HomeMy WebLinkAboutDOGWOOD LT 2Dogwood
Lo1' 2
, 015- 501
-28
GREAI~R ANCHORAGE AREA BOROugH
Department of Environmental Quality
3330 C S~ree~
Anchorage, Alaska gg§03
.s w^o
LOCATION LEGAL DESCR
SEPtiC TANK:
DISTANCE
FROM WELL /~'~
INSIDE LENGTH.
R~.,,/.,~,~.../.,~ ~ NUMBER OF ,~
MANUFACTURE MATE RIAL - COMPARTMENTS
INSIDE WIDTH __ LIQUID DEPTH LIQUID CAPACITY/~-*~"~GALLON$.
TILE DRAIN FIELD:
D~STANCE FROM WELL /g:~'
NUMBER OF LINES 1
ABSORPTION AREA ?~¢
DEPTH:
~ /~ / TOTAL LENGTH
FOUNDATION /~ NEAREST LOT LINE OF LINES
DISTANCE BETWEEN LINES ~/~' TRENCH WIDTH;~IN. TOTAL EFFECTIVE
SQ. FT. LENGTH OF EACH LINE ~TZ~-// j
i DEPTH OF FILTER
TOP OF TILE TO FINISH GRADE ~ MATERIAL BENEATH TILE__~ ~ ABOVE TILE 7 IN.
WELL:
BUILDING
FOUNDATION
CESSPOOL
APPROVED
CONSTRUCTION
NEAREST
LOT LINE_
OTHER SOURCES
DISAPPROVED
NEAREST SEPTIC
SEWER LINE , TANK
REMARKS
DEPTH
SEEPAGE
SYSTEM
DISTANCE FROM:
DISTANCES:
DIAGRAM OF SYSTEM
INSTALLED BY:
SEWER LINE DEPTH:
PIPE MATERIAL'~-'/~-~1~/~1¢
LOT SLOPE:
REMARKS:
Form EQ-032
r'IUI'-J ! C: I Pt-4L I T'-r' OF FiI'-,IC:HORI--]
2510 E. TUDOR RD., RNCHORRGE., IlK.
SRR BOX 474E
PERMIT NO.
RPPLICRNT JRMES BUMGRRDNE~
LOCRTION OFF i04TH 8VE OFF BIRCH
LEGRL L2 DOGWOOD SUBD
WELL 8r-JD ON--S I TE SEWER PERt4 I T
3 4 4-t9 ~._-.-:
LOT. SIZE 49005 SQURRE FEET
TYPE OF SOIL RBSORBTION SYSTEM IS: TRENCH
MRXIMUM NUMBER OF BEDROOMS = 4
SOIL RRTING <SQ FT?BR)= i50
THE REQUIRED SIZE OF THE SOIL RBSORPTION SYSTEM IS:
I;:,EF'TH= :1.2 LENGTH= 38 m~RRVEL DEPTH= :3
THE LENGTH DIMENSION IS THE LENGTH (IN FEET) OF THE TRENCH OR DRRINFIELD.
THE DEPTH OF R TRENCH OR PIT IS THE DISTRNCE BETWEEN THE SURFRCE OF THE
GROUND RND THE BOTTOM OF THE EXCRVRTION (IN FEET).
THERE IS NO SET WIDTH FOR TRENCHES.
THE GRRVEL DEPTH IS THE MINIMUM DEPTH OF GRRVEL BETWEEN THE OUTFRLL PIPE
RND THE BOTTOM OF THE EXCRVRTION (IN FEET).
REQUIRED SEPTIC TRNK SIZE= t250 ~GRLLONS
BRCKFILLING OF RN¥ SYSTEM WITHOUT FINRL INSPECTION RND RPPROVRL BY THIS
DEPRRTMENT WILL BE SUBJECT TO PROSECUTION.
MINIMUM DISTRNCE BETWEEN R WELL RND RN¥ ON-SITE SEWRGE DISPOSRL SYSTEM IS
i00 FEET FOR R PRIVRTE WELL OR 200 FEET FOR R PUBLIC WELL.
WELL LOGS RRE REQUIRED RND MUST BE RETURNED TO THE DEPRRTMENT WITHIN ~0 DRYS
OF THE WELL COMPLETION.
SPECIFICRTIONS RND CONSTRUCTION DIRGRRMS 8RE RVRILRBLE TO INSURE PROPER
INSTRLLRTION.
PERt4 I T VRL I D FOR ONE YERR FROr~ I$SUE
I CERTIFY THRT
i: I RM FRMILIRR WITH THE REQUIREMENTS FOR ON-SITE SEWERS RND WELLS RS SET
FORTH BY THE MUNICIPRLITY OF RNCHORRGE.
2: I WILL INSTRLL THE SYSTEM IN RCCORDRNCE WITH THE CODES.
3: I UNDERSTRND THRT THE ON-SITE SEWER SYSTEM MRY REQUIRE ENLRRGEMENT IF THE
RESIDENCE IS RE TO INCLUDE MORE THRN 4 BEDROOMS.
-.'MODELED_
SIGNED :t
ISSUED BY__ -~~--
GREATER ANCtlORAGE AREA
Department. of Environmental (}ualitY
3330 "C" Street
Anchorage, Alaska 99503
SOILS LOG - PEROLATION TEST
Performed for_JjLk~]~.?~__~,_..~ U ~G~ D ~ ~ ~ ~ate Performed~-~ 4" 7~
Legal Descripdon:' Loy~~oGW0.~D SO6_oIY~Sz0~
This form reports: ~ls ,l~g .... X~ Percolation :es~
Depth
Feet
2 -
4-
5-
6-
7-
8-
9-
10-
GvJ-TM
~4-
~G~ .....
Was ground water encountered?
Acres '%/~o.
If yes, at what depth?'__
Reading
Da te
Gross Time
Net Time
Depth to Water Net kJrop
Percolation, rate minute. '~Drain Field
-Proposed ir~stallat~o'--~-n'~ Seepa'ge Pit
Depth of Inlet ~. Depth to bottom of pit qr trench ._~
.... TIME DRILL LOG , CASING !
.... ,~ ~) STATICLEVEL ,~, , ~ GPM-YIELD
Municipality of Anchorage
Development Services Department
Building Safety Division
On-Site Water and Wastewater Program
4700 Bragaw Street
P.O. Box 196650
Anchorage, AK 99519-6650
www.muni.org/onsite
(907) 343-7904
CERTIFICATE OF ON-SITE SYSTEMS APPROVAL
FOR A SINGLE FAMILY DVVELLING
Parcel I.D. 015-501-28
GENERAL INFORMATION
Complete legal description
Location (site address)
DOGWOOD LOT 2
COSA# 0
ExpiratiOn Date:
5550 E 104TM AVENUE, ANCHORAGE, AK 99507
Current Property owner(s) LESTER & NANCY NEWELL Day phone
Mailing address 5550 E 104TM AVENUE, ANCHORAGE, AK 99507
Lending agency.
Day phone
Mailing address
Real Estate Agent
DAVE SMITH -- W/DYNAMIC
Day phone
Mailing Address
Un/ess otherwise requested, COSA will be held by DSD for pickup.
NUMBER OF BEDROOMS: 4
TYPE OF WATER SUPPLY:
Individual Well
Individual Water Storage
Community Class .__ Well
Public Water System
TYPE OF WASTEWATER DISPOSAL:
Individual On-site
Individual Holding Tank F"]
community On-site []
Public Sewer
The Municipality of Anchorage Development Services Department (DSD) issues Certificates of On-Site Systems
Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil
engineer registered in the State of Alaska. Certificates of On-Site Systems Approval are required for the transfer of
title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water
supply system. DSD also issues COSAs upon request to homeowners. Certificates of On-Site Systems Approval
are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued
with new water sample results. (Certificates may be reissued for a period of up to one year with valid water
samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system.
The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work.
4. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation,
based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application,
shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the information
obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water
supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes,
ordinances~ and regulations in effect at the time of installation.
