Loading...
HomeMy WebLinkAboutDONAHO HOMESTEAD #1 BLK 2 LT 3BDonahoe Homestead #1 Block 2 Lot 3B #050-211-83 Municipality of Anchorage Page —j—of DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 • Anchorage, Alaska 99519-6650 • Telephone: 343-4744 On -Site Wastewater Disposal System and/or Well Inspection Report Permit Number: 7SWU316 PID Number: 050 -A -CS Name: &AAecsm Wastewater System: New ❑ Upgrade Addres � �K�� �r- 4t 9 ABSORPTION FIELD Phone: (C l No. of Bedpgoms: y Deep Trench El Shallow Trench ❑ Bed 11 Mound ❑ Other LEGAL DESCRIPTION Soil Rating: Os (o Total Depth from original grade: 49 GPD/S . Ft Lot: Block: Jn� A,Subdivision: j� / rt 313 a Depth to pipe bottom from original grade: 1 Gravel depth beneath pipe 5-1 1 ti✓A if 3Ft. Ft. Township: _, Range: _ Section: �— Fill added above original grade: ve Gralength: too 1 � " � Ft. Z -rG T%L Ft. WELL'�jb�� ❑ New ❑ Upgrad Gravel width: ^'� � a Number of lines: an lines: ij Ft. Ft. Classification (Private, A,B,C): Total D Cased To: Total absorption area: Pi ee material: .' Ft. dtoll i Ft. how Q. F SIM Driller: Date Drilled: Static Water Level: Installer; Date installed: Ft. Yield: Pump Set at: Casing Height Above Ground: TANK GPM Ft. Ft. SEPARATION DISTANCES XSeptic ❑ Holding ❑ S.T.E.P. To Septic Absorption Lin Holding Public/Private Manuf ct rer: Capacit in 11 s: in From Tank Field Station Tank Sewer Lines f' p Welh sf,,0, O(.(J �� ^ �� OL Material: eG' Numbe f Compartments: Watere )od+- 104 —" —' LIFT STATION Lot ,,.� Size in gallons: Manufacturer: Line �1 >� �Ci+- J �" �� Foundation 151 1+ �' "Pump on" level at: P?11" level at: High water alarm at: Curtain /�®� �W Pump M odel Electrical Inspections performed by: Drain Remarks: BENCH MARK Location and Description: J Assumed Elevation:y� W S & S ENGINEERING .0Inspections a, performed by: 1S a,r Ea le River, Alaska 99577 2nd 1 t'' ^% ROBERT C. COWAN r 3rd Z�t Department of He Ith an u Services approva CE - 8801 ,i.�d fr r a'•., ,. ^\ Reviewed and approved by Date: 72-013 (Rev. 9/91) MOA 25 Permit No. SW960310 Page 2 of 2 Municipality of Anchorage DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 • Anchorage, Alaska 99519-6650 • Telephone: 343-4744 On -Site Wastewater Disposal System and/or Well Inspection Report Legal Description: LOT 3B, BLOCK 2, DONAHO HOMESTEAD #1 PID No.: 050-211-83 72-013 A (Rev. 9/91) MOA 25 q B 15'UTIL. ESMT. 2.0' ------ -------- ------- -----18.0' 6.5' tO 6.0' I -b-i FL TF 32.0' 4.0' ALT. SITE N D L2 33.5' 5.5' C01 37.5' 5.5' A TI 1#2 C _01 2 58.0' 0.0' 57.5' 9.5' - I T03 50.0' 7.5' C 4 67.5' 6.0' WATER LINE 4 66.5' [-M---2 4.5' DRM i w F_/_WA FDD NOSE ST1 'E- I NEW 1 50 GAL. 10' MN. o DBL1 COi DBL2 NEW TRE CHES MT1 - CO2~ _ �Q MT2 '003 C04 _ I 4� I (t EY BOX INSTALLED FLOW SPLITTE OT EXTENDED ABOVE GR DE) CITATION STR ET ST 1 ST2 C01 = 97.2' CO2 = 95.6' CO3 coo 94.8' 93.4' s7.t FINAL RADE C01 CO3 SCALE 1" = 40' CO2 MT1 C04 MT2 91.5' 1250 AL 91.3' S.T.,.........,� •• CO3 = 90.8' C04 = 90.8' cot= CO 90.9' = 90.6' R .1`���•••� �� "'. a+��t fx �} .," _....1 '•�_ .� ROBERT C. COWAN �r+��G�J�"•tae. CE' SF3O� NO WAT• FOUND `•.��i✓ "�. 79.7' B.O.H. ��:'�„ °b• .. 