HomeMy WebLinkAboutELMORE #2 BLK 9 LT 10 Municipality of Anchorage Page 1 of 2 DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P,O. Box 196650 Anchorage, Alaska 99519-6650 Telephone: 545-4-744- On-Site Wastewater Disposal System and/or Well Inspection Report Permit Number: SW990525 PID Number: 018--175--22 ~ame:RiCK MOODY Wastewater System: [] New · Upgrade Address: 4,351 E. 147TH ANCH. AK, 99516-4110 ABSORPTION FIELD No. of Bedrooms: Ph°ne:(907) 545--1999 5 DDeep Trench gShallow Trench .Bed DMound nOther LEGAL DESCRIPTION o.7 aPb/s,. ~ *3.62 (MAX.) ~ 10 9 ELMORE #2 0.57 .- 0.65 - - - 2.1 F~ 45 .. r~! ANCHORAGE EXC. 9/16/99 - 9/22/99 p, .. TANK SEPARATION DISTANCES "Septic m .oldlng n S.T.E.P. To Septic Absorption Uft Ho]ding ~ublic/Pr~vab Manufacturer:, Capacity In gallons: -rom Tank Field Station Tank Sow,r U,,, ANCHORAGE TANK 1000 We~l 100'+ 100'+ - 25'+ STEEL 2 S,¢ace 100'+ 100'+ - - LIFT STATION Water Lot 5't- 10'+ -- - ~z° in gall°"s:I Line Foundation 5'+ 10'1. I I Remar~: * 2'-~" O~ ~.O.^. ~,TE, S^NO WAS ~NST^,LEO. BENCH MARK BOTI'OM STEP OF STAIRCASE OFF THE WEST SIDE OF THE HOUSE. ,nspeotions performed by: AWWC, INC. Dates:lst 9/16/99 ~'" ~-~-~-~ .... 2nd 9/17/99 ~ ~'" ) , 4th 9/2,/99 lO~¢]';J.' /,~-7953 ...'~ of Health and Human Services approval ~(~%:;:.,~,~ .......... Department Reviewed and approved by: /]~//x//~ ~ //-/, /~¢~-~t~ Date: ¢'.~-. ~'~'.¢' ~,~'~,~of.e¢o~' DBL1 26,5 2~,1 - DB~ 27,5 22,8 - MT2 I - 112,8 132,2 ~ cO~ ~ ~ ~ ~ ~ t ~2 ~ /FCO~ ' ~ffr~ : E. 147TH AVENUE ~AS~ WATER ~ WASTEWATER CONS~T~TS, ~C. AS-BUlkY OF SEPTIC SYSTEM UPGRADE [-~. ~ ~ ...... 9...:-...~ PREPPED FOR: PHONE NUMBER; DATE:9/27/99 O~WN BY: sc~: PAGE: K.D.W. 1 = 40' 2 OF 2 MUNICIPALITY OF ANCHORAGE Department of Health and Human Services On-Site Services Program 825 L Street, Room 502 P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-4744 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Upgrade Permit Number: SW990325 Legal Description: ELMORE#2 BLK 9 LT 10 Design Engineer: 0041 AK Water & Wastewater Consulta Owner Name: Rick Moody Owner Address: 4351 E 147TH Date Issued: Sep 09, 1999 Expiration Date: Sep 08, 2000 Parcel ID: 018-173-22 L"~ C,~_~.,:~\-ovot Site Address: 004351 147TH AVE E Lot Size: 39520 SQ. FT. Total Bedrooms: 3 Permit Bedrooms: 3 ANCHORAGE , AK 99516-4110 This permit is for the construction of: [] Disposal Field [] SepticTank [] Holding Tank [] Privy [] Private Well [] Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DHHS at least 2 hours prior to each inspection. Provide notification by calling (907) 343-4744 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. 5. The following special provisions. THE SAND USED IN THE FILTER LAYER MUST BE A CLEAN COARSE SAND WITH 4% OR LESS PASSING THE #100 SIEVE AND 2% OR LESS PASSING THE #200 SIEVE. A SIEVE ANALYSIS MUST BE PROVIDED ON THE SAND USED OR OBTAINED FROM AN APPROVED SOURCE. Received By: ~/~J(~/L~ ~('.5~5~ Date: Date: Alaska Water & Wastewater Consultants, Inc. 6901 Debarr Road, Suite 2B N Anchorage ~ Alaska 99504 (907) 337-6179 ~ Fax (907) 338-3246 Consulting Engineers September 1, 1999 Municipality of Anchorage Department of Health & Human Services Division of Environmental Services On-Site Services Section P.O. Box 196650 Anchorage, Alaska 99519-6650 Ref: Septic Upgrade Design for Lot 10, Block 9, Elmore Subdivision #2 To whom it may concern: The existing 3 bedroom house is served by a private well and a private septic system. The existing septic system consist of a 1000 gallon septic tank and a crib type drainfield that is in groundwater; consequently, it must be upgraded prior to the sale of the house. Two test holes were excavated. The proposed septic system will be designed around the 30 foot radius of test hole #2. Comments regarding the proposed design are summarized as follows: 1. SOILS: Attached are logs which shows the soil profile, and the percolation test results. Due to the better soil conditions in TH#2, we are proposing that the new drainfield be installed around the 30 foot radius of this test hole. In TH#2, the soils below the organics are a GW material to a depth of 9 feet (bottom of test hole #2). Groundwater was encountered during the excavation at 6.8 feet and was 5.88 feet below grade 7 days later. A percolation test was performed between the depth of 3.0 feet to 4.0 feet which had a percolation rate of <1 minute/inch. A M.O.A. approved sand filter will need to be used. 2. TRENCH DESIGN: a. Percolation Rate: <1 minutes/inch b. Allowable Application Rate (Sand Filter): 0.7 gallons/day/ft2 c. Number of Bedrooms: 3 d. Design Flow: 450 gallons per day e. Minimum Absorption Area: 643 122 f. Total Depth: 3.75 feet (max.) g. M.O.A. Approved Sand Filter: 2.5 feet h. Effective Depth: 0.5 feet i. Width: 15 feet ~ Minimum Length: 45 feet long . Effective absorption area = 675 122 3. SURFACE WATERS: There are no surface waters within 100 feet of the proposed upgrade. 4. TOPOGRAPHY: As can be seen on the topography site plan, the lot slopes east to west at approximately a 3 pement slope; in short, there are no slope concerns. I am unaware of any adverse impacts this installation would have on adjacent wells or septic systems. If you have any questions, please contact mc at 337-6179, or 244-9612. Thank you for your assistances/ ;;~eJJsiedY~nt .i tamess, P.E., M.S. NOTE: Attached is a site plan drawing, a design drawing, two soils logs, a topography site plan and a 4 page construction specification letter which are all part of the design package for this septic system. / / \ / \ /J~ NOTE: THE CONTRACTOR SHALL HAVE THE WEST / I PROPERTY LINE. SOUTH PROPERTY LINE. AND THE 100 FOOT WELL RADIUS FLAGGED BY A / I RECiSTE.eD LAND SURVEYOR PRIOR TO AN~ ~ 5XX\ EXISTING SEPTIC TANK TO I~ / 3EXISTING / '~ >- I \ BE COMPLDELY ~DONED~ ~ / BEDROOM ~ ~ ~ ~ ~ ~ / HOUSE ~ ~MT ~ ~ (~, LOCATION) / ~G~ < I CO __ I / OF BLUE BO~D INSU~ON~ ~ o~ ~.o.~. ~,~ow~ ~ E. 147TH AVENUE PHONE: (907) 337-6179/F~: (907) 338-32~6 ELMORE SUBDIVISION ~3; LOT 10, BLOCK 9, DESIGN OF SEPTIC SYSTEM UPGRADE · ..:' ~, ~ff~e~ A~ness.. PREPPED FOR: PHONE NUMBER: .....'~ .~cK UOODY (.07) ~5-~ 99~ ~'~. ~-7~5~ DATE:9/1/99 D~WN BY: SCA~: PA~E: J.L.M. 1 = 30' 2 OF 2 ELMORE S/D / ELMORE ~2 S/D ~ ~ LOT 3, BLOCK 9 I I / / x J ~ ~---~- I / E. 147TH AVENUE (SEE DESIGN, PAGE 2 OF 2) I I ELMORE ~2 S/D E~ORE ~2 S/D ELMORE ~2 S/D ~ I ~AS~ WATER ~ WASTEWATER CONS~T~TS, ~C. ELMORE SUBDIVISION ~2, LOT 10, BLOCK 9, SITE P~N FOR SEPTIC UPGRADE 345-1999 J.L,M.~ 1 = 100' 1 OF 2 ALASKA WATER & WASTBWATER CONSULTANTS, INC. ~'~- 69o~ DE,*R, ,o~. surrE 2, * ~CHO,A~. ^K. 9~504~.~-~--.. - --~"~'~'r:"':~" · [SOIL LOG - PERCO~TION TEST] ~?I~ZB~[ '~ PERFORMED FOR: RICK ~OODY [:~d~ ~,~ '~n~:""~ [TEST HOLE ~1 [ "h~:.o;. ] / .... SP-SM i' II I~ ~NO ~ ~ / 7 ~, ¢¢r DEPTH TO ~ ".o%~ W/~/ GROUNDWATER DATE P~O OSED o°~o~o° S ~ SEP~C 0¢o%o~ 8.5' 8/25/99 I00' / E. 14~H AVENUE [ B~.H. I qO ~ ~1 DAT~ ~DING C~OCK N~T T]H~ W~T~R ~V~ N~T DRO? ~2 ~4 N ) P~RCO~TiO ~ P~RR 18 ~9 ~CO~ATION ~T~ - (~IN./iNCH) ?~C. HO~ DiA. - ONCH~S) 20 T~ST ~UN 8~TW~N - FT. ~ND - FT. CO~NTS: ML ~Y~R W~ ~SO~Y ~0 TO ~ IM~RM~L~. US~ T~ HO~ ~2 FOR PRO?OS~O UPG~DE. PERFORMED~Y/A~S~ WATER · W~T~ATER, I, JEFFR~ A. GARNESS, CERTI~ THAT THIS W~ PERFUMED IN ACCORDANCE WITH ALL ~ATE AND MUNICIPAL GUIDELINES IN EFFECT ON DATE; DEPTH TO GROUNDWATER DATE 8.5' 8/25/99 ALASKA WATER & WASTEWATER CONSULTANTS, INC. 6901 DEELARR ROAD. SUITE 28 * ANCHORAGE, AK. 99504 ,.O.E · ISOIL LOG - PERCOLATION TEST I ~;..-~fi/~¢-~,~- ....~v~, PERFORMED FOR: RICK MOODY DATE PERFORMED: 8/25/99 7~2"~. i E-7953 ..," ~ [TEST HOLE #2[ foot) 2-- S SSI 0 S :;~.~,:~.~,, GW ..... ORG :~:~;.,~ ~:- ~ GP HL ~ ~ BEORROM)EXISTING ~ SW ~ HH ~l l. SEP~C . ~ / 7-- ~:;:~'~? ~ DEPTH TO DATE ~ ' ~':~?~;'~ GROUNDWATER ~PROPOS[D ~'~ JSiTE PLAN 8 .......... ,, 8/25/99 -UP~D[~ -,.~%,~.~',- / I" = I00 E. 147TH AVENUE :;;%:~:~:.~ 6.1' 8/26/99 S.O.~. 5,9' 9/2/99 i --- ~ 10-- ~ II I 11-- DATE READING CLOCK NET TINE WATER LEVEL NET DROP TINE (HINUTES) READING (INCHES) 12-- __ 18-- 17-- _1}~1~~ ~ lg- PERCOLAT~ON RATE <1 (MIN./INCH) PERC. HOLE DIA. 6 (}NCHES) 20 TEST RUN BETWEEN ~.0 FT. AND 4.0 FT. COMMENTS: M.O~ ~PROVED ~D ~L~R WILL BE REQUIRED. PERFORMED BY A~S~ WATER · W~T~ATER. I, JEFFR~ A. ~ARNESS, OERTI~ THAT THIS W~ PERFO~D IN AOOORDANOE WITH ALL STATE AND MUNICIPAL ~UIDEMNES IN EFFECT ON DATE: ~/~/~ DEPTH TO DATE GROUNDWATER 6.8' 8/25/99 6.1' 8/26/99 5.9' 9/2/99 A l~zG Inc., Xepteraber 1999 Alaska Water & Wastewater Consultants, Inc. 6901 Debarr Road, Suite 2B ~ Anchorage -Alaska 99504 Phone (907) 337-6179 ~ Fax (907) 338-3246 Onsite Wastewater Disposal System Standard Construction Specifications I. REFERENCE PROPERTY: Elmore Subdivision #2; Lot 10, Block 9, II. DEFINITIONS: 1. Property owner: The legal property owner or his/her representative. 2. Engineer: Alaska Water & Wastewater Consultants, Inc. or AWWC, Inc. 3. Contractor: The company hired by the property owner to install the septic system. 4. DHHS: Municipality of Anchorage, Department of Health & Human Services 5. M.O.A.: Municipality of Anchmage, Department of Health & Human Sen, ices III. RESPONSIBILITIES: · Property Owner Responsibilities: 1. The property, owner shall contract with the contractor to perform the work outlined in these specifications and plans, in accordance with the attached DHHS permit. There is no contractual relationship between the contractor and the engineer. The engineer shall inspect the work as, required by DHHS to document the installation. Final acceptance of the contractor's work rests with the owner and the DHHS. 2. This well and/or septic system design is for a single family residence only. The homeowner is responsible for notifying the engineer if the residence is used as a duplex, business, or multi-family dwelling. In such cases, the installation pernfit must be obtained from the State of Alaska, Department of Environmental Conservation. 3. The validity of the design site plan is limited by the accuracy of the as-built survey provided to the engineer by the property mvner or his/her representative. The property owner shall notify the engineer regarding any known inaccuracies associated with the as-built survey. The engineer assumes no responsibility for the accuracy of the survey. 4. The property owner is responsible for notifying the engineer of any unplatted easements, not shown on the as-built survey, which the new well or septic system may encmach into. 5. The property owner shall notify the engineer of any seasonal groundwater or surface water runoff conditions, known to him/her, which could potentially effect the operation of the septic system. The proposed septic system must be at least 100 feet from any streams, ponds, creeks, swamps, bogs, or any other surface water as de£med by the DHHS. 6. The property owner is responsible for notifying the engineer if, to his/her knowledge, any of the adjacent properties are used as a duplex, business, or multifamily dwelling. The new septic tank and leachfield must be at least 100 feet fi'om any private well, 150 feet from any class "C' well, and 200 feet from any community well, unless appropriate waivers are obtained. 7. The property owner and/or his contractor shall report to the engineer any observed condition which would put the septic system in violation of State or Municipal regulations. 1 of 4 AWWC, Inc., September 1999 8. Unless specifically agreed upon otherwise, the property owner is responsible for final grading of the areas which settle after construction. Prior to awarding the contract, the homeowner should communicate to the contractor any expectations regarding, but not limited to, post construction site clean-up, re-landscaping, and restoration of any asphalt, fences, trees, decks, ect. that are effected by the construction. If the property is being sold, the property owner shall ensure that the aforementioned items are addressed with the buyer, and, if the work is to be completed after the sale of the property, that necessary funds are escrowed to fund the completion of the work. 9. If the property o~vner intends to install the septic system he/she must first have obtained approval from the Municipality of Anchorage, DHHS (343-4744). Homeowner installations typically require more time for engineer inspections. The homeowner should discuss the additional costs, associated with such inspections, with the engineer, prior to starting the project. 10. The property owner is responsible for payment of all the engineer inspection charges. The number of inspections will vary depending on the actual field conditions encountered and the construction methods used. · Contractor Responsibilities: 1. The contractor is responsible for locating all buried utilities, easements, property lines, and surface waters; and shall ensure that ali setbacks are flagged by a registered land surveyor prior to construction. 2. Construction shall be in accordance with the approved site plan and design drawings, and any special provisions noted on the municipal sewer permit. The contractor is responsible for notifying the engineer of any discrepancies noted on the design plans or drawings, prior to starting work. The installation, materials, and workmanship shall comply with all applicable State & Municipal regulations. 3. The contractor is responsible for field verifying the separation distances to all adjacent wells and septic systems, shown on the design drawings, prior to starting construction. Any encroachments that would effect the installation, for which waivers do not exist, should immediately be brought to the attention of the engineer. 4. Ensure that all materials being used are in compliance with the most current guidelines established by the Municipality of Anchorage. This includes, but is not limited to, the following: a. Draiurock b. Sand filter material for conventional beds, trenches, or mound systems. c. Sand filter material and pea gravel for Intermittent Sand Filters (ISF). d. Anchorage Sand and Gravel (AS&G) "block pea" material for Upflow Filters. It is reconunended that the contractor provide the engineer with current sieve analysis' from the sand/gravel supplier to document the suitability of the material. The engineer assumes no responsibility for ensuring that the materials delivered meet the MOA requirements. 5. The coutractor shall ensure that the septic tank, lift station, or holding tank purchased has a burial depth rating suitable for the actual installation. 6. Notify the engineer at least 24 hours prior to starting construction. If deemed necessary, a preconstmction site visit shall take place. The contractor shall coordinate with the engineer any inspections which will be required during weekends, holidays, or before/after normal working hours (8:00 am to 5:00 PM). The property owner may incur additional charges for inspections which do not occur during normal business hours. It is the contractor's responsibility to notify the engineer a least 2 hours prior to any inspection. 7. The contractor shall report to the engineer any observed condition which would put the septic system in violation of State or Municipal regulat/ons. 2 of 4 AVVI/VC, Inc., September 1999 8. Any remaining test hole excavations shall be filled and mounded. Unless instructed otherwise by the engineer, the old test hole groundwater monitoring pipes shall be removed. 9. The contractor is responsible for final grading so as to ensure that surface runoff does not adversely effect the septic system constructed, adjacent septic systems, or adjacent structures. 10. The contractor is responsible for obtaining approval from the property owner for any additional construction costs associated with design modifications or changing field conditions, prior to doing the · Engineer Responsibilities: 1. The engineer is responsible for inspecting the installation of the septic system and preparing as-built documentation, to the satisfaction of the M.O.A.. Inspections are performed as necessary to document the construction of the system to the satisfaction of the M.O.A. In all cases, the following inspections shall be performed: * The bottom of all trench/bed excavation * Top of sand on all sand filters * Top of drainpipe * Septic tank, or lift station, or holding tank prior to backfill * Placement of filter fabric and insulation * After f'mal grading is completed Additional inspections may be required depending on the construction methods used by the contractor and the type of system being installed. 2. The inspecting engineer has no direct authority over the contractors activities or construction practices. Should the engineer identify conditions which dictate a design change, he or she may recommend that work be stopped,, and/or the design be modified. If design modifications are necessary, the engineer shall notify the property owner or his/her representative. 3. The engineer shall inspect the condition of the existing septic tank and determining its suitability for re-use. If the engineer determines the septic tank to be stmcturally unsound, it must be replaced. IV. CONSTRUCTION GUIDELINES: · General Construction shall be in accordance with the approved site plan and design drawings, and any special provisions noted on the municipal well and/or sewer permit. All materials, components, and construction practices shall comply with the Municipality of Anchorage's latest ordinances regarding wells and septic systems, as well as DHHS policies. The failure of the inspecting engineer to notice a material or construction non-compliance does not relieve the contractor of his/her responsibility to correct such a deficiency. · Septic Tank, Holding Tank, or Lift Station Installation: 1. ~l~e burial rating of the tank shall be adequate for the actual burial depth encountered. 2. The tank shall be level and sufficiently bedded to prevent settling or shifting of the tank. 3. All standpipes on the tank shall extend a minimum of 12 inches above final grade. 4. Tanks installed with less than 4 feet of cover shall be insulated. 3 of 4 AWWC, Inc., September 1999 5. The sewer service line from the house to the tank shall be sloped a minimum of 1/4" per foot, unless prior approval is obtained from the engineer. 6. ~l~e inlet and outlet lines from the tank shall be bedded in drahu-ock or the soil shall be adequately compacted to prevent future settlement of the soil. 7. A foundation clean-out will be installed, 1-4 feet from the house, if one does not currently exist. 8. Post tank clean-outs shall be installed per MOA requirements. Does not apply to holding tanks or lift stations with pressurized lines. 9. Ail tanks shall be anchored to resist buoyancy forces in high groundwater areas. This applies when there is not adequate soil cover to resist buoyancy forces. Engineer shall make this detertnination. 10. The fmal soil cover shall be graded so that there is positive drainage away from tank. 11. All holding tanks and lift stations shall have an audible and visible alarm inside the residence. 12. All lift stations shall be wired in compliance with all MOA guidelines and the Uniform Electrical Code. 13. The contractor shall remove the old tank, or abandon it in compliance with the Uniform Plumbing Code (UPC). The contractor is solely responsible for the abandonment procedure. · Installation of Conventional Absorption Bed & Trenches: 1. Excavate the proposed bed/trench to the dknensions shown on the design. The bottom of the excavation shall be within 2 inches of level (2 inch max/mum variation between high and low spots). If the sidewalls or bottom of the excavation become smeared, they must be raked or scarified before placement of the filter sand or draimock. 2. The trench or bed should be at least 5 feet from the test hole excavation. 3. All soil tests and excavation depths are advisory to the design and are to be verified in the field by the engineer. If design changes are necessary, and the changes effect the contractor charges to the property owner, the contractor shall obtain approval from the properly owner prior to proceeding with the work. 4. Once the drainrock is installed, the distribution pipe is to be placed level (0.02 feet difference between high and low shots) with the perforations faced downward. Drainrock is then to be placed over the distribution pipe, to provide a minimum of 2 inches of cover over the pipe. The drainrock shall not be pyramided over the drainpipe but shall be the same elevation over the entire trench/bed width. 5. A silt barrier must be installed between the f'mal draimock layer and the native soil backfill. The silt barrier shall cover the entire drainrock surface. 6. Monitor tubes shall be installed at the locations shown on the design drawings, and extend a minimum of 12 inches above f'mal grade. The portion of the monitoring tube extending through the drainrock shall be perforated from the bottom of the trench/bed to the invert of the distribution pipe. 7. Backfill over the fmal drainrock layer must not be less than 2 feet. Insulation must be installed when the backfill depth is less than 3 feet. The insulation shall cover the entire width of the trench/bed, the contractor shall "shoot" the f'mal grades to ensure cover depth is adequate, prior to notifying the engineer that the work is complete. The f'mal cover over the drainfield must graded so that there is no potential for water to pond over the trench/drainfield. 