HomeMy WebLinkAboutDRAKE BLK 1 LT 4brake
Block 1
Lot 4
#017-461-20
On -Site Wastewater Disposal System Permit
MUNICIPALITY OF ANCHORAGE
Development Services Department
On -Site Water & Wastewater Program
4700 Elmore Road, PO Box 196650
Anchorage, AK 99519-6650
Telephone: (907) 343-7904
Permit Number: OSP151343
Tax Code Number: 01746120000
Work Type: Septic Upgrade
Permit Effective Dates: October 19, 2015 to October 18, 2016
Design Engineer: GARNESS ENGINEERING GROUP LTD
Subdivision: DRAKE
Site Legal Address: DRAKE BLK 1 LT 4 G:2834
Owner/Address: BYRD DAVID L & SUE S
2900 EAST HUFFMAN ROAD ANCHORAGE AK 995162017
Site Mailing Address: 2900 HUFFMAN RD, Anchorage
This permit is for the construction of:
Y Disposal Field Y Septic Tank N Holding Tank N Privy
All construction must be in accordance with:
Lot Size in Sq Ft: 83807
Total Bedrooms: 3
N Private Well N Water Storage
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater
Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80).
3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services
Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either:
A. Open and Close on the same day.
B. Covered, sealed, and heated to prevent freezing.
Received B)
Issued By:
C'oI itfv,us 4t 4�.�c4k-v�k.
MUNICIPALITY OF ANCHORAGE
Community Development Department Phone: 907-343-7904
Development Services Fax: 907- 343-7997
On -Site Water & Wastewater Program —: m.
Mayor Dan Sullivan �UL„ y;
On -Site Sewer/Well Permit Application
OCT 08 2015
For A Single Family Dwelling Gretchen Stuller
Parcel I.D. 017-461-20
Property owner(s) DAVID BYRD Day phone 563-0491
Mailing address 2900 HUFFMAN *ANCHORAGE, AK
Site address 2900 HUFFMAN *ANCHORAGE AK
Legal description (Sub'd, Block & Lot ) DRAKE BLOCK 1, LOT 4
Legal description (Township, Section & Range)
Lot Size
Sq.Ft. Number of Bedrooms
3
APPLICATION IS FOR:
APPLICATION IS AN:
TYPE OF DEWELLING:
(gall that apply)
Initial ❑
Single Family (SF)
Absorption Field
®
N
(w/wo ADU)
Septic TankDuplex
Upgrade
❑
(D)
El
Holding Tank
❑
Renewal
Multiple Dwellings
❑
Privy
❑
(SF and/or D)
Private Well
❑
Water Storage
❑
THIS APPLICATION INCLUDES A VARIANCE/ WAIVER REQUEST FOR:
Distance: —
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal codes.
GARNESS ENGINEERING GROUP, Ltd.
(Signature of property owner or authorized agent)
Permit/Rush Fees:
Date of Payment:
Receipt Number:
Permit No.
Waiver Fees:
Date of Payment:
Receipt Number:
Waiver No
(Rev. 01/11)
GARNESS ENGINEERING GROUP, Ltd
CIVIL & ENVIRONMENTAL ENGINEERS
October 2, 2015
Municipality of Anchorage
Development Service Department
On -Site Water & Wastewater Program
4700 Elmore Road
Anchorage, AK 99507
Ref: Proposed Septic System for Drake; Block 1, Lot 4 cot
RL
To whom it may concern: taco ���4-
The existing 3 bedroom holatate
served by private well and septic system. The
existing septic system is in of failure and needs to b upgraded. We are
proposing to install a newgallon and >�tiallow trench type
drainfields. One testhole was excavated on the property and the drainfield is designed
within the 30 foot radius. Comments regarding the design are summarized as follows:
1. SOILS: See the attached 2015 log which show the soil classifications, groundwater
monitoring, and the percolation test results. We are also requesting a variance to allow
for the utilization of in-situ soils for a sand filter, please see soil sample submitted with
design.
2. DRAINFIELD DESIGN: See attached design drawing for drainfield specifications.
3. SURFACE WATERS: There are no surface water concerns.
4. TOPOGRAPHY: See attached 40 scale which shows topography information.
We are unaware of any adverse impacts this installation would have on adjacent wells
or septic systems. If you have any questions, please contact us at 337-6179. Thank
you for your assistance.
_., M.S.
