HomeMy WebLinkAboutDENALI VIEW BLK 2 LT 4Dena li View Lot 4 Block 2 #015-461-15 Municipality of Anchorage Psee / of__ DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744 On-Site Wastewater Disposal System and/or Well Inspection Report Permit Number: c~ o ~ PIDNumber: ~ Uame~.~(L~.l~//~ ~ ~ ~ Wastewater System: ~New ~ Upgrade Address: ABSORPTION FIELD I No. of Bedrooms: , Phone~- ~?~/ ~ l~DeepTrench ~ShallowTrench D Bed D Mound D Other Soil Rating: Total Depth from original grade: LEGAL DESCRIPTION ~.~ ~/s~. ~. Lot: Block: Subdiv~ion: Depth to pipe bottom from original grade: G ravel depth beneath pipe Township: I Range: I Section: Fgl added above original grade: Gravel lo th: ~-~ Ft. ~ ~ Ft. Gravel width: Number of lines: ~Oistance between lines: WELL: ~ew D Upgrade ~ Ft. ~I /~ I Ft. Classification (Private, A,B,C): Total Depth: Cased T~ Total absorption area: Pipe materisl: Yield: Casing Height Above Ground: SEPARATION DISTANCES ~Septic ~ Holding ~ S.T,E,P. TO Septic Absorption Lift Holding ~ub[ic/Private Manufacturer: Capacityin gallons: From Tank Field Station Tank Sewer Lines ~ ~ ~ Material: Number of CompaAments: Sudace Lot Size in gallons: ] Manufacturer: ~ ~ "Pump on" level at: ; High water alarm at: Remarks: BENCH MARK Location and Description: Inspections pedormed by: Department of Health and Human Se~ices approval Reviewed and approved by~~ ~/~. ~ Date: ~ / ~- ~ 79-013 (Rev. 9/91) MOA 25 .P.I~D. ND, 015-461-t5 AS-BUILT WA~T[WATER ADSORPTION $YSTEM LOT 4~ bLOCK e DENALI VIEWT : ~ : RESERVE gRE~ ~ A~'L SOILS WILL ......... ~ ............. --.--~,~ ~ ~ ~ ~ EXIST'G 3ED TYPE SEPTIC SYSTEM~ T8 3C C4 M8 EXI NEW 1,250g_ SEPTIC TANK .N..EW 4~R 23,4 26,9 30,8 31,3 32,8 32,8 45,0 43,0 57,8 91,7 57,8 90,8 68,4 58,7 71,6 102,3 69,7 100,9 4. \ \ WELL Su[" ana cive A 3 i ....... ;": ................... ' 19,4 83,3 NB~ ~ELL UR SEPTICS ~ITHIN 100' OF~ PROPOSED ~ELL PERMIT ND, SW980363 NEW SYSTEN 8 EA, 5 WIDE iNCHES 155LF TIqTAL×3* ADD'L SOILS VER DURING o ~EXI PREPARED FOR~ WiLLi~m ~ousque~ P,O, Box 111438 Amchom~ge, AK 99511 (907) 844-5951 EXIT'G PANNBNE ENG, SVC P, D, BOX 148085 ANCHORAGE, ALASKA 99514 878-8818 Phone & Fax SCALE, l'=to0' t AS-BUILT i P.I.D, ND. 015-461-15 AS-BUILT 3ETAILS WASTEWATER A]~SORPTtON SYSTEM LOT 4, ]~LOCK 8 I)£NALI VI£WT S/II Z PERMIT ND. SWgBO3G3 ° T C:\Wor k\4-2I)ENLI,]DWG PREPARED FDR~ WiIU~m Bousque~ p,n, ]~ox 111438 Anchorage, AK 99511 (907) 844-5951 PANNONE ENG, SVC, P, O, BOX 148085 ANCHORAGE, ALASKA 99514 874-0308, 878-8818 FAX ~ATEI 9-5-99 I NDT T-~-~-C--ALEL AS-~UILT From : RLPINE DRILL 90? 545 0202 Sep. 13.1999 08:58 PM P01 Rick Mystronl htr p:flwww.ci.~ nohorag e.ak.us Mayor Permit Number: #SW 980363 Date of Issue: 9-16-95 Parcel Identification Number: 0,15:461-15 Date Starte~,: 6-2, .~_ "'Date'Conlplc(cill: 1~-2-99 Is well located at approved permit Iocation?'l~' Ym ~ No Legal Description;' - ' Denali V~w-blk21ot4 PrnperW Owner~Name & Address: William Bousquet -B-orehole Data: Soil 'l'ypc, 'l'hickne. zs & Water Strata Stick-up 0 Silty gravel 2 13 Bedrock 13 165 P.O. Box 111432 Anchora..qe, Ak 9951 Depth From To H20 130 145 RECEIVED SEP 1 4 1999 Mumc~pality ot Anchorage Oept Health & Human Services · Method of Drilllng [] air rotary [] cable tool Casing type: .s~t_eel Wall Thickness: .0250 inches Diameter: ~ inches Depth: 20 fcct Liner Type: Dianlcter: __ inches Depth: ~ Casing stickup above ground: _2 feet feet Static water level (fi.om ground level): 17 feet Pumping level: 16,5,feet after ~2 hours .pmnping 4 gpm Recovery Rate: _4 gpm Method of Testing: air, lit! Well 'Intake Opening Type: [] Open End [] Open'Hole [] Screened Start __ fe~t Stopped ~ feet [] Perforations Start .-- feet 'Stopped ~ feet Grout Type: Bentonite #8 Volume: I bay~ Del)tit: Start_0 fe~ Stopped ~ feet Pump: Intake Depth feet Pump size hp Brand Name Well Disinfected Upon Completion? [] Yes [] .No Method of Disin fee:ion: .clorox _ Comments: Well Driller: Alpine Drilling & Enterprlsesr P.O. 'Box 1~10496 Anchorage, Ak 9951 t -&~ea: ~he.a~tl~.k~ell-f*ev44ea~14egle4~l~~~ &Oqk. y~.of4~ompletion and tho property Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L' Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST PERFORMED FOR: LEGAL DESCRIPTION: 2 3 4 5 6 7 8 9 10 1t 12 13 14 15 16 17 18 19 20 DATE PERFOR ~ /-. ~'~//"~ '~-'~) (~.~01~ /..I I)l'~,.2 Township, Range, Section: '15 ~ WAS GROUND WATER ENCOUNTERED? IF YES, AT WHAT DEPTH? SLOPE SiTE PLAN Depth to Water After Monitoring? Date: S Gross Net Depth ~ ¢~¢' Net Reading Date Time Time Water Drop ~l~lle~' /'z,,'~o ~ a.~_ ~ PERCOLATION RATE q~ (minutes;inch) PERC HOLE DIAMETER TEST RUN BETWEEN ~ FT AND ~1' FT COMMENTS PERFORMED BY: ~ '~:).~,*J*~/~*,'~/-~ I CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: ~ ~/'~! ? ~[~ ~ 72-008 (Rev. 4/85) Rick Mystrom. Mayor Municipality of Anchorag,e Department of Health and Human Services 825 "L" Street P.O. Box 196650 Anchorage. Alaska 99519-6650 http://www.ci,anchorage.ak.us August 10, 1999 William Bousquet PO BOXll1432 ANCHORAGE, AK99511-1432 Subject: DENALI VIEW BLK 2 LT 4 Permit # SW980363 PID # 01546115 The subject permit #SW980363, issued by this office for a single family well and/or on-site wastewater system, is due to expire as of 9/16/99. If this is a well permit and you have drilled the well, a well log must be sent to this office for documentation of the installation and to close the permit. If this is an on-site wastewater systm and a licensed Professional Engineer has inspected the installation, the original as-built inspection report must be sent to this office for review, approval and documentation. All inspection reports must be submitted within 30 days of construction completion. A new permit must be obtained from this office for a well and/or on-site wastewater system NOT installed by the expiration date. However a new permit can be issued free of charge for a second year if the application for the renewal is received on or before the date of expiration of the original permit for which a fee was paid. When applying for a new permit after the original permit has expired or for more than a second year, the fees are: $320.00 for an on-site wastewater permit and $120.00 for a well permit. If you have any questions, please call this office at 343-4744. Sincerely,_ James