HomeMy WebLinkAboutJENKINS Plat# 78-22 Expired 03-06-78 S-4263
6
8
10
12
14
16
18
20
Performed For
Leqal Qescri~tion:
2204 Cleveland Anchorage, Alaska 99503
John Jenkins (Test Hole #1) Date Performed
Lot Block Subdivision
10/30./76
This ~orm Renorts Soils Lo~ yes Percolation Test__ yes
N 1/2, NE 1/4, NE 1/4, SE 1/4, Sec 21, T12N, R3W
~eDth
Feet
Soil Characteristics
Gravelly Silt (GM)
Bottom of Test
Was Ground Water Encountered?
I¢ Yes, At what Denth?
I Readinq Date Grnss Time Net Time DePth to H20 Net Dron
inches inches
10/29/76' 36
i 10/30/76 22 hours 70 35
~ 10/30/76 0 40
10/30/76 10 min. 40-1/ 1/4
10/30/76 20 min.__ 41 _ 3/4
10/30/76 ..3--0 min. ~I-1/8 1/8
10/30/76 ~0 min. 41-1/4 1/8
. 10/30/76 50 min. ' 41-1/2 1/4 _
i 10/30/76 ~ 6O_~in. 42 1/2
ercolation Rate 2"/60 Hinute
Prnnosed Installation: SeeDaoe Pit Drain Field
Deoth of Inlet Depth To Bottom Of Pit Or Trench
Cmu~ENTS: 250 square feet drainage area required per bedroom.
No ground water or bedrock encountered.
Dat~: 10/30/76
6
8
10
12'
14
16
18
20
2204 Cleveland Anchorage, Alaska 99503
Performed For John Jenkins (Test Hole 2)~ate Performed
Leaal ~escriDtion: Lot Block Subdivision
This Form Re~ort$ Soils Loq yes Percolation Test_
N 1/2, NE 1/4, NE 1/4, SE 1/4, S~c 21, T12N, R3W
Perth
Feet
Soil Characteristics
Peat
Gravelly Silt, damp (GM)
Bottom of Test Hole
10/30/76
yes
Yes, At what Denth? ~~
Date Gross Time Net Time Depth to H20 Net Dron
inches inches
10/29/76 24
10/30/7'6'- 22 ho~rs 48-1/2 24-1/2
10/30/76 0 35
10/30~76 L0 min. 35-1/2 1_/2
10/30/76 20 min. 35-3/4 1/4
10/30/76 30 mi~.' - ~6-1/4 _ 1/2
10/30/76_ 40 min. ' 36-3/4 1/2
10/30/76 50 min.
i 10/~0/76~ 60 min. 37-1/4 1/4
Percolation Rate 2.5"/60.~Ii nute
Proposed Installation: Seenaoe Pit__ __Drain Field
Den. th of Inlet Depth To Bottom Of Pit Or Trench
Cnu~£NTS: 225 square feet drainage area required per bedroom.
No ground water or bedrock encountered-Data CertifiedDate.~-~l~0/~30/~7/~6~.~,' ~
Test Performed By David Paul'
2204 Cleveland Anchorage, Alaska 99503
Per'formed For Gohn Genkins (Test Hole ~3) 0ate Performed 10/30/76 ,
Lenal ~escriDtion: Lot Block Subdivision
This Form Renorts Soils Loq 7es Percolation Test_ yes
N 1/2~ NE 1/4, NE 1/4, SE 1/4, Sec 21, T12N, R3W
~eDth
Feet Soil Characteristics
2, Peat
4
6--
Silty Gravel
8
10--
12
Gravelly Silt with occasional
boulders (GM)
14
16
Bo~ 'o - es o e
18
20
Was Ground Water Encountered? No
I¢ Yes, At what Denth?
Date Gross Time Net Time Depth to H20 Net Dron
inches inches
10/29/76 30
10/30/76 22 hours 57-3/4 2~-3/4
10/30/76 0 36
10/30/76 10 min. 38 2
10/30/76 20 min. ' .... 39-1~4 ' 1-1/4
10/30/76 30 min. 40-1~4 1
10/30/76 40 m-~n. 40-1/2 1/4
10/30/76 50 min. '~0-3/4 1/4
i.10/30/76 ~ 60 min. 41 1/4
Percolation Rate 1 ,/25 ~inute
Proposed Instal ation: Seepane Pit Drain Field
Deeth of Inlet Depth To Bottom Of Pit Or Trench
Cnu~£NTS: 225 square feet drainaqe area required per bedroom.
No ground water or bedrock encountered.
Test Performed By
David Paul Data Certi fi ed ~
Da%e: 10/30/76
c_ 0
THOI~ P$ON STREET
92.5
104/2