Loading...
HomeMy WebLinkAboutHUFFMAN #1 Block 1 Lot 10u Pyr 5/D L IQ bl ANCHORAGE AREA BOI( GH Department of Quality Environment 3500 Tudor Road Anchorage, Alaska 99507 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM SEPTIC TANK: DISTANCE FROM WELL ',~'~) INSIDE LENGTH MA N U FAC TU R E R '?#-/)?~'k $ g/) (~ ~ MATE RIAL NUMBER OF COMPARTMENTS, INSIDE WIDTH LIQUI'D DEPTH LIQUI'D CAPACITY/O/Df GALLONS. TILE DRAIN FIELD: -/--/~'~/~ ~ DISTANCE FROM WELL /~0 ~ FOUNDATION NEAREST LOT LINE TOTAL LENGTH OF LINES /LOLO NUMBER OF LINES DISTANCE BETWEEN LINES TRENCH WIDTH-- IN. TOTAL EFFECTIVE ABSORPTION AREA ~(~::~ SQ. FT. LENGTH OF EACH LINE ~'~ '" / DEPTH OF FILTER DEPTH: TOP OF TILE TO FINISH GRADE ~'-<// MATERIAL BENEATH TILE ~ IN. ABOVE TILE .IN. WELL: TYPE /A/J)I J'"/J)UJ~-L~/')/~J~£Li~J) CONSTRUCTION BUILDING NEAREST FOUNDATION /~q ~ LOT LINE /O SEWER LINE CESSPOOL /~/~)?J'C~ OTHER SOURCES APPROVED DISAPPROVED REMARKS DEPTH t~-'~/' DISTANCE FROM: SEEPAGE SYSTEM DISTANCES: DIAGRAM OF SYSTEM INSTALLED BY: ¥~'~F<9/~yg~, /-/0/)~.~_ SEWER LINE DEPTH: ~- <''/ LOT SLOPE: REMARKS: ,~ '.. ,~" .. -."~' , f"~jC_,~ , ---'=' '. '.' /,"' ' GREAT[ER ANC;HORA(..',c-. .;-.,, %(.2 ,:,,~,.,,.,',-,.,~','r oF ',-N'.',RO,,,,EN',','L O'..",'""¥ "E,M'T NO. · ' · ., 3500 TUDOR ROAD POUCH 6-650 SEWAGE DISPOSAL SYSTEM -- APPLICATION AND PERMIT ,.ST,LLAT,O. OP: ,EPT'CTA"~ Z''''' ¢,~EEPAGEP'Tm' ~ -'DRA'NP'E''~.,C,. -~': .. TYP, AND S'ZE OP'AC'L'TY TO BE SERVE. ~-'" TO BE INSTALLED SOl, TEST RESU,TS NOTEt THIS PERMIT IS NOT VALID WITHOUT ~OIL TESl COMPLETION DATE ANTICIPATED pFI~MTT VAI TD BNF YFAR FINAL INSPECTION~ 24 HOUR NOTICE: REQUIRED. BACKFILLING ~)F ANY SYSTEM WITHOUT FINAL INSPECTION BY HEALTH DEPARTMENT AUTHORI~ WILL BE SUBJECT TO PROSECUTION. SEPTIC TANK SIZE /~'~"~ ~ ~ TYPES[~O] O~ ~on~R~eSEEPAG[~ AREA.SIZE ~~-- TYPE -- MINIMUM DISTANCES, REQUIREMENTS . / I ~"' D~AGRAM OF S~TEM ~OUNDA~ON TO SgPT~O TANK ,] ~, ¢i* / * . * ~ .... '1 _..../ ~ ~....,.., ............... --" WELL TO SEPTIC TANK ' ' . . SEEPAGE PiT / ~ '"' -. / CAS1 ,0~ I"':' '¢'E: %. ~. SEPTIC TANK, 2~ ~e SEEPAGE PIT &vv zv*, DRAIN F~ELD ¢V *~- undcr drive~ay, TABLE) TO RIVER, LAKE, STREAM.- ---- CAST IRON INTO AND OUT DP SEPTIC TANK AND INTO CRIB CROSSING GAP OF EXCAVATION ~ PEET INTO UNDISTURBED SOIL. 4 INCH DIAMETER CAST IRON SIPHON PIPES ON SEPTIC TANK AND SEEPAGE PIT FITTED WITH AIRTIGHT REMOVABLE CAPS. GRAVEL BACKFILL CONFORM TO BOROUGH REGULATIONS REGARDING INSTALLATION. HEALTH AUTHORITY OR I CERTIFY THAT I AM FAMILIAR WITH THE REQUIREMENTS OF (~REATER ANCHORAGE ~REA BOROUGH ORDINANCE NO. ~8-~8 AND THAT THE ABOVE DESCRIBED SYSTEM IS IN ACCORDANCE WITH SAID CODE. ,. .~ . DEPA~ ENT oF ENViRoNMENTAL QUALi~'~ CASE .~ .~,~ 3500 TUDOR ROAD : ~ · ANCHORAGE; ALASKA 99502 Performed For Utopia Home Builders Date Performed ..... 9/15/72 Legal DesCription: LOtlO:'BloCk l":SUbdiVigiOn H~ffman NO,.1 This Form Reports Soils~g : X P'ePcOla'tion Te~t Depth m F~e~ Sol,! Characteristics Brown Sandy Silty Gravel (G~) Gray Sand Silt Mix (~L) Gray Sandy Gravel and Gravelly Sand (GW) & (SW) ~ Gray Sand - Silt ~ix Was Ground Water Encountered? No If Yes, At What DePth? ....... Reading Date Gross Time Net Time Depth to H20 Net Oro~ ate Minute Proposed Installation: Seepage Pit Drain Field x Depth Of Inlet Depth To Bottom Of Pit ~ Trench" COMMENTS: 100 sQ. ft. Of drainage .area is required.~er bedroom in ~ t~ ~ravel ~nd sand stratum. Test Performed By. Ccr!is!c Data Certified By: w~+~n~ Testing Svs. Inci Date: