HomeMy WebLinkAboutLot 06 - 086,2.
GRE _R ANCHORAGE AREA BOF $H
O Department of Environmental Quality
3330 C Street
Anchorage, Alaska 99503
SEPTIC TANK:
DISTANCE
FROM WELL
INSIDE LENGTH
MANUFACTURER .2~' (~' MATERIAL
INSIDEWlDTH LIQUID DEPTH__
COMPARTMENTS
.LIQUID CAPACITY /~'~',~) GALLONS.
SEEPAGE PIT:
NUMBER OF PITS / . DIAMETER OR WIDTH
LINING MATERIAL ~ ~-~ CRIB SIZE: DIAMETER
Y
BUILDING FOUNDATION__ NEAREST LOT LINE '-~L":~'0
ADDITIONAL ABSORPTION
LENGTH DEPTH
DEPTH DISTANCE FROM: WELL
TOTAL EFFECTIVE
ABSORPTION AREA (WALL AREA)
SQ. FT.
WELL:
FOUNDATION
CESSPOOL
CONSTRUCTION
NEAREST
LOT LINE
OTHER SOURCES
SEWER LINE
APPROVED DISAPPROVED REMARKS
DEPTH DISTANCE FROM:
SEPTIC SEEPAGE
TANK __ SYSTEM
DISTANCES:
INSTALLED BY: ~ ~
PIPE MATERIAL:
LOT SLOPE:
REMARKS:
DIAGRAM OF SYSTEM
DATE ~- (~'~ r'r/ APPROVED
G.A.A.B.
SEWAGE
GreaTer ANCHOrAgE ArEa Borough
DEPARTMENT OF ENVIRONMENTAL QUALITY / PERMIT NO.
3330 "C" STREETTELEPHONE ANCHORAGE,274.4~61ALASKA 99503 ,~ 7~///~ ~ ~(.~
DISPOSAL SYSTEM m APPLICATION AND PERMIT
£
INSTALLATION OF: SEPTIC TANK SEEPAGE Pit , DRAIN FIELD . ,, OTHER
SOIL TEST RESULTS ~~/~: NOTE~ THIS PERMIT IS NOT VALID WITHOUT SOIL
COMPLETION DATE ANTICIPATED
FINAL INSPECTION: 24 HOUR NOTICE REQUIRED. BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION BY THE
DEPARTMENT OF ENVIRONMENTAL QUALITY AUTHORITY WILL BE SUBJECT TO PROSECUTION.
MINIMUM DISTANCES, REQUIREMENTS
FOUNDATION TO SEPTIC TANK
fOUNDATION TO SEEPAGE PIT ~ DRAIN FIELD
SEPTIC TANK TO SEEPAGE PIT WALL
SEPTIC TANK ., SEEPAGE Pit
TO NEAREST LOT LINE.
WELL TO SEPTIC TANK
DRAIN FIELD
WATER MAIN TO SEPTIC TANK J -~J ' DRAIN FIELD
sePTIC TANKj~/~_~] ~ , SEEPAGE Pit TO RIVER, LAKE. STREAM.
CAST IRON INTO AND OUT OF SEPTIC TANK AND INTO CRIB CROSSING GaP OF
EXCAVATION 5 FEET into UNDISTURBED SOIL.
4 INCH DIAMETER CAST IRON S1PHON PIPES ON SEPTIC TANK AND SEEPAGE PIT
FITTED WITH Ai RTIGHT REMOVABLE CAPS,
SEEPAGE AREA SIZE ,/'~'~'~/~'~'/~'~' TYPE
/~/~C DIAGRAM OF SYSTEM
_, DRAIN FIELD
ALSO CONSIDER AREA WELLS.
SEEPAGE PIT ,/~J
GRAVEL BACKFILL
CONFORM TO BOROUGH REGULATIONS REGARDING INSTALLATION.
OR
I CERTIFY THAT I AM FAMILIAR WITH THE REQUIREMENTS OF GREATER ANCHORAGE AREA BOROUGH ORDINANCE NO, 28-68 AND THAT THE ABOVE
DESCRIBED SYSTEM IS IN ACCORDANCE WITH SAID CODE.
