Dates: August 11, 2015 to August 10, 2016
Design Engineer: ANDERSON ENGINEERING
Subdivision: RABBIT CREEK VIEW & HEIGHTS
Site Legal Address: RABBIT CREEK VIEW & HEIGHTS BLK 4V LT 4A G:3241
Owner/Address: BOUTET JACQUES M M &
GRYDER-BOUTET DONNA E %BOUTET COMPANY 9043 SNOWY OWL LANE ANCHORAGE AK 995072
Site Mailing Address: 16100 GENEVIEVE ST, Anchorage
This permit is for the construction of:
N Disposal Field Y Septic Tank N Holding Tank N Privy
All construction must be in accordance with:
Lot Size in Sq Ft: 30761
Total Bedrooms: 4
N Private Well N Water Storage
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater
Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80).
3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services
Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either:
A. Open and Close on the same day.
B. Covered, sealed, and heated to prevent freezing.
Received
Issued By
MUNICIPALITY OF ANCHORAGE
Community Development Department Phone: 907-343-7904
Development Services Division Fax: 907-343-7997
On -Site Water & Wastewater Program
ON-SITE SEWER/WELL PERMIT APPLICATION
Parcel I.D. 020-541-37
Property owner(s) Jacques & Donna Boutet Day phone 646-1601
Mailing address 9043 Snowy Owl Lane Anchorage, AK 99507
Site address 16100 Genevieve Street Anchorage, AK 99516
Legal description (Sub'd., Block & Lot) Rabbit Creek View & Heights, Block 4V, Lot 4A
Legal description (Township, Range & Section)
Lot Size 30,761
Sq. Ft.
Number of Bedrooms Threeol y
APPLICATION IS FOR:
APPLICATION IS AN:
TYPE OF DWELLING:
[M all that apply)
Initial ❑
Single Family (SF)
El
(w/wo ADU)
Septic Tank
El
Upgrade 0
Duplex
Duplex (D)
❑
Holding Tank
El
Renewal El
Dwellings
❑
Privy
❑
(SF and/or D)
Private Well
❑
Water Storage
❑
THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR:
Dis tance:
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
(Signature
property owner or authorized agent)
Permit/Rush Fees: AA Waiver Fees:
Date of Payment: '1(20)15f% Date of Payment:
Receipt Number: 6!5q AA 6) Receipt Number:
Permit No. O�ip 1 S �Z�i 2 Waiver No.
piieovi., - k�2S'orP1%�o�.-�:��d u`ev�IIe w eow,��,n�-�ed�l^�vr �l-u ve,rnDv?�,n�
� p p'upV%,� �. �Ui E��ic1 i ��Q .LOr J`e�inlnd
Permit App_9-1-12.doc ` J
ANDERSON ENGINEERING
P.O. BOX 240773
ANCHORAGE, AK 99524
522-7773 522-6779 (FAX)
August 11, 2015
Municipality of Anchorage
Development Services Department
On -Site Water and Wastewater Program
4700 South Bragaw Street
Anchorage, AK 99519-6650
Subject: Lot 4A, Block 44, Rabbit Creek View and Heights Subdivision
Septic System Design and Permit Application
Impacts to Adjacent Properties
Dear Onsite Services Engineer
The septic tank on Lot 4A, Block 4H, Rabbit Creek View and Heights Subdivision has
failed and must be replaced. In addition, the outlet of the tank is completely plugged
and no efflulent can access the absorption bed. We are therefore requesting a permit
be issued for the construction of a new 1,250 gallon steel septic tank to serve the
home. The attached Site Plan and backup documentation identify the location and
configuration of the existing septic system and the location of the new tank. Also
identified on the plans is the existing well on the lot and those on the adjacent
properties. No conflicts existing between the well separation distance the septic system
on this or the adjacent lots. The existing tank on the lot will be properly disposed in
accordance with Municipal Code.
The existing absorption system will remain in place for continued service. The monitor
tubes and cleanouts in the bed are ineffective and improperly located. They will be
replaced with new vents at the correct locations.
The ground surface on the lot slopes at a grade of 7% to the west in the area of the
septic tank. The tank will be constructed near the location of the old tank and in
conformance with Municipal requirements.
If the tank is constructed in accordance with our design the following statements apply
The tank, if constructed as designed, will have no adverse impact on the wells in
the area or those to be constructed in the future.
Lot 4A, Block 414, Rabbit Creek View and Heights
August 11, 2015
Page 2 of 2
2. The tank, if constructed as designed, will have no adverse impact on existing
septic systems in the area or those to be constructed in the future.
3. The tank, if constructed as designed, will have no adverse impact on reserve
space, either surface or subsurface, on any lots located in the area.
4. The tank, if constructed as designed, will have no adverse impact on drainage
patterns in the area. The current drainage pattern will be maintained.
Sincerely,
7 ✓ e -
Michael E. Anderson, P.E.
Attachments
O
O
Ga
W
6
LOT 4A, BLOCK 4HV
LOT 2A RABBIT CREEK V & H
30,761 SF
RVE
VWELL
PROTECTI
RgDI=100'
US
1
1
�
3
N 89'37'15"E 187.70
30.1
/
3
10' UTILITY EASEMENTS
W z
�SV i
Q Y
W
2CO SV 1,250 Gallon
Septic Tank
�.
a.
Ljj
------
,—
/
O
X
r—r –f
CO //
--
O
MT
• I
//
U)
/ FCO
Existing
Absorption
I I
/ TBM _ OF
CONCRE E PL
C1
r 7
W
Bed
ELEV. 100.00 ASSUMED
>
W
•I
MT i
>
CO
J
W
Z
I
W
I
/�
V
I
I
WELL
10'x20' NATURAL
GAS EASEMENT
S 89°41'55"W 187.11'
SCOPE OF WORK LOT 6A
Decommission Existing Septic LEGEND
Tank in Accordance with Municipal S1 — Septic Vent
Code. Place New 1,250 Gallon CO — Clean Out
Septic Tank M1 — Monitor Tube
.p������,�1
OF
and 2 — Post Tank
��� ,
.44
.......
Clean Outs. Tie In Existing TH — Test Hole
. = ��P
Absoorption Bed. Place Clean FCO — Foundation Cleanout
s
Outs and Monitor Tubes in
49th
Absorption Bed.
0'j% J r
SITE PLAN
..............................�.........+..-.-.5..
'�' """AE` E -4381 °" 4
•� f't IVO. CE -4381
f♦1���f!
,•'•.`:
SCALE 1" = 30'
8.11-1 ' -
MUNICIPALITY OF ANCHORAGE
I DEPARTMENT OF HEALTH & ENVIRONMFNTAL PROTECTION
ENVIRONMENTAL ENGINEERING
DIVISION
825 L Street - Anchorage, Alaska 99501
Telephone 264-4720
ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR
WELL INSPECTION
REPORT
NAME
PHONE
❑ NEW
g royj 0w_
3,+5 1454
3e IPGRADE
MAILING ADDRESS
16 1 oa Genevi"e_
LEGAL DESCRIPTION
RAb�t'F CfeeK View Loo 4 aloc.kL- eke
T1(NIZ
LOCATIO
NO. OF BEDROOMS
�y
4
t° !A�' l 1 _4e i
Well
Absorption area
Dwelling
PERMIT NO.
U
DISTANCE TO:
1 v 8
20
6S
9$ 0L 9506S
yi
aManufacturer
UJ
1)nchora
Material
SF��
No. of compartments
Liq. capacity in gallons
Inside length
Width
Liquid depth
2—,5-C)
IF HOMEMADE:
0
DISTANCE TO:
Well
Dwelling
PERMIT NO.
=Oz
Z F
Manufacturer
Material
Liquid capacity in gallons
D
DISTANCE TO:
Well
Foundation
�$
Nearest lot line
4 8
PERMgNO.
S'616 5
LU
��j'j,,
W LL U
w
'No. of lines
6
Len th of each I'ne
Total length of lines
Trench width
'
Distance between lines
� ?
,;t, t4. 4
200
/ inches
4-6
zi H
Top of tile to finish grade
Material beneath tile
Total effective absorption area
p
Q
4 inches
� LL
Length
Width
Depth
PERMIT NO.
LU
C9
Q F
Type of crib
Crib diameter
Crib depth
Total effective absorption
area
as
w
WWell
W
Building foundation
Nearest lot line
DISTANCE TO:
J
Class
Depth
Driller
Distance to lot line
PERMIT NO.
