HomeMy WebLinkAboutEKLUTNA WEST LT 1L
ANDERSON rENGINE`ERING
PO BOX 240773
ANCHORAGE, AIK 99524
December 1, 2005
MM&M Contracting
P.O. Box 670495
Chugiak, AK 99567
Attention: Arlene
Subject: Lot 1, Eklutna West Subdivision
Septic System Construction and Certification
Dear Arlene:
On June 22, 2005, a new absorption system composed of a 77' long x 3' wide x 8'
effective depth absorption trench was installed on the subject lot to dispose of the
septic effluent from the six -bedroom duplex. In addition, a new 2,000 -gallon septic tank
was installed to collect and treat the sewage generated in the house. All work was
completed in conformance with standards set by the State of Alaska Department of
Environmental Conservation and 18AAC 72.
The lot is served by the Dawn Water System, which is a community water system
regulated by ADEC. The current status of the water system is unknown, but it is
thought to be in conformance with ADEC requirements.
Attached is a copy of the State of Alaska Department of Environmental Conservation
Application for On -Site Water and Sewer System Approval and Documentation of
System Installation along with additional backup information. Please call if you have
any questions or require additional information.
Sincerely,
Michael E. Anderson, P.E.
Attachments
is-voui
Date Received
STATE OF ALASKA
DEPARTMENT OF ENVIRONMENTAL CONSERVATION
APPLICATION FOR ON-SITE WATER AND SEWER
SYSTEM APPROVAL
OR
DOCUMENTATION OF SYSTEM INSTALLATION
I. GENERAL INFORMATION
Source of Water and Containment (Check all that Apply)
Type of Water Supply Sys(cm
Legal Description of the Location
❑ Well (Drilled or Driven) [3urface (Identify)
❑ Private
Lot 1 Eldutna West S/D
❑ Roof Catchment
Annlicant Name:
❑ Holding Tank (—]Other (Identify)
Applicant is: (Check one)
❑ Other:
Michael E. Anderson
family)
❑ Bank
❑ Certified Installer. No.
Is a sanitary seal or well cap installed on the well casing? ❑Ycs ❑ No
Is drainage directed away from or around the casing within a radius of I(1 feet of the well casing? ❑ Yes ❑ No
❑Owner/hui Wer
■ Enghicer
Mailine Address
Sodic Water Level (Feet)
Tvpe of Residence:
Pump Rate (If available)
To(al Number of Bedrooms
P.O. Box 240773
Sewer Lines on Lot
Absorption Area on Lot
Plex
V
6
Closest Edge of an Absorption Area on Adjacent Lot
If toxic materials are stored on the property, including fuel tanks, paints, lubricants and other petroleum
❑ Single Family
Wtulfi-Familv
based materials, pesticides. fungicides or herbicides indicnte distance from con(nminants to well casing:
Cif V. State, Zin Code
Telenhone:
Sampler is:
Anchorage, AK. 99524
❑ Buyer ❑ Engineer
Address
i22-7773
Send Anprovalto:
Water Sample Results:
Attach Copy ❑ Satisfactory -Date ❑ Unsatisfactory - Date
❑ Applicanf .r Other (Bold for pickup by Michael E.
