HomeMy WebLinkAboutHOMAN ACRES LT 1Homan Acres Lot 1 #015-271-52 Municipality of Anchorage On -Site Water and Wastewater Section - (907) 343-7904 Page of ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP241350 PID Number: 015-271-52 Dwelling: Z Single Family (SF) R with ADU R Duplex (D) El Two Single Family Project: El New Z Upgrade Name LAURA J BONNER ABSORPTION FIELD El Deep Trench ®Wide Trench R Bed R Mound Site Address 112TH 3101 E 112 AVENUE, Anchorage El Other Phone Number of Bedrooms Soil Rating1 otal depth from original grade 3 1.2 GPD/SFT *8 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade 6 Ft. Gravel depth beneath pipe 2 Ft. Subdivision Block Lot HOMAN ACRES 1 Fill added above original grade VARIES 05— 2.1 Ft. Gravel length 53 Ft. Township Range Section Gravel width 5 Ft. Beds: Number of Lines Distance between lines Ft. SEPARATION DISTANCES To! Septic Absorption Holding Sewer l Total absorption area Number of trenches Dist. between trenches Tank Lift Station From Field Tank Line 375 F t2 1 Ft, Well 100'+ 100'+ 25'+ TANK Z Septic 0 S.T.E.P. 171 Holding 0 Other Manufacturer GREER Capacity 1000 Gal. Surface Water 1100'+ i 100'+ Material HDPE Number of compartments 2 Lot Line 1 5'+ 1 10'+ NA Foundation 10'+ 10'+ LIFT STATION Manufacturer Capacity Gal. Remarks Deep -Burial HDPE tank. *Able to elevate & install trench to a total depth of 8' from original grade Win the same soil strata. Alarm location Electrical installed by PIPE MATERIAL House to tank 3034 drainfield Tank to 3034 Installer __ Drainfield 3034 CO/MT3034 Inspector FWC BENCH MARK (Assumed elevation) 100 ft Inspdates: 15` 2/24/25 „d 2/24/2025 Location and description 2ection Yd 2/26/25 4'h 4/21/2025 BOTTOM OF SHOP SIDING ON-SITE WATER AND WASTEWATER SECTION APPROVAL Aw A Conditional Approval: Date AWAMW 7H Septic Syste Curtis Huffman 0.4�. Approved - CE 128991 •-,q A1W Date .94/04/2 5. . Amw ote: this approval does not include well permit requirem nts. (Rev 05/02/1'8) 25 . 3 ' 36. 6 ' LOT 1 49,950 sq. ft. 10 ' U T I L I T Y E A S E M E N T N 0 0 ° 1 2 ' 4 8 " W 3 3 3 . 0 0 ' LOT 5 UTILITY POLES 0 0 ° 1 2 ' 4 8 " E 3 3 3 . 0 0 ' SH E D LO T 1 SHOP LOT 2 PID:015-271-52 PERMIT:OSP241350 FIRST WATER CONSULTING HOMAN ACRES LOT 1 MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite On -Site Wastewater Disposal System Permit Permit Number: OSP241350 Work Type: Septic Upgrade Tax Code Number: 01527152000 Site Legal Address: HOMAN ACRES LT 1 G:2634 Site Mailing Address: 3101 Ell2TH AVE, Anchorage Owner: BONNER LAURA J LIVING TRUST Design Engineer: FIRST WATER CONSULTING This permit is for the construction of: Effective Date Expiration Date: Lot Size in Sq Ft: Total Bedrooms: 10/30/2024 10/30/2025 49950 Q Disposal Field ❑ Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Received By: Issued By: �- Date: 3 Date: 0 -3 2v z.7 MUNICIPALITY OF ANCHORAGE Development Services Department Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 ON -SITE SEPTIC/WELL PERMIT APPLICATION Parcel I.D. 015-271-52 Property owner(s) BONNER LAURA J LIVING TRUST Day phone Mailing address 3101 E 112TH AVENUE, ANCHORAGE, AK 99516 Site address 3101 E 112TH AVENUE, ANCHORAGE, AK 99516 Legal description (Sub'd., Block & Lot) HOMAN ACRES LOT 1 Legal description (Township, Range & Section) Lot Size 49,950 Sq. Ft. Number of Bedrooms 3 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (Z all that apply) Absorption Field Initial ❑ Single Family (SF) (w/wo ADU) Septic Tank 0 Upgrade Duplex (D) ❑ Holding Tank ❑ Renewal Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑ Water Storage El THIS APPLICATION INCLUDES A WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of -property, owner or authorized agent) Permit/Rush Fees:. 0 Waiver Fees: Date of Payment: to Date of Payment: Receipt Number: Receipt Number: Permit No. 0-522HL350 Waiver No. GADevelopment Services\Building Safety\On Site Water and WastewaterTormsUient Forms\Permit Application.doc 13030 Sues Way, Anchorage, AK 99516 907-350-9566 / firstwaterAK@gmail.com ! !! October 17, 2024 Municipalities of Anchorage On-Site Water & Wastewater Program 4700 Elmore Road Anchorage, AK 99507 RE: SEPTIC SYSTEM UPGRADE PERMIT LEGAL: HOMAN ACRES LOT 1 The property owner has requested we obtain a permit to upgrade the failed septic system of the above referenced lot. We propose to install one shallow trench and reconnect to the existing septic tank to serve the existing 3-bedroom residence. The design is based on the recent test hole conducted on October 8, 2024. No groundwater was observed at test hole excavation or monitoring. The slopes are moderate at 0-3% at the proposed upgrade location. The lot and area are served by private water. The design will not impact any of the neighboring properties. Please contact us if you have any questions. Sincerely, Curtis Huffman, P.E. Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP241350, Curtis Townsend, 10/30/24 LOT 1 49,950 sq. ft. 10 ' U T IL I T Y E A S E M E NT SHED 30 ' REBAR REBAR W/CAP OV E R H EA D UT I L IT Y L I N E WELL N 0 0 ° 1 2 ' 4 8 " W 3 3 3 . 0 0 ' N 90°00'00" E 150.00' LOT 1 SHED 30 ' LOT 5 112TH AVENUE UTILITY POLE S 0 0 ° 1 2 ' 4 8 " E 3 3 3 . 0 0 ' 3' ROAD AND UTILITY EASEMENT APPROX WELL APPROX WELL DRIVE 3BR HOUSE SHOP FIRST WATER CONSULTING HOMAN ACRES LOT 1 DESIGN CALCS: NO WELLS WITHIN 100' OF PROPOSED SEPTIC FIELD NO SLOPES >25% WITHIN 50' OF PROPOSED FIELD. Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP241350, Curtis Townsend, 10/30/24 25.3' 36. 6' FIRST WATER CONSULTING HOMAN ACRES LOT 1 10 ' UT I L ES M T LOT 5 LOT 1 HOMAN ACRES LOT 1 NO WELLS WITHIN 100' OF PROPOSED SEPTIC FIELD DESIGN DETAILS: Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP241350, Curtis Townsend, 10/30/24 3030 Sues Way - Anchorage, Alaska 99516 Tel. 907-350-9566 firstwaterAK@gmail.com SOILS LOG - PERCOLATION TEST LEGAL : HOMAN ACRES LOT 1 PERFORMED BY: FWC - I CURTIS HUFFMAN CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE & MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: 10/16/2024 DEPTH FEET OG SOILS 1 2 ORG/OL 3 4 5 6 SM/sp 7 8 9 10 11 12 13 14 15 16 17 18 BOH 19 20 Reading Date Gross Time Net Time Depth to Water Net Drop 10/08/24 10 min 6” 3 15/16” “ 6” 3 14/16” “ 6” 3 14/16” “ 6” 3 13 /16” “ 6” 3 13 /16” “ 6” 3 13 /16” PERCOLATION RATE 2.6 (MIN / INCH) TEST RUN BEWTWEEN 5 & 6 FT PERC HOLE DIAMETER 6” PRE-SOAKED PRIOR TO TEST & ALL READINGS TO THE 1/16TH. GROUND WATER ENCOUNTERED: NO IF YES, AT WHAT DEPTH: NA DEPTH TO WATER AT MONITORING: DRY DATE: 10/16/2024 TESTHOLE # 24-1 DATE PERFORMED: 10/08/24 SEE SITE PLAN FOR SLOPE & LOCATION COMMENTS: VERIFY GROUNDWATER MT AT TIME OF CONSTRUCTION PERFORMED FOR: LAURA BONNER 10/16/24 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP241350, Curtis Townsend, 10/30/24 N 90000'00" W 150.00' LOT 2 LOT 5 �o ql r< C < _ r rm D I m. �I m DI Cn m �I m zl C I C L UTILITY Q o POLE W m W W I W O O LOT 1 49,950 sq. ft. SEPTIC STANDPIPES (rl LOT SHED SEE BUILDING ' 43.2' x� DETAIL SHEDO x I } 53.4' LL 50.1' 3' ROAD AND I I _ GRAVEL DRIVEWAY UTILITY I W WELL o EASEMENT / N REBAR 0 --x N 90 000'00" E 150.00, Co 112TH AVENUE — — k 61 4U N' 1-STORY FRAME % HOUSE N /36 61 CNbMNFY l :. v� 0 4p 0' N 2-STORY DECK FRAME HOUSE 4.01 GRAVEL DRIVEWAY �ccNCRETF. BUILDING DETAIL 1" = 30' IRON PIPE 0 M EASEMENTS OF RECORD, OTHER THAN THOSE SHOWN ON THE RECORDED SUBDIVISION PLAT (73-166) ARE NOT SHOWN HEREON. THIS DOCUMENT DOES NOT CONSTITUTE A BOUNDARY SURVEYAND IS SUBJECT TO ANY INACCURACIES THATA SUBSEQUENT BOUNDARY SURVEY MAY DISCLOSE. UNDER NO CIRCUMSTANCES SHOULD ANY OF THE DATA HEREON BE USED FOR CONSTRUCTION OF FENCES, IMPROVEMENTS, OR FOR II O O N 000 W W W O O REBAR W/CAP IV 0 25' 50' AS -BUILT I HEREBY CERTIFY THAT I HAVE SURVEYED THE FOLLOWING DESCRIBED PROPERTY: LOT 1, HOMAN ACRES SUBDIVISION ANCHORAGE RECORDING DISTRICT, ALASKAAND THAT THE IMPROVEMENTSAS DEPICTED HEREON EXISTAS SHOWN IN RELATION TO THE PROPERTY LINES. DATED THIS 1st DAY OF OCTOBER, 2024, AT ANCHORAGE, ALASKA. ESTABLISHING PROPERTY BOUNDARIES. FIXED HEIGHT LLC f C.O.A.122554 Land Surveying Services WWW.FIXEDHEIGHT.COM JOB # 24233 1 NO CORNERS SET THIS DATE I SCALE 1" = 50' 1 600 W 41st. Ave, Ste. C, Anchorage, AK 99503 907.290.8949 Municipality of Anchorage • .. Development Services Department It Building Safety Division On -Site Water & Wastewater Program, 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 3437904 Page 1 of 3 On -Site Wastewater Disposal System and/or Well Inspection Report �1 Permit Number.