Loading...
HomeMy WebLinkAboutEAGLE RIVER HEIGHTS NORTH BLK 5 LT 6Eagle River 40 Heights North Block 5 Lot 6 #050-191-14 Municipality of Anchorage Community Development Department Page 1 of 5 On -Site Water and Wastewater Program 4700 Elmore St. • P.O. Box 196650 Anchorage, AK 99519-6650 • hftp://www.muni.org/onsite • (907) 343-7904 ONSITE WASTEWATER INSPECTION REPORT Permit Number: SW080186 PID Number: 056-191-14 ❑ New ❑✓ Upgrade Nam: Audrey Mason ABSORPTION FIELD Dee ❑ 0 p Trench El Shallow Trench [I Bed El Mound Address 18540 Upper McCrary Road, Eagle River,AK 99577 ❑ Other Phone Number of Bedrooms Soil Rating Total depth from original grade 622-3344 3 6GPD(SF 9.7 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade 3.6 Ft. Gravel depth beneath pipe 1 6Ft. Subdivision Block Lot Eagle River Heights North 5 6 Fill added above original grade 4 FL Gravel length 10 FL Township Range Section Gravel width - 3Ft. Beds_ Number of Lanes N/A Distance between lines I N/AFL SEPARATION DISTANCES To From Septic Tank Absorption Field Lift Station Holding Tank Sewer Line Total absorption area 120 Fi' Number of trenches 1 Dist. between trenches N/AFt. Well NIA N/A N/A N/A N/A TANK ❑ Septic ❑ S.T.E.P. ❑ Holding ❑ Other anufact uar Anchorage Tank capacity 1500Ga . surface water 100+ ft. 100+ ft. N/A N/A Material Number of compartments Lot Line 23+ ft. 16+ ft. N/A NIA NA Steel 2 Foundation 5 ft. 10 ft. N/A NIA LIFT STATION Manufacturer Capacity Curtain Drain None None N/A N/A cal. Remarks This is an Avantex System. Pump on level at in: Pump off level at in. High water alarm at in. This tot is served by public water. "CO is PVC, MT is D3034 below stir & solid above. Pump make and model Electrical Inspections performed by Installer PIPE MATERIAL House to tank 4" ABS Tank to 3034 drainfield Dean Excavating Drainrreld D3034 cotMT See Inspector Fred Kenley BENCH MARK (Assumed elevation) 100.Oft Inspection 9/24/2008 dates: Lra 9/25/2008 e 0 Location and description Bottom of the siding on the front of the house. COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL Conditional Approval: Date��" ir+"'p a. �l, "fi r, a� '�4.4 1H .4c 00 313 T •. � ,�}}:.l. Approved IAI 0 — D3te� =/I r _ �de.Y�LK .A4� Inspection Report_1-7-12. oc Lot e 100' ead01A� CREEK SETBACK � WATER LINE REROUT r� NEW 3'Wx6'E.D.x10'L TRENCH \� -Al SEPTi AREA i THREE t � BEDDEOCE/ \� x EASMEONT 0. REr ACK 100'® ELECTRIC 8 � FR p� CREEK � � a . H . � ANEL ,A 6 l Lot 6 GARAGE / �0, Utility e,t — — — ANVIK CIRCLE _ 7L— _ I t CRIB & TANK ABANDONED IAS PER CODE I I i Lot 5 Eale River Heights North IS/D Block 7 I I DOUGLAS T. KENLEY P.E.MODuIL-1 Civil Engineer DRAWINGS #{EXOtf1lCENl. PoIV YWY�I! p111H4%i Audrey Mt n Eagle River Hts. North S/D, Block 5, Lot 6 �10840 Anvik Cir., Eagle River, AK""" --:056-191-14 " SWO80186 O°` 10/18/11 ff— DTK 01q"t FK a.,.. 1" = 30' ""°"B°` 05110 I SHEET 2 OF 5 Lot 4 �......4& l ili Douglas T. Kenley !�t �srFq 5112 (<1FOAROFESSiC*' - --------------------------------------------------- SWINGTIES r-------------- -- -------------------- j DESCRIPTION ------- ----. A ; B ;FCO 6.70' j 43.4' r----------------------------------------------- 6" PUMP—OUT ---'---------'------ :9.45' - 43.33' ADVANTEX AX20 POD 111.80' 42.7' — -- - -- -- - - --- I— 0) BIOTUBE PUMP VAULT 1 --- — 15.30' ------------- i 44.14' ':AIR AIR VENT — — ------ - 14.30' ------+ 38.61' ® i CLEAN—OUT (see note) i 18.15' 1 38.05' 1 MONITOR TUBE 22.05'132-35' 1 ®'CLEAN—OUT 32.75' 21.95' — ---- ———— ®; ELECTRIC PANEL —— i —-a 1 1 .00' 39.13' NOTE: CLEAN—OUT #6 IS NOT A DOUBLE CLEAN—OUT_ BECAUSE OF THE AVANTEX PUMP CHAMBER, A CLEAN—OUT WAS INSTALLED SWEEPING TOWARD THE LEACH FIELD. DOUGLAS T. KENLEY, P.E. eidl Engineer SWINGTIES MENORIN m • • 1M4HF1N3 "Audrey Mason 'Eagle River Hts. North S/D, Block 5, Lot 6 "10840 Anvik Cir., Eagle River, AK I p°HJYB°`056-191-14 SW080186 n"e 10/18/11 '"' DTK 01L1"6 FK I ee, NTS I"""'®E° 05110I SHEET 3 OF 5 OF At_`Ak ; * 49 T .*! Douglas T. Kenley CE4176 till►�P OFES51 ���a_�i DOUGLAS T. KENLEY, P.E. M EMaR{I M • PWiw,AYW 19N6 • ;1@)1N.1013 ° -AUDREY MASON EAGLE RIVER HTS. NORTH S/0, BLOCK 5, LOT 6 EAGLE RIVER, ALASKA 7;7"°. `10-18-1 'DTK °P ` FK NTS DRAWINGS 054— tell - SWO80186 05110. SHEET 4 OF 5 OF A 49kk !Gj,• I *: 49 TH Kent Dou y� p CE�77 ,i MONITOR TUBE – CAPPED CO –1 PIPE IS PERFORATED IN SEWER ROCK, CO -2 SOLID ABOVE. G/L 1D1.2' G/L 100.1' \ k �GA 99L GRADE G L 99.7' FROM AVANTEX— 4" DIA. PERFORATED PIPE WF� LAID LEVEL WITH HOLES DOWN. 3/4" – 2-1/2" DIA. SEWER LENTH OF TRENCH IS 10 FEET. \� SEPTIC PROFILE AS_ BUILT NTS DOUGLAS T. KENLEY, P.E. Civil Engineer NOIEMORlMBIM• HYer,.WWMM3 pOfitY.tOrd 'Audrey Wason 'Eagle River Hts. North S/D, Block 5, Lot 6 °°°"`10840 Anvik Ave., Eagle River, AK p1pry1p1BE`056-191-14 °P 05/01/12 1 am m" )TK I °R` FK I e - NTS I. 96.56' m BOTTOM OF TEST HOLE 83.7' FROM ORIGINAL GRADE PROFILE '--: SW080186 05110 1 SHEET 5 OF 5 49 TH '. Douglas T. Kenle• •: • • C -8 76 A MUNICIPALITY OFANCHOR4GE Development Services Department On -Site Water 6 Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ONSITE WASTEWATER DISPOSAL SYSTEM PERMIT Upgrade Date Issued: Sep 08, 2008 Expiration Date: Sep 08, 2009 Permit Number: SW080186 Parcel ID: 050-191-14 Legal Description: EAGLE RIVER HEIGHTS NORTH BLK 5 LT 6 Design Engineer: 0069 DOUGLAS T. KENLEY Site Address: 010840 ANVIK CIR Owner Name: AUDREY MASON Lot Size: 17731 SO. FT. Owner Address: 10840 ANVIK CIRCLE Total Bedrooms: 3 Permit Bedrooms: 3 EAGLE RIVER, AK 99577 - This permit is for the construction of: Disposal Field 0 Septic Tank ❑ Holding Tank p Privy ❑ Private Well ❑ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3, The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received By: Date: Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 Elmore Road i P.O. Box 196650 / 5 Anchorage, Alaska 99507 l� www.muni.org/onsite (907) 343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. 