HomeMy WebLinkAboutEKLUTNA WEST LT 19
Rick Mystrom,
Mayor
Municipality of Anchorage
Department of Health and Human Services
825 "L" Street
P.O. Box 196650 Anchorage, Alaska 99519-6650
343-4?44
May 28, 1996
Eugene A Beaulieu
PO Box 671075
Chugiak, Alaska 99567
Subject: Lot 19 Eklutna West Subdivision
Permit 9SW950089, PID ~051-062-59
The subject permit, issued May 25, 1995 by this office for a
single family well and/or on-site wastewater system, has
expired as of May 25, 1996.
A new permit must be obtained from this office for a well
and/or on-site wastewater system NOT installed by the
expiration date.
If you have drilled the well, a well log must be sent to
this office for documentation of the installation and to
close the permit.
If a licensed Professional Engineer has inspected the
installation of the on-site wastewater system, the original
as-built inspection report must be sent to this office for
review, approval and documentation. All inspection reports
must be submitted within 30 days of construction completion.
When applying for a new permit, the fees are: $320.00 for an
on-site wastewater permit; $120.00 for a well permit and
$440.00 for a combined on-site wastewater and well permit.
If you have any questions, please call this office at 343-4744.
Sinc~rely,
g g
On-site Services
enc:
Copy of Permit
cc: S & S Engineering
PAGE 1 OF 1
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND HUMAN SERVICES
P.O. BOX 196650, 825 "L" STREET, ROOM 502
ANCHORAGE, ALASKA 99519-6650
ON-SITE WASTEWATER DISPOSAL SYSTEM (UPGP~ADE) PERMIT
PERMIT NUNiBER:SW950089
DESIGN ENGINEER:S & S ENGINEERING
OWNER NAME:BEAULIEU EUGENE A
OWNER ADDRESS:21246 SETTLERS DR
CHUGIAK, ALASKA 99567
PARCEL ID:05106259
LEGAL DESCRIPTION:
EKLUTNA WEST LT 19
LOT SIZE: 29625 (SQ. FT.)
NUMBER OF BEDROOMS: 2 THIS PERMIT: 2
THIS PERMIT IS FOR THE CONTRUCTION OF:
DISPOSAL FIELD /SEPTIC TANK SYSTEM
ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH:
DATE ISSUED: 5/24/95
EXPIRATION DATE: 5/24/96
1. THE ATTACHED APPROVED DESIGN.
2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS
15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL
REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80).
3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS
PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY
CALLING 343-4744 ( 24 HOURS ) (NOT REQUIRED FOR WELL ONLY PERMIT)
4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL
ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING
WEATHER MUST BE EITHER:
A. OPENED AND CLOSED ON THE SAME DAY
B. COVERED, SEALED AND HEATED TO PREVENT FREEZING
5. THE FOLLOWING SPECIAL PROVISIONS.
SPECIAL PROVIS IO~.
Tom Fink.
Mayor
unicipality of Anchorage
Department of Health and Human Services
825 "L" Street
P.O. Box 196650 Anchorage, Alaska 99519-6650
343-4744
May 27, 1994
Eugene A. Beaulieu
Po Box 671075
Chugiak, Alaska 99567 1075
Subject: Lot 19 Eklutna West Subdivision
Permit #SW930125, PID #051-062-59
The subject permit, issued May 27, 1993 by this office for a
single family well and/or on-site wastewater system, has
expired as of May 27, 1994.
A new permit must be obtained from this office for a well
and/or on-site wastewater system NOT installed by the
expiration date.
If you have drilled the well, a well log must be sent to
this office for documentation of the installation and to
close the permit.
If a licensed Professional Engineer has inspected the
installation of the on-site wastewater system, the original
as-built inspection report must be sent to this office for
review, approval and documentation. All inspection reports
must be submitted within 30 days of construction completion.
