Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
HUISINGH LT 1
. ' Municipality of Anchorage Page DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744 On-Site Wastewater Dis~:osal System and/or Well Inspection Report Permit Number: ~;;~X,V~' ~,-~) O ~O ~, PID Number: N~: ~OO~ ~ ~O~ Wastewater System: ~New D Upgrade Address: ~ O'HALk~, ~ ABSORPTION FIELD Phone: No. cf~Bedrooms: ~Deep Trench ~ Shallow Trench ~ Bed ~ Mound ~ Other. LEGAL DESCRI PTI ON Sol, Rating: , ~ GPD/Sq. Ft. Total Depth fr~m~ ~°riginal grade: Lot: Block; Subdivision: Deplh to pipe bottom from original grade: Gravel depth beneath pipe Township: [ Range: I Section: Fill added above original grade; Gravel length: I I ~ ~. ~ f~. I Number of fines: Distance between lines: WELL: D New ~ Upgrade Gravel width: ~ Ft. J ~ Ft, Classification (Private. A,B,C): Total Depth: Cased TO: Tolal absorption area: Pipe material: D~ ~lled~,t Driller: Date Drilled: Static Water Level: Installer: Yield:GPM~ Pump Set at: FI. Casing'~eighl Above Ground:FL TANK SEPARATION DISTANCES ~ Septic ~ Holding ~S.T.E.P. ,I To Septic Absorption Litt Holding Public/Private Manufacturer: Capacity in gallons: w~, m~~ ]~o/ ~/ ~ >~o ~"'e"'"':5~ S.~f.o~ ~ LIFT STATION Water Size in gallons: Manufacturer: Lot t Foundation ~ Curtain Pu~p Make & Model ~ ~lectrical inspections performed by: Drain ~' O~ o~ BENCH MARK Remarks: Location and Description: Inspections performed by: ~ Dates: lst;O/'/'¢ Department of He~ th and t~mai ~l~rvices approval Reviewed and approved by ~.{A ,~ I ~?~ Date: EgOE DRIVE UNDERGNDUN~ k/ELL £AD]US ACCESS EASEMENT /V/Om/JCOF' / i08, 7 INV, 99,7 ~N M/mo Pi 140 V, 94,73 ,9ocr o £ £ep ~ic i~50 GAL STEP i0 6A6E 1-i/4~ PVC 1/4' HOLESBi~' CALE z?ENCH MARK, WOODEN DECK ASSUMED ELEV, lO0, O0 TBBBEN SPURKLAND P,E, 203 W15th Ave Anchoroge Ak 99501 LOT i HUISIA/OH POLL Y ~OUSSELAI£E S300 O'MALLEY ROAD SEPTIC SYSTEM AS BOILT DATE, OCT, 1S~ i975 SHEET, 3/3 GRID: c°637 I I -~'~ ~-'.~' ............ ~.3JSY~ ~Ti'-~ : FRONT PD~CH :, ELEF. SPURKLAND P.E. II 203 W 15TH. AVENUE ANCH. AK. 99501 LOT I HUISINGH S/D $$00 O'MALLEY NOAD OEORGE AND POLLY BOUSSELM£E DATE: 'OC~ 1,5, 1995 SHEET: 2/3 GRID: 2837 Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 COMMENTS DATE PERFORMED: Township, Range, Section: WAS GROUND WATER ENCOUNTERED? S IF YES, AT WHAT ~) DEPTH? p E Depth to Water A(ter Monitoring? Date:. SLOPE SITE PLAN Gross Net Depth to Net Reading Date Time Time Water Drop ~ ~ ~ ~'O ~ ~ ~ [.~...~PERCOLATION RATE __ (mmutes/mc~. PERC HOLE DIAMETER ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: ?,,~ ~ 72-008 ~Rev. 4/85~ RECEIVED Mu,lio,pality ol Anohoragt Ne~lth & Numan 8ervioeI MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND HUMAN SERVICES P.O. BOX 196650, 825 "L" STREET, ROOM 502 ANCHORAGE, ALASKA 99519-6650 PAGE 1 OF ~ ON-SITE WASTEWATER DISPOSAL SYSTEM (UPGRADE) PERMIT PERMIT NUMBER:SW950306 DESIGN ENGINEER:TOBBEN SPURKLAND, P.E. OWNER NAME:BOUSSELAIRE GEORGE F JR & OWNER ADDRESS:5300 O'MALLEY RD. ANCHORAGE,ALASKA 99516 PARCEL ID:01552107 LEGAL DESCRIPTION: HUISINGH LT 1 LOT SIZE: 43086 (SQ. FT.) NUMBER OF BEDROOMS: 3 THIS PERMIT: 3 DATE ISSUED:10/03/95 EXPIRATION DATE: 10/03/96 THIS PERMIT IS FOR THE CONSTRUCTION OF: DISPOSAL FIELD /SEPTIC TANK SYSTEM ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH: 2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS 15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80). 3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY CALLING 343-4744 ( 24 HOURS ) (NOT REQUIRED FOR WELL ONLY PERMIT) 4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING WEATHER MUST BE EITHER: A. OPENED AND CLOSED ON THE SAME DAY B. COVERED, SEALED AND HEATED TO PREVENT FREEZING 5. THE FOLLOWING SPECIAL PROVISIONS. EXCAVATE AN ADDITIONAL TEST HOLE NEAR SOUTH END OF PROPOSED TRENCH (WITHIN 30 FT) TO A DEPTH OF 18 FEET AND INSTALL A GROUNDWATER MONITORING TUBE. THIS GROUNDWATER MONITORING TUBE IS TO REMAIN ON LOCATION THROUGH MAY 1996. SUBMIT SOILS LOG FOR REFERENCED TEST HOLE WITH ASBUILT DRAWINGS. RECEIVED BY: ~~ DATE: /0//~/?