Loading...
HomeMy WebLinkAboutDELUCIA LT 40 ' Municipality of Anchorage Page DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744 On-Site Wastewater Disposal System and/or Well Inspection Report Permit Number: ~/ ~/dO~"/~--~ PID Number: 0~/- /&/'/ Name: ~/~b~ Wastewater System: ~New D Upgrade Address: ~9 DAW/~ ~. ~ ABSORPTION FIELD Phone: I No. o~rooms: ~ ~ ~ ~~ ~p Trench a Shallow Trench a B~ a Mound a Other Total Depth from original grad~: LEGAL DESCRIPTION so,,R.~,.~: j. ~ ~PD/s~.~. /~,~' Lot: ~O Block: ~~ ~/~Subdivision: Depth to pi~ ~ffom~/fmm ~°riginal gr~e: Ft. Gravel depth beneath~,pipe~ Ft. · o..,,,= ,s~IR..,.: /~ I,--,,on=/ Filladd. above original grade: Gravellength: Gmvel~ Number of lines: IDistance ~n lines: WELL: ~New ~ Upgrade ~/~H ~ ~. ./ I Cl~ifi~tion (P~ate. A.B.C): - To~l ~pth: Ca~ To: Total absorption area: Pipe material: ~'*'~: ~'~ ~.~ ~t.I '~/7- ~ ~t. ~" TANK SEPARATION DISTANCES ~.pt~ a Ho,~,.~ a TO ~ ~m~ U~ ~ldl~ ~P~ Manufa~ure~ . Capaci~ in~ Material: Number of Compa~ments: Sudace · w.~.~ ~/pO ~ LIFT STATION Em / / ~ Li.e /D 5 71 Size in gallons: Manufactur*~ Cu~ainDmin ~ ~ ~ ~ ~~~1 Insp~tions pedorm~ by: Remarks: E~;~ ~x ~~ ~= ~. ~;,~. BENCH MARK Lo.lion and Description:  Assum~ Elevation: /00, ~0 ~,. .... ENmNSE~'S SEAL Inspections pedormed by: ~ ~ Dates: Ist )~/~/~. ,g~~"7".'"~~.~ ~~' ''~ ~ '"" ..... ;.' ... 2nd/o/~/~~~-. ........ ~. ~, , CE.6736 . Dep..ment Hea uman e.i e..pprova ".,- ..... ' ..... Reviewed and approved by: Date: /2-2 7-~- 72-013 (1/91) MOA 25 Permit No. sw940427 Page 2 of 2 Municipality of Anchorage DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 34-3-47zi-4 On-Site Wastewater Disposal System and/or Well Inspection Report Legal Description: DELUC;IA LOT 40 PID No.: 051-141-11 z LBT 39 A 89°59'0' E 105,80 TRENCH -+- -- MONITOR WELL · - MONITOR TUBE o - SEWER CLEANOUT + - WELL ~ - LEACHFIELD SWING TIES A-C = 38.1 B-C = 69.7 A-D = 64.7 B-D = 47.1 ELEVATIBNS (NFIT T8 SCALE) FINISH ELEV 99,1 CORNER DF BLDCK FDUNDATIDN ASSUHED ELEV = 100,00 FINISH ELEV 99.4 INgULATION ORIGINAL GROUND LEVEL AT~ SCALE 1"-40' 10-31-95 ND GWT 79,7 ENGINEER'S SEAL ~6~X LOUIS A. BUTER~'YE~ Louis Butera. ?.E. Registered Civil Engineer May 22, 1995 lim Cross, P.E. Manager, On-Site Services Municipality of Anchorage P.O. Box 196650 Anchorage, AK 99519 Re: Delucia, Lot 40 Dear Mr. Cross: Subsequent to our meeting at your office, our client, Mr. Arvid Miller, has decided to drill a new private well in the location shown on our revised plan. This location is 100' distance from all documented septic systems, and the owner of Lot 39 has stated there is not a septic system on his lot. We have to rely on his verbal statement given to Mr. Miller as there are no records for his dwelling, and the lot has so many storage buildings and general auto parts, that it can not be completely visually inspected. Our new site plan allows us to place (he septic in its original location, utilizing the 5' lot line waiver applied for in our March 1995 permit application. The wastewater system specifications and design remain the same. The existing well will be abandoned by the following procedure: 2. 3. 4. 5. 6, Remove pump and pipe Cut off casing four feet below ground level Fill welt with clean gravel and sand to a level of 10 feet below top of casing FiLl final 10 feet with Bentonite grout mix Weld 0.25 inch cap over top of casing Backfill hole If you have any questions please call our office at 694-5195. Sincerely, Louis Butera, P.E. Arvid Miller, Owner/Applicant \C:\WPV~N 60\~,VPDO CS\ 1995\94-085C.NAR Arvid Miller 6701 E. 10th Avenue Anchorage, AK 99504 November 7_.6?, 1995 To Eagle River Engineering Services: I am the legal owner of Delucia, Lot 40, and I have abandoned the old well located on the east side of the house using the method described in the letter of May 22, 1995 to Mr. lira Cross of the Municipality of Anchorage. Arvid Miller \G:\WPDOCS\ 1995\94-085B. LTR Rick Mystrom, Mayor Municipality of Anchorage Department of Health and Human Services 825 "L" Street P.O. Box 196650 Anchorage, Alaska 99519-6650 343-4744 November 13, 1995 Arvid & Wanneta Miller 6701 East 10th Avenue Anchorage, Alaska 99504 1813 Subject: Lot 40 Delucia Subdivision Permit %SW940427, PID %051-141-11 The subject permit, issued November 7, 1994 by this office for a single family well and/or on-site wastewater system, has expired as of November 7, 1995. A new permit must be obtained from this office for a well and/or on-site wastewater system NOT installed by the expiration date. If you have drilled the well, a well log must be sent to this office for documentation of the installation and to close the permit. If a licensed Professional Engineer has inspected the installation of the on-site wastewater system, the original as-built inspection report must be sent to this office for review, approval and documentation. All inspection reports must be submitted within 30 days of construction completion. When applying for a new permit, the fees are: $320.00 for an on-site wastewater permit; $120.00 for a well permit and $440.00 for a combined on-site wastewater and well permit. If you have any questions, please call this office at 343-4744. j~r_oe 1 y, .7 PFogram M~a~nJger On-site Services enc: Copy of Permit cc: Eagle River Engineering Services PAGE 1 OF 1 5gJNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND HUMAN SERVICES P.O. BOX 196650, 825 "L" STREET, ROOM 502 ANCHORAGE, ALASKA 99519-6650 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT PERMIT NUMBER:SW940427 DESIGN ENGINEER:CONSTRUCTING ENGINEERS, INC. OWNER NAME:MILLER ARVID & WANNETA OWNER ADDRESS:22839 DANIEL CT CHUGIAK, ALASKA 99567 DATE ISSUED:Il/07/94 EXPIRATION DATE:il/07/95 PARCEL ID:05114111 LEGAL DESCRIPTION: DELUCIA LT 40 LOT SIZE: 15682 (SQ. FT.) NUMBER OF BEDROOMS: 3 THIS PERMIT: THIS PERMIT IS FOR THE CONTRUCTION OF: DISPOSAL FIELD /SEPTIC TANK SYSTEM ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH: 1. THE ATTACHED APPROVED DESIGN. 2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS 15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80). 3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY CALLING 343-4744 (24 HOURS) 4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING WEATHER MUST BE EITHER: A. OPENED AND CLOSED ON THE SAME DAY B. COVERED, SEALED AND HEATED TO PREVENT FREEZING 5. THE FOLLOWING SPECIAL PROVISIONS. SPECIAL PROVISIONS: DATE: Louis Butera, P.E. Registered Civil Engineer May 22, 1995 Jim Cross, P.E. Manager, On-Site Services Municipality of Anchorage P.O. Box 196650 Anchorage, AK 99519 Re: Delucia, Lot 40 Dear Mr. Cross: Subsequent to our meeting at your office, our client, Mr. Arvid Miller, has decided to drill a new private well in the location shown on our revised plan. This location is 100' distance from all documented septic systems, and the owner of Lot 39 has stated there is not a septic system on his lot. We have to rely on his verbal statement given to Mr. Miller as there are no records for his dwelling, and the lot has so many storage buildings and general auto parts, that it can not be completely visually inspected. Our new site plan allows us to place the septic in its original location, utilizing the 5' lot line waiver applied for in our March 1995 permit application. The wastewater system specifications and design remain the same. The existing well will be abandoned by the following procedure: 2. 3. 4. 5. 6. Remove pump and pipe Cut off casing four feet below ground level Fill well with clean gravel and sand to a level of 10 feet below top of casing Fill final 10 feet with Bentonite grout mix Weld 0.25 inch cap over top of casing Backfill hole If you have any questions please call our office at 694-5195. Sincerely, Louis Butera, P.E. Arvid Miller, Owner/Applicant \C:\WPWIN60\WPDOCS\1995\94-085C.NAR P.O. Box 773294 · Eagle River, Alaska 99577 · Telephone (907) 694-5195 · Fax (907} 694-3297 Louis Butera, P.E. Registered Civil Engineer March 7, 1995 Jim Cross, P.E. Manager, On-Site Services Municipality of Anchorage P.O. Box 196650 Anchorage, AK 99519 Re: Delucia, Lot 40 Narrative & Permit Application Dear Mr. Cross: On behalf of our client, Mr. Arvid Miller, we are requesting re-issue of the septic permit for the property referenced above. The original permit, number 93-0400, application was provided by Constructing Engineers. Minor modifications in the layout and total depth have been made, based on our site evaluation. A new test hole was excavated to 18' and a monitor tube was installed. We were unable to verify the recorded total depth and water table in the original test hole, possibly due to a blocked monitor tube. A new percolation test was not accomplished as it was determined by your office that the signature on the original percolation test and soil log was valid. A site plan showing the location of the both test holes and the proposed layout is attached. Due to the small size of the lot and the existing well location, a waiver and variance of separation distances are requested. The design requires a variance of the normal 50' horizontal separation distance from the field to a downslope cutbank. The gravel cutbank has a 10'-15' vertical drop at a slope of 90-100%. The variance required will be 35' from our replacement site to the cutbank. A waiver of the normal 10' separation distance from field to lot line, to 5', will also be required. The lot contains an existing well which was installed under permit number 88-0165. During our investigation, it was determined that there is an undocumented septic system on neighboring Lot 36 that is 76'-87' from the subject well that was not noted on the original site plan. If you have any questions please call our office at 694-5195. Sincerely, Louis Butera, P.E. RECEIVED MAR 0 ? 1995 Ni,.,~, ,;.~my of Anchorage Dept. Health & Human Servicee \C:\WPWlN60\WPDOCS\1995\94-O85A.NAR P.O. Box 773294 · Eagle River, Alaska 99577 · Telephone {907) 694-5195 · Fax (907) 694-3297 LBT 4 LDT 4,::' NO SEPTIC AS PER BWNER NEW WEL Z LDT 39 SEPTIC 8O 3x22 REPL. 3'x;~2' TRENCH CD SEPTIC LOT 38 LBT 37 NO SURFACE WATER NO KNOWN CURTAIN DRAINS ORIGINAL PERMIT #SW95-0440 SEPTIC SITE PLAN LEGAL: LOT 40 DELUCIA OWNER' MILLER (v.4.) CONTRACTOR: N/A JOB :// 94-085 DATE' WLVlSLL) , 1" 05/22/95 ! SCALE = 40' EAGLE RIVER ENGINEERING SERWCES A P.O. Box 773294 EAGLE RIVER, AK. 99577 (90?') 694-5195 FAX: (907) 694-3297 LFIT 36 EXIST, WELL TB BE ABANDDNED WELL +zoo' -~ - MONITOR WELL · - MONITOR TUBE o - SEWER CLEANOUT 4h - WELL , , - PROPOSED LEACHFIELD ELEVATIONS (NOT TO SCALE) 86.7 ORIGINAL GROUNI) LEVEL AT, TR1 98.7 TH2 98,7 --I m LO -H 0 m Nlq G~/T 80.6 PROFILE LEGAL: LOT 40 DELUCIA OWNER-ARVID MILLER CONTRACTOR: N/A JOB # 94-085 DATE. 11/18/94 SCALE NTS EAGLE RIVER ENGINEERING A P.O. Box 773294 EAGLE RIVER, AK. 99577 (907) 694-5195 FAX: (907) SER WCES 694-3297 SPECIYICATIONS FOR ON-SITE SEPTIC SYSTEM LEGAL: A. Delucia Lot 40 1. The septic plan is for a single family residence only. 2. The drawing and or site plan shall be a part of this specification. 3. All materials and workmanship shall meet the Anchorage Department of Health requirements. 4. All soil tests are advisory to the design and are to be verified or modified in the field by the engineer. 5. All excavations and depths are advisory and are to be verified in the field by the contractor to meet Municipality of Anchorage requirements. 6. It is the responsibility of the owner to obtain all necessary permits or easements and to locate any adjacent multi-family wells. 7. The excavation is to be exactly in the area shown on the site plan, any deviation requires engineer approval. 8. It is always recommended that a surveyor locate the nearest lot line position and the location of any easements. 1. Tank shall be an MOA approved two compartment septic tank, a minimum of 1,000 gallons in capacity. 2. Tank shall be installed level. 1. The trench is to follow the natural land contour to maintain uniform total depth of the trench bottom. 2. The bottom of the trench shall be level, plus or minus 1.5". 3. The total depth of the trench excavation is not to exceed 12' at any point. 4. The leach line is to be laid level, total variance not to exceed 0.03'. 5. The trench gravel is to be covered with typar fabric material. 6. Soil or combination of soil and extruded board insulation to a depth of 3' or equivalent is to be placed over the leachfield. 7. The area over the trench is to be finish graded to prevent ponding of surface water runoff. 8. The septic tank and leachfield must not be closer than 100' to any existing private well, 150' to any Class "C" well, or 200 feet to any community well. RECOMMENDED I.EACHFIELD DIMENSIONS: TOTAL DEPTH = 12' GRAVEL DEPTH = 8.5' under pipe, 2" over pipe, 9' total TRENCH LENGTH = 22 TRENCH WIDTH = 3' SOIL RATING = 1.2 GPD/ft2 BEDROOM CAPACITY = 3 SEPTIC TANK = 1,000 gallons Twenty-four (24) hours notice required for all inspections. C:\WPWIN60\WPDOCS\1995\94-085A.$PC EAGLE RIVER ENGINEERING SERVICES P.O. Box 773294 EAGLE RIVER, AK 99577 (907) 694-5195 JOB SHEET NO.. CALCULATED BY CHECKED BY SCALE OF. 3 Bedro6m 5iilgl~' Family R~iden~c Application rate = use prior percolation rate from Constructing Engineers Percrate= 3'min/inch;usel:2"~ft2 : ............. .......... i ......... ~ ! ....... i ! ....... ! ........... i ................ : ...... .......... : ~ 450 gpd +.. L2 .=. 375 ftZ:requiredarea : ........ ..... :~ ........... use a" ~'=imfim ti~~ depth Of 12 ", "~tti"'SjS" Of rock .......... .......... i ................ (375)..+.. (2 x 8;5) = · 22.0, length ........................ ....... ; ........................... :~ TrCnchi dimensions: : ~ ......... :: .......... : ......... ! ....... i ....... ~figth .......... ~ 22,0' ........ i ........ ! ............. ; ...... : ............ : .......... .............................. ..... Width ....... : ...... =' 3:0: ........ : ........ ; ............... i ...... : ......... ; ....................... : .......... ¢ ................ . ........ ! ......... i ............... : ..... i ; iGraveldePth .8.5~ ................. .................... i ............ ............. i ............. 7 ...................... i ! ...... i ................ : Louis A: Butera CE-6736 \C :\WPWIN60\WPDOGS\ 1995\94-085A.CAL PERFORMED FOR: LEGAL DESCRIPTION: Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST Township, Range, Section: 1 2 3 4 5 6 7 8 9 lO 11 12 13 SLOPE SITE PLAN WAS GROUND WATER ENCOUNTERED? S L IF YES, AT WHAT O DEPTH? P E Depth to Water After Monitoring? 14 15 16 17 18 19 20 Gross Net Depth to Net Reading Date Time Time Water Drop o 10-S-OlD - - ~," _ - , / ~~ ~,~ ~ lO ~d' I"'.. ~ / o ,. ~ ~ ~ ~ I ~ ~/1~" ~/~ '.' ' ~ ~¢ .... ~,- ~ I~" I '~" COMMENTS ~ i~J..~.~, L ~ PERFORMED BY: ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. PERCOLATION RATE ~ (minutes/tach) PERC HOLE DIAMETER ~:::~" TEST RUN BETWEEN . °~ FTAND ~ FT CERTIFY THAT THIS TEST WAS PERFORMED IN DATE: 72-008 (Rev. 4/85) PERFORMED FOR: LEGAL DESCRIPTION: Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST Township, Range, Section: '5',E' ~".y 1'"/~/~ ,~/u/ ..~,~ ? 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18. 