No preview available
HomeMy WebLinkAboutEAGLE RIVER HEIGHTS NORTH BLK 4 LT 11A MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION ENVIRONMENTAL ENGINEERING DIVISION 825 L Street- Anchorage, Alaska 99501 Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT ~'~UPG R AD E MAILING ADJ~ ESS LEGAL DESCRIPTION · OCAT,ON DISTANCE TO: I /t¢ Absorpt~ a~ Manufacturer ~X/~ ~--/~[~ ~ ~(~ ~-~ IF HOME'DE: Inside length lLiq capacity [ngalons DISTANCE TO: We /~ / ~ Dwelling D,STANCETO: /Lengt ofeach :e? / No. of lines / ~ , Top of tile to finish grade Length Type of crib DISTANCE TO: Class DISTANCE TO: Dwell in..~ .. ~aterial IWidth Foundation~ /.,~7~. Material Nearest lot line /6/~_¢' Trencl~wid.th ! ~ ~]? inches Total Iqngt..h.~f~ line~ Material~neath tile ~'D~-,~'~ ~ ~'~i~ches NO. OF BEDROOMS PERMIT NO. No, of compartments Liquid depth PERMIT NO. Liquid capacity in gallons PERM,T NO. Dista hoe betwe,~l,iny I'~ Total effective absorption area Width __ Depth , A ~,~ , //"~ ,/~'/~ PERMIT NO. Crib diameter ¢ 'j' Crib depth Total effective absorption area Well ~ Building foundation ~ Nearest lot line I I DC I D~ille[ ~ .~l~istance to lot line ~ PERMIT NO. Building foundation I~er I,n~ I ~ptic tank t AB~orpt'on area~s' OTHER REMARKS DATE LEGAL / ~I~T]~ ANCHORAGE AREA BOi:tCGRF-ATER ANCHORAGE AREA. BORg:aU~H Department °~' E~vironmental Q,,aHt~ ,, I I I IIIIIII 3~00 Tudo~ Road ~ Pouch a '~ ] I ~ Il - I [[ ...... Anchbrage, Alaska 99~CTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM N? 909 LOCATION SEPTIC TANK: MAILING t] (..,r. ,~(,~'X (~'~ ,~c'(~j /~ I~,uF.~"c, PHONE.,~~- ADDRESS · DISTANCE FROM WELL ~'!Ot~m~/.~b LIQUID CAPACITY /(aCl~ GALLONS. NUMBER OF MATERIAL '~'/~(~ ~?~'~ L COMPARTMENTS ~ LIQUID INSIDE LENGTH -- INSIDE WIDTH DEPTH -- SEEPAGE SYSTEM: NUMBER OF PITS LINING MATERIAL NEAREST LOT LINE SEEPAGE PIT: / OUTSIDE DIAMETER OR WIDTH /~ ' DISTANCE FROM WELL (/(;'/?~/"/~/ TOTAL EFFECTIVE ABSORPTION AREA (WALL AREA) , LENGTH /~-~ ' . DEPTH BUILDING FOUNDATION ,z~ '7~ SQ. FT. TILE DRAIN FIELD: DISTANCE FROM WELL NUMBER OF LINES ABSORPTION AREA DEPTH: TOP ~ADE FOUNDATION. ~ DISTANCE BETWEE.]~-4~S'~'''~ TRENCH WIDTH /SQ. FT. LENGTH OF EACH LINE TOTAL LENGTH , OF LINkS--~ IN. TOTAL EFFECTIVE DEPTH OF FILTER MATERIAL BENEATH TILE IN. ABOVE TILE WELL: TYPE ~I ~.,/9~ . DEPTH NEAREST LOT LINE , SEWER LINE DISTANCE FROM , BUILDING FOUNDATION. SEPTIC SEEPAGE TANK , SYSTEM WATER SAMPLE. , CESSPOOL , NEAREST OTHER , SOURCES DISTANCES: ~OI/. T~-~,'~ - DIAGRAM OF SYSTEM 1 DATE J'~?~;~ z(,,. /97~ APPROVED [ HEALTH AUTHORITY PERMIT NO. DEPBRTMENT OF HERLTH 8ND ENVIRONMENTAL PROTECTION 825 ~L~ STREET, ANCHORBGE, PK. 99501 264-4?20 ON--SITF SFPIER PERr~IT 790002 RPPLICANT LOCRTION LEGBL WILLIBM MCNBLL PO BOX EBGLE RIVER Lil B4 EAGLE RIVER HTS N~. LOT SIZE 688-~261 48000 SQUBRE FEET TYPE OF SOIL 8BSORBTION SYSTEM IS~ TRENCH MAXIMUM NUMBER OF BEDROOMS SOIL RBTING (SQ FT?BR)= 250 THE REQUIRED SIZE OF THE SOIL 88SORPTION~YSTEM IS: C, EPTH= 10 LENGTI !