J
W
Building foundation
Sewer line
Septic tank
Absorption area(s)
DISTANCE TO:
OTHER
0W Sl 1
ierh
PIPE MATERIALS
3034 (81e
(ceYw
t`t
e)
a
O
SOI L TEST RATING
3 g C1'/b
7777 r,
6
INSTALLER
Df?- Hr fncUry �il(a�sa`I�"n �'% �S3'� O"•�
2
.t.
r
REMARKS
(nS eci-ecl b L�wrc wroR S•C8J'O Z
li �t5
i
Them
Sol C
S; - km W&S tarp
/.�'
C I l e lk _rjr br (rt,,S @ 1•r� rUc,C t J,c.S '`-r� r,,;..rrlts�i
wel
W -,5 s",,A to,.
t
M
e
IV
APPROVED DATE LEGAL
- 11: /D ��
7!' ea %G:. /C'f - [ A4.n.
1..t in dJ r ._ 2,
fS_
' ' ~
. �
` �
' ��������������� �� ������������
`
` DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION
825 L STREET, ANCHORAGE, AK 99501
264-4720
`
` ����
PERMIT NO: 850265
DATE ISSUED: 06/06/85
APPLICANT: BYRON WILSON
ADDRESS: 16100 GENE0IEVE '
ANCHORAGE. AK 99516
CONTACT PHONE: 345-1454
LEGAL DESCRIP:SUBDIVISION. RABBIT GREEK VIEWLOT. 4 ' BLOCK: 4 �
SECTION: I.8 TOWNSHIP: 11N RANGE: 3W
LOT SIZE: (SQ.FT. OR ACRES>
MAX BEDROOMS Z.[/
Listed below are t.h ti available t i1ri designing you septic
system. Choose the
� �
-_
DEPTH TO PIPE BOTTOM
8RAVEL DEPTH (FT.) .5 1.5
TOTAL DEPTH (FT.)
GRAVEL WIDTH (FT.)
GRAVEL LENGTH (FT.) _. 0 ��� 86.0
**
- �_�
GRAVEL V8LUME (CU.Y 31.2 /� ~ 31"9
TANK SIZE (GALS)1,250.0 1,250.0 **
SOIL RATING (SQ.FT. /BR) 138 138
** DEPTH TO PIPE BOTTOM < 3.5 FT" REQUIRES INSULATION
**
DE' TOYPIPE BOTTOM < 4"0 FT" MAY REQUIRE A LIFT STATION
**GRAVEL LENE"TH > 75 FT, REQUIRES MULTIPLE RUNS (NOT EXCEEDING
** TANK MUST HAVE AT LEA13'T TWO COMPARTMENTS
..... ..... ������.... �.....
��������������������
75 FT. EACH)
I certi�y that: ^
1" I am f*amiliJir with the requirements f'or on-site sewers and wel1s as set
forth by the Municipality o[ Anchorage (MDA) and the State of' Alaska.
2, I will install the system in accordance with all MOA codes and regulations,
and in compliance with the design criteria of this permit.
3. I will adhere to all MOA and State o[ Alaska requirements for the set back
distances f'rom any existing well, wastewater disposal system or public
sewerage system on this or any adjacent or nearby lot"
4, I understand that this permit is valid for a maximum of* 4 bedrooms and
any enlargement will require an additional permit. ,
IF A LIFT STATION IS INSTALLED IN ANAREA COVERED BY MOA BUILDING CODES,
THEN (1) AN ELECTR IC4L PERMIT AND INSPECTION MUST BE OBTAINED; (2) AS-BUILTS
WILL NOT BE APPROVED WITHOUT AN ELECTRIGAL INSPECTION REPORT; AND (3> THE
ELECTRICAL WORK MUST BE DONE BY A LICENSED ELECTRITCIAN"
SIGNED
APPLICANT: BYRON WILSON
y0
T�A1|Fn A�Y .�,. .^, _ . /V°-'_~
DATE:
DATF:
�
~ /m />�,\
PERMIT NO:
DATE ISSUED:
APPLICANIT:
ADDRESSW
CONTACTP: IONE:
KD Ts!~-- W 1:~V K M M Up EHJTT M EE HAT 1-1 1~�
850265
06/06/85
BYRON WILSON
16100 GENEVIEVE
ANCHORAGE, AK 99516
345-1454
LEGAL DESCRIP: SUBDIVISION:
RABBIT CREEK
VIEW
LOT: 41 L/
SECTION: 18
TOWNSXIP:
11N
RANGE: ��y
LOT SIZE: 43000 (SQ.FT.
OR ACRES)
138 138
' \
MAX BEDROOMS: 3
0[/�^^
@-/
MAX BEDROOM�
BLOCK: 4
/-
/
V
!HNK
SIZE <WHL3|
UT
",0 ** ,�u;.�
**
L.
RATING (SQ,FT./BR)
/
\l
138 138
\J
\�/'
**
DEPTH TO PIPE
BOTT < 3`5
FT.
REQUIRES INSULATION
**
DEPTH TO PIPE
i3 crp i OM < 4.0
FT"
MAY REQUIRE A LIFT
STATIOM ,
**
TANK MUST HAVE
AT LEAST
TWO
COMPARTMENTS
�
I certi{y
that: /
/
i ha r,
with the requirements
�
for on-site
sewers and wells as s�t
Vort 11 13 he Municipality
of
Anchorage (MOA> and
the StatEW oV Alaska.
2,
I 04 j. 1 l
the system
in
accordance with all
MOA codes and regulations;
and i compliance
with the
design
Criteria us this
permit.
3"
I wiI3 adhere
toall MOA
and
State o� Alaska requ0rement1;
[or Lhe set back
dista:ces from
any existing
well, wastewater disposal
system or public
sewerage syste�
on this
or any
adjacent or nearby
lot.
4.
I understand that
this permit
is valid For a maximum
o� 3 bedrooms and
any enlargement
will require
an additional
permit.
M -W Drilling, Inc.
♦ P.O. Box 110378 ♦ Anchorc le, A K 99511
•907-345-4000 ♦ 907-3,15-3287 Fax*
Job No.: 02-137 Project No.: N/A Permit No. SWO20189
Groundwater Well As -Built & Lot;
♦ Well Owner. Boutet, Donna _ ♦ Use of Well: Domestic
♦ Legal Description. Rabbit Creek View, Block 4, Lot 4
16100 Genevere- Anchorage, Alaska
Constructioi t
♦Hole Depth: 205' ♦Casing Size. 6" *Cased To: 37' ♦Materlal: A 53 Steel
♦Drill Method: Air Rotary
Perf.
♦ Well Completion- Open end X Screen _ Perforated ! Method:
♦Screen/Perforation description: None
♦Grout Notes: 10" Surface casing installed & pulled while grouting annulus with bentonite. NfR
♦ Notes: -4011C TO S042,
♦ Well Development: Method. Air surge Note e.
*Static water level (SWL) 25' (above) (below) top c (casing (TOC).
♦ Well yield test at 2.5 gallons per minute (GPA Iga (Ions per hour (GPH) for 1 hours
with 100% of drawdown (DD) from static level (SWL).
*Method. Airlift
♦Date of completion: 25 June 2002 0Pump Install: 26 June 2002
Well Log
Depth in feet from
top of casing. Details of formations nenetrai ed, size of materlal; color and hardness.
0 TO 2 Casing stickup
2 TO 5 Topsoil
5 TO 17 Gravel: sandy, coarse
17 TO 20 Fractured bedrock
20 TO 205 Bedrock: gray/black, siltstone a-gillite, small water leaps in sporadic
TO fractures.
TO
TO
TO
TO
TO
TO
TOj
TO
TO
TO NwwA Certified ContrPetor
TO Certificate No's. 814 &'072
I
r
w � S
M- W Drilling, Inc.
MEMO
01 July 2002
To: Whom It May Concern
From: Wayne Westberg, President
Re: Rabbit Creek View Subdivision, Lot 4, Block 4
Subject: Well Decommissioning
This is to verify that the old well (74' total depth, ? foot of casing) was decommissioned in
the following manner:
1) Pump pulled, waterline disconnected.
2) Back-filled with coarse bentonite chips to minus 10 feet.
3) Casing cut off at minus 10 feet (ie. Below old pitless unit) and a4"' steel plate
welded on top.
NWWA Certified Contractor
Certificate No's. 814 & 973
uP.O. Box 110378u Anchorage, AK 995111)
uPhone:907-345-4000uFax:907-345-3287u
0 'r are our business!!i
George P. lhaereh,
Mayor
May 12, 2003
Jacques Boutet
16100 Genevieve St.
Anchorage AK 99516
Mtmicip":ty oiAnchorage
Building Safety Division
Subject: On -Site Water and/or Wastewater Permit.
Permit Number: SW020189
Legal Description: Rabbit Creek View Block 4 Lot 4
Dear Jacques Boutet:
Anchorage
2002
An On -Site Water/Wastewater Permit, number SW020189, issued by this office for a single-family
system, will expire on June 24, 2003. This permit was valid for365 calendar days.
