Loading...
HomeMy WebLinkAboutDRAKE BLK 1 LT 2AOnsite fife #017a=461 am 24 Municipality of Anchorage Community Development Department Page 1 of 3 On -Site Water and Wastewater Program 4700 Elmore St.. P.O. Box 196650 Anchorage, AK 99519-6650 - http://www.muni.org/onsite - (907) 343-7904 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP181335 PID Number: 017-461-24 ❑ New R] Upgrade Name: Dave Harper ABSORPTION FIELD ❑ Deep Trench � Shallow Trench ❑ Bed El Mound Address P.O. Box1 10496 El Other Phone Number of Bedrooms Soil Rating Total depth from original grade 5 1.2GPD/SF1 6.5 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade 4.5 Ft. Gravel depth beneath pipe 2.0 Ft. Subdivision Block Lot Drake S.D 1 2A Fill added above original grade 0 Ft. Gravel length 55/55 FL Township Range Section Gravel width 5 Ft. Beds: Number of Lines 2 Distance between lines 10 Ft. SEPARATION DISTANCES To From Septic Tank Absorption Field Lift Station Holding Tank Sewer Line Total absorption area 785.7 Fe Number of trenches N/A Dist. between trenches N/A Ft. Well i 102.5 106 114 N/A 100+ TANK [D Septic El S.T.E.P. 0 Holding 171 Other Manufacturer Anchorage Tank Capacity 1500Gal. Surface Water 100+ 100+ 100+ c N/A — Material Number of compartments Lot Line i 66 7.2* 67 N/A NA STEEL 2 Foundation 29 37 37 i NIA — LIFT STATION Manufacturer Capacity Curtain Drain 50+ 50+ 1 50+ N/A Orenco 500 Gal. Remarks Installed per ADEC Requirements Pump on level at 40 in. Pump off level at 36 in, High water alarm at 45 in, Pump make and model P2005-1 jElectrical Inspections performed by Installer PIPE MATERIAL House totank 3034 Tank 10 3034 drainfield Beek's Construction Drainfleid 3034 CO/MT 3034 Inspector Pannone Engineering Services BENCHMARK (Assumed elevation) 1 00ft Inspection It dates: 10/3/18 2"' 10/3/18 3"' 10/4/18 4v' Location and description Top of Lift Station Riser COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL Engineer's Stamp Conditional Approval: Date OF AZ, alk '49 Pannone E 81 k 4. Approved L_Au Date _10011E, IJPtC .t I U1 I McPUI L_ 1- 1- !Z.UUU DOUBLE CLEAN OUT 0 CLEAN OUT z 0- M Z CLEAN OUT CLEAN OUT 500g LIFT STATION MAN HOLE o FLOW SPUTTER CLEAN OUT MONITOR ONITOR TUBE (2EA) MONITOR TUBE (2EA) CLEAN OUT (2EA) 0 0-- m Co C0 :;o -n 0 m T --4 M M 0 0 c: i�3 0 0 X ;:0 M < F) zz —> --q -5 > o cn z 0 = W 0Ivs — m m0 c: :1 z z Co m M ;:o C-) 0 z :E zM m IS < r - z r- m 0 U) x m c m > I P/c K to > cn -0 --4 z 5; -< -4)0 M>O ;u --- I- c 0,3 u) K C/) > ;a > cn -0 --1 z -0 , -< 0 m;o 0 m>0 ;u C) cf) m F= x Z• Lo M --i m m (.n �. —w L— m (-4 TF=xz K m (A cn > m >U >NO X _q m m M.. 0 U) 0 M 0 m > K 0 --4 x (_n > ()0 G) m r1i --j m > o.. Cp m 0 0 Ln 0 Lf) Co u m cn.- 0'- ;5 f') GUS > cn :,i m C3 ct) K,. — V) q > K to > cn -0 --4 z 5; -< -4)0 M>O ;u --- I- c 0,3 u) K C/) > ;a > cn -0 --1 z -0 , -< 0 m;o 0 m>0 ;u C) cf) m F= x Z• Lo M --i m m (.n �. —w L— m (-4 TF=xz K m (A Z -< X > ;a(/) < a 0 7 1-) --4 > Fj C m 0 > moo-li >U >NO X _q m m M.. 0 U) 0 M 0 0H M Ln M.. 0 > K 0 --4 x (_n > ()0 G) m r1i --j -n - o.. Cp m 0 0 Ln 0 Lf) Co u m cn.