19 2O WAS GROUND WATER ENCOUNTERED? S L IF YES, AT WHAT O DEPTH? p SLOPE SITE PLAN Depth to Water Alter Monilo~ing? ,~4~'.,f /~' Date: A N Gross Net Depth to Net Reading Date Time Time Water Drop PERCOLATION RATE /~'~/~ (mlnuteshnch) PERC HOLE DIAMETER TEST RUN BETWEEN __ FT AND __ FT PERFORMED BY: ACCORDANCE WITH ALL STATE AND MUNICIPAL GUiDELiNES IN EFFECT ON THIS DATE. 72-008 (Rev. 4/85) CERTIFY THAT THIS TEST WAS PERFORMED IN DATE: ::7~'~ PAGE 1 OF MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND HUMAN SERVICES P.O. BOX 196650, 825 "L" STREET, ROOM 502 ANCHORAGE, ALASKA 99519-6650 ON-SITE WELL SYSTEM (UPGRADE) PERMIT PERMIT NUMBER:SW950097 DESIGN ENGINEER:EAGLE RIVER ENGINEERING SERVICES OWNER NAME:MILLER ARVID & WANNETA OWNER ADDRESS:22839 DANIEL CT CHUGIAK, ALASKA 99567 DATE ISSUED: 5/31/95 EXPIRATION DATE: 5/31/96 PARCEL ID:05114111 LEGAL DESCRIPTION: DELUCIA LT 40 LOT SIZE: 15682 (SQ. FT.) NUMBER OF BEDROOMS: 3 THIS PERMIT: 3 THIS PERMIT IS FOR THE CONTRUCTION OF: WELL SYSTEM ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH: 1. THE ATTACHED APPROVED DESIGN. 2. ALL REQUIREMENTS SPECIFIED IN ANCHOR31GE MUNICIPAL CODE CHAPTERS 15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80). 3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY CALLING 343-4744 ( 24 HOURS ) (NOT REQUIRED FOR WELL ONLY PERMIT) 4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING WEATHER MUST BE EITHER: A. OPENED AND CLOSED ON THE SAME DAY B. COVERED, SEALED AND HEATED TO PREVENT FREEZING 5. THE FOLLOWING SPECIAL PROVISIONS. SPECIAL PROVISIONS: RECEIVED BY: ISSUED BY: ~~/~- DATE: 9 !~0V~1~199~ 9 Municipality o! Anchorage Dept· Health & Human Servic~ P.01 May 4, 1995 Jim Cross, P.E. Manager, On-Sitc Sczvices Municipfdity of Anchorage P.O. Box 196650 .Anchorage, AK 99519 RECEIVED MAY 4 1995 Mu,,c,ij~jiI¥ o[ Anchora, Dept. Health & Human se~g/ceea Re: Dalucia, Lot ~ Dear Mr. Cross: I atiempted ~o de~'mine m~xe 0~. on the encroaching s~ic system on Lot 36 that we discussed yesterday.. The lot has a fence around it with a sign, "Protected by shotgun 3 nites a week you guess which hires." So, I didn't enter the property. Curt was able to enter it last year and took the field notes by which our septic location area was determined. He also contacted the owner for velification of location and the estimated date of construction was 1972. These are attached. As discuasod, please let us know if we can submit a waiver application for this well as a possible If you have any questions please call our office at 694-5195. Sincerely, Louis Butera, P.E. post-It' brand lax IC:\WPWIN~\~\1995\94-085B.NAR P,O, ~ 773294 · Eagle Ri~, lhsh 99577 · Tdephone ~7} 694-5195 · F~ (90/) 694-3297 REPL. TRENCH 1,000 GAL. ~ TI APPRDXIMATE LDCATIDN DF HDUSE ND SURVEY +10' 2' 35PSI INSUL S 89°59'0' E 105.80 LBT 36 SEPTIC PIT 76-87' DISTANCE NO SURFACE WATER NO KNOWN CURTAIN DRAINS ORIGINAL PERMIT #SW95-0400 SEPTIC SITE PLAN LEGAL: LOT 40 DELUCIA OWNER: MILLER CONTRACTOR: N/A JOB # 94-085 DATE: 05/07/95 SCALE 1" = 40' A EAGLE RIVER ENGINEERING SER VICES P.O. Box 773294 EAGLE RIVER, AK. 99577 (907) 694-5195 FAX: (907) 694-3297 ~,- - MONITOR WELL · - MONITOR TUBE o - SEWER CLEANOUT q>- - WELL , - PROPOSED LEACHFIELD ~5-~4-1995 Ol:55PM FROM E.R. Engineepin9 Sues. TO 3434?86 P.82 TOTAL P.02 p ~77 786 112 Receipt for Certified Mail No Insurance Coverage Provided ~,,~ for international Mail ~,EOSt~e~ DO not use ~,o~,,~, ¢, (See Reverse) _._.__--------- ,ent to '~'vid Miller __----------- treet ar, d No ' ^--~ Ave Postage ~estricted Dehve ¥ · ~etum Receipt S g to V~'hom & Date Delivered Date, and Addressee's Address -- TOTAL Posta9e & Fees Postmark or Date STICK POSTAGE STAMPS TO ARTICLE TO COVER FIRST CLASS POSTAGE, CERTIFIED MAIL FEE. AND CHARGES FOR ANY SELECTED OPTIONAL SERVICES {non front). I. if you want this receipt postmarked, stick the gummed stub to the right o! the return address leaving the receipt attached and present the article at a post office service window or hand it to '¢our 'ural carrier {r,o extra ~harge). ? If you do not want this receipt postmarked, stick the gummed stub to the right of the return a~dr~ss o[ the artirle,.date, detach and retain the receipl, and mail the article. 3. It you want a re*~'n recPipt, write the certified mail number and yaur name and address on a return [ece~pt card Form 3811, and attach it to the front of the article by means of the gummed ends ;[ spaL.e permits. Otherwise, affix ~o hack of article Endorse front o! article RETURN RECEIPT REQUESTED adiacent to the number. 4. it you want delivery restricted to the addressee, or to an authorized agent of the addressee, endorse RESTRICTED DELIVERY on the front of the article. 5. Enter fees Io~ the sec'vices requested in the appropriate spaces on the front of this receipt, if retur9 receipt is requested~ check the applicable blocks in item 1 of Form 3811. 6. St, ye ti,is receipt and present it if you make inquiry. : U.S. GPO: 199t--302-916 MAY Ii 1995 D Mun, ic~pality of An~ e?'," ,.[qalth & Human · Print your name, addres~ and ZIP Code here RiCK Mystrom, Mayor Municipality of Anchorage Department of Health and Human Services 825 "L" Street P.O. Box 196650 Anchorage, Alaska 99519-6650 343-4744 April28,1995 Arvid Miller 6701 East 10th Avenue Anchorage, Alaska 99504 Re: Permit SW940427, Lot 40 Delucia Subdivision, P.I.D. 051-141-11 Dear Mr. Miller: This office recently received information that the well constructed on Lot 40 Delucia Subdivision on April 20, 1987 is encroaching on the wastewater system serving Lot 36 Delucia Subdivision. The wastewater system on Lot 36 was in place at the time you constructed the well on the subject lot. Municipal code prohibits the construction of a water well closer than 100 feet from a wastewater system. As a result of this recent discovery, this office is rescinding the subject permit number SW940427 until the separation problem between your well and the neighboring wastewater system is corrected. This letter will serve as your notification that construction of the proposed wastewater system which the subject permit was issued for cannot proceed at this time. If you have any questions of the above notification, please contact me at 343-4744. Program Manager On-Site Services NOTE: Application must be filled out completely Property Owner Name /~,~////~ /~//..~/~ Mailing Address ~ '~/ ~ /~ ~ ~ ./ Legal Description ~ ~ Lot Block Number of Bedrooms: ~ MUNICIPALITY OF ANCHORAGE Department of Health & Human Services On-Site Sewer/Well Permit Application SINGLE FAMILY DWELLING Of;/ --!/ Parcel Identification Number Day Phone .~'33 ~' Zip Code ? ~~ Subdivision Ins.pe/ctions will be conducted by: X Approved Engineering Firm Municipality (permit fee included) Does your house contain any of the following: Hot Tub, Swim. ming Pool, Therapy Pool, Jacuzzi, . or Water Soften_er Unit? /~//,/~' If yes, which one? //~///~ /..~'L.//,/~-, This application is for: Sewer Only Sewer and Well __ Sewer Upgrade Well Only I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and in accordance with applicable Municipal codes. ! ' Property/Owner/W~;; D,;;;~r Fees: Receipt # Permit # 72-012 (Rev. 10/86) PAGE 1 OF 1 MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND HUMAN SERVICES P.O. BOX 196650, 825 "L" STREET, ROOM 502 ANCHORAGE, ALASKA 99519-6650 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT PERMIT NUMBER:SW930440 DESIGN ENGINEER:CONSTRUCTING ENGINEERS, INC. OWNER NAME:MILLER ARVID & WANNETA OWNER ADDRESS:22839 DANIEL CT EAGLE RIVER, ALASKA 99577 DATE ISSUED:10/20/93 EXPIRATION DATE:10/20/94 PARCEL ID:05114111 LEGAL DESCRIPTION: DELUCIA LT 40 LOT SIZE: 15682 (SQ. FT.) NUMBER OF BEDROOMS: 3 THIS PERMIT: THIS PERMIT IS FOR THE CONTRUCTION OF: DISPOSAL FIELD /SEPTIC TANK SYSTEM ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH: 1. THE ATTACHED APPROVED DESIGN. 2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS 15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80). 