If this was'a well permit and the well has been drilled, a well log must be sent to this office for
documentation of the installation and to close the permit.
If this permit was for a wastewater disposal system, an original as -built inspection report must be sent to
this office for review, approval and documentation. This as -built inspection report must be signed by
the licensed Professional Engineer who inspected the installation of the system. As -built inspection `
reports are required to be submitted within 30 days of the completion of the system.
If no system was installed under this permit, and you are still planning to install a well or wastewater
disposal system, anew permit must be obtained from this office.' A newpermit for a'second year may
be issued for a fee of $100.00 if the renewal application is received on or before the expiration date of
the original permit.
When applying for anew permit, the fees are: $400.00 for a wastewater permit and $150.00 fora well
permit.
If you have any questions, please call this office at 343-7904.
Sincer,
J s Cross, P.E.
Manager
On -Site Water and Wastewater Program
Enc: Copy of permit
P.O. Box 196650 • Anchorage, Alaska 99519-6650 • Telephone: (907) 343-8301 • rax: (907) 343-8200
4700 South Bragaiv Street • Anchorage, Alaska 99507
littp://ihxiv.ci.anchorage.,alc.us
h
' MUNICIPALITY OF ANCHORAGE
Development Services Department
On -Site Water & Wastewater Program
4700 South Bragaw Street
P.O. Box 196650, Anchorage, AK 99519-6650
(907) 343-7904
ONSITE WATER SUPPLY PERMIT
Initial
Date Issued: Jun 24, 2002
Expiration Date: Jun 24, 2003
Permit Number: SW020189
Parcel ID:
020-032-21
Legal Description:
RABBIT CREEK VIEW BLK 4 LT 4
Design Engineer:
0014 Anderson Engineering
Site Address:
016100 GENEVIEVE ST
Owner Name:
Jacques Boutet
Lot Size:
31445 SQ. FT.
Owner Address:
16100 GENEVIEVE STREET
Total Bedrooms:
4 Permit Bedrooms: 4
ANCHORAGE, AK 99516-5237
This permit is for the construction of:
C Disposal Field [] Septic Tank Holding Tank E Privy Private Well ❑ Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ).
3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling
(907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
must be either: A. Open and closed on the same day.
B. Covered, sealed, and heated to prevent freezing.
Received By:
Date:
Issued By: r �,. �—� ' Date: 6 z
Municipality of Anchorage
• '� Development Services Department"GEB`
Building Safety Division ax
On -Site Water and Wastewater Program IS
'-
4700 South Bragaw St. 5 "
P.O. Box 196650 Anchorage, AK 99519-6650
www.ci.anchorage.ak.us
(907)343-7904
ON-SITE SEWER/WELL PERMIT APPLICATION
FOR A SINGLE FAMILY DWELLING
Parcel I.D. _ r'y2o —O6a — '-) 1 Permit Number SW
Property owner(s) Jacques Boutet and Donna Gryder-Boutet Day phone 345.6314
Mailing address (1) 9043 Snowy Owl Circle Anchorage AK 99507
Mailing address (2) Zip Code
Legal description (Lot, Block & Sub'd.) Lot 4, Block 4 Rabbit Creek View Subdivision
Legal description (Section, Township & Range)
Lot Size__j,1 LIL/ S Acres q.Ft:
THIS APPLICATION IS FOR:
Sewer Only ❑
Sewer and Well ❑
Sewer Upgrade ❑
THIS PROPERTY CONTAINS:
Hot Tub
Swimming Pool
Therapy Pool
Number of Bedrooms Four (4)
Well Only
Water Storage
Jacuzzi ❑
Water Softening Unit ❑
I certify that the above information is correct. I further certify that this application is being made for a
Single Family Dwelling and is in accordance with applicable Municipal Codes.
(Signature of property owner or authorized agent)
Permit Fees: i ` �� Waiver Fees:
Date of Payment: G a b
Receipt Number:
(Rev. 12/00)
Date of Payment:
Receipt Number:
June 18, 2002
Municipality of Anchorage
Development Services Department
On -Site Water and Wastewater Program
4700 South Bragaw Street
Anchorage, AK 99519-6650
Subject: Lot 4, Block 4, Rabbit Creek View Subdivision
Well Placement and Permit Application
Impacts to Adjacent Properties
Dear Onsite Services Engineer
The owners of Lot 4, Block 4, Rabbit Creek View Subdivision intends to place a new
well on the property in an attempt to increase the water production available to the four
bedroom home on the lot. The location of the well and the 100' protective radius are
shown on the attached site plan. No conflicts exist between the location of the new well
and septic systems on adjacent properties. We hereby apply for a permit to construct
the new well.
Please let me know if you have additional questions.
�Sincerely,
Michael E. Anderson, P.E.
Attachments
PROPOSED BUILDING CORNER EE
T
O
Z
5-89`42'
W_-_^ ISO. 00
10'1,171117-Y
<J EASEN/EA/T
Ne �
i RUN .�' a, rWel
J �
NOTE: Abandon Existing Well In Accor ance
_ With AD Requirements.
4Z'WT- _ f 90.00
NOTE: No Conflicts With Septic
Systems on Adjacent Lots.
... UNDER NO CIRCUMSTANCES SHOULD AN AS—WILT BE USM FOR. .
THE SURWY.OR TAKES RESPCNSIBUrr FOR 7HE RHITIAI. TRANSACRCN OR
„vec.............._ __.. .ONLY AND ASSII _ rn
LOT SURVEY SURVEY ramE
AS—MMT ... NO CORNERS SET
RECIERWICATON AS—BUILT . - - NO CORNERS SET
Lar SURVEY
A5 -OMT PLOT PLAN
REcaTnr•TrwAa, AS—BIACT
dWy� � flat T lot
dy*d the
ram and descried hereon
and that L have found or
es-LabUshed all of the lot
Comers. AS sham w Vw Plm
WA is Vw bestww of Ry Imo.l.dpr
be- mowed met
Eosenents of record, other
tlrs +lase slime m the eerna.d
Plat. ore not shown hereon
T,= =70-4 Wens
AND
�T
'azzlw m a wa
pa. ..
L�
ASPHALT
CONCRETE
ONLY THOSE IMPROVEMENTS ABOVE GROUND AND' NSIBLE WILL BE
SHOWN. FENCES WELLS SEPTIC CLEANOUT,' SIDEWALKS DRIVEWAYS.
ETC:, ARE SHOWN IN THEIR APPROMMATE LOCATION. ONLY.'
EN
MAY PREVENT SOME IMPROVEMTS SNOW
FROM BF]NG
SEEN AND LOCATED
Prepared by
Robert E. Johns, Jr. & Assoc.
Professional Land Surveyors
40' REC. LOT S.F.
1"
3241 92-056
LOT 4, BLOCK, 4, RABBIT CREEK VIEW.SUBD.
CO,b
Q
CA
-
.30g 23�
I
;
2 DANT
o
l i
ZG3
2 STa.v.v
FR/4*ff
:YD u3G
WfOtlYU6/-/T
! w
�
:In
i RUN .�' a, rWel
J �
NOTE: Abandon Existing Well In Accor ance
_ With AD Requirements.
4Z'WT- _ f 90.00
NOTE: No Conflicts With Septic
Systems on Adjacent Lots.
... UNDER NO CIRCUMSTANCES SHOULD AN AS—WILT BE USM FOR. .
THE SURWY.OR TAKES RESPCNSIBUrr FOR 7HE RHITIAI. TRANSACRCN OR
„vec.............._ __.. .ONLY AND ASSII _ rn
LOT SURVEY SURVEY ramE
AS—MMT ... NO CORNERS SET
RECIERWICATON AS—BUILT . - - NO CORNERS SET
Lar SURVEY
A5 -OMT PLOT PLAN
REcaTnr•TrwAa, AS—BIACT
dWy� � flat T lot
dy*d the
ram and descried hereon
and that L have found or
es-LabUshed all of the lot
Comers. AS sham w Vw Plm
WA is Vw bestww of Ry Imo.l.dpr
be- mowed met
Eosenents of record, other
tlrs +lase slime m the eerna.d
Plat. ore not shown hereon
T,= =70-4 Wens
AND
�T
'azzlw m a wa
pa. ..
L�
ASPHALT
CONCRETE
ONLY THOSE IMPROVEMENTS ABOVE GROUND AND' NSIBLE WILL BE
SHOWN. FENCES WELLS SEPTIC CLEANOUT,' SIDEWALKS DRIVEWAYS.
ETC:, ARE SHOWN IN THEIR APPROMMATE LOCATION. ONLY.'