- 0'- ;5 f') GUS > 0 --� q 0 -� 5 - Q C/) r- M -0 — (.n :,i o-, I ;u rj ct) K,. — V) q > T1 Z> 0 0 bo V) -1 -r to fl) -TI -TI M "J cy) 0 m rtl -------- m tQ 70 K m m b m iTt x 0 rli U) cli --q 41 N)Z -,i m 0 rt m co z p0 0-0 cil 0 (-n m cf) > cn o n 0 x m 0 r ---i -,a z ;u on El. ff r- x cm '77-0 !Q 0 :E 0 FQ m M K C) K C) 12 -n I r- 10 ---1 --, n, I n 0 n m Cl --j J0) 0) 00 p W0) -P, 41 41 U, cil (p U U CO 4 :-1 CO CO 0 CD 0 cl, 0 > N 0 m cn o 0) cn ('4 o (-n -j 0) 0) 11 -4 41 -? 0) 0) -P 41 (A cli L4 0) --4 A 0 CO (JI(0 CO N) co co Cj co 0) o N) 6) ^J cj cli -lj I I NOTES: PANNONE ENG SVC LLC RECORD DRAWING P.O. BOX 102954 ANCHORAGE, AK 99510 PHONE (907) 272-8218 FAX (907) 272-8211 DRAKE 131 2A DRAWN ACP DAVID & PATRICIA HARPER 2700 HUFFMAN ROAD SITE PLAN ANCHORAGE, AK w TH even anrioee CE 8149 ....... REVISIONS VAIL 09/07/2018 REV l.: 9/20/2018 SCALE 1" = 50' REV 2: 9/20/2018 REVS: 10/04/2018P.J.0. NO 017-461-24 PERMIT NO Ospxxxxxx SHEET 1 OF 2 > > N -co - > < -0 m Z z -11 m rTl m 0 0 > -< z (f) 0---I — m z m 00 > m —0 Ln rtl -------- z p0 0-0 cil 0 (-n m cf) > cn o n 0 x m 0 r ---i -,a z ;u on El. ff r- x cm '77-0 !Q 0 :E 0 FQ m M K C) K C) 12 -n I r- 10 ---1 --, n, I n 0 n m Cl --j J0) 0) 00 p W0) -P, 41 41 U, cil (p U U CO 4 :-1 CO CO 0 CD 0 cl, 0 > N 0 m cn o 0) cn ('4 o (-n -j 0) 0) 11 -4 41 -? 0) 0) -P 41 (A cli L4 0) --4 A 0 CO (JI(0 CO N) co co Cj co 0) o N) 6) ^J cj cli -lj I I NOTES: PANNONE ENG SVC LLC RECORD DRAWING P.O. BOX 102954 ANCHORAGE, AK 99510 PHONE (907) 272-8218 FAX (907) 272-8211 DRAKE 131 2A DRAWN ACP DAVID & PATRICIA HARPER 2700 HUFFMAN ROAD SITE PLAN ANCHORAGE, AK w TH even anrioee CE 8149 ....... REVISIONS VAIL 09/07/2018 REV l.: 9/20/2018 SCALE 1" = 50' REV 2: 9/20/2018 REVS: 10/04/2018P.J.0. NO 017-461-24 PERMIT NO Ospxxxxxx SHEET 1 OF 2 L; Ll CA -1 C. �0> , n t' 'o 7- n �' � 8 . . . I . . . w 0 Z: 0 ... 0 z z 0 M > 0 M W C) > K > T Z;o W 0 M �3 T 0 M Z = X 5x>mw- �M>MoHmm-mo-=>S�ZTX�xz- Ln > > -0 2 0 � C;, K 100- >OM�2<-OZ�CF�m=fnn'>7 < ;0 0;00'000"� 0 > - >OnmMmon�nonn>nx n➢0,0> - D;um miz�'- 0 Z: 0 (A 0 -zm&ipum;ucmmz < O;u�>>Hm C 0 > I < X -0 M 5 � > n;u 0 m z z 0 C 0 0 - 0' �mo 0 a m 0::j z 0 ;0m > m Zm'n* nz;uzz� !Z>. 5 X K X ;0 0 On --Q M � =' ?�m 00 Z liti m 0 OO'<Zo 0 > Z 'a Z ;u M;u K 5 mo z -:j j-05< >=> >Cx:'0OO > > ::E > W Qz�w'-< z z z 0D m z c: , -0 0 K > Ar C -m -MAS; Z20 Oozm;o X::� M '> C, OE- Z0200-9 m no 7'KW ZMMF C3 M�c8K,>HH'Mmmoo>=� m 01 CSU zx- m�' 0�0_ Urn , T z -0 m > , > - 'u MG.'m-'o-o C 9 M M -T ->-' 9< 0 z 2 > 22 0 :0 r) 0 GU z �z - x -': - 0 c) n >M> M�A x ? K -x , 0 r> z v 'zxo —UK > -0 z a > E0 z LI) - z > u) M 6T� FA a ;u z 0 Qmp C7 � E, >MMM3 -4 �0->m -imcn M >T L" z M� Q -�->5 w Z 0 =j ;M0 z m' c: > > ;u 5 'z7 m F o C) K 2;0 F -0 now 2-8pp > W Go- 0 0 0 K - M 5� 0 0 M z -Wq 3: 0 :c z 0 0 -V E5 �ZOOOZ5 0 K S W M Far Z Z Z a � n > c" z > > nm > z > 2 > , 'ms5z*c>)�' 26 Oz 5 0 g F �, (ll,-qGG> z cj.-rw�yp > OM 0 gym" om !0 c . , 0 1 Is > c) 0 -(no-- z C70 , -0 ➢a X 0 M z ILI m -0 ,i AOS I' 2'02M I m , mm mm, o- m > To, r>>M2* rA-�Mo- x z > �W5 (A > mo- OM50<m mr 2 7z > m 0 -500�00 Zmx z m— Z-0 M- w Z z � -4 mW 0, > ml 01- ';u Z: < W m 0 Z 0 m 0 q:5 -'b a 0z: 12) 0, 5 mm, 0 imp T> p S. wx TI m-m M>K58 > mm5W >m0>8s-0>-9 z w Z 0 z z mm WM S ox - >z mv, 2MQ �0 -0 xm co x OW > m -OZ >a- I � A, T-00" npm�m U) m 0 E-5 Q 0 gq s z a -0 2� n d 0 N z z ma* -mo < F, ""< - �:;o z > o'L" o 0 0 0 -0 OEZC- �> ;0 < M m >>K Ozo> -0 VZ M Ez lz -< s; E-im 0'2> ?, 0 K z x >' M, Mv zw> I m T M nz Mon