-'%Lznq CAtz PID Number. Name: LESTER AND LAURA BONNER Wastewater System: ❑ New ■ Upgrade Address: 3101 EAST 112" a ANCHORAGE, AK. 99516 ABSORPTION FIELD Phone: No. of Bedrooms: (907) 349-1183 3 D Daap Trench ■ Shallow Trench Deed D Mound O ether LEGAL DESCRIPTION �" "°'"` 1 2 TWd o.pn rem 010 MAX MIS, n. n. Block: Lot: Subdivision: — 1 HOMAN ACRES own to pa eWl" ham "inW goer Gro* dWh W.0 eloo: SEE DWG. n. 3.0 rL Township: — Range: Section; la eeeed aeo.e "l w Vaft. Gael knget: — — SEE DWG. n. 53 FL WELL: ❑ New ❑ Upgrade arpsl wee MWnMr of ww ablance seteewr error 5 n. 1 _ T< CbwAieoti0n FYwle. Ae.c): ToIW coved 1wastw000 Told eMwoaon par Vqo Ineterlon \r1C' n n. stone Mal; Leval: 457+ so. Mt~ n D 3034/ F-810 Dote Y,otWW: OrtMor: vote Orwrd: GEG, Ltd. 10/15/2004 R Yhle: poral .Set AL cas"9 NWgM Alw,e aroontt: ave R FL TANK SEPARATION DISTANCES ■Septic 0Holding 0S.T.E.P. 0Other To rrom Septic Tank Absorption Field Uft station Holding Tank ie/Prhate Sew; ts,.. Yp1N1IOCl'"'r ANCHORAGE TANK c' ity 90l 1000 Well too'+ too'+ — — 25'+ Na«w STEEL annrnw:Well 2 Surface water 100'+ too'+ — — — LIFT STATION Lot Line 5'+ to'+ — — _ s'r' In 9p Naaal«lp..: Foundation 5'+ 10'+ — — — en Y w,o of eH of N'ph Mar Warm W: Curtain Drain NONE KNOWN e Yo°a : ErWrka kwpoclb Wormed or. Remarks: BENCH MARK OLD SEPTIC TANK WAS ABANDONED PER UPC. BOTTOM OF GARAGE MAN DOOR ON NORTH SIDE. Aoeunwd EM.olen 100.00 st ENWNEE" SEAL Cr`.sr-�0 Inspections performed by: GEG, Ltd. Dates: 1st 10/15/200a *�', 2nd 10/15/2004 0 3rdof G rness. O Development ervices Department Approval E— 3 �p44o Reviewed and approved by Date: 1L/ f� Profesg,ano6cov 0400000 PERMIT NUMBER: AS -BUILT DRAWING 100' WELL RADIUS I � I I I � DBL1 29.96 14.52 DBL2 30.30 15.56 Sit 38.91 31.38 ST2 42.86 37.18 DBL3 44.52 39.90 DBL4 45.39 41.00 COI 116.22 97.93 VT 118.10 99.96 CO2 136.49 130.67 MT2 138.85 132.84 J I NEW DRAINFIELD CSIEPTIC AR S�D I OLD SEPTIC SYSTEM -�iTM/l+ I(COMPLETELY ABANDONED) 0 PARCEL ID ^"I I I I Imo\ ) I BL4 I I I I I BL3 I I I \ r/ -EXISTING SHOP DBLI Joo �y / I I I I I I Exh WELL �f I I I I W RI I I -- ---� L----- ----- I -- --- _ . DATE: --T 10/26/2004 0 F 0 P � F D DRAWN BY: ,( 0...V4O R.A.L. 0 GARNESS ENGINEERING GROUP, Ltd. Ste: a�C/)'*4 yp . CONSULTANTS i GENERAL CONTRACTORS „ _ e , 0 !*,:, ,,, , • . • • • •. '• 0 0 5701 F TMO ROM, SURF 101 • ANCHMAGF. A5 90507 • FHONF (007)JA-6VV • FA%(00))]}9.:46 1 = 50 0 • • • D PREPARED FOR: PHONE NUMBER: PAGE NUMBER: Q Q LESTER AND LAURA DONNER (907) 344-7488 2 OF 3 et .. ss - LEGAL. DESCRIPTION: y, 79 3 HAMMAN ACRES SUBDIVISION; LOT 1, n TYPE OF WORK: O�LL 4eV PFo le Qny V�o(�0 AS -BUILT FOR NEW SEPTIC SYSTEM �040000��Q I PERMIT NUMBER: ' i ne 17 _� AS -BUILT DRAWING PARCEL ID NUMBER: TOP OF TANK AT INLET . 95.19 INVERT OF BUNG AT INLET - 94.63 STI ORIGINAL GRADE 99.80 O HIGHEST POINT n La NEW 1000 GALLON SEPTIC TANK —�--GROUNE ELEVATION SOF T LL; --RELATIVE IN TEST HOLE O 84.10 RELATIVE ELEVATION OF BOTTOM OF TEST HOLE O 83.50 GARNESS ENGINEERING GROUP, Ltd. CONSULTANTS& GENERAL CONTRACTORS 3701 F. TUDOR ROAD. SURF 101 • AN[HORAGF. AK 00507 • M F (007)337-0170 • FAX (007)338d7A8 PREPARED FOR: PHONE NUMBER: LESTER AND LAURA BONNER (907) 344-7488 LEGAL DESCRIPTION: HOMAN ACRES SUBDIVISION; LOT 1. TWE OF WORK: PROFILE AS—BUILT OF SEPTIC SYSTEM UPGRADE ST2 1NAL GRADE 99.14 100.11 FABRIC N—INVERT OF PIPE 93.27(AVG.) BOTTOM OF TRENCH - 90.30(AVG.) 10/26/20 AWN BY: R.A.L. kLE: 1"=40' ;E NUMBER: 3OF3 TOP OF TANK AT OUTLET - 95.20 VERT OF BUNG AT OUTLET - 94.38 MUNICIPALITY OF ANCHORAGE �G Development Services Department On -Site Water& Wastewater Program 101t5��� 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Upgrade Date Issued: Nov 01, 2004 Expiration Date: Nov 01, 2005 Permit Number: SW040465 Parcel ID: 015-271-52 Legal Description: ,HOMAN ACRES LT 1 Design Engineer: 0855 Gamess Engineering Group, LTD Site Address: 003101 112TH AVE E Owner Name: LESTER & LAURA BONNER Lot Size: 49950 SO. FT. Owner Address: 3101 E 112TH AVE Total Bedrooms: 3 Permit Bedrooms: 3 ANCHORAGE. AK 99516-1425 This permit is for the construction of: ❑✓ Disposal Field ❑✓ Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction must be In accordance with: 1. The attached approved design. 2. All requirements specked in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72 ) and Drinking Water Regulations (18AAC80 ). 