3701 East Tudor Road, Suite 101 * Anchorage, Alaska 99507-1259
Phone: (907) 337-6179 * Fax: (907) 338-3246 * Website: www.garnessengineering.com
DEVONSHIRE #1; TRACT A
\ �REA
pPPROX�IUS 1 \
WELL
T12N R3W SEC 21 E2SE4SW4SW4
\ _ — — /
THOMAS L BOYLE;
BLOCK 2, LOT 10
I
/ \ �---_-_---_--- ---�_—
HUFFMAN ROAD
AaP
Mrs— /
I
WELL ' , � I
IDRAKE;14LOCK k, \
/ 1
.y„ LOCATION PER MOA RECORD'.
100' WELL RADIU
,;+ I WELL COULD NOT BE FOUND
DURING SITE VISIT—
DRAKE; BLOCK
1, LOT 3B
I
I
I
I PROPOSED [
_—__----_ — — — — — — _PER 2014 A
DRAKE; BLOCK 1, LOT 6 DRAKE; BLOCK 1, LOT 5
�REA
PTIC
EA I WE L X11
�I
FiLLI•
DRAKE; BLOCK 2, LOT 1
GARNESS ENGINEERING GROUP, Ltd
CIVIL & ENVIRONMENTAL ENGINEERS
..w,u...1 . a.Ox6 IM71 vi-filn • Fm fWn 339-32M • WE89TE:�.aainvsow wRnO
PREPARED FOR: I PHONE NUMBER: PACE NUMBER:
CINDY LOVELACE (GUARDIAN) (9 07 563-0491 1 OF 2
LEGAL DESCRIPTION: DRAWN BY:
DRAKE; BLOCK 1, LOT 4 D.J.G.
TYPE OF WORK: DATE:
SITE PLAN 10/5/2015
* * 1_1. 111mrj_*
'°ROFESS1(:tti
I
z
w
6
NUMBER OF BEDROOMS: 3 LETTER THAT PERTAINS TO THIS DESIGN.
GALLONS PER DAY (GPD): 450 TO OBTAIN A COPY OF THE LETTER
PERCOLATION RATE/S: <IMIN/INCH CONTACT GEG. BY PROCEEDING FORWARD
PROPOSED APPLICATION RATE: 1.0 WITH THIS INSTALLATION, THE ENGINEER, H U H H M I/n\
� N ROAD
WELL DRILLER, CONTRACTOR AND
MINIMUM GRAINFIELD SQ.FT.: 450 FT' PROPERTY OWNER AGREE THAT THEY
HAVE READ THESE SPECIFICATIONS AND
AGREE TO ACCEPT THE TERMS AND.
�r,..��r. r. �,-.•._ CONDITIONS OUTLINED. 10' UTILITY EASEMENT
MAXIMUM DEPTH OF EXCAVATION: 10 FEET
WIDTH: 5.0 FEET
LENGTH: 45 FEET \
M.O.A. APPROVED SAND FILTER: PROPOSED
USING INSITU SOILS AS SAND FILTER
EFFECTIVE: 4 FEET
REDUCTION FACTOR: 0.5
ACTUAL SQ.FT.: 450 FT'
NOTE: THE CONTRACTOR
SHALL HAVE THE WELL RADII
FLAGGED BY A REGISTERED •`'
LAND SURVEYOR PRIOR TO .•DRIVEwA ••
CONSTRUCTION.
1
wao ow a
100' WELL RADIUS °
1 1/
1
\ ` EXISTING 3 BEDROOM
HOUSE i
_a
� � DECK PR
\_ 5�
\ INSTALL FCO
EXISTING SEPTIC TANK TO BE
DECOMMISSIONED PER UPC
ASSUMED PERIMETER OFG
PIPE SEEPAGE PIT BASED UPON PIPE
LOCATION
SEEPAGE PIT CLEANOUT
i /-7
`11
Cal
/�"E`� a f1- x t�afi'�n
ED i69b'QALrt6N
�A"
DOUBLE CLEANOUTS
THE TANK
I DRAINFIELD
h!
hfER
INSTALL DIVERTER VALVE SO THAT FLOW
MAY BE DIVERTED BETWEEN EXISTING
SEEPAGE PIT AND PROPOSED TRENCH
10' UTILITY EASEMENT
GARNESS ENGINEERING GROUP,Ltd
CIVIL & ENVIRONMENTAL ENGINEERS =
3701 E. TUWR RO , SUITE 101
PREPARED FOR:
DAVID BYRD
DRAKE; BLOCK 1, LOT 4
TYPE OF WORK:
, SEPTIC SYSTEM DESIGN UPGRADE
6179 ' IM (907) 330-3246 r KESITE:—.9ornn n9�n
PHONE NUMBER: PAGE NUMBER:
(907)563-0491 2 of 2
DRAWN BY:
D.J.G.