72-013 A (Rev. 9/91) MOA 25 M64 ropy MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND HUMAN SERVICES P.O. BOX 196650, 825 "L" STREET, ROOM 502 ANCHORAGE, ALASKA 99519-6650 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT PERMIT NUMBER:SW960310 DESIGN ENGINEER:S & S ENGINEERING OWNER NAME:GREGG GUNNARSON OWNER ADDRESS:P.O. BOX. 771504 EAGLE RIVER, AK. 99577 PARCEL ID:05021183 LEGAL DESCRIPTION: DONAHO HOMESTEAD #1 BLK 2 LT 3B LOT SIZE: 25999 (SQ. FT.) NUMBER OF BEDROOMS: 4 THIS PERMIT: 4 THIS PERMIT IS FOR THE CONSTRUCTION OF: DISPOSAL FIELD /SEPTIC TANK SYSTEM ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH: PAGE 1 OF 1 aofvN aAd ZIVC stioup>w /0Al& DATE ISSUED: 9/24/96 EXPIRATION DATE: 9/24/97 1. THE ATTACHED APPROVED DESIGN. 2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS 15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80). 3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY CALLING 343-4744 ( 24 HOURS ) (NOT REQUIRED FOR WELL ONLY PERMIT) 4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING WEATHER MUST BE EITHER: A. OPENED AND CLOSED ON THE SAME DAY B. COVERED, SEALED AND HEATED TO PREVENT FREEZING 5. THE FOLLOWING SPECIAL PROVISIONS. SPECIAL PROVISIONS: TO ENSURE EQUAL DISTRIBUTION OF EFFLUENT TRENCHES A FLOW SPLITTER/DIVIDER MUST BE DOWNSTREAM RECEIVED B ISSUED BY: BETWEEN INSTALLED DATE: HEALTH AUTHORITY APPROVALS SEWER & WATER MAIN EXTENSIONS SEWER & WATER INSPECTION ENGINEERING STUDIES AND REPORTS WELL INSPECTION & FLOW TEST SITE PLANS ROAD DESIGN SOIL TEST PERCOLATION TEST STRUCTURAL& MECHANICAL INSPECTIONS ON SITE WASTEWATER DISPOSAL SYSTEM DESIGN S &S1 ;IneeR1nq DMVER, J LASKA / August 27, 1996 MUNICIPALITY OF ANCHORAGE Department of Health and Human Services P.O. Box 196650 Anchorage, AK. 99519 ROBERT C. COWAN, P.E. ROBERTA. SHAFER, P.E. CIVIL ENGINEERS (907) 694-2979 FAX (907) 694-1211 REFERENCE: Lot 3B, Block 2, Donaho Homestead, Addn #1 Request you issue a permit to install a septic system to serve the proposed four bedroom house on the referenced property. Test holes were excavated and percolation tests performed. The approximate location of the test holes are located on the attached site plan. At the time of excavation, no water was encountered in test holes and after seven day ground water monitoring, the monitoring tubes were found to be dry. This property has enough area for a future septic upgrade which can be seen on the attached site plan. This property is served by a Community Water System. We do not anticipate any adverse effects on neighboring wells, septic systems or drainage patterns by the installation of the proposed septic system. If you require additional information, please contact us. Sincerely, Robert C. Cowan, P.E. RCC/gk Enclosure MICipEA✓IRONM Otr E&74RyO�GE SFp VICES DIVISION 04 1996 RrCFI VSD 17034 NORTH EAGLE RIVER LOOP • SUITE 204 • EAGLE RIVER, ALASKA 99577 1" - 50' SITE PLAN DESIGN SCALE HIGI-I 11LsTI+'I+, DRIVE M 00 N1NUi02 fo] C] .'O m •. Z 0(-) rte. nLf)� O C y r a -t In Z m ODA d I r �o m � O G� _ rsj D co D G H m[T1 \ r 0 Z r U' to o W D i--J p �;u Ln 0 co Krn ro II X0.3 r? j 0')0-) Ln 3 pp 0 W z sIlIQVH zllHM ,001 a o y °° Z Lf) c/)o t� W I1 'N——W— —W(�T- �z 1V � n MiO P nao g v foM —. 1 'kO Z - 4 < Z p� N m �� 1 11 _j0U) m I F 00t NIH11A� 1 ui ➢ < ➢ C x r"b 11 1 m DDm I + Sl�3M ON I - ` . m Z - I Z --j �1 0 11 _ 1 ` Zro r D I d Cm n=ljw C7 no 111 j1 0 m Q I j stn CA��Z� o s� ND 1 1111 Z➢D��-ri-+� bZ --q I �r3 rN Qo�Tz-i oo�nx cmo-i➢ _ 00 vNwce()0 VIA , sillo � ORIVkO� a Z oi rriZnO CC(4 100 Zo K z 56 ➢ m 1 H r'7 Q I o m v 2`�'wmZ y [� ➢ II� II � vtn � NA m 17: I I `I I ri O C7 0 (Xi rr j it ly IO> N_ n I y. II II �O0 zM f \� r� `y Z -- ------------------ ---IJ - ----� z; o V ' LO D / 10' UTIL. ESMT. z p O (' Q N i o o F- 0 00 i �; ------------ "oV 45 at A v %i1 zD N' �+ ° h m / '3 ;rn S^ ay; ➢ O I -vyM A 1 71 a00 n O m1g �- :+ :4 �yy FH - i♦fir=' . rn 'f, .r N,lk ` � E Q i)NEft 1%k) 10 e Municipality of Anchorage : 4 9 T H DEPARTMENT OF HEALTH & HUMAN SERVICES • • • • . • • : • •.