050 — /9/-/!j Property owner(s) Day phone G.sez- 33 yf Mailing address Zip Code Site address ioFye'4-f l-Ae Zlf, "�cGf ''J�'� %�K Zip Code 957r7 Legal description (Sub'd., Block &Lot)r'-sc� a .2dE,e s/sr, ,c�a rnr %, g..:f I,— 'Z L Legal description (Township, Range & Section) Lot Size M q51 Sq. Ft. THIS APPLICATION IS FOR (® all that apply): Absorption Field a Septic Tank Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage ❑ Number of Bedrooms m? THIS APPLICATION IS AN: Initial ❑ Upgrade [° Renewal Cl I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. (Signature of property Permit/Rush Fees: Date of Payment: or authorized agent) Waiver Fees: Date of Payment: Receipt Number: 41541.05_ Receipt Number. (Rev. 11105) Douglas T. Kenley, P.E. 9806 E. North Star Circle, Palmer, Alaska 99645 (907) 746-1073 August 26, 2008 Municipality of Anchorage On -Site Services 4700 South Bragaw Anchorage, Alaska Re: Mrs. Audrey Mason, Owner Eagle River sleights North Subdivision, Block 5, Lot 6 10840 Anvik Circle Eagle River, Alaska PERCOLATION TEST RESULTS AND GENERAL SITE INVESTIGATION REPORT This letter is a request for a septic upgrade permit on the above -referenced property. The lot, located on Anvik Circle, is approximately 17,794 square feet with a three-bedroom residence. On August 28, 2005, an inspection was made and the septic system was found to be in a failed condition. The original system was installed in August 1972, and a new septic tank was installed on October 14, 1988, in the same location as the original tank, which is under the paved driveway. Four inches of insul foam was placed over the top of the tank. The only place for an additional leach field is in the front yard in an area referred to in an Encroachment Non -Objection and Agreement signed by Wayne D. Carmony of MEA, dated August 24, 2005, stating that, "A septic system will encroach on the platted anchor easement located on the east boundary of the above parcel." (See attached copy.) The owner has had considerable problems with the septic system over the past three years, necessitating frequent pumping of the tank and crib. On August 30, 2005, a test hole was dug to a depth of 16 feet, with a perc rate of 4 minutes per inch. No water was encountered after a seven-day monitoring period. The test hole monitoring tube is still in place, and there was still no water in the tube as of August 28, 2007. The existing 1,000 gallon tank will be abandoned according to code, as well as the 18'x16', 6' E.D. crib. There are no native trees in the front yard; there is one small ornamental tree that will have to be relocated. Attached is a design package for the new system with a 1,500 gallon Anchorage steel tank and Advantex system with an AX20 Mode 1 A filter pod for up to 4 bedrooms. Municipality of Anchorage Eagle River Heights North Subdivision, Block 5, Lot 6 Page 2 The water line was relocated in 2007 as shown on the plan view, and a representative of AWWU was present to inspect the relocation. Seward Land Surveyors verified the location of the back right- hand comer of the lot line (as viewed from the front of the house) to be 3' inside Meadow Creek. On-site observation and physical survey show that there are no water wells or private wastewater disposal systems within a 100' radius of the proposed system. The proposed system will have no measurable impact on surface or sub -surface drainage, or on drainage from adjacent lots. It appears that there is no potential for contamination of adjacent water wells or streams from known sources. Also, the proposed development will not prohibit future development of any neighboring lots. If there should be any questions, please call me at (907) 746-1073 or 243-5372. Sincerely, Douglas T. KenleyJP PE#8176 I Lot 11\, Lot 12 ; Block 1 Meadow Brook S` -p;�( WATER LINE REROUTED EW 3' W x 6' E.D. x 10' L TRENCH —, i I THREE � BEDROOM � RESIDEN& DOUGLAS T. KENLEY, P.E. CIO Enginew MMS EAGLE RIVER HTS. NORTH S/D. BLOCK 5. LOT 6 EAGLE RIVER. ALASKA '"`'""• 050-572-37 \ Lot 6 Lot 7 y" Lot 8 ANCHOR EASMENT / I j —/ `\ '---- 'ANVIK CIRCLE I Lot 4 Lot 3 9-04-081--" DTK I— FK I— 1' - 50' 1"'-- 05110 DRAWINGS SHEET 1 OF 5 .W C2 *: 49 TH ;* Dou s T. Kenley �00 l� qFC •, CE -8176 E-8176 �4�i v Lot 6 GARAGE 10 LTtip EOSemeO _ EXiSTIFC--1B00-6AL.-LnN _ NEW AVANTEX SYSTEM - 1 Lot 5 POWER POLE TELEPHONE BOX BIC�Ck 7 EXISTING CRIB CRIB & TANK TO BE AS PER IABANDONED Eagle River Heights North , I DOUGLAS T. KENLEY, P.E. CIO Enginew MMS EAGLE RIVER HTS. NORTH S/D. BLOCK 5. LOT 6 EAGLE RIVER. ALASKA '"`'""• 050-572-37 \ Lot 6 Lot 7 y" Lot 8 ANCHOR EASMENT / I j —/ `\ '---- 'ANVIK CIRCLE I Lot 4 Lot 3 9-04-081--" DTK I— FK I— 1' - 50' 1"'-- 05110 DRAWINGS SHEET 1 OF 5 .W C2 *: 49 TH ;* Dou s T. Kenley �00 l� qFC •, CE -8176 E-8176 �4�i Lot 12 ; Block 1 Lot 7 Meadow Brook S/ NOTE:ARER WHERE LEACH FIELD & TANK \A\RE IS ESENTIALLY LEVEL. i WATER LINE REROUTEd\ / ANCHOR EASEMENT EW 3' W x 6' E.D. x 10' L TRENCH �o0 - THREE I BEDROOM RESIDEN& I ' OT. H. I� Lot 6 GARAGE 16 Utility Easement — \_ - — �ANVIK CIRCLE EXIS�IITG-1 000--GAL.-'LANK _ _ NEW AVANTEX SYSTEM �i Lot 5 POWER POLE \ TELEPHONE BOX I BI ICk % EXISTING CRIBI Lot 4 i CRIB & TANK TO BE ABANDONED AS PER CODE I Eagle River Heights North IS/D 1 I I DOUGLAS T. KENLEY, P.E. CiA E.9".. .LYOIIW.- h1.w. NM.I . pM'.L AUDREY MASON EAGLE RIVER HTS. NORTH S/D, BLOCK 5. LOT 6 EAGLE RIVER, ALASKA "0`` 050-572-37 "" 9-04-08 " DTK p1u" FK " 1- � 30' DRAWINGS 05110 1 SHEET 2 OF 5 OF'At.gIII *�49 THS*��// I Douglas T. Kenley l) 9i CE -8176 ��i SEPTIC SYSTEM SPECIFICATIONS: 1. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE LASTEST EDITION OF THE HEALTH AND HUMAN SERVICES CONSTRUCTION SPECIFICATIONS FOR TRENCH & DRAIN FIELDS 2. EXISTING TANK & CRIB TO BE ABANDONED AS PER CODE. A NEW RESIDENTIAL AVANTEX POD, TANK & LEACH FIELD TO BE PLACED IN NEW LOCATION. 3. SERVICE LINE TO DRAIN FIELD SHALL BE 4" DIAMETER SOLID PIPE. 4. DRAIN FIELD LINE SHALL BE 4" DIA. PERFORATED PIPE. INSTALL PIPES LEVEL WITH PERFORATION HOLES DOWN. 5. PROVIDE 10 FT MINIMUM SEPARATION BETWEEN EDGE OF TRENCH AND FOUNDATION. 