3, The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received By - Date: Municipality of Anchorage • Development Services Department Building Safety Division On -Site Water & Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us cCIS (907) 343-7904 b (t 61 OLA ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. W - 5' 1 Permit Number j e;-VrJ Property owner(s) LFSTF7R & LAURA BONNER Day phone 240-8430 Mailing address (1) 3101 EAST 112th AVENUE ► ANCHORAGE. AK Mailing address (2) Zip Code 99516 Legal description (Lot, Block & SuVd.) LOT 1: HOMAN ACRES SUBDIVISION Legal description (Section, Township & Range), Lot Size 4: 41 5b Acre Sq.Ft. THIS APPLICATION IS FOR: Number of Bedrooms 3 Sewer Only 0 Well Only ❑ Sewer and Well ❑ Water Storage ❑ Sewer Upgrade ❑ THIS PROPERTY CONTAINS: Hot Tub ❑ Jacuzzi ❑ Swimming Pool ❑ Water Softening Unit ❑ Therapy Pool ❑ I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal codes. GARNESS ENGINEERING GROUP, Ltd. _ �//S.Od S•�1Qt.�ts htuLa. ���r(��( Permit Fees: ��l�J Waiver Fees - Date of Payment: ffbrlo { Receipt Number. t!ht)a 04— Date Date of Payment: Receipt Number. GARNESS ENGINEERING GROUP, Ltd. CONSULTANTS & GENERAL CONTRACTORS June 13, 2004 Municipality of Anchorage Development Service Department Building Safety Division On -Site Water & Wastewater Program P.O. Box 196650 Anchorage, Alaska 99519-6650 Ref: Proposed Septic System upgrade for Homan Acres Subdivision, Lot 1 To whom it may concern: The existing 3 -bedroom house is served by a private well and septic system. The septic system is failed and must be replaced. A test hole was excavated on the property. The drainfield will be designed around the 30 -foot radius of this test hole. We are proposing that a new 1000 -gallon septic tank and a deep trench type drainfield be installed. Comments regarding the design are summarized as follows: 1. SOILS: See the attached log, which shows the soil classifications, groundwater monitoring, and the percolation test results. It is our opinion that due to the overall appearance of the soils, an application rate of 1.0 gallons/day/R2 should be used. 2. TRENCH DESIGN: a. Percolation Rate: 2.9 minutes/inch b. Proposed Application Rate: 1.0 gallons/day/ft2 c. Number of Bedrooms: 3 d. Design Flow: 450 gallons per day e. Minimum Absorption Area: 450112 f. Total Depth: 9.5 feet (max.) g. Effective Depth: 4 feet h. Width: 5.0 feet i. Reduction Factor: 0.50 j. Minimum Length: 50 feet long total k. Effective absorption area = 500 fl2 3. SURFACE WATERS: There are no surface waters within 100+ feet of the proposed septic system. 3701 E. Tudor Road, Suite 101 • Anchorage, AK 99507 Ph: (907) 337-6179 0 Fax: (907) 338-3246 • Website: gamessengineering.com 4. TOPOGRAPHY: As can be seen on the attached topography site plan, the average topography in the area of the proposed drainfield is relatively flat. In short, there are no slope concerns. I am unaware of any adverse impacts this installation would have on adjacent wells or septic systems. If you have any questions, please contact us at 337-6179. Thank you for your assistance. .E., M.S. NOTE: Attached is a site plan drawing, a design drawing, a topography site plan, a soils log, and a 7 page construction specification letter which are all part of the design package for this septic system. 3701 E. Tudor Road, Suite 101 *Anchorage, AK 99507 Ph: (907) 337-6179 • Fax: (907) 338-3246 • Website: gamessengineering.com _CHRIS CIRCLE PTARMIGAN NEW ESTATES; LOT 5 I I I I I I I I I I 1 HOMAN ACRES; LOT 2 1 � PROPOSED SEPTIC PTARMIGAN NEW\ESTATES: LOT 4♦♦ ♦♦♦ j I UPGRADE. SEE �00 PPREOX MDIUS I ♦♦♦�J�._l j^�P�E DESIGN. FOR / I 1C EP IC ARIA 1 rTpT1 I 1 —7 I � I iTH/t j6AERFAS -I----��-41 ' i 1 � I ♦ A PTARMIGAN NEW ESTATES; LOT 3 1 1 < 1 / I I ♦ I j j s �/ i i ♦♦ PTARMIGAN NEW ESTATES; LOT 21 1 1 1 t 100' ELL RADII ----I-----------L.--j L---�-- 7/7/2004 _. ..._. .._ -.._, DRAWN BY: M.E.W GARNESS ENGINEERING GROUP, Ltd. SCALE: CONSULTANTS i GENERAL CONTRACTORS 1 = 1 GG• 1101 F Tl F+ 0OA0. (rnic 101 • ANr NOOAr,0 AK 00501 . FNONF MAtq}1-Aq0 • FAX (0A1AKA-]J6A PREPARED FOR PHONE NUMBER: PAGE NUMBER: LESTER do LAURA BONNER 344-7488 1 OF 2 LEGAL DESCRIPTION: HOMAN ACRES SUBDIVISION; LOT 1 TYPE OF WORK: SITE PLAN FOR PROPOSED SEPTIC UPGRADE I I I I I I I I I \I 1 1 I 419 ��♦ I j �- i 1 I I DAS ACRES; LOT to 1 I c I SEPTIC AR b I I CAS ACRES; LOT 16 EXISTING SHOP WfjFi BEDROOM I ♦ T-7DLISRNG TWO ♦� I BEDROOM HOUSE II I 100' WELL RADIUS_ I i i i r A. Crn s a —795 .