� 825 "L" Street, Anchorage, Alaska 99502-0650 /• • • • • • / SOILS LOG — PERCOLATION TEST d01 �,'• I, Ek J. :, .gFER,P.E. •�,i000 PERFORMED FOR: 6 c2L,'1(�_lxilkJ DATE PERFORM �t�111�� '•M� LEGAL DESCRIPTION: L,5:>V 7.- Township, Range, Section: Vj %GL CPTH _ n L AIA Ae 4,1—/ &--, 1 SLOPE SITE PLAN 15- 16- 17 (RIEET) IJV" I �y r ✓ .V i 12- 1/0 Mt� 2 3 14- 14 r �• 4 5 6 of C 8 . %- :6�1 9- 10 10- dµ' WAS GROUND WAT .4 ENCOUNTERED? 15- 16- 17 me 12- 1/0 Mt� 3 13- 14- 14 151617 81920 18- 19- 20 COMMENTS S IF YES, AT WHAT L O DEPTH? P E Depth to Water Alter - Monitoring? erMonitoring? Date: ®® me Depth • .. Mt� PERCOLATION RATE -b (minutes/inch) PERC HOLE DIAMETER 7 TEST RUN BETWEEN % FT AND (a FT s A S ENGINEERING PERFORMED BY:ver I . CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WIT STXfE'AIVD"AfPJAWRL GUIDELINES IN EFFECT 91N THIS DATE. DATE: 13- Iq 72-008 (Rev. 4/85) e Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG - PERCOLATION TEST � 4 9, I• e4` ' . %� � 1 If PERFORMED FOR: (- L-2--216 I%=>. 1 fes+ DATE PERFORM LEGAL DESCRIPTION: Depth • ... (6EPJT 2 3 4- 5 5 o 8 9 10 11 12 r� 13 14 15- 16- 17 51617 18 19- 20 COMMENTS Township, Ranqe, Section: WAS GROUND WAl ENCOUNTERED? IF YES, AT WHAT DEPTH? SLOPE Depth to Water AA —I3-9 Monitoring? ��_ Date: t A-iJ SITE PERCOLATION RATE 1,C)(minutes/inch) PERC HOLE DIAMETER TEST RUN BETWEEN FT AND 6 FT PERFORMED BY: 'yjfZO34 Ragle RiNer Leen Read No A94 CERTIFY THAT THIS TEST WAS PERFORMED IN 77 ACCORDANCE WITH TtIVAiTE�QNO MUNICIP L GUIDELINES IN EFFECT ON THIS DATE. DATE: ^ 13— W 72-008 (Rev. 4/85) Depth • ... PERCOLATION RATE 1,C)(minutes/inch) PERC HOLE DIAMETER TEST RUN BETWEEN FT AND 6 FT PERFORMED BY: 'yjfZO34 Ragle RiNer Leen Read No A94 CERTIFY THAT THIS TEST WAS PERFORMED IN 77 ACCORDANCE WITH TtIVAiTE�QNO MUNICIP L GUIDELINES IN EFFECT ON THIS DATE. DATE: ^ 13— W 72-008 (Rev. 4/85) S &A ROBERT C. COWAN, P.E. ROBERTA. SHAFER, P.E. pneeRlnG CM -SITE WASTEWATER DISPOSAL 5YISTEM EAGLE CIVIL ENGINEERS �A�A CONSTRUCTION PRACTICES and FAX(907)694 -1211 %/ MATERIAL SPECIFICATIONS REFERENCE: Lot 3B, Block 2, Donaho Homestead, Addn. #1 HEALTH AUTHORITY August 27, 1996 APPROVALS GENERAL: SEWER & WATER MAIN EXTENSIONS 1. The scope of this project includes the installation of a 1250 gallon septic tank and a leachfield trench to serve the proposed four bedroom residence located on the referenced property. SEWER & WATER INSPECTION 2. Construction shall be in accordance with the approved site plan and design drawings, Municipal permit with any special provisions or conditions, and all applicable State and Municipal Wastewater Disposal ENGINEERING STUDIES Regulations. AND REPORTS 3. The contractor shall be responsible for obtaining any necessary underground utility locates. WELL INSPECTION 4. Unless specifically agreed otherwise, the property &FLOW TEST owner shall be responsible for final grading areas subsequently depressed from soil settling. 