EN
MAY PREVENT SOME IMPROVEMTS SNOW
FROM BF]NG
SEEN AND LOCATED
Prepared by
Robert E. Johns, Jr. & Assoc.
Professional Land Surveyors
40' REC. LOT S.F.
1"
3241 92-056
LOT 4, BLOCK, 4, RABBIT CREEK VIEW.SUBD.
ueveioprT
sn
e.
e4/o
reef..
eP6e
i
5.A MY'
N
S"HE
T
rr nt well on the lot. ,
D e: 6/20/0
y information and m -sub ri# your request.
, DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION
825 L STREET, ANCHORA8Ev AK 99501
264~4720
ERMIT NO: 850265 ENGINEERED DESIGN
ATE ISSUED:06/06/85
CANT BYRON WILSON
DDRESS: ' 16100 GENEVIEVE
ANCHORAGE� Al-::' 99516
ONTACT PHONE: 345-1454 *
EGAL DESCRIP: SUBDIVISION: RABBIT CREEK VIEW
'4ECTION: 18 TOWNSHIP:11N
OT �IZE: ^ 43^00 (SQ"FT" OR ACRES)
LOT: A.
RANGE: ZW
BLOCK: 4
certify that:
1. I am familiar with therequirements {or onsite sewers and wells as set
(orth by the Municipality o[ Anchorage (MOA) and the Staten of Alaska"
2. I will install the system in accordancewith all MOA codes,and regulations,
and in compliance with the design criteria of this permit.
3. I will adhere to all MOA and State Alaska requirements for the set back
distances From any existing well, wastewater, disposal system or public '
sewerage system on this or any adjacent or nearby lot.
F A LIFT STATION IS INSTALLED IN AN AREA COVERED BY MOA BUILDING CODES,
HEN (1) AN ELECTRICAL PERMIT AND INSPECTIO MUST BE OBTAINED(2) AS�BUILTS
ILL NOT BE APPROVED WITHOUT AN ELECTRICAL INSPECTION REPORT; AND (3> THE
LECTRICAL WORK MUST BE DONE BY A LICENSED ELECTRICIAN.
lGNED
DATE:
~~~~^..... .... _.... .... ..... .... ~~����~�_�_��_~��__���~�_ ......
PPLICANT: BYRON WILSON
SSUED BY DATE:
F;��&m_
�_«� ��
���������... ........
�
n
❑ SOILS LOG
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION ' ERCOLATION
TEST
825 L. Street, Anchorage, Alaska 99501 264-4720
SOILS LOG — PERCOLATION TEST
PERFORMED FOR: al��'14�. !! A-jA/� DATE PERFORMED: V —
LEGAL DESCRIPTION:t,,.,+�_ `�iJ� � 1cTil�� 1"C 2° ll �1P- _! �16 :/ , e -3w Se -j
1 SLOPE SITE PLAN
3 C�—
6-
7
8
10-
11
12 �
13 c14L�
14-
15-
16-
17-
18-
19-
20
4151617181920
COMMENTS
WAS GROUND WATER S
ENCOUNTERED?Vp--) � L
O
P
IF YES, AT WHAT E
DEPTH?
1 `1 In N., k
Reading
Date
Gross
im�.e.�/
Net
Time
Depth to
Net
Drop
�il_
pT,
�f 9^��^' �
j 0
ff'(/
''Water
Y
I
r
r1�
ice; c��
'"
+'!
� _
�
r��
—�
j
�
4
y
N,zo Ll
�{? arra S?w v.ii� .�r--
PERCOLATION RATE S`A� (minus inch)
TEST RUN BETWEEN - AL FT AND FT
a4- <1 r r2
/y PERFORMED BY:ICt>i?\ CERTIFIED BY: , v DA
A !7_
ova
ALASKA ENVIROtMENTAL SHEET NO. OF 'Z -
CONTROL 1 19 to -1 -
SERVI( !� INC. CALCULATED BY DATE
1200 West 33rd Avenue, Suite B
ANCHORAGE, ALASKA 99503 CHECKED BY DATE
(907) 561-5040
2041 IN. 13 W' Mm 01471.
JVO
ALASKA ENVIRONMENTAL SHEET No. 2- of
CONTROL SERVICE )INC.
1200 West 33rd Avenue, Suite B CALCULATED BY 1 DATE
ANCHORAGE, ALASKA 99503 CHECKED Sr DATE
(907) 561.5040
SCALE 1y7 S
I136 n'/4
PMM 2"1®In, Groton, Mm rAn
.M -W DRILLING INC.
P.O. BOX 110378
ANCHORAGE, ALASKA 99511
PHONE 349-8535
NAME
ADDRE55
CITY
2 Zs -/.9
LEGAL DESCRIPTION/, 4/ �¢� /�ar�(i�•
LEGAL OWNERS
BANK OR LENDING INSTITUTIONS CURRENTLY HOLDING DEED OF TRUST
4s-- /¢S4-
HOMEPHONE WORKPHONE
Fnl
INVOICE N0- 2748
DATE A/?��
UNIT
CITY. MATERIALS PRICE AMOUNT
/ Ob
XDAT S r /
l/JL���
/240 S L�-l�8 vr9'!o - LUa/ar. E✓ 3 D - T a
/z4s
/3
/4-v
All charges shall be paid in full within ten
WORKMAN
LI Fi
DATE
IN
OUT
Jv;oreOTAL MATERIALS
HOUR
Z
RATE
S G
g
VyE
/
MATERIALS (FROM ABOVE)
GPM
DRAWDOWN
AA
/
S
PUMP MAKE
HP
S OTTfN `
�af/ rdSP HAJ7 00 AV PRATE
f�
SERIAL NUMBER
MODEL
SCREEN LENGTH SLOT SIZE LINER//SCREEN
DESCRIPTION OF WORK
CUSTOMER SIGNATURE
XDAT S r /
l/JL���
/240 S L�-l�8 vr9'!o - LUa/ar. E✓ 3 D - T a
/z4s
/3
/4-v
All charges shall be paid in full within ten
WORKMAN
LI Fi
DATE
IN
OUT
LABOR
HOUR
Z
RATE
S G
g
/
MATERIALS (FROM ABOVE)
days unless other arrangements are made
prior to drilling. The customer shall pay in-,C'd
terest at the rate of 1!12 % per month on any
amount not paid within ten days. Failure to
AA
/
S
C�"�j
OTHER CHARGES
pad may result in a lien against the property.
/'r`a�UNV
0
CUSTOMER SIGNATURE
PAY THIS AMOUNT —►
ALASKA NUIROUBTAL COnTROL HHUIUS,
6ngineerinq & 6nuironmental Studies
SPECIFICATIONS FOR BED WASTEWATER TREATMENT SYSTEM —
LOT 4 BLOCK 4 RABBIT CREEK VIEW
1.0 GENERAL
1.1 THE DRAWINGS, SHEETS 1 THRU 2, SHALL BE PART OF THIS
SPECIFICATION.
1.2 ALL MATERIALS AND WORKMANSHIP SHALL MEET THE
REQUIREMENTS OF THE MUNICIPALITY OF ANCHORAGE,
DEPARTMENT OF HEALTH & HUMAN SERVICES (DHHS), THE
CONDITIONS OF THE PERMIT, AND ALL APPLICABLE
RULES AND REGULATIONS CURRENTLY IN EFFECT.
I[LICIPAIITY OF ANCHORAGE'
f NVIR001gNTAlEPROTECTIpN
i995,
RECEIVED
1.3 ALL EXCAVATIONS AND DEPTHS ARE ADVISORY, AND ARE TO BE
VERIFIED OR MODIFIED IN THE FIELD BY A DHHS APPROVED
INSPECTOR.
1.4 IT IS THE RESPONSIBILITY OF THE INSTALLER TO ADHERE
TO APPROVED DESIGNS FOR INSTALLATION, TO MAINTAIN THE
SPECIFIED SEPARATION DISTANCES, AND TO HAVE THE
APPROPRIATE INSPECTIONS.
1.5 IF THE INSTALLATION IS NOT INSPECTED BY AN AECS
ENGINEER, AECS WILL NOT BE RESPONSIBLE FOR THE
DESIGN. AN ENGINEER AT AECS SHOULD BE CONSULTED
PRIOR TO CONSTRUCTION, TO DETERMINE THE NUMBER OF
INSPECTIONS THAT WILL BE REQUIRED AND TO EXPLAIN
WHAT THESE INSPECTIONS WILL INVOLVE.