` /o 100' WELL RADIUS I SWILL HAVE NOT&EAST THT LINE AND THE 100'IUS :jCONTRACTOR FLAGGED BY A REGAND SURVEYOR PRIORTONSTRUCTION. PROPOSED DRNFIELD: EXCAVATE A TRENCH THAT IS 9.5 FEET DEEP MAXIMUM. BY 5 FEET WIDE• I \ I BY 50 FEET LONG. ADD 4 FEET 9F CLEAN WASHED SEWER 1' \ \ I / DRNNROCK. I I — — — � J INSTALL I CLEANOUTS I [SEPTIC ARE�D I PR POSSEDR 100KCALLON ,'� TH11 I I I I ;� 11 -� EXISTING SEPTIC BO'+/- TANK TO BE COMPLETELY 70'+/- INSTALL ABAONDONED. FOO EXISTING SHOP I I WITH BEDROOM - -----� 120. WELL L----- ---- -- -- Q� or 7/7/2004 _q0 �C pF N 140 DRAWN BY: e O �!...... GARNESS ENGINEERING GROUP, Ltd. M.E.w yQpp CONSULTANTS 8 GENERAL CONTRACTORS S)01 F TI1009 009 $i IITF 101 • ANfuOF�LF AY 0050) • FNpNF (OOHS])-M)0 • FA% 10p)UW-0)46 SSE _ 50• 1" ,I lY�n PREPARED FOR: PHONE NUMBER: PAGE NUMBER: LESTER & LAURA BONNER (907) 344-7488 2 OF 2D -..Jl ffr C 0 1 p y ess. Q g. ' . 953 :O Q '' LEGAL DESCRIPTION: HOMAN ACRES SUBDIVISION; LOT 1 n°� • ��� �4��Qdp•ofeeslono�� 040000 TYPE OF WORK: DESIGN OF PROPOSED SEPTIC SYSTEM UPGRADE M GARNESS ENGINEERING GROUP, Ltd. �: f CONSULTANTS A GENERAL CONTRACTORS it 1 r&,A ME 101 • AN0 WDL A •N07 • . •0 -•1]• • F". N N YfitR pr�rgYrM1g9vn . SOIL LOG — PERCOLATION TEST LEGAL DESCRIPTION: HOMAN ACRES SUBDIVISION; LOT 1 OO 9 '•.J ffr PERFORMED FOR: LESTER k LAURA BONNER DATE: 6/26/2004 QQQ�� --., 40 (f � et »yam TEST HOLE 1 � 1 =y�y ORG 6/26/2004 15.7' 8 . TH/1 — SOIL CLASSIFICATIONS 2 2 11:29 10 .5' r `oma o GWORG 9 11:29 r ` GP ML 3 - 10 11:39 Tco GM CL 4 11 GC OL - 6' SW MH 5 11:49 •' ••• 'SP CH 2' 4' SM X: OH 11:49 - SC 7 DATE SMALL WEEP O 12' 6/26/2004 15.7' 8 . TH/1 — 6' — 2 11:29 10 .5' SM 9 11:29 - 6' - 10 11:39 Tco 1 1' 5' 11 � - 6' - 12 1111111 11:49 10 2' 4' 18 19 DEPTH TO GROUNDWATER DATE SMALL WEEP O 12' 6/26/2004 15.7' 7 5/2004 . TH/1 — 6' — DATE READING PERCOLATION I NET TIME (MINUTES) WATER LEVEL READING NET DROP (INCHES) 6/28/2004 1 . TH/1 — 6' — 2 11:29 10 .5' Cao 3 11:29 - 6' - 4 11:39 Tco 1 1' 5' 1 � - 6' - 6 11:49 10 2' 4' 7 11:49 - 6' - 8 11:59 10 2 1/8- 3 7/8- 8'9 9 11:59 - 6' - 10 12:09 10 2 1/20 3 1 2' 11 12:09 --I-- RAVI IS ----- i-- 1 E E---�-� - SITE PLAN 10-100, DATE READING PERCOLATION CLOCK TIME NET TIME (MINUTES) WATER LEVEL READING NET DROP (INCHES) 6/28/2004 1 11:19 — 6' — 2 11:29 10 .5' 5.5' 3 11:29 - 6' - 4 11:39 10 1 1' 5' 5 11:39 - 6' - 6 11:49 10 2' 4' 7 11:49 - 6' - 8 11:59 10 2 1/8- 3 7/8- 8'9 9 11:59 - 6' - 10 12:09 10 2 1/20 3 1 2' 11 12:09 - 6' - 12 12:19 10 2 1/2* 3 1/2 - 2 PERCOLATION RATE 2.9 (MIN./INCH) PERC. HOLE DIA. 6 (INCHES) TEST RUN BETWEEN 6.5 FT. AND 7.0 FT. 20 A FOUR HOUR PRESOAK WAS PERFORMED: N YES ❑ NO SOILS LOGGED BY: KELLY HEnMMAN PERCOLATION TEST PERFORMED BY: ROB CAMPBELL COMMENTS: PERFORMED BY GEG, Ltd. I, JEFFREY A. GARNESS, CERTIFY THAT THIS WASERF MED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: Z 0 NAME LOCATION SEPTIC TANK: GRr`�ER ANCHORAGE AREA BOA 1GH Department of Environmental Quality 3330 C Street Anchorage, Alaska 99503 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM MAILING ADDRESS PHONE LEGAL DESCRIPTION DISTANCE// ,� NUMBER OF / FROM WELL MANUFACTURER1 0 �2 MATERIAL COMPARTMENTS INSIDE LENGTH INSIDE WIDTH LIQUID DEPTH LIQUID CAPACITY GALLONS. SEEPAGE PIT: o? /I NUMBER OF PITS / DIAMETER w OR WIDTH (0 / LENGTH—, DEPTH �z 0 LINING MATERIAL P cP CRIB SIZE: DIAMETER_DEPTH DISTANCE FROM: WELL � / TOTAL EFFECTIVE BUILDING FOUNDATION -Y-69 96, NEAREST LOT LINE. ABSORPTION AREA (WALL AREA)SQ. FT. ADDITIONAL ABSORPTION WELL: TYPE CONSTRUCTION BUILDING NEAREST FOUNDATION—,LOT LINE CESSPOOL—,OTHER SOURCES APPROVED DISTANCES: INSTALLED BY: PIPE MATERIAL: UlM1ii: NEAREST SEPTIC SEWER LINE TANK_ DISAPPROVED REMARKS LOT SLOPE: "zt t " REMARKS: `6 c V� DIAGRAM OF SYSTEM DISTANCE FROM: SEEPAGE SYSTEM _ * Arn 11 1111// F NAME OF APPLICANT INSTALLATION LOCATION LEGAL DESCRIPTION (T> GREATER ANCHORAGE AREA BOROUGH DEPARTMENT OF ENVIRONMENTAL QUALITY PERMIT NO. 3330 "C" STREET ANCHORAGE, ALASKA 99503 TELEPHONE 274-4561 SEWAGE DISPOSAL SYSTEM - APPLICATION AND PERMIT INSTALLATION OF: SEPTIC TANK TYPE AND SIZE OF FACILITY TO BE SERVED 5� �, A MAILING h" L--� SEEPAGE PIT PHONE DRAIN FIELD OTHER FINANCED THROUGH � TO BE, INSTALLED BY SOIL TEST RESULTS `NOTE HIS PERMIT IS NOT VALID WITHOUT SOIL TEST COMPLETION DATE ANTICIPATED FINAL INSPECTION: 24 HOUR NOTICE REQUIRED. BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION BY THE DEPARTMENT OF ENVIRONMENTAL QUALITY AUTHORITY WILL BE SUBJECT TO PROSECUTION. SEPTIC TANK TYPE MINIMUM DISTANCES, REQUIREMENTS r � FOUNDATION TO SEPTIC TANK =7 FOUNDATION TO SEEPAGE PIT 21 DRAIN FIELD SEPTIC TANK TO SEEPAGE PIT WALL !' r `/ SEPTIC TANK '� SEEPAGE PIT LDRAIN FIELD TO NEAREST LOT LINE. WELL TO SEPTIC TANK /`" `�",, SEEPAGE PIT DRAIN FIELD ALSO CONSIDER