Anderson)
H. WATER SUPPLY SYSTEM
Source of Water and Containment (Check all that Apply)
Type of Water Supply Sys(cm
Treatment of Waler (Check all that Apply)
❑ Well (Drilled or Driven) [3urface (Identify)
❑ Private
❑ None ❑ Chlorination
❑ Roof Catchment
❑ Filtration ❑ Mineral Removal
❑ Holding Tank (—]Other (Identify)
❑ Public (Serves more than one
❑ Other:
family)
Well Data
Is the height of the well casing more the 72" above the ground? ❑Ycs ❑ No
Is a sanitary seal or well cap installed on the well casing? ❑Ycs ❑ No
Is drainage directed away from or around the casing within a radius of I(1 feet of the well casing? ❑ Yes ❑ No
Is well wire enclosed in conduit? ❑ Yes ❑ No
Date Drilled
Depth of Well (Feet)
Sodic Water Level (Feet)
Yield (If available)
Pump Rate (If available)
Separation Distance from the Well Casing to each of the Following Sources of Contamination:
Septic/Holding Tank on Lot
Sewer Lines on Lot
Absorption Area on Lot
Closest Septic/Holding Tank on Adjacent Lot
Closest Sewer Lines on Adjacent Lot
Closest Edge of an Absorption Area on Adjacent Lot
If toxic materials are stored on the property, including fuel tanks, paints, lubricants and other petroleum
On Lot
On Adjacent Lot
based materials, pesticides. fungicides or herbicides indicnte distance from con(nminants to well casing:
Water Sample Taken by: (Name)
Sampler is:
❑ Buyer ❑ Engineer
Address
❑ Banker ❑ Government Official
Water Sample Results:
Attach Copy ❑ Satisfactory -Date ❑ Unsatisfactory - Date
Comments/Recommendations:
Lot is Currently Served by the Dawn Water System. This System is Regulated by ADEC and It's Current Status is Unknown.
I certify that the above information and that provided in Section IV is correct:
Signature ` r Typed/PrintedNameDat
AA icy,
fitice
r`-Fro.c Michael E. Anderson
P.E. / CE -4381
a.
!Vote: Must be signed by a Cerliyzed Atstaller, Prof essioleal Engineer, DECstaff, or Owner/Builder
III. WASTEWATER DISPOSAL
Legal Description: Lot 1 Eklutna West SID
Septic Tank/Absorption System
❑ Package Treatment
fSpec ifv Brand Name or Process)
❑ Holding Tante- Specify
Capacity of Tank
Septic Tank Size (Gallons)
Where Waste is Disposed
Tqucncy of Pumping
Septic Tank Outfall Discharged To:
Subsurface
2
❑ Other (Specify):
(Outhouse, Incinerator, etc,)
M NEW SYSTEM
Name of Installer MM&M CONSTRUCTION
Date Installed 6/22/2005
Owner/Builder ❑ Certified Installer Other:
Septic Tank Type/Manufacturer
No. CONTRACTOR
STEEL / ANCH. TANK
Septic Tank Size (Gallons)
Number of Compartments
Soil Type and Rating GP -SP 190 S.F./BDRM
2000
2
Adequacy Test Performed by: (Name)
Type Soil Absorption System
Dimensions/Size Soil Absorption System
Type/Quantity Backfill Material Used for
DEEP TRENCH
3' X 77'X WEDISoil
Absorption System 80 CY .75"-3"
Percolation Test Results (Attach Copy of Report)
Percolation Test by: (Name) M. ELDRIDGENETECH
0.8 GPD/SF
Lot Linc
Minimum Ground Cover over
Minimum Ground Cover over
Cleanout Pipes/Caps Installed on
Cleanout Pipes/Caps Installed on
.Absorption Arca > 4'
Septic Tank > W
Septic Tank 0 Yes ❑ No
Absorption System 0 YES ❑ No
Separation i
Water Supply Source on Lo
Nearest Water Supply Source on
Nearest Body of Water
Water Table/Bedrock
Lot Line
Distance To:
NA
Adjacent Lot > 150'
> 100'
> 4'/6'
> 10'
Comments/Recommendations
FOUNDATION CLEANOUT PRESENT OUTSIDE OF FOUNDATION:
i
I certif • that the above information, and that provided in Section 1V is correct:
Signature �.,
r
Typed/Printed Name
Title, Reg./Cert No., Inst. No.
Date
�
Wil!i �LL�2 c <. 6t. -
'Zo
NOTE: Must be signed by a Certified Installer, Professional Engineer,, DEC staff, or approved OlvnedSuilder
LJ L'.i 1J 11lVV JYJII✓Lvl
Name of Installer
Datc Installed
❑ Owner/Builder ❑ Certified Installer ❑ Other:
No.