3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY CALLING 343-4744 OR 343-4681 AFTER BUSINESS HOURS 4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING WEATHER MUST BE EITHER: A. OPENED AND CLOSED ON THE SAME DAY B. COVERED, SEALED AND HEATED TO PREVENT FREEZING 5. THE FOLLOWING SPECIAL PROVISIONS. SPECIAL PROVISIONS RECEIVED BY: ABSORPTION SYSTEM DESIGN DETAILS--STANDARD T~ENCH J SCOPE OF PROJECT: New absorption field is designed for a three (3) bedroom system. Lot is served by a private well. The system will be a standard gravity absorption system with a deep trench. ABSORPTION AREA CALCULATIONS: Minimum Required: 3 Bedrooms x 150gpd/bedroom = 450 gpd capacity Soils rating, proposed addition, 1.2 gpd/sf Minimum sizing: 450 gpd + 1.2 gpd/sf = 375 sf absorption area Use 3'W x 19'L x 10' D = 380 sf minimum for trench Trench depth: Bottom = 14' Below grade, w/ 4' cover IMPACT ON ADJACENT LOTS: There are no private wells within 100' and no public wells within 200' of this absorption system; The proposed absorption system impacts adjacent lots as shown on attached site diagram. DESIGN DETAILS PROPOSED WASTEWATERABSORPTION SYSTEM LOT 40 DELUCIA SUBDIVISION PREPARED FOR: ARVID MILLER 6701 E 10TH AVE ANCHORAGE, AK, 99504 333-2996 NOT TO SCALE DRAWN BY CAL CONSTRUCTING ENGINEEr346-2000 9601 BUDDY WERNER DR 694-9098 ANCHORAGE, AK, 99516 10-12-93 D~#ING # 9~S2-1~3 SITE PLAN-WASTEWATER ABSORPTION SYSTEM SITE PLAN DETAILS PROPOSED WASTEWATERABSORPTION SYSTEM LOT 40 DELUCIA SUBDIVISION PREPARED FOR: ARVID MILLER 6701 E 10TH AVE ANCHORAGE, AK, 99504 SCALE: 1" = 100' 333-2996 DRA~N BY CAL CONSTRUCTING ENGXNEERS346-2000 9601 BUDD~ WERNERDR 694-9098 ANCHORAGE, AK, 99516 10-12-93 DRNdlNG # 93-SI-I0'-'3 SITE PLAN-WASTEWATER ABSORPTION SYSTEM O SITE PLAN DETAILS PROPOSED WASTEWATERABSORPTION SYSTEM LOT 40 DELUCIA SUBDIVISION PREPARED FOR: ARVID MILLER 6701 E 10TH AVE ANCHORAGE, AK, 99504 SCALE: 1" = ;~0' CONSTRUCTING ENGINEERS3&6-2000 9601 BUDDY WERNER DR 694-9098 ANCHORAGE, AK, 995'16 333-2996 DP. Al,IN BY CAL 10-12-93 # 93-S3-10-3 J ABSORPTION SYSTEM DESIGN DETAILS--STANDARD TRENCH SCOPE OF PROJECT: New absorption field is designed for a three (3) bedroom system. Lot is served by a private well. The system will be a standard gravity absorption system with a deep trench. ABSORPTION AREA CALCULATIONS: Minimum Required: 3 Bedrooms x 150gpd/bedroom = 450 gpd capacity Soils rating, proposed addition, 1.2 gpd/sf Minimum sizing: 450 gpd + 1.2 gpd/sf = 375 sf absorption area Use 3'W x 19'L x 10' D = 380 sf minimum for trench Trench depth: Bottom = 14' Below grade, w/ 4' cover IMPACT ON ADJACENT LOTS: There are no private wells within 100' and no public wells within 200' of this absorption system; The proposed absorption system impacts adjacent lots as shown on attached site diagram. DESIGN DETAILS PROPOSED WASTEWATERABSORPTION SYSTEM LOT 40 DELUCIA SUBDIVISION PREPARED FOR: ARVID MILLER 6701 E 10TH AVE ANCHORAGE, AK, 99504 333-2996 NOT TO SCALE DRAWN BY CAL CONSTRUCTING ENGINEERS346-2000 9601 BUDDY WERNER DR 694-9098 ANCHORAGE, AK, 99516 10-12-93 DRAWING # 93-S2-1~3 SITE PLAN-WASTEWATERABSORPTION SYSTEM 143 SITE PLAN DETAILS PROPOSED WASTEWATER ABSORPTION SYSTEM LOT &0 DELUCIA SUBDIVISION PREPARED FOR: ARVID MILLER 6701E 10TH AVE ANCHORAGE, AK, 99504 333-2996 SCALE: 1" = 100' DRAWN BY CAL CONSTRUCTING ENGINEERS346-2000 9601 BUDDY WERNER DR 694--9098 ANCHORAGE, ,ILK, 99516 10-12-93 DRAWING # 93-S1-10-3 SITE PLAN-WASTEWATER ABSORPTION SYSTEM o lc SITE PLAN DETAILS ~'~- P~__?POSED WASTEWATER ABSORPTION SYSTEM -',..'.,< Oc ~ ~ ~T 40 DELUCIA SUBDIVISION ~..~ %-~'.~?~ z %-, ~ PREPAID FOR: ARVID MILLER 333-2996 ~ff~ -~~ ~ ~CHO~GE, AK, 99504 ~. ~32-E :'~ SCALE: 1" = 20' D~"N BY CAL '* ~" '~ ,~ ~ CONSTRUCTIN~ ENGINEERS 346-2000 ~~~ ~o~o~, ~, ~s:s :o-:~-~a PERFORMED FOR: LEGAL DESCRIPTION: Municipality ol Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST Township, Range, Section: 5'E;//4 5c~ TISIV r~lv~ 1 2 3 4 5 6 7 8 9 10 SLOPE SITE PLAN WAS GROUND WATER ENCOUNTERED? 11 12 13 s L IF YES, AT WHAT O DEPTH? P E Depth to Waler Alter Monitoring? ~or~ ~ Dale: 14 15 16 17 18 19 2O Gross Net Depth to Net Reading Date Time Time Water DrOp I ' z / 5',-,, ,',- ¢ ,.-,.. ~' 'A ~ y "A~" ~,~ ~ to'%¢ t"' 4 ;~ .... ~,- ~ 13" I '~" ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. 72-008 {Rev. 4/85) PERCOLATION RATE ~ Im~nutes/inch) PERC HOLE DIAMETER TEST RUN BETWEEN °¢' FT AND 9 FT CERTIFY THAT THIS TEST WAS PERFORMED IN DATE; I O' I "[."~ ~ MUNICIPALITY OF ANCHORAGE MEMORANDUM DATE: TO: THRU: FROM: SUBJECT: August 4, 1992 Leslie Jordan, Counter Supervisor, Building Safety John Smith, P.E., Program Manager, On-Site Services Dan Roth, Civil Engineer, On-Site Services~ On-Site Wastewater Disposal Permit Revocation For Lot 40 Delucia Subdivision, P.I.D. 051-141-11 The permit number SW900064 for the above referenced property to construct an on-site wastewater disposal system has expired. The property owners have been advised not to perform any work until they have submitted a new permit application for construction of an on-Site wastewater disposal system to this office and an updated permit has been issued. cc: Dave Brennen, Code Enforcement Manager, Land Use Enforcement Stan Hoofard, Code Enforcement Officer ] unicipality of Anchorage Department of Health and Human Services Tom Fink, 825 "L" Street Mayor P.O. Box 196650 Anchorage, Alaska 99519-6650 January 8, 1991 Arvid Miller 6701 East 10th Avenue Anchorage, Alaska 99504 Subject: Lot 40 Delucia Subdivision Permit #900064, PID #051-141-11 The subject permit, issued by this office for a single family well and/or on-site wastewater system has expired as of December 31, 1990. A new permit must be obtained from this office for a well and/or on-site wastewater system not installed by the expiration date. If you have drilled the well, a well log needs to be sent to this office for documentation of the installation and to close the permit. If a private engineer inspected the installation of the on-site wastewater system, the original as-built inspection report (three-part form) must be sent to this office for review, approval and documentation. All inspection reports must be submitted within 30 days of construction completion. When applying for a new permit, the fees are: $90.00 for an on-site wastewater permit; $50.00 for a well permit; $140.00 for a combined on-site wastewater and well permit. If you have any questions, please call this office at 343-4744. JW/ljm:200 enc: Copy of Permit "Kids Are Our Future" unicipality of Anchorage Department of Health and Human Services Tom Fink, 82,5 "L" Street Mayor P.O. BOX 196650 Anchorage, Alaska 99519-6650 January 8, 1990 Arvid Miller 6701 East 10 Avenue Anchorage, Alaska 99504 Subject: Lot 40 Delucia Subdivision Permit #890011, PID #051-141-11 The subject permit, issued by this office for a single family well and/or on-site wastewater system has expired as of December 31, 1989. Permits are issued on a calendar year basis by authority of the Municipal Code of Regulations. A new permit must be obtained from this office for an well and/or on-site wastewater system not installed by the expiration date. If you have drilled the well, a well log needs to be sent to this office for documentation of the installation and to close the permit. If a private engineer inspected the installation of the on-site wastewater system, the original as-built inspection report (three-part form) must be sent to this office for review, approval and documentation. ~ When applying for a new permit, the fees are: $90.00 for an on-site wastewater permit; $50.00 for a well permit; $140.00 for a combined on-site wastewater and well permit. If you have any questions, please call this office at 343-4744. Sincerely, John Smith, P.E. Program Manager On-site Services JW/ljm:200 enc: Copy of Permit "Kids Are Our Future" ..]