~.':" ~ GRBVEL DEPTH= ~-~_-~ THE LENGTH DIMENSION IS THE LENGTH (IN FEET) OF THE TRENCH OR DRAINFIEL. D. THE DEPTH OF A TRENCH OR PIT IS THE DISTBNCE BETWEEN THE SURFBCE OF THE GROUND 8ND THE BOTTOM OF THE EXCAVATION (IN FEET). THERE IS NO SET WIDTH FOR TRENCHES. THE GRAVEL DEPTH IS THE MINIMUM DEPTH OF GRAVEL BETWEEN THE OUTFBLL PIPE 8ND THE BOTTOM OF THE E~CAYATION <IN FEET). RE~U I RED-' SFPT I C TFtNK S I ZE= 1000 GF~LLCI~-IS PERMIT 8PPLICANT HBS THE RESPONSIBILITY TO INFORM THIS DEPBRTMENT DURING THE INSTBLLATION INSPECTIONS OF 8NY WELLS 8DJBCENT TO THIS PROPERTY 8ND THE NUMBER OF RESIDENCES THBT THE WELL WILL SERVE. TWO (2) I~SPEC:TIO~S ARE REL-~LII~E[) BRCKFILLING OF ANY SYSTEM WITHOUT FINBL INSPECTION 8ND 8PPROVBL BY THIS DEPBRTMENT WILL BE SUBJECT TO PROSECUTION. MINIMUM DISTANCE BETWEEN 8 WELL 8ND 8NY ON-SITE SEWBGE DISPOSBL SYSTEM IS 100 FEET FOR 8 PRIVBTE WELL~ OR 150 TO 200 FEET FROM 8 PUBLIC WELL DEPENDING UPON THE TYPE OF PUBLIC WELL. OTHER REQUIREMENTS MBY APPLY. SPECIFICATIONS 8ND CONSTRUCTION DIRGRBMS ~RE AVBILABLE TO INSURE PROPER INSTBLLATION. F'ERI'.I I T EXP I RES D-,ECErdBER _?--1., ~Lg?'...~ I CERTIFY THAT l: I 8M FBMILIBR WITH THE REQUIREMENTS FOR ON-SITE SEWERS 8ND WELLS 8S SET FORTH 8Y THE MUNICIPALITY OF ANCHORBGE. 2i I WILL INSTBLL THE SYSTEM IN ACCORDBNCE WITH THE CODES. ~: I UNDERSTAND THBT THE ON-SITE SEWER SYSTEM MBY REQUIRE ENLRRGEMENT IF THE RESIDENCE IS REMODELED TO INCIUD~~THBN ISSUED B ...... DRTE__ _ Steven A. Johnson P.O.. Boy'76 Chugiak, AK 99567 Phone: 907-688-3085 SOILS LOG- PERCOLATION TEST [] SOILS LOG PERCOLATION TEST PERFORMED FOR: LEGAL DESCRIPTION: 1 2 3 4 5 6 7 8 9 Ln!- ii 10 11 12 13- /3 I< q z--~..~,l ,_ /x);ac,,.-- 14 t~, SLOPE w^s ~ROUND WATER ENCOUNTERED;) ~ 0 IF YES, AT WHAT DEPTH? DATE PERFORMED: J / ~'~ / '~ (_.~ SITE PLAN 14- 15 16 17 18 19 20 COMMENTS PERFORMED BY: : ~ C~J ¢,~x Gross Net Depth to Net Reading Date Time Time Water Drop I ~1 'si?,a _~ ~,,~ :~,~-, ~ PERCOLATION RATE TEST RUN BETWEEN ~,0 (minutes/inch) FT AND 7 FT CERTIFIED BY: 1. '~"u-,-~._DATE: I / ~ / '] ~ 72-008 (7/76) MUNICIPALITY OF ANCHORAGE  DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTIJ~{~ICIPALITY OF ANCHOR^GE 825 L Street - Anchorage, Alaska 99501 DEPT. OF HEALTH & ENVIRONMENTAL PROTECTION ENVIRONMENTAL ENGINEERING DIVISION Telephone 264-4720 OCT ~, :3 1978 DIRECTIONS: Complete all parts on page 1. Incomplete requests will not be processed. Please allow ten (10) days for processing. 1. PROPERTYOWNER I PHONE MAILING ADDRESS PROPERTY RESIDENT (if different from above) PHONE 2, BUYER PHONE MAILING ADDRESS ~.~ ~..~,..