AREA WELLS. WATER MAIN TO SEPTIC TANK SEEPAGE PIT DRAIN FIELD p /� SEPTIC TANK, � �, SEEPAGE PIT le"2�. DRAIN FIELD TO RIVER, LAKE, STREAM. il` I( ✓ I (' S c %>? U AREA SIZE TYPE %q t }/ DIAGRAM OF SYSTEM CAST IRON INTO AND OUT OF SEPTIC TANK AND INTO CRIB CROSSING GAP OF EXCAVATION 5 FEET INTO UNDISTURBED SOIL. 4 INCH DIAMETER CAST IRON SIPHON PIPES ON SEPTIC TANK AND SEEPAGE PIT FITTED WITH AIRTIGHT REMOVABLE CAPS. GRAVEL BACKFILL CONFORM TO BOROUGH REGULATIONS REGARDING INSTALLATION. l G.A.A.B. OR LICENSED DESIGNER 1 CERTIFY THAT I AMFAMILIAR WITH THE REQUIREMENTS OF GREATER ANJGEEA BOROUGH ORDINANCE NO. 28.68 AND THAT THE ABOVE DESCRIBED SYSTEM IS IN ACCORDANCE WITH SAID CODE. �il/i/ltd/,mai Performed for Legal Descript This form repo Depth Feet Y _ _ RM 3- 12 - lXIM 14 - GREATER ANCNORAGL ARLA BOROb,.i Department of Environmental Quality 3330 "C" Street Anchorage, Alaska 99503 SOILS I,OU - PEROI,ATION TEST Sod s Date Per forrit, d ;/21) rcoiation Was ground water encountered? `1c> If yes, at what depth? Reading Date Gross Time Net Time Depth to Water Net Drop s II Was ground water encountered? `1c> If yes, at what depth? Reading Date Gross Time Net Time Depth to Water Net Drop Percolation rate minute. ,Proposed installation: Seepage Pit__ __�._ Drain Field Depth of Inlet �__. Depth to bottom of pit or trench COMMENTS: Performed [3y: Linc! 1._ Certified__ - e A0C/104AGd 4— 4 di"i s GREATER ANCHORAGE AREA BOROUGH Department of Environmental Quality °nPFG „„G,4y 3330 "C” Street, Anchorage, Alaska 99503 274-4561 Date Received February 28, 1977 Time of Inspection 3;,3L) P)-Yj, tL a Date of Inspection-lDn-i� OlLeurS. REQUEST FOR APPROVAL OF TJ1� INDIVIDUAL SEWER & WATER FACILITIES FOR Conv. 1. Approval requested by: Peoples Bank and Trust Company Mailing Address: Pouch 7007 99510 Phone: 279-7511 x 246 2. Property Owner: Roy D. Inman Phone: Mailing Address: % Mr. Lamar R./Nancy J. Steen 272-4441 x 78 3. Legal Description: Lot 1 Homan Acres Subdivision 4. Location: NHN East 112th Avenue 5. Type of facility to be inspected Single Family No. of bedrooms 2 6. Well Data: A. Type Individual B. Depth C. Construction D. Bacterial Analysis 7. Sewage Disposal System: On—site system A. Installed B. Installer C. Septic Tank: 1. Size 2. Manufacturer D. Seepage Pit: 1. Absorption Area 2. Material E. Disposal Field: Total length of lines 8. Distances: A. Well to: Septic tank , Absorption area Sewer Lines , Nearest lot line Other contamination B. Foundation to septic tank , Absorption area C. Absorption area to nearest lot line EO -034 (1/74) Pann 1 of twn nanac MUNICIPALITY OF ANCHORAGE ® �f DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION 2510 East Tudor Road, Anchorage, Alaska 99504 276-2221 REQUEST FOR APPROVAL OF INDIVIDUAL SEWER and WATER FACILITIES 1. Type of Inspection: CMRO VA FHA CONV X 2. Property Owner: ROY D. INMAN Mailing Address: UNKNOWN Day Phone: UNKNOWN 3. Name of Buyer: LAMAR R. & NANCY J. STEEN Mailing Address: NSA Day Phone: 272-4441 EX 78 4. Name of Lending Institution: PEOPLES BANK & TRUST COMPANY Mailing Address: Pouch 7007 Phone: 279-7511 ex. 246 Anchorage, Aias a 5. Name of Realtor or Agent: NONE Mailing Address: Phone: 6. Legal Description:—Lot 1, HOMAN ACRES Location: NHN E. 112th Avenue, Anchorage, Alaska 99507 7. Type of Facility to be Inspected: SINGLE FAMILY No. Bdrms. 2 8. Water Supply Type of Supply: Public Utility Individual X If Individual, number of dwellings presently served ONE If Individual, depth of well UNKNOWN 9. Sewage Disposal System Type of System: Public Utility Individual (on-site) X If Individual, date of installation UNKNOWN 72-00313/76) TO SET UP AN APPOINTMENT FOR INSPECTION, CALL MR. STEEN AT 272-4441 Ex. 78. MUNICIPALITY OF ANCHORgt•,E ENVIRONMEOF HEALTH NTAL PROTECTION FE8 2 8 1977 RECEIVED I 'Page 2 of two pages - Rec._st for Approval of Individual S ^ar & Water Facilities Legal Description Lot 1 Homan Acres Subdivision Comments 1\k Approved Disapproved ( Date 3L S— 77 Approval,Valid for one year from date signed Greater Anchorage Area Borough, Department of Environmental Quality DIAGRAM OF SYSTEM I certify that the information contained in this request for approval to be a true and accurate representation of the subject sewer and water facilities and these facilities are operating satisfactorily. SIGNED Date EQ -034 (1/74) Mare llr 1977 Peoples Hanle and Truant Company Pouch 7-007 Anchorage, Alaska 99510 Subject. Lot 