m WOE ZZK - > O'u W 50 m 00" •> rn:C '2s -.6o ?U > �- '< ma - I mll 2 >' OM > 000�� P M mz W ax m ;uz OoC Z;Z�' m g�: z m -Z z �� - i� on w � K M O'> OMT -q "5-0 M z L, a) 0 'zQ M 0 ->4 > z m 0pmym , m 5 > M;0 > 0 ;Q 0;0 a,:j ;o C) > n :c AM m Zc z Ll M a: > 00 -0m- �E CM) > mK < K m 2 " 0- mu 2 >z > ul >M-000 < > M z K M, M0 z 5->4i z 0 < M x ?PM A o p m 0 ,, W� - ��am c- -<OOM 6 M' n m 'm Z �3� 5 n W, 6mm ?ZO -'J'C 0 ;u m* M > 2 - 0 p 0 0 MM 7- 0, m w E U) m m mz 05' c' z m WOmF' 0 � M�' (:) M (A > w E-< mom > o -;0 col x < >' > z -< TI m 3: 00 mo Z mm> > M G N, A O< 2 m>O Cm am z 'Z' 0 0 ('n m oz Oc)- Zo >Mz' -mo Owz z * m ?Om 0 0 0 M w r, > < m Im- m S� C C '0 0 0 Z>d ➢zm' W ZO e5 M, 0 a 0 2'W' m' m , ;0 2 CO 0 Z 0 0 OK Mw ->IEF m o2m x 0 -< c O� L' CA C , = �: � 0 i;i x z (nom > m M, R m V �> m - z Z:2m- m w C W <80 ;am In, A.- 0 E -* 0, o' r- Z M;u > mnm -0 W > 0 Mp WZ� 0 U, IA -2Mg -;, I > 0 -<0 < M- E m- >M o > 's nuo Mz W > M a L< In 2 no-- um mm, 'v G m, mz m, , >z >zz>mo AK 2 u-, -> 0-- gi�i z >ZK M -0 Mm 0 ! C W Z> M 0 -�w Mzl zyn z -Go C > ':' > -QMK z z jam m m ;0 M 58 > >> > M Om ma �E m m M -K Oz n > < mooc-< (A -< 0 ;-2, M W 0 , -0 5 m :m t; ��O z Z 2 M Zoo -Z' M' Z M M W 01 CM, IZ I Mo> o z 0' > So> 0 '-Eo > > , 1:1 O'G 0 < > 5 a?:� ' Z' WZO OF, Z 'm -Z-1 0 OM M, z K 0 -< > To> m Z> 2 0 >0� K -m W W < Ol r-MMM5 z 0 C m S? -v * -u * ZS W 0 pT'i D7 Zip pa -c 0 > �0 ;,u 'pm >p mm z A -1 z MID- -0 7 -mc WM z 0 0 m>O c OX =-<�"�5m 0 xM >' Z ADZ 0 x I 0 m 5!z- M 0 > PC , ;lu X m 0 E n < Zw 0 a 0 z � H * Z 0 C Z: m < C n- a: m 0 W a O>' > = �; (n =� W mm 0 o z m Z;c m I :!;;u 0 F 0M 2Z 2: C 3> 0 M > m 0 > '0 Om C C z Z z z n C) x (� c: m C m W moz z > (A 0 ril I i I i i i I i I I a I ;0 10 m O NO M0 > 0 m > M- < 0 -< CD OKO o m z Oto 0 M 0 >om n Z > -Z a 'I -0W A z m Wm ;0 z z;u W � Z > -o 200 w, I mc ;u * X Z 2 M z > 1 0 r- d -H > I > --4 z m 0 r < > m 0 o>M ;u z r) z r) SOD > < r') Z cr 0 O>Z �� z 0 Oenm rn - 0 W (A W;:DK M rl > - - - om TO z �;o M p '+ z c� > --i = 1 Cz Cz R-0. z M m mo E5m m o' U) z w — — — — 0 m > I A <>< -ff ;>O? 1� 1 1% > 2<mm" z zrnz-, M> V) ;u c > - 2>: u L Z > Ooz V) W Cl <ZO 05 00 U > > NOTES: PANNONE ENG SVC LLC REVISIONS DATE FOR CONSTRUCTION P.O. BOX 102954 ANCHORAGE, K 99510 09/07/2018 PHONE (907) 272-8218 FAX (907 272-8211 REV 1: 9/20/2018 SCALE .*j 1 50' DRAKE Bl L2A P.I.D. NO DRAWN ACP DAVID & PATRICIA HARPER tlevlaw' Fpa* no.,;e 017-461-24 SHOEPxxxxxx SOILSLOG & 27N ROAD It ANCHORAGET NOTES 2 OF 2 TESTHOLE LOG Legal Description: DRAKE B1 L2A Inspected By: Steven R. Pannone, P.E. Ground level ift _T iTesthole Location Map 3ft Oft 5ft 6ft 7ft 9ft 1 Oft lift 1 2ft 13ft 14ft 1 5ft I 6ft 17ft I 8ft 19ft Total Depth of Testhole 14 ft. Date: 7/15/2006 Comments: Soils poorly grade3d gravel to silty gravel... Suitable for an on-site disposal field ... Use 250 sf/br Groundwater/Seeps Encountered? Y /9 At N/A ft. Impermeable Soil (Silt/Clay/Bedrock) Encountered? Y /a At N/A ft. Form revised 2/2016 / / HUFFMAN ROAD . \ |SED � \-32; �rt,4 �2 MANHOLE �r� i�f �� �wx 10' UTILITY EASEMENTS CHAIN—LINK FENCE N 9700'00lY 155.00' ' Lof 8 Lot 7A Lof 78 PLOT PLAN AS BUILT _2�_ SCALE 1. 