2.0 SEPTIC SYSTEM
2.1 THE SEPTIC TANK SHALL BE A UPC—APPROVED TWO—COMPARTMENT
TANK, CONSTRUCTED OF 12—GAUGE STEEL WITH BITUMASTIC
COATING, SET LEVEL ON UNDISTURBED SOIL, AND INSULATED
WITH AN OVERLYING LAYER OF 2 INCH BURIAL TYPE
POLYSTYRENE.
2.2 THE SEPTIC TANK SHALL BE A MINIMUM OF 5 FEET FROM THE
HOUSE FOUNDATION, AND A MINIMUM OF 5 FEET FROM THE
ABSORPTION AREA.
2.3 THE SEPTIC TANK AND BED'SHALL'BE A MINIMUM OF 100 FT.
FROM ANY PRIVATE WELL OR BODY OF WATER, 150 FEET FROM
CLASS C WELLS, AND 200 FEET FROM CLASS A OR B WELLS,
UNLESS OTHERWISE SPECIFIED. LESS THAN THE REQUIRED
SEPARATION DISTANCE MUST HAVE PRIOR,APPROVAL OR WAIVER
BY ALASKA DEPARTMENT OF ENVIRONMENTAL CONSERVATION
(ADEC).
»nn I11rst 33rd Auenue Suite B • Anchorage. Alaska 99503+(907) 561-5040
2.4 PIPING SHALL BE FITTED WITH A MECHANICAL WATERTIGHT
CALDER COUPLING ON THE OUTLET AND INLET OF THE
SEPTIC TANK. PIPING SHALL BE 4 -INCH SOLID PVC ASTM
D3034 OR CAST IRON, SLOPED A MINIMUM OF 1/4 INCH PER
FOOT WITH A MINIMUM OF 4 FEET OF COVER.
2.5 CLEANOUTS SHALL BE INSTALLED AS DESIGNATED AND CAPPED
WITH AIR -TIGHT RAIN CAPS (JIM CAPS OR EQUIVALENT), AND
EXTEND A MINIMUM OF 2 FEET ABOVE GROUND LEVEL.
3.0 SEEPAGE BED
3.1 THE GRAVEL FOR THE BED SHALL BE 0.5 TO 2.5 INCH,
SCREENED ROCK WITH LESS THAN 3% PASSING #200 SIEVE
RESIDUAL. ALL SUBSTITUTES MUST HAVE PRIOR DHEP
APPROVAL.
3.2 THE BOTTOM OF THE EXCAVATION SHALL BE LEVEL AND RAKED
WITH THE BACKHOE BLADE TO INSURE THAT THE BOTTOM HAS NOT
BEEN COMPACTED DURING EXCAVATION.
3.3 THE DISTRIBUTION PIPE SHALL BE 4 -INCH RIGID PVC WITH
A MINIMUM CRUSH STRENGTH OF 1500 LBS. ALL PIPES SHALL
BE LAID LEVEL, AND SPACED ACCORDING TO THE DRAWINGS.
3.4 MONITOR STANDPIPES SHALL BE PLACED AS SHOWN IN THE
DRAWINGS. THEY SHALL BE RIGID PVC ASTM D-3034, OR
OR 4 INCH DIAMETER CAST IRON. THE SECTION SHOWN WITH
HOLES MAY BE EITHER DRILLED 0.5 INCH HOLES ON THE 6 INCH
CENTERS ON OPPOSITE SIDES OF THE PIPE, OR A SECTION OF
REGULAR PERFORATED SEWER PIPE MAY BE CLAMPED TO THE
SOLID SECTION WITH A NO -HUB COUPLING OR SOLVENT JOINT.
A RUBBER RAINCAP (JIM CAP OR EQUIVALENT) SHALL BE PLACED
OVER THE TOP OF THE PIPE.
3.5 IF THE FINAL GRADE OVER THE BED IS LESS THAN 4 FEET
ABOVE THE GRAVEL, INSULATION IS REQUIRED, USING DOW
EXTRUDED BLUE STYROFOAM BOARD. THERE SHALL BE 1 INCH OF
INSULATION FOR EVERY FOOT OF SOIL LESS THAN THE REQUIRED
4 FEET OF COVER, BUT THERE MUST BE AT LEAST 18 INCHES OF
SOIL EVEN THOUGH INSULATION IS USED. THE SOLID PIPE
EXTENDING FROM THE SEPTIC TANK TO THE DRAINFIELD SHALL
ALSO HAVE 4 FEET OF COVER OR AN EQUIVALENT LAYER OF
INSULATION COMBINED WITH SOIL TO PREVENT FREEZING OF
THE LINE.
3.6 IF INSULATION IS NOT NECESSARY, THEN THE GRAVEL MUST BE
COVERED WITH A LAYER OF A NONWOVEN FABRIC (SUCH AS
MIRAFAI, FIBRETEX 200 GRADE, POLY -FILTER X, OR
EQUIVALENT).
3.7 THE TOP AND SIDES OF THE BEDS SHALL BE PLANTED WITH A
WHITE CLOVER AND RED<FESCUE MIX OR BLUE GRASS.
4.0 INSPECTIONS
4.1 THIS BED WILL REQUIRE THREE INSPECTIONS. THE FIRST
INSPECTION WILL BE OF THE OPEN EXCAVATION, TO ASSURE
THAT THE SYSTEM IS INSTALLED IN PROPER STRATA AND
DEPTH.
4.2 THE SECOND INSPECTION WILL BE OF THE NFS SAND.
4.3 THE THIRD INSPECTION WILL BE AFTER PLACEMENT OF THE
GRAVEL, MONITOR STANDPIPES) AND DISTRIBUTION PIPE TO
VERIFY PROPER INSTALLATION AND MATERIALS PRIOR TO
BACKFILL.
ro
w
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION
DIVISION OF ENVIRONMENTAL HEALTH
CERTIFICATE OF INSPECTION FOR HEALTH AUTHORITY APPROVAL
OF ON-SITE SEWER AND WATER FACILITY
264-4720
Application Date' 1 15:5 —
1. GENERAL INFORMATION
(a) Legal Description (include lot, block, subdivision, s tion, township, range
13tOr3�. y ®� 1�b i i- �',P �e O ico
- -r I N R3LAD
Location (address or directions) io
Genay I g- VE
qS
(b) Applicant Name lA.!•®��� Telephone: Home Business 3-' ySLA
Applicant Address
(c) Applicant is (check one): Lending Institution 0 ; Owner/builder CK; Buyer ❑ ; Other ❑ (explain);
(d) Lenaing Institution ' WE SA 1&0� • �Q ETelephone
Address —
(e) Real Estate CpmOar , and Agent
Address'
Telephone-' "
(f) Mail e HAA to the ollowing address:
2. TYPE OF RESIDENCE
Single-FamilylA Multi -Family ® Other
Number of Bedrooms
3. WATER SUPPLY
Individual Well Community ❑ Public
Note: If community well system, must have written confirmation from the State Department of Environmental Conservation
attesting to the legality and status.
4. SEWAGE DISPOSAL
Onsite)f Public ❑ Community ❑ Holding Tank O
Note: If community well system, must have written confirmation from the State Department of Environmental Conservation
attesting to the legality and status.
-Pace 1 of 2 72-025 (11/84)
5. ENGINEERING FIRM PROVIDING INSPECTIONS, TESTS, FILE SEARCH, DATA AND INFORMATION
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of Irwi% 446Ws
Authority Approval shows that the on-site water supply and/or wastewater disposal system is safe, functional ana
for the number of bedrooms and type of structure indicated herein. I further verify that based on the information ots mfu,rt
from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply arw,rr
wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on
the date of this inspection.
Name of Firm ryS
Address ` G—
r ' '�i4itU7,
�.r< .. ■
ti, I' t / 1
• ?,
it
l
29
6. DHEP APPROVAL {
. , ... /pate l�i�°� 1 �'1�
Approved for �� bedrooms by d,,
f
Approved Disapproved Conditional
Terms of Conditional Approval
CAUTION
The Muncipality of Anchorage Department of Health and Environmental Protection (DHEP) issues Health Authority
Approval certificates based solely upon the representations given in paragraph 5 above by an independent professional
engineer registered in the State of Alaska. The DHEP does this as a courtesy to purchasers of homes and their lending
institutions in order to satisfy certain federal and state requirements. Employees of DHEP do not conduct inspections or
analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the
professional engineer's work.