· TESTING · EXPLORATION · CHEMICAL · MATERIALS · INSPECTION
/ ~ 279-2581
t940 POST ROAD ~
ANCHORAGE. ALASKA
995o, July 8, ~974
W.O. #16752
Greater Anchorage Area Borough
Department of Environmental Quality
3330 "C" Street
Anchorage, Alaska 99501
ATTENTION: Mr. Roll Strickland
GRE,MkR ANCHORAGE
SUBJECT: Lots 6 & 7, Block 2, Huffman Subdivision
Gent 1 emen:
On June 28, 1974, Peter Herstek of our staff, revisited the site to check
for the free water level. A 3 foot deep, 5 inch diameter hole had been dug
in the bottom of the existing pit, previously logged in our June 17, 1974,
report, Mr. Herstek then extended this test hole with an Oakfield sampler
to a depth of 4.0' below the bottom of the existing pit, which when re-
measurgd was 15.0' deep. No evidence of the free water level was observed
to a depth of 19.0' below natural ground.
We trust this is sufficient information for your needs.
Yours very truly,
?TESTLAB .
John M. Lambe
JML/vms
MEMBER
279-2581
June 17, 1974
W.O 16752
United Construction
P.O. Box 4-1518
Anchorage, Alaska
Subject:
Seepage Pit Analysis
Lots 6 & 7, Block 2, Huffman Subd.
Genllemen:
Transmitied herein are the results of the subsurface investigation performed
on the above property. ExploratiorJ consisted of logging the existing excavation
for the proposed seepage pit. Grab samples were taken of each major soil type.
The soils were visually classified in the field in accordance with sheets 1 through
3 following the text. This field classification m-as verified by visual rewew of
samples based on the same criteria, in the laboratory. The test hole was logged
by Peter Herstek, technician of our staff. The test hole was logged as follows:
Depth in Feet
FROM TO
SOIL DESCRIPTION
0.0 1.5
F-.4, Brown Organic Sandy.Silt, Damp, Low to Medium
Density, NP~ ML/OL
1.5 4.0
NFS, Brown Sandy Gravel, Damp, ~Zledium Densily,
1 1/2"-, GP
4.0 14.0
F-2, Tan Sil~_y_. Sand with Random Gravel, Damp, Medium
High Density, SM
Bottom of 'rest Hole: 14.0 ft.
Frost Line: Not Recorded
Free Water Leveh None Observed
MEMBER
~age 2 June t7, ]974
United Construction
Sample Depth
1.0-1.5
1.5-4.0
7.0
13.0
Remarks:
Type of Sample
Grab
Grab
Grab
Grab
Test Hole located per attached sketch
Elevation: Existing ground
Date of Exploration: June 17, 1974
The seepage area required per bedroom by soil type (per the Greater Anchorage
Area Borough) is as follows:
Soil Type (Unified Classification
Seepage Area Required
ML
SM
SP
SW
GM
GW
275 ft2/bedroom
250 ft2/bedroom
150 ft2/bedroom
125 ft2/bedroom
225 ft2/bedroom
85 ft2/bedroom
Soils requiring greater than 250 ft2/bedroom are not allowed in seepage pit area
calculations (per the Greater Anchorage Area Borough).
The seepage area required at depth can be expressed as follows:
Unified Soils
Depth Classification
Seepage Area Required
0 - 1.5 1ML Not Allowable
1.5-4.0 GP 85
4.0-14.0 SM 250
United Construction
Page 3
June 17, 1974
Enclosed are some excerpts from State and Borough ordinances which may be
of value to you. For further restrictions, particularly with reference to
location of the set, page pit, we call your attention to the Greater Anchorage
Area Borough Ordinance 28-68.
Please call if we can be of further service.
Very truly yours,
ALASKA TESTLAB
John M. Lambe
JML: mm
Enelgsure
Approved.~~ ~~
H.R. Lee, P.E.
ALASKA
TESTLAB
CONSULTATION ~ TESTING ~ EXPLORATION 0 CHEMICAL
ATER,ALS NSPECT,O
SOIL CLASSIFICATION CHART
30% GRAVEL
x CLAYEY
CLAY EY
\ \~
OR
SI LTY
SI LTY' x \
SAND \
\ ~DY \G :AVE L
' \\SA
GRAVE LLY ND
0 I0 20 50 40 50 60 70 80 90 I00
,GRAVEl (+~IOSCREEN) i % BY WEIGHT
NONFROST SUSCEPTIBLE SOILS ARE INORGANIC SOILS CONTAINING LESS THAN 3% FINER THAN
GROUPS OF FROST-SUSCEPTIBLE SOILS:
FI GRAVELLY SOILS CONTAINING BETWEEN 5 AND 20% FINER THAN O,02mm.
F3 o.
F4 a.
b.
C.
d.
SANDY SOILS CONTAINING BETWEEN 3 AND 15% FINER THAN 0.02 mm. '~
GRAVELLY SOILS CONTAINING MORE THAN 20% FINER THAN O,02m~. AND SANDY SOILS
(EXCEPT FINE SILTY, SANDS) CONTAINING MORE THAN 15°/o FINER THAN O.02mm.
CLAYS WITH PLASTICITY INDEXES OF MORE THAN 12, EXCEPT VARVED CLAYS.
ALL SILTS INCLUDING SANDY SILTS.
FIN___~E SILTY SANDS CONTAINING MORE THAN 15% FINER THAN O.02mm.
LEAN CLAYS WITH PLASTICITY INDEXES OF LESS THAN 12.
VARVED CLAYS.
g
.... o .~.~ _~ ...... ~ ~
ALASKA
TESTLA8
CONSULTATION C~ TESTING @ EXPLORATION r~ CHEMICAL O MATERIALS 0 INSF'ECTION
The soil descriptions shown on the logs are the best estimate of the soil
characteristics a~: the time of field examination. Such examinations do not
achieve the precision of laboratory tests for the various properties.
1. The relative type of soil and the frost classification are shown on
the sheet, "Soil Classification Chart."
2. Other criteria:
Boulder - greater than 8"
Cobble - approximately 3" to 8"
Blow Count - blows/6" of 140-1b. weight falling 30"; 2" split spoon.
(The standard penetration is blows/12".)
Density - estimated by the rate of drilling type of soil, blow
count, and moisture range.
PL - Plastic Limit, moisture content being approximated as
above (+) or below (-) plastic limit (PL) or liquid
limit (I~) as appropriate.
~ - Liquid Limit, see PL
Dilatency - is the ability of water to m~grate to the surface upon
vibration or jolting of a sample, an aid in determining
whether a soil is predominatety a clay or silt.
Wgll graded - uniformity coefficient greater than 7
Poorly graded - uniformity coefficient tess than 7
(Uniform particles, gap graded)
Organic Content - estimated by volume, not particularly precise.
Clayey Soils - a field method now being used as an aid to identifi-
cation of these soils as a combination ball drop, and
rolled thread test in which a 2" diameter ball of the
Sand-Silt-Clay fraction is dropped 2' until a 1" thick
pat develops. The diameter of a thread at crumbling
rolled from the resultant pat determines whether clay
or silt predominates.
Dry Strength - a small s~p!e of the soil is fo~ned into a cube and
air dried, and crushed between the fingers. High dry
strength indicates clays and low silts.
Water Table the apparent water table at the time of observation.
Often the actual water table may be higher unless the
hole is allowed to remain open or is converted to an
observation well.
Capillary Fringe change from moist to very damp, or satura~ed soil,
usually indicates that water table is close.
- Fibrous material of macroscopic and microscopic fragments
of decayed vegetable matter; very compressible, unsuit-
able for foundation or embankment. Color light brown
to black.
Ao - The upper layer, surface soil or topsoil, containing
humus and/or organic debris, not satisfactor~ for
foundations.
/'Peat
I. Approval requested by:
Mailing Address:
2. Property Owner:
Mailing Address:
3. Legal Description:
4. Location:
GREATER ANCHORAGE AREA BOROUGH
Department of Environmental Quality
3330 "C" Street, Anchorage, Alaska 99503 274-4561
Date Received July 28, 1976
Time of Inspection
Date of Inspection
REQUEST FOR APPROVAL OF Pratt
INDIVIDUAL SEWER & WATER FACILITIES
FOR
Conv.
National Bank of Alaska
9:30 a.m.
8- 2- 76 Monday
Post Office Box 600
Henry J. & Daisy M. Korpi
Phone:
Phone: 279-3850
Box 4-1518
Lots 6, 7 and 8 Block 2 Huffman Subdivision
See map
5. Type of facility to be inspected
6. Well Data: Individual
A. Type
Single Family No. of bedrooms 3
C. Construction
7. Sewage Disposal System:
A. Installed ~/~])~
C. Septic Tank: 1. Size
D. Seepage Pit: 1. Absorption Area
E. Disposal Field: Totals. length of lines
8. Distances:
B. Depth
D. Bacterial Analysis
On-site system
B. Installer
2. Manufacturer
2. Material
A. Well to: Septic tank t~_~' , Absorption area /~(~'
Nearest lot line , Other contamination
B. Foundation to septic tank , Absorption area
C. Absorption area to nearest lot line
., Sewer Lines
E0-034 (1/74) Paam 1 nf twn naap~
1. Type of Inspection:
2. Property Owner:
Mailing Address:
3. Name of Buyer:
MUNICIPALITY OF ANCHORAGE
DEPARTIVIENT OF ENVIRONNIENTAL QUALITY
3330 "C',' Street, Anchorage, Alaska 99503 - 274-4561
REQUEST FOR APPROVAL OF
INDIVIDUAL SEWER and WATER FACILITIES
CM RO VA F HA
' ~/ b". ~ " '/ -' "" :/'
CONV ~
Mailing Address:
4. Name of Lending Institution:
Mailing Address:
5. Name of Realtor or Agent:
Mailing Address:
Day Phone
Phone
Phone
7. Type of Facility to be inspected:
8. Water Supply
Type of Supply:
Public Utility
If Individual, number of dwellings presently served
If Individual, depth of well
Sewage Disposal System
Type of System: Public Utility
If Individual, date of installation
Individual
Individual (on-site)
EQ-037 (1/74)
178
HUFFM~N
Ro.,~P
172
177 -<(~)~ 179
184
Rabbit Creek Area Reference [V1ap-P13
Page 2 of two pages - Req t for Approval of Individual S r & Water Facilities
.~Leg~l Description Lot 6, 7 and 8 Block 2 Huffman Subdivision #1
Comments
Di sa pproved Date
Approval Valid for one year from date signed
Greater Anchorage Area Borough, Department of Environmental Quality
DIAGRAM OF SYSTEM
certify that the information contained in this request for approval to be a true and
accurate representation of the subject sewer and water facilities and these facilities
are operating satisfactorily.