When applying for a new permit, the fees are: $320.00 for an
on-site wastewater permit; $120.00 for a well permit and
$440.00 for a combined on-site wastewater and well permit.
If you have any questions, please call this office at 343-4744.
Acting Program Manager
On-site Services Program
Copy of Permit
cc: S & S Engineering
PAGE 1 OF 1
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND HUMAN SERVICES
P.O. BOX 196650, 825 "L" STREET, ROOM 502
ANCHORAGE, ALASKA 99519-6650
ON-SITE WASTEWATER DISPOSAL SYSTEM (UPGRADE) PERMIT
PERMIT NUMBER:SW930125
DESIGN ENGINEER:S & S ENGINEERING
OWNER NAME:BEAULIEU EUGENE A
OWNER ADDRESS:il431 OLD GLEN HWY.
EAGLE RIVER, AK 99577-7729
DATE ISSUED: 5/27/93
EXPIRATION DATE: 5/27/94
PARCEL ID:05106259
LEGAL DESCRIPTION: EKLUTNA WEST LT 19
LOT SIZE: 29625 (SQ. FT.)
NUMBER OF BEDROOMS: 3 THIS PERMIT: 3
THIS PERMIT IS FOR THE CONTRUCTION OF:
DISPOSAL FIELD /SEPTIC TANK SYSTEM
ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH:
1. THE ATTACHED APPROVED DESIGN.
2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS
15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISP0SAL
REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80).
3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS
PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY
CALLING 343-4329 OR 343-4681 AFTER BUSINESS HOURS
4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL
ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING
WEATHER MUST BE EITHER:
A. OPENED AND CLOSED ON THE SAME DAY
B. COVERED, SEALED AND HEATED TO PREVENT FREEZING
5. THE FOLLOWING SPECIAL PROVISIONS.
SPECIAL PROVISIONS:
IF THE EXISTING SEPTIC SYSTEM IS A CESS POOL, IT MUST BE
PROPERLY ABANDONED. THE HEREIN APPROVED UPGRADE SYSTEM MUST
BE LOCATED NO CLOSER THAT TEN FEET FROM THE EXISTING SYSTEM.
RECEIVED BY: * DATE:
ISSUED BY:
ROBERT SHAFER, P.E.
ROGER SHAFER, P.E.
May 23, 1993
CIVIL ENGINEERS
(907) 694-2979
FAX 694-1211
HEALTH AUTHORITY
APPROVALS
SEWER & WATER
MAIN EXTENSIONS
SEWER & WATER
INSPECTION
ENGINEERING STUDIES
AND REPORTS
WELL INSPECTION
& FLOW TEST
SITE PLANS
ROAD DESIGN
SOIL TEST
Municipality of Anchorage
DEPARTMENT OF HEALTH AND HUMAN SERVICES
825 L Street
Anchorage, Alaska 99501
REFERENCE: Eklutna West Subdivision, Lot 19
Request you issue a permit to upgrade the septic system
serving the referenced property.
.The existing system is undocumented.
A test hole was excavated and a percolation test performed
in the area of the proposed upgrade. Attached is the
proposed upgrade design.
There are no protective well radii which encroach upon the
property. As can be seen from the site plan this lot is
large enough for another future upgrade. We do not
anticipate any adverse effects on neighboring properties by
the installation of the proposed septic upgrade.
If you have any questions or require additional information
for your please contact us.