Cross, PE Program Manager On-site Services enc: Copy of Permit MUNICIPALITY OF ANCHORAGE Department of Health and Human Services On-Site Services Program 825 L Street. Room 502 P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-4744 ON-SITE WASTEWATER DISPOSAL SYSTEM/WATER SUPPLY PERMIT C~ ~'~t~-~c~ Initial Date Issued: Sep 16, 1998 Expiration Date: Sep 16, 1999 Permit Number: SW980363 Legal Description: DENALI VIEW BLK 2 LT 4 Design Engineer: 0062 Steven R. Pannone, P.E. Owner Name: William Bousquet Owner Address: P. O. Box 111432 Anchorage, AK 99511- Parcel ID: 015-461-15 Site Address: 008801 SULTANA DR Lot Size: 42200 SQ. FT. Total Bedrooms: 4 Permit Bedrooms: 4 This permit is for the construction of: [] Disposal Field [] SepticTank [] Holding Tank [] Privy [] Private Well [] Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DHHS at least 2 hours prior to each inspection. Provide notification by calling (907) 343-4744 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. 5. The following special provisions. Maxmium depth of excavation to be 4 feet. Engineer must verify soils are consistent outside test hole 30 foot radius. Received By: Date: 'NO. DEli TYPE SEPTIC S' FLO~ DESIGN W~SYEWATER ABSORPTION SYSTEM LOT 4~! i_DCK 2 DEN^LI VIEWT RESERVE gREA ' ~ AI)I)'L SOILS WILL PERMIT NO, SW98 SEPTIC PROPI]SED 8 EA, 5 WIDE ENCHES 78 LFx3' EXIT'G ADD'L SOILS )TIC BE VERIFIED EX] 1 ROPB~ WELL BR SEPTICS WITHIN 100' PROPOSED WELL C~\Work\4-SDENLIJ)WG PREPARED FDR~ Willic~m Bousque~ P,O, Box 111432 Anchora§e, AK 99511 (907) 244-5951 DESIGN PERC RATEi 4 N/INCH SOIL RATE, 333~F/BR ,: 4OR HOUSE i ~ i 333 SF REaU~ED ~ 8, 5-WIDE TRENCHES ........... ,~ ........ 3 EFFECTIVE IRF= O,5B ~7~" LDN~" E~CH$~ i~'~F' TDT~ PANNDNE ENG, SVC P, D, BOX 148085 ANCHORAGE, ALASKA 878-8818 Phone ~ F~x 0~TE~ S-I%-9B ~ ~ESIGN I M ° T 49~__ No. CE 8149 DESIGN DETAILS WAST£WATER ABSORPTION SYSTEM LOT 4, BLF1CK 2 DENALI VIE~/T S/D PERMIT ND, SW98 ,/ L A/ CL CS \VorR\4-~DENL!,D~/G PREPARED FDR~ ~/i~llc~m Bousque't P,D, Box 111438 Anchor(lge, AK 99511 (907) 844-5951 PANNDNE ENG, SVC, P, D, BOX 148085 ANCHORAGE, ALASKA 99514 874-0308, 878-8818 FAX OATE~ 9-11-98 NOT TO SCALE DESIGN MUNICIPALITY OF ANCHORAGE Department of Health and Human Services On-Site Services Program 825 L Street, Room 502 P.O. Box f96650, Anchorage, AK 99519-6650 ¢07) 343-4744 ON-SITE WASTEWATER DISPOSAL SYSTEM / WATER SUPPLY PERMIT Initial Date issued: Sep 16, 1998 Expiration Date: Sep 16, 1999 Permit Number: SW980363 Legal Description: DENALI VIEW BLK 2 LT Design Engineer: 0062 Steven R. Pannone Owner Name: William Bousquet Owner Address: P. O. Box 111432 Anchorage, AK 99511- Parcel ID: 015-461-15 Site Address: 008801 SULTANA DR Lot Size: 42200 SQ. FT. Total Bedrooms: 3 Permit Bedrooms: 3 This permit is for the construction of: [] Disposal Field [] SepticTank [] Holding Tank [] Privy [] Private Well [] Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DHHS at least 2 hours prior to each inspection. Provide notification by calling (907) 343-4744 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing· 5. The following special provisions. Maxmium depth of excavation