Pana 9 of 9
X1 MUNICIPALITY OF ANCHORAGE
MUNICIPALITY OF ANCHORAGE. (MOA) DEPT. OF HEALTH &
ENVIRONMENTAL PROTECTION
HEALTH AUTHORITY APPROVAL (HAA) y
CHECKLIST - FEBRUARY 1984 AUG 0 8G7'
264-4720
Legal Description: _4071V
A. WELL DATA
Well Classification
P, If A, B, C, D.E.C. Approved (Y/N) 'VZ9–
Well Log Present (Y)I Date Completed Yield
Total Depth? Cased to 22 s Depth of Grouting
Static Water Level :30/
30/ Pump Set At
Casing Height Above Ground Sanitary Seal on Casing)
Electrical Wiring in Conduit ) Depression Around Wellhead (Y6
Separation Distances from Well: 1W /
To Septic/Holding Tank on Lot `, _'4
; On Adjoining Lots
To Nearest Edge of Absorption Field on Lot $S7 ; On Adjoining Lots
To Nearest Public Sewer Line
Cleanout/Manhole
Water Sample Collected by _
Water Sample Test Results _
Comments
To Nearest Public Sewer
To Nearest Sewer Service Line on Lot 6
Date
B. SEPTIC/HOLDING TANK DATA 0/j/ y
Date Installed
Standpipes (Y/N)
Depression over Tank (Y/N)
Size
Air -tight Caps (Y/N)
Pumping/Maintenance Contract on File (Y/N)
Holding Tank High -Water Alarm (Y/N)
Separation Distances from Septic/Holding Tank:
To Water -Supply Well —
To Property Line
To Water Main/Service Line
Course
Comments
Page 1 of 2
No. of Compartments
Foundation Cleanout (Y/N)
Date Last Pumped
;for
Temporary Holding Tank Permit (Y/N)
To Building Foundation
To Disposal Field
To Stream, Pond, Lake, or Major Drainage
C. ABSORPTION FIELD DATA
Soils Rating in Absorption Strata �aType of System Design _/2
Date Installed u Ztso_& r Length of Field 4L"X ^- --
Width of Field LA�XDepth of Field�1
Gravel Bed Thickness
Square Feet of Absorption Area bc_7�+0_- Standpipes Present (Y&}I
Depression over Field (Y&
—
Results of Last Adequacy Test
AN 114
Date of Last Adequacy Test A./0 A -,6 -
Separation Distance from Absorption Field:
To Water -Supply Well $3 / To Property Line
To Building Foundation - To Existing or Abandoned System on
Lot __ &444`. ; On Adjoining Lots 7`30 ' '�!
To Water Main/Service Line�'2 To Cutbank (if present)
To Stream/Pond/Lake/or Major Drainage Course fi /DO
To Driveway, Parking Area, or Vehicle Storage Area
Comments _�� SGo�i'c nA�— ®zr/x�2o �.�r-411* 947 �++JK /1u/ /
G!t /tEiJ ..` j��yrt ho S><a�ncYpiuC htFaetvt2 r7 own Cr/LF�c./ G�dtrar�a�
LIFT STATION
Date Installed
Size in Gallons
"Pump On" Level at
High Water Alarm Level at
Tested for
Electrical Codes tY/DLY�
Dimensions
Manhole/
** Check Permitted Bedroom Rating Against HAA Request **
Off' Level at
Vent (Y/N)
Pumping Cycles during Adequacy Test. Meets MOA
I certify that I have checked, verified, or conformed to all MOA and HAA guidelines in effect on the date of this inspection.
Signed � Date
��`.�
Company / LLfLL - MOA No. ST 9S tiaK
Receipt No. '�� c:5 a�0 D
Date of Payment
Amount: $
.GiG YLG Qt�v'lc��
Page 2 of
72-026 (11iea)
h
CHEMICAL & GEOLOGICAL LABORATORIES OF ALASKA, INC.
TELEPHONE (907) 562.2343 ANCHORAGE INDUSTRIAL CENTER
t.swrt.,urx..
5633 B Street
Drinking Water Analysis Report for Total Coliform Bacteria
TO BE COMPLETED BY WATER SUPPLIER
WATER SYSTEM: F" see h on back
I.D. NO.
water System Name Phone No.
Mailing Address
City
State
SAMPLE DATE: 111J_a—t F-776
EaD-
Mo. Day Year
Zip Code
SAMPLE TYPE:
Routine
❑ Check Sample (for routine sample t ❑Treated Water
❑ Special Purposea
with lab ref. Untreated Water
SAMPLE Time Collected
NO LOCATION,( j Collected
r
3 I
4
5
READ INSTRUCTIONS
BEFORE
TO BE COMPLETED BY LABORATORY
Analysis shows this Water SAMPLE to be:
Satisfactory
❑ Unsatisfactory
❑ Sample too long in transit; sample should
not be over 30 hours old at examination to
indicate reliable results. Please send new
sample via special delivery mail.
Date Received r�
Time Received i2 r'
Analytical Method:
❑ Fermentation Tube
Membrane Filter
Lab Ref. No..� Result" Analyst
I I ED
�m
Fr -1
.No, of colonies/ 100 ml. or No. of Posrove portions
06.1220 (b) BACTERIOLOGICAL WATER ANALYSIS RECORD
Rev. 1963
Membrane Filter. Direct Count
Verification: LTB
Final Membrane Filter esults
Reported By L
BGB
✓ �.` i Date S
COLLECTING SAMPLE TNTC = Too Numerous To Count
Coilforml100ml
Collform/100ml
Time: Dy a.m.
p.m.
MUNICIPALITY OF ANCHORAGE 11
DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION
DIVISION OF ENVIRONMENTAL HEALTH
CERTIFICATE OF INSPECTION FOR HEALTH AUTHORITY APPROVAL
OF ON-SITE SEWER AND WATER FACILITY
264-4720
Application Date . ---
1. GENERAL INFORMATION
(a) Legal Description (include lot, block, subdivision, section, township, range)
Lot 4 Block 4 Rabbit Creek View Subdivision
Location (address or directions)
Genevieve Drive
(b) Applicant Name B. Wilson Telephone: Home __— Business _
Applicant Address 16100 Genevieve Drive —_—_
(c) Applicant is (check one): Lending Institution ❑ ; Owner/builder EF; Buyer ❑ ; Other ❑ (explain);
345-1-454
(d) Lending institution Westland Mortgage % Colleen Mq. 563-5150— —
Address 400 West Tudor Road, Anchorage, Alaska 99503
(e) Real Estate Company and Agent - -- --
Address — -- ---
Telephone--------
(f) Mail the HAA to the following address:
2. TYPE OF RESIDENCE
Single-FamilyUx Multi -Family ❑ Other — --- — -
Number of Bedrooms four (4)
3. WATER SUPPLY
Individual Well Ek Community ❑ Public ❑
Note: If community well system, must have written confirmation from the State Department of Environmental Conservation
attesting to the legality and status.
4. SEWAGE DISPOSAL
Onsite Ek Public ❑ Community ❑ Holding Tank ❑
Note: If community well system, must have written confirmation from the State Department of Environmental Conservation
attesting to the legality and status.
72-025 (11/84)
Page 1 of 2
5. NGINEERING FIRM PROVIDIN . INSPECTIONS, TESTS, FILE SEARCH, Da A AND INFORMATION
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health
Authority Approval shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained
from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or
wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on
the date of this inspection.
Name of Firm Telephone -
A`IA,r
Date --
6. DHEP APPROVAL
Approved foredrooms by � "--2.- _ _y--` � �^h _ Date
Conditional approval for four 4 bedroom
Engineer's Seal
August 9, 1985
Approved
Disapproved
Terms of Conditional Approval Monies to be escrowed to upgrade on-site sewer system as
per permit #850265 to meet MOA Requirements. Work to be completed no later
than September 9, 1985
;'��T➢-fl * Z
The Muncipality of Anchorage Department of Health and Environmental Protection (DHEP) issues Health Authority
Approval certificates based solely upon the representations given in paragraph 5 above by an independent professional
engineer registered in the State of Alaska. The DHEP does this as a courtesy to purchasers of homes and their lending
institutions in order to satisfy certain federal and state requirements. Employees of DHEP do riot conduct inspections or
analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the
professional engineer's work.
Page 2 of 2
72-025 (11/D4)
1
2.
3.
4.
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION
DIVISION OF ENVIRONMENTAL HEALTH
CERTIFICATE OF INSPECTION FOR HEALTH AUTHORITY APPROVAL
OF ON-SITE SEWER AND WATER FACILITY
2.644720
Application Date
GENERAL INFORMATION
(a) Legal Description (include lot, block, subdivision, section, township, range)
�® !// erg s A/ ,c% . 3Ga� ✓
Location (address or directions)
(b) Applicant Name ice— Telephone: Home -- Business
Applicant Address _____---
(c) Applicant is (check one): Lending Institution C1 ; Owner/buildey ; Buyer ®; Other ® (explain);
EE
(e)
(f)
Lending Institution =fir
Address ----
Real Estate Company and Agent
Address — —.-
Telephone — -----
Mail the HAA toAheJollowing,ad
TYPE OF RESIDENCE
Single -Family, Multi -Family ❑ Other
Number of Bedrooms --3--
WATER
3—
WATER SUPPLY
Individual Well VCommunity 0 Public
Note: If community well system, must have written confirmation from the State Department of Environmental Conservation
attesting to the legality and status. f'
SEWAGE DISPOSAL
Onsite Public Cl Community C] Holding Tank
Note: f community well system, must have written confirmation from the State Department of Environmental Conservation
attesting to the legality and status.