A. Shafer, P.E.
PERCOLATION
TEST
STRUCTURAL &
MECHANICAL
INSPECTIONS
ON SITE
WASTE WATER
DISPOSAL SYSTEM
DESIGN
17034 NORTH EAGLE RIVER LOOP" SUITE 204 · EAGLE RIVER, ALASKA 99577
(13=llSOd) ':1^1~1(] S~13'1113S (1¥9d) 133HIS H33NOId
g._.._. ~
7
/
~ t
N¥-ld 3.LI~
PERFORMED FOR:
Municipality of Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L" Street, Anchorage, Alaska 99502-0650
SOILS LOG -- PERCOLATION TEST
4
5
6
8
g
12
13,
14--
17-
"18
lg
2O
~-I~..T["~ ~ ~,~.~ Township, Range, Section:
SLOPE
WAS GROUND WATER~'~'LO
ENCOUNTERED7
IF YES, AT WHAT ~.~ ~
DEPTH? P
E
Depth to Waler qAfter ~ ,,~ i~ ..~.~
Monitoring? ~0 ~ Date:
SITE PLAN
Gross Net Depth to Net
Reading Date Time Time Water Drop
PERCOLATION RATE ~, C) (minutes/inch) PERC HOLE DIAMETER
TEST RUN BETWEEN --~FT AND ~ FT
COMMENTS ?-~- ? I~NG!NEI~RjN(~ / /
I zu.~i Eagle River Loop Road NO. 204
PERFORMED BY: ...... · z ~~TIFY THAT THiS TEST WAS PERFORMED IN
ACCORDANCE WITH ALL STATE AND MUNICIPAL GUI~FECT
ON
THIS
DATE.
DATE:
72-~8 (Rev. 4/~)
Municipality of Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L" Street, Anchorage, Alaska 99502-0650
SOILS LOG -- PERCOLATION TEST
PERFORMED FOR:
LEGAL DESCRIPTION:~
DATE PERF{
~. ~Z-~.).~'~ I~. '~.<.¢Township, Range, Section:
5
6
7
8
9-
10-
11
12
13
14
15
16
17
18
19
20
SLOPE
WAS GROUND WATER ~,
O
ENCOUNTERED?
IF YES, AT WHAT i~L t
DEPTH? pO
E
SITE PLAN
Depth to Water ~er
.\ .
Monitoring? ~.¥'~ v~Z.,'" Date:
Gross Net Depth to Net
Reading Date Time Time Water Drop
PERCOLATION RATE \~ (minutes/inch) PERC HOLE DIAMETER ~
TEST RUN BETWEEN '~'----'-4:t AND ~'- FT
COMMENTS ~7~A ~!e ........ ~ ..;=. ,.G. ~ - -
PERFORMED BY: ~~ CERTIFY THAT THiS TEST WAS PERFORMED IN
ACCORDANCE WITH ALL STA~E AND MUNICIPAL GU~/~EF~ ~ ~lS ~T[ DATE;
72-~8 (Rev, 4/85) ~
ON-SITE #ASTEWATER DISPOSAL SYSTEM
CONSTRUCTION PRACTICES
and
MATERIAL SPECIFICATIONS
REFERENCE: Eklutna West Subdivision, Lot 19
GENERAL:
1.
The scope of this project includes the installation of a
1000 gallon septic tank and a 5' wide drainfield to serve
the three bedroom residence proposed for the referenced
property.
Construction shall be in accordance with the approved
site plan and design drawings; Municipal permit with any
special provisions or conditions; and all applicable
State and Municipal Wastewater Disposal Regulations.
The contractor shall be responsible for obtaining any
necessary underground utility locates.
Unless specifically agreed otherwise, the property owner
shall be responsible for final grading areas subsequently
depressed from soil settling. On all leachfield mound
systems, the property owner shall be responsible for
ensuring a satisfactory vegetation growth over the
mounded area.
Contractors installing wastewater disposal systems must
be certified by the Municipal Health Department for
system installations. Owners installing their own
systems must also receive prior approval from the
Municipal Health Department.
SEPTIC TANK INSTALLATION:
A septic tank is to be constructed by a certified septic
tank manufacturer. Construction shall include two 4"
cleanouts for pumping access.
The septic tank shall be sufficiently bedded to prevent
settling or shifting of the tank.
Ail standpipes on the septic tank shall extend a minimum
of 12 inches above final grade.