4 of 4 00/29/99 WED 09:21 FAX 907 §63 3516 A Fax from Dynamic Properties Phone (907) 261-7600 Fax (907) 261-7670 Fax~: % ~--/~'5~o Date: From: l~001 Reference: Total pages including cover eheet: I I II Message:_ If you did not receive all pages, please notify us at once. Thank You 3111 C Street, Suite I00, Anchorage. AK 99503 · Phone (907) 261-7600 Fax (907) 26117670 Parcel I.D. 018-173-22 Municipality of Anchorage On -Site Water and Wastewater Program (907) 343-7904 Certificate of On -Site Systems Approval 1. GENERAL INFORMATION: Expiration Date:�-- Complete legal description ELMORE #2; BLOCK 9, LOT 10 Location (site address) 4351 East 147th Avenue *Anchorage Current Property owner(s) James & Dianna Blakley Day phone 561-0826 Mailing address Real Estate Agent 2. TYPE OF DWELLING: ® Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) Day phone 3. NUMBER OF BEDROOMS: 3 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well ® Individual Individual Water Storage ❑ Holding Tank ❑ Community Class_Well ❑ Community ❑ Public Water System ❑ Public Sewer ❑ WaiverNariance request for: Distance: Received by: Date: COSA to be released to the engineer, unless otherwise requested by the engineer. COSA Fee $ Waiver Fee $ Date of Payment Date of Payment Receipt Number Receipt Number COSA #OS C 2 2C�3 5 Waiver # 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, - based on -procedures outlined in -the -Certificate of On -Site. Systems Approval Guidelines for this.-application,.- shows his..application, _shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm: Garness Engineerinq Group, Ltd (GEG) Phone: 907-337-6179 Address: 3701 East Tudor Road, Suite 101- Anchorage, Alaska 99507 Engineer's Printed Name: Jeffrey A. Garness Date: ZC, I ZZ_ Inconducting this evaluation, GEG provided an engineering evaluation of the well and/or septic system in accordance with the guidelines and regulations established by the Municipality of Anchorage and 0,�, 041 industry practices. The reported results describe the condition of the system/s on the date/s of the evaluation. Separation distances were measured to readily identifiable features. Hidden defects or OF G • . • • •' ' . . �l encroachments may exist that were not identified during the evaluation. The operational life of all wells / and septic systems depend upon a variety of variables, including but not limited to, soil conditions, . �I groundwater levels that may fluctuate during the ear g ( y g year), quality of construction (materials and workmanship), and the water usage of the family utilizing the system/s. These conditions can vary, and � t.: , .* ; ....... are outside the control of GEG. Satisfactory test results do not guarantee future performance of the 'r system/s; therefore, GEG makes no warranty (express or implied) regarding the future performance of the well or septic system. GEG makes no representation whether an alternative well or septic system ��� J- I .r _y H. rn ess. can be installed on the property in the event either of the current systems fail to perform adequately in (1� �. '•• CE 7a the future. The content of this report is for the sole benefit of the person/party that retained GEG to 2, 2 Glc perform the evaluation. Reliance upon the information provided in this report by any other person or d - ... 1-� 41UC party (including subsequent property purchasers) is not authorized, nor will it confer any legal right �oressl���� `���c'�� J whatsoever. 6. DSD SIGNATURE System #1 Approved for -3 bedrooms System #2 Approved for Disapproved Conditional approval for bedrooms bedrooms, with the fol #AECC884 Original Certificate Date: (�,9— 36 ^Z> The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist Septic System Advisory Well Flow Advisory Nitrate Advisory Arsenic Advisory Other -S`t-ee, ( F fvct t) t 761, 0,�, 041 -9 F T� g Qr'�'s9yO _ m 00' Original Certificate Date: (�,9— 36 ^Z> The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist Septic System Advisory Well Flow Advisory Nitrate Advisory Arsenic Advisory Other -S`t-ee, ( F fvct t) t 761, Legal Description: ELMORE #2; BLOCK 9, LOT 10 If more than 1 septic system on lot: COSA Checklist # of A. WELL DATA ❑ Well log is filed with Onsite (or attached) Date drilled 1973(?) Total depth *44.9+ ft Cased to UNKNOWN ft ❑ Sanitary seal is functioning correctly ❑ Wires are properly protected Casing height (above ground) 12+ in. Date of flow test for COSA 8/16/22 Static water level at beginning of test 26.6 ft. Comments *PER GEG INSPECTION B. TANK DATA Age of tank(s) 23 years Tank type/material SEPTIC/STEEL Measured operating fluid level in septic tank 52" ❑ Standpipes/foundation cleanout per record drawing Date of pumping 8/17/21 D. ABSORPTION FIELD DATA BED Which system tested (date installed) 9/23/99 ❑ ALL standpipes present per record drawing Total measured depth from grade &•0 ft (max) Measured depth to pipe invert from grade *2.83 ft (min) ❑ N/A — pressurized field ❑ Monitor tubes go to bottom of effective. If not, state depth into effective Parcel ID: 018-173-22 Structure