50' GRID �2834 Project No. 18-169/A2 11500 Daryl Avenue, Anchorage, Alaska 99515-3049 Lang & Associates, inc. (907) 522-6476 Phone (907) 522-4625 Fox OF 4, Professional Land Surveyors kenOlangsurvey.com b, 1 hereby certify that I have surveyed the following described prope fA� LOT 2A, BLOCK 1, DRAKE SUBDIVISION (PLAT No. 71-313) Anchorage Recording District, Alaska, and that the Improvements situated thereon are ...... within the property lines and do not encroach onto the property adjacent thereto, that no improvements on the property lying adjacent thereto encroach on the surveyed .... ............... jd�&XW LANG promises and that there are no roadways, transmission lines or other visible A rn Q easements on sold property except as Indicated hereon. LS 994 Day z Dated this of Anchorage 4:7 the of Alas K Is the the owner to determine the existence of any mnnto, ~nre�vDs�� co,onomm, or restrictions which do not appear on the recorded subdivision plot. A[CC863 "°f:'! 0, MUNICIPALITY OF ANCHORAGE On-Site Water&Wastewater Program PO Box 196650 4700 Elmore Road Anchorage,Alaska 99519-6650 Phone:(907)343-7904 Fax:(907)343-7997 \ / http://www.muni.org/onsite Ih•partnicnt �hCHOP p'� On-Site Wastewater Disposal System Permit Permit Number: OSP181335 Effective Date: 9/21/2018 Work Type: Septic Upgrade Expiration Date: 9/21/2019 Tax Code Number: 01746124000 Site Legal Address: DRAKE BLK 1 LT 2A G:2834 Site Mailing Address: 2700 HUFFMAN RD, Anchorage Owner: HARPER DAVID & PATRICIA Lot Size in Sq Ft: 46200 Design Engineer: PANNONE ENGINEERING SERVICES Total Bedrooms: 5 This permit is for the construction of: ❑ Disposal Field Q Septic Tank ❑ Holding Tank 0 Privy 0 Private Well 0 Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing • Received By: , CAdd& - Date: "//P"7//g Date: / / Issued By: �► , q �� �� RoSflI EPLANS MUNICIPALITY OF ANCHORAGE ------"---" Community Development Department Phone: 907-343-7904 Development Services Division - Fax: 907-343-7997 On-Site Water&Wastewater Program ON-SITE SEWER/WELL PERMIT APPLICATION Parcel I.D. 017-461-24 Property owner(s) David & Patricia Harper Day phone Mailing address P.O Box 110496 Anchorage, AK 99511 Site address 2700 Huffman Road Anchorage, AK Legal description(Sub'd., Block& Lot) Drake B1 L2A Legal description(Township, Range &Section) Lot Size 46,200 Sq. Ft. Number of Bedrooms 5 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (E)all that apply) Absorption Field ❑ Initial ❑ Single Family(SF) ❑X (w/wo ADU) Septic Tank ❑x Upgrade ❑x Duplex (D) ❑ Holding Tank ❑ Renewal ❑ Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE/WAIVER REQUEST FOR: Dis tance: I certify that the above • ormation •: corre I further certify that this is in accordance with applicable Municip. Codes. / ,, "Al (Si• - ur- •t operty owner or 7111Mc, atit6'4e - /-ale . UV �" 'V'' " S�Sae RllSF Permit/Rush Fees: Qtb.'t Waiver Fees: Date of Payment: Q J I'4(I O Date of Payment: Receipt Number: 0 Logt Receipt Number: Permit No. ns p 111335 Waiver No. Permit App_.:-'• Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPIJANCE Pannone Engineering Services LLC OSP181335.Deb VVockenfuss,09/21/18 Steven R. Pannone, Principal Registered Professional Engineer E-mail:steve@panengak.com September 7, 2018 Subject: Drake B1 L2A Tank Replace Permit Request Design Narrative This is a design narrative for a permit to install an upgrade 1,500g Septic Tank to replace an existing 1,000g Septic tank to be issued for this property. The existing tank is too small to service the existing 5 bedroom house, It will be decommissioned per code. Currently the lot is developed. The proposed 1,500g septic tank will be connected to the existing lift station. The existing tank is located outside of the 100' protective well radius. The proposed tank will be placed outside the 100' protective well radius. 