4. Septic tanks installed with less than 4 ft. of cover
shall be insulated.
page 2
Eklutna West Subdivision, Lot 19
0
6e
A foundation cleanout shall be installed one to four feet
from the building foundation. In the line between the
tank and the leachfield there shall be two adjacent
cleanouts (unless an effluent pumping system exists
within the septic tank). These cleanouts shall be
located on undisturbed soil not more than 10 ft. from the
tank. The first cleanout, in line, shall be to clean
toward the leachfield. The second cleanout shall be to
clean toward the septic tank.
Final grading over the septic tank shall be such that a
positive slope exists away from the septic tank.
ABSORPTION TRENCH/DRAINFIELD INSTALLATION:
Excavate the proposed trench to the dimensions shown on
the design. The bottom of the excavation shall be within
2 inches of level. If the sidewalls of the excavation
become smeared, they must be raked or scratched (ruffed-
up) before gravel (sewer rock) placement.
Once the gravel is installed, the distribution pipe is to
be installed level with the perforations faced downward.
Gravel is then to be placed over the distribution pipe to
provide a minimum of 2 inches of cover over the pipe.
A silt barrier must be installed between the final gravel
layer and the native soil backfill. Ensure the silt
barrier covers the entire gravel surface before placing
backfill.
Monitor tubes shall be of four (4) inch diameter and
installed approximately in the locations shown on the
design. The portion of the monitoring tube extending
through the gravel shall be perforated from the bottom of
the trench to the invert of the distribution pipe. This
is equivalent to the effective depth of the gravel as
noted on the design.
50
Backfill over the final gravel layer must not be less
than twenty-four (24) inches. Insulation must be
installed when the backfill depth is less than thirty-six
(36) inches. The finish grade over the trench must be
mounded to prevent the formation of a depression after
settling.
page 3
Eklutna West Subdivision, Lot 19
INSPECTIONS~
Typically there will be a minimum of three (3) inspections
required during the installation of the wastewater disposal
system. These inspections will occur as follows:
The first inspection must be conducted after the
excavation of ditches, pits, trenches, or beds and
before the installation of any gravel. A septic
tank may be set in place, but may not be backfilled
before this inspection.
The second inspection must be conducted after the
placement of the silt barrier, gravel, distribution
lines, standpipes, cleanouts, and insulation, but
before the placement of any other backfill.
The final inspection is to occur upon final grading
of the property.
Often there will be more than these 3 inspections required.
Especially with the installation of multiple trenches, sand
filters, pressurized distribution systems, etc. Thus, the
inspecting engineer is to be contacted at least 24 hours prior
to the start of construction. If necessary, a pre-
construction meeting will take place on-site.
MINIMUM I~%TERIAL SPECIFICATIONS:
Any septic tank proposed for installation must be
constructed by a Municipally approved septic tank
manufacturer.
The following pipe materials are approved for use in
septic system installations in the Municipality of
Anchorage:
Type of Pipe
Perforated Solid
Cast Iron
ASTM D3034 (PVC)
ASTM F810 (HDPE)
ASTM D2662 (ABS)
Yes Yes
Yes Yes
Yes No
Yes Yes
Use of a type of pipe other than listed above must be
approved by the inspecting engineer.
page 4
Eklutna West Subdivision, Lot 19
Insulation shall be at least 2" thick extruded direct
burial polystyrene (Dow Chemical Company Styrofoam HI or
equal).
Septic tank inlets and outlets shall be fitted with
watertight couplings (Caulder, Fernco, or equal).
A permeable nontoxic silt barrier (Typar 3401, Mirafi
140N, or equal) must be installed between the final
leachfield gravel layer and the native soil backfill.
Ail leachfield gravel (sewer rock) shall be 0.5"-2.5"
screened gravel with less than 3% passing the #200 sieve.
When sand is being used as a filter material, it's
gradation specifications must conform to AMC 15.65.060D.