SIGNED
Date
EQ-034 (1/74)
06o]~20f~) R~v. ~973
DATE
ALAS ~)EPARTMENT OF HEALTH ~AND SOCIAL sE ES
DIVISION OF PUBLIC HEALTH
INDIVIDUAL AND SEMI*PUBLIC
BACTERIOLOGICAL WATER ANALYSIS
Lab No.
OFFICE
NDIVIDUAL []
NAME
ADDRESS
SEMI-PUBLIC [] CHLORINE RESIDUAL PPM
REPORT RESULTS TO
CITY
ADDRESS
OF SOURCE
ZIP CODE
COMPLETE THIS SECTION
ONLY ~F WATER IS Aw INDIVIDUAL SUPPLY
SAMPLE COLLECTED BY
DATE COLLECTED
Sample Collected From [] Kitchen Tap
~ Other (List)
Well- [] Dug [] Driven E Drilled
SOURCE: [] Spring [] Cistern [] Other
Dug Well or Cistern Construction:
Walls--[] Wood [] Concrete [] Metal
Top -- [] Wood [] Concrete [] Melal
LOCATION:
[] In Basement [] Basement Offset
[]In Yard [] Other
Building Sewer
DISTANCE TO: or Other Drainage PipP Feet.
Tile Seepage Cess-
Field Feet. Pit Feet. Pool
Other Possible
Sources of Contamination
MATERIAL: Building Sewer- [] Cast Iron [] Wood [] rile
[] Plastic Joint Materlal - Type
GENERAL: Does Water Become Muddy or Discolored?
When?
Diameter of Well
Well Casing
Material Diameter
Length of
Drop Pipe
Offset in
PUMP LOCATION: ~ In Well [] Basement
On Top
[] Of Well [] Other
PURPOSE OF EXAMINATION: Illness Suspected?
New Source of Supply? [] Yes
READ INSTRUCTIONS
ON
REVERSE SIDE
BEFORE
COLLECTING SAMPLE
[] Basement Tap
[] Tile Brick or
[] Open Top[] Concrete
[] Under House
TIME COLLECTED
[] Bathroo~ Tap
Septic
Tank Feet
__ Feet. Privy Fbet,
[] Fibre _-- Asbestos
Cement
[] Yes [] No
Depth Feet.
Depth
Water Depth
From Bottom Feet,
n Utility
[] In Basement [] Roam
SANITARIAN'S REMARKS
Reported by
This analysis indicates Coliform Organisms to be:
EMB AGAR
Lactose Broth, 24 hrs. 48 hrs. Gram's stain
Coliform Density Most probable No. per 100cc)
MF Results
Lactose Broth 10cc 10cc 10cc 10cc 10cc 1.0cc 1.0cc
24 Hours
48 Hours - ..... -
BrilJTant Green
24 Hours
48 Hours
Absent
Present
Analysis shows this Water SAMPLE to be:
[] Satisfactory
[] Unsatisfactory
[] Questionable
[] Sample too tong in transit; sample should not be over 48
hours old at examination to indicate Iel~able results. Please
send new sample.
[] Bottle broken in transit, please send new sample.
[] Yes [] No
[] No Repairs to System? [] Yes [] No Signature
o6-122o ~ BACTERIOLOGICAL WATER ANALYSIS RECORD
Re~ 1973
Date Received ':' Time Received _apn~m Lab. No,