Page 1 of 2
Y4
ci
72-025 111184]
i
5. ENGINEERING FIRM PROVIDIN, INSPECTIONS, TESTS, FILE SEARCH, DA.A AND INFORMATION
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health
Authority Approval shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained
from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or
wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on
the date of this inspection. s
Name of Firm�s - Yr'�e�r tom_ Telephone _.__/✓t,
Address w® Id _-3
I Date
1 i.
Sr`°7`>t�>a� c�
" Ire- G�"'""�' �•c � � �� ��� �.�
lie
4
eal Y. n,evN"cHWN'O an Y0904 e9 090
A. 2251-E
'9b0evm0me• �,
�ROFESS
6. DHEP APPROVAL
Approved for —bedrooms by _ — — 4e ---62 --
Approved Disapproved _.__ Conditional w�
Terms of Conditional Approval _(
A.
Cit �s`d
The Muncipality of Anchorage Department of Health, and Environmental Protection (DHEP) issues Health Authority
Approval certificates based solely upon the representations given in paragraph 5 above by an independent professional
engineer registered in the State of Alaska. The DHEP does this as a courtesy to purchasers of homes and their lending
institutions in order to satisfy certain federal and state requirements. Employees of DHEP do not conduct inspections or
analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the
professional engineer's work.
Page 2 of 2
72-025 111: 84)
6
M -W Drilling, Inc.
*P.O. Box 110378*Anchorale, AK 99511♦
♦ 907-345-4000 ♦ 907-315-3287 Fax •
Job No.: 02-137 Project No.: N/A
Permit No. SW020189
Groundwater Well As -Built & Loz
♦ Well Owner. Boutet, Donna _ ♦ Use of Well: Domestic
♦Legal Description: Rabbit Creek View, Block 4, Lot 4
16100 Genevere- Anchorage, Alaska
Construction
♦Hole Depth: 205' ♦Casing Size: 6" *Cased To 37' #Material: A53Steel
♦ Dri11 Method. Air Rotary
Perf.
♦ Well Completion- Open end X Screen _ P srforated , Method.
*Screen/Perforation description: None
*GroutNotes. 10" Surface casing installed & pulled while grouting annulus with bentonite../4
• Notes: -40110 re S442,
♦ Well Development. Method: Air surge Note v.
#Static water level (SWL) 25' (ebove) (below) top t jcasing (TOC).
♦ Well yield test at 2.5 gallons per minute (GPM)/gallons per hour (GPH) for 1 hours
With 100% of drawdown (DD) from static level (SWL).
*Method: Air lift
#Date of completion: 25 June 2002 ►Pump Install. 26 June 2002
Well Log
Depth in feet from
top of casing. I Details of formations oenetrai ed, size of material; color and ! ardn=s.
0 TO 2 Casing stickup
2 TO 5 Topsoil
5 TO 17 Gravel: sandy, coarse
17 TO 20 Fractured bedrock
20 TO 205 Bedrock: gray/black, siltstone a-gillite, small water seaps in sporadic
TO fractures.
TO
TO
TO
TO
TO
TO
TO
TO Gam/
TO
TO
NWWA Cart9rteti Contractor
TO Certificate No's. 814 & "073
B9 io7
c 7�
2
Vi ' S� N�� A
,,,,/ i sig r '. •
G£• &
•ht Municipality of Ancho gee :. 7 2.017 `
On-Site Water and Wastewater Pro_ - ,;;,� a
, ;' .
(907)343-7904 / 5 s� c"^' s A F E T Y
6
ii
Certificate of On-Site Systems Appro o� 6 e L
Parcel I.D. 020-541-37 Expiration Date: . I -I 1
1. GENERAL INFORMATION
Complete legal description Rabbit Creek View and Heights, Block 4V, Lot 4A
Location (site address) 16100 Genevieve Street Anchorage, AK 99516
Current Property owner(s) Skye & Hilary Cooley Day phone 360-3875
Mailing address 16100 Genevieve Street Anchorage, AK 99516
Real Estate Agent Day phone
2. TYPE OF DWELLING:
[X] Single Family (w/wo ADU)
❑ Duplex
❑ Multiple Dwellings (Single Family and/or Duplex)
3. NUMBER OF BEDROOMS: Four
4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL:
Individual Well E Individual ID
Individual Water Storage ❑ Holding Tank ❑
Community Class Well ❑ Community ❑
Public Water System ❑ Public Sewer ❑
WaiverNariance request for: Distance:
Received by: S---h i4} Date: _WWIL.
COSA to be released to the engineer,unless otherwise requested by the engineer.
COSA Fee $ Szro — Waiver Fee $
Date of Payment "I I?- 1 11 Date of Payment
Receipt Number 0332JiC Receipt Number
COSA# �0...11 1329 Waiver#
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation,
based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application,
shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the information
obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water
supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes,
ordinances, and regulations in effect at the time of installation.
Name of Firm Anderson Engineering Phone 522-7773
Address 1399 West 34th Avenue No. 203 Anchorage, AK 99503
Engineer's Printed Name Michael E. Anderson, P.E. Date 7/27/2017
•
6. DSD SIGNATURE 1i e:;:t.
}C System #1 Approved for 1"( bedrooms MICHAEL E. ANDERSON
•• CE-4381 •••
J $.?
System #2 Approved for bedrooms 46���••;j-Z-7— �
i7.•���
Disapproved q4 pROFESSIO\sus
Conditional approval for bedrooms, with the following stipulations:
-�'0 UN-SITE 1-G,
WATFR AND
c---;, WASTEWATER c
PROGKAI`tiil
rc.
By: 4L Original Certificate Date: �-' 1
The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On-Site Systems Approval (COSA) based only
upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality
of Anchorage is not responsible for errors or omissions in the professional engineer's work.
7. ATTACHMENTS:
COSA Checklist X Nitrate Advisory
Septic System Advisory Arsenic Advisory
Well Flow Advisory Other
COSA blue sheet S .. c
If more than 1 septic system is on the lot:
COSA Checklist# of
Structure served by this system
Certificate of On-Site Systems Approval Checklist
Rabbit Creek View & Heights, Block 4V, Lot 4A 020-541-37
Legal Description: Parcel ID:
A. WELL DATA
Well type Private If A, B, or C provide PWSID# Well Log (YIN) Y
Date completed 6/25/02 Sanitary seal (Y/N) Y Wires properly protected (Y/N) Y
Total depth 205 ft. Cased to 37 ft. Casing height (above ground) X18 in.
FROM WELL LOG AT INSPECTION
Date of test 6/25/02 7/20/17
Static water level 25 ft. 38 ft
Well production 2'S g.p.m. 3'9 g p.m
WATER SAMPLE RESULTS:
Coliform 0 colonies/100 mL Nitrate 2.50 mg/L
Arsenic ND ug/L Date of sample: 7/10/17 0/17 Collected by: Anderson Engrg.
B. SEPTIC/HOLDING TANK DATA
Tank Type/Material Septic/Steel Date installed 8/11/15
Tank size 1 '250 gal, Number of Compartments 2 Cleanouts (Y/N) Y
Foundation cleanout (YIN) Y Depression over tank (Y/N) N High water alarm (YIN) N
Date of pumping 8/2/17 Pumper A+ Home Services
C. ABSORPTION FIELD DATA
Date installed 8/85 Soil rating (g p d./ft2 or ft2/bdrm) 138 SF/BDRM System type Shallow Bed
Length 47 ft. Width 18 ft. Gravel below pipe 5 ft.
Total depth 2.5 ft. Eff. absorption area 846 ft2 Monitoring tube Y Depression over field N
Date of adequacy test 7/20/17 Results (Pass/Fail) Pass For 4 bedrooms
2*
Fluid depth in absorption field before test in. Water added 600 gal. New depth 5*
in.
2*
Elapsed Time: 1 ,440 min. Final fluid depth in Absorption rate >= 600 g p d
Any rejuvenation treatment (past 12 mo.) (Y/N & type) N If yes. give date
*There are 3 monitor tubes in the absorption bed. No water was noted in the distribution pipe
during the test. The highest depth of fluid is recorded above. The system absorbs more than
600 gallons of water per 24 hour period.