~,~., / ~,~.. 3. LENDING INSTITUTION J PHONE I MAILING ADDRESS MAILING ADDRESS 5, LEGAL DESCRIPTION ;TR EET LOCATION J ) 6. TYPE OF RESIDENCE NUMBER OF BEDROOMS /~ [] One [] Four SINGLE FAMILY ~ Two [] Five [] MULTIPLE FAMILY [] Three [] Six [] Other 7. WATER SUPPLY [] INDIVIDUAL* *ATTACH WELL LOG. A well log is required for all wells drilled ~ COMMUNITY since June 1975. For wells drilled to that date, well prior give [] PUBLIC UTILITY depth (attach log if available.) 8. SEWAGE DISPOSAL SYSTEM ~ INDiVIDUAL/ON-SITE** **If individual/on-site, give installation date / ~ 7~~-* If system is over two (2) years old an adequacy test is required [] PUBLIC UTILITY by this Department. NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED. 72~)10(3/78) ~ THIS SIDE FOR OFFICIAL USE ONL~ -... DATE RECEIVED INSPECTION APPOINTMENTS TIME TIME TIME DATE DATE DATE INSPECTOR INSPECTOR I NSP ECTOR DIRECTIONS: 1. TYPE OF RESIDENCE NUMBER OF BEDROOMS [] SINGLE FAMILY [] ONE [] THREE [] FIVE [] OTHER [] MULTIPLE FAMILY [] TWO [] FOUR [] SIX PERMIT NUMBER 2. WATER SUPPLY [] INDIVIDUAL DEPTH OF WELL [] COMMUNITY DATE DRILLED [] PUBLIC UTILITY Connection Verified LOG RECEIVED 3. SEWAGE DISPOSAL SYSTEM PERMIT NUMBER [] INDIVIDUAL/ON -SITE DATE INSTALLED []PUBLIC UTILITY Connection Verified INSTALLER []Septic Tank or [] Holding Tank Size: i(~ ~ If Tank is homemade SOILS RATING give dimensions: / TYPE OF TANK MANUFACTURER TOTAL ABSORPTION AREA MATERIAL 4. DISTANCES Septic/Holding Tank IAbsorption Area lSewer Line Nearest Lot Line WELL TO: Absorption Area to nearest Lot Line 5. COMMENTS ~ APPROVED FOR ~ BEDROOMS [] CONDITIONAL APPROVAL (letter must a/~ccon~any certificate) [] DISAPPROVED ~ ~ ___1~.,~.~// DATE ~'_ ~--~'~ BY (Title) LEGAL DESCRIPTION 72-010 (Rev. 3/78) M~CHANICAL ENGINEER DAVID MLENKAMP 694-9055 MECHANICAL ENGINEERS CIVIL ENGINEERS SRB 196X Eagle River, Alaska Department of Health and Environmental Protection Municipa%ity of Anchorage 826 L Street Pouch 6-650 Anchorage, Alaska 99505' CIVIL ENGINEER ROBERT A. SHAFER 694-2979 99577 ~UNICIPALI~ OF ANCHO~GE DE~ .~'/.f~L~ ~979 ENVIRG~ENTAL P~OTECTION ,JAN 1 lg?g RECEIVED Dear Sir: Our organization performed a sewer system adequacy test 15 and 16 October 1978, on'prOperty owned by Mr. Don Trudeau-locat%d on Lot ii-A, Block 4, Eagle River Heights North Sbudivision, Eagle River, Alaska. .Th9 results of this test indicated that the system was performing adequately and was documented by .our letter dated 18 October 1978, a copy of which was furnished your office. It iS our understanding that the present occupants who bought the property from Mr. Trudeau, is now experiencing a great deal of difficulty with the sewer system. In my brief investigation, I have found that Mr. Trudeau was having the system pumped by two different pumping companies on a regular basis and in addition, had thA system blasted during the su~aner of 1978, in violation of Municipal Ordance, this was done prior to the performance of the adequacy test. Had we known that Mr. Trudeau was experiencing these difficulties with the system, or that he had it blasted, it is doubtful that we would have accepted the results of the adequacy test without question. We, no doubt, after raviewing the test results, would have called for a repeat of the test to verify the results. We can only speculate that perhaps a fissure, as a result of the blasting, allowed a rapid percolation during the test period. This percolation does not occur at this time and a fissure if it exist may even now be a source of water entering the seepage pit. We may even speculate further that since two different pumping companies were servicing the system, water may have been inadvertly pumped out of the pit during the 24-hour period when the test was being conducted. As a result of the above findings, the system can not be considered adequate and has apparently completly failed. January 3, 1979 Bill Mc Nall Post Office Box 143 Eagle River, Alaska 99577 SubJectl Lot 11 Block 4 Eagle River Heights North Subdivision This department issued aD. approval for the sewer system serving the dwelling on the subject property. The approval was based on the adequacy test performed by Robert A. Sharer, P.E. The test shows the system to be adequate for a five(5) bedroom home, even though the request is for only a two(2) bedroom residence. It has come to my attention that the seepage pit had been dynamited approximately one(l) month prior to the adequacy test. If I had been aware of this, I would not have issued an approval. It should also be noted that dynamiting a sewer system is in violation of state and local health codes. If there are any further questions, please contact this office at 264-4720. Sincerely, Robert C. Pratt, R.S. Associate Specialist RC~/ljw 17 October 1978 MUNICIPALITY OF ANCHOR DEPT 0 AGE ENV{~-, ' /: HEALTH & ltONMENTAL PROTECTION OCT 1 9 1978 RECEIVED Hr. Don Truedall P. O. Box 4-2173 Anchorage, AK 99509 Dear Mr. Truedall: A sewer system adequacy test was performed on your two bedroom residence located on Lot llA, Block 4, Eagle River Heights North Subdivision, Eagle River, Alaska. · "~,e septic tank was pumped on 15 October 1978 and verified to be 1,000 gallons. The system consisting of a seepage pit was charged with 900 gallons of water. Percolation over a 24 hour period as recorded on 16 October 1978 resulted in the removal of 810 gallons or 405 gallons per bedroom. On the basis of the above survey and test, it is determined that this system (septic tank and seepage pit) is adequate. CF: Municipal Health and Environmental Office