HomeMy WebLinkAboutEARL RAY BLK 2 LT 7E lit/ GREA,IER ANCHORAGE AREA BOR JGH Department of Environmental Quality 3330 C Street Anchorage, Alaska 99503 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM SEPTIC TANK: DISTANCE FROM WELl INSIDE LENGTH MANUFACTURER INSIDE WIDTH ~.~~r MATERIAL . LIQUID DEPTH NUMBER OF COMPARTMENTS LIQUID CAPACITY //~)~ GALLONS. S'E-E-P A ~ E PIT: NUMBER OF PITS -- LINING MATERIAL BUILDING FOUNDATION ADDITIONAL ABSORPTION DIAMETER OR WIDTH__, LENGTH , DEPTH "~ """'"'x' CRIB SIZE: DIAMETER DEPTH D STANCE FROM: wE]'~,~., TOTAL EFFECTIVE . , NEAREST LOT LINE . ABSORPTION AREA (WALL ~R'EA) WELL: TYPE CONSTRUCTION BUILDING NEAREST NEAREST FOUNDATION- LOT LINE SEWER LINE CESSPOOL OTHER SOURCES APPROVED DISAPPROVED REMARKS DEPTH DISTANCE FROM: SEPTIC SEEPAGE TANK __ SYSTEM DISTANCES: DIAGRAM OF SYSTEM INSTALLED BY: PIPE MATERIAL: LOT SLOPE: REMARKS: DATE GREATEr ANCHORAGe Area BorOUGh DEPARTMENT OF ENVIRONMENTAL QUALITY 3330 "C" STREET ANCHORAGE, ALASKA 99503 TELEPHONE 27,4-4561 SEW~ DISPOSAL SYSTEM INSTALLATION LOCATION LEGAL DESCRIPTION '.STALLAT,ON OP: SEPTiCTANK TYPE AND SIZE OF FACILITY TO BE SERVED SOIL TEST RESULTS COMPLETION DATE ANTICIPATED , I~RAIN ~ j ~, OTHER NOTE.' THIS PERMIT IS NOT VALID WITHOUT SOIL TEST FINAL INSPECTION: 24 HOUR NOTICE REQUIRED. BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPEC IOI~NONJN BY THE DEPARTMENT OF ENVIRONMENTAL QUALITY AUTHORITY WILL BE SUBJECT TO PROSECUTION. ~ TYPE AREA SIZE . ' TYPE (/ MINIMUM DISTANCES, REQUIREMENTB FOUNDATION TO SEPTIC TANK FOUNDATION TO SEEPAGE PIT ., DRAIN FIELD SEPTIC TANK TO SEEPAGe PIT WALL SEPTIC TANK TO NEAREST LOT LINE. WELL TO SePtIC TANK SEEPAGE PIT / 7a- ~-8~b/ DRAIN FIELD ., DRAIN FIELD. ALSO CONSIDER AREA WELLS. WATER MAIN TO SePTiC TANK DRAIN FIELD . SEPTIC TANK, ., SEEPAGE PIT TO RIVER, LAKE, STREAM. SEEPAGE PIT / · ORA,~ E,ELD /~ CAST It~,ON INTO AND OUT OF SEPTIC TANK AND INTO CRIB CROSSING GAP OF EXCAVATION 5 FEET INTO UNDISTURBED BOIL. 4 INCH DIAMETER CAST IRON SIPHON PIPES ON SEPTIC TANK AND SEEPAGE PIT FITTED WITH AIRTIGHT REMOVABLE CAPS. GRAVEL BAGKFILL CONFORM TO BOROUGH REGULATIONS REGARDING INSTALLATION, OR · LICENSED DESIGNER 77 J CERTIFY THAT[ AM FAMILIAR WITH THE REQUIREMENTS OF GREATER ANCHORAGE AREA BOROL DESCRIBED SYSTEM IS IN ACCORDANCE WITH SAID CODE, DIAGRAM OF SYSTEM ~D[NANCE NO. 28.~6~N D Ct E GEO<--]'CHNICAL 6' DEVEL .~"?MENT CO. ,usse# Oyster 694-2774 Soils ~ Foundations Performed for: Legal DesCriPtion: Box 90, Davis St,, Eagle River, Alaska 99577 694-2774 or 688-2280 SOIL LOG Name: ~',~"' x'-~, Mailing Address: Earl Ellis 688-2280 d (~ff~ Land Development Tel. No. Depth (feet) Soll Characteristlc~ 7 , 8 ' 3_O 12 ~5, ].6 Ground Water Encountered: Yes 'z/ Proposed Installation: Seepage Pit Comments: ~ ~,b,t--~-~'u- ~, ~4> Performed by: ~~ ~ ~ No__ If yes, what depth Drain Field ~'~ Date: GREATER .ANCHORAGE AREA BOROUGH Departmeht bf Environmental Qual ity 3330 "C" Street, Anchorage, Alaska 99503 274-4561 /4~' - / _ ) Date Received July 15, O~'/~DUAL SEWER & WATER FACILITIES i. Approval requested by: . Mailing Address: Phone: 1976 .2;-~operty Owner: Paul R. Smith Phone: ~l Description: Lot 7 Block 2 ~a~!':'Ray Subdivision 22 miles Glen Highway. 'of facility to be inspected Individual A.' Type B. Depth~ No. of bedrooms . C. Construction . ~ 7~ 'Sewage DiSposal System: ~i;- ' '- ~ A. Installed ~i~ , ~ C. Septi:c Tank: 1. D. Bacterial Analysis ! On- s~te'~' .syst~ , B~ '40sta~l er i /~ ;\ "2.. Manufacturer Siz~ D. Seepage Pit:~ 1.