D. LIFT STATION
Date installed Size in gallons Manhole/Access(Y/N)
"Pump on" level at in. "Pump off' level at in. High water alarm level at in.
Datum Cycles tested Meets alarm&circuit requirements?
E. SEPARATION DISTANCES
WELL ON LOT TO:
Septic tank/lift station on lot >100'
On adjacent lots >100'
Absorption field on lot >1 00' On adjacent lots >100'
Public sewer main >75' Public sewer manhole/cleanout 100'
Sewer/septic service line X25' Holding tank X75'
Animal containment areas >50' Manure/animal excrete storage areas 100'
SEPTIC/HOLDING TANK ON LOT TO:
>5' >5' >5'
Building foundation Property line Absorption field
10' 1 >100'
Water main Water service line Surface water
Wells on adjacent lots >100'
ABSORPTION FIELD ON LOT TO:
Property line 10 Building foundation 1 Water main
Water Service line 1 Surface water 100Driveway, parking/vehicle storage 1
Curtain drain None Noted Wells on adjacent lots >100'
F. COMMENTS
G. ENGINEER'S CERTIFICATION �' Or ACIU
iir4
1 certify that I have determined through field inspections and d�`%1' " *9.1'4�review of Municipal records that the above systems are in ,s Cl: c, ;
conformance with MOA COSA guidelines in effect on this date. �` •
Engineer's Printed Name Benjamin Schiller, P.E. ea
�.... ... .-..moo.
Date 8/7/2017 si,p'•, CE-1i5,92 t`'
#!4. 5. �er
COSA brown sheet 10-10-12.doc
Municipality of Anchorage
On -Site Water and Wastewater Program
(907) 343-7904 'tt�,
5ry41 Certificate of On -Site Systems Approval p—
Parcel I.D. 020- '-37 Expiration Date:
1. GENERAL INFORMATION UV 4�
Complete legal description Rabbit Creek View and Heights, Block 4A, Lot
Location (site address) 16100 Genevieve Street Anchorage, AK 99516
Current Property owner(s) Jacque & Donna BOutet
Mailing address
Real Estate Agent
Day phone 270-6761
9043 Snowy Owl Circle Anchorage, AK 99507
2. TYPE OF DWELLING:
R Single Family (w/wo ADU)
❑ Duplex
❑ Multiple Dwellings (Single Family and/or Duplex)
3. NUMBER OF BEDROOMS: Four
Day phone
4. TYPE OF WATER SUPPLY:
TYPE OF WASTEWATER DISPOSAL:
Individual Well
it
Individual
0
Individual Water Storage
❑
Holding Tank
❑
Community Class Well
❑
Community
❑
Public Water System
❑
Public Sewer
❑
WaiverNariance request
COSA Fee $ ���� A Waiver Fee $
Date of Payment ? 1l'1 � l5 t _ Date of Payment
Receipt Number N620(G1 Receipt Number
COSA# 05U51H3*� Waiver#
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation,
based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application,
shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the information
obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water
supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes,
ordinances, and regulations in effect at the time of installation.
Name of Firm Anderson Engineering Phone
Address P.O. Box 240773 Anchorage, AK 99524
Engineer's Printed Name Michael E. Anderson, P.E.
6. DSD SIGNATURE
System #1 Approved for —4 bedrooms
System #2 Approved for bedrooms
Disapproved
Conditional approval for bedrooms,
522-7773
Rale. 8/17/2015
♦SOF
'f' 1
9 *' *_*
I?,-- MICHAEL .E ANDERSON . o
CE -4381 ;\ a
with the following stipulationg.
By: � Original Certificate Date: R _ / q' /_
The. icipy orage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only
upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality
of Anchorage is not responsible for errors or omissions in the professional engineer's. work.
7. ATTACHMENTS:
COSA Checklist X Nitrate Advisory
Septic System Advisory Arsenic Advisory
Well Flow Advisory
COSA b,ue snee,S ..
Other
If more than I septic system is on the lot:
COSA Checklist # _of
Structure served by this system
Certificate of On -Site Systems Approval Checklist
syr
Legal Description: Rabbit Creek View & Heights, Block 4V, Lot 4A Parcel ID: 020-6.51-37
A. WELL DATA
Well type Private If A, B, or C provide PWSID # Well Log (Y/N) Y
Date completed 6/25/02 Sanitary seal (Y/N) Y Wires properly protected (Y/N) Y
Total depth 205 ft. Cased to 37 ft. Casing height (above ground) >18 in.
FROM WELL LOG AT INSPECTION
Date of test 6/25/02 8/12/15
Static water level 25 ft. 70.3
Well production 2.5 g.p,m, 4.4
WATER SAMPLE RESULTS:
WE
9 -
p.m -
Coliform 0 colonies/100 mL Nitrate L-) lSmg/L
Arsenic AID ug/L -Dateofsample: 8/5/15 Collected by: And. Engineering
B. SEPTICIHOLDING TANK DATA
Tank Type/Material Septic/Steel
Tank size 1,250 gal. Numberof Compartments 2
Foundation cleanout (Y/N) Y Depression over tank (Y/N) N
Date of pumping New Const. Pumper
C. ABSORPTION FIELD DATA
Date installed 8/11/15
Cleanouts (YIN) Y
High water alarm (Y/N) N
Date installed 8/85 Soil rating (g.p.d./f:2 or ftz/bdrm) 138 sr/BDRM System type Shallow Bed
Length 47 ft. Width 18 ft. Gravel below pipe .5 ft.
Total depth 2.5 ft. Eff. absorption area 846 ftZ Monitoring tube Y Depression over field N
Date of adouaG'y test 8/12/1:5 Results (Pass/Fail) Pass For 4 bedrooms
Fluid depth in absorption field before test 0 in. Water added 921 gal. New depth 5 in.
Elapsed Time: '1;440min. Final fluid depth 0 in. Absorption rate >= 600 g P d
Any rejuvenation treatment (past 12 mo.) (Y/N & type) N If yes, give date
D. LIFT STATION
Date installed Size in gallons Manhole/Access (Y/N)
"Pump on" level at in. "Pump off" level at in. High water alarm level at
Datum Cycles tested Meets alarm & circuit requirements?
E. SEPARATION DISTANCES
WELL ON LOT TO:
Septic tank/lift station on lot >100 On adjacent lots >100
Absorption field on lot >100' On adjacent lots >1 00'
Public sewer main >75 Public sewer manhole/cleanout >100
Sewer/septic service line >25 Holding tank >75
Animal containment areas >50' Manure/animal excrete storage areas >100,
SEPTIC/HOLDING TANK ON LOT TO:
Building foundation >51 Property line >51
,
Water main >10' water service Zine >10'
Wells on adjacent lots >100'
ABSORPTION FIELD ON LOT TO:
Property line >10, Building foundation >10'
Water Service line >10' Surface water >100'
Curtain drain None Noted Wells on adjacent lots >100,
F. COMMENTS
G. ENGINEER'S CERTIFICATION
I certify that 1 have determined through field inspections and
review of Municipal records that the above systems are in
conformance with MOA COSA guidelines in effect on this,date.
Engineer's Printed Name Michael E. Anderson, P.E.
Date 8/17/2015
COSA brown sheet_1010-12.doc
Absorption field >51
Surface water >100'
Water main N/A
Driveway, parking/vehiclestorage >10,
0
c:t-asst
A.� -17-
� �pR4FE5510�AA:
1
LOT 1 A k k EAT 2A
tit
k
i
k
LOT 3A k
k
6
k
k
LOT 5A 1
k
I
10' UTILITY EASEMENTS a
:c -779'x11.7'
i SHED
ZO
Ve'T1
>Ikk{'7.
DECK
PES 330 Qs.5,
8.3' DECK : {
k5.5'x16.3' BALCONY- i
k LOT 4A
6t
k30,761 8.t. ,-2
�
STORY
,r ...LLL������������ €° FULL BSMT.
RESIDENCE—J
kWOODEN FENCE �
I S \3'41557 187.16`
LOO l 6A
I
{
PLOT PLAN ____ AS BUILT X SCALE 1" - 40' GRID SW 3241 Project No.15-201jA3
t • � ♦ t E.- aft r. ,r. -
:.x
f
r
i ��.
La-
LLJ�
a
� �
22.3'
.., V
Y \i
W
m
2.0'
u tad
z
CANT LU
ca [
�,-6'I41--GAS
10'x20` NATURAL
EMENT
{
PLOT PLAN ____ AS BUILT X SCALE 1" - 40' GRID SW 3241 Project No.15-201jA3
t • � ♦ t E.- aft r. ,r. -
:.x
f
r
i ��.