Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
EKLUTNA HGTS STEWART ADDN LT 9
Eklutna Heights tcwart Add. Lot 9 · ! - 063 -26 Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program, 4700 Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 Page 1 of 4 www.ci.anchorage.ak.us (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number: SW101218 PID Number: 051-063-26 Name: Lana Grist WastewaterSystem: [] New [] Upgrade Address: 21642 Bear View Place ABSORPTION FIELD Phone: Number of Bedrooms: [] Deep Trench [] Shallow Trench [] Bed [] Mound [] Other: LEGAL DESCRIPTION Sol, Rating: Total Depth from original grade: 0.6 GPD~Ft2 12.1 Ft. Block: Lot: Subdivision: Depth to pipe bottom from original grade: Gravel depth beneath pipe: 9 Eklutna Heights Stewart Addition 5.6Ft. 6.5Ft. Township: Range: Section: Fill added above original grade: Gravel Length; 0 Pt. 58 Ft. Well: [] New [] Upgrade Gravelwidth: Numberoflines:I Distance between lines: 5 Ft. 1 Ft. Classification (Private, A, B, C): Total Depth: Cased to: Total absorption area: Pipe Material: I Existing Private pt. Ft. 754 Ft2 3034 PVC Driller: Date Drilled: Static Water Level: Installer: Date Installed: Ft. Flinstone Excavating 10/2812010 Yield: I Pump Set at: I Casing Height Above Ground: CPMI Ft.I Ft. TANK SEPARATION DISTANCES [] Septic [] Holding [] S.T.E.P. [] Other: T~_To Septic Absorption Lift Holding >ublic/Private Manufacturer: Capacity: From~ Tank Field Station Tank Sewer Line Anchorage Tank 1000 Ge~. Material: Number of Compartments: Wel, 84.0 105.8 ~'~ Steel 2 Surface Water 100+ 100+ ~ / LIFT STATION Lot Line 22.8 0.8~ Size: Manufacturer: Gal. Foundation 24 43.3 "Pump on" level at: "Pump off" level at: in. High water alarm at: Curtain Drain N/A N/A Pump Make & Model Electrical Inspections performed by: Remarks: Existing tank abandoned per code. BENCH MARK Location and Description: Drain field to lot line waiver #050001, Deck Foundation See attached letter for Septic Tank to Well waiver. Assumed Elevation: 100.0 Ft. Engineer's Stamp Inspections performed by: PANNONE ENG. SVC, LLC Dates: 1st 10/27/2010 Development Services Department Approval Conditional Approval Date: ,~- ~ .................................. .,....~ ~'~tSLeven iR. ?annone~',~. Reviewed and approved by: /-~'/" te: ~" ,_~ / / / I NOTE: Contractor had well radii staked before construction as well as adjacent property lines. DRAIN FIELD (E) TO WELL -- PRIMARY DRAIN FIELD REPLACED AND IN SAME LOCATION/PROXIMITY AS EXISTING SYSTEM 58LF x 5'W x 6.5'ED x IO'TD DRAIN FIELD (E) DRAIN FIELD (E) EXISTING SEPTIC TANK ABANDONED PER CODE EXISTING DRAINFIELD ABANDONED PER CODE BY REMOVAL. REMOVED BIOMA~q'ED GRAVEL BACKFILLED W/ CLEAN PIT RUN GRAVEL. lO00g SEPTIC TANK !04-1 FC TH-2 -- 84.0 D/W 105.8 EXISTING t4/~ W-- 3BR HOUSE D 95.2 104.7 WELL (E) WELL- 1 (E) rY LO WELL-2 ~- (E) NOTES: RECORD DRAWING PLAN PANNONE ENG SVC, LLC P.O. BOX 100217 ANCHORAGE, AK 99510 PHONE (907) 272-8218 FAX (907) 272-8211 EKLUTNA HEIGHTS STEWART ADDN LANA GRIST 21642 BEAR VIEW PLACE CHUGIAK, AK 99567 LOT 9 Date 11/4/10 Scale 1 "=30' P.I.D. NO 051-063-26 PERMIT NO. 0SP101218 Sheet 20F4 SPECIAL PROVISIONS TO SPECIFICATIONS 1. ALL CONSTRUCTION SHALL BE INSTALLED AS SPECIFIED IN THE MOST CURRENT EDITION OF THE MUNICIPALITY OF ANCHORAGE STANDARD SPECIFICATIONS (MASS) FOR COMPONENT PARTS AND MATERIALS USED IN CONSTRUCTION OF ON-SITE WASTEWATER DISPOSAL SYSTEMS. 2. ALL WORK SHALL BE IN ACCORDANCE WITH THE AXFACHED SPECIFICATIONS. 3. SCOPE OF WORK: INSTALL NEW 1000 GALLON SEPTIC TANK AND NEW SOIL ABSORPTION SYSTEM. 4. NO GROUNDWATER WAS OBSERVED AS EVIDENCED BY THE SOIL TEST HOLE. IF AN APPARENT WATER TABLE IS OBSERVED IN ANY OF THE EXCAVATIONS LESS THAN 16.0 FEET BELOW EXISTING GRADE, NOTIFY THE ENGINEER IMMEDIATELY. TH 04-1 98.5 -0.5 --~ 98.3 GM . GM - ~~86.2 6.2 m CD -18.3 BO-~ 80.2 ~ n z NO GROUNDWATER o z o z O~ ~ ~ ~ Z~ Z~ ~ ~ ~ MONITORED ~ -- <0 0 0 ~ ~ o~ ~ ~ < ~ 6" TOPSOIL AND VEGETATION < < < % Z~ / Z~ OJ ~ ~ 0~ ~ 9 ~ / ~ FILTER FABRIC o 98.5 i , ~ ~93.5 3.4 SEPTIC ................ ' ..... ~ ........ , .................................... 92 7 TANK TRENCH 58 LONG, 6.5' DEEP, 12.1' T.D. DRAIN ROCK BELOW PIPE PROFILE DESIGN PARAMETERS ABBREVIATIONS LEGEND PRIMARY/RESERVE SEPTIC SYSTEM NO. BEDROOM: 3 (450 gpd) CU COPPER ~ W WATER LINE/ TANK SIZE: 10009 DIP DUCTILE IRON PIPE WELL RADIUS PERC RATE = 16 MPI TH TEST HOLE SOIL RATING: 0.6 GPD/SF FC FOUNDATION CLEAN OUT ~ SS NEW SEPTIC AREA RQD: 750 SF T~ TANK CLEAN OUT NO. SYS. ~PE: WIDE TRENCH 6.5' E.D. C~ CLEAN OUT NO. MIN LENGTH: 57.7 LF M~ MONITOR TUBE NO. USE: R.I. RIGID INSU~TION DCO DOUBLE CLEAN OUT 58 LF X 5' WIDE, 6.5' E.D., 12.1' TD DV DIVERTER VALVE TOTAL AREA: 754 SF FS FLOW SPLICER OO lZ Scgle EKLUTNA HEIGHTS STEWART ADDN LOT 9 - anno~e ~ 0~1-063-26 21642 BEAR VIEW PLACE ~~~~ ~ ~ ,. .,,~ 0SP101218 DESIGN DETAILS CHUGIAK, AK 99567 Sheet 50F4 SOILS LOG - PERCOLATION TEST TEST HOLE SLOPE ~ SITE PLAt ~-~ 3 HOLE ~"~/~ ~_~ 5-- 7-- 6 O -1 EXISTING ~0 ~ 'HOUS~ BOH & x ENCOUNTERED? N IF YES, AT WHAT TH 1 DEPTH? -0-' X DEPTH TO WATER AFTER MONITORING? DATE: I CLOCK WATER READtNG DATE TIME NET TIME LEVEL NET DROP READING 1 10-28-10 11:41 2.97 2 11:51 10 MIN 6.30 3.33 3 11:52 2.97 4 12:02 10 MIN 6.46 3.49 5 12:03 2.97 6 12:13 10 MIN 6.29 ~ 3.32 PERO~TION ~TE 3 (min/inch) PERC HOLE DIAMETER 6 inches TEST RUN BE~EEN 4 FT AND 5 FT COMM~N~S: Test hole excavated by ~J~tsto~e ~te~Jse. Test ~o]e was pteso~ed before pete test. AddJtJo~ pemo]atio~ test pe~fo~ed at time of ~stMl9fio~. OT S: RECORD DRAWING P.0. BOX 100217 ANCHORAGE, AK 99510 ~.9~.~ ~, 11/4/lO ¢,0~[ (~07) 272-8218 F~X (~07) 272-8211 " ~.~.D. LANA GRISTfa~ra ~-.. CE 8149 ..._~,~ :ERMIT NO. 21642 BEAR VIEW PLACE ,~i~.. ..