Septic7'anlc'I:ppc/,Manufacturer
Septic Tank Size (Gallons)
Number of Compartments
Soil Type and Rating
Type Soil Absorption System
Dimensions/Size Soil Absorption System
Type/Quantity Backfill Material Used for
Soil Absorption System
Adequacy Test Resulls (Attach Copy of Report)
❑ Pass ❑ Pail
Adequacy Test Performed by: (Name)
Date Septic Tank Pumped (Attach Copy of Receipt)
Minimum Ground Cover over
Absorption Area
Minimum Ground Cover over
Septic Tank
Cleanout Pipes/Caps Installed on
Septic Tank ❑ Yes ❑ No
Cleanout Pipes/Caps Installed on
Absorption System ❑ Yes ❑ No
Separation Water Supply Source on Lo
Distance To: I
Nearest Water Supply Source on
Adjacent Lot
Nearest Body of Water
Water Tablc/Iledrock
Lot Linc
Comments/Recommendations
I certify that the above information and that provided in Section IV is correct:
Signature Typed/Printed Name
Michael E. Anderson
Title, Reg./Cert No. a :'"`'-._T ^'
P.E. / CE -44' ^-_,
Nitc:::-
NOTE: Must be signed by a Professional Engineer. =
'S.
Re.-est-eqa si7fhal F " �` Yc t
Lnglhrer _..:.,:.
MONITOR TUBE
> 10'
E
C
LOT 1, EKLUTNA WEST S/D
PROJECT 4 M0545 PAGE I of 2
GENERAL N❑TESt
1. MAINTAINED 100 FOOT SEPARATION DISTANCE FROM
WELL ON LOT AND/OR ANY ADJOINING LOTS WELL,
2. MAINTAIN MINIMUM OF 10 FOOT SEPARATI❑N
FROM ANY PROPERTY LINES,
3, FOUNDATION CLEANOUT PLACED
WITHIN 3 FEET OF FOUNDATION,
SAS SIZINGi
6 BDRM X 190 SQ, FT./BDRM = 1140 SQ, FT, OF SAS REQUIRED
1140 SQ. FT. OF SAS = 71,25' TOTAL LENGTH OF TRENCH
2 X 8' ED
2 X 8' ED X 77' L = 1232 SQ. FT, OF SAS INSTALLEDi
2000 GALLON STEEL/ANCHORAGE TANK
SEPTIC TANK VENTS TWO (2) COMPARTMENT SEPTIC TANK
----------------------
1E---•-- ------ -
Top V ew
NO SCALE
LOT 1, EKLUTNA WEST S/D
PROJECT 4 M0545
PAGE 2 of 2
MOUNDED BACKFILL
OVER TRENCH
GROUND LEVEL——�I---
GEOTEXTILE FABRIC
6'
7p e
O
A7
d. O
e d
CAPPED 4' PERFORATED SEWER• O
PIPE HOLES DOWN .ROCK „
O
a
PERF. PIPE THROUGHOUT
TRENCH AREA d
' O
CAPPED CLEANOUT
CAPPED MONITOR TUBE
SOLID PIPE ABOVE TRENCH
l� I
I 4' GROUND COVER
O
d
a a e
. O
a'
O
BOTTOM OF TRENCH
8' EFFECTIVE DEPTH
OF SEWER ROCK
FOUNDATION
F
FOUNDATION CLEANOUT SEPTIC TANK VENTS TRENCH MONITOR TUBE -
/ (WITHIN 3' OF BUILDING) FERNCO TYPE TANK CONNECTOR
/ (TYPICAL) C/O
-
GROUND LEVEL
C/O
GEOTEXTILE FABRIC
FLOW 2000 GALLON
SEPTIC TANK
(LEVEL) CAPPED 4' PERF PIPE LEVEL HOLES DOWN
10' SOLID 4' AHS/PVC 10' SOLID 4' AHS/PVC SEWER ROCK HORIZON
PIPE 2 2X GRADE PIPE 8 27. GRADE
Side View
NO SCALE
6'
TO GROUND WATER
TO IMPERMEABLES SOILS//
//
End
View
NO SCALE
FOUNDATION
F
FOUNDATION CLEANOUT SEPTIC TANK VENTS TRENCH MONITOR TUBE -
/ (WITHIN 3' OF BUILDING) FERNCO TYPE TANK CONNECTOR
/ (TYPICAL) C/O
-
GROUND LEVEL
C/O
GEOTEXTILE FABRIC
FLOW 2000 GALLON
SEPTIC TANK
(LEVEL) CAPPED 4' PERF PIPE LEVEL HOLES DOWN
10' SOLID 4' AHS/PVC 10' SOLID 4' AHS/PVC SEWER ROCK HORIZON
PIPE 2 2X GRADE PIPE 8 27. GRADE
Side View
NO SCALE
Frontier Surveys, LLC Project No: 21-317 Date: 06/08/2021
Ordered By: Ally Hartman Plat: 72-186 Grid: 1461
Scalel"=30'
N89° 27'26"E 157.00'
10UTILITY EASEMENT
— Lot 1— —
Eklutna West Subdivision
r= —' —_ —■ —_ —_ —. 28,959 Sq. Ft. +/-
24335 Homestead Road
I 2 Story Wood Frame Duplex
With Attached 2 Car Garage
& 1 Car Garage
(S) iS)ii5{
I
I
to
a =
`D 78.2
54.0
x2
3 N
� X2 N N
� N
M
2
23.7 14.1,
0 13.0. 0 0...13.0 0
14.2
PAVED DRIVEWAY
my
_ 33'
R.O.W.
AK DOT R.O.W. TAKE
BK. 481, PG. 233
CULVERT
A
LT,
589.27' 26"W 71.99'
A
O�
_ EDGE OF PAVEMENT
l -
J
� – — C HOMESTEAD ROAD –
EDGE OF PAVEMENT
y Electric Meter/Outside Power —x— Fence LTA Tel. Pedestal
Gas Meter ® Deck p: Sign
�t g
`S, Septic Q Watervalve —ou—Overhead Utility
0 15 30 60
General Notes:
1. This document is created for the purpose of a single
property transaction and is subject to Federal Copyright Laws,
2. Excepting for gross negligence, the liability for this
survey shall not exceed the cost of preparing this survey. Scale in Feet
3. All measurements/setbacks are to the visual/apparent building footprint.
4. All dimensions to property lines are plus/minus 0.1ft.
This survey complies with the.ASPLS Mortgage Location Standards. The survey represents visible improvements and
1 OFt 1 t t
conditions at the time of the survey. This document does not constitute a boundary survey and is subject to any
A t I1
_ gss�i//
'
inaccuracies that a subsequent boundary survey may reveal. It is the responsibility of the Owner to determine the
_
p�. •
existence of any easements, covenants, or restriction which do no appear on the record plat. Under no circumstances
should this document be used for construction or for establishing a boundary or fence line.
Q '
H
As -Built Survey of.•
... .....
.. ...... .�
Lot 1 Eklutna West Subdivision
.............................:
Pi",
�� Fc
M.St gl•, ; 0j
Is -s rz ��
I, Pierre Stragier, hereby certify that this Mortgage Inspection Survey was performed by me, or
06/09/2021 J��_�
under my direct supervision on June 3rd, 2021.
rff�f�t�ROFESSIONAvv�.���
Frontier Surveys, LLCi FRONTIER,
650 W. 58th Ave. Suite E Anchorage, Alaska 99518
907.460.1686 - info@frontiersurveys.com
&"t�z
PROFESSIONAL SEAL
www.frontiersurveys.com
GREA,FR ANCHORAGE AREA BOR [GH
Department of Environmental Quality
3330 C Street
Anchorage, Alaska 99503
INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM
NAME ~/"~ /c-~/~/~''~ MAILING ADDRESS P~ [~/2'°/~ ~l~:~
LOCATION ~)FF'////~4~'~'2'~-/.~ ~__)~1~~. ~ LEGAL DESCRIPTION ,'~Jg~7"6
SEPTIC TANK:
DISTANCE
FROM WELt ~/1~)~' MANUFACTURER
INSIDE LENGTH
INSIDE WIDTH
T" MATERIAL
LIQUID DEPTH
NUMBER OF
' COMPARTMENTS t
LIQUID CAPACITY 4~''~O, GALLONS.