1 Homan Acres Subdivision Your request for approval on the subject property for sewer and water facilities serving this property can not be approved at this time. Enclosed is a set of instructions you will need to follow* if the percolation test should happen to fail, You will nedd to enaa&rge your sewer seepage area. if necessary, mon*es may be escrowed to complete the upgrade by June 3or 1977. if there are any further questions, please contact this office at 279-2511# extension 224 or 224. sincerely, Robert C. Pratt► R.S. sanitarian RCPJIjh MUNICIPALITY OF ANCHORAGE Development Services Department Phone: (907)343-7904 On -Site Water & Wastewater Section Fax: (907)343-7997 Parcel ID 015 -271-52 Certificate of On -Site Systems Approval OSC251136 Expiration Date: 9/23/2025 Legal description HOMAN ACRES LT 1 Site address 3101 E 112TH AVE Current property owner(s) BONNER LAURA J LIVING TRUST X The On-site system(s) is/are approved for 3 bedrooms Conditional approval for bedrooms, with the following stipulations: Comments or conditions.- 0 onditions: 0 Original Certificate Date 4/25/2025 ThWt rfificate of On -Site Systems Approval (COSA) is intended to demonstrate the subject sys dm(s) is/are in substantial compliance with municipal code. The Municipality of Anchorage, pivelopment Service Department (DSD) issues COSAs based upon representations provided by an independent professional engineer. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's submittal. ATTACHMENTS: COSA Checklist X Well Flow Advisory Absorption Field Advisory Nitrate Advisory Tank Age Advisory Arsenic Advisory Other Certificate of On -Site Systems Approval Application 1. GENERAL INFORMATION Parcel 1. D. 015-271-52 Complete legal description HOMAN ACRES LOT 1 Location (site address) 3101 E 112T" AVENUE ANCHORAGE, ALASKA 99516 Current property owner(s) LAURA J BONNER Day phone 2. ON-SITE SYSTEMS SIZED FOR 3 BEDROOMS 3. TYPE OF WATER SUPPLY: Z Private Well ❑ Private Well serving 2 dwelling units ❑ Private Well serving 3+ dwelling units ❑ Community Well or Public ❑ Water Storage 4. TYPE OF WASTEWATER DISPOSAL: Z Private Septic ❑ Private Septic serving 2 dwelling units ❑ Holding Tank ❑ Community Septic or Public Sewer 5. SEPTIC TANK: ❑ Steel Z Plastic ❑ Concrete ❑ Fiberglass Age NEW - See advisory if steel older than 20 years 6. ABSORPTION FIELD: ❑ AWWTS ❑ Bed Z Deep Trench ❑ Wide Trench ❑ Seepage Pit Waiver request for: Expedited review requested: ❑ Distance: By applying for this entitlement, this property is subject to inspection by municipal On-site staff to verify the accuracy of the information provided. COSA Fee $_ VA6 Date of Payment COSA#SGZS d3 Waiver Fee $ Date of Payment Waiver # COSA Application.doc COSA Checklist.docx COSA Checklist Legal Description: HOMAN ACRES LOT 1 Parcel ID: 015-271-52 If more than 1 well and/or septic system on lot, provide separate checklist. Structure served by this system ____ A. WELL DATA Well log is filed with Onsite (or attached) Date drilled UNKNOWN Total depth UNK ft Cased to UNK ft Sanitary seal is functioning correctly Wires are properly protected Casing height (above ground) 18+ in. Date of flow test for COSA 9/23/24 Static water level at beginning of test 139 ft. Well production at time of test 4.7 gpm Water storage tank volume None gallons Well disinfected for coliform test? Yes No Coliform bacteria is Negative Nitrate mg/L Nitrate less than MRL (ND) Arsenic ug/L Arsenic less than MRL (ND) Collected by Date 9/23/2024 Comments Per MOA documents the well was drilled circa 1975 & recent testing w/ acoustic sounder indicated 146’+ well water depth. B. TANK DATA Measured operating fluid level in septic tank NEW Date of pumping NA – NEW SEPTIC TANK Required maintenance completed, if AWWTS Comments: C. LIFT STATION Required maintenance completed Age of lift station years Lift station material Comments: D. ABSORPTION FIELD DATA Which system tested (date installed) NEW SYSTEM ALL standpipes present per record drawing Total measured depth from grade 10.1 ft (max) Measured depth to pipe invert from grade 6.5 ft (min) N/A – pressurized field. Per record drawings, field is insulated. Monitor tubes (MT) go to bottom of effective. (ED) If not, state depth into effective Presoaked required if (Required if house vacant or field not used for more than 30 days prior to date of test) Gallons introduced gallons date Any rejuvenation treatment (past 12 months) N If