DATE:
10/19/
5 1 •,,�,taassw
0
GARNESS ENGINEERING GROUP, Ltd
CIVIL & ENVIRONMENTAL ENGINEERS -
3]1 E TUDOR ROAD. SUITE 101•ANCifOAE, M 99507• PHONE (907) 33110in-FM(907)31S 46'N£BSITE:i—gameawnq eMp.wm
LEGAL DESCRIPTION: DRAKE; BLOCK 1, LOT
PERFORMED FOR: DAVID BYRD DATE: 9/22/2015
DEPTH
(feet) ORG TEST HOLE #1
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
SP
0amwolW311-1IaLN_11Lou6i
SM % : OH
SC
DEPTH TO
GROUNDWATER
DATE
DRY
9/22/2015
•'
9/30/2015
Y41T
i//ii
SM % : OH
SC
DEPTH TO
GROUNDWATER
DATE
DRY
9/22/2015
DRY
9/30/2015
LDATE READING I CLOCK I NET TIME I WATER LEVEL I NET DROP
TIME (MINUTES) READING (INCHES)
9/25/2015 1 ABSORBED 5 GALLONS OF WATER IN LESS THAN 2 MINUETS 2 TIMES
s PERCOLATION RATE <1 (MIN./INCH) PERC. HOLE DIA. 6 (INCHES)
TEST RUN BETWEEN 5.5 FT. AND 6.5 FT.
20 A FOUR HOUR PRESOAK WAS PERFORMED: ❑ YES NO
SOILS LOGGED BY: ROB CAMPBELL PERCOLATION TEST PERFORMED BY: ERIKWIDGER
COMMENTS: PERCOLATION READINGS ARE WITHIN 1/16 OF INCH.
PERFORMED BY GEG, Ltd. I, JEFFREY A. GARNESS, CERTIFY THAT THIS WAS PERFDR ED IN ACCORDANCE
WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: i0 i /
GRE" 'ER ANCHORAGE AREA BOP AGH
Department of Environmental Quality
3330 C Street
Anchorage, Alaska 99503
INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM
NAME G% Zf�-1 MAILING ADDRESS / % --1V L" 1iPHONEr%_ °` �''
LOCATION //�lF/ _'�: 1 «! Y� .<< f?� . j ✓ /yam' ' �i /moi':
��' %.'' LEGAL DESCRIPTION
SEPTIC TANK:
DISTANCEjyi NUMBER OF
FROM WELL lam; MANUFACTURERS -rte ��-MATERIALi'� i'�'^
__COMPARTMENTS
INSIDE LENGTH INSIDE WIDTH LIQUID DEPTH LIQUID CAPACITY /��'��J GALLONS.
SEEPAGE PIT:
NUMBER OF PITS . DIAMETER OR WIDTH LENGTH Z2, DEPTH -�
LINING MATERIAL CRIB SIZE: DIAMETER DEPTH DISTANCE FROM: WELL
X TOTAL EFFECTIVE
BUILDING FOUNDATION-:� , NEAREST LOT LINE �/� ABSORPTION AREA (WALL AREA) SQ. FT.
ADDITIONAL ABSORPTION
777 7'
WELL: �G'T �'��" � /T /��./�.> /•'�li.T/✓✓/- � �'G/��%- / ,� ����!//,✓//�%o!'%,'/��/�l�.c+' ��%�i�✓✓-',.,jt,%ice_-/
%-'�'�+°'t> .:3"e✓'a�"�`.�..ix.c t/i`'./✓:;/•�v Ge ?r. �%` <`:' . <-.:tee^ rx-' .
TYPE ✓/��✓✓r/.��'ii/r CONSTRUCTION/]/�� DEPTH 4 } DISTANCE FROM:
BUILDING NEAREST NEAREST SEPTIC,._/$-'� SEEPAGE���''
FOUNDATION, LOT LINE �� SEWER LINE - , ` , TANK -1 SYSTEM
CESS POO L�J//� OTHER SOURCES
APPROVED DISAPPROVED �'REMARKSf�
LOT SLOPE:
REMARKS.
Form No. EQ -031
DIAGRAM OF SYSTEM
DISTANCES:
INSTALLED BY:
PIPE MATERIAL:
LOT SLOPE:
REMARKS.