SEEPAGE 'P~:
NUMBER OF PITS __ DIAMETER __ OR WIDTH
LINING MATERIAL CRIB SIZE: DIAMETER__
BUILDING FOUNDATION , NEAREST LOT LINE__
LENGTH DEPTH
DEPTH DISTANCE FROM: WELL ~/g//¢/~'~4"~7' ~' ~
TOTAL EFFECTIVE ~)~.~
ABSORPTION AREA (WALL AREA) ~') SQ. FT.
ADDITIONAL ABSORPTION
WELL:
TYPE
BUILDING
FOUNDATION
CESSPOOL
APPROVED
-
CONSTRUCTION
NEAREST
LOT LINE /f~///~' ,
OTHER SOURCES
DISAPPROVED
NEAREST
SEWER LINE
DEPTH ~///~ DISTANCE FROM:
SEPTIC ~t,/'//'~ SEEPAGE
TANK , SYSTEM
REMARKS
DISTANCES:
INSTALLED BY:
piPe MATERIAL:C~3T ~-~?~/~
LOT SLOPE:
'I7pew~ H /ooI
DIAGRAM OF SYSTEM
DATE ~/~ ~/~' AP.ROVED
G.A.A.B,
GRE/ ~,'r ANChOrage Area Bo~ ,Jgh
DEPARTMENT OF ENVIRONMENTAL QUALITY
5330 "C" STREET ANCHORAGE, ALASKA 99503
TELEPHONE 274-456!
NAME OF APPLICANT
EGALDESCR'PT'ON
~NSTALLA¥~ON OF~ SEPTIC TANK BEEFAGE PIT
FINANCED THROUGH
SOIL TEST RESULTS
PERMit NO,
SEWAGE DISPOSAL SYSTEM -- APPLICATION AND PERMIT
MAILING f -
DRAIN FIELD OTHER .
! BE INSTALLED BY . /
"~O0 //~ p ID WITHOUT SOIL TEST
COMPLETION DATE ANTICIPATED
FINAL INSPECTION: 24 HOUR NOTICE REQUIRED. BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION BY THE
DEPARTMENT OF ENVIRONMENTAL QUALITY AUTHORITY WILL BE SUBJECT TO PROSECUTION.
SEFTIC TANK TYFE ~ ~ REA
MINIMUM DISTANCES, REQUIREMENTS
/
FOUNDATION TO SEPTIC TANK ~
FOUNDATION TO SEEPAGE PIT
SEPTIC TANK TO SEEPAGE PIT WALL
SEPTIC TANK ~
TO NEAREST LOT LINE,
· SEEPAGE PIT
WATER MAIN TO SEPTIC TANK
DRAIN FIELD
, DRAIN ~
SEEPAGE PIT ~/~) ~ I
ALSO CONSIDER AREA WELLS·
, SEEPAGE Pit
SEPT'O TANK, /~'"~Or SEEPAGE PIT ~dO~ , DRAIN FIELD /~O
TO RIVER, LAKE, STREAM.
CAST IRON INTO AND OUT OF SEPTIC TANK AND INTO CRIB CROSSING GAP OF
EXCAVATION 5 FEET INTO UNDISTURBED SOIL.
4 INCH DIAMETER CAST IRON SIPHON PIPES ON SEPTIC TANK AND SEEPAGE PIT
FITTED WITH AIRTIGHT REMOVABLE CAPS·. // .... ~
CONFORM TO BORO~GH~EGULATIONS REGARDING INSTALLATION.
DIAGRAM OF
I CERTIFY THAT I AM FAMILIAR WITH THE REQUIREMENTS OF GREATER ANCHORAGE AREA BOROUGH ORDINANCE NO. 28-68 AND THAT THE ABOVE
DESCRIBED SYSTEM IS IN ACCORDANCE WITH SAID CODE.