6. PROVIDE 10 FT MINIMUM SEPARATION BETWEEN SEPTIC SYSTEM AND PROPERTY LINE. 7. PROVIDE 100 FT MINIMUM SEPARATION BETWEEN SEPTIC SYSTEM. WELLS & SURFACE WATER. DEEP TRENCH CALCULATION: SOIL TYPE: SANDY GRAVEL (GW) PERCOLATION RATE: USE 4.0 MIN. PER INCH. (6" PERC HOLE DIA.) APPLICATION RATE AR): 6 GAL./DAY/SF. (EFFLUENT APPLICATION RATES) 15.65.350 DESIGN (3) BEDROOMS: ® 150 GAL. PER BEDROOM = 450 GALLONS ABSORPTION AREA = 450 CAL./DAY =75 SF. 6 GPD SF. TRENCH LENGTH = f X6 = 6.25' (USE 10'). • ASSUMES DOMESTIC WATER USAGE FOR RESIDENTIAL HOME COMSUMPTION. • CALCULATION METHOD OBTAINED FROM MUNICIPALITY OF ANCHORAGE "WASTEWATER DISPOSAL CODE REGULATION" FEBRUARY 14, 2003; CHAPTER 15.65.060 NOTE: FOR APPLICABLE EXCAVATION, TRENCHING, AND SHORING SAFETY STANDARDS, CONTACT THE STATE OF ALASKA, DEPARTMENT OF LABOR, OCCUPA— TIONAL SAFETY AND HEALTH COMLIANCE CONSULTATION, AND TRAINING DIVISION OF LABOR STANDARDS AND SAFETY AT 264-2599 OR 264-2597. DOUGLAS T. KENLEY, P.E. Ca E"9;".., xx.rx.rwru. r.r.ruru • x.n rwxn AUDREY MASON EAGLE RIVER HTS. NORTH S/D. BLOCK 5, LOT 6 EAGLE RIVER, ALASKA - • 050-572-37 ` 9-04-08 `•"VP DTK — FK I ' N/A CALCULATIONS 05110 1 SHEET 3 OF 5 OF.AGN ' TH*. 40.1 Dou Is . Kenley F� CE �I�Ea ROFESSIOHA�� MONITOR TUBE — CAPPED PIPE IS PERFORATED IN SEWER ROCK, SOLID ABOVE. BACKFILL TRENCH WALL SLOPES WILL VARY — 141TH SOIL TYPE AND MUST CONFORM TO SAFETY STANDARDS, SEE SHEET NOTE BELOW. 4" DIA. PERFORATED PIPE — LAID LEVEL WITH HOLES DOWN. SIDEWALL OF TRENCH — 3/4" - 3" DIA. SEWER ROCK LENTH OF TRENCH IS 10 FEET. j -u x WIDTH OF BACKHOE BUCKET CO -1 CO -2 n SEPTIC SYSTEM SECTION DESIGN NT$ DOUGLAS T. KENLEY, P.E. Ci.1 Engineer • Lew ru. rr...u... wws . WnIWx "r AUDREY MASON ` EAGLE RIVER HTS. NORTH S/D. BLOCK 5. LOT 6 EAGLE RIVER, ALASKA "D""" 050-572-37 "n 9-04-08 "•" DTK FK ` NTS FILTER FABRIC .2" .6" DRAWINGS 05110 1SHEET 4 OF 5 ORIGINAL GRADE 3' 6'-0" 4'-0"I MIN. 6'- 2'-0"I MIN. BOTTOM OF TEST HOLE 16' FROM ORIGINAL GRADE OF• AL,4 1 i * 49 TH� * �� / Doug as Kenley o CE -8176 Ilk \Gv RO S`0 `-Z- DI 0 SOILS LOG - PERCOLATION TEST TEST HOLE #1 �o m ti a q a q K SEE ATTACHED SITE PLAN DEPTH TO GROUNDWATER DATE 0 8/30/05 0 9/07/05 0 8/28/07 DATE READING TIME NET TIME (MIN.) WATER LEVEL READING (IN.) NET DROP (IN.) 8/30/05 1 1:40 p.m. ----- 8 ----- 1:50 P.M. 10 5-7/16 2-9/16 • 2 1:52 p.m. ----- 8 ----- 2:02 p.m. 10 5-1/2 2-1/2 • 3 2:05 p.m. ----- 8 ----- • 10 5-1/2 PERCOLATION RATE 4.0 (MIN./IN.) PERC. HOLE DIA. 6• (IN.) TEST RUN BETWEEN 6 FT. AND 6-1/2 FT. PRESOAKED FOR FOUR HOURS YES V NO COMMENTS: BENCH MARK: BOTTOM OF SIDING ON FRONT OF HOUSE 100.0• PERFORMED BY: FRED KENLEY I, DOUGLAS T. KENLEY, CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE & MUNICIPAL GUIDELINES IN EFFECT. DOUGLAS T. KENLEY, P.E. ow E,;l . r MMIMgIMfM. I•Y�.YY•MN . pM1KNT w"`AUDRCY MASON "" EAGLE RIVER HTS. NORTH S/D. BLOCK 5. LOT 6. EAGLE RIVER, ALASKA 1`4 050-572-37 `` 8-15-07 ""' DTK `"" FK I "•" N/A PERC TESTS 05110 1 SHEET 5 OF 5 qE 0F• At,gs� * 49 TH of 00.1 / Douglas T. Kenley l� 9ac • • CE -8176 �� i ��'1;;\\\ S`QO`--V=im AdvdnTdx®instailation EXAMPLE SYSTEM CONFIGURATION MODE 1A This is the most typical system configuration with the filter located above the tank and the filtrate gravity feeding to the drainfield. Mode 1B would be similar with the addition of a pump basin downstream of the tank should there be a need to pump up to a drainfield. For more Information on Mode 18, see page 39. ENCROACHMENT NON -OBJECTION AND AGREEMENT THIS AGREEMENT, made and entered into this day of A 2005, by and between MATANUSKA ELECTRIC ASSOCIATION, INC., an Alaskan non-profit member owned electric cooperative, whose post office address is Box 2929, Palmer, Alaska, 99645, hereinafter called "MEA", and BKB LLC whose address is 18540 Upper McCrary, Eagle River, Alaska 99577 hereinafter called "Applicant", Property Description Applicant is the owner of the property described as Lot 6, Block 5, BLOCK 5 EAGLE RIVER HEIGHTS -NORTH SUBDIVISION, located in T14N, R2W, Section 12, S.M., according to Plat 71-220, Anchorage Recording District, Third Judicial District, State of Alaska. Encroachment(s) Description A. A septic system will encroach on the platted anchor easement located on the East boundary of the above parcel. NOW, THEREFORE, for and in consideration of their mutual agreements MEA, for itself, its successors and assigns, waives its objections to Applicant's encroachments as described in the paragraphs above, subject to the following conditions: Applicant shall indemnify and hold MEA harmless from liability for any injury or damage to any person or property which may result from said encroachments. 2. The Applicant fully understands and agrees that this encroachment agreement does not restrict or limit the current or future ability of MEA to fully enjoy the benefits of the easement for any and all utility purposes that it presently enjoys under the easement. 3. Applicant stipulates and agrees that it shall hold MEA harmless from liability for any and all damages to the encroachments that may result from the existing and future use of said easement by MEA, its contractors, successors, agents, licensees, or assigns. 4. Any facilities or property of MEA that are damaged or destroyed as a result of such encroachment(s) shall be repaired or replaced at Applicant's expense. 5. Applicant shall comply with all applicable safety codes and regulations. 6. Any expenses which MEA may incur in the relocation or modification of its facilities to accommodate the encroachment(s) shall be paid entirely by Applicant. 7. This Agreement shall not be construed to give Applicant permission to add new structures or appurtenances or modify existing structures or appurtenances that are or will be located within the easement. Encroachment Non -Objection and Agreement Page 2 By its execution of this Agreement, Applicant agrees: (a) for itself, its successors and assigns, that its encroachment upon the named easement as hereinabove mentioned will be subject to the foregoing conditions, and (b) Applicant shall within 60 days of the date first listed above, record this document in the proper recording district and shall provide MEA notice of such recording by providing MEA with a certified copy of the recorded document. Should Applicant fail to comply with this recording and notice requirement, this agreement shall become null and void. IN WITNESS WHEREOF, the parties have caused this Agreement to be executed by their duly authorized representatives and agents as of the day and year first above mentioned. MATANUSKA ELECTRIC ASSOCIATION, INC. \\ (MEA) BY: K) 2N w:b GXJ­",�.