Name of Firm ARCTERRA CONSULTING, INC. Phone 868-3792
Address 20441 PTARMIGAN BLVD., EAGLE RIVER, AK 99577
Engineer's Printed Name KENNETH M. DUFFUS Date 01/12/2011
Engineer's Comments: This investigation was completed in compliance with ADEC and MOA regulations. The
assessment of the condition of the well and septic applies only to the conditions as of the day tested; The flow
and absorption rates may change due to subsurface conditions that may not be observed from the sUrface,
changes inland use, local soil characteristics, groundwater levels that may fluctUate dudng the year and the
water usage of the family being served by the system. The operational life of all well and septic systems are
subject to these various and dynamic characteristics and are outside the control of the
evaluator of the well and septic system. Therefore,
ArcTerra can not give any estimate of how long a
system will function satisfactory for current or future
occupants or can ArcTerra guarantee that no unseen
encroachments, deficiencies or discrepancies exist.
DSD SIGNATURE
'~'" Approved for J~J
Disapproved.
Conditional approval for
bedrooms.
bedrooms, with the following stipulations:
Attachments: COSA Checklist
Septic System Advisory
Well Flow Advisory
Nitrate Advisory
X
Arsenic Advisory
Maintenance Agreements
Supplemental Engineer's Report
Other
Original Certificate Date: /- ~. (.o -//
Municipality of Anchorage
Development Services Department
Building Safety Division
On-Site Water & Wastewater Program
4700 Bragaw Street
P.O. Box 196650
Anchorage, AK 99519-6650
www.muni.org/onsite
(907) 343-7904
CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST
Legal Description: DOGWOOD LOT 2
A. WELL DATA
Well type PRIVATE IfA, B, or C provide PWSID #
Date completed '6/16/1976 Sanitary seal (Y/N) Y__
Total depth 60.7 ff. Cased to 60.7 ff.
FROM WELL LOG
Date of test 6/1976
Static water level 40 f.
Well production 5 g.p.m.
WATER SAMPLE RESULTS:
Parcel ID:
Coliform NF.G colonies/100mL Nitrate
Arsenic: ND .mg/I Date of sample: 1/5~22011
SEPTIC/HOLDING TANK DATA
Tank Type/Material Se,ftc/Steel
Number of Compartments _2
High water alarm (Y/N) N
Well Log (Y/N) _.Y
Wires properly protected (Y/N) Y_.
Casing height (above ground) 18 in.
AT INSPECTION
45 ff.
5.4 g.p.m.
__ mg/L
Collected by:. ArcTerra
Date installed 611976 'Tank size 1250 gal.
Cleanouts (Y/N) _Y_ Foundation cleanout (Y/N) __Y Depression over tank (Y/N) N
__Date of pumping 1/4/2011 Pumper A+
C. ABSORPTION FIELD DATA
Date installed 6/1976 Soil rating (g.p.d./ff2 or ff2/bdrm) 150 System type Deep Trench
Length 44 f. Width --3 ff. Gravel below pipe 8__ff. Total depth 9._~7 ff. (Measured 1/4111)
Eft. absorption area 704'ft2 Monitoring tube Y Depression over field N
Date of adequacy test '1/5/11 Results (Pass/Fail) Pass For 4 bedrooms
Fluid depth in absorption field before test 35 in. Water added 1050 gal. New depth 35
Elapsed '13me: 0__ min. Final fluid depth 35 . in. Absorption rate >= 600+ g.p.d.
Any rejuvenation treatment (past 12 mo.) (Y/N & type) Nlfyes, give date --_~-
in.
DJ
LIFT STATION
Date installed
"Pump on' level at
Datum
in.
E. SEPARATION DISTANCES
Size in gallons
"Pump off' level at ~
Cycles tested
in.
SEPARATION DISTANCES FROM WELL ON LOT TO:
Septic tank/lift station on lot 100'+
Absorption field on lot 100'+
Public sewer main
Sewer/septic service line 25'+
Animal containment areas 50'+
Manhole/Access (Y/N)
High water alarm level at in.
Meets alarm & circuit requirements?
On adjacent lots 100'+
On adjacent lois 100'+
Public sewer manhole/Cleanout 100'+
Holding tank 100'+
Manure/animal excrete storage areas
100,+
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO:
Building foundation $'+ Property line =3'+
Water main 10'+ Water service line
Wells on adjacent lois 100'+
10'+
Absorption field `;'+
Surface water 10o'+
SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO:
Property line lo'+ Building foundation 10'+
Water main 10'+
Water Service line 10'+ Surface water 100'+
Curtain drain .;0'+ (None Y~town)
Driveway, parking/vehicle storage 10'+
Wells on adjacent lois 100'+
F. COMMENTS
*Vacant system surcharged w/2000 gallons prior to testing, l~ield fluid levels r~a!ped consf.~_n_t duH~,
sii~chai-~e and te~in§ at approximately 22.5" below lateral. ~ ~-~ ~,v'~ ~&'~ ir/~/~D ~
- ~~/~/~'od~ ~~sna~e:en./nd '-.~~~
. Enoinee(s Pgnted Name KE~E~ M. D~S :'~a~~~:'~~>~;:.~
Date 1/1E~ll '~:*'~
. COSA Fee $490.00 Waiver Fee $
ate /- I-- / / Oate
R~ceipt Number O ~ ~ ~ ~ C~ ~ecei~ Number
(Rev. 11/05)
............ S.G S .......
SGS Reft# 1110056001
Client Name ArcTerra Engineering and Surveying Printed Date/Time 01/11/2011 9:07
Project Name/# Dogwood L2 Collected Date/Time 01/05/2011 13:15
Client Sample ID Dogwood L2 Received Date/Time 01/05/2011 14:45
Matrix Drinking Water Technical Director Stephen C. Ede
Sample Remarks:
Allowable Prep Analysis
Parameter Results LOQ Units Method Container ID Limits Date Date Init
Metals by ICP/MS
Arsenic
ND 5.00 ug/L EP200.8 C (<10) 01/07/11 01/10/11 NRB
Waters Department
Total Nitrate/Nitrite-N
2.09 0.100 mg/L SM204500NO3-F B (<10) 01/05/11 AYC
Microbiolo~ Laboratory
E. Coli
Total Coliform
Negative 1 100mL SM20 9223B A 01/05/11 DLC
Negative 1 100mL SM20 9223B A 01/05/11 DLC
104TH AVE
Z
O
O
N89'58'25"W
(N89'57'50"W R) 164.84'
10' UTILITY ESMT
/ /
LOT 2
/
/
hJ SEPTIC
(T~)
DECK
WELl_
/
S89'58'00'E
2' CANT 36.4'
24.0'
L0 CO
24.0' 34-.0'
12.1'
164.84'
SOUTH
BLM LOT
ANCHORAGE RECORDING DISTRICT, ALASKA
AS-BUILT OF:
DOGWOOD SUBDIVISION
LOT 2 PLAT 73-126
~ = FND 1/2" REBAR
SURVEY CERTIFICATE: I, John L. Schuller, Have conducted a
physical survey of this property as shown on this drawing and that the "' A' ':
~mprovements situated hereon are within the property lines and no
enchroachments exist other than noted. Under no circumstance should I ['~.....' ¢. ?~TH ~../../I'~
any information on this drawing be used for construction of fences ....
structures, improvements, or for establishing boundary lines. [~ ~ ' :;.~' ' '~~.' ~. '~
EXCLUSION NOTES: It is the owners responsibility to determine /
the existence of any easements, covenants, or restrictions which ] '~/,"..... ~L~" 1040 8 ...',,~
do not appear on the recorded subdivision plat·
WOI~K O~o~.fl NUMBER: JAN5. 2011 ]1"=40' E-.Nbkndeng·ok. net /
OLS / 2537 110101 [
~-~ ~.I~ LAND
.,..:
~chorage, ~aska 99508
(007) ~7-1455 office
(907) 274-499~ fax