0 ~ E GEOTECHNICAL 8- DEVELOPMENT CO.
Box 90, Davis St., Eagle River, Alaska 99577
694-2774 or 688-2280
Russell Oyster
694-2774
Soils ~ Foundations
Earl Ellis
688-2280
Land Development
SOIL LOG
Perfomed for:
Legal Description: ~-~-~
Depth (feet)
0
Sot] Characteristics
5
6
7
8
9
10
11
12
Ground Water Encountered: Yes No
Proposed Installation: Seepage Pit
Comments: ~'-,~ ~--~.~.~
Perfomed by: h'~"~ ~.~,~
~'~'If yes, ~/depth
Drain Fte~d
Date:
-MUNICIPALITY -O - -NCH - - - - - - - ----
Development Services Department Phone: 907-343-7904
On -Site Water & Wastewater Section Fax: 907-343-7997
Certificate of On -Site Systems Approval
Parcel I.D. 051 062 60 Expiration Date:. O _ Z - Z 02 3
1. GENERAL INFORMATION
Complete legal description EKLUTNA WEST LOT 1
Location (site address) 24335 HOMESTEAD
Current property owner(s) BUXTON Day phone
Mailing address
Real estate agent Day phone
2. TYPE OF DWELLING:
0 Single Family (w/ADU)
❑ Duplex
❑ Multiple Dwellings (Single Family and/or Duplex)
3. NUMBER OF BEDROOMS: 6
4. TYPE OF WATER SUPPLY:
TYPE OF WASTEWATER DISPOSAL:
Private Well
❑
Private Septic
7
Water Storage
❑
Holding Tank
❑
Community Well
FA
Community
❑
Public Water System
❑
Public Sewer
❑
Waiver request for: NONE
Distance:
Received by:
Date:
COSA to be released to the engineer, unless otherwise requested by the engineer.
COSA Fee $ 5 50
Date of Payment (0 LAI L,2 0 � ,
Receipt Number 0 9 2Q 01b
COSA # O SC 01 1 3 � 5
Waiver Fee $
Date of Payment
Receipt Number
Waiver #
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based
on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the
on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of
bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the
Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater
disposal system is (are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in
effect at the time of installation.
Name of Firm C&M ENGINEERING
Address 20182 TULWAR
Engineer's Printed Name CHARLES BALZARINI
6. DSD SIGNATURE
System #1 Approved for _Le, -7 bedrooms
System #2 Approved for bedrooms
Disapproved
Phone 8545558
Date 6/10/21
of A/-
*: 49 TH * l
�j.. INARLES G BALZARINI .%
���'c��/•. CE -13854 .•��`��
Conditional approval for bedrooms, with the following stipulations:
-
WATER AN ri
W44 Q-
�� Q trVA-r,—
'"M)))))lilh��
y: Original Certificate Date: 6
The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the
representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is
not responsible for errors or omissions in the professional engineer's work.
7. ATTACHMENTS:
GOSA Checklist
Septic System Advisory
Well Flow Advisory
COSA Checklist blue sheet
X Nitrate Advisory
Arsenic Advisory
Other
COSA Checklist
Legal Description: EKLUTNA WEST LOT 1
If more than 1 septic system on lot: COSA Checklist # 1 of
A. WELL DATA
❑ Well log is filed with Onsite (or attached)
Date drilled
Total depth ft
Cased to ft
❑ Sanitary seal is functioning correctly
❑ Wires are properly protected
Casing height (above ground) in.
Date of flow test for COSA
Static water level at beginning of test ft.