� cam' General Manager or his Represe tative STATE OF ALASKA : SS. THIRD JUDICIAL DISTRICT : The foregoing reement was acknowledged before me this _day of f� IAT_, 20 CIS STATE OF ALASKA THIRD JUDICIAL DISTRICT a�. 0A Notary Pubic forlhe State of Alaska My comm ion expires: jar a001 APPLICANT _ BY: : SS. The foregoing agreement was acknowledged 4 before me this � day of Notary P lic foethe State of Alaska My comm' sion expires: r0evcA 1&, ao0e) RETURN TO: MEA, P.O. BOX 2929, PALMER, ALASKA 99645 ADVANCED WASTEWATER TREATMENT SYSTEM MAINTENANCE AND REPAIR AGREEMENT MEMORANDUM OF UNDERSTANDING BETWEEN M 3NIC1 ALITY OF ANCHORAGE AND THIS MEMORANDUM OF UNDERSTANDING made and ent ed into as ff this Day of of 20(2Lrby and between l I //llLOti1. herein the "OWNER," and the Municipality of Anchorage, herein the "MUNICIPALITY." In consideration of the mutual covenants contained herein, the parties to this Memorandum of Understanding agree as follows: 1. ADVANCED WASTEWATER TREA I'M ENT SYSTEMS. Municipality grants permission to Owner to utilize and operate an Advanced Wastewater Treatment System (AWWTS), described as ej located at Id SY1 �/� ��CY/ _ f chorage, Alaska. ESI.. R�•,�. If���h ,v.�rf, a 5 �.6 2. Definitions. A. Alteration. Any change to the design or function of an AW WTS that Includes the installation or removal of any parts, components or pieces not included in the original construction permit and design. Prior to performing any alterations to an AW WTS the owner must obtain a Wastewater Disposal System Construction Permit from the Municipality pursuant to Anchorage Municipal Code (hereinafter, "AMC") 15.65. B. Certificate of On -Site Systems Approval. An approval by the Municipality of existing water and wastewater disposal systems given at the time of property sale and title transfer in accordance with AMC 15.65. These approvals certify that the systems are adequate for the homes that they support and meet the codes that were in place at the time of system construction. C. Damage. Any man-made or natural change in a system that would inhibit the system from performing as designed. D. Maintenance and Repair. The scheduled and as needed replacement of existing parts, components and pieces of an AW WTS that were included in the original design which would allow the AW WTS to continue to perform as designed. E. Permit (Construction) An On -Site Wastewater Disposal System Construction Permit as defined b3 AMC 15.65. F. Permit (Operating) An Advanced Wastewater Treatment System Operating Permit. An annual permit, issued by the Municipality, that allows the Owner to operate an A W WTS, upon meeting all the requirements of this agreement, the conditions of Operating Permit, the requirements of the On -Site Wastewater System Construction Permit and all relevant provisions of AMC 15.65 3. Fee. Owner shall pay to Municipality an annual fee of 0—- (s <:C�-00), payable on or before the issuance of the operating permit and annually thereafter. The annual fee is due on or before the anniversary date of the approval by the Municipality of installed system. 4. Term. The term of this Memorandum of Understanding shall be for the life of the A W WTS. The term begins on the date of approval by the Municipality of the installed system and shall continue while the AWWTS system is in use or operational or until the property is sold or title is transferred by owner and a new certificate of On -Site approval is issued to the new owner or transferee of the property. 5. Alterations, Installation and Removal of Additional Equipment. Owner agrees not to make any alterations, removal of parts or additions to the AW«'TS without a Construction Permit from the Municipality. 6. Maintenance and Repairs. A. Throughout the term of this Memorandum of Understanding, the Owner shall maintain AWWTS in good repair. In addition, it shall be the responsibility of the Owner during the term of this Memorandum of Understanding, and any extensions or renewals thereof, at the owner's sole expense, to pay for any and all: (1) repair(s), (2) maintenance, (3) adjustment(s), (4) replacement costs, and (5) inspection costs. Further, Owner agrees to comply will all applicable ordinance, laws, regulations, rules and orders for the AWWTS. D. Owner agrees to provide the Municipality a written schedule of routine maintenance and repairs which have been performed on the system pursuant to the terms and conditions contained in the Owner's AWWTS Operating Permit. This schedule shall be submitted to the Municipality tmnually upon the renewal of the permit. The schedule ofW maintenance and repair contained in the Owner's AWTS �/ Operating Permit is: , 1;wV�l C. Owner acknowledges that the fine schedule for failing to maintain and repair an AWWTS are codified in AMC 14.60. D. Owner agrees that only maintenance, repair personnel certified by the Municipality will inspect and make any neceisary maintenance, repairs or permitted alterations to the system. E. Owner agrees to grant the Municipality reasonable access to test and inspect the AW WTS upon 24 hours written notice. F. Owner agrees that any sale or transfer of title of the property will not occur without a new Certificate of On -Site Systems Approval. G. Owner agrees that the relevant provisions of the standard specification guidebook for AW WTS is the governing professional guidelines for the construction, maintenance and repair of the Owner's AW WTS. 7. Nonwaiver. The failure of either party at ani time to enforce a provision of this Memorandum of Understanding shall in no way constitute a waiver of the provisions, nor in any way effect the validity of the Memorandum of Understanding or any part hereof, or the right of such party thereafter to enforce each and every provision hereof. 8. Amendment. A. This Memorandum of Understanding shall only be amended, modified or changed by a writing, executed by authorized representatives of the parties, with the same formality of this Memorandum of Understanding was executed and such wTiting shall be attached to this Memorandum of Understanding as an amendment. B. For the purposes of any amendment modification or change to the terms and conditions of this contract, the only authorized representatives of the parties are: Owner: Anchorage: C. Any attempt to amend, modify, or change this contract by either an unauthorized representative or unauthorized means shall be void. 9. Jurisdiction: Choice of Law. Any civil action arising from this Memorandum of Understanding shall be brought in the Superior Court for the Third Judicial District of the State of Alaska at Anchorage. The laws of the State of Alaska shall govern the rights and obligations of the parties under this Memorandum of Understanding. 10. Severability. Any provisions of this Memorandum of Understanding decreed invalid by a court of competent jurisdiction shall not invalidate the remaining provisions of the Memorandum of Understanding. STATE OF ALASKA THIRD JUDICIAL DISTRICT MUNICIPALITY: By: Title: Date: ) ss. The foregoing instrument was acknowledged before me this Aay of St�'Taraldl Y. 20�, by�..�✓a v /-fps �.,. Ile N&49fyl13LIC FORA ASKA' My Com 'ssion expires: li R+ �01A,pN �i Oc MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND HUMAN SERVICES �%S d /9/ Environmental Health Division 825 "L" Street, Anchorage, Alaska 99502, Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Name 9s77 t.�r-�/}CE PurrPH REY DISTANCES FROM TO SEPTIC TANK ABSORPTION FIELD WELL AddressEH64C- 108yp ANVIll C(arli � RrvER WELL Nr �.• N, �,. Phones, —. 2 7 / - S7s'6 Permit No. 19 -oZ z9 No. of Bedrooms 3 LOT LINE No. of Compartments 2 LEGAL DESCRIPTION Lot 'lir Block Subdivision G/4GLE R, lfle-li T -r Konr Iy FOUNDATION ❑ TRENCH ❑ BED ❑ W. DRAIN ❑ OTHER Township, Range, Section VI U w/ 3 k/ _ 6C, 1.2. 7 �`I AS -BUILT DIAGRAM (Show location of well, septic system, property lines, foundation, tli. water bodies, etc.) TANKS M Depth to pipe bottom fromlot�pth original grade FTS from ongmal grade FT Y SEPTIC ❑ HOLDING 41 Manufacturer Anchoill Tart k Capacity in gallons 1000 Material V 5hef No. of Compartments 2 TYPE OF SYSTEM awc her ❑ TRENCH ❑ BED ❑ W. DRAIN ❑ OTHER M Depth to pipe bottom fromlot�pth original grade FTS from ongmal grade FT RII added above m ginal grade _ FT Gravel depth beneath pipe _ FT Gravel length FT local absorption area SQ FT _ Gravelidth w FT i Distance between lines FT 1% O S Fh NEW Im Number of fines Soil rating SQ FT Pipe material 14 ill Plittr D -3C3'/ Installer — Date Installed. of Cons 10 / /,y Ili WELLS Pkf3l wi}Tl'I� ❑ PRIVATE ❑ OTHER (Identitvl Classflcat,on (A,B.Cj - --- 7o(al Depth FT Cased to FT Inst2 tloi Date Insta�letl: �. f0'mToF ov�R REMARKS:Ak rnr'/al/col rn Same laec 1T&17 rrevcow */'FAJ tTgd 4n ( led cl/in Intel- Ao( cetirA aIpele i/neJ �+IoCC �ycc�litnc2 tffi'+�i Scale: _ ."l _, l> 7G^ ey4o'l }tom aar ntk(/S el Inspections Performed by. 0/7 man ho/e Cavttl� 41" t -Ts pti a�s8�'� !R = 30c i Clul �bQ�m Hv }fit ecl ple -i o ar %/ Da�\ Aa' �. Sep S nder .w p weo cy awowci ,o&//yalg8 burred If b_e_�� �aunv( tut/ �n�lr' r � C 19 os" —" �— certify that this inspection was performed according to all Municipal and State guidelines in ellecl on this date: Ll I -OL9 Urn o f ! — Health Department Approval: Date. 0-2y g 79-013 l3iR9 r 1 115-4s ENGINEERS SEAL 41 M MUNILIPALITY OF ANCHORAGE Department ot Health to Human Services 825 L Street, Anchorage� Alaska 99501 343~ ON-SIlE SLPTIC lANK PERMIT Pe.^� � � `ber: 880229 Upqrade Date Issui.2d: 10/)2/S8 Day Phone: Ownei idr=ss: 10840 ANVIC ClR, 271~5/58 EAGLE AK 99577 Parcp| Id: 191~l4 Loi |^`ial: Subdivision: EAGLE RIVER HTS" N Lot: 6 Block: It Section: 12 Township: 14N Ranqe: 24w 17/31 (sq.it' or acres) `.'�s: HAS Permit: 3 Total Capacity: 3 Minimum Wtal sepLic tank capacity: 1,000 ga]lons. Each septic !"nk must ha"e a� !east 2 comparLmentmi. Depth to top of septic tank(s) < 4.0 'eeL 'quires 3nsu1atjon over tanki�s)" .—`[ALL H||HCHED PLHN" [HI� PERMl| EXPIR�S 12/�y1/88" � �m �ami1iar with �he r�quirementc for on~site sewers and wel1s as set 1h by the Municipality o[ Anchorage MOA) and the State of Alaska. C2. } w1.11 inY.1.11 the sYstem in accordance with all MOA cOdes and Pegulations, and in comp1iance with tKe design criteria of this permit^ �. I will adhere to a1] MOA and State of Alaska requirements for the set back disLances irom any exisLinq well, wastewater disposal system or public spw�-age system on this or any adjacent or nearby lot. �. I u//de,sfand that this permit is valid 1or a maximum of 3 bedrooms. I YM: understand that Lhe capacity of the total system is 3 bedrooms and ''.largement will require an add1tional permit" DATE: h i.413. DATE: -4~~-r-------- 130' i -o T 6 E: mc r1 N it 3-l3DRM }Foos E OF. A4 44 (►.THEODORE F. MOORE ; At `` Q F CE - 3589 ,&,W �. *..1 . `CI ``f�= $.�.�` Pr46F (SIT 26' GAR. SEPnc TI}N K C7o 13EREP�Ae��) DRIvFWAy SEPTIC VAN dr R E P1•,+C ErrE N r Nares': 1, -the eAfslyn colla p.eerl (o CPO gaIto r 5 f ecl see WC /CU 17 k u 1C, be pVwnpeoj m reoved and replaced wt/;► cc new 1000 crut(on 2v Comparb",en/ steel sefl* jan k:, In f*e same locuk'o-7. 2. G.rne-r Con/Iccly7 Me /.anlr �o fAe howC ctnd exufs��// 7 -cell e p.f sA4rl 4e C lean eve aXoC ne conIV ec�ed ,(, bfle nein %teak• wrk I;rcrer sloee 3. 2'r bu.rct f %ee 1ASu(u/Ta? Shall e plated over fife new funl- and Cetir►nec 41 heAwe b«ck-.r// once ►'�e�avrn Cl.eanauf cuff s4etfl be mounfcvC urh c p raaemenf 14t4VIK CIRCLE 1.0-r6, C31 -OC -ft S- C- A Cr I- EAG -I- E RIVER HTS. NoRTIf S f TE PI -A N p Are : 10111169 0 W ri 13 r: T -F n P1or : Thcr is nc4 a s ecrvered (af, 6« 1 nS %CacC i r baled on "e- excr fr sep 14c s ys Arm at IA ee&V6 A(I laCCtl ro4f are GAAS-HD I - GR ^'ER ANCHORAGE AREA BOROL 1 DErARTMENT OF ENVIRONMENTAL QUALII v 3500 TUDOR ROAD ANCHORAGE, ALASKA 99507 279-8686 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM NAME G 4300 � I CCI � ��5 ADDRESS Q � : ' LS -.