Form No. EQ -031
DIAGRAM OF SYSTEM
DATE �%APPROVED 'ter/Y
G.A.A.B.
rA
�I
T
,`
Wig, [--�
K�! •r.-.. i
�t
DATE �%APPROVED 'ter/Y
G.A.A.B.
GREATER ANCHORAGE AREA BOROUGH
a`T DEPARTMENT OF ENVIRONMENTAL QUALITY PERMIT NO
3330 "C" STREET ANCHORAGE, ALASKA 99503
TELEPHONE 274-4561
t0
SEWAGE DISPOSAL SYSTEM - APPLICATION AND PERMIT
NAME OF APPLICANT vZe e— MAILING ADDRESS A01" `�/ U �`-"� PHONE
J �17'
INSTALLATION LOCATION l a7r-
LEGAL DESCRIPTION e C/ lef
INSTALLATION OF: SEPTIC TANK SEEPAGE PIT DRAIN FIELD OTHER ,
TYPE AND SIZE OF FACILITY TO BE SERVED
FINANCED THROUGH
TO BE INSTALLED BY
SOIL TEST RESULTS +� NOTE: THIS PERMIT IS NOT VALID WITHOUT SOIL TEST
COMPLETION DATE ANTICIPATED /�1j`/ ,
FINAL INSPECTION: 24 HOUR NOTICE REQUIRED. BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION BY THE
DEPARTMENT OF ENVIRONMENTAL QUALITY AUTHORITY WILL BE SUBJECT TO PROSECUTION.
SEPTIC TANK SIZE TYPE-I:Jvrt�.... SEEPAGE AREA SIZE
MINIMUM DISTANCES, REQUIREMENTS
FOUNDATION TO SEPTIC TANK
FOUNDATION TO SEEPAGE PIT DRAIN FIELD
SEPTIC TANK TO SEEPAGE PIT WALL 4J
SEPTIC TANK .5 , SEEPAGE PIT , DRAIN FIELD
TO NEAREST LOT LINE.
WELL TO SEPTIC TANK % SEEPAGE PIT
DRAIN FIELD ALSO CONSIDER AREA WELLS.
WATER MAIN TO SEPTIC TANK SEEPAGE PIT
DRAIN FIELD /,p
SEPTIC TANK, ` /, SEEPAGE PIT _ DRAIN FIELD
TO RIVER, LAKE, STREAM.
CAST IRON INTO AND OUT OF SEPTIC TANK AND INTO CRIB CROSSING GAP OF�
EXCAVATION 5 FEET INTO UNDISTURBED SOIL.
4 INCH DIAMETER CAST IRON SIPHON PIPES ON SEPTIC TANK AND SEEPAGE PIT
FITTED WITH AIRTIGHT REMOVABLE CAPS. \�
GRAVEL BACKFILL V�
CONFORM TO BOROUGH REGULATIONS REGARDING INSTALLATION.
G.A.A.B.
OR
LICENSED DESIGNER
1 CERTIFY THAT I AM FAMILIAR WITH THE REQUIREMENTS OF GREATER
DESCRIBED SYSTEM IS IN ACCORDANCE WITH SAID CODE.
DATE C2! -; j� APPLICANT'S SIGNATURE
FORM NO. EQ -016
2 W400104=
DIAGRAM OF SYSTEM
E AREA BOROUGH ORDINANCE NO. 28.68 AND THAT THE ABOVE
GREATER ANCHORAGE AREA BOROUGH
DEPARTMENT OF ENVIRONMENTAL QUALITY Case #
3330 "C" Street
ANCHORAGE, ALASKA 99503
J?? Dated Performed /� 7�
Performed For G��; ,ice, _ '
Legal Description: Loth Block Subdivision,h..r�la k_
This Form Reports Soils Log_( Percolation Test
- Soil Test Must Be Logged To 4' Below Proposed Seepage System -
Depth
Feet Soil Characteristics
I-
2-
3-
4-
5-
6-
7-
8-
--
3-
4-
5-6-7-8-
9—
9—
Was
Was Ground Water Encountered? 11
If Yes, At What Depth?
Reading Date Gross Time Net Time Depth to H2O Net Drop
Percolation Rate Minute
Proposed Installation: Seepage Pit Drain Field
Depth of Inlet Depth to Bottom of Pit or TrencFi�—
COMMENTS:
Test Performed BY
Date Certified BY:
Date: