Loading...
HomeMy WebLinkAboutJENKINS Plat# 78-22 Expired 03-06-78 S-4263 6 8 10 12 14 16 18 20 Performed For Leqal Qescri~tion: 2204 Cleveland Anchorage, Alaska 99503 John Jenkins (Test Hole #1) Date Performed Lot Block Subdivision 10/30./76 This ~orm Renorts Soils Lo~ yes Percolation Test__ yes N 1/2, NE 1/4, NE 1/4, SE 1/4, Sec 21, T12N, R3W ~eDth Feet Soil Characteristics Gravelly Silt (GM) Bottom of Test Was Ground Water Encountered? I¢ Yes, At what Denth? I Readinq Date Grnss Time Net Time DePth to H20 Net Dron inches inches 10/29/76' 36 i 10/30/76 22 hours 70 35 ~ 10/30/76 0 40 10/30/76 10 min. 40-1/ 1/4 10/30/76 20 min.__ 41 _ 3/4 10/30/76 ..3--0 min. ~I-1/8 1/8 10/30/76 ~0 min. 41-1/4 1/8 . 10/30/76 50 min. ' 41-1/2 1/4 _ i 10/30/76 ~ 6O_~in. 42 1/2 ercolation Rate 2"/60 Hinute Prnnosed Installation: SeeDaoe Pit Drain Field Deoth of Inlet Depth To Bottom Of Pit Or Trench Cmu~ENTS: 250 square feet drainage area required per bedroom. No ground water or bedrock encountered. Dat~: 10/30/76 6 8 10 12' 14 16 18 20 2204 Cleveland Anchorage, Alaska 99503 Performed For John Jenkins (Test Hole 2)~ate Performed Leaal ~escriDtion: Lot Block Subdivision This Form Re~ort$ Soils Loq yes Percolation Test_ N 1/2, NE 1/4, NE 1/4, SE 1/4, S~c 21, T12N, R3W Perth Feet Soil Characteristics Peat Gravelly Silt, damp (GM) Bottom of Test Hole 10/30/76 yes Yes, At what Denth? ~~ Date Gross Time Net Time Depth to H20 Net Dron inches inches 10/29/76 24 10/30/7'6'- 22 ho~rs 48-1/2 24-1/2 10/30/76 0 35 10/30~76 L0 min. 35-1/2 1_/2 10/30/76 20 min. 35-3/4 1/4 10/30/76 30 mi~.' - ~6-1/4 _ 1/2 10/30/76_ 40 min. ' 36-3/4 1/2 10/30/76 50 min. i 10/~0/76~ 60 min. 37-1/4 1/4 Percolation Rate 2.5"/60.~Ii nute Proposed Installation: Seenaoe Pit__ __Drain Field Den. th of Inlet Depth To Bottom Of Pit Or Trench Cnu~£NTS: 225 square feet drainage area required per bedroom. No ground water or bedrock encountered-Data CertifiedDate.~-~l~0/~30/~7/~6~.~,' ~ Test Performed By David Paul' 2204 Cleveland Anchorage, Alaska 99503 Per'formed For Gohn Genkins (Test Hole ~3) 0ate Performed 10/30/76 , Lenal ~escriDtion: Lot Block Subdivision This Form Renorts Soils Loq 7es Percolation Test_ yes N 1/2~ NE 1/4, NE 1/4, SE 1/4, Sec 21, T12N, R3W ~eDth Feet Soil Characteristics 2, Peat 4 6-- Silty Gravel 8 10-- 12 Gravelly Silt with occasional boulders (GM) 14 16 Bo~ 'o - es o e 18 20 Was Ground Water Encountered? No I¢ Yes, At what Denth? Date Gross Time Net Time Depth to H20 Net Dron inches inches 10/29/76 30 10/30/76 22 hours 57-3/4 2~-3/4 10/30/76 0 36 10/30/76 10 min. 38 2 10/30/76 20 min. ' .... 39-1~4 ' 1-1/4 10/30/76 30 min. 40-1~4 1 10/30/76 40 m-~n. 40-1/2 1/4 10/30/76 50 min. '~0-3/4 1/4 i.10/30/76 ~ 60 min. 41 1/4 Percolation Rate 1 ,/25 ~inute Proposed Instal ation: Seepane Pit Drain Field Deeth of Inlet Depth To Bottom Of Pit Or Trench Cnu~£NTS: 225 square feet drainaqe area required per bedroom. No ground water or bedrock encountered. Test Performed By David Paul Data Certi fi ed ~ Da%e: 10/30/76 c_ 0 THOI~ P$ON STREET 92.5 104/2