~,~.Jn(.~r' (:.~(::J~::! F e~-~i~S ',: ~ i:~('~.'I Jill . J. ';7.) ~..~/' '.¢"1:::., A N 3 H(J R'A GE ,, A K ):)ay' Phone." '~' "-T":? ,', ' ('~ ,.'~ L,':)t l...ecla !: Subd :i. v i s i c)n: DIEI....UC ]: A Lot: 40 B 1 c)c: t-::: .-. Sect ic:~n~ 9 "l"ownship:', 15N l::(ange~ :I.W ~_,...~.. ~:i. :~: ~_.t ~..~'~c~c,.:.,::. (scl,, f ~'~., (::)r~ ac: r'. (.:es .) fda x Bed r. (::)~:~ms ~ Th :i. s F:'e r m i t :', 3 'l'-c:~'b a ]. Ca p ac: ~ t y ~ :3 3F.!'F' T I C: "l' ANk: M :i ~"~ :i. rnum 'Lcd:.a. I sept :i. c: tan I.:: (::at::)ac i'l: v: 1., C)OC) ga 11aris,, leach sept. :i. c ..... '~, () 'i:.ar~l.-: nl'~ ~. ~ g~r ~:i lilt a~. '~,' ~? at ].east 2 ccmq::~ar.'[.rnen{s,, DepCh '~(:, t. op c:,f sept:Lc tarlk (s) · ~.' e (.?,'[: r' e q 1.! :J r. e s :i. n s u :l. a t :L o n C) V (C~' P '[ ~ ri J.:; ( ~ ) . ~"'..1 ]: :iii~ F'ERh! ]: '1 :I: !~!!: A RL:..'.' i: !-:~¢:~ tF:' OF: F:'IERM ]: 'T' :~08() I ': .................. :~,..~, I',!OT I F:'Y ]}!.-II.~S PR I OR ~'0 I~[:::~t::t...l :I:b.tS!:::'E]]I' ]:OIq BY I'I...iE IEIqG IlqlEIER, 'T'H]:S F:'ERM ~ T tS I ~SUED FOR fF.tE. IE).: :l:S'f':l:Nt.:.) 3 BE:[)F~'.EK)M DI/JEL..L..IIqG PIER DIRECT IC)N OF L..EE BROWN]:NG PiE I: C;ER'I ]:I:::"Y '!I.IA'T ~ .I ....~: a[:q ~ am:~. ]. :i. ar' with i:.h,:-~ P(~:,(::IL~ P(.?m~::.H"it:..S fC)F' c) r~ -- s :L 'L ~e se~,]er's and ~E.)]. ].E~. a~ ~e~. fc.,r.'Lh t:)v 'Ll't(:a Mur'~:[c:Z~::)a].:i.!'..'~/ c)f Ari,::ho['age (NC)R) ar'id '?,, ]. t,.,l'l ] ]. 'i r]~5t:...~i~. ]. 4.L~l.:e ~:~.'~:~u::r~m ].13 E~cT(zc) r"da!"l(zE' bli't.h al ~L J'"'J · :¢ .i sc:. ~..(~-'~(':16)~1" s't .:':,Fid I.'..hat '~..he capac :i. ty c,f the '('..ora ]. system ~ s 3 b<:-:.)c:l['c)(:::,ms amcl ,:;Ch.,,n"~ (.:::, r. ) F~I::;~V 1 D MI L..t....ER Tom Fink, Mayor ;v unicipality of Anchorage Department of Health and Human Services' 825 "L" Street P.O. Box 196650 Anchorage, Alaska 99519-6650 343-4744 January 1989 Arvid Miller 6701 East 10th Avenue Anchorage, Alsaka 99504-1813 Subject: Lot 40 Delucia Subdivision Permit #880165, P.I.D. #051-141-11 A permit issued by this Department for an individual well and/or on-site sewer system has expired as of December 31, 1988. .~ Permits are issued on a calendar year basis by authority of Municipal Ordinance. A new permit must be obtained from this Department for any well and/or on-site sewer system not installed by the expiration date. If you have drilled the well, a well log needs to be sent to this Department for documentation of the installation and to close the permit. If a private engineer inspected the installation of the on-site sewer system, the orginal as-built inspection report (three-part form) must be sent to this office for review and approval, and for documentation. When applying for a new permit, the fees are: $90.00 for an on-site sewer permit; $50.00 for a well permit; $140.00 for a combined sewer and well permit. If there are any further questions, please call this office at 343-4744. Sincerely, Daniel J. Roth Acting Program Manager On-site Services Section DJR/ljw enc: Copy of Permit M U N I C :I: P A L :I: T Y (] I:::' A N C H 0 R ~ G E De!::,artment.. of Health & Human Serv±ce.s 82.5 t .... Str-eet~ Ar'~c:horage, Alaska 99501 3Zl. 3-472'0 C) N .... S I T E S E W E F;'. & W E L L P E R M I T F::'er re:Lt. Number': 8801.65 Dat..e Issued: 08/.t. 9/88 Enoineep Designed O~.,.~ner. Name: ARVID MILL. ER Owner Addpess: 670t EAST lOTH AVENUE ANCHORAGE, AK 995()4- .1.8 i. 3 [)ay F'hone: Parcel Id: ()5.l-141-'11 L..c)t L. eoal: Subd:ivision: DELUCIA SUBDIVISION Lot: 40 Block: - Sect.,ion:~ 9 Township: 15N Rar"~r:~e: 1W L. et Size 15682 (sq. ft. or acres) Max Bedr'ooms: This Per'mit: 3 'l"otal Capac:ity: 3 SEPTIC TANK: MinimLtm total septic: tank capac:ity: t,O00 gallons. Each sept:i.c t. ank mLtst have a'L least 2 compar'Lments. Depth to top of septic tank (s) < 4.0 feet requ:i.r~es insulation ove~~ 'tank (s). WEL.L: L..o(] must be submitted to Municipality of Anchorage Depantment o{ Health and Human Sepvic:es within 30 day~ of well completion. INF:'ORM D.H,,H.S. F'RIOR TO 1ST & 2ND INSPE:CTIONS BY ENGINEER~, IF AFTER OFF'ICE HOURS, CALL 343-4681 AND L. EAVE A MESSAGE. CONSTRUCT PER ENGINEERS ATTACHED DESIGN. T'HIS I:::'ERM!T EXF:'IF~ES 12/31/88, THIS PERMIT VAL. ID FOR A SINGLIE FAMILY RESIDENCE ONLY,, CE:F: I"I FY THAT: I am familiar with the requirements for' on-site sewers and wells as set. ¢c:,rt.h by the Idunicipa].ity of Anchorage (MI]A) and the State of Alaska, I (,~i:t.:L :i. nsta].l the system in a(:cor'dance with all MOA c:odes and regu].a'l:..:i, ons, and in compliance with the des:i, gr~ c~it. er:i.a of t.h~s permit., I will adhe~"e to alt MOA and State of Alaska requirements for the set back distances f'rom an~,, existing we].:l.T, wast. ewaten disposal system of public sewer.age s~'st, em on t..his c)r' any adjacent, op F~eapbv 3 bedr'ooms, 3 bedr'ooms and Zl.,, t under's'Land that {his permit, is va].id for. a maximum of' also under'stand that the capac::i, ty of' the to'Lal system .t~s ar-~y enlar'.gemen+... ~.~:i.].l requir'e an additional per'mi+..,, S J. 0 r"~ e d = (Owner) I !.-] su ecl Municipality ol Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST (EINGINEER'S SEAL) PERFORMED FOR: ~1~. ./~I~._~/IL~ 1~11 i_~2._. DATE PERFORMED: ~'/ I.{ /~;;~'/ LEGAL DESCRIPTION: 1 2 3 4 7 10 11 12 14 16 17 18 19 2O Township, Range, Section: SLOPE SITE PLAN WAS GROUND WATER ENCOUNTERED? NO IF YES, AT WHAT '~ / -- / Z:3/~7~1~,~ DEPTH7 Depth to Water After Monitoring? . Date: Gross Net Depth to Net Reading Date Time Time Water Drop PERCOLATION RATE __ (minutes/inch) PERC HOLE DIAMETER COMMENTS PERFORMED BY: ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. TEST RUN BETWEEN __ FT AND -- FT I '.'~1--)~,'~'~1- .~. ~'~---I~- CERTIFY THAT THIS TEST WAS PERFORMED IN DATE: 7-- ~J'~ - ~7 72-OOR II;lev unic pality of Anchorage Department of Health and Human Services 825 "L" Street Tom Fink, Mayor P.O. BOX 196650 Anchorage, Alaska 99519-6650 June 9, 1988 Enayat S. Aziz, P.E. Aziz Engineering Company 9024 Vangard Drive, Suite 201 Anchorage, Alaska 99507 Subject: Permit Application For. On-Site Septic And Well For Lot 40 Delucia Subdivis±on Dear Mr. Aziz: This letter is in response to your letter of June 1, 1988. As we discussed on several occasions during August and September of last year by phone and in person, On-Site Services has several concerns regarding the permit application submitted by you for the subject lot. These concerns are: The inability to meet technical requirements of the Ordinance for a standard on-site wastewater disposal construction permit, and the existing problem with elevated nitrates in the drinking water supplies in the immediately surrounding area of the subject lot. We also discussed at this time that the technical requirements the subject lot could not meet may possibly change because several amendments to the ordinance were scheduled to be heard in October by the Anchorage Municipal Assembly and most likely adopted. To this date the Assembly has moved to postpone the amendments until a special advisory committee could review and recommend changes to the existing ordinance. In the interest of expediting the permitting process for the subject lot, I recommend that you meet with myself, Susan Oswalt, and Lee Browning on June 15, 1988, 3:00 p.m., at the Department of Health and Human Services. If this time is not convenient for you then contact me so we can reschedule. Sincerely, Daniel J. Roth Civil Engineer On-Site Services cc: Lee Browning, P.E., Manager Environmental Services Division Municipality of Anchorage Department of Health and Human Services Tom Fink, 825 "L" Street Mayor P.O. Box 196650 Anchorage, Alaska 99519-6650 343-4744 October 25, 1988 Arvid Miller 6701 East 10th Avenue Anchorage, Alaska 99504-1813 