Municipality of Anchorage Page I of 3
DEPARTMENT OF HEALTH AND HUMAN SERVICES
ENVIRONMENTAL SERVICES DIVISION
P.O. Box 196650 · Ai'iChorage, Alaska 99519-6650 · Telephone: 343-4744
On-Site Wastewater Disposal System and/or Well Inspection Report
Permit Number: SW990318 PID Number: 051-091-51
Name: SDinell Homes Wastewater System: ~New [] Upgrade
Address:9510 Vanguard Dr. Anch., AK ABSORPTION FIELD
I No. of Bedrooms;
Phone: 344-- 5678 FoUr ~ Deep Trench [] Shallow Trench [] Bed i'q Mound [] Other
Total Depth from original grade:
LEGAL DESCRIPTION so~, Rating: o '75 GPD/Sq. Ft. 1 1 '
Lot: 85B Block: Doub lS~bd~sion: Depth to pipe bottom from original grade: G ravel depth~neat h pipe
3'
Ft. Ft
Township: I Range: I Section: Fill added above original grade: Gravel length:
2 ' Ft. 5 0 ' Ft.
WELL: m New [] Upgrade Gravelwldth: 3 ! Number of lines: ID~stanceb¢weenlines:
Classification (Private, A,B.C): Total Depth: Cased TO: Total absorption area: Pipe material:
Private 141 Ft. 141 Ft. 800 SO. Ft. ~STM D3034 PVC
Date installed:
Driller: Date Drilled: StaticWaterLeve[; installer. 9/8/99-9/1 2/99
Sullivan Water Well 9/30/9!L 90 Ft. Spinetl Homes
SEPARATION DISTANCES ~1~ Septic [] Holding [] S.T.E.P.
From Tank Reid 'Station Tank SewerL~nesAnchor~c~e Thnk 1 , 250
Well' >100 ' >100 ' N/A N/A 7>=~q,, Matedal~teel NumberofCompartments:
TWO
Surface 100' >100' N/A N/A N/A LIFT STATION - N/A
Lot 5 ' >10 ' N/A N/A ! N/A - Size in gallons: IManufacture~-
Line
I
N/A N/A N/A "Pump on' level at: I "Pump off' leve, at: IHig" water alarm at:
Foundation
None Noted on Lo' PumpMake&Model IElectricallnspectionsperforrnedby:
Curtain
Drain
I
BENCH MARK'
Remarks: .,
LoCation and Descfiption: Back Deck;¢,iEast End
Assumed Elevation:~ 0 0 . 0 ~=~,
Inspecti0ns performed by:
Reviewed and approved by: ~~ ~ Date:/-
72-313 (Rev, 9/91) MOA25
Septic/holding tank on lot
Absorption field on lot
Public sewer main
D. LIFT STATION None on Lot
Date installed
Manhole/Access (Y/N)
High water alarm level at*
Cycles tested
E. SEPARATION DISTANCES
SEPARATION DISTANCES FROM WELL ON LOT TO:
7100'
>100'
N/A
Size n ga Ions
"Pump on" level at*
*Datum
"Pump off" level at*
On adjacent lots ¥1 00 '
>100'
On adjacent lots
Public sewer manhole/cleanout N/A
>25'
Sewer/septic service line Lift station N/A
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOTTO:
Foundation '¥5 ' Property line > 5 ' Absorption field > 5 '
Water main/service line >lr)' Surfacewater/drainage ,~00~!: Wells on adjacent lots >100
SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOTTO:
Property line > 1 0 ' Building foundation > 1 0 ' Water main/service line > 1 D
Surface water >1 00 ' Driveway, parking/vehicle storage area >25 '
Wells on adjacent lots > 1 ~ 0 '
Curtain drain None Noted on Lot
F. ENGINEER'S CERTIFICATION
I certify that I have determined t
in conformance with MOA HAA gu~ on this date.
Signature ~
Engineer's Name Michael E. Anderson.,: P.E.
Date 1 /24/00
HAA Fee $ ~
Date of Payment
Receipt Number
Waiver Fee $
Date of Payment
Receipt Number
72-026 (Rev. 3/96)*
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my
investigation of this Health Authority Approval application shows that the on-site water supply
and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms
and type of structure indicated herein. I further verify that based on the information obtained from
the Municipality of Anchorage flies and from my investigation and inspection, the on-site water
supply and/or wastewater disposal system is in compliance with all Municipal and State codes,
ordinances, and regulations in effect on the date of this inspection.
Name of Firm Anderson Engineering Phone 522-7773
Address P.O. Box 240773 Anchoraqe, AK 99524
Engineer's signature '/~-~=~* ~- ~ Date 1/24/o0
DHHS SIGNATURE
~ Approved for ¢
Disapproved.
Conditional approval for
bedrooms.
bedrooms, with the following stipulations:
Additional comments
By:
Date /- 2-.~--- O0
The Municipality of Anchorage Department of Health and Human Services (DHHS) issues Health Authority
Approval Certificates based only upon the representations given in paragraph 5 above by an independent
professional engineer ragisterad in the State of Alaska. The DHHS does this as a courtesyto purchasers of homes
and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHHS do not
conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not
responsible for errors or omissions in the professional engineer's work.
,/
LOT 85B
/
/ TH1
/
TH3.
S2J23.8 45.:0
C3J30.0 49'.3
C4~39.5 71.6
q5145.'4 40.8
N 89°59'33.E ,145.00'
Lot 85, Double G Subdivision
Permit No. SW990318
PID No. 051-091-51
Page 2 of 3
1 ."=30'
ILT
SCALE 1" = 30'
Municipality of Anchorage Page 3 of 3
DEPARTMENT OF HEALTH AND HUMAN SERVICES
ENVIRONMENTAL SERVICES DIVISION
P.O. Box 196650 - Anchorage, AK 99519-6650 343-4744
On-Site Wastewater Disposal System or Well Inspection Report
Permit Number SW990318 PID No. 051~091-51
89.8
15.7'
~ Tee
/ ~ep Tank ! 89~.6 ~
94.2
Geotextile. Fabric
9.5
Drainfield Rock
75.0 ~ 81,
.3
I,,,' I I I
50'
!
PROFILE AS-BUILT
HORIZONTAL SCALE 1" 10'
: NO VERTICAL SCALE
89,5
SULLI VAN ·WATER: WELLS..
P.O. BOX 670272, CHUGtAK, ALASKA'99567.e TELE~"HQNE 688-2759
..... -: DEPTH.
'
Lin~rTy~: · , . .
..... f~et
Pumping level: f~t after: ... hrs. pumping . ~pm. ·
Rearer Ra~e: ~ gpm
Depth: from ~ feet, to feet ..
Pump Intake Depth: ' f~et
Pdmp Size hp Brand Name ' '
Well Disinfe~ed Upon Comple~on? ."~s ~ No
commen~: .
Ddllefs Name '
ATTENTION: It is the responsibil~ of the property owner to subm tla copy of the well tog:to the proper authority, Municipality
of Anchorage; Department of-Health & Human Services and/or Department of Environmental'Conservation_ MatSu Borough:
Department of Environmental Conservation, '
~ece ved Time Jan.24 8:20AM .:..
MUNICIPALITY OF ANCHORAGE
Department of Health and Human Services
On-Site Services Program
825 L Street, Room 502
P.O. Box 196650, Anchorage, AK 99519-6650
(9O7) 343-4744
ON-SITE WASTEWATER DISPOSAL SYSTEM /WATER SUPPLY PERMIT
Initial
Date Issued: Sep 07, 1999
Expiration Date: Sep 06, 2000
Permit Number: SW990318
Legal Description: DOUBLE G LT 85B
Design Engineer: 0014 Anderson Engineering
Owner Name: Spinell Homes
Owner Address: 9510 Vanguard Drive
Anchorage, AK 99507-
Parcel ID: 051-091-51
Site Address: 021237 MC KINLEY AVE
Lot Size: 43570 SQ. FT.
Total Bedrooms: 4 Permit Bedrooms: 4
This permit is for the construction of:
[] Disposal Field [] SepticTank [] Holding Tank [] Privy
[] Private Well [] Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ).
3. The engineer must notify DHHS at least 2 hours prior to each inspection. Provide notification by calling
(907) 343-4744 ( 24 hours ). ( Not required for a Water Supply Permit only ).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
must be either: A. Open and closed on the same day.
et -/'7 - ??
B. Covered, sealed, and heated to prevent freezing.
MEMORANDUM
DATE:
TO:
FROM:
SUBJECT:
September 16, 1999
Dan Roth
Mike Anderson, P.E..~'.~¢c~.~
Lot 85B, Double G Subdivision
Permit No. SW990318
Revised Well Location
SEP 17 999
Municipality ot A ~c~orage
Dept. Health & Human Serv oes
The builder of Lot 85B, Double G Subdivision, Spinell Homes, has requested the well
location be revised to the west side of the lot. The new location is more accessible and
will prevent the removal and demolition of several trees at the original location. The
attached Site Plan shows the new location along with the 100' protective radius. A new
testhole has been placed and labeled on the plan as TH3. The log and percolation test
will be submitted with the as-built for the system.
The system is currently in place. The house has yet to be built and the well has not
been drilled. We hereby request the location of the well be revised as shown on the
attached plan. Thank you for your time and consideration with this request.
Attachment
Copy:
Spinell Homes
Attention: Guy
SITE PLAN
· soAL----'-~ ~ 7 ;;:o'
LOT 85B
TH3 ~ '
50" Lonq X 3' Wide
X. 8" Effective Depth
AbsOrption Trench
250 Gal~0n
;eptic Tank
15' utility
20' B~M
~our~,Bedroom HQme
A.C. 0RN[
Easem~
Easen ~nt
August27,1999
Municipality of Anchorage
Department of Health and Human Sei-vices
825 "L" Street
Anchorage. AK 99502-0650
Subject:
Lot 85B, Double G Subdivision
Septic System Design Permit Application
Impacts to Adjacent Properties
Dear Onsite Services Engineer:
The owners of Lot 85B, Double G Subdivision intend to construct a four bedroom home
on the lot at the location shown on the attached Site Plan. The attached documentation
details the type and size of the septic system. It a~so shows the location of the well
proposed for the lot and provides a 100' separation distance radius. We are hereby
requesting a permit to construct a well and septic system on the lot.
Testholes placed on the lot revealed poorly graded gravels underlain by silty gravel.
Percolation tests performed indicate a rate of less than 1 minute per inch in the poorly
graded gravel and 26 to 30 minutes per inch in the silty gravel. Groundwater was not
encountered during placement of the testholes nor was any noted during the monitoring
period. We have therefore designed a deep trench system for the lot The primary
trench will be placed in both the GP and GM layers. A minimum of 2' in the GP and 6'
'n the GM layer. The average absorption rate with this combination is .75 gallons per
day per square foot. The system is desic~ned on this rate. The replacement site is
entirely in the GM layer and designed for an absorption rate of .6 gallons per day per
square foot. It is, therefore, 50' long with a 10' effective depth.
The grounG surface on the lot slopes from south to north at between 6% and 7%.
Toward the north end of the lot the surface slopes dramatically to the north. At the
ground surface the absorption trench will be a m~nimum of 40' from the bluff edge.
Extending down at a 4:1 slope from the top of the trench we wil not encroach in the
slope at a distance less than 50'.
If the system s constructed in accordance with our design the following statements
apply:
The system, if constructed as designed, will have no adverse impact on the wells
in the area or those to be constructed in the future.
2. The system, if constructed as designed, will have no adverse impact on existing
septic systems in the area or those to be constructed in the future.
hot 85B, Double G Subdivision
August 27, 1999
Page Two
The system, if= constructed as designed, will have r~o adverse impact on reserved
space, either surface or subsurface, on any lots located in the area.
The system, if constructed as designed, will have no adverse impact on drainage
patterns in the area. The current drainage pattern will be maintained.
Sincerely,
Michael E Anderson. P.E.
Attachments
64,4
648
DOU~ E- ~ 'T~i~' ..oJ~c~' 7
t
92A
9/
AREA MAP
SCALE 1" = 100'
LOT 85B
50' Lonq X 3' Wide
X 8' Ef[ective Dppth
Abs6rption Trencn
'250 Gallon
eptic Tank
~our~Bedroom
Home
Alternate
A.C. DRIVE
SITE PLAN[-
SCALE 1" = 30'
15' utility
20' B~M
Proposed
· Easement
Easement
LOT 85B, DOUBLE G SUBDIVISION
DESIGN FACTORS:
SYSTEM REQUIREMENTS:
Four Bedroom System
Perc. Rate: Lt I and 26 Min./Inch
Application Rate: .75 GPD/SF
Deep Trench System
1,250 Gal. Septic Tank
8' Drainfield Rock
4 Bedrooms X 150 GPD / .75 GPD/SF = 800 SF of Absorption Area
800 SF/16 SF/ LF of Trench = 50 LF Trnch Length
Therefore: Construct a Deep Absorption Trench System With One Lateral
50' in Length with 8' of Drainfield Rock Beneath the Lateral.
Distribution Pipe in Trench Placed at 2.5' Below the Original Ground
Surface. Total Depth to be 10.5' From Original Ground Surface. Mound
Over Trench to Provide 3' of Cover. A Minimum of 2' of the Trench Must
Be in the GP Layer.
NOTE:
8I
Natural,
Backfill
Geot~tile
Fabric,
4"'Perforated
PVC (Slots Down)
Drainfield
Rock
TYPICAL DEEP TRENCH SECTION
(NO SCALE)
Grade Area Over Trench to Drain Away.
Minimum 4' From Groundwater,
Maintain 10' Separation From Lot Line.
LOT 85B, DOUBLE G SUBDIVISION
(ALTERNATE SITE)
DESIGN FACTORS:
SYSTEM REQUIREMENTS:
Four Bedroom System
Perc. Rate: 30 Min./inch
Application Rate: .6 GPD/SF
Deep Trench System
1,250 Gal. Septic Tank
10' Drainfield Rock
4 Bedrooms X 150 GPD / .6 GPD/SF = 1,000 SF of Absorption Area
1,000 SF/20 SF/ LF of Trench = 50 LF Trnch Length
Therefore: Construct a Deep Absorption Trench System With One Lateral
50' in Length with 10' of Drainfield Rock Beneath the Lateral.
Distribution Pipe in Trench Placed at 2.5' Below the Original Ground
Surface. Total Depth to be 12.5' From Original Ground Surface. Mound
Over Trench to Provide 3' of Cover.
10,
Natural.
Backfill
Geotextile
Fabric
4" Perforated
PVC (Slots Down)
Drainfield
Rock
NOTE:
3'
I I
TYPICAL DEEP TRENCH SECTION
(NO SCALE)
Grade Area Over Trench to Drain Away.
Minimum 4' From Groundwater..
Maintain 10' Separation From Lot Line.
Muni~pelit7 of Ancho~9~
DEPARTMENT OF H=-ALTH & HUMAN
~2~ "L' StreeL Anchorage. ;d~ska 9~502-0E50
SOILS LOG -- PERCOLA~ON
Spinell Homes
Lot 85B, Double G Subdivision
1
2
4
TESTHOLE NOo 1
SLOPE
I~ltl
illg
I1!1
I
I
No
PLAN
I I I t I
S~e ~it~ ~lah
I
I
'1
t
I I
I
'L
11
13
14
15
16
17-
18-
19
20
COMMEN'~.,
~o"rro,,,% OF
p~RCOLATION R~T= .
I
J I
~o
Perc. Cavity presoaked prior to testing.
I I I
-GP Layer percolates Less TE - M~.,.~ ~
-- _an, 1 __= ..... ~er~,~uL.
,M, ichael E. Anderson ~/~/g~,
~uni~paii~, of AnchomD~
D=_PARTMENT OF M=-ALTM & HUMAN S-~V~O--$
SO~LS LOG ~ P~RCOLA~ON TSST
.Spinell Homes
Lot 85B, Doubl~ G subdiyision
SLO?c
4
5
8
C:OMMSNT~
il Illk
i
I I1'1
,F Y~. AT W~*~ N/A
I
J S~e
~itk ~lah
II I
!1 I
I
I I
I I
I
'1
~t t'1 I I I-~:t, t I I
#$
Bottom of
Hog Hole
Perc.
'¢', 94-
3D
$0
$0
I I
p~OL/,.'TION ]~k"~- .~0 (~m~m:n) P=-RO HO'= DIAMET--mR ·
T~'~ RUN B~-T~r--SN ' :~' ~T AND ~ ~
Cavity presoaked prior to testing.
I I I
Michael E. Anderson
AND MUNICIPAL GUIDELINSS IN 5FF5C7 ON ?H!S DAT! DAT--'
ON-SITE WASTEWATER DISPOSAL SYSTEM
CONSTRUCTION AND MATERIAL SPECIFICATIONS
SUBJECT: LOT 85B, DOUBLE G SUBDIVISION
GENERAL:
The scope of this project includes the procurement and placement of a
new 1,250 gallon septic tank. It also includes the construction of a 50'
long x 3' wide x 8' effective depth absorption trench at the location
shown on the attached Site Plan. The total depth of the trench will be
10.5' below existing ground. The distribution piping will be placed at
2.5' below the ground. Mounding over the trench may be required to
provide the minimum protective cover. The location of the new well to
be placed on the lot is also shown on the site plan. It is essential a
minimum of 100' of clearance be maintained between the well location
and all components of septic systems on this and other lots in the
area.