yes, enter date Adequacy test date NEW SYSTEM Results Pass Fluid depth prior to test in Water added gal New fluid depth in Elapsed time min Final fluid depth in Absorption rate gpd FIELD STATUS – NEW SYSTEM Effective depth (per record drawings) 24 in (MOA 2’ ED) Effective depth used 0 in (Final Fluid Depth) Effective depth (ED) remaining 24 in Comments/Deficiencies: Approximate total measured depths from existing grade. Also, the surveyor missed the FCO next to the house. Please see the attached photo. COSA Checklist.docx E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well on lot) Septic Tank/Lift Station on Lot > 100’ Yes if No ft Neighboring Tank > 100’ Yes if No ft Absorption Field on Lot > 100’ Yes if No ft Neighboring Absorption Fields > 100’ Yes if No ft Community Sewer Main > 75’ Yes if No ft Community Sewer Manhole/Cleanout > 100’ Yes if No ft Private Sewer/Septic Line > 25’ Yes if No ft Holding Tank > 100’ Yes if No ft Animal Containment > 50’ Yes if No ft Manure/Animal Excreta Storage > 100’ Yes if No ft N/A – Served by Community Well (not on lot) or Public Water From Septic/Holding Tank and Absorption Field(s) on Lot to: (Please enter distances if less than required) Building Foundations > 10’ Yes if No ft Tank to Property Line > 5’ Yes if No ft Field to Property Line > 10’ Yes if No ft Water Main > 10’ Yes if No ft Water Service Line > 10’ Yes if No ft Surface Water > 100’ Yes if No ft Wells on Adjacent Lots: Private Wells > 100’ Yes if No ft Community Wells > 200’ Yes if No ft If tank or field is under driveway comment below F. ENGINEER’S COMMENTS G. CERTIFICATION & STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines, indicates that the on-site water supply and/or wastewater disposal system appears to comply with applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation, unless noted otherwise. Name of Firm FIRST WATER CONSULTING Phone 907-350-9566 Engineer’s Printed Name CURTIS HUFFMAN, PE Date 04/04/2025 Comments: This investigation was completed in compliance with MOA guidelines, regulations, and best industry practices / methods. The assessment of the condition of the well and septic applies only to the conditions as of the day tested. The flow and absorption rates may change due to subsurface conditions that may not be observed from the surface, changes in land use, local soil characteristics, groundwater levels that may fluctuate during the year, quality of construction (workmanship & materials), the water usage of the family being served by the system and maintenance. The operational life of all well and septic systems are subject to these various and dynamic characteristics and are outside the control of the evaluator of the well and septic system. Therefore, any or NO estimate of how long a system will function satisfactory for current or future occupants or guarantee that no unseen encroachments, deficiencies or discrepancies exist can be given by First Water Consulting & 04/04/25 LOT 5 �o ql r< C < _ rm r I m. �I m Cn DI m �I m zl C I C L UTILITY Q PILE oN W m W W I W O O I N 90000'00" W 150.00' LOT 1 49,950 sq. ft. IT; SEPTIC STANDPIPES f'1 LOT 2 '0 SEPTIC MANHOLE LOT SHED 67) SEE BUILDING ' 43.2' x� DETAIL SHEDOx I } 53.4' T ROADAND I I GRAVEL UTILITY I VV WELL o DRIVEWAY EASEMENT / N REBAR --x 0 N 90°00'00" E 150.00' Cl) 112TH AVENUE- - — k 61 41 N' 1 -STORY FRAME % HOUSE N /36 6' k CNbMNFY l :. v� 0 4p 0' N 2 -STORY DECK FRAME HOUSE 4.01 GRAVEL DRIVEWAY �ccNCRETF. BUILDING DETAIL 1" = 30' IRON PIPE 0 M EASEMENTS OF RECORD, OTHER THAN THOSE SHOWN ON THE RECORDED SUBDIVISION PLAT (73-166) ARE NOT SHOWN HEREON. THIS DOCUMENT DOES NOT CONSTITUTE A BOUNDARY SURVEYAND IS SUBJECT TO ANY INACCURACIES THATA SUBSEQUENT BOUNDARY SURVEY MAY DISCLOSE. UNDER NO CIRCUMSTANCES SHOULD ANY OF THE DATA HEREON BE USED FOR CONSTRUCTION OF FENCES, IMPROVEMENTS, OR FOR ii O O N 00 W W W O O REBAR W/CAP IV 0 25' 50' AS -BUILT I HEREBY CERTIFY THAT I HAVE SURVEYED THE FOLLOWING DESCRIBED PROPERTY: LOT 1, HOMAN ACRES SUBDIVISION ANCHORAGE RECORDING DISTRICT, ALASKAAND THAT THE IMPROVEMENTSAS DEPICTED HEREON EXISTAS SHOWN IN RELATION TO THE PROPERTY LINES. DATED THIS 4th DAY OF MARCH 2025, AT ANCHORAGE, ALASKA. ESTABLISHING PROPERTY BOUNDARIES. FIXED HEIGHT LLC HEIGHT, C.O.A. 122554 Land Surveying Services WWW.FIXEDHEIGHT.COM JOB # 242336 I NO CORNERS SET THIS DATE I SCALE 1" = 50' 1 600 W 41st. Ave, Ste. C, Anchorage, AK 99503 907.290.8949