('' T.SPURKLAND P.E. 203 W. 15th. AVE. SUITE 203 ANCHORAGE, ALASKA 99501 (907) 279-3916 Fax (907)-276-6013 Municipality of Anchorage Division of Environmental Health Department of Health and Social Services 820 1 Street Anchorage, Alaska 99501 Att.: James Cross Subject: Lot 1 Huisingh S/D Gentlemen; On September 12, 19951 performed an adequacy test on the existing septic system on this lot. Based on my observation the system is capable of absorbing 360 gallons per 24 hours, which is not sufficient for a three bedroom house. The conclusion is that a new septic system must be installed. A previous design based on a 4~ bedroom residence and a soil absorption rate of. 6 gal~ Per sq. Ft. per day has been rejected by DHSS because a lot line waiver was required as well as a waiver to the existing system. DHSS suggested that a system could be installed in the south half of the lot without any requirement for waivers. I am hesitant to design a system at this location due to presence of ground water and a soiltype that may liquefy in the presence of water. The ground water level during breakup is also a concern. The residence has been converted to a three bedroom house. This fact, and using an absorption rate of .8 gal. Will reduce the required length of the trench to 32 feet. A trench of this length can be installed as shown without encroaching on the lot line(s), the well radius, and the driveway to lot 2. The old log crib is also outside of the proposed trench. The only variance requested is the separation to the existing trench. A separation of 10 feet can be maintained, but not the required 14 feet. Please consider this request favorably. Yours ToS?URKLAND 203 W 15th. Avenue, Suite 203 ANCHORAGE. ALASKA 99501 (907) 279-3916 Fax (907)-276-6013 SEPTIC SYSTEM DESIGN LOT 1 HUISINGH POLLY BOUSSELAIRE No Ground Water or Impervious Layer to 18 fi. Use Standard Trench Soil Rating. From test 7/21/95 15 min/in = .8 gal/sq.ft, day No. of Bedrooms 3 Required Area per Bedroom: 150/.8 = 187.5 sq.ft.. Total area required: 3 X 187.5 =562.5 sq. ft. Testhole Total Depth 18 Less 6 feet 12 Less 3 feet Cover 9 Rock Depth 9 Existing Tank is 5 feet below ground, replace with 1250 gal STEP Length of Trench 562.5 / 18 = 31.25 [FT.] SYSTEM CONFIGURATION STANDARD TRENCH TOTAL LENGTH 32 FT. TOTAL V~IDTH 2 FT. TOTAL DEPTH 12 FT. ROCK DEPTH 9 FT. COVER 3 FT. STEP TANK 1250 GAL. The installation of this septic system will not prevent wells from be installed on the adjacent lots. There are no developed or natural surface / sub surface drainage courses on this or the adjacent lots. The proposed septic system will not change the general slope of the area. Ponding and/or concentration of surface runoff will not result from this installation. pg.1 i i ! ! ~_X_J ~, ~CCeSS 8oseRen~ o[ #2 i I I I I =~0~\'..o.'' ~ "*~'~. Z5 0 ~S SO 75 ~00 lES 150 _ . 49th-gth ~%~ m REVISED; SEPI-, 15, 1995 IBEN SPURKLAND P.E. 203 W 15TH. AVENUE ANCH. AK. 99501 5500 O'WALL£Y ROAD DATE: NOV. 50, 1994 GEORGE AND POLLY BOUSSELAIRE SHEET: 2/J GRID: 2637 EDSE DRIVE UTILITIE~ EXIST. TANK NEVI i£55 GAL STEP OLD LOG CRIB REMOVE ~/ELL RADIUS M/F'o £i 140 ]01-1 9 £~ o£ £eptlc P, ocl~ I-1/4" PVC, 1/4" HOLES ~ i£' EXIS T, TRENCH PROPOSED 32 FT, TRENCH ACCESS EASEMENT 4' Topsoil 3' Cover ]04_+ SCALE I~om/~Jor Ex/sS, Ground / ~ S FT, COVER i£55 GAL STEP REVISED SEPT, ]S~ 1995 BENCH MARK, WOODEN DECK ASSUMED ELEV, 100,00 TDBBEN SPURKLANB P,E, 203 W15th Ave Anchorage Ak 99501 LZTT 1_ HU/SI/VGH POLLU BOUSSELAI£E 5300 O'MALLEY ROAD SEPTIC SYSTEM DESIGN DATE, AUSUST ~ ]995 SHEET: 3/3 GRID, 2637 Mortgagea's Name ar d Address Property Address FHA Case Numeur Data of [nsoeation I. I~pection of On-Sim Improvements Reveals; t. Cm'mtruOflon[~] wee, I~] was not bag,m pri~.r la the d~le ~, ~ORg.ge · in~urao~ approval shown on the eammitment, statement of appraised value or "Earn Start" letter. (Appflee to the initial report on new c~n=tructioh) 1 2,[~ a~dlder other than named in application. 12.'~ 3.~ Onabte to muko Jnspe~[ion. (Explain* 4.~ A~epted C~tr.ctlhh exhibits not available at site, 5.~ Individual Sewage disposal system: ~ Individual Wets supply system 13. '~ No noncompliance, ~ Cmrecllon essential aa explained below, ~ Submit Health Deportment letter or form HUD-S2573 7 ~' R~It~ ~aquired by form HUD-B2800, SB .0t acceptably completed. 8.~ Correoti~ essential a~ explained below: ~ a, W~l examine at next inapeation. = ~ ~ b. Do not conceal until ~ No nonqomplian¢~rved. of statements checked in Parts I ~ I11 Framing I~p~[tion FInM Inspection Aecm~table variations es deacribud below (Requosl for Change, form HUD-S2577. may be eubmittudl. Extensive noncompliance as exl~fained below {~e¢ IV.A helowL On-site improvements acceptably completed subject to receipt of cettifloetlo~ that mortgagea'a inspection reveals satisfactory completion of all items listed below. On-site improvements socaptabl¥ Gomplctud ex0opt items listed below, aomplefion of which is delayed by conditions beyond control of the builder Iaaa IV.