Construction shall be in accordance with the approved site plan,
design drawings, Municipal Permit with any special provisions or
conditions, and all applicable State and Municipal Wastewater
Disposal Regulations.
The Contractor shall be responsible for obtaining all underground utility
locates and for the layout of the septic system and verification of the
location of all lot lines.
Unless specifically agreed otherwise, the contractor shall be
responsible for final grading areas subsequently depressed from soil
settling. Property owner shall be responsible for revegetation of
affected areas unless specifically agreed otherwise.
Contractors installing wastewater disposal systems must be certified
by the Municipal Department of Health and Human Services for
system installations. Owners installing their own systems must receive
prior approval from D.H.H.S. before beginning system installation.
SEPTIC TANK INSTALLATION
1. The 1,250 gallon septic tank must be procured from an approved
source and installed at the location shown on the plans.
A septic tank is to be constructed by a certified septic tank
manufacturer. Construction shall include two 4" cleanouts for pumping
access.
3. The septic tank shall be sufficiently bedded to prevent settling or
shifting of the tank.
4. All standpipes on the septic tank shall extend a minimum of 12 inches
above final grade.
5. Tanks installed without 4' of cover shall have a minimum of 2" of direct
burial insulation.
Lot 85B, Double G Subdivision
August 27, 1999
Page 2 of 3
A foundation cleanout shall be installed one to four feet from the
building foundation. Two cleanouts are required between the tank and
the drainfield.
7. Final grading over the tank shall be such that a positive slope exists
away from the septic tank.
DRAINFIELD CONSTRUCTION:
1. The drainfield shall be constructed to the dimensions shown on the
design. The bottom of the trench shall be within 2" of level.
Distribution piping must be placed level with perforations down atop a
level bed of drainfield rock. Rock should then be placed over the pipe
to provide a minimum of 2" of cover.
3. A silt barrier or geotextile fabric must be placed between the drainfield
rock and the natural soil backfill.
4. Monitor tubes must be 4" in diameter and installed at the locations
shown on the design. The portion below ground must be perforated.
Contractor shall verify the septic tank and drainfield are a minimum
100' away from any private water wells in the area, 150' from a Class
"C" Well or 200' from any community well.
Direct bury insulation must be placed over the distribution system if
less than 3' of backfill depth is available. Finish grade over the trench
must be mounded to prevent settlement or depressions.
7. Grade area surrounding the absorption trenches to drain away.
A minimum 2' of accepting soil is required below the drainfield reck for
a 5' wide trench. Contractor shall verify this condition prior to
placement of the reck. All pockets of unacceptable materials must be
removed and replaced.
MATERIAL SPECIFICATIONS:
1. Septic tanks must be constructed by a Municipally approved septic
tank manufacturer.
2. The following pipe materials are approved for use in septic system
installations in the Municipality of Anchorage:
Cast Iron (perforated and solid), ASTM D3034 or P.V.C. (perforated
and solid), ASTM F810 or H.D.P.E. (perforated, but not solid) and
ASTM D2662 or A.B.S. (perforated and solid).
3. Insulation shall be at least 2" thick extruded direct burial polystyrene
(Dow Chemical Co. Styrofoam HI or equal).
4. Septic tank inlets and outlets shall be fitted with watertight couplings
(Caulder, Fernco, or equal).
Lot 85B, Double G Subdivision
August 27, 1999
Page 3 of 3
5. A permeable geotextile fabric (Typar, Mirafi or equal) must be installed
between the final drain rock layer and the native soil layer.
6. All drain rock shall be .5" to 2.5" in diameter with less than 3% passing
the #200 sieve.
INSPECTIONS:
A minimum of two inspections are required by Municipal Ordinance.
These inspections must be conducted under the supervision of a
professional engineer registered in the State of Alaska. The first
inspection must be conducted after the excavation of trenches, beds or
pits and before the installation of any gravel. A septic tank may be set in
place, but may not be backfilled.
The second inspection must be conducted after the placement of the
geotextile fabric, gravel, distribution piping, standpipes, cleanouts and
insulation. No backfill should be in place at the time of inspection.
Contractor shall provide a copy of all field survey layout and construction
notes for use in preparing the certified as-built of the completed system.