-I n�y/1'' PHON�y LOCATION Eaq U>gx_� PTh1 LEGAL DESCRIPTION 61 SEPTIC TANK: ���� NUMBER OF DISTANCE FROM WELICDM IlILmi� �r=MATERIAISLOU S�t�nt lc) COMPARTMENTS LIQUID CAPACITY EEPAGE SYSTEM NUMBER OF P LLONS. INSIDE LEN SEEPAGE PIT: OUTSIDE DIAMETER INSIDE WI LIQUID DEPTH - WIDTH /Z // , LENGTH /e'L/ , DEPTH_ 1nl, LINING MATERIAL . DISTANCE FROM WELL mcb.)rAC^ , BUILDING FOUNDATIONSdZ, NEAREST LOT LINE Z I TOTAL EFFECTIVE ABSORPTION AREA (WALL AREA( 0 SQ. FT. TILE DRAIN FIELD: DISTANCE FROM WELL NUMBER OF LINES ABSORPTIO AREA DEPTH: TOP OF TILE TO FINISH GRADE FOUNDATIO CE BETWEEN LINES =NGTH OF EACH LINE NEAREST LOT LIN TRENCH WIDTH TOTAL LENGTH OF LINES_ AL EFFECTIVE DEPTH OF FILTER MATERIAL BENEATH TILE IN. ABOVE TILE WELL:DISTANCE TYPE �Frl1A1 im 1�"J0IZVH FROM , BUILDING FOUNDATION. WATER SAMPLE , NEAREST LOT LINE NEAREST , SEWER LINE SEPTIC SEEPAGE , TANK , SYSTEM , CESSPOOL OTHER , SOURCES_ DISTANCES: DIAGRAM OF SYSTEM DATE %!� / / APPROVEDTJ`�nF G.A.A.B. GR`—TER ANCHORAGE AREA BI HUGH .oKPARTMENT OR ENVIRONMENTAL QUALITY 3000 TUDOR ROAD POUCH 6.630 ANCHORAGE. ALASKA 99502 TELEPHONE 279.0686 SEWAGE DISPOSAL SYSTEM — APPLICATION AND PERMIT PERMIT NO. ---- NAME OF APPLICANT -,'-�+ �1� /"1C� �G �PC� w 4 `C „�'� MAILING ADDRESS PHONE 61:61--L z INSTALLATION LOCATION ���Y's.S. ' 1 of.•�) LEGAL DESCRIPTION ,�4 INSTALLATION OF: SEPTIC TANK_,� �1 �Z�� SEEPAGE PIT DRAIN FIELD OTHER TYPE AND SIZE OF FACILITY TO BE SERVED z -r7 I fx 14v. FINANCED THROUGH TO BE INSTALLED BY SOIL TEST.RESULTS NOTE# THIS PERMIT IS NOT VALID WITHOUT 801L TEST COMPLETION DATE ANTICIPATED FINAL INSPECTION# 94 HOUR NOTICE REQUIRED. BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION MY THE HEALTH DEPARTMENT AUTHORITY WILL BE SUBJECT TO PROSECUTION. SEPTIC TANK SIZE�rT_S4'(5 TYPE !:E3k-kIQ-t- f SEEPAGE AREA SIZE �' X/-� I TYPE L -fl i'l, r;(, MINIMUM DISTANCES, REQUIREMENTS DIAGRAM OF SYSTEM FOUNDATION TO SEPTIC TANK FOUNDATION TO SEEPAGE PIT DRAIN FIELD SEPTIC TANK TO SEEPAGE PIT WALL SEPTIC TANK SEEPAGE PIT DRAIN FIELD TO NEAREST LOT LINE. WELL TO SEPTIC TANK DRAIN FIELD WATER MAIN TO SEPTIC TANK DRAIN FIELD SEPTIC TANK, �_� SEEPAGE PIT TO RIVER. LAKE, STREAM. SEEPAGE PIT ALSO CONSIDER AREA WELLS. SEEPAGE PIT DRAIN FIELD , CAST IRON INTO AND OUT OF SEPTIC TANK AND INTO CRIB CROSSING DAP OF EXCAVATION S FEET INTO UNDISTURBED SOIL. 4 INCH DIAMETER CAST IRON SIPHON PIPES ON SEPTIC TANK AND SEEPAGE PIT FITTED WITH AIRTIGHT REMOVABLE CAPS. GRAVEL BACKFILL CONFORM TO BOROUGH REGULATIONS REGARDING INSTALLATION. S, NEALT 1 AUTHORITY OR C7 LICENSED DESIGNER I CERTIFY THAT I AM FAMILIAR WITH THE REQUIREMENTS OF GREATER ANCHORAGE AREA BOROUGH ORDINANCE NO. 28.66 AND THAT THE ABOVE DESCRIBED SYSTEM IS IN ACCORDANCE WITH SAID CODE. �f 1 ,J DATE -�/-� APPLICANT'S SIGNATURE ` '� GR"TER ANCHORAGE AREA B(~JUGH sEPARTMENT OF ENVIRONMENTAL QUALITY PERMIT NO. - - $� 3300 TUDOR ROAD POUCH 6.650 ' ANCHORAGE. ALASKA 99302 1 TELEPHONE 279.8666 SEWAGE DISPOSAL SYSTEM — APPLICATION AND PERMIT s ' NAME OF APPLICANT - t--�,;,���-� t• Cf I L l 1C �f MAILING ADDRESS PNONgr� INSTALLATION LOCATION LEGAL DESCRIPTION INSTALLATION OF: SEPTIC TANK SEEPAGE PIT --� .DRAIN FIELD OTHER i TYPE AND SIZE OF FACILITY TO BE SERVED - - -LIA Y C 1 FINANCED THROUGH TO BE INSTALLED BY soa r6Br.REsuLTs < NOTEI THIS PERMIT IS NOT VALID WITHOUT SOIL TEST COMPLETION DATE ANTICIPATED FINAL INBPECTIONI 24 HOUR NOTICE REQUIRED. BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION BY THE HEALTH DEPARTMENT AUTHORITY WILL BE SUBJECT TO PROSECUTION. SEPTIC TANK 812E (�l ( (- TypE �(; ( Ii `'�(-(- SEEPAGE AREA SIZE 1-�2 TYPE MINIMUM DISTANCES, REQUIREMENTS DIAGRAM OF SYSTEM FOUNDATION TO SEPTIC TANK FOUNDATION TO SEEPAGE PIT DRAIN FIELD SEPTIC TANK TO SEEPAGE PIT WALL SEPTIC TANK SEEPAGE PIT DRAIN FIELD TO NEAREST LOT LINE. WELL TO SEPTIC TANK DRAIN FIELD - WATER MAIN TO SEPTIC TANK DRAIN FIELD SEEPAGE PIT ALSO CONSIDER AREA WELLS. SEEPAGE PIT SEPTIC TANK, SEEPAGE PIT DRAIN FIELD TO RIVER, LAKE, STREAM. CAST IRON INTO AND OUT OF SEPTIC TANK AND INTO CRIB CROSSING OAP OF EXCAVATION 6 FEET INTO UNDISTURBED BOIL. 4 INCH DIAMETER CAST IRON SIPHON PIPES ON SEPTIC TANK AND SEEPAGE PIT FITTED WITH AIRTIGHT REMOVABLE CAPS. GRAVEL OACKFILL CONFORM TO BOROUGH REGULATIONS REGARDING INSTALLATION. HEALTH AUTHORITY OR LICENSED DESIGNER I CERTIFY THAT I AM FAMILIAR WITH THE REOUIREMENTS OF GREATER ANCHORAGE AREA BOROUGH ORDINANCE NO. 26-65 AND THAT THE ABOVE DESCRIBED SYSTEM IS IN ACCORDANCE WITH SAID CODE. DATE - i - - ':F / i �C APPLICANT'S SIGNATURE MUNICIPALITY OF ANCHORAGE • Department of Health & Human Services y DIVISION OF ENVIRONMENTAL SERVICES 343-4744 CERTIFICATE OF INSPECTION FOR HEALTH AUTHORITY APPROVAL OF ON-SITE SEWER AND WATER FACILITY FOR SINGLE FAMILY DWELLING Parcel I.D. # n ra /!-?/ 14 HAA # �g- QU L 0 1. GENERAL INFORMATION (Must be completed prior to submittal) (a) Legal Description (include lot, block, subdivision, section, township, range) 91or-j: 5 IS=clle Rjver YewA/1 /Vor/15 S//) Location (address or directions) 08 y(9 f}nyi k 6 rc /e (b) Property owner CEI" 'e 8ain/24r v Telephone: (home) 69'Y-3x97Business 2Z/ -ST,rS Mailing Address i 06 qO A"- fr G 0-c to e Rraer 9'9,r'77_ V (c) Lending Institution A f4. Telephone Mailing Address (d) Real Estate Company and Agent 13"zf�y Pr lzer�,f-U C1ient- 9enle/i4e Address ��GO fkcr�zef/ iga� ,+ncji /� , 9-'�7 Telephone 3 t/ H- OS -G/ (e) Mail the HAA to the following address: (or check here Q if hold for pick up.) List contact person and day phone number below: Teo( 1 -to ore 3 yS- J35� 2. TYPE OF RESIDENCE Single -Family% Number of bedrooms 3 3. WATER SUPPLY Individual Well ❑ Community ❑ PublicfR Note: If community well system, must have written confirmation from the State Department of Environmental Conservation attesting to th legality and status. 4. SEWAGE DISPOSAL On-site ISI Public ❑ Community ❑ Holding Tank ❑ Note: If community well system, must have written confirmation from the State Department of Environmental Conservation attesting to the legailty and status. 72-025 (Rev. 7/88) Page 1 of 2 5. ENGINEERING FIRM PROVIDING INSPECTIONS, TESTS, FILE SEARCH, DATA AND INFORMATION As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health Authority Approval shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on the date of this inspection. Name of Firm Ffaffob 7ecAAicc✓ Servicer Telephone 3YS ' 1355— Address lYS30 Ecko 5,/ Anctiorage i4 % 11W 16 Date �F A4 AW d k �...................:... 