~I belowL On.site imorovcmonts aeaaOtebly aompleted. Off-site imorovumonts; ~a. CorreotionlComplet~on essential as oxaluined below, ~ b, Completig~ assured by escrow agreemem or aurar.ina auihoritv. ~c. A~ogotablv uompleted. Number CettJfloet}on: } cattily that I have oerefully {nsDected this ProDerty on this data. { have no personal interOa[, present or prospective, in the p~eperty, spDlicant, ; or proceeds of the mortgage. To the beat o[ my ktlowledge I have repo~ all n~cor~pllanco, wo~k ~eqLliri~g correction, a~d unacceptable work. ID Number ; :'~atu,~ / ~ ............. Oat~ FDa Insoector ~ Appraiser ~ III, Specific Conditions Required by tho HUD-92800.BB, Not Requiring Field Inspection ~ am m;dified ~ Direct Endoraonlo*l Ua~derw~i~er by me. ~ ~lli,~f Architect ~ Deputy IV. To Mortgagee: When signed below, refer to the statement on the back corresponding to the designation chocked, ~ ({.{i V(sHatiolls from I '] k:} P~'emeture unrmrruction. ..... _[~...~i.?ct.or nf Ik,u~,ng Dcvelosmont $i.q~}utum of HUD Authorizud Aflunt Id Number E~J. ~.¢.ut, v ....... T.SPURKLAND P.E. 203 W. 15th. AVE. SUITE 203 ANCHORAGE, ALASKA 99501 (907) 279-3916 Fax (907)-276-6013 Municipality of Anchorage Division of Environmental Health Department of Health and Social Services 820 1 Street Anchorage, Alaska 99501 /vYJNIC, IPAU'Pt OF AI'4q.~ORA~E ENVIk'ON/VlEI~TAL SEP, VI~ DIVI$101~ REC,EiVED August 11, 1995 James P. Williams Subject: Lot 1, Huisingh S/d Septic System Design Gentlemen; We are requesting a permit to replace the existing septic system on this lot. The present system encroaches on the protective well radius, and the Highway Right of Way and is not of the correct physical size with regard to the soil rating. There are limited space available in the north half of the lot. The south half has sloping ground and ground water was observed at 14.5 feet on July 27, 1995. The soil in the south half of the lot is also substantially siltier than the soil in the north half. Three testholes were excavated as shown on the siteplan. We prefer to install a deep trench where shown, due to the better soil and absence of ground water. In order to install the system we request a lot line waiver to 0 feet. Prior to installing the system we will locate the lot line and the protective well radius. We propose to use a STEP tank in order to shorten the trench by utilizing the soil from 3 feet to 10 feet. We do not intend to pressurize the discharge line. The existing trench was found with less than 2.5 feet of effluent. The old log crib was dry. The log crib will be removed and the excavation backfilled to proper depth. The separation distance between the existing trench and the proposed trench will bed less than ten feet. Since only 2.5 feet of effluent was observed in the existing trench the present trench will not interfere with the operation of the proposed trench. ToS P LAND 203 W 15th. Avenue, Suite 203 ANCHORAGE, ALASKA 99501 (907) 279-3916 Fax (907)-276-6013 SEPTIC SYSTEM DESIGN, LOT 1 HUISINGH POLLY BOUSSELAIRE No Ground Water or Impervious Layer to 18 ft. Use Standard Trench Soil Rating. From test 7/21/95 15 rain/in = .Sgal/s\q.ft. day ~,,-'> Use .6 gal per sq.ft/day ~ No. of Bedrooms. 4 Required Area per Bedroom: 150/.6 = 250 sq.ft.. Total area required: 4 x 125 = 1000 sq. ft. Testhole Total Depth 18 Less 6 feet 12 Less 3 feet Cover 9 Rock Depth 9 MUN CIPALITY OF AI',tC, HORAG~ ENVIRON~.NI'AL SER¥1C~ DI~jlt~I AUG I 1 1995 ,ECEIVED igc7 tq#. Existing Tank is 5 feet below ground, replace with 1500 gal STEP Length of Trench1000 /18 = 55.5 [FT.] ~-- ~'~',j', ~ ~- SYSTEM CONFIGURATION STANDARD TRENCH TOTAL LENGTH 60 FT. TOTAL WIDTH 2 FT. TOTAL DEPTH 12 FT. ROCK DEPTH 9 FT. COVER 3 FT. STEP TANK 1500 GAL. The installation of this septic system will not prevent wells from be installed on the adjacent lots. There are no developed or natural surface / sub surface drainage courses on this or the adjacent lots. The proposed septic system will not change the general slope of the area. Ponding and/or concentration of surface runoff will not result from this installation. pg.1 Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST PERFORMED FOR:' LEGAL DESCRIPTION: ~O T / 1 2 3 4 5 6 7 8 9 10- 11 12 13- 14- 15- 16 17- 18- 19- 20- .... ,~,.