served by this system Well production at time of test 7.2+ qpm Water storage tank volume N/A gallons Well disinfected for coliform test? ❑ Yes ❑ Nc ❑ Coliform bacteria is Negative Nitrate 1.00 mg/L ❑ Nitrate less than MRL (ND) Arsenic ug/L ❑ Arsenic less than MRL (ND) Collected by GEG, LTD Date of Sample 8/15/22 i£ 8/16/22 C. LIFT STATION ❑ Required maintenance completed Age of lift station ye Lift station material Commen MT1/MT2 Adequacy test date 8/16/22 Results ❑✓ Pass For 3 bedrooms Fluid depth prior to test 0/0 in Water added 787 gal New depth 0/1 in Elapsed time 15 min ❑ Code -required soil cover over field Final fluid depth 0/0 in ❑ System presoaked Absorption rate 450+ aDd (Required if vacant for greater than 30 days prior to Any rejuvenation treatment (past 12 months) N/A date of test) NONE Gallons introduced N/A gallons If yes, enter date Comments/Deficiencies:*BED IS INSULATED - MT1 EXTENDS 6" BELOW INVERT AND MT2 EXTENDS 33" BELOW INVERT (INTO SAND FILTER). - PRIOR TO (AND DURING) TEST BOTH MTS EXTENDED TO THE BOTTOM OF SAND. . AFTER TEST, MT1 WAS FILLED WITH SAND TO WITHIN 6" OF INVERT. PERFORATIONS IN MT1 EXTENDS UP INTO THE DRAINROCK. COSA Checklist yellow sheet 0 E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well) Septic Tank/Lift Station on Lot > 100' ❑ Yes if No Community Sewer Manhole/Cleanout > 100' R1 Yes if No ft � Yes if No ft Neighboring Tank > 100' Yes if No ft Private Sewer/Septic Line > 25' M Yes if No ft Absorption Field on Lot > 100' Cj Yes if No ft Holding Tank > 100' 0 Yes if No ft Neighboring Absorption Fields > 100' if No ft Animal Containment > 50' Q Yes if No ft 0 Yes if No ft ft If septic tank is under driveway comment below Manure/Animal Excreta Storage > 100' Community Sewer Main > 75' RYes if No ft r-11 Yes if No ft From Septic/Holding Tank on Lot to: (Please enter distances if less than required) Building Foundations > 10' ❑ Yes if No *5'+ ft Surface Water > 100' ❑✓ Yes if No ft Property Line > 5' Q Yes if No ft Wells on Adjacent Lots: Private Wells > 100' [] Yes if No ft Absorption Field > 5' (l Yes if No ft Private Wells > 100'[]✓ Yes if No ft Water Main > 10' P11 Yes if No ft Community Wells > 200' Yes if No ft Water Service Line > 10' M-1 Yes if No ft If septic tank is under driveway comment below From Absorption Field on Lot to: (Please enter distances if less than required) Building Foundation > 10' Q Yes if No ft If absorption field is under driveway comment below Property Line > 10' 0 Yes if No ft Wells on Adjacent Lots: Water Main > 10' Yes if No ft Private Wells > 100' [] Yes if No ft Water Service Line > 10' Yes if No ft Community Wells > 200' Yes if No ft Surface Water > 100' [1 Yes if No ft F. ENGINEER'S COMMENTS *MET CODE AT TIME OF INSTALL - ST1 IS 5.33' AWAY FROM DECK POST (SEE ATTACHED PHOTO) G. ENGINEER'S CERTIFICATION PT.. I certify that I have determined through Held inspections and review of Municipal records that the above systems are in conformance with p i MOA COSA guidelines in effect on this date. * q. .. f G ness., Q 9,- CE -7153., COSA Checklist yellow sheet P of esslon #AECC884 www.muni.org/onsite Septic 'Tank Advisory Certificate of On -Site Systems Approval #OSC221435 Subdivision: Elmore #2 Block 9 lot 10 Starting at 20 years of age the MOA issues Advisory's for steel septic tanks The septic tank for this COSA / property is 23 years old. A leaking septic tank may be a source of contamination to the aquifer. Typical replacement costs range from $10,000 to $15,000 This advisory must be attached to all copies of the subject Certificate of On -Site Systems Approval. This is an example of a 16 -year-old septic tank in failure and should be replaced. Mailing Address P O B6k'196650,-*-" 40, Alaska 99519-6650' * www muni org D�7 ]I S\� . • L7- ami 5 0 0 •* low .01 O O• N (n •� CD m m �yJ® 0 D v•8 1 cn ,� °mn N r c �N co4 =y?o p M LA 9, �mm° K m D V m m m ' o sG. •Cj mss_ 0 m c ®yob • �� y m ° m m Or < _ Q y — W m 3 c g o N m O m „�.. .O y On gtea, -n t—D = ID ,m�'?cv n z m gvo p a� 0 �' °cmonW Qua m C m m r+Q! m e y c. � v I'D O O O /r cD -< cn Q W m �1 •c == v = i -•o to -1 d" H m Z n y �-m O ��S N W °��go o0 iD rnD C m 2 2•c m m 3 -6, m Z= c 7 n p mCCD 0 CDy< m= M((o��c H v iTti. m 3 y oID f n 7 n N r �, y N= 0 S m y n = O °om r V,n rTj a ��m �y m 3��on C7 = 7 °mo W� om a m ° m ° co D g=n�ti �S �' c NOQ 0,0W 0 W O m K M C M O y n 7. O. N (n < r, c °a ca m nD Nr? =oyc�so w 0 ETN y m s 3Wo t W r0 0' 03 0- to N .