~ osmo~2~s SOILS LOG CHUGIAK, AK 99567 ~t~O~SS~9A~,,~ ....... ~'~ Sheet 4 4 READING DATE CLOCK WATER TIME NET TIME LEVEL NET DROP READING 1 10-28-10 11:41 2.97 2 11:51 10 MIN 6.30 3.33 3 11:52 2.97 4 12:02 10 MIN 6.46 3.49 5 12:03 2.97 6 12:13 10 MIN 6.29 3.32 Municipality of Anchorage P.O. Box 196650 · 4700 Elmore Road Anchoraqe, Alaska 99519-6650 · (907) 343-7904 · Fax (907) 343-7997 http:llwww.muni.or.qlOnsite Development Services Department On-Site Water and Wastewater Program epartment **** VARIANCE~VAIVER REVIEW **** Waiveng: OSP101264 COSA#: Permit/t: OSP101218 PID#: 051-063-26 Legal Description: Eklutna Hei.qhts Stewart Addition Lot 9 Engineer: PES Applicant: Lana Grist Your request for the waivers of the required 100 feet horizontal separation from the septic tank to the private wells have been approved. The approved separation distance is 84 feet to the well on the lot and 95 feet to the well on lot 10. This waiver approval applies to the existing septic tank only. Any future upgrade to the on-site wastewater disposal system will require all separation distances be met or another approval from this department. Waiver is Granted: X Waiver is not Granted: Name of Reviey/er Rec~: Amount: Date Paid: **** VARIANCE/WAIVER REVIEW **** Eklutna Heights, Stewart Addition Lot 9 Parcel ID: 051-063-26 Waiver for 84 feet to well and 95 feet from well on Lot 10 Issued November 9, 2010 General 1. Any overflowing sewage would have to travel around the house to get to the well head. 2. Nitrate levels are undetectable in lot 9 well and are at 4.09 mg/L for lot 10. 3. Well log for lot 10 is unreadable so data from lot 9 well log will be used. ADEC Criteria Water Table Depth of water bearing zone in well Assumed bottom of field 147 feet 12 feet 135 feet Soil Sorption Soil descriptions DEC PTS Depth From Depth To Thickness Calc. Pts Sand and Gravel 0.75 12 Clay and Gravel 5 123 Sand and Gravel 0.75 142 123 111 0.62 142 19 0.70 147 5 0.03 Points Permeability Soil descriptions 7.2 135 1.35 1.3 DEC PTS Depth From Depth To Thickness Calc. Pts 111 0.82 19 0.00 5 0.04 0 0.00 0 0.00 0 0.00 0 0.00 135 0.86 0.9 Sand and Gravel 1 12 Clay and Gravel 0 123 Sand and Gravel 1 142 Water Table Gradient - Water table has no slope Assume minimum +0% slope Horizontal Separation 84 feet between septic tank and well x -- 9/25 + 2.0 123 142 147 2.9 2.36 Total Points 14.7 As per ADEC waiver guidelines, with a minimum point value of 14.7, no bacterial polution possible but chemical pollution possible but unlikely from household chemicals. Pannone Engineering Services LLC Steven R. Pannone, Principal Registered Professional Engineer E-mail: steve@panenRak.com November 5, 2010 Municipality of Anchorage Development Services Department On-Site Water & Wastewater Program 4700 S. Bragaw Street Anchorage, Alaska 99519 Subject: Eklutna Heights S/D, Stwerat Addition, Lot 9 Waiver Request Ladies and Gentlemen: l am writing to request that a separation Waiver be granted for this property. The well is a private well serving a single family home. PES designed and obtained a permit (OSP101218) to install a new septic tank and drain field. The tank was designed to be located in the north east corner of the lot, outside the well radius. When the tank was being installed, we encountered effluent from the neighboring drain field pouring into the excavation. PES contacted your department and your inspector Mr. Jeff Poet came out the site to investigate. There was no other location outside the well radius to install this new tank. The new tank was installed at its current location after discussions with your department. The tank was placed five feet from the abandoned existing drain field. I request the tank to well waiver cost be waived due to the nature of this emergency placement. We, in good faith, intended to place the tank outside the well radius. We were unable to do so due to effluent impacting my client's property. Waiver Request. I request the following waiver: a. Well on Lot 9 to Septic Tank from 100 feet to 84 feet b. Well on Lot 10 to Septic Tank from 100 feet to 95 feet The existing drain field on this lot was in failure and was upgraded as part of OSP 101218. The old drain field's biomatted material was removed and disposed of off site. A new drain field was installed outside the 100 foot radius. The soils we encountered to 16 feet below the ground surface were silty sands and gravel having a percolation rate of 16 to 20 minutes per inch. The top of the distribution pipe is four feet below the ground surface. The ground at the drain field is located approximately two feet above the ground at the well casing. The ground slopes from the drain field towards the well and surface contamination is unlikely due to the house being direct line between the two. The well is Mailing; P.O~ Box S,002~.7, Anchorage~ Al< 99510...0217 Physicak 61i.5 [!.ast 82© Ave, Suite g..6, Anchorage~ AK 99508 Telephone: (907) 27T.82~8 FAX: (907) 272~82S.~ Page 2_ of 2 located on the eastern portion of the lot. The static water level in the well is 65 feet below the top of the casing (63 feet below ground level). The hydraulic gradient is five to ten percent to the south, away from the well. The soils are sandy gravels having an application rate of 250 sf per bedroom. In review of the ADEC Waiver Memorandum the following points are tabulated: Section Points Water Table (53 ft) 5.5 Soil Sorbtion (Silty Sand) 3.5 Permeability 1.5 Water Table Gradient (+12%) 6.0 Horiz. Separation (85ft) 2.5 Total 19.0 points 16-25 points: Almost sure to be free from any form of contamination from household sewage. The water results for the well located south of the tank on lot 10 indicated a 0.1 U in a water test performed in July of 1005. The surrounding lots are developed. The existing septic systems are located greater than 100 feet from this well and over ten feet from the property lines. Granting this waiver will not affect the operations or availability of the surrounding lots to develop or install an on-site sewer disposal system nor endanger the health and safety of the public. If you have any questions or concerns, please contact me at 272-8218. Sincerely, . · ............. ? ..~ Steven R. Pannone, P.E. Owner/Civil Engineer Attachments: Mail, · n,g~>' P,O, Box 100217, Anchorage~ Al( 9951.0..0217 Physicah 61.5 fi. asr $2® Ave, Suite B..5, Anchorage, AK 99508 Telephone: (907) 272,,.8228 FAX: (907) 272-821t. Permit Number: Tax Code Number: Work Type: On-Site Wastewater Disposal System Permit OSP101218 05106326000 Septic MUNICIPALITY OF ANCHORAGE Development Services Department On-Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Renewal Permit Effective Dates: October 14, 2010 to October 14, 2011 Design Engineer: PANNONE ENGINEERING SERVICE Subdivision: EKLUTNA HGTS STEWART ADDN Site Legal Address: EKLUTNA HGTS STEWART ADDN LT 9 Owner/Address: GRIST LANA J PO BOX 670391 CHUGIAK AK 995670391 G:1460 Site Mailing Address: 21642 BEAR VIEW PL, Chugiak Lot Size in Sq Ft: 8400 Total Bedrooms: ,,4'" .-~ This permit is for the construction of: Y Disposal Field Y SepticTank N Holding Tank N Privy N Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Special Provisions: The entire subsurface disposal field and/or alternate is not within a 30 foot radius of a percolation test. The Engineer needs to do an additional percolation test prior to the construction of the septic field. Please submit stamped and signed results with the As-built Inspection Report. If the results require a design change, construction of the system will stop pending On-Site review and approval. AMC 15.65.060.B.3 , , , ~¢~/~ (_.LO-*/ ~;~ ~":f'~ ''" '~'""~" ,,~b~, Date: Date: //~AL'~/,/~ Municipality of Anchorage P.O. Box 196650 ® 4700 Elmore Road Anchorage, Alaska 99519-6650 · (907) 343-7904 · Fax (907) 343-7997 http:llwww.muni.or,qlOnsite Development Services Department On-Site Water and Wastewater Program ~epartment **** VARIANCE/WAIVER REVIEW **** Waive~: 050001 COSA#: Permit~: OSP101218 PID#: 051-063-26 Legal Description: Eklutna Hei.qhts Stewart Addition, Lot 9 Engineer: PES Applicant: Lana Grist Your request for a waiver of the required 10 feet horizontal separation from the absorption field and septic tank to the property line has been approved. The approved separation distance is 0.0 feet. This is a modification of the 2005 waiver. This waiver approval applies to the proposed absorption field and tank only. Any future upgrade to the on-site wastewater disposal system will require all separation distances be met or another approval from this department. Waiver is Granted: X Waiver is not Granted: Date: /I~/~//D Approved by: Name of Reviewf¢' Rec#: __ Amount: Date Paid: **** VARIANCE/WAIVER REVIEW '**** Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700 Elmore Road P.O. Box 196650 Anchorage, Alaska 99507 www. muni.org/onsite (907) 343;7904 ON-SITE SEWER/VVELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Properly owner(s) .L,v~ Mailing address ;~_.J6~. ~',,~/~ Site address ~[~ ~ Legal description (Sub'd., Block & Lot) Legal description (Township, Range & Section) Lot Size ~ Sq. Ft. Day phone Zip Code Zip Code Number of Bedrooms THIS APPLICATION IS FOR ([~ all that apply): Absorption Field Septic Tank Holding Tank Privy Private Well Water Storage THIS APPLICATION IS AN: Initial [] U pg rad e [] Renewal ~ I certify that the above information is correct. I further certify that this application is being made for a Single Fa/r~ly2welling and is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) I Permit/Rush Fees: Date of Payment: Receipt Number: ~f (Rev. 11/05) Waiver Fees: Date of Payment: Receipt Number: Pannone Engineering Services LLC Steven R. Pannone, Principal Registered Professional Engineer E-mail: steve@panengak.com October 12, 2010 Municipality of Anchorage Development Services Department On-Site Water & Wastewater Program 4700 S. Bragaw Street P. O. Box 196650 Anchorage, Alaska 99519 Subject: Eklutna Heights Stewart Addition, Lot 9 Septic System Permit Upgrade Request Ladies and Gentlemen: I am writing to request a permit to construct an upgraded septic system be issued for this property. The proposed systems will serve an existing three-bedroom house. Currently the lot is developed. The lot is served by a private water supply. The existing septic system is in failure and will be removed in accordance with municipal standards. A new drain field will be installed in the same location as the existing field. The surrounding developed lots are served by private water systems. The private wells are located over 100 feet from the proposed soil absorption system. We will excavate a test hole and perform a percolation test at the south end of the new field during construction. 1. Soils. A single test hole was excavated by KND Engineering in December of 2004. See the attached soil log. Ground water was monitored for seven days. No ground water was monitored to a depth of 16 feet below ground level after the monitoring period. Bedrock was not encountered in the test hole. It is my opinion, based on the results of the percolation tests and overall soils appearance; an application rate of 0.6 gallons/day/square feet should be used, using a 1250 gallon S.T.E.P. tank that utilizes a pressure discharge into a wide trench. Soil Absorption System Design. See Design Drawings sheet 2 of 2 for design calculations. 3. Waiver Modification: We request the existing lot line waiver (WR050001) be modified from 5.0' to 0.0' between the drain field and septic tank to the property line, due to increasing the number of bedrooms the trench length increases 5 linear feet. Granting this modification will not affect the future development of the surrounding lots. 4. Reserve Field: The original system was designed for two bedrooms. The house currently has three bedrooms (see Muni printout). This lot does not have space for a reserve system outside the well radii. When this three bedroom system eventually fails, the upgrade location will be in the same location, I.E. the Mai!in(~: P.O. Box ~i902117,~ Anchorage~ AK Physicai: 615 Easl; 82nc~ Ave, Cuh:e BG~ Ancho~'age, A~( 99505 Telephone: (907) 2'72~8218 FAX: (907) 272.--821. t Page 2 of 2 system will need to be rebuilt in the same location. 5. Surface Water: There is no surface water within 100 feet of the proposed septic tank and the existing drain field. The proposed drain field upgrade will maintain at least 100 feet from all surface water and drainage ditches. 6. Topography: The average topography in the area of the proposed septic system is approximately flat based on the survey information. The proposed installation will be greater than 50 feet from the shoulder of the steep slopes. 7. Drawing Markings: The Drawings are marked "For MoA Review Only". When written notification that the review is complete and that there are no further comments is received from MoA On-Site Department, the note will be removed and "Issued for Construction" drawings will be issued. The proposed installation will not affect the future development of the surrounding or existing lots. There are no wells or septic systems within 100 feet of the proposed septic location. If you have any questions or concerns, please contact me at 272-8218. Sincerely, ........... ¢.%o ~'¢.-" 49TH '~ ~ ...... Steven R. P~one, P.E. OmeffCivil Engineer Attachments: MaiNn~: P,Ct. Box 100217, Anchorage, AK 99510,.-0217 Physicaf; 615 East 82~d Av% Cuite B6~ Ancho~'age, Ai( 9950~ Telephone: (907) 272~821.8 FAX: (907) 272-8211 NOTE: Contractor shall have well raa~ staked before construction as well as adjacent proper~ lines. NOTES: ISSUED FOR CONSTRUCTION DRAIN FIELD DRAIN FIELD 16 WELL (E) .~X' DRAIN FIELD 15 '~---- W--J~"~-WELL (E) 14 13 PLAN /--DRAIN FIELD (E) ._4// j -:-~ --WELL (E) ~/- PROPOSED 1 250g ~M -----___~ S.T:E.P. TANK i -.~...~ ~o4~-~x~s3~ ,. s~ ~ous~ -w~uu (q PRIMARY DRAIN FIELD (P) TO REPLACE AND BE IN SAME LOCATION/PROXiMITY AS 1 EX~ST~NG SYSTEM 58LF x 5'W x 6.5'ED x IO'TD / PANNONE ENG SVC, LLC °~,1~%~/~o P.O. BOX 100217 ANCHORAGE, AK 99510 PHONE (907) 272-8218 FAX (907) 272-8211 Sca~e 1"=50' P.I.D. NO EKLUTNA HEIGHTS STEWART ADDN LOT LANA GRIST PERMIT NO. 21642 BEAR VIEW PLACE OSplO121a CHUGIAK, AK 99567 Sheet 1OF2 SPECIAL PROVISIONS TO SPECIFICATIONS 1. ALL CONSTRUCTION SHALL BE INSTALLED AS SPECIFIED IN THE MOST CURRENT EDITION OF THE MUNICIPALITY OF ANCHORAGE STANDARD SPECIFICATIONS (MASS) FOR COMPONENT PARTS AND MATERIALS USED IN CONSTRUCTION OF ON-SITE WASTEWATER DISPOSAL SYSTEMS. 2. ALL WORK SHALL BE IN ACCORDANCE WITH THE ATTACHED SPECIFICATIONS. 5. SCOPE OF WORK: INSTALL NEW 1250 GALLON S.T.E.P. TANK AND NEW SOiL ABSORPTION SYSTEM. 4. NO GROUNDWATER WAS OBSERVED AS EVIDENCED BY THE SOIL TEST HOLE. IF AN APPARENT WATER TABLE IS OBSERVED IN ANY OF THE EXCAVATIONS LESS THAN 1 6.0 FEET BELOW EXISTING GRADE~ NOTIFY THE ENGINEER IMMEDIATELY. 04-1 BOH NO GROUNDWATER m ~ r'n Q3 MONITORED ~ ~ OZ Z~ ~ 6" TOPSOIL AND VEGETATION ~ < z~ z~ o ~ FILTER FABRIC o ~ // ~- DRAIN ROCK 6" ABOVE PIPE // NEW 1250 g :: i.?.'i-:'?!.)'}:'"('!??¢?!,¥:,':'?,:!!':;li";}i - ~/4" HOLES 1.5' Ts2T' TRENCH 58 LONG, 6.5' DEEP, 10' T.D. ~ PROFILE DRAIN ROCK BELOW PIPE I DESIGN PARAMETERS PRIMARY/RESERVE SEPTIC SYSTEM NO. BEDROOM: 5 (450 gpd) TANK SIZE: 1250g S.T.E.P. PERC RATE = 16 SOIL RATING: 0.6 GPD/SF AREA RQD: 750 SF SYS. TYPE: WIDE TRENCH 6.5' E.D. MIN LENGTH: 57.7 LF USE: 58 LF X 5' WIDE, 6.5' E.D., 10' TD TOTAL AREA: 754 SF ABBREVIATIONS CU COPPER DIP DUCTILE IRON PiPE TH TEST HOLE FC FOUNDATION CLEAN OUT T# TANK CLEAN OUT NO. Off CLEAN OUT NO. M# MONITOR TUBE NO. R.I. RIGID iNSULATiON DCO DOUBLE CLEAN OUT DV DIVERTER VALVE FS FLOW SPLITTER W LEGEND WATER LINE/ WELL RADIUS ~ SS ~ NEW SEPTIC NOTES: ISSUED FOR CONSTRUCTION DESIGN DETAILS PANNONE ENG SVC, LLC P~O. BOX 100217 ANCHORAGE, AK 99510 PHONE (907) 272-8218 FAX (907) 272-8211 EKLUTNA HEIGHTS STEWART ADDN LANA GRIST 21642 BEAR VIEW PLACE CHUGIAK, AK 99567 LOT JDate I 10/14/10 Scale NTS P.LD. NO PERMIT NO. 0SP101218 Sheet 20F2 MUNICIPALITY OF ANCHORA GE Development Services Department On-Site Water & Wastewater Program 4700 South B~agaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343.7904 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Initial I Upgrade Date Issued: Jan 10, 2005 Expiration Date: Jan 10, 2006 Permit Number: SW050007 Legal Description: ~I. UTNA HGTS STEWART ADDNi~T"9~ Design Engineer: 0070 KND Engineering Owner Name: LANA GRIST Owner Address: 21642 BEAR VIEW PLACE CHUGIAK, AK 99567- Parcel ID: 051-063-26 Site Address: 021642 BEAR VIEW PL Lot Size: 6400 SQ. FT. Total Bedrooms: 2 Permit Bedrooms: 2 This permit is for the construction of: [] Disposal Field [] Septic Tank [] Holding Tank [] Privy [] Private Well [] Water Storage construction must be in accordance with: 1. The attached approved design. 2. Ail requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of AJaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. ReceivedBy~ ~ ~~ Issued B~ Date: Date: Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage. AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 ON-SITE SEWERJWELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. 051-063-26 Permit Number SW Property owner(s) Lane Gri.nt Mailing address (1) P{3B 670391 Chugiak.. AK 99567 Malting address (2) ~tL~q~L ~ '~J'[,ccc~ {3~, Zip Code Legal description (Lot, Block & Sub'd.) I:klutna Ht~.: ~tewert Add... Lot Legal description (Section, Township & Range) Dayphone-~3~~ Lot Size (~ L{C~) Acr~ THIS APPLICATION IS FOR: Sewer Only Sewer and Well Sewer Upgrade THIS PROPERTY CONTAINS: Hot Tub Swimming Pool Therapy Pool Number of Bedrooms [] Well Only [] [] Water Storage [] [] Jacuzzi [] [] Water Softening Unit [] I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. ~erty owner or authorized agent) Permit Fees: ,~4./'~?po ,--.- Waiver Fees: Date of Payment: ~ ~ Date of Payment: Receipt Number: ~. ~ Receipt Number: ,..mev. 1~) ~t ~ ' ~ ~ND ENGINEERING, INC. 20441 PTARMIGAN BLVD. EAGLE RIVER, AK 99577-8736 (907)696-6111/FAX (907)696-8111 December 28, 2004 Municipality of Anchorage Development Services Department On-Site Water & Wastewater Program P.O. Box 196650 Anchorage, AK 99519-6650 Subject: Sewer Upgrade w! Lot-Line Waiver- Eklutna Heights, Stewart Addition, Lot 9 Gentlemen: The owner has requested we proceed forward to obtain a septic permit to upgrade and replace the existing septic system and tank for the subject lot. Per previous discussion with DSD staff, we propose that any bio-mat saturated soils encountered during construction is to be remov, ed and properly disposed of in accordance with municipal standards and clean material reinstalled per the attached design. The existing septic tank will be abandoned in place and in accordance with municipal standards. tO.n November 26, 2004 we dug one testhole for the proposed system. The results of his test are attached. The general slope of this lot is flat. We have designed our system utilizing the testhole we excavated for the 2-bedroom house. The lot is served by an individual well. We propose t.o install a 5' wide shallow trench. Water was not encountered during the excavation or monitoring. Due to the small lot sizes of the subdivision and close well radii, a 5' septic to lot line waiver is requested with this upgrade. There are no public or private wells within 200' of our proposed system location except as noted. There is no surface water within 100' of the proposed system and there are no known curtain drains within 50'. We do not expect t'here to be'any adverse effect on adjacent lots by the development of this system. If you have any questions, please contact me at 696-6111/FAX 696-8111. Respectfully submitted, ~.l~]I]) Engineering, Inc. -, P.E. Attachments: On-Site Well and Sewer Application Wastewater Absorption System Details!Site Plan Soils Log/Percolation Test Owner/Contractor Specs WELL & WASTEWATER I)ISPDSAL SYSTEM I)ETAILS/SITE PL EKLUTNA HTS, STEWART .ADI)N, LBT 9 LOT 17 ~' LOT 8 LOT 16 LOT 15 LOT 10 LOT 5 LOT 4 LOT ~ ;=' DDRH X 150 GPD= 300 GPD FLAG ALL ;,/ELL RADII 300 GPD/O.6 GPD PER SQ. FT. (16 MIN/IN.)= 500 SO. FT AND LOT LINES (500/5'(~/)) X 0.5 (re?) (4.0' GRAVEL) = 50 FT. TRENCH PRIOR TO CONSTRUCTInN USE I TRENCH - 50 (L) X 5' (V) X 4.0'(])) To'~ot dep'th oF sys~cem Is lO.O' max From orlglnat gr-de. To'l:0,l dep'l;h oF grovel below dlsi:rlbui:lon pipe I$ 4.0'. L CONTRACTOR IS TD REMOVE AND DISPOSE OF ALL BID-MAT AND SATURATED SOILS, THEN ADD LEVELING SAND IF NECESSARY TD TEN FEET FROM ORIGINAL GRADE. 2. PLACE PROPOSED SYSTEH IN LOCATION OR CLOSE PROXIMITY OF EXISTING SYSTEH AFTER THE ENGINEER HAS INSPECTED THE REMOVAL OF EXISTING SYSTEM AND THE OPEN TRENCH. 3. INSULATE TANK VITH 2' HD DURIAL FOAM IF LESS THAN FOUR FEET OF FILL. 4. CONTRACTOR %tILL ENSURE HINIMUH 27. SLOPE INTO SEPTIC TANK. 5. ADDITIONAL FILL ~/ILL DE ADDED OVER SYSTEM TO ACHIEVE MIN. 3' COVER IF REQUIRED. 6. EONTRACTGR ~/ILL ENSURE ALL OTHER SEPARATIONS TO ADJACENT VELLSo SEPTICS, LOT LINES, FOUNDATIONS AND ALL OTHER SETBACKS. · LANA GRIST ~ ~u5 04087.DW( ~ VBG ~ KMD 12/28/04 NW1460 04087 Scale, 1'= GO' PAGE 1 OF ~ T~) ENGINEERING 20441 PTARMIGAN BLVD. EAGLE RIVER, AK 99577-8736 oo:' 9 -si,IffXx {oo?too8-.lii WASTEWATER DISPrqSAL SYSTEM DETAILS EKLUTNA HTS, STEWART ADDN. LOT 9 ( ~ P. R~POSED ~ 1'00 GAL ,r,'"O~O~, LOT 8 X ID ~ ~04-1 ~ ~OT ~ ~ s,o~ ~ ~ s~o~[ = LOT 15~,2, ~~o' wE~ ~AD~ / FLAG ALL WELL _ RAD, ~ .Om U~ES ~ ~R~O~ mO CO,SmRUC~O, k~X~ LOT 10 AND LDT LINES ~ PRI~R TD C~NSTRUCT~BN · LANA GRIST 68B-3647 PAGE E BF 2 ~ NA I ~: ~o ENGINEERING ~-~~~ ~ NA ~ ~ ~0441 PTARMIGAN BL~. ~(~ssIO~ ~ ~r; NA mm 12/28/94 EAG~ R~ER, ~ 99577-8736 ]~D ENGINEERING, INC. 20441 PTARMIGAN BLVD. EAGLE RIVER, AK 99577-8736 SOILS PERCOLATION TEST Performed for: Lana Grist Date Performed: 11/26/04 Project: Depth (Feet) 3- 4- 5- 6- 7- 8- 9- 14- 19- 20- Eklutna Heights Stewart Addition, Lot 9 TEST HOLE # 04-1 Org GW/gm GM -med dense w/cobbles to 1' moisture increasing w/depth B.O.tI. SEE ATTACHED SITE PLAN FOR HOLE LOCATION Was Ground water encountered? NO Depth towater after monitoring? NO What depth? NA Date? 12/03/04 Reading Date Gross Net Depth to Net Time Time Water Drop 1 11/27/04 2:00 6" 2 2:30 30 mtn 3 15/16" 2 1/16" 3 ° 2:31 6" 4 3:01 30 mtn 4 2/16" 1 14/16" 5 ° 3:02 6" 6 3:32 30 mln 4 2/16" 1 14/16' * Water Added Percolation Rate 16 (mtn/in) Perc Hole Diameter 6' Test Run Between ~ feet and 6 feet I, Kenneth M. Duffus, certify that this test was performed in accordance with all State and Municipal guidelines in effect on this date. ~ND ENGINEERING, INC, 20441 PTARMIGAN BLVD. EAGLE RIVER, AK 99577-8736 (907) 696--6111 / FAX (907) 6968111 ON-SITE WASTEWATER DISPOSAL SYSTEM CONSTRUCTION PRACTICES AND MATERIAL SPECIFICATIONS LEGAL DESCRIPTION: EKLUTNA HEIGIFFS, STEWART ADDITION, LOT 9 GENERAL: 1. The scope of this project includes the installation of a septic tank and/or drainfield to serve a single-family residence on the referenced property as delineated on the attached Municipality of Anchorage (MOA) permit and site plan. . . 1. Construction shall be in accordance with the approved site plan and design drawings, MOA permit with any special provisions or conditions, and all applicable State and Municipal Wastewater Disposal Regulations. 1. KND Engineering, Inc (KND) as. sumes no responsibility of the accuracy of the as-built survey provided by the owner or owner s representative. 1. The owner or contract, or is responsible to notify the engineer of any discrepancies noted on the design plans or drawings prior to commencing work. These discrepancies could be, but not limited to, possible encroachments, surface water, varying soils, unplatted easements, types or use of dwellings on or adjacent to property, nearby public wells, etc. 1. The contractor shall be responsible for locating any necessary underground utilities, easements, property lines and surface water. The owner and/or contractor shall ensure, if deemed appropriate, that a registered land surveyor prior to construction flags all setbacks. 1. The contractor shall be responsible for verifying all pertinent separation distances and component layout. 1. Unless specifically agreed otherwise, the property owner shall be responsible for final grading areas subsequently depressed from soil settling. On all leachfield mound systems, the property owner shall be responsible for ensuring a satisfactory vegetation growth over the mounded area. 1. The MOA Development Services Department On-Site Water & Wastewater Program must certify contractors installing wastewater disposal systems. Owners installing their own systems must also receive prior approval from said MOA Department. SEPTIC TANK ! HOLDING TANK / LIFT STATION INSTALLATION: 1. A septic tank is to be constructed by a certified septic tank manufacturer. Construction shall include two 4" deanouts for pumping access. 1. The septic tank shall be sufficiently bedded with proper material and compacting to prevent damaging, settling or shifting of the tank. 1. All standpipes on the septic tank shall extend a minimum of 12 inches above the final grade. 1. Septic tanks installed with less than 4 foot of cover shall be insulated. The contractor will ensure that the fill over the tank does not exceed the burial depth rating. 1. A foundation cleanout shall be installed one to four feet from the building foundation. In the line between the tank and the leachfield there shall be two adjacent cleanouts (unless an effluent pumping system exists within the septic tank). These cleanouts shall be located on undisturbed soil not more than 10 feet from the tank. The second cleanout, in line, shall be to dean toward the septic tank. I. Final grading over the septic tank shall be such that a positive slope exists away from the septic tank. Reference: Eklutna }Its., Stewart Add. Lot 9 Date: 12/28/2004 Page: 2 of S 7. All H.D.P.E. tanks shall have a vertical length of 4-inch perforated drainpipe besides the tank extending to the bottom of the tank to above grade to monitor ground water. 8. All tanks shall be anchored when there is not enough adequate soil cover to resist buoyancy forces in high-groundwater areas. 9. All holding tanks and lift stations shall have an audible and visual alarm inside the residence. 10. Ail lift stations shall be wired in compliance with the Uniform Electrical Code and all MOA guidelines. 11. The contractor shall remove the old tank, or abandon it in compliance with the Uniform Plumbing Code. The contractor is solely responsible for the abandonment procedure. ABSORPTION TRENCH/DRAINFIELD INSTALLATION: 1. Excavate the proposed trench to the dimensions, shown on the design. The bottom of the excavation shall be within 2 inches of level. If the sidewalls of the excavaction become smeared, they must be raked or scratched (roughed-up) before grave! (sewer rock) pla.c, ement. 1. Once the sewer rock is installed, the distribution pipe is installed level with the perforations facing downward. Gravel is then to be placed over the distribution pipe to provide a minimum of 2 inches of cover over the pipe. 1. A silt barrier must be installed between the final gravel layer and the native soil backfill. Ensure the silt barrier covers the entire gravel surface before placing backfill. 1. Monitoring tubes shall be four- (4) inch diameter., installed approximately in the locations shown on the design, and extend a minimum of 12 roches above final grade. The portion of the monitoring tube extending through the gravel shall be perforated from the bottom of the trench to the invert of the distribution pipe. This is equivalent to the effective depth of the gravel as noted on the design. 1. Backfill over the final gravel layer must no.t be less than twenty-four inches. Insulation must be installed when the backfill depth is less than thirty-six (36) inches. The finish grade over the trench must be mounded to prevent the formation of a depression after settling. 1. All advanced technology waste water disposal systems (Advantex, Biocycle, Intermittent Dosing Sand Filter, etc...) shall be constructed, installed, maintained and monitored per manufacturer's specifications and MOA requirements. MINIMUM MATERIAL SPECIFICATIONS: 1. A MOA approved septic tank manufacturer must construct any septic tank proposed for installation. 1. The following pipe materials are MOA approved for use in septic system installations: T..vpe of Pipe Perforated ~lid Cast Iron Yes Yes ASTM D3034 (PVC) Yes Yes ASTM F810 (HDPE) Yes No ASTM D2662 (ABS) Yes Yes 1. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Company Styrofoam HI or equal). 1. Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Fernco, or equal). 1. A permeable nontoxic silt barrier (Typar 3401, Mirafi 140N, or equal) must be installed between the final leachfield gravel layer and the native soil backfill. - 1. Ail leachfield gravel (sewer rock) shall be 0.5"-2.5" screened gravel with less than 3% vassin~ the #200 sieve. If deemed necessary, a sieve analysis should be~performed. -" ° 1. When sand is being used as a filter material, its gradation specification must conform to current MOA or DEC requirements. Reference: Eklutna Ills., Stewart Add. Lot 9 Date: 12/28/2004 Page: :5 of 3 INSPECTIONS: Typically there will be. three (3) inspections required during the installation of the wastewater disposal system. These inspections will occur as follows: 1. The first ins.