~.. ~ DATE PERFORME~ Township, Range, Section: ;LOPE SITE PLAN WAS GROUND WATER ENCOUNTERED? S L IF YES. AT WHAT 0 DEPTH? p E Oepth to Water Alter Menitoring? Date: Gross Net Depth to Net Reading Date Time Time Water Drop /~, ~-/~ ~ ~ - PERCO.ATION RATE TEST RUN BETWEEN (m~nutes/mch)vPERC HO.E DIAMETER __ , FT AND qT~-, FT COMMENTS PE.FORMEO B~: ~- , ~- CERTI~ AOOORDANOE W,THA" $~^TEAND ~UN.O,P^L ~U,DE.,NES IN E.EC. O. THIS OATE. DATE: 72-008 [Rev. 4/85) Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST LEGAL DESCRIPTION: ~_..O T' '~ ] I 3- 7- 8 g tO ~t 14- 16- 17- 18- 20 DATE PERFOR~ Township, Range, Section: WAS GROUND WATER ENCOUNTERED? SLOPE SITE PLAN Gross Net Depth to Net Reading Date TimeTime Water Drop Y l l, I, 7/,~1{ ~ ~- i"..u_ s , ~ ~.k. ; ~ ~ / m~ ~ ~/& ~/& PERCOLATION RATE . , "7~-/ [minutes/ih~ch) PERC HOLE DIAMETER .__ TEST RUN BETWEEN __ FT AND FT COMMENTS i~ERFORMED BY: I THAl THIS TEST WAS PERF?~RMED I.N . ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: ~gl/~ ~/'~ r 72-008 (Rev. 4/85) PERFORMED FOR: LEGAL DESCRIPTION: t 2- 3- 5- 6- ML 7 8 9 10- 11 '13- 14- 16- 17- 18- 19- :20- Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST k re- OATE PERFORM' Township, Range, Section: SLOPE SITE PLAN . I WAS GROUND WATER O ENCOUNTERED? s IF YES, AT WHAT DEPTH? P E Monitoring? ' ;. Oate; ! Gross Net Depth to Net Reading Date Time Time Water Drop F; ~ I ~/.~.v/ p'.,,.- ~ ~,,~ ~Y~ ; ~ I ~ ~o ~/~ PERCOLATION RATE "~ {minutes/inch) PERC HOLE DIAMETER TEST RUN BETWEEN /0 ET AND /0 Y~,. FT COMMENTS ~ERFORMED BY: '' I I' CERTIFY THA~[ THiS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE, DATE: I u 72~ (Rev, 4/~) N O~k/ALL£Y ROAD French not £1e~d located 0 5O 100 150 200 LOT £ v LOT 3 LOT £ LOT / TOBBEN SPURKLAND P.E. II II 203 W 15TH AVENUE ANCH. AK, 99501 (907/ 279-:5916 LOT ! ttU/SINGH S/D 5500 O'MALL£Y ROAD GEORGE AND POLLY BOUSSELNRE II SEPTIC SYSTEM DESIGN ]ATE: JULY 50, SHEET: 1/3 GRID: 2637 U?ILITIES EXIS T, TANK NEW I_500 6AL STEP ~LJ2 LI~ CRI~ REMOVE -- ~.. IVELL RADIUS EXIS T, FRENCH PRDPDSEZ? 60 FT. TRENCH ACCESS EASEMENT / ? 104+_ ND SCALE 5 FT. COVER --I' ~6AL STEP BENCH MARK w'Z7D~?EN DECK ASSUMED ELEV, /E~ T£ENCH NE~ / 60 FTi LZ7AI~ I lO0 ,/ I ~,, '~ :.i / 1£ FT .BEEP . ~r~- ~.EXIS~ 7~ENCH A. / 9 FT SEPTIC ~DCK / I TOBBEN SPURKLAND P.E. II II 203 W 15TH. AVENUE ANCH. AK. 99501 LOT 1 HUI$INGH $$00 O'MALL£Y OEORGE AND POLLY BOUSSELAIRE SEPTIC SYSTEM DESIGN DATE: NOV, 50, 1994 SHEET: 2/3 GRID: 2637 Municipality of Anchorage Rick Mystrom, F3.O, Box 196650 Anchorage, Alaska 99519-6650 Mayor August 29, 1995 Mr. Tobben Spurkland, P.E. 203 W. 15th Ave., Suite 203 Anchorage, AK 99501 Re: Lot 1, Huisingh Subdivision. Dear Mr. Spurkland: Your request to locate a proposed wastewater disposal field adjacent to an existing trench and encroaching on an existing crib has been denied. The proposed design does not meet the separation distances required by AMC 15.65. The soils information submitted with your permit request shows that adequate soils conditions exist to install a system on this property in the vicinity of test hole #3. If you have any further questions or comments, please contact me at 343-4360. Sincerely, Program Manager On-Site Water ~uality MUNICIPALITY OF Al OEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION 825 L0 Street, Anchorage. Alaska 99501 264-4720 SOILS LOG - PERCOLATION TEST PERCOLATION TEST ;) FOR: .' - --.. _- i , , .~. =' _ LEGAL DESCRIPTION LOT -Oi HUISIN~H L LC~H ORgANIcc, DATE PERFORMED: '";%e~ ~ll/,1~~ %ILT' 7 8 9 14 15 16 17 18- ,L 20- SLOPE SITE PLAN WAS O.OUND WATER I",J o [ ENCOUNTERED? IF YES, ATWHAT DEPTH? Reading Date Gross Net Depth to Net Time Time Water Drop ~/,o/~ -o- _ o -- g ~ '- PERCOLATION RATE ~*/(~ (minutes/inch) TEST RUN BETWEEN /O FT AND ~tOt'"~ FT CERTIF ED BY: , 72-008 (6/79) ~ MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION ENVIRONMENTAL ENGINEERING DIVISION 825 L Street- Anchorage, Alaska 99501 Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT NAME LEGAL DESCRIPTION PHONE . .I E]NEW LOCATION /% , NO OF BEDROOMS . Well _ ~ ~/ I Absorption ar~ Dwelling ~ . PERMIT NO, Ov DISTANCE TO: I ¢o I I ~r~ns ~- Z Manufacturer x-~ .__ ¢,"- I Material~-[ ! I No. of compartment u~ Liq. capg.cit~..j.n.,_galJons ~ , '^""EM^DE Inside length Width Liquid depth I~ ~ I DISTANCE IWell Dwelling ] PERMIT NO,, ~u ~. zo I No. of. lin..es~ I Length of each lir~ ~ Total length of linP~ ~/ I Trench width~ f I Distance betw,e~en ~ ~ I Top of tile to finish grade *¢'/t Material beneath tile ~., ~Z:~' I Total effective aoso.i~c~n)~ea 4 I- I T2cl~ib '/ l~rib diameter ~ Crib depth T~;;~s~effective absorp.;Ce~a "~' I DISTANCE TO: ~~ '- ' [C_.[t~ ~z.~ ~ Depth Driller Distance to lot line PERMIT NO. ~ [ ~DisTANoETO: Building foundation Sewer line Septic tank . I Absorptionarea(s) OTHER PIPE MATERIALS .1e c'c- SOl L TEST RATING NSTA!~LER REMAR. KS APPROVED DATE LEGAL ~ .. ~ OE~RTMENT ~ )HEaLT~ ~ND ENyIRONNENT~Lh..r(OTECTION ~' ~. ,_~5 ~TREET, ANCHORAGE., AK. ~501 PERMIT NO. < 800~4 > 8PPLICBNT 8LVIN E, HUISINGH SR8 BOX i7198 ~44-0~74 LOCBTION MUST NOT U~E i-8 FOOT-NO PERC TYPE OF SOIL ~SSORPTION SYSTEM IS: TRENCH .,.~:V N~XINUM NUMBER OF BEDROOMS : 4 SOIL R~TIN6 (SD ]~./BR): ~25 THE REQUIRED SIZE OF THE SOIL ~BSORPTION 5VSTEH IS~ -~. ~ THE LEN T D mENS ON THE LENGTH FEZT> THE..TRENCH OR THE DEPTM OF ~ TRENCH OR PIT I~ THE DISTANCE B~TMEEN THE ~{JRF~C:E O~THE GRgUND RND THE BOTTOM OF THE EXCRVRTION (IN FEET>. ~ ~ THERE IS NO SET WIDTH FOR TRENCHES. ": THE ~RRVEL DEPTH IS THE ~INIMUM DEPTH OF GRRVEL BET~E¢~' YH~ OUTFR~L RND THE BOTTOM OF THE EXCRVRTION (IN FEET>. .> ~ RFQUIRF[) S~PTIC TRICK SIZE= 125~ PERMIT RPPLIC~NT HRS THE RESPONSIBILITY TO INFORM THIS':DEP~ENT DURIN6 THE INSTRLLRTION INSPEOTIONS OF RNY ~ELLS RDJ~CENT TO THIS P~'OPi~T~' RND THE NUMBER OF RESIDENCES THRT THE WELL WILL SERVE. ~ T&~O ( 2 :) I NSP~CT I ON~ RRE 'RE.~U I RED ------ ~ROKF~LLIN~ OF RN¥ SYSTEM ~ITHOUT FINal iNSPECTION RND ~PPRO~RL BV THIS DEPRRTNENT ~ILL ~E SUBJECT TO PROSECUTION .... MINIMUM DISTRNCE ~ET~EEN R WELL RND RNY ON-SITE SEWR6E DISPO~RL $V~TEM~ IS lB~ FEET FOR R PRIVRTE WELL OR 15~ TO ~ FEET FROM R PUblIC WELL UPON THE TYPE Of PUBLIC WELL. TO 8 COMMUNITY SEWER LINE>~S 75 FEET. Z-.-~X~..;,-;.; ~>~ ?"' .... ) ~c~" -. OTHER REQUZREMENTS MeV ePPGY SPEC:IFZCeTIONS eND CONSTRUCTZ- D. .aBeD . E:,L · : I 8M F8MILIRR WITH THE REeUIREMENTS F R 2: I WILL INSTRLL THE SYSTEM IN 8CCORDBNCE WITH THE CODES. -'-~ -. ~: I UNDERSTBND THBT THE ON-SITE SEWER SVSTEM MBY REQUIRE ENLBRGEMENT RESIDENCE IS REMODELED TO INCLUD~ MORE THBN ~BEDROOMS. RPPL~CRNT~RLV~N E. HLI~S~NGH ISSUED DR - V4. PER~IT NO. APPLICGNT ALVIN E. HUISINGH LOCATION MILE 2.5 OMALLEY RD LEGAL ~ TYPE OF SOIL ABSORPTION SYSTEM MAXIMUM NUMBER OF BEDROOMS = 4 OF ANCHORF~OE DEPARTMENT ~ HEALTH AND ENVIRONMENTAL~OTECTION "~= ' ANCHORGGE, AK. 9!..~01 . 8~, % .~ STREET., · 264-4720 SAR BOX 298 AR' LOT ~IZE ~44-0~74 SQUARE FEET FT/BR)= 85 THE REQUIRED SIZE OF THE SOIL ABSORPTION DEPTH= ? LE~-~OTH-~- ~4 THE LENGTH DIMENSION IS THi THE DEPTH OF A TRENCH OR PI GROUND AND THE BOTTOM OF THERE IS NO SET WIDTH FOR THE GROVEL DEPTH IS THE AND THE BOTTOM OF THE EXCRVGT IN FEET> ) I STANCE (IN FEI ES. DEPTH GROVEL ~N ( IN :T>. RED --~EF'T I C PERMIT APPLICANT HAS INSTALLATION INSPECTIONS NUMBER OF ESIDENCES THAT WELL T 0 <2) I BACKFILLING ANY SYSTEM DEPARTMENT LL BE SUBJECT TO ISEC IS L DEPTH= 5 THE TRENCH OR D INFIE D. FWEEN THE SURFG~ OF THE THE;, :~!bUTFALL P I PE z ZE== ITY TO INFORM THIS DEPARTMENT ADJACENiT TO THIS PROPERTY .L SEA ¢E!i~ ,.~ RRB REC~ aND MINIMUM BETWEEN A WELL 100 FEET PRIVATE WELL OR l UPON THE TYPE PUBLIC WELL. MINIMUM FROM A PRIVATE WE~L TO 8 PRIVATE TO A COMMUNITY SEWER ~INE IS ?~ FE~T. 0~HER REQUIREMEN$~ MA~ APPLY. SPEOIFICATIONS,~ND COf AVAILABLE TO INSURE PROPER INSTALLATION. P~R~N IT F:~PIRES I CERTIFY THAT i: I AM FAMILIAR WITH~THE FORTH BY THE MUNICIPALITY OF 2: I WILL INS~LL THE SYSTEM IN ~: I UNDERSTAND THAT THE'ON-SITE RESIDENCE IS .ICRNT ALVIN E. ON-SITE SEWAGE DI TO 200 FEET FROM A PUBLI( B.E,2: E 1'4~ER TS F ON-SITE THE NCLUDE SIGNED: .... HUISINGH ~ING THE 25 FEET R~ DIAGRAMS AND WEt THE V4. 0 PERFORMED FOR: LEGAL DESCRIPTIOI 5 6 7 8 9 l0 11 .12 13 14- ~15 - 16- 17- 18- 19- 20- COMMENTS Lo'+- © MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION Pouch 6-650, Anchorage, Alaska 99502 276-222t; SOILS LOG - PERCOLATION TEST / ~ SLOPE ~ ISOILS LOG [] PERCOLATION TEST SITE PLAN WAS GROUND WATER . ~ ~.?--4---4 -- IF YES, AT WHAT ~ ._~ ..... ~_,L L_L_,_,I ~ _...~ ..... [_,, Gross Net Depth to Net Reading Date Time Time Water Drop PERCOLATION RATE TEST RUN BETWEEN FT AND (minutes/inch) FT PERFORMED BY.'~--~~ ~ MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & HUMAN SERVICES Division of Environmental Services On-Site Services Section P.O, Box 196650 Anchorage, Alaska 99519-6650 343-4744 Parcel I.D. CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING GENERAL INFORMATION Complete legal description Location (site address or directions) Property owner Mailing address Lending agency Mailing address Agent Address Day phone Day phone Day phone Unless otherwise requested, HAA will be held for pickup. NUMBER OF BEDROOMS: '~ TYPE OF WATER SUPPLY: Individual well ~ Community well Public Water ZO NOTE: lng to the legality and status of system. If community well system, provide written confirmation from State ADEC attest- TYPE OF WASTEWATER DISPOSAL: / Individual on-site NOTE: Holding tank Community on-site Public sewer If community wastewater system, provide written confirmation from State ADEC attesting to the legality and status of system. 