0.......:... Engineer's Seal �� • CE b AV 6. DHHS APPROVAL Approved for 2 bedrooms by �' J, Date/ Approved K Disapproved Conditional Terms of Conditional Approval CAUTION The Municipality of Anchorage Department of Health and Human Services (DHHS) issues Health Authority Approval cerificated based only upon the representations given in paragraph 5 above by an independent professional engineer registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHHS do notconduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 72-025 (Rev. 7/88) Back Page 2 of 2 G� PrGt�G P G\ MUNICIPALITY OF ANCHORAGE (MOA) \�� o�y" • Health Authority Approval (HAA) CHECKLIST- FEBRUARY 1984 Legal Description: L.of 66� /ockc C C�t Ecr4le Rimer lfef!744Ar SIL)tVorA A. WELL DATAI� Well Classification Awwck If A, B, C, D.E.C. Approved (Y/N) Well Log Present (Y/N) Date Completed Yield Total Depth Cased to Depth of Grouting Static Water Level Pump Set At Casing Height Above Ground Sanitary Seal on Casing (Y/N) Electrical Wiring in Conduit (Y/N) Depression Around Wellhead (Y/N) SEPARATION DISTANCES FROM WELL: To Septic/Holding Tank on Lot ; On Adjoining Lots To Nearest Edge of Absorption Field on Lot ; On Adjoining Lots To Nearest Public Sewer Line To Nearest Public Sewer Cleanout/Manhole To Nearest Sewer Service Line on Lot Water Sample Collected by ; Date Water Sample Test Results Comments wake- Servwe- Rrovedeo( 4, /¢G!/ tyu —yer'ifr, we 10171ae B. SEPTIC/HOLDING TANK DATA Date Installed to/iyl016 Size 1009ratt No. of Compartments 2 Standpipes (Y/N) Y Air -tight Caps (Y/N) Y Foundation Cleanout (Y/N) N Depression over Tank (Y/N) N Date Last Pumped m,A- C Nau roArA Pumping/Maintenance Contact on File (Y/N) N.A. ; for Nr R. Holding Tank High -Water Alarm (Y/N) N.R. Temporary Holding Tank Permit (Y/N) A A, SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK: To Water -Supply Well :>w eoO' To Building Foundation 6 o4%aAk To Property Line ^ fof To Disposal Field __ 26� To Water Main/Service Line To Stream, Pond, Lake or Major Drainage Course Comments 5?;e c- DryefiHX ctWecx and buiiio,( 6" below crrounot, Itve( oeeGrin!Z rewayIncy otr drweauay i� s/�r�ny 72-026 (Rev. 7/86) Front Page 1 of 2 C. ABSORPTION FIELD DATA - Soils Ratingin Absorption Strata 1OU C7'48 f;..� �;oq V ' p Type of System Design setbawo P•P Date Installed (:911(1' 72 Length of Field f� Width of Field ! 2 Depth of Field Gravel Bed Thickness 6 Square Feet of Absortion Area pef Ar- i IL Statndpipes Present (Y/N) Y (_JCJWA1 w. got Ceri.e) Depression over Field (Y/N) 14 Date of Last Adequacy Test fa/19/&5' Results of Last Adequacy Test' Raf�uaf� ivr 3 �i�drtaov+f SEPARATION DISTANCE FROM ABSORPTION FIELD: To Water -Supply Well > 200 ' To Property Line to To Building Foundation 26" . To Existing or Abandoned System on Lot N.A. ; On Adjoining Lots 5-d To Water Main/Service Line 33. Jia`" C.o, )6 ='-To Cutback (if present) 1V, 14, To Stream, Pond, Lake, or Major Drainage Course > too To Driveway, Parking Area, or Vehicle Storage Area ander c&4 -e uwo s Comments Sccrye gWacT a- (Oo opal 4LAr. u,btor00%ron rVA c6S�9a�/cfov D. LIFT STATION fV A. Date Installed Size in Gallons "Pump On" Level at High Water Alarm Level at Tested for Meets MOA Electrical Codes (Y/N) Comments Dimensions Manhole/Access (Y/N) "Check Permitted Bedroom Rating Against HAA Request" "Pump Off" Level at Vent (Y/N) Pumping Cycles during Adequacy Test. I certify that I have checked, verified, or conformed to all MOA and HAA guidelines in effect on the date of this inspection. •�,OF AL��+ r Signed r `„�,. •.;�'�� Company /=laf9(a�v T�iinicrc/ Sgi�cey 0Cs�� �••,}09 0 * 49TH ` +EIA�ineer's Seal 4 20, f988 r ... .. Date ""' yy�� MOANo. 8g-2 t.••:...s•....... Y........ ,® �.: HEOCE-E..S6,9 OftE: AV Receipt No. 6� 02 7 a V tOo� `/ Receipt No. Date of Payment l U a O Amount: $ Waiver Fee: $:_ Date of Payment 72-026 (Rev. 7/88) Back Page 2 of 2 MUNICIPALITY OF ANCHORAGE -�, DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTIW'C'rl_i \\� �I� f '. - (//// 825 L Street - Anchorage. Alaska 99501 Fi �1 ENVIRONMENTAL ENGINEERING DIVISION Telephone 264-4720 NUMBER OF BEDROOMS J REQUEST FOR APPROVAL OF INDIVIDUAL WATER AND SEWERECCHVLV dc D DIRECTIONS: Complete all parts on page 1. Incomplete requests will not be processed. Please allow ten 001 days for processing. 1. PROPERTY OWNER z e e �e � e � S a'02 Three Cl Six PHONE 1c 95�- 9s o3� MAI LING ADDRESS ❑ INDIVIDUAL* to 7 A iVellX- C /.r C le. 4� le, /ti t' e-2 /�V,, PROPERTY RESIDENT (If different from above) —' N NE depth (attach log if available.) 8. SEWAGE DISPOSAL SYSTEM 2. BUYER PHONE LX INDIVIDUAL/ON-SITE` MAILING ADDRESS �- ❑ PUBLIC UTILITY 3. LENDING INSTITUTION NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED. PHONE /� � c✓ � d Pn . C�dr/u ¢.e S.�dio,d MAILING ADDRESS ' D / • • ,630 R.9 4. REALTOR/AGENT yi :.yf�e /c/ P ONE �y�- MAILING AD RESS i0 • ¢ o? E / �P 1�1s7 S. LEGAL DESCRIPTION /0 L' 4; _ X&AI a c A4 u if A, /7 L-5—L��r22 STREET LOCATION 6. TYPE OF RESIDENCE NUMBER OF BEDROOMS J IN SINGLE FAMILY ❑ One ❑ Four ❑ Other ❑ Two ❑ Five ❑ MULTIPLE FAMILY Three Cl Six 7. WATER SUPPLY ❑ INDIVIDUAL* ' ATTACH WELL LOG. A well log is required for all wells drilled l��i 1 COMMUNITY 0"e' /Y65 since June 1975. For wells drilled prior to that date, give well ❑ PUBLIC UTILITY depth (attach log if available.) 8. SEWAGE DISPOSAL SYSTEM �yc **If individual/on-site, give installation date/ /�2�Cc�(. /B LX INDIVIDUAL/ON-SITE` If system is over two (2) years old an adequacy test is required ❑ PUBLIC UTILITY by this Department. NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED. c. /� � c✓ � d Pn . C�dr/u ¢.e S.�dio,d 72-010(3/78) / CrJ. L`h .�is2viriy . 79 THIS SIDE FOR OFFICIAL USE ONLY -~ INSPECTION APPOINTMENTS DATE RECEIVED TIME TIME TIME DATE DATE DATE INSPECTOR INSPECTOR INSPECTOR DIRECTIONS: 1. TYPE OF RESIDENCE ❑ SINGLE FAMILY ❑ MULTIPLE FAMILY NUMBER OF BEDROOMS ❑ ONE ❑ THREE ❑ FIVE Cl OTHER ❑ TWO ❑ FOUR ❑ SIX 2. WATER SUPPLY ❑ INDIVIDUAL ❑ COMMUNITY ❑ PUBLIC UTILITY Connection Verified PERMIT NUMBER DEPTH OF WELL DATE DRILLED LOG RECEIVED 3. SEWAGE DISPOSAL SYSTEM ❑INDIVIDUAL/ON -SITE ❑PUBLIC UTILITY Connection Verified -- PERMIT NUMBER DATE INSTALLED INSTALLER ❑Septic Tank or ❑Holding Tank Size: If Tank is homemade give dimensions: SOILS RATING TYPE OF TANK MANUFACTURER TOTAL ABSORPTION AREA MATERIAL Y- 4. DISTANCES WELL T0: Septic/Holding Tank Absorption Area Sewer Line Nearest Lot Line Absorption Area to nearest Lot Line 5. COMMENTS ±_--APPROVED FOR BEDROOMS j ❑ CONDITIONAL APPROVAL (letter must accompany certificate( s, ❑ DISAPPROVED ; DATE BY IT 1- 4-, LEGAL DESCRIPTION u Ulu Rtev. Jute) eom M dna AUr 111/ILP Our. _I J_ 7 14. 