[~ection must be conducted after the excavation of ditche, s, pits, trenches, or beds and before me installation of any gravel. A septic tank may be set in place, but may not be backfilled before this inspection. 2. The second inspection must be conducted after the placement of the sewer rock, distribution lines, standpipes, and cleanouts, but before the placement of the silt barrier, insulation, or any other backfill. 3. The final inspection is to occur upon final grading of the property. Often there will be more than these 3 inspections required, especially with the installation of multinle trenches, sand filters, pressurized distribu' tion syster~s, etc. Th'e insp'ecting engineer is to be contact'ed at least 24 hours prior to the start of construction. If necessary, a pre-construction meeting will take place on-site. The inspecting engineer will not coordinate, direct or control in any way the contractor's activities. The owner shall con!ract with the contractor to perform the work outlined in these specifications and attached plans and m accordance with the attached. MOA permit. All materia!s, components, and construction practices shall comply with the MOA s and the State of Alaska s latest ordinances, regulations, or policies regarding wells and septic systems. The failure of the inspecting engineer to notice a material or construction non-compliance does not relieve the contractor of his/her responsibility to correct such deficiency. There will be no contractual arrangement existing between the contractor and KND Engineering, Inc. KND shall be the owner's representative and will inspect the work as stated above to document the contractor's activities. Final acceptance of the contractor's work rests with the owner and the MOA. KND shall have no liability to the owner or to others for acts or omissions of the contractor or any other persons performing work on this project or the fai!ure of the contractor to carry out the work in accordance with these construction documents. KND s inspecting engineer will not be responsible for the construction means, methods, and techniques, sequence, procedures or the safety precautions incident to this project. BY PROCEEDING FORWARD WITH TttE INSTALLATION OF TIlE WATER AND/OR WASTEWATER SYSTEM (S), THE PROPERTY OWNER, CONTRACTOR, AND WELL DRILLER ACKNOWLEDGES HAVING READ AND ACCEPTED TtIESE SPECIFICATIONS. Owner: Contractor: Municipality,?fAnchorag¢ P.O. Box 19C£~50 · Anchorage, Alaska 99-319-6650 · Telephone (907) 313-8301 · Fax (907) 31,3-8200 Mayor Mark Begfch Building Safety Division January I0, 2005 Brcnt Western KND Engineering 20441 Ptarmigan Blvd Eagle River, AK 99577 Subject: Waiver Request for Eklutna Heights, Steward Add, Lot 9 Waiver Request gWR050001 Parcel ID//051-063-26 P~.t,it Number SW050007 Dear Brcnt Western: Your request for a waiver of the required I0 feet horizontal separation from the absorption field fo properly line has been approved.' The approved separation distance is 5.0 feet. : This waiver approval applies to th6 existing absorption field to pwperty line separation only. Any future upgrade to the on-site wastewater disl~sal system will require all separation distances be, met or ano~er approval from'this department. If there are any further concerns or questions regarding this waiver, please call our office at 343-7904. ' .... ~ - - Sincerely, I ~4[2fvil Engineer On-Site Water & Wastewater Program Community, Security, Prosperity Municipality of Anchorage Development Services Department Building Safc~y Division On-Site Walcr and Was~ewatc~ Pwgram 4700 Bragaw Strcc~ P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchoragc.ak.us (9O7) 34309O4 Waiver Review Worksheet WR#: 050001 PID~: 1)~1-063-26 HA#: Permit~: =w050007 Date Received: 11t0/05 Legal Description: Eklutna Heiahts, Stewart Addition. Lot 9 Engineer:, ~9441 ptarmlaafl Bird Applicant: Lane Gflst Waiver Requested: 5 foot lot line waiver Cdteda: C-eolegy A. Water Table B. So~l Sorption C, Permeability D. WaterTable Gradient E, Horizontal Separation Total: Points: Waiver Is Granted: Waiver Is ne~ Granted: Ust Conditions or Reasons for above: Name of Reviewer Rec~: 52472 Amount: $175 Date Paid: 1/10/2005 i~ MUNICIPALITY OF ANCHORAGE ENVIRONMENTAL ENGINEERING DIVISION 825 L Street - Anchorage, Alaska 99501 Telephone 2~720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT LEGAL DESCRIPTION ~ ~°c~'°~2~ 7~ ~ ~: ~°.°~°°~ ~ Well Dwelling ~ PERMIT NO. ~ Manufacturer DISTANCE TO: /~ )'~ Material Liquid capacity in gallons =~ DISTANCE TO: Woll/~ f Found~tio~B / Neares~no ~ ~ = No. of lines/ Length olivine Total len~3lines Trench~ "inches Distance be~?n~ Total eff~ive absor~n ~ ~ ~ Top of tile to finis~de / Material beneath tile ~ inches Length Width Depth PERMIT NO. ~ Type of crib Crib diameter Crib depth Total effecti~ absorption area ~ Well Building foundation Nearest lot line ~ DISTANCE TO: ~ Class Depth Driller Distance to lot line PERMIT NO., ~ DISTANCE TO: Building foundation Sewer line Septic tank Absorption area(s) PIPE MATERIALS INSTALLER ~O ~ REMARKS 72-013 (Rev. 3/78) MUN I C I PAL I TY OF A DEPARTMENT OF HEALTH AND ENVIRONM~ 825 L STREET, ANCHORAGE~ A~. 264-4720 OR.~.SE~ _ PROTECTION 99501 ON--SITE SEWER & WELL PERMIT PERMIT NO: DATE ISSUED: 840609 07/23/84 APPLICANT: ADDRESS:' CONTACT PHONE: %S&S ENGINEERING IRA KRUGER SRB l~6X EAGLE RIVER, AK 9~577 6941979 LEGAL DESCRIP: LOT SIZE: MAX BEDROOMS: SUBDIVISION: EKLUTNA HTS. SECTION: 19 TOWNSHIP: 16N 8400 (SQ.FT. OR ACRES) LOT: ~ RANGE: 1E BLOCK: NA Listed below are the options available to you in designing your septic system. Choose the option that best fits your site. TRPNC|| BED DEPTH TO PIPE BOTTOM (FT.) 4.0 4.5 GRAVEL DEPTH (FT.) 6.0 0.5 TOTAL DEPTH (FT.) 10.0 5.0 GRAVEL WIDTH (FT.) 2.5 19.0 GRAVEL LENGTH (FT.) 58.0 56.0 GRAVEL VOLUME (CU.YDS.) 22.8 25.5 TANK SIZE (GALS) 1,000.0 ** 1,000.0 ** SOIL RATING (SQ.FT./BR) 150 150 ** TANK MUST HAVE AT LEAST TWO COMPARTMENTS DRAIN 4.0 5.5 7.5 5.0 49.0 ~ .36.2 1,000.0 ** 150 I certify that: 1. I am Familiar with the requirements for on-site sewers and wells as set forth by the Municipality of Anchorage (MOA> and the State of Alaska. 