72-025 [Rev. 1/91) Front MOA #21 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health Authority Approval application shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on the date of this inspection. NameofFirm '~ ~Jo-~'l ~--~ttJv'~',-~-*-~-~, Phone '~-'l-E}-'~ctl Address ~0 ~ t.~ /~/.-~ Engineer's signature ~ ~--~~ Date DHHS SIGNATURE Approved for -~ Disapproved. Conditional approval for bedrooms. bedrooms, with the following stipulations: Additional Comments Date The M'u0ici~ality of Ar~chorage Department of i-.~,ealth and Human Services (DHHS) issues Health Authority Approval Certificates based only upon the representations given in paragraph 5 above by an independent professional engineer registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes and thei~ lending institutions in order to satisfy certain federal and state requirements, Employees of DHHS do not conduct inspections Or analyze data before a certificate is issued, The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 72~)25 (Re~. 1/91) Back MOA #21 Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES Environmental Services Division 825"L" Street, Room 502 · Anchorage, Alaska 9'9501· (907) 343-4744 Health Authority Approval Checklist LegalDescription: Lo4- I: ~ t~,,~'~;~ ParcelI.D.: O I~'- A. WELL DATA Well type 7~ If A, B, or C, attach ~EC letter. ~ water ~stem number Log present (Y~) ~ Date completed / ~80 , Totaldepth > ~ Casedto 23g~ Casing height (above ground) Sanita~ seal (Y~) x/ Wires properlyprotected (Y~) FROM WELL LOO AT INSPEC~ON t Date of test ~ ~[ Static water level ~l ~ I Well production g.p.m. ~' ~ WA~R S~LE ~S~TS: Coliform ~ Nitrate ~ ~ O~er bacteria / Date of sample: I0/~, ] ~ r Collected by: ) ,' ~ B. SEPTIC/HOLDING TANK DATA Date installed t / 94 Tank size Fom~dation cleanout (Y/N) y ] ~ ~'O Number of Compartments Depression (Y/N) ~{ High water alarm (Y/N) Y Date of Pumping W/~__~_ Pumper C. ABSORPTION FIELD DATA IO'~-- I ~ Date installed / ~ ~ Length ~aQ,-I Width ---.--'- Soil rating (g.p.d./W or ft Podrm) · (5> System type ~ I Gravel thickness below pipe Total depth Effective absorption area Date of adequacy test Fluid depth in absorption field before test (in.); J~///ft Immediately after --~gal. water added (in.): Fluid depth ts.) Minutes later: Absorption rate = .g.p.d. Peroxide treatmem (past 12 months) (Y/N) ~ If yes, g~ve date Monitoring Tube present(Y/N) x._ ~_~_ Depression over field (Y/N) Results (Pass/Fail) ~ For .~ bedrooms LIFt STATION Date installed Mauhole/Access (Y/N) High water alarm level at* Cycles tested ~ ~ Size in gallons "Pump ou" level at* ~,/,~- *Datum ~ a ~(/oa, n.n E. SEPARATION DISTANCES "Pump off' level at* Septic/holding tank on lot Absorption field on lot Public sewer main Sewer/septic service line SEPARATION DISTANCES FROM WELL ON LOT TO: ID't I ; On adjacent lots ; On adjacent lots Public sewer manhole/cleanout Lift station SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: 1 Building foundation 7~ Propert3~ line I ,~ Absorption field Water main/service line ~0~' Surfacewater/drainage ~'/]D Wells on adjacent lots > /0-"O SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Building foundation~.~ Surface water I'",~. 112) Curtain drain ]~'~ t 0 Water main/service line Driveway, parking/vehicle storage area 02 ! Wells on adjacent lots ~> /tO'~ Property line F. ENGINEER'S CERTIFICATION I certify that I have determined thrufield inspections and review of Municipal r cords' that the~l~ ~terrJ4; are tn conformance with MOA HAA guidelines in effq~on this date. ' Signature .................................................................... HAA Fee $ ~DO ~ Waiver Fee $ Date of Payment /ff - 2 3 -- ~ Date of Payment Receipt Number ~7 g ~ Receipt Number Rev. 8/95 OSS: haa.wk.doc O MUNICIPALITY OF ANCHORAGE O DIVISION OF ENVIROI~tENTAL m~LTH DEPARTMENT OF m~.