to be 4 feet. Received E~~ Date: ,~/l :~7./(~, ~ Date: ~ Steven R. Pannone, P.E. Consulting Engineer (907) 272-8218 P.O. Box 142025 Anchorage, Alaska, 99514 (907)272-8218 Fax September 12, 1998 Municipality of Anchorage Dept. of Health & Human Services On-Site Services Section P. O. Box 196650 Anchorage, Alaska 99519 Subject: Lot 4, Block 2 Denali View Subdivision, Well & Septic System Permit Application Gentlemen: My firm was contacted to design a new well and septic system for the referenced lot. The lot is cun'ently undeveloped. We conducted a soils test on June 22, 1998 und monitored the water through-out the summer. The soils report and a percolation test results are attached. No ground water was encountered. Bedrock was encountered at eleven feet in the test hole. The lot is approximately 0.96 acres in size. Lot 4 slopes to the north at a rate of approximately 10 percent. The proposed installation will be located on the northern porfiun of the lot. A new 1,000 gallon septic tm~k will be installed to serve the drain fields. Double clean-onts will be installed after the tank. A flow splitter will be installed to evenly divide the effiueut between the two fields. The proposed location is greater than 100 feet away fi'om the proposed well serving this prope~ and 25 feet from the water service lines. The st~ounding wells are located greater than 100 feet from the proposed installation. Tbe proposed installation will not affect the future devehipment of the stm'ounding or existing lots. See the attached design. Please contact me at 272-8218 or 227-3522 if you have any questions about the proposed installation. Sincerely, ~.E. Attachments: [XIST'G BEll TYPE SEPTIC SYSTEM~ EXI DES-IGN W~ :TEWATER ABSFJRPTIBN SYSTEM LOT 4,;. BEBCK 2 DENALI VIEWT FLOW PROPOSED 1,000 SEPTIC PROPOSES G WELL%., Drive RESERVE AREA ADB'L SOILS WILL PERMIT NB, SW98 PROPOSED EA, 5 WISE LFx3' NCHES EXIT'6 /. NB WELL OR SEPTICS WITHIN 100' PROPOSED WELL O\WorN\4-E])ENLL])WG DESIGN ~ ~ PERO RATE~ 48iMIN/INCH SOIL RATD 333~F/BR 3DR HOUSE ~ 1,OOO SF REQUII~ED P, 5-WIDE TREI~CHE$ 3 oEFFEOTIVE, IRF= 0,58 5fl' 'EDNG' 'E~CR;"GBO' ~F'"T'dTi~E PREPARED FOR: WILLl~m Bousquet P,B, Box 111438 Anchora§e, AK 99511 (907) 244-5951 PANNBNE ENG, SVC P, 0, BDX 142025 ANCHDRAGE, ALASKA 99514 878-8218 Phone & Fax DATE, 9-11-98 I DESIGN SC^LO l'=lO0' P~I,I), ND, DESIGN ]DETAILS WASTEWATER ABSORPTION SYSTEM LOT 4, BLOCK 2 I]ENALI VIEWT S/ID M C,\Work\4-SI)ENLI,DWG PREPAREB FDR~ Willbm 3ousquet P,D, Box 111432 Anchorage, AK 99511 (907) 244-5951 PERMIT ND, SWgB L 13_ ATEI 9-11-98 ] NOT ~-0 ~-~-~LE/ ]]E$!GN PANNDNE ENG, SVC, P, D, BDX 142025 ANCHORAGE, ALASKA 99514 874-0308, 878-8818 FAX cS~eq- ~ ,T, o.~ cm Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST PERFORMED FO R ."