5. LEGAL DESCRIPTION MUNICIPALIT OF ANCHORAGE Eagle River Hts No. Blk MUNICIPALITY OF ANCHORAGE DEPT. G "-"•!T� & STREET LOCATION DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTI&II,IRONi,/.ENTAL Pi;OTCCTION 825 L Street - Anchorage, Alaska 99501 • JUL 12 1979 6. TYPE OF RESIDENCE ENVIRONMENTAL ENGINEERING DIVISION Telephone 264-4720 i4� D REQUEST FOR APPROVAL OF INDIVIDUAL WATER AND SEW DIRECTIONS: Complete all parts on page 1. Incomplete requests will not be processed. Please allow ten (10) days for processing. 1. PROPERTY OWNER PHONE Gar Deardorff * ATTACH WELL LOG. A well log is required for all wells drilled MAILING ADDRESS since June 1975. For wells drilled prior to that date, give well Out of State PHONE PROPERTY RESIDENT (If different from above) Vacant PHONE 2. BUYER 243-1880 Lee Peterson INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED. MAILING ADDRESS Drive, Anchorage, AK PHONE 3. LENDING INSTITUTION L MAILING ADDRESS A �' rn K}'G-'`/ �L�LC-'� �� �- LIC' �-L Park Blvd, Ancage, AK h r ARusinp-,s OR/AGENT 4. REALTO Y (j . U �( Sc— � /p PHONE for Virginia Kohfield �r G151694-9555 --Myrna sTohnston MAILING ADDRESS 5. LEGAL DESCRIPTION Eagle River Hts No. Blk 5, Lot 6 STREET LOCATION NHN Anvik Circle 6. TYPE OF RESIDENCE NUMBER OF BEDROOMS ❑ One ❑ Four ❑ Other kk SINGLE FAMILY ❑ Two ❑ Five ❑ MULTIPLE FAMILY XC Three ❑ Six 7. WATER SUPPLY ❑ INDIVIDUAL* * ATTACH WELL LOG. A well log is required for all wells drilled COMMUNITY since June 1975. For wells drilled prior to that date, give well ❑ PUBLIC UTILITY depth (attach log if available.) B. SEWAGE DISPOSAL SYSTEM **If individual/on-site, give installation date 1 q7 3 INDIVIDUAL/ON-SITE** If system is over two (2) years old an adequacy test is required ❑ PUBLIC UTILITY by this Department. INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED. NOTE: THE 72-010(3/78) 1 14 j4r��, THIS SIDE FOR OFFICIAL USE ONLY INSPECTION APPOINTMENTS DATE RECEIVED TIME TIME TIME DATE DATE DATE INSPECTOR INSPECTOR INSPECTOR DIRECTIONS: 1. TYPE OF RESIDENCE ❑ SINGLE FAMILY ❑ MULTIPLE FAMILY NUMBER OF BEDROOMS ❑ ONE ❑ THREE ❑ FIVE ❑ OTHER ❑ TWO ❑ FOUR ❑ SIX 2. WATER SUPPLY ❑ INDIVIDUAL ❑ COMMUNITY ❑ PUBLIC UTILITY Connection Verified_LOG PERMIT NUMBER DEPTH OF WELL DATE DRILLED RECEIVED 3. SEWAGE DISPOSAL SYSTEM ❑INDIVIDUAL/ON -SITE ❑PUBLIC UTILITY Connection Verified PERMIT NUMBER DATE INSTALLED INSTALLER ❑Septi/c�Tank �o71 ❑Holding Tank Size: %k.�u�6 If Tank is homemade give dimensions: SOILS RATING TYPE OF TANK MANUFACTURER TOTAL ABSORPTION AREA MATERIAL G a 4. DISTANCES WELL TO: Septic/Holding Tank Absorption Area Sewer Line Nearest Lot Line Absorption Area to nearest Lot Line 5. COMMENTS V:1- APPROVED FOR 3 BEDROOMS ❑ CONDITIONAL APPROVAL (letter must accompany certificate) ❑ DISAPPROVED DATE BY (Title / LEGAL DESCRIPTION 72-010 (Rev. 3/78) 016M CONSULTANTS. INC. *Ola COH"GWA a 00- .nu 6 AHC.w H.1t. ALASKA 9Tf62 O •H. 907 ]If 1148) O Tu. ofO fa140 aeta.n.aawa 660600017• r1ANNa00 au..Vav00a July 26, 1979 R&M No. 951247 Virginia Kohfield Area Realty P.O. Box 249 Eagle River, Alaska 99577 Attention: Virginia Kohfield Re: Adequacy Test on Existing Sanitary Sewer System; Lot 6, Block 5, Eagle River Heights North Subdivision, Eagle River, Alaska. For Services Rendered Through July 26, 1979. Dear Ms. Kohfield: The following is our invoice for professional services rendered on the above referenced project. Invoice No. 951247-1 Professional Services Project Manager 1 hr @ $38.78/hr $ 38.78 Staff Geologist 8.5 hrs @ $25.20/hr 214.20 Word Processor 30 min. @ .50/min. 15.00 Total Invoice No. 1 $267.98 Please note our invoice number on your remittance. Should you have any questions concerning this invoice, please contact me or the Project Manager, Mr. Gary Smith. Thank you, R&M CONSULTANTS -k INC. C. J. Parisena Anchorage Office Manager CJP/rm/I5-D ANCHOR^" .AiNO ANna i RSM CONSULTANTS, INC. 5024 CORDOVA • BOX 6087 • ANCHORAGE, ALASKA 99502 ■ PH. 907-270-0483 ■ TLX. 0 90-2536 0 ENGINEERS GEOLOGISTS PLANNERS SURVEYORS July 26, 1979 Virginia Kohfield Area Realty P.O. Box 249 Eagle River, Alaska 99577 Attention: Virginia Kohfield R&M No. 951247 Re: Adequacy Test on Existing Sanitary Sewer System; Lot 6, Block 5, Eagle River Heights North Subdivision, Eagle River, Alaska. Dear Ms. Kohfield: Per your request of July 23, 1979, we conducted a test of the sanitary sewer system on the above described property. The septic tank was pumped prior to the performance of the test on the seepage pit. During the test the liquid level in the seepage pit was measured before and after the addition of 1,200 gallons of water. All liquid levels were measured below the top of the standpipe and are shown in the following table: Initial Water Second 24 hour Total Reading Added Reading Reading Drop (gallons) 118" 1,200 45.5" 89" 43.5" The water level rose 72.5 inches with the addition of 1,200 gallons of water, indicating a capacity of 16.5 gallons per inch. Twenty-four hours later the liquid level was again measured and found to be 7.4 feet. It had dropped 3.6 feet or 43.5 inches. This indicates an average effluent acceptance rate of 717.8 gallons per day for the surrounding soils. If the three bedroom residence on the property is to house six people, the average load on the system can be expected to be 450 gallons per day. We can therefore conclude that the system is disposing of effluent at an adequate rate for a three bedroom residence. ANCHORAGE FAIRBANKS JUNEAU VALDEZ WASILLA July 26, 1979 Virginia Kohfield Page -2- We appreciate this opportunity to be of service to you. Please contact us if you have any questions regarding this letter or if we can be of additional service to you. Very truly yours, R&M CONSULTANTS, INC. Ernest R. Rahaim Staff Geologist ERR:GS/rm/AT&SI-H Gary A. Smith Sen r r Geologist c 7- tl - _