~LTH AND ENVIRONHENTAL PROTECTION APPLICATION FOE HF~LTH AUTHORITY APPROVAL CERTIFICATe, General ~Inform~tion Application Date (a) Legal Description (include lot, block, subdivision, section, township, range) Location (address or directions) o o o' /Fo/ (b) Applicants Nam, Business Applicants Md~ss ~ ~ u ~ ~//~ (c) Applicant is (check one) Ltgi~ Institution Buyer ~; Other ~ (~plain); (d) Lending Ad~X~ ss (e) Real Estate Co. & Agent Address ~:~--~ ~ '? Telephone (f) Mail the HAA to the followin~ address: Type of Residence Single-Family~--~ Number of Bedrooms Water Supply Individual Well['--~ Other (describe) Community~--~ Public~--~ Note: If community well system, must have written confirmation from the State Department of Environmental Conservation attesting to the legality and status. Sewage Disposal Onsite ~ Public ~-~ Community ~-~ Holding Tank ~ Note: If community well system, must have written confirmation from the State Department of Enviromnental Conservation attesting to the legality and status. [?age 1 of 2] 5. En~ineerin~ Firm Providin~ Inspections~ Tests~ File Search~ Data and Information As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of- this Health Authority Approval shows that the on-site water supply and/or wastewater disposal system is safe, functional and edequate for the nUmber of bedrooms and type of structure indica~ed herein.. I further verify tha=, based on the information obtained from the Municipality of Anchorage files amd from my investigation and inspection, the om-site water supply and/or wsstewater disposal system is in compliance with all Municipal and State codes, ordinances, and regula- tions in effect on the c~.te of this inspection. Approved ,~ Disapproved L/ Conditio~m Terms of Conditional Approval CAUTION THE MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION (DHEP) ISSUES HEALTH AUTHORITY APPROVAL CERTIFICATES BASED SOLELY UPON THE REPRESENT- ATIONS GIVEN IN PARAGRAPH 5 ABOVE BY AN INDEPENDENT PROFESSIONAL ENGINEER REGISTERED IN THE STATE OF ALASKA. THE DHEP DOES THIS AS A COURTESY TO PURCHASERS OF HOMES AND THEIR LENDING INSTITUTIONS IN ORDER TO SATISFY CERTAIN FEDERAL AND STATE REQUIRE- MENTS. EMPLOYEES OF DHEP DO NOT CONDUCT INSPECTIONS OR ANALYZE DATA .BEFORE A CERTIFICATE IS ISSUED. THE MUNICIPALITY OF ANCHORAGE IS NOT RESPONSIBLE FOR ERRORS OR OMISSIONS IN THE PROFESSIONAL ENGINEER'S WORK. (D EP smart) RE4/eJ/D18 [Page 2 of 2] 7-19-84 A® WE.T &. DATA Well Classification Well Log P~esent (Y/N) Total Depth ~ ~/~7 ~MUNICIPALI~Y OP ANCHORAGE MUNICIPALITY OF ANCHORAGE (MOA) DEPT. OF HEAL?H & HEALTH AUTHORITY APPROVAL (HAA) ENVIRONMENTAL PROTECTION Legal Description :R , Static Water Level ~/J~.j~ Casing Height Above Ground ~/" Electrical Wiring in Conduit (Y/N) Separation Distances f~cm Wall: If A, B, c~ C, D.E.C. Approved(Y/N) /J'~ Dat~e Completed ~w-~'~w Yield Case, d t~/~-'~~ ~ of ~outi~g 'Ptmlp Set At ~/c~ Sanitary Seal on Casing (Y/N)/F-W,~ /V~ Depression Around Wellhead (Y/N) ~ To Septic/Holding Tank on Lot / ~ ~ To Nearest Edge of Absc~ption Field on Lot To Nearest Public Se~r Line Cleanout/Manhole /V/~ To Nearest Se~r Service Line on Lot ~ ~7~ Water Sample Collected By Water Sample Test Results SEPTIC/HOLDING TANK ~ATA ; On Adjoining Lots,~ / ' )~ ; On Adjoining Lots To Nearest Public Se~r Date Installed ///&/~o ~' -~ Size //~Z~ No. cf Ccmpa=tments Stan~ims (Y~) .~J Ai~-ti~t ~ps (Y~) ~B Foun~tion C~anout (Y~) ~ession o~ Ta~ (Y~) ~ ~te ~st 'P~d ~/~ ~ P~ing~intenan~ ~n~a~ ~ File (Y~) ~ ; fo~ Holding Ta~ High-Wate~ ~a~ (Y~) ~ ~~ Holdi~ Ta~ ~p~ation Distanms ~m ~ptic~oldin~ Ta~: TO Water-Supply ~11 /~o ' ~ To ~ilding Foundation To ~rty Li~ ~ ~ ~ w ~ TO Dis~sal Field ~ _' ,,-..~,.. ...,..... , Receipt % [Pa~ 1 2-15-84 Soils Rating in Absozl0tion Strata Width of Field ~ ' ~' /~J-~)~ Type of System Design Length of Field ~ ~ ' , ~" Depth of Field Gravel Bed Thickness Squa=e Met of Absorption A~ea ,~ -~ Stan~i~s ~e~nt (Y~) ~3 ,, ~ession o~ Field (Y~) /~ ~ of ~st ~a~ ~st ///~/F~ of ~p~ation Distan~ ~ ~s~ti~ Field: TO ~ildi~ Foun~tion~ ~ ~ To Existing ~ ~ndo~d S~m ~ Lot /~_~ _; ~ ~joining ~ ~ ~ ~ To S~ond~ke/~ ~j~ ~ai~~ ~ To ~i~way, P~ki~ ~ea, ~ Vehicle St~a~ ~a ~ /~ / Date Installed Size in Gallons "Pu~¢~ 0~" Level at . High Water Alarm Level at Tested for Elect=ical Codes (Y/N) Dimsnsions Manhole/Access (Y/N) "Pump Off" Level at Vent (Y/N) Pumping Cycles during Adequacy Test. M~ets MOA cc~msnts KB1/d5/s ** ** Check Permitted Bedrocm Rating Against HAA Request I certify that I have checked, verified, c= confcz~red to all MOA HAA Guidelines in effect MOA No..¢7='6~- ~...-~ ~ ',ENGiN~SRS'''~. - [Page 2 of 2] - 2-15-84 ANCHORAGE CESSPOOL PUMPING Star Route A, Box 144 ANCHORAGE, ALASKA 99502 Phone 344-2632 or 344-2453 _ - All claims and returned goods MUST be 814.1 APPLI T FiLL 'OUT UPPER NLY ' PCBperty O~wner ~//~ ~ ~ ~, ~~ ~~ ~~..