~[~L) C'~- PERFORN DATE ~ LEGAL DESCRIPTION: 1 4- 5~ 6- 7- 8- 9- 10- 11 13- 14- 15- 16 17 18 19 20 COMMENTS Township, Range, Section: SLOPE % \ WAS GROUND WATER ENCOUNTERED? v~ C~ S L IF YES, AT WHAT O DEPTH? P E Depth t0 Water After Monitoring? '~I~T"~"( Dale: ~,/~e/~'~ SITE PLAN I j ---- ~ N Gross Net Depth to Net Reading Date Time Time Water Drop PERCOLATION RATE ~ (minutes/inch) PERC HOLE DIAMETER . TEST RUN BETWEEN '~ FT AND ~ FT PERFORMED BY: ,~,~"~(~d~,J~/~ ~ I CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: ~ J/~.c;~/~ ~ 72-008 (Rev. 4/85) Legal Description: A. WELL DATA Well type PRIVATE Municipality of Anchorage RECEI,VED_ Department of Health and Human Services APR ,1 Division of Environmental Services MUNICIPALITY OF ANC~ On-Site Services Section 825 "L" Street Room 502 EN¥1RONNENTAL SERVICES P.O. Box 196650 Anchorage, AK 99519-6650 www. ci.anchorage.ak.us (907) 343-4744 HEALTH AUTHORITY APPROVAL CHECKLIST LOT 4, BLOCK 2 DENALI VIEW Parcel I.D.: 015-461-t5 Date completed .61211999 Total depth 145 ft IfA, B, or C provide PWSID # __ Sanitary Seal Y Cased to 20 fl FROM WELL LOG Date of test 6/2/1999 Static water level 17 ft Well production 4 g.p.m WATER SAMPLE RESULTS: Coliform 0 colonies/100 mi Nitrate 4.62 mg/I Date of sample: 3/26/2000 Collected by: SEPTIC/HOLDING TANK DATA Tank Type/Material STEEL Date installed 8130/1999 Tank size 1250 gal Well Log Y Wires properly protected Y Casing height (above ground) 2 in. AT INSPECTION 6/2/t999 17 ft 4 g.p.m S.R. PANNONE Other bacteria 7 colonies/100 mi Number of Compadments _2 Foundation cleanout _Y Depression over tank _N High water alarm N/A Cleanouts Y Date of pumping Pumper NEW HOUSE ABSORPTION FIELD DATA Date installed 8/30/1999 Soil rating (g.p.d./ft2 or ft2/bdrm) 0048 System tylb~ 5-WIDE Length 155 ff Width 5 ft Gravel below pipe 3, ft Total depth 5-6 ft Effective absorption area 1336 ft2 Monitoring tube Y Depression over field N Date of adequacy test 8130/1999 Results (Pass/Fail) NEW For_4 bedrooms Fluid depth in absorption field before test DRY in Water added ...... gal. New depth ........in. Absorption rate >= If yes, give date g.p.d. Elapsed Time: ....... min Final fluid depth ........ in Any rejuvenation treatment (past 12 mo.) (YIN & type) NO (Rev. 11/99) D. LIF~ STATION Date in§iai'led .... ~' ~ "Pump on" level at __ Datum E. SEPARATION DISTANCES Size in gallons N/A in"Pump off" level at Cycles tested in Manhole/Access High water alarm level at __ in Meets alarm & circuit requirements? SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot 100.7 Absorption field on lot 112.1 Public sewer main N/A Sewer/septic service line 99 SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: On adjacent lots 100+ On adjacent lots 100+ Public sewer manhole/cleanout N/A Holding tank , 100+ Building foundation 10 Water main N/A Drainage 100+ Property line 65.4 Water service line 25+ Wells on adjacent lots 100+ Absorption field 10+ Surface water 100+ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Water main N/A Driveway, parking/vehicle storage 50+ Properly line 16.9 Water Service line 25+ Cudain drain 100+ Building foundation 40.5 Surface water t00+ Wells on adjacent lots 100+ F. COMMENTS G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and review of Munic~eal records that the above systems are in conformance with MOA HAA guidelines in effect on this date. Engineer's Printed Name Steven R. Pannone, P.E. Date 4-3-00 HAA Fee Date of Payment Receipt Number (Rev. Waiver Fee $ Date of Payment Receipt Number