Subject: Waiver Request for Lot 40 Delucia Subdivision Waiver Request ~WR88-048, Permit #880165 Dear Mr. Miller: Your request for waiver of the required 10 foot separation between a septic system and a lot line has been approved. waived distance is 1.5 feet. The This approval applies to the existing septic system lot line separation only. Any future upgrade to the septic system will require all separations be met or another approval from this department. Sincerely, Daniel J. Roth Civil Engineer On-site Services DJR/ljw#7 ENGINEERING COMPANY ENGINEERS · PLANNERS ' SCIENTISTS 9024 Vanguard Drive. Suite 201 ~/~ Anchorage, AK 99507 Ph. (907) 349-2557 June 1, 1988 11287 Mr. Gus Andrews Manager, On Site Services Municipality of Anchorage Dept. of Health and Human Services Pouch 196650 Anchorage, Alaska 99519 HAND DELIVERED Reference: hot 40, Delucia Subdivision, Peters Creek - Permit for On-Site Wastewater Disposal System Dear Gus: The on-site wastewater disposal permit application for the above referenced property was submitted to your department on August 26, 1987 together with engineered construction plans and design calculations for the system. Your department has not reached a decision about this property since August of last year. Reference is made to my letter dated August 26, 1987 addressed to Daniel Roth of your Department. Since September of last year I have had numerous discussions with Dan Roth, Steve Morris and Robby Robinson of your Department about this permit application. They maintain that there is a problem with the replacement area for this property, due to inconsistencies in the present ordinances. In our design, we considered the replacement area to utilized the same type of disposal system as the original, which requires less area than a convential system. I'm still not convinced that there is a problem here. My belief is confirmed by the fact that 15.65.040 Paragraph 4 allows an engineered alternative in lieu of an on-site replacement area, as applicable to this property. Nevertheless, to date we have no statement of a decision from your Department, or even a reply to my August 26, 1987 letter concerning this property. I would like to get this resolved. During my last conversation with Robby Robinson on April 14, he indicated that there is a way to solve this problem from your Department's standpoint, by requiring the replacement area to be constructed at the same time as the original disposal field. If the proposed ordinance amendments, which are now approved by the Page 2 Lot 40, Delucia Subd./Peters Creek June 1, 1988 Assembly task force and recommended for adoption, were in effect today, there will be no problem with our proposal for this property, and I am sure that Robby Robinson of your Department will concur with this conclusion. Frustrated as we are we would like to proceed in the manner that Mr. Robinson suggests. The property owner has a major problem at his hands right at the moment: A residential structure was moved to the site last year, which now sets on temporary timber pedestals. This is very unsafe, and nothing can be done about it until the water and wastewater disposal permits for the property are granted, as a result of a stop-work order issued by the Municipality last year. The property owner has done everything that he can since that time to obtain the required permits. Your department has taken an unreasonable length of time to come to a decision on this case, either approving or denying the permit applications. I am sure you will agree that there is no basis here for a denial. We ask that you review this case as promptly as possible. I will be happy to answer any questions that you may have at your convenience. Please give me a call. Sincerely, ~nayat S~A~iz,~P.E. ESA/tb cc: Mr. and Mrs. Arvid Miller of Peters Creek Mr. Robby Robinson, Dept. of Health and Human Services AZIZ ENGINEERING COMPANY Ii ,CHEMICAL & GEOLOGICAL LABORATORIES OF ALASKA, INC. FEDERAL TAX ID # 92-0040440 CHEMICAL & GEOLOGICAL LABORATORIES OF ALASKA:~NC. TELEPHONE (907) 562-2343 5633 B Street Anchorage, Alaska 99518 Drinking Water Analysis Report for Total Coliform Bacteria TO BE COMPLETED BY WATER SUPPLIER [] PUBLIC WATER SYSTEM I.D.# I [] PRIVATE WATER SYSTEM Name PhOne No. ~' Mailing Address City State Zip Code Mo. Day Year SAMPLE TYPE: [] Routine [] Check Sample (for routine sample with lab ref. no. [] Special Purpose [] Treated Water [] Untreated Water SAMPLE NO. LOCATION Time Collected Collected By TO BE COMPLETED BY LABORATORY Date Received Time Received Analytical Method: Analysis shows this Water SAMPLE to be: (~ Satisfactory [] Unsatisfactory [] Sample too long in transit; sample should not be over 30 hours old at examination to indicate reliable results. Please send new sample via special delivery mail. Membrane Filter * No. of colonies/100 mi. Lab Ref. No. Result* I VTq I VT] Analyst BACTERIOLOGICAL WATER ANALYSIS RECORD READ INSTRUCTIONS Membrane Filter: Direct Count Coilformll00ml BEFORE COLLECTING SAMPLE Verification: LTB Final Membrane Filth' Results Reported By __c~.~._.. ~-~ Date Time: BGB O Coilformll00ml /~7~0 a.m. TNTC = Too Numberous To Count OB = Other Bacteria MUNICIPALITY OF ANCHORAGE MEMDRANDUM Date: To: From: Subject: August 17, 1988 File Daniel 3. Roth, Civil Engineer/ Acting Manager, On-Site Servi~Program Permit issuance for Lot 40 Delucia Subdivision Owner, Arvid Miller, P.I.N. 05114111 Aftex much deliberation with; Lee Browning P.E., Envixonmental Services Oivision Manager; Enayat Aziz, P.E., Arvid Millers engineer; Susan Oswalt, Environmental Specialist in On-Site Services; and Daniel Roth, Civil Engineer, Acting Program Manager for On-Site Services, a permit for the installation of an on-site wastewater disposal system is being issued. After the M.O.A. Legal Department reviewed the On-Site Wastewater Disposal Ordinance, they determined that in defending the ordinance a permit could be issued or could not be issued. With this finding Lee 8rowning ordered a permit be issued to Arvid Miller for the installation of both the o~iginal and replacement absorption bed to be installed at the same time for our assurance that the replacement site will be available in the future. ENGINEERING COMPANY ENGINEERS ' PLANNERS ' SCIENTISTS August 16, 1988 5)024 Vat, guard Drive, Suite 201 Anchorage, AK 99507 Ph. [907] 349 2557 Al1287 Mr. Daniel J. Roth, Civil Engineer On-Site Services Municipality of Anchorage Department of Health and Human Services Pouch 196650 Anchorage, Alaska 99519 Reference: Revised Engineering Drawings for On-Site Wastewater Disposal System Lot 40, Delucia Subdivision, Peters Creek Dear Mr. Roth: Pursuant to our recent discussions, the design and construction drawings for the above referenced wastewater disposal system have been revised per your requirements. The design and construction plans for the replacement disposal area is now included in our submittal, and a note pertaining to the minimum well clearance has been added to the drawings. Attached are three sets of blueprints for the above and one copy of our revised calculations for your information and records. As we have discussed, I have strong reservations about the alternating use of disposal fields. I prefer that the primary disposal bed is used for 15 to 20 years, until the sand bed looses its treatment capacity as a result of biomass build-up. This can be determined from samples taken at the monitering well. Only then, the replacement disposal bed should be activated while the primary sand bed is replaced and the subsoils are allowed to relax for a period of 5 to 10 years. I will advise my client to keep a copy of this letter readily available at the property, and place a lable at the moniter well with reference to this letter and where to find it. With all the hassle that we have gone through over this property, I trust that you will do the best to expedite the permits for this property, and I hope that the information transmitted with this letter is sufficient for your information and records. Please call at your earliest convenience if there are any questions. Sincerely, AZI~flNGINEERING COMPANY Enayat S. Az~, P.E. MUNICIPALITY OF ANCHORAGE DEPT. OF HEALTH & ENVIRONMENTAL PROTECTION 1988 ESA/tb cc: Mr. and Mrs. Arvid Miller RECEIVED ~ ~ o II c: I1 0 ('lJ) DUl:)~dS U°l)eJ°lJed A ENGINEERING COMPANY ENGINEERS · PLANNERS ' SCIENTISTS 9024 Vanguard Drive, Suite 201 Anchorage, AK 99507 Ph. (907] 349 2557 2ispss.!:i Sys lLpp2 :V,P.