~ ~ ~ Phone M~'gAddre~ ~ ~ ~/ ~ ~ ZIpCode ~ / Address ~/t ~ ~ ~ Zip C6de ~ ~ / Lending Institution ~ /,~//~ ~ ~ ~. Phone Address Zip Code Realty Co. & A~nt ~ /~ ,~ ~ ~ /~ Phone Address ~ ~ * ~ ~ Zip Code ~ ~ / St[eet Locali~ ~ / ~,~ /~ '~ ~1, , Type of Resi~nce ~gle Family ~ Multiple Family No. of Bedroo~ ~ , : ~ Other Water Supply ~ividual ' A~ACH WELL LOG. A w~l Icg is required for all wells drilled since.June 1975. ~ Community Fo~ wells drilled pdor to that date, give well depth (attach Icg if available). ~ Public Utility Sewer Disposal ~dividual Year Indiv~ual Installed: · ~ Public ~ility ~hen Connected to Public Utility: ~ Holding Tank NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH'RE~EST BEFORE ~OCESSING CAN BE INITIATED. Time Time Time Date Date Date i~--~/~ "~ Inspector Inspector Inspector ~) ~' O.~'~ I n spec~~ Field Notes: ( .~ ) APPROVED BEDROOMS *CONDITIONS OF APPROVAL ( ) DISAPPROVED ( ) CONDITIONAL A__PPROVAL* Soils Rating Date Sewer Installed Well To Absorption Area Well Log Received ~" DATE RECEIVED DATE DATE DATE MUNICIPALITY OF ANC - -- T~NVIR~ENTAL PEOTECTION DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTEC 825 L Strut - Anchorage, Alaska 99501 OCT 1980 ENVIRONMENTAL SANITATION DIVISION Telephone 264-4720 REQUEST FOR APPROVAL OF INDIVIDUAL WATER AND SEWER FACILITIES DIRECTIONS: Complete all parts o~ page 1. Incomplete requ~ will not be proce~ed Please allow ten (10) days for processing. PHONE 1. PROPERTY OWNER PROPERTY RESIDENT (If different from above) PHONE PHON~ 2. BUYER 3,~LENDING~ IN~TITUTION~/~ ~/1~ PHONE MAILING ADDRESS 4, REALTOR/AGENT PHONE MAI~ING ADDRESS ~ ~ 5. LEGAL DESCRIPTION STREET LOCATION . / 6. TYPE OF RESIDENCE ~ SINGLE FAMILY [] MULTIPLE FAMILY ~IUMBER OF~BEDROOMS [] One ~] Four [] Two [] Five ~ Three [] Six [] Other 7. WATER SUPPLY [Z~.-~I NDIVI DUAL* [] COMMUNITY [] PUBL C UTILITY * ATTACH WELL LOG. A well 10g is required for all wells drilled since June 1975. For wells drilled prior to.that date, give well depth (attach log if available.) 8. SEWAGE DISPOSAL SYSTEM [~"~-I N DI V I DUAL/ON-SITE*~ --1 PUBLIC UTILITY YEAR 0N-SITE SYSTEM WAS INSTALLED, NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED. 72-010 (Rev. 6/79) IL~j~,~, ~)~ ~ THIS SIDE FOR OFFICIAL USE ONLY 1. TYPE OF RESIDENCE NUMBER OF BEDROOMS [] SINGLE FAMILY [] ONE [] THREE [] FIVE [] OTHER [] MULTIPLE FAMILY [] TWO [] FOUR [] SIX PERMIT NUMB;=R 2. WATER SUPPLY [] INDIVIDUAL DEPTH OF WELL [] COMMUNITY DATE DRILLED [] PUBLIC UTILITY Connection Verified LOG RECEIVED 3. SEWAGi~ D|SPOSA~L SYSTEM P'ERMIT NUMBER []INDIVIDUAL/ON -SITE DATE INSTALLED []PUBLIC UTILITY Connection Verified INSTALLER []Septic Tank or [] Holding Tank Size: ' If Tank is homemade BOILB RATING give dimensions; MANUFACTURER TYPE OF TANK , ' TOTAL ABSORPTION AREA MATERIAL 4"'' .'D STANCES Septic/l~olding'Tank Absorption Area Sewer Line '- ' WELL TO: Absorption Area '~o nearest Lot Line ~ ' ' " ' ' 5, COMMENTS PROVE FOR EOROOMS [] CONDITIONAL APPROVAL (letter mus~j~ccompNny certificate) DEPARTMENTOFHEALTHANDENVtRONMEN Huisingh/Gondek Property October 7, 1980 Allen Huisingh 125 West Fireweed Lane Anchorage, Alaska 99503 Subject: T~2N R3W Section 22 W½ Lot 5(Huisingh Subdivision) Approval for your individual sewer and water facilities cannot be granted until the following items have been completed: (1) The water analysis report be delivered to this ///o Jdepartment from Chem Lab, 5633 B Street, for ur review. /(2) The well casing extended twelve(12) inches above ground level. The depression or pit around the well casing needs to be filled with impervious type soil so that it slopes away from the well casing. (3) The existing sewer sYstem is to close to the well. It Will need to be relocated one-hundred(100) feet from any well. (4) Prior to the upgrade of the sewer system, a permit will need to be issued by this department. (5) If there is a septic tank, it needs to be at least fifty(50) feet from the well. It will need to be uncovered to verify existence and pumped to verify its size. (5) A soils test will need to be obtained so that the system can be designed to meet specifications. A~len Huisingh bctober 7, 1980 Page Two If there are any further questions, please call this department at 264-4720. Sincerely, Robert C. Pratt, R.S. Associate Specialist RCP/ljw CC: National Bank of Alaska pOuch 7-025 99510 Attention: Ruth La Bar Landmark Realty 125 West Fireweed Lane 99503