2. I will install the system in accordance with ail MOA codes and regulations, and in compliance with the design criteria of this permit. · 5. I will adhere to all MOA and State of Alaska requirements for the set back distances from any existing well, wastewater disposal system or public sewerage system on this or any adjacent or nearby lot. 4. I understand that this permit is valid for a maximum of 5 bedrooms and any enlargement will require an additional permit. IF A LIFT STATION IS INSTALLED IN AN AREA COVERED BY MOA BUILDING CODES, THEN (1) AN ELECTRICAL PERMIT AND INSPECTION MUST BE OBTAINFO; (2),AS-BUILTS WILL NOT BE AN ELECTRICAL INSPECTION REPORT; AND (5) THE ELECTRICAL WORK A LICENSED ELECTRICIAN. APPROVE~HOUT SIGNED ~ APPLICANT: KRUGER ISSUED BY ~__~ DATE: DATE: SOl LS LOG PERFORMED FOR: LEGAL DESCRIPTION: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 2O COMMENTS MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION 825 L. Street, Anchorage, Alaska 99501 264~1720 SOILS LOG - PERCOLATION TEST '~"~.f~, ~1~' ~.Jl.,[ ~, ~_. ~._ DATE PERFORMED: SLOPE SITE PLAN [] PERCOLATION TEST WASGROUND WATER ~ ENCOUNTERED? '~ O P IF YES, AT WHAT DEPTH? Gross Net Depth to Net Reading Date Time Time Water Drop ~'~ I"'/'' PERCOLATION RATE .~ .V~/~'~ (minutes/inch) TEST RUN BETWEEN FT AND -- FT PERFORMED BY: CERTIFIED BY: DATE: 72-008 (6/79) ~ICIPALITY OF A~CHORAGE DIVISION OF ENVIRO~C~iENTAL HEALTH DEPARTMENT OF HEALTH AND EhnIIRONi~ENTAL PROTECTION 1. General Information .~pplication Date (a) Legal ~esg.%iption__[iqclude lot, block, Location (address or directions) Applicants Address ~ ~ ~i~, ~/j-}~.~[~ (c) Applicant is (check one) Lending Institution t ~ , , Buyer ~--~ ; Other [ i (explain); (d) Lending Institution ....... Telephone Address (e) Real Estate Co. & Agent Address Telephone (f) Mail the HAA to the following address: Type of Residence Single-Family--. Number of Bedrooms Multi-Family ~--~ Other (describe) Water Supply / Individual Well t~-~ Community! ] Public I Note: If community well system, must have written confi~ation from the State Department of Environmental Conse.-":ation attesting to the ~eoalxty and status. Sewage Disposal Onsite ~,- Public I ! Community I~i ~olding Tank ~! Note: If community well system, must have written confirmation from the State Department of Environmental Conservation attesting to the legality and status. [Page I of 2] 5. En~ineerin~ Firm Providing Inspections~ Tests, File Search~ Data and Information As certified by my seal affixed hereto and as of the validation date shown below, i verify that my investigation of this Health Authority Approval shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that, based on the information obtained from the ,Municipality of Anchorage files and from my investigation and inspection, the on-si.~e water supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regula- tions in effect on the date of this inspection. Name of Firm Telephone DHETM A~roval Approved for /Z~/ bedrooms Approved ~ Disapproved Terms of Conditional Approval CAUTION THE :,IL.~ICIPALITY OF ANCHORAGE DEPARTMENT OF ~ALTH AND EknJIRO,'D~ENTAL PROTECTIOn; (DHEP) ISSUES :iEALTH AUTHORITY APPROVAL CERTIFICATES BASED SOLELY UPON THE P. EPRESEN~- ATIONS GIVEN IN PARAGRAPH 5 ABO~rE BY AN INDEPE.~;DENT PROFESSIONAL ENGINEER REGISTER~J) iN THE STATE OF ALASKA. THE DHEP DOES THIS AS A COLnRTESY TO Pb~RC~iSERS OF HOMES AND TitEIR LENDIZG INSTITUTIONS IN ORDER TO SATISFY CERTAIN FEDERAL ,~D STATE REQUIRE- MENTS. ~iPLO~ES OF DHEP DO NOT CONDUCT iNSPECTIONS OR A~ALYZE DATA BEFORE A CERTIFICATE IS ISSUED. TiIE MO~ICIPALITY OF .~CHCRAGE IS NOT iLESPONSIBLE FOR ERRORS OR OMISSIONS IN THE PROFESSiO~kL ENGINEER'S WORK. (DHEP SE~) RR4/ej/Di$ [Page 2 of 2] 7-19-84 A® MUNICIPALITY OF ANCF~RAGE (MO~) HEALTH AUTHORITY APPROVAL (HAA) CHECKLIST - FEBRUARY 1984 TAP..T .L DATA Well Classificatio/~ Well Log P=esent4Y~ Total Depth /~ ~- Case to Static Water Level ~-- Casing Height Above Ground Electrical Wiring in Conduit ((Y~ Separation Distances frcm Well: MUNICIPALITY OF ANCHOP, AOE DF?T. OF HEALTH & ENV~E~. ..... T,R_ . ,.,~CT[~N Leg~cr iption: SEPTIC~TAS~ [I~TA Date Installed si. % ~essi~ ~= Ta~ (Y~)/ ~%~d ~i~inte~n~ ~a~ ~ File (~)~/~; f~ ~/~ Holdi~ Ta~ Hi~te~ ~ (y~)----~ ~~ ~ldi~ Ta~ ~t (Y~)~/~/ ~ati~ Dist~s ~ ~ptic~lding Ta~: / TO ~te~Su~ly ~11 /~ To ~i!di~ F~ti~ TO ~rty ~ /~ To ~~ Field ~ ' To ~ter ~~i~ Li~ Course C~ti~=nts C_~-~3 ~. To~t~eam, Pond, Lake, cr Major Drainage [Page 1 of 2] :<: ~ Receipt # Date Paid: Amount: q~ 2-15-84 C. ABSORPTION FIELD DATA Soils Rating in Absorption ~t~ata Date Installed / ~ ~ Square Feet of Absorption A~ea Dep~ession over Field (Y/~ Results of Last Adequacy Test Separation Distance frcm Absorption Field: To Water-Supply Wall ~ To P~operty Line oFF / To Building Foun~atio~ Lot ~ /~%-' ; On Adjoining Lots To Water Maie~'Servi~e Line ~ { To Cutbank(if To Stream/PoDd/Lake/c~ Major Drainage Course To DriVeway,~ Parking .A~ea, c~ Vehicle Stc~age A~ea Cc~m~nts To Existing or Abandoned System cn LIFT STATION Date Installed Size in Gallons "Pump On" Level at High Water Alarm Level at Tested for Ele ct~ical Codes(Y/N) ~ ~leions /.Access (Y/N) ~/~~ Level at [/ Vent (Y/N) Pumping Cycles du~ing Adequacy Test. w~ets Comments ** Check Permitted Bed~ccm Rating Against HAA Request ** I certify that I have ~hecked, verified, c~. confc~ed to all MOA HAA on tbs date of this inspection. Signed ~~N~ Ccmpany ~ ~ KB1/O5/s [Page 2 of 2] t 2-15-84