~ Absgrption Area E. Disposal Field: Total~length of lines Distances: · / - A. Well to: Septic tank' ?~ , Absorption area Nearest lot line c~/ ~ , O~her contamination 2. Material se~r 'lines B. Foundation to septic tank , AbSorption area C. Absorption area to nearest lot line Pag6'l o.f two SATURDAY S M T W T F $ -~.~ 12 13 14 15 16 17 18 ~ 19 20 21 22 23 24 25 ~ w- 26 27 28 29 30 25 SEPT. 1976 DEPT. OF HE~,LTJ-J~ MUNICIPALITY OF ANCHORAGE ENVIRONMENTAL'~O~{~,,--[ DEPARTMENT OF HEALTH AND ENV RONMENTAL PROTECTION 2510 East TUdor Road. Anchorage, Alaska 99504 276;222i REQUEST FOR APPROVA' OF INDIVIDUAL SEWER and WATER FAClLITIES . 1. Type of Inspection: ....3CMRO ~ _ VA FHA CONV , 2. P~operty Owner: Mailing Address: - , ~ Day Phone: - . _ 3. Name of Buyer: Mailing Address: Day Phone: 4. Name of Lending Institution: Mailing Address: Phone: 5. Name of Realtor or Agent: .... Mailing Address: ~ ,, Phon 7. Type of Facility to be nspec~d~~: 8. Water. Supply Type of Supply: No. Bdrms. Public Utility ,Individual 72-003(3/76) If Individual, number of dwellings pries.emily; If Individual, depth of well Sewage D!sposal System Type of System: If ndividual, date of installation Public Utility Individual (on-site) ige-"2.o~'two-'~,, ,,pga es, - Re. _ ~t for~ Approval .of Individual _ .r & Water ~cri'pt~i.o[~ LOt 7 Block-,2 Earl Ray Subdl-vmsmon . C'om~entS Approved Disapproved Date. Approval ~Valid for one year from date signed ? Greater Anchorage Ar~a Borough, Deoartmen~ of Environmental ,quality - DIAGRAM OF SYSTEM I c'ertify that ~he information containedin this request for-approval, to be i accurate representationof the subject sewer andwater faci ~re~oPerating sa~isfac~orily~ D~te EXCAVATION WORK. September 1, 1982 MUNICIPALITY OF ANCHORAGE DEPT 0~ HE,^LTH ~ ENVIR ),'~t,!Z/jA-. F'f¢O E TIZ ,',1 Mrs. Mary Smith SR Box 1420 Old Glen Highway Chugiak, Alaska 99567 RECEIVED Dear ~,'Irs. Smith, ROBERT A. SHAFER CIVIL ENGINEER 694-2979 Reference: Lot 7: Block 2: Earl Ray Subdivision A sewer system adequacy test was performed on the system located on the referenced property as you requested. The septic tanks for the main dwelling and the two bedroom 5railer house located on this propersy were all pumped. The two septic tanks for the main dwelling were verified to have a capacity of approximately 1000 gallons each. The septic tank for the trailer was verified to have a capacity of approximately 750 gallons. The absorption trench connecting these three septic tanks provides effluent disposal for five bedrooms in the main dwelling, two bedrooms in the trailer, a small snack stall automotive garage having one rest room. There is also located in the main dwelling a room w~th video machines and two rest rooms, one male and one female with one water closet and one lavatory in each. The absorption trench was tested by a continuous flow of water over a period of 48 hours. The flow rate was adjusted to merely represent the composite of all the requirements generated from the existing facilities~ At the conclusion of the 48 hour period the flow for each 24 hour period was determined uo have no adverse effect on the system. It-can be concluded from this test that the waste wat~r~d~isposat system serving the composite of facilities loCated on this property is currently funCtioning adequately. HoweVer, the system cannot be guaranteed against further failure. If we may be of further assistance please do not hesitate to call. Sin ~c~ly, / .E. cc:- Municipality of.Anchorage Department of Health and Environmental Protection SRE 196X EAGLE RIVER, ALASKA