~ "~ ~: i-ii 87. AZIZ ENGINEERING COMPANY July I, 1987 Municipality of Anchorage Department of Health and Human Services Pouch 196650 Anchorage, Alaska 99519-6650 Reference: Lot 40, Delucia Subdivision. (Plat P-684). 11287 STATEMENT OF NON-OBJECTION This letter is to confirm my non-objection to the installation of the on-site sewage disposal system within two feet of my common property line with the above described real property, i am the owner of Lots 8 & 39, Delucia Subdivision. I ~ ~ understand that certain setback restrictions will be imposed as a result of this installation and that such restrictions will not place unecessary constraints upon my property. Sinc'erely, L.G. Gardner SR1, ~ox 1088 Chu~-~k.~Flask~ 99567 STATE OF ALASKA ) ) ss. THIS IS TO CERTIFY 5hau on this ~day of ~. , 1987, before me, the undersigned, a Notary Public Win ~nd for Alala~_,,.a, duly commissioned and sworn, personally appeared ~,~z~x~._~F~_~/~ , known to me ~o be the individual named in and who executed the foregoing instrument and acknowledged to me that ~ signed the same freely and voluntarily, for the uses and purposes therein mentioned. WITNESS my hand and official seal. NOTARY PUBLIC ~STATE LASKA My Commission Expires: ....... ,~..~.,~. ~. ~.a F~r The State O~ A~k~. ~,y Commission Expires ~AARCH 28tfl 1990. ENGINEERING COMPANY PROJECT,. .-/~"l~-.-~ ~ ~I~ ,.~.,~.,, AUTHRZ. NO. 1t '~ ~.~: '-7 SUBJECT. pATE ~O/I- ~COMPUTED BY ~.4t~,~ CHECKED BY ~ ~ AZIZ ENGINEERING COMPANY 11024 VANGUARD DR., ~UITE 201 ANCHORAGE, ALASKA 99507' ~Te4~.c L.e.~o % = ll,~q .d LOT4O AZIZ ENGINEERING COMPANY 1{I24 VANGUARD DR., SUITE 201 SECT. 100 TAB Effluent Pumps PG. 101 ~ OATE January 1, 1986 I t MODEL SEVH- 4w SESH- 5W 10Wi 20W 961 I I RATED HP 0.4 0.5 ~.0 2.0 II J I SOLID SIZE 3/4 SLADE 2 SPEED 3450 RRM * 60 ' I I VO,T^~E 84 = I I ~ ~ 48 - J ~1 -36 I I '~ 40 60 80 100 120 140 USGPM * SEVH-4W: l15V or 230V, 208V SESH-5W: 115/230V, 208V SESH-10W and SESH-20W: 230V only MUNICIPALITY OF ANCHORAGE MEMORANDUM [:`ATE: TO: FROM: June '15, 't989 Nell Leoriar. d, Zor~irl9~ Code enfoccement. [:'.anie] Bo]les., O,q-site Ser. vices~¢~ Lot 4(::, _ u,:i S~,'.hd vi 4 _ __ 1 m~ter, youp phnne -.~ll i four~,i that ther-e ,was. no ,~,r.'' pefepence to the K~oYiRg of t~Fe ,:~4uonset hut. ~ discussed this with [:`an Roth a CE in our- offi,;e. He pemember, s that th.e ,:;:~uor, set hut ,was to be r. emoved. We felt tha~ sir, ce the engineer, s design drawings depicted r~o other, str-uctur, es or~ the l ot~ except the pF. iRcipie .... dwe~ilr~g~ ~-~.~,~.,. ~,¢~ ..... (;)uonse+ ....... hu+ had beer~ np w.~s moved. Z( was ,¢ith this un~derstar~diF~t~ that ,~,e issued the permit to cor~stpuct. I have iRc!uded a copy of AMC '15 '~. .... ..._,_.- aF~d the Plar~F~ed site tavnut If ".,"o~: wish to see rrioF, e of the file OF' discuss these please ':all u~- ._-.to:, bY at ¥OUF' ,_-or~ver~ieR,_-e. ,-I, b/76 Municipality of Anchorage Department of Health and Human Services Tom Fink, 825 "L" Street Mayor P.O. Box 196650 Anchorage, Alaska 99519-6650 343-4744 October 25, 1988 Arvid Miller 6701 East 10th Avenue Anchorage, Alaska 99504-1813 Subject: Waiver Request for Lot 40 Delucia Subdivision Waiver Request $WR88-048, Permit.#880165 Dear Mr. Miller: Your request for waiver of the required 10 foot separation between a septic system and a lot line has been approved. waived distance is 1.5 feet. The This approval applies to the existing septic system lot line separation only. Any future upgrade to the septic system will require all separations be met or another approval from this department. Sincerely, Daniel J. Roth Civil Engineer On-site Services DJR/ljw#7 August 3, 1977 ~id Miller Star P~ute Box 9~9 Chugiak, Alaska 99567 Subject~ Permit Expiration Dear Mr. Miller: A permit issued by this department for well and/or on-site sewer installation on Lot 40 Deluoia Subdivision has expired since the issue date exceeds one (1) year. In the event you still plan to install the well and/or on- site sewer system, a new permit is required. The original soil test may be used to obtain a current permit. If the well has been drilled, a well log should be sent to this department to document the installation date. If you have any questions regarding the above matter, please do not hesitate to contact this office immediately at 279- 2511, extension 224 or 225. Sincerely, Les N. Buchholz, R.S. Sanitarian LNB.lJh P Ei:;.:H I T N O. DEPFIF:fr'HENT i..,.'IEFILTH FINE:, iENV.r RO.NHE:NTFtl .... CT[EE:T I ON i...-II E.E IL. L. E~ t"4 E::, ~]::~ I"-.11 ........ ."E:-; :]I:; -r' E:: .".~T; E; [t...,tt E% F'.". II::' E.:E: F:: ['-'!I :]E "T'- ,:: ';:'E;,::~62 .':, --i. r' L .r L.EIE:FIT I ON L. E 13 Ft L RR:',,,'.I [:, r'l I k_L. EF.~ E,Et--_UC I R ':.- .IE:[: .~' 'I S I ON [,EL JC: I Ft SUB LOT SIZE j. 50C1Cl ...... '"- F'E;E'T "i"YF'E OF S3IL FtE:SFIRE:TION SYSTEH IS;' F'IT t','IFI;:-::IMIJH NIJP1E:EF.: nF E:EDR:OOr'1% = 4 S, Lh I L RFIT I NG ( '..--;~L-'.! FT,.."E:F-: ': = '1..:t. 2 THE F. IET(;i!IJIF. iED SIZE; OF THE '_:;F~IL RE:SFIF.:F'TIF~N//S~$TEM I:5: / \ lei:, F.Z F" 1-H =-: 21_ !-__:1 L_ E t'-,t IS-F H =---- 1 :Z-"-'~ ,Z.~ F-.'. F! "...' [-Z [.._ [:' E F'-]F'H =: / THE I_EI",IGTH DI't"IEI'.,IS'[C. IN 'rS ']"HE LENGTH ,::T~ F~ET::' OF EFICH S:[E:,E FOF.: FI "~;EEi;F:'F!GEi. F:'i !'. 'T'HE DEPTH F~F FI TF.:Er-,IE:H OF: PT] iS I,~,~ DT~T/~tlI'"ICE BETHEEI'.4 THE; SUF.:FRC:E OF THE; I]F:L")UI'.,I[:, F-It"4D ]'HE EI(:iTTiZir,1 i-iF THE E::-::C:Ft',,,'t~T.rOI~ ,:: .rl'..i FEET::,. ']'HE GF.':R'v'EL DEF'TH IS; THE PIIr-,,Ir'II-IH E:,EF"~,F'I ¢-,~- GF.'tR',,,'EL E:ETHEE:N THE ,T_,I_,TF:FH__L. I:::'II:::'E; t:,lqE:, 'THE E:,Z,'FI",Z,I"I C,F ]'HE E::.:iC:FI,,RT~II"A, FEET::'. E E:FiC:KFILt_.rNG ,ELF-RI'.4Y ,_:;i¢,_:.;TEHf HITHFIIJ~\ F:'II'.,~L II'.iSF'EC:TION RNE: RF'F'I4::i.-J',,,'RI_ E:'r-- l"H.r :ii; DE:F'F:IF.:Ti"'ENT !-,.IIL_L E:E SI~IE:...TEC:T~ F.:I~E'L'::L'T]:CII'-L fq.rNIHUH E:,.rb, rHNL:E E~ETHEEN H 1.4E2 FII'.~X~NY OI'.~-STTE SE:HFIGE E:,]:SF'C~:E:R1._ :::YSTEH .:I.E~E~ FEET FOF.: FI F'F.:IVRTE HELl OF.: ~C~e~ FEET FOR FI PUE,'L'rO HELL. klFJ. I_L. LOGS FIF.'.E F.:EL:.¢J'rF.:ED, FINE.', I',IUST BE F.:E]'UF.:NEE:, 1"O 'THE E:,EF'FIF.:THEI'.~'F P.I.'[TH]:!'.,I :.:.,:~!~ OF 7FIE I4E!_t.~ COHPLEET]:ON.': :SPE:C: 'r F' 'r CFtT I O1'-~ RND C:ONS'TF.:UC:T T ON E:, ;[ RGE:RI'dS FIRE FIVFI ;[ LRBLE TO 'r I'.,IS:UF.~E j[ NE;I"RLt~ FIT I ON. F' [iii: F~: I-1 :[ "'f" ' '" R L.. ]: [:" ' .... r~ I"-.I E "T' E: F~ F-: F: E." C" !"1 :]:.: ~; CC-~; IL. Il ! CE'F.:T I: FY THRT :]..: Z f'al'd FFIH]:L]'.FIF.: H]:'FH THE F.:EC..!U'rF.:EMEI'.,I]'S FOF.'. ON-S:[TE %EHE:F.:S FINE:, HEL. LS FI:.:_: FOF'.TH B',r' THE I"IUN'rC:]:F'RLTT'¢ OF FINC:HOF.:FIEiE. 2: 'r H]:LL 'rNS]'FILL THE SYSTEH ]:N FIC:C:OF.:DFII"~C:E HZTH THE cor':,ES;. :.7: 'r IJNE:,EF.".'iSTFtI'.~D -rHRT THE: ON-S]:TE; SEHEF.: '..:.;Y~TEEP1 f,lFlY F.:EL::!UIF.:E Elqt...FIF'.GEI'tEI'.4T !F 1'!.-4, E F.:ES'rE:,EI'.4C:E :['R F.:EHCE:,FLED 't'O INCLUDE I',IOF.:E THRN 4 BEE:,F.'.OOML--... FIF'F'L :1: CANT AF.:'¢ I r:, f,1 'r LLER ]::SSUE'D B' ¢_/t... ['RTE MUNICIPALITY OF A/~CHORAG~ Depal ~nt of Health and Environmenta~ Protection SOILS LOG PERCOLATION TEST Performed for Arvid Miller Date Performed Legal Description [0t 40, De]bcia Subdivision 0 6 8 l0 6/30/76 (See back for test hole location) Red,brown, sandy silt (M~) Perc rate = 275 ft.~/bdrm. Red-brown, sandy gravelo(GW) with cobbles 8 inches Perc rate: 85 ft.~/bdrm. Increase in sand from -12 to ~14 feet TD = 14~ No water table, encountered. AVERAGE PERC RATE FROM SOILS LOG = 112 ft.2/bdrm. Date Net Time Depth Net Drop Percolation Rate minute '/ / / / / / / / / / / IAI'~J_SAS 'I¥SOdSIQ IzI~.LYMq.LS"CM 3..LISNO ~ h-NJ ~' ' '-- ~".~ ' ' ,~ ..... · '' '~, .... . .' , ' .... ." '. '. , · - . -...-.::Y. 4-..h.--.t...t--';.Ll. ..... , ........ ..... .: ...... :' 'F;;' · -- ' , -- ;- : - ' ~ ' ~'' '~' 2" ' '""' ""'" '" '~. , · , ~ t I f I f"~ ".I~-"F"'~' ~':' : ....... ~_:_' '"'~ ' T'""". ........ ?''~_"-'_m'_".::, ', ::' .... ~"'~"--"q~' '."'"'l"-~~'~.'.'--~:.~.~'.'~-, · , ~ ii, . ..'!-_-7 K :! z( ' ' 0 ¢""% · ~]~ L)· · ~ .... ' ...... '! .... ' .... ';--' :.'..1 ........... ": ....... ,..-~.¢'.~::,~,,k~... :. ........ -;!:~:.:~ ~-.:.7.. :, .':.. ...... ". '.... :~.m,: ." .': .-:.. , . .. . ... N~. I.~'-'''~ -i. ' . ':: - ....r ....... ~ - '?'~7--~- ,~:5 -:"-~ .,~,,z x.:? ;i':~d:'~ c' 7 i': :' ,:: :': '- !:."- ":,.'~:.--":-¢'; :'::"-." ';:. '..=..::. ,:::="-- ' -..L: ;.,..; :.-,u .,-,~ 1 ' ! ~ . .'- , I-'-'~ · ; ,% · · .-: . -o- ........ ~ .......... v / I ~z/ ~l / I ~ ,.,I ~ I~. I~ -t ~1 ~ .~ ~[I 4 ' I ' .... ~' ~-.'.~ .... 's" "~--"I~- i'~' 'J "' ~1. --: 'I._~' · -L--rT,:~ / ~g~ - ( .~ / ~.:...~..~hl..,.,,~,.~..,¢~ :.~.,.,,'.-;., ~1 _, I .~,1 ', I --4 -_-'~ . ~'~ -~. Dc~ ~ =o~ <~ ,~c~ -;~ _~> ~ r.-I -~¢ = ~ / / '-...~[-. '-- · z-'x '- '" *: .~ " · ' ~'~'Ye '~ · 't,_..-~' J5 '~.~ I 'i';? -,,,,,r_ .~' '-~ '~,~.= ..,-~'~.-~. -%-, ..' =~t,--'.~,-~". ~'.~ '~....'. I · ~3 .~ ' ' ' '. ' =' · ' ~-~'-- = · .' ' ' --: ,~ ~, u'. ~[-- L. . ~_r..-~..,,..==,~ ~.~c=~'~,~.=_~.-'=~.= ~ , .. ~ ~ ......... · .'~;.'..j.'.". ~-'..'. -.~ .... ...~, ..:.. ~-. ~..~ ..~. ......... i ...... F ...........J .. ~. . ~ .....~ .... ?.-_.-...~ =, ~,~.,~..,,,. j . .~ ~.~'t~.'~'I~":'';~,.;''' :'~'~-~ ;:~':',',"'~ '~*"~S~., .... ~, .,~,~;,,,~;~ ~;..,~,~.,~' .. ..~.. ¥.~.~-,~,~.,r~.;Z,.~., ,.. ..~,.~., .~, t . ....¢~., . ~ .. .. -~, E=-- .....~.-~ ..... ~,~. ~.?c ~. ~ ~ . . ?= .... o .,_ ~-.'. ,--"-~ ........ ~ ..... , , p .... . )1. . ~ · ~ ~. - ' "II .I . ~'~ ......... ' m / / .% \ SCALE· yE R AS NOTED SR*D NW 1259 JUNE, 1987 DELUCIA SUBD. LOT 40 ONSITE WASTEWATER DISPOSAL SYSTEM / / / / LOCATED IN THE SE 114 SEC. 9, T15N, RIW, S.M., ALASKA '7'-. ~% . ! ~ ouue~ :~a: .... ,,.~ ONSITE WASTEWATER DISPOSAL SYSTEM REVISION ~ ~ LOCATED IN THE SE 114 SEC. 9, T15N, RlW, S.M., ALASKA UNrTED SWES K)~L SEmnCE I WMIktolXNd[M _ I :~M_ R~URN Municipality Anchora (City, Illth, m)d ZiP Code) m .D I DOMESTIC RETURN RECEIPT STICK POSTAGE STAMPS TO ARTICLE TO COVER FIRST-CLASS POSTAGE, CERTIFIED MAIL FEE, AND CHARGES FOR ANY SELECTED OPTIONAL SERVICES. (see front) 1 It you want tins receipt postmarked, stick the gummed stub on the left portion ct the address side of the aM,cie leaving the receipt attached and present the article at a post office service window or hand it to your rural carrier tho extra charge) 2 Il you do not want this recmpl postmarked, stick the gummed stub on the I¢1 portion of the address side of the ad,cie, date, detach and relaln lhe receipt, anO mail the arlicie ~, . rt' ied mad number and your name and address on a return receipt card, 3 If¥ouwantaretu'nr.~c'etpt'~w'mYnece ~- - m an~ofthe'ummedends l space permits. Otherwise, affix Form 3811, and attach it 1o the front of the amc~e o¥ e ~ r , -~-, to back of article Endorse lronl ol arhcle. RETURN RECEIPT REQUESTED adjacent ,.A the number 4 If you want delivery restricted to the addressee or to an authorized agent of the addressee, endorse RESTRICTED DELIVERY on the tront ct lhe article 5. Enter fees Ior the serwces requested in the appropr,ate spaces on the front of this receipt If return receipt is quested, check the applicable blocks in item 1 ct Form 3811 6 Save th~s receipt and present it il you make inquiry unicipality of Anchorage P.O. BOX 196650 ANCHORAGE, ALASKA 99519-6650 (907) 264-4111 TONY KNOWLES, MA YOR DEPARTMENT OF HEALTH & HUMAN SERVICES May 27,1987 Arvid and Wanneta Miller 6701 East 10th Avenue Anchorage, Alaska 99504 Subject: Development of Lot 10 Delucia Subdivision Dear Mr. & Mrs. Miller: Recently it has been brought to our attention that a well has been dug on the above mentioned parcel. After a site visit it was confirmed by our office that a well did exist and the tot appeared to be in development stages. According to the Anchorage Municipal Code Chapte~ 15.55.040, "It is unlawful for any person to construct a ground water well unless he holds a valid permit issued by the department in the name of the property owner for the specific construction proposed." In addition, Anchorage Municipal Code Chapter 15.65.020B requires, "A lot or parcel served by a well or public water supply must have a sewage disposal system conforming to this chapter, or a public sewer." To avoid further legal actions the well must be either abandoned or the proper permits for on-site septic and well installations obtained from this department. Please contact us immediately during our business hours between 8:00 A.M. and 5:00P.M. by phone at 343-4744. Civil Engineer On-Site Services cc: Gus Andress~ P.~. Water Quality/on-Sit~ Services Project Manager Jon Dunham, Code Enforcement Officer Building Safety bJ ~mm~LmJaa fJOILS LOG PERCOLATI014 TEST '/~rvtd #111er . . Date Lot 40~ I)elbcta $,_,_h~_tvtst_on ..... aed-.br~n, sandy ~11t (1~) Perc rate - 276 ft.~lbdm· S/30/TS 4 Red-brown, sandy g?ve12(b'd) vlth cobbles 8 1riches Perc rate - 8) ft, /balm. ' I0 14 Increase tn sand fron -12 to -14 feet 11) ' 14* 16 No water table, encountered. AVERA~ PERC RATE FROg SOILS LOG · 112 ft.2/bdm. Date Bet Tile _bo_th Bet 9top J ~ ~ pcrcol&t~on Rate minute Perfortned R,..~J~...~ r~'~'~' ..... ~ NORTI. rdEST EXPLORATION S£R¥ICES, INC. · m' DEPARTMENT ~' .~4EALTH AN[, ENVIF:C'NHENTAL ' i:x~.TEC T I ON · "' 2516 E. i~1~0~ RD., FtNCHOI;;AGE. AK. 9~'!s07 276-,22'2:1 ' 14ELL FIND O1'-,I-- ~c;. I TF- 5EI--IEI~'.: F'EF:I-1 I 'f PERMIT NO. ( 7'6462 ) /, APPLICANT LOCATION LEGAL AR~D MILLE~ DELUCIA SUBDIVISION L40 DELUCIA SUB STAR ROUTE B:.': 949 C:HLIGIAK 995~ 688-2597 LOT SIZE 15000 SQLIARE FEET TYPE OF SOIL ABSORBTION SYSTEM IS: PIT MAXIMUM NUMBER OF BEDROOMS = 4 SOIL RATING (SQ FT/'DR)= 112 THE REQUIRED SIZE OF THE SOIL RBSORPTION//~'~TEM IS: . DEPTH= '18 LENGTH= t9l ~RR~EL [:.EPTH= THE LENGTH DIMENSION IS THE LENGTH <II~ FI~ET> Of EACH SIDE FOR A SEEPAGE PIT. THE DEPTH OF 8 TRENCH OR PIT I~ T~E DISTANCE BETWEEN THE SURFACE OF THE GRO~D 8ND THE BOTTOM OF THE E}:CRV~TIO~(IN ~EET). T~ GRHVEL DEPTH IS THE MINIMUM DEPTH O~ GRAy'EL BETWEEN THE OUTFRLL PIF'E BACKFILLING OF AN~ S~STEM WITHOL~ FIF~L INz, F'ECTION AND 8F'F'RO,..RL BY THI:. DEPHRTMENT WILL BE SUB TEC. ~00~ R~~EC ION MINIMUM DISTHNCE BET~EN 8 WEL RHN~NY ON-SITE :,EHAGE [',ISPO~RL ~.STEH IS 100 FEET FOR 8 PRI~ATE WELL OR '.00 FEET FOR 8 PUBLIC HELL WELL LOGS 8RE REQUIRED 8ND MUST BE RETURNED TO THE DEPHRTMENT WITHIN OF THE WELL COMPLETION.' SPECIFICGTIONS 8ND CON,RUCTION DIaGRaMS ARE AVAILABLE TO INSURE PROPER I NSTHLLHT I ON. PERM I T VHL I C. ~FC~ C~E 't'E8~: F~:~]~l I I CERTIFY THAT i: I 8M FHMILIAR WITH THE REQUIREMENTS FOP ON-SITE SEWERS RN[;, HELLS ~S SET FORTH 8Y THE MUNICIPHLITY OF 8NCHO~HGE. 2: I WILL INSTALL THE S~STEM IN 8CCOR[i, ANCE WITH THE CODES. ~: I UNDERSTHND THAT THE ON-SITE SEWER SYS. TEM M~Y REC~UIRE ENLARGEMENT IF THE RESIDENCE IS REMODELED TO INCLUDE MORE THAN 4 BEDROOMS. APPLICANT ARVID MILLER