Loading...
HomeMy WebLinkAboutDRAKE BLK 3 LT 7 SREA,_R ANCHORASE AREA BOR Department of Environmental Quality 3500 Tudor Road Anchorage, Alaska 99507 GH INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM MAILING ADDRESS ~//~ /-~///'~L~AL DESCRIPTION ~/~/~- PHONE SEPTIC TANK: DISTANCE FROM WELL INSIDE LENGTH MANUFACTURER '~/~'~"-~' "~'"'~'<~' MATERIAL NUMBER OF COMPARTMENTS INSIDE WIDTH. LIQUID DEPTH .LIQUID CAPACITY /~ GALLONS. SEEPAGE PIT: NUMBER OF PITS / DIAMETER____ OR WIDTH ~5~, / LENGTH'~,~/DEPTH ~ LINING MATERIAL / ~Z:~ ~/~/~IB SIZE: DIAMETER DEPTH .~/DISTANCE FROM: WELL BUILDING FOUNDATION /V/~-/'~/ NEAREST LOT LINE ~,~7 / TOTAL EFFECTIVE ABSORPTION AREA (WALL AREA) '~'~ / .SQ. FT. ADDITIONAL ABSORPTION WELL: TYPE BUILDING FOUNDATION CESSPOOL ~/~ APPROVED CONSTRUCTION~ DEPTH DISTANCE FROM: NEAREST /.. NEAREST , LOT LINE ~ ~' , SEWER LINE , OTHER SOURCES ~-~ / DISAPPROVED REMARKS SEPTIC / SEEPAGE TANK /~' , SYSTEM /~'~ /-/- . DISTANCES: ! INSTALLED BY: ~g~C'Z,.¢' PIPE MATERIAL: ~/'~--~'~/ LOT SLOPE: REMARKS: Form PW-026 DIAGRAM OF SYSTEM ,l G.A.A.B. DATE GREATEr ANCHORAGe ArEA BoruOGh DEPARTMENT OF ENVIRONMENTAL QUALITY 3500 TUDOR ROAD POUCH 6-65'0 ANCHORAGE, ALASKA 99502 TELEPHONE 279-8686 SEWAGE DISPOSAL SYSTEM -- APPLICATION AND PERMIT PERM,T NO, 2147 INSTALLATION OF: SEPTIC TANK SEEPAGE PIT DRAIN FIELD OTHER TYPE AND SIZE OF FACILITY TO BE SERVED,, ~ ~~ ,~'~1.0 ~ ~ ; ~ FINANCED THROUGH TO BE INSTALLED BY BOIL TEST REBULTS NOTE= THIS PERMIT IS NOT VALID WITHOUT SOIL TEST COMPLETION DATE ANTICIPATED~._~/~ FINAL INSPECTION= 24 HOUR NOTICE REQUIRED. BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION BY THE HEALTH DEPARTMENT AUTHORITY WILL BE SUBJECT TO PROSECUTION, MINIMUM DISTANCES, REQUIREMENTS FOUNDATION TO SEPTIC TANK I ~ FOUNDATION TO SEEPAGE PIT _. 2~: ~ SEPTIC TaNK TO SEEPAGE Pit WaLL SEPTIC tANK ~ ' 2~ , SEEPAGE Pit TO NEAREST lot LINE. / WELL TO SEPTIC TANK . DRAIN FIELD WATER MAIN TO SEPTIC TANK I''/~~ DRAIN fIELD BEPTIC TANK, ., SEEPAGE PIT f~ TO RIVER, LAKE, STREAM. , DRAIN FIELD ., DRAIN FIELD ., DRAIN FIELD AREA SIZE TYPE DIAGRAM OF SYSTEM CAST IRON INTO AND OUT OF SEPTIC TANK AND INTO CRIB CROSSING GAP OF EXCAVATION ]6 FEET INTO UNDISTURBED SOIL. 4 INCH DIAMETER CAST IRON SIPHON PIPEB ON SEPTIC TANK AND SEEPAGE PIT FITTED WITH AIRTIGHT REMOVABLE CAPS. GRAVEL BACKFILL CONFORM TO BOROUGH REGULATIONS REGARDING INBTALLATION. LICENSED DESIGNER I CERTIFY THAT I AM FAMILIAR WITH THE REQUIREMeNTB OF GREATER ANCHORAG~A BOROUGH ORDINANCE NO. 28.68 AND THAT THE ABOVE G~EATER ANCHnRAGE AREA BOROU, . DEPARTMENT OF ENVIRONMENTAL QUALITY 3500 TUDOR ROAD ANCHORAGE, ALASKA 99502 CASE # Performed For6'havlm Salem ,,, Legal Description: Lot ? Block 3 This Form Re~orts Soils Log X Date Performed ,~1o~1~ Subdivision Drake Percolation Test De~th Feet Soil Characteristics SP poorly graded sand -- (150) 7-- ,, 9__ Was Ground Water Encountered? I~ Yes, At what Depth? Readin.q Date Gross Time Net Time Depth to H20 Net Drop Percolation Rate Minute Proposed Installation: Seepage Pit x Drain Field Demth of Inlet DeDth To Bottom Of Pit Or Trench C 0 M ~ E N T S · SP in upper 12 t. of, t~st hole: SM below in last_2/~.][t sq. per bedroom needed. Test Performed Data Certified By: Date ·