5. Contractors installing wastewater disposal systems SITE PLANS must be certified by the Municipal Health Department for system installations. Owners installing their own systems must also receive prior approval from the Municipal Health Department. ROAD DESIGN EPTIC TANK INSTALLATION: SOIL TEST 1. A septic tank is to be constructed by a certified septic tank manufacturer. Construction shall include two 4" cleanouts for pumping access. PERCOLATION 2. The septic tank shall be sufficiently bedded to TEST prevent settling or shifting of the tank. 3. All standpipes on the septic tank shall extend a minimum of 12 inches above final grade. STRUCTURAL& MECHANICAL INSPECTIONS ON SITE WASTEWATER DISPOSAL SYSTEM DESIGN 17034 NORTH EAGLE RIVER LOOP • SUITE 204 • EAGLE RIVER, ALASKA 99577 Page Two Lot 3B, Block 2, Donaho Homestead, Addn #1 August 27, 1996 4. Septic tanks installed with less than 4 ft. of cover shall be insulated. 5. A foundation cleanout shall be installed one to four feet from the building foundation. In the line between the tank and the leachfield there shall be two adjacent cleanouts (unless an effluent pumping system exists within the septic tank). These cleanouts shall be located on undisturbed soil not more than 10 ft. from the tank. The first cleanout, in line, shall be to clean toward the leachfield. The second cleanout shall be to clean toward the septic tank. 6. Final grading over the septic tank shall be such that a positive slope exists away from the septic tank. ABSORPTION TRENCH/DRAINFIELD INSTALLATION: 1. Excavate the proposed trench to the dimensions shown on the design. The bottom of the excavation shall be within 2 inches of level. If the sidewalls of the excavation become smeared, they must be raked or scratched (ruffed -up) before gravel (sewer rock) placement. 2. Once the gravel is installed, the distribution pipe is to be installed level with the perforations faced downward. Gravel is then to be placed over the distribution pipe to provide a minimum of 2 inches of cover over the pipe. 3. A silt barrier must be installed between the final gravel layer and the native soil backfill. Ensure the silt barrier covers the entire gravel surface before placing backfill. 4. Monitor tubes shall be of four (4) inch diameter, installed approximately in the locations shown on the design, and extend a minimum of 12 inches above final grade. The portion of the monitoring tube extending through the gravel shall be perforated from the bottom of the trench to the invert of the distribution pipe. This is equivalent to the effective depth of the gravel as noted on the design. Page Three Lot 3B, Block 2., Donaho Homestead, Addn #1 August 27, 1996 5. Backfill over the final gravel layer must not be less than twenty-four (24) inches. Insulation must be installed when the backfill depth is less than thirty-six (36) inches. The finish grade over the trench must be mounded to prevent the formation of a depression after settling. MINIMUM MATERIAL SPECIFICATIONS: 1. Any septic tank proposed for installation must be constructed by a Municipally approved septic tank manufacturer. 2. The following pipe materials are approved for use in septic system installations in the Municipality of Anchorage: Type of Pipe Perforated Solid Cast Iron Yes Yes ASTM D3034 (PVC) Yes Yes ASTM F810 (HDPE) Yes No ASTM D2662 (ABS) Yes Yes Use of a type of pipe other than listed above must be approved by the inspecting engineer. 3. Insulation shall be at least 2" thick extruded direct burial_ polystyrene (Dow Chemical Company Styrofoam HI or equal). 4. Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Fernco, or equal). 5. A permeable nontoxic silt barrier (Typar 3401, Mirafi 140N, or equal) must be installed between the final leachfield gravel layer and the native soil backfill. 6. All leachfield gravel (sewer rock) shall be 0.5"-2.5" screened gravel with less than 3% passing the #200 sieve. 7. When sand is being used as a filter material, its gradation specifications must conform to current M.O.A. or D.E.C. requirements. Page Four Lot 3B, Block 2, Donaho Homestead, Addn #1 August 27, 1996 INSPECTIONS: Typically there will be a minimum of three (3) inspections required during the installation of the wastewater disposal system. These inspections will occur as follows: I. The first inspection must be conducted after the excavation of ditches, pits, trenches, or beds and before the installation of any gravel. A septic tank may be set in place, but may not be backfilled before this inspection. 2. The second inspection must be conducted after the placement of the silt barrier, gravel, distribution lines, standpipes, cleanouts, and insulation, but before the placement of any other backfill. 3. The final inspection is to occur upon final grading of the property. Often there will be more than these 3 inspections required. Especially with the installation of multiple trenches, sand filters, pressurized distribution systems, etc. Thus, the inspecting engineer is to be contacted at least 24 hours prior to the start of construction. If necessary, a pre -construction meeting will take place on-site. The inspecting engineer will not coordinate, direct or control in any way the contractors activities. The owner shall contract with the contractor to perform the work outlined in these specifications and plans and in accordance with the attached M.O.A. permit. There will be no contractual arrangement existing between the contractor and S & S Engineering. S & S Engineering shall be the owner's representative and will inspect the work as stated above to document the contractors activities. Final acceptance of the contractors work rests with the owner and the M.O.A. Page Five Lot 3B, Block 2, Donaho Homestead, Addn #1 August 27, 1996 S & S Engineering shall have no liability to the owner or to others for acts or omissions of the contractor or any other persons performing work on this project or the failure of the contractor to carry out the work in accordance with these construction documents. S & S Engineering's inspecting engineer will not be responsible for the construction means, methods, techniques, sequence, procedures or the safety precautions incident to this project. CONTRACTOR/INSTALLER Municipality of Anchorage Development Services Department Building Safety Division On -Site Water 8 Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907)343-7904 Sip CERTIFICATE OF ON-SITE SYSTEMS APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. 050-911-93 COSA# Cl1. GENERAL INFORMATION Expiration Date: If — 0 1 Complete legal description DONAHOE HOMESTEAD N 1: LOT 38, BLOCK 2 Community Class Well ❑ Public Water System Location (site address) 19339 CITATION ROAD* EAGLE RIVER AK, 99577 Current Property owner(s) Mailing address Lending agency Mailing address Real Estate Agent Mailing address GREGG do JACKIE GUNNARSON Day phone P.O. BOX 90982• ANCHORAGE AK. 99509 Day phone 762-3158 BARBARA CRITTENDEN W/ PRUDENTIAL Day phone 689-1802 16635 CENTERFIELD DRIVE, ANCHORAGE AK, 99577 Unless otherwise requested, COSA will be held by DSD for pickup. 2. NUMBER OF BEDROOMS: 4 3. TYPE OF WATER SUPPLY: Individual Well ❑ Individual Water Storage ❑ Community Class Well ❑ Public Water System 0 TYPE OF WASTEWATER DISPOSAL: Individual On-site a Individual Holding tank ❑ Community On-site ❑ Public Sewer ❑ The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certifitates of On -Site Systems Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues COSAs upon request to homeowners. Certificates of On -Site Systems Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water samples. (Certificates may be reissued for a period of up to one year with valid water samples.) C6rtificates are valid for one year for properties served by Clads A or B wells or a public water system. The Municipality of Anchorage is not respopsible for errors or omissions in the professional engineers work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, 1 verity that my. investigation,'based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate . for the number of bedrooms and type of structure indicated herein. I further verify that based on the 'information optained from the Municipality of Anchorage files and from my investigation and inspection, the on-site.watei supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. . • Name of Firm GARNESS ENGINEERING GROUP, Ltd. Phone 337-6179 Address 3701 •E. TUDOR ROAD, SUITE 101 ' ANCHORAGE, AK 99507 Engineer's Printed Name JEFFREY A. GARNESS, P.E. Date 1 D d Engineer's Comments: In conducting this evaluation, GEG, LID. attempted to provide a thorough, conscientious engineering analysis of the system in accordance with ADEC and MOA DSD Guidelines & Regulations. The reported results described the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readily Identifiable features. The operational life of all weps and septic systems depend on the local soils condition, groundwater levels that may fluctuate during the year, and the water usage of the family being served by the system. These conditions are outside the control of the evaluator of the system. Satisfactory test results do not guarantee future performance of the system, nor do they guarantee that there are no hidden defects or encroachments. GEG. LTD. can therefore not provide any warranty or future estimate of how long the system will continue to meet the operational requirements of the ADEC or MOA DSD. The content of this report Is for the sole benefit of the owner listed above. Any reliance upon or use of this report by any other person or party is not authorized, nor will it confer any legal right whatsoever. S. DSD SIGNATURE Approved for 4 bedrooms. Disapproved. Conditional approval for bedrooms, with the fllowing stipulations: Attachments: COSA Checklist Septic System Advisory Well Flow Advisory —L.�- Arsenic Advisory Maintenance Agreements Supplemental Engineers Reort Nitrate Advisory Other By:lzl'' (R".11105) Original Certificate Date: PROGRAM Municipality of Anchorage • '� Development Services Department =� Building Safety Division On -Site Water d Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST Legal Description:. _____ DONAHO HOMESTEAD #1; LOT 3B, BLOCK 2 Parcel ID: 03�o'2�>'' S� A. WELL DATA • PUBLIC WATER Well type If A, B, or C provide PWSID# _ Well Log (Y/N) Date completed Sanitary seal (Y/N)_ Wires properly protected (Y/N1 Total depth ft. Cased to ft. Casing height (ab round) in. FROM WEL;—g.p.m. AT I CTION Date of test Static water level Well production g.p.m. WATER SAMPLE RES Coliform colonies/100 ml. Nitrate mg./L. Other bacteria colonies/100 ml. Arsemug./L. Date of sample: Collected by: B. SEPTICIHOLDING TANK DATA Tank Type/Material SEPTIC/STEEL Date installed 10/5/1996 Tank size 1250 gal. Number of Compartments 2 Cleanouts (Y/N) YES Foundation cleanout (Y/N) YES Depression over tank (Y/N) NO High water alarm (Y/N) N/A Date of pumping 5/7/2008 pumper JR'S PUMPING C. ABSORPTION FIELD DATA EEow EXISTING GRADE NORTH TRENCH/SOUTH TRENCH Date installed 10/5/1996 Soil rating .p.d. or ft'/bdrm) 0_6 System type DEEP TRENCH Length 100' (2050') ft. Width 2.5/2.5 ft. Gravel below pipe 5/5 ft. •9.75/ Total depth •8.6 ft. Eff. absorption area 1000 ft= Monitoring tube YES Depression over field NO Date of adequacy test 0 *5/13/2008 . Results (Pass/Fail) PASS For 4 bedrooms Fluid depth in absorption field before test 30/21 In. Water added 9100 gal. New depth 46 33 in. Elapsed Time: 120 min. Final fluid depth 44/31 In. Absorption rate >= 600+ g.p.d. Any rejuvenation treatment (past 12 mo.) (Y/N & type) NONE KNOWN If yes, give date — "WATER INTRODUCED THROUGH DOUBLE CLEANOUTS AFTER TANK. D. LIFT STATION Date installed Size in gallons Manhole/Access "Pump on" level at in. "Pump off' I�at �r High water alarm level at in. Cycles tested Meets alarm & circuit requirements? E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: PUBLIC WATER Septic tank/lift station on lot On adjacent ,Absorption field on lot On adjacent lots Public sewer main Sewer /septic service areas manhole/cleanout Holding tank Manure/animal excrete storage areas SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 5'+ Property line 5'+ Absorption field 5'+ Water main 10'+ Water service line •10'+ Surface water 100'+ Wells on adjacent lots 100'+ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line 10'+ Building foundation 10'+ Water main 10'+ Water service line '10'+ Surface water 100'+ Driveway, parking/vehicle storage 3' Curtain drain NONE KNOWN Wells on adjacent lots 100'+ F. COMMENTS "PER S&S INSPECTION REPORT. G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. Engineer's Printed Name JEFFREY A. GARNESS Date 5/&lc>13 COSA Fee U- 00 Date of Payment t1D 28�1� Receipt Number , -4;dO (Rev. 11105) Waiver Fee $ Date of Payment Receipt Number /s " E«• � srt. EJ"yvT i?�Z'ET'T/F/G/o rlGLl/ E• �f/�6' I1QO,IIIT .r Ix 6 ASSOCIATES LP.N'D I HEREBY CERTIFY THAT I HAVE SURVEYED THE SCALE: FOLLOWING DESCRIBED PROPERTYt G %9y0 n?1. ' "l: QF A�"% R i "(� .fb•:�Yirv` iDt� <OT.fB df d AND THAT NO DATE: • ..... . •9 P; ENCROACHMENTS EXIST EXCEPT AS / INDICATED. IT IS THE RESPONSIBILITY OF THE �� r_M OWNER TO DETERMINE THE EXISTENCE OF ANY GRID: ..; • ✓••�� •'• A EASEMENTS, COVENANTS, OR RESTRICTIONS n7✓SS f ` /����; WHICH DO NOT APPEAR ON THE RECORDED SUBDI- /� • �l VISION PLAT. UNDER NO CIRCUMSTANCES SHOIl.D ANY DATA HEREON BE FB' �f os , , µ„k y,,,a / /�c ••, q�i Ar 1i.;. •• �F USED FOR CONSTRUCTION `�' OR FOR ESTABLISHING BOUND- DRAWN: DRAWN: AOF RY LINES. NES. .O�/f i?�Z'ET'T/F/G/o rlGLl/ E• �f/�6' I1QO,IIIT .r Ix 6 ASSOCIATES LP.N'D I HEREBY CERTIFY THAT I HAVE SURVEYED THE SCALE: FOLLOWING DESCRIBED PROPERTYt G %9y0 n?1. ' "l: QF A�"% R i "(� .fb•:�Yirv` iDt� <OT.fB df d AND THAT NO DATE: • ..... . •9 P; ENCROACHMENTS EXIST EXCEPT AS / INDICATED. IT IS THE RESPONSIBILITY OF THE �� r_M OWNER TO DETERMINE THE EXISTENCE OF ANY GRID: ..; • ✓••�� •'• A EASEMENTS, COVENANTS, OR RESTRICTIONS n7✓SS f ` /����; WHICH DO NOT APPEAR ON THE RECORDED SUBDI- p VISION PLAT. UNDER NO CIRCUMSTANCES SHOIl.D ANY DATA HEREON BE FB' �f os , , µ„k y,,,a / /�c ••, q�i Ar 1i.;. •• �F USED FOR CONSTRUCTION `�' OR FOR ESTABLISHING BOUND- DRAWN: DRAWN: AOF RY LINES. NES. .O�/f