1. Upgrade Tank Design. A foundation clean out installed if needed. The tank will be located: 5'+from any property line 10'+from building foundation 10'+from any water line 100'+from any surface water 100'+from any private wells 200'+from any public wells 2. Existing Drain Field. The existing septic system was installed in June of 2006 by Beeks Excavation under ADEC guidelines. It was documented by Pannone Engineering Service on 8/22/2018 and 9/3/2018.The attached drawings show the dimensions and location of the septic system. The proposed installation will not affect the future development of the surrounding or existing lots. If you have any questions or concerns, please contact me at 907.745.8200. Sinc Steven R. Pa none, P.E. Owner/Civil Engineer DESIGN PARAMETERS aD a PRIMARY SEPTIC SYSTEM ROAD "'r o o N x N NO. BEDROOM: 5(750 gpd) / HUFFMAN 0 =X o TANK SIZE: 1500g Z PERC RATE: 1.7 MPI 1OUth Emit j rj ., > g �� Wo SOIL RATING: 1.2 GPD SF "•� �; �'' -05 In IL y AREA RQD: 625 SF A° >! '- 0 8 RF: 0.70 lr� N N ,, DRIVEWAY 2 f �',: \ ADJUSTED AREA: 437.5 I 0 % 2A I --`�� . = N N SYS. TYPE: WIDE TRENCH 2.0'ED WE! I (E) (/ jrrn MIN LENGTH: 88.0 LF .. a / USED: I B3 DR cc ce I A B El > >LLI u.1 (2EA)55.OLFx5.0'Wx2.0' E.D, 5.0' TO' - E DCO 8.2 18.7 TOTAL AREA: 785.75 SF I 10'.5 B5 I T1 32.8 27.5 p.4,. �.d RESERVE SEPTIC SYSTEM �° BDR CO 43.5 35.0M 0�, NO. BEDROOM: 5(750 gpd) (P) / LS 50.5 40.6 cW • TANK SIZE: 1500gADVANTEX ' / W e I REMOVE SEPTIC TANK CO FS 50.1 44.2 �'• �I�� PERC RATE: 1.7 MPI V 1 I PER MOA CODE I Cl 50.0 67.0 �6.• . SOIL RATING: 6.0 GPD/SF \ 23. . • AREA RQD: 125 SF \5 0 ai .DCO �'• INSTALL 1500q SEPTIC M 1 48.3 66.6 `' SYS. TYPE: WIDE TENCH 2.0'ED 271.2 1V 5.5 �� TANK (P) W/ DCO AFTER I M2 47.6 41.1 MIN LENGTH: 18.0 LF TONEU. �� I ° C2 64.0 78.3 M1 �r ��.� LIFT STATI N E M3 63.5 77.8(NIC) C1i1�=:\ SEE NOTE 1IM4 70.0 67.2 __ w - w WATER LINE/ ' J , /(1116‘ WELL 70.0 21.1 Cy W WELL RADIUS M3 -- M (..lin I -ss ss NEW SEPTIC C2 FLS.• SPLITTER (� jl^ Q Q ABBREVIATIONS TH-1 M4 DRAIN FIELD E VL$ Q = D_ Q TH TEST HOLE C' N � 2EA) 55LF x 5.0 W x 2.0 ED, S.OTD. y< Q (P) PROPOSED �Q��� / COY U < 0 (E) EXISTING /`'�,Q I RESERVE AREA BASED I ZzpO m Q CO CLEAN OUT NO. FC FOUNDATION CLEANOUT V ON CAT III (NIC) Wsct Y < 0 FS FLOW SPLITTER Z�� Q d _ MT MONITOR TUBE N0. I �° I Oo`" = U TYP TYPICAL M -� M WELL (E)/ ZX o Q NOTE 1:VERIFY SEPARATION OF. LIFT \ iltw N STATION TO FIELD AT 5 FEET. MOVEiTA CI NIC FOR TANK UPGRADE DESIGN AS NECESSARY TO ACHIEVE REytUIRED I d'aL Q N PARAMETERS ARE FOR EXISTING SYSTEM SEPARATION. I �/ DOCUMENTATION. ! ` 0 W • o 0 55 - eM_1O0 0 : m� Z OO O. D- �� O W8 p K8 OU V U V 4 Z FILTER FABRIC ELEV. 98.0 - . -DRAIN ROCK 6"ABOVE PIPE INV 2 L5 Z -IELEV. 97.5 THOLE 1 0 [L Z I e•DRAIN PIPE F 4.0 '- U < Q // - 3- W CL I000g SEPTIC TANK(E) Vl ---- _ 93.4 1000g UPGRADE TO 15008 \ 2•DRAIN ROCK Z Z SEPTIC TANK(P) ..ZZ 7 _ o.�r�soNau V I- lI- PROFILE 9111 55.0 I� o SCALE: NTS AP/20.• p NIC FOR TANK UPGRADE - PROFILE IS FOR EXISTING SYSTEM DOCUMENTATION u "TER ANCHORAGE AREA, BOROrJGH Depmlmeni ofE',~v:b:onmcn~M C~uc,:J.~.yG' ~ATER ANCHORAGE AREA BORC ~H ~800 T;~do~ lloyd -- poud~ ~ ~d HEALTH DEPART~T . ~uuu:, 327 EAQ~ ~. ANCHORAGE; A~$~ ~50!;: ~ 27~251:1 Anchorage, Alaska INspECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM N.o 999 MAILING ADDRESS :' / ~ ~ - /~ ~M~. PHONE LEGAL DESCRIPTION ~ s+;~ ~- ~~ ~~ --~'~ SEPTIC TANK: DISTANCE FROM WELL ~' NUMBER OF ~b~-~ MATERIAL / -~---~:~"'~ '-- COMPARTMENTS ~ INSIDE LENGTH INSIDE WIDTH ~ DEPTH LIQUID CAPACITY /~'-) .z/) ~/-2 GALLONS. SEEPAGE SYSTEM: SEEPAGE PIT: NUMBER OF PITS / OUTSIDE DIAMETER ~ OR WIDTH LINING MATERIAL~?:¢~/~'- d~c/~.r, ~/~/--2' (~ ""D'ISTANCE FR~M WELL //~ , LENGTH /~-C~) , DEPTH , BUILDING FOUNDATION NEAREST LOT LINE '. TOTAL EFFECTIVE ABSORPTION AREA (WALL AREA) ~?/~'~/~' ~' SQ. FT. TILE DRAIN FIELD: DISTANCE FROM WELL NUMBER OF LINES ABSORPlIO ~~~' DEPTH: TOP OF TILE TO FINISH GRADE FOUND,.~(3N , NEAREST LOT LINE DISTANCE BETWEEN LINES ENCH WIDTH SQ. FT. LENGTH OF EACH LINE ~ WELL: ~''/''k~'~'~/- -~-~.~';/-~:-~ ~'~:~>~'~. T Y P F_,,~'-~-/~,~¢/,~'~/i- .'~, DEPTH :/'// LOT LINE ~-~ , NEAREST SEPTIC SEWER LINE /~ ~-' ,TANK TOTAL LENGTH OF LINES IN. TOTAL EFFECTIVE DEPTH OF FILTER MATERIAL BENEATH TILE IN. ABOVE TILE DISTANCE FROM BUILDING FOUNDATION ,../~.~4'~ / SEEPAGE SYSTEM ,-/-~') WATER SAMPLE ./t~:- , NEAREST OTHER .-/--;//J--'¢/~- ~ , CESSPOOL r-ff/-~/(-'~-~-~ SOURCES-~-).¢; DISTANCES: DIAGRAM OF SYSTEM DATE APPROVED. ~~Y~L~TH~OR~T~'~'~'~'~''~'' ~ ' /'Cz Greater ANCHORAGE AREA BOROUGh DEPARTMENT OP' ENVIRONMENTAL, QUALITY 3500 TUDOR ROAD POUCH 6-650 ANCHORAGE, ALASKA 99502 TELEPHONe 279-8(i86 SEWAGE DISPOSAL SYSTEM APPLICATION AND PERMIT INSTALLATION Of: SEPTIC TANK SEEPAGE PIT DRAIN FIELD OTHER tYPE aND SIZE Of faCilitY TO be SErVEd ~~~/ SOIL TEST .ESULTS ¢¢~~/~ NOTE, THIS PERMIT IS NOT VALID WITHOUT SOIL TEST FINAL INSPECTION: 24 HOUR NOTICE REQUIRED. BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION BY THE HEALTH DEPARTMENT AUTHORITY WILL BE SUBJECT TO PROSECUTION. MINIMUM DISTANCES, REQUIREMENTS FOUNDATION TO SEPTIC TANK ' ~ // FOUNDATION TO SEEPAGE PIT '~ ~/ /' . DRAIN FIELD SEPTIC TANK TO SEEPAGE Pit WALl /~'~ / SEPTIC TANK ~'--/ SEEPAGE Pit ~/D / , DRAIN FIELB. TO NEAREST LOT LINE. WELL TO SEPTIC TANK '~ ~" , SEEPAGE PIT DRAIN FIELD ALSO CONSIDER AREA WELLS. WATER main TO SEPTIC TANK ?/~/ , SEEPAGE Pit DRAIN FIELD DIAGRAM OF' SYSTEM TO RIVER, LAKE, STREAM. CAST IRON INTO AND OUT OF SEPTIC TANK AND INTO CRib CROSSING GAP OF EXCAVATION 5 FEET INTO UNDISTURBED SOIL. 4 INCH DIAMETER CAST IRON SIPHON PIPES ON SEPTIC TANK AnD SEEPAGE PIT fITTED WITH AIRTIGHT REMOVABLE CAPS. GRAVEL BACKFILL CONFORM TO BOROUGh REGULATIONS REGARDING INSTALLATION. LICENSED DESIGNER I CERTIFY THAT I Am FAMILiar WITH THE REQUIREMENTS OF GREATER aNCHORAGE ARea BOROUGH ORDINANCE NO, 28-68 AND THAT THE ABOVE DESCRIBED SYSTEM iS IN ACCORDANCE WITH SAID CODE. G" Al'ER ANCHURAGE AREA BOROU[ DEP rMENT OF ENVIRONMENTAL QUA~ i'¥ 3500 TUDOR ROAD ANCHORAGE, ALASKA 99502 CASE Performed For Hills Excavating Legal Description: Lot_~_~Block This Form Reports Soils Log Date Performed.. 11/29/71 Subdivision Drake Perc~i ation Test Depth Feet Soil Characteristics 3~ 4-- 5- m Brown silty fine sand (SM) Gray well graded samds and gravel (OW) Was Ground Water Encountered? no If Yes, At What Depth? Reading Date Gross Time ! Net Time i Depth to H20 Net Drop Percol a'ti"on Rate Minute Proposed Installation: Seepage Pit x Drain Field Depth Of Inlet Depth To Bottom Of Pit Or Trench COMMENTS: 85 s~uare feet of drainaBe area is required Bet bedroom with the crib set 3.5' to 9,,'5'.'/ 'This material may be used a~ backfill except for the upper 3.5' yest" Performed By R. E. Cariisl~ ' "Da'la Cer'{'ified BY:National Testing Svs. Inc. Date: • • TUE U ® .� Municipality of Anchorage On-Site Water and Wastewater Program < (907) 343-7904 ®� Certificate of On-Site Systems Approval • c Parcel I.D. 017-461-24 Expiration Date: JCL.fl 1 0 o� 01 l 1. GENERAL INFORMATION Complete legal description Drake Block 1 Lot 2A Location (site address) 2700 Huffman Rd. Current Property owner(s) David & Patricia Harper Day phone Mailing address PO Box 110496 Anchorage, AK 99511 Real Estate Agent Day phone 2. TYPE OF DWELLING: Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 5 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well Q Individual Individual Water Storage ❑ Holding Tank ❑ Community Class Well ❑ Community ❑ Public Water System ❑ Public Sewer ❑ WaiverNariance request for: Distance: • Received by: Date: l %'l07 COSA to be released to the engineer,unless otherwise requested by the engineer. COSA Fee $ 5 i*- 315, 0t b`�1.60 Waiver Fee $ Date of Payment $0.<6\\% Date of Payment Receipt Number Receipt Number COSA# C j\`"\3L, Waiver# 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are)in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. In conducting an adequacy test,I attempt to provide a thorough,conscientious engineering analysis of the system in accordance with MoA COSA guidelines and regulations.The reported results describe the performance of the system under the conditions encountered at the time of the test. and separation distances measured to readily identifiable features. The operational life of all wells and septic systems depend on the local soil condition,ground water levels that may fluctuate during the year,and the water usage of the family being served by the system.These conditions are outside the control of the evaluator of this system. All systems eventually fail and satisfactory test results do not guarantee future performance of the system,nor do they guarantee that there are no hidden defects or encroachments.Therefore we cannot provide any warranty for future performance, nor can we estimate remaining life of the system. The content of this report is for the sole benefit of the owner listed above. Name of Firm Pannone Engineering Services LLC Phone (907) 745-8200 Address P.O. Box 1807 Palmer, AK 99645 Engineer's Printed Name Steven R Pannone, P.E. Date 10/5/18 ��a®�cv.v0 ®g • 1 •y �A 011*: 49 0 6. DSD SIGNATURE ••• ••• 'Ir• System #1 Approved for f�~ y pp 5 bedrooms S/even R. .annone CE-8149 System #2 Approved for bedrooms ����s•. • Disapproved )1�PRp• FESSjONA\- Conditional approval for bedrooms, with the following stipulations: (JO \i ��/I • /it ro ON-SITE �, WATER AND `r' WASTEWATER z c`c PROGRAM � off.- • !LIcMSCR\J\C By: JJ .v.,0, ROriginal Certificate Date: 10/ 10 0 S The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On-Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA blue sheet_S - • If more than 1 septic system is on the lot: COSA Checklist# 1 of 1 Structure served by this system I Certificate of On-Site Systems Approval Checklist Legal Description: Drake Block 1 Lot 2A Parcel ID: 017-461-24 A. WELL DATA Well type Private If A, B, or C provide PWSID# Well Log (Y/N) N Date completed UNK Sanitary seal (Y/N) Y Wires properly protected (Y/N) Y Total depth 86 ft. Cased to 86 ft. Casing height(above ground) 12+ in. FROM WELL LOG AT INSPECTION ' Date of test UNK 8/8/2018 Static water level UNK ft 2 ft. Well production UNK g P m 10+ g.p.m. WATER SAMPLE RESULTS: Coliform NEC' colonies/100 mL Nitrate 0.231 mg/L Arsenic ND D ug/L Date of sample: 8/8/2018 Collected by: Aarow Pump&Well Services B. SEPTIC/HOLDING TANK DATA Tank Type/Material Septic/Steel Date installed 10/3/2018 Tank size 1500 gal. Number of Compartments 2 Cleanouts (Y/N) Y Foundation cleanout (Y/N) Y Depression over tank (Y/N) N High water alarm (Y/N) Y Date of pumping Pumper New C. ABSORPTION FIELD DATA Date installed 7/20/2006 Soil rating (g.p.d./ft2 or ft2/bdrm) 250 SF/BDRM System type Shallow Trench Length 55/55 ft. Width 5.0/5.0 ft. Gravel below pipe 2.0/2.0 ft. Total depth 6.5 ft. Eff. absorption area 785.7 ft2 Monitoring tube Y Depression over field N Date of adequacy test 9/22/2018 Results (Pass/Fail) PASS For 5 bedrooms Fluid depth in absorption field before test 0/0 in.. Water added 750 gal. New depth 0/0 in. Elapsed Time: 120 min. Final fluid depth 0/0 in. Absorption rate >= 750+ g.p.d. Any rejuvenation treatment (past 12 mo.) (Y/N & type) N If yes, give date D. LIFT STATION Date installed 7/20/06 Size in gallons 500 Manhole/Access (Y/N) yes "Pump on" level at in. "Pump off' level at in. High water alarm level at in. Datum Cycles tested Meets alarm &circuit requirements? E. SEPARATION DISTANCES WELL ON LOT TO: Septic tank/lift station on lot 100+ On adjacent lots 100+ Absorption field on lot 100+ On adjacent lots 100+ Public sewer main 75+ Public sewer manhole/cleanout 100+ Sewer/septic service line 25+ Holding tank 100+ Animal containment areas 50+ Manure/animal excrete storage areas 100+ SEPTIC/HOLDING TANK ON LOT TO: Building foundation 10+ Property line 10+ Absorption field 5+ Water main 10+ Water service line 10+ Surface water 100+ Wells on adjacent lots 100+ ABSORPTION FIELD ON LOT TO: Property line 7.2 Building foundation 10+ Water main 10+ Water Service line 10+ Surface water 100+ Driveway, parking/vehicle storage 10+ Curtain drain 50+ Wells on adjacent lots 100+ F. COMMENTS Drainfield pre-soaked with 2000gaI clean water per code. - -z . - -: ; .•- . _• . . G. ENGINEER'S CERTIFICATION .���eo�a� I certify that I have determined through field inspections and ,r:'\'� 1 •� } review of Municipal records that the above systems are in j•k A '. P. %N, %.*?4 conformance with MOA COSA guidelines in effect on this date. ®•• . ve• • ••••• 0 v '� Engineer's Printed Name Steven R. Pannone, P.E. i .S{even R. Pannone • 0 10/5/18 -' CE-8149 �&% Date ¢t 9s• 'i? / I ( cc-;'-rte 0-1e2,4,co•1,V�.n)� s, ����••. • �i � �� �OFESSIONP COSA canary sheet_2-6-15.doc