Comments SERVED BY PUBLIC WELL
B. TANK DATA
Age of tank(s) 16 years
Tank type/material SEPTIC STEEL
Measured operating fluid level in septic tank 50
0 Standpipes/foundation cleanout per record drawing
Date of pumping
TANK LEVEL MEASURED PRIOR TO PUMPING
D. ABSORPTION FIELD DATA TRENCH
Which system tested (date installed) 2005
0 ALL standpipes present per record drawing
Total measured depth from grade 12 ft (max)
Measured depth to pipe invert from grade 4 ft (min)
❑ N/A — p�--�r-s�.ed-fteM
0 Monitor tubes go to bottom of effective. If not, state
depth into effective
0 Code -required soil cover over field
❑ System presoaked
(Required if vacant for greater than 30 days prior to
date of test)
Gallons introduced 750 gallons
Comments/Deficiencies:
COSA Checklist yellow sheet
Parcel ID: 051 062 60
Structure served by this system 1
Well production at time of test gpm
Water storage tank volume gallons
Well disinfected for coliform test? ❑ Yes ❑i No
❑ Coliform bacteria is Negative
Nitrate mg/L ❑ Nitrate less than MRL (ND)
Arsenic ug/L ❑ Arsenic less than MRL (ND)
Collected by
Date of Sample
C. LIFT STATION
❑ Required maintenance completed
Age of lift station years
Lift station material
Comments:
Adequacy test date 6/2/21
Results ❑✓ Pass For 6 bedrooms
Fluid depth prior to test 0 in
Water added 750 gal
New depth 0 in
Elapsed -time 1 min
Final fluid depth 0 in
Absorption rate 750 gpd
Any rejuvenation treatment (past 12 months)
If yes, enter date NA
NA
E. SEPARATION DISTANCES
From Private Well on Lot to: (Please enter distances if less than required or if community well)
Septic Tank/Lift Station on Lot > 100'
❑✓
Yes
Community Sewer Manhole/Cleanout > 100'
✓❑ Yes
if No
ft
M Yes
if No
Neighboring Tank > 100' ✓❑ Yes
if No
ft
Private Sewer/Septic Line > 25' 0✓ Yes
if No
Absorption Field on Lot > 100' ✓❑ Yes
if No
ft
Holding Tank > 100' 0✓ Yes
if No
Neighboring Absorption Fields > 100'
Yes
if No
Animal Containment > 50' E✓ Yes
if No
❑✓ Yes
if No
ft
Manure/Animal Excreta Storage > 100'
Community Sewer Main > 75' ✓❑ Yes
if No
ft
0 Yes
if No
From Septic/Holding Tank on Lot to: (Please enter distances if less than required)
Building Foundations > 10' 0 Yes if No ft Surface Water > 100'
ft
ft
ft
ft
ft
❑✓ Yes if No ft
Property Line > 5'
❑✓
Yes
if No
ft
Wells on Adjacent Lots:
Absorption Field > 5'✓Q
Yes
if No
ft
Private Wells > 100' ❑✓ Yes if No.
Water Main > 10'
F71
Yes
if No
ft
Community Wells > 200' Yes if No
Water Service Line > 10'
0✓
Yes
if No
ft
If septic tank is under driveway comment below
From Absorption Field on Lot to: (Please enter distances if less than required)
Building Foundation > 10' Il Yes if No ft If absorption field is under driveway comment below
Property Line > 10'
0
Yes
if No
ft
Wells on Adjacent Lots:
Water Main > 10'✓❑
Yes
if No
ft
Private Wells > 100' ❑✓ Yes if No
Water Service Line > 10'
❑✓
Yes
if No
ft
Community Wells > 200' Yes if No
Surface Water > 100'
0
Yes
if No
ft
F. ENGINEER'S COMMENTS
System was constructed when duplexes were under jurisdiction of the ADEC.
System was constructed with typical moa required features like after tank cleanouts
and drainfield cleanouts. Foundation cleanout is under back porch.
G. ENGINEER'S CERTIFICATION
/ certify that / have determined through field inspections and review
of Municipal records that the above systems are in conformance with
MOA COSA guidelines in effect on this date. 6/10/21
COSA Checklist yellow sheet
°F A/,,, l�
s*:49TM ••*fir
�. • CHARLES G BALZAR191
�� �'�c,•.• CE -13854 .••c����
11 `� '
`lliF�PR0FE QA, --
ft
ft
ft
ft