�• <• m = 40 C �. 11On Nr V_1 • r < y g CD /... N m O' n N 7 N r 00 m O• y' 7' 01 O N S O. 7 Ey O .�. 51 y 6 t0 7 y 7 D) D ° F.a.a _ a d y 0 m N D7 p Q y m ` 0 7 a' = m r O1 y C N a =° m m m Q om m 0d (A 3 y CD m O y m °" 7 m Q3 N fD O < 0mCD- 3 F; h m 3 CD0 CD CD III 3 r m ICY) • y a 1 D 1 I e 1W I ` m a AVAigA a 9'C.9 LOT 11 n n S00° 07'00'E 190.00 10' UTIL. ESMT• I O1 1D N rr CD ° co o o w cn r I o I m r+ w �o!nNQ� I CL I afA QZ�� o •�•�} Ti ti.Q ? O ` G I (D wD v�n��� \ CD "'• ,t- NC' moc 0- co I y S ( A CA)1 cn ° W V •' 24.2 ( COVERED , n STORAGE II I a 24.2' s s9 x z I O . N y m w I `£l 24.2 I'A COc I 38.3 rn �yz x) 8.9 I rn 38.3 71 °' 9.6Z v O I I r+ m o \ \% FQ 'A y I N v• N NO 0* 190.00 g p IA) LOT Municipality o.f AnChorage Development Services Department Building Safety Division On-Site Water & Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 Parcel I.D. 018-173-22 1. GENERAL INFORMATION CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING HA,,,,,,. 14 A Expiration Date: 'o '200 d_,¢ -/3-03 Completelegaldescription -ELMORE SUBDIVISION #2; LOT 10, BLOCK 9 Location (site address or directions) . 4351 EAST 147TH * ANCHORAGEt AK 99516 Current Property owner(s) Mailing address Lending agency Mailing address Real Estate Agent Mailing address ROBERT & PATRICIA SClANDRA Day phone 344-3473 4351 EAST 147TH * ANCHORAGEt AK 99516 Day phone JERRY DEWHURST w/ REMAX PROPERTIES Day phone 2600 CORDOVA * ANCHORAGE, AK 99503 257-0113 Unless otherwise requested, HAA will be held by DSD for pickup. 2. NUMBER OF BEDROOMS: 3 3. TYPE OF WATER SUPPLY: Individual Well ~ Individual Water Storage Community Class Well ~___ Public Water System TYPE OF WASTEWATER DISPOSAL: Individual On-site Individual Holding tank Community On-site Public Sewer The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of Health Authority Approval (HAA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of Health Authority Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues HAAs upon request to homeowners. Certificates of Health Authority Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water samples. (Cedificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. INote: Alaska Water and Wastewater Consultants, Inc. shall be paid $ at, or pfior I to closing for the engineering services provided. I 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I vedfy that my investigation, based on procedures outlined in the Health Authority Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is(are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I furfher verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm ALASKA WATER & WASTEWATER CONSULTANTS, INC. Address 6901 DEBARR ROAD, SUITE 2B * ANCHORAGE, AK 99504 Engineer's Printed Name JEFFREY A. GARNESS, P.E. Engineer's Comments: In conducting this evaluation, AKWWC, Inc. attempted to provide a thorough, conscientious engineering analysis of the system in accordance with ADEC and MOA DSD Guidelines & Regulations. The reported results descfibed the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readily identifiable features. The operational life of all wells and septic systems depend on the local soils condition, groundwater levels that may fluctuate during the year, and the water usage of the family being se/red by the system. These conditions are outside the control of the evaluator of the system. Satisfactory test results do not guarantee future performance of the system, nor do they guarantee that there are no hidden defects or encroachments. AKWWC, Inc. can therefore not provide any warranty or future estimate of how long the system will continue to meet the operational requirements of the ADEC or MOA DSD. The content of this report is for the sole benefit of the owner listed above. Any reliance upon or use of this report by any other person or party is not authorized, nor will it confer any legal fight whatsoever. Phone 357-6179 Date DSD SIGNATURE ^pprove ,or bedrooms. Disapproved. Conditional approval for bedrooms, with the fllowing stipulations: ?E WATER AHD ,'. F OG M. Attachments: HAA Checklist Septic System Advisory Well Flow Advisory Manitenance Agreements Supplemental Engineer's Reort Other Original Certificate Date: Municipality of Anchorage Development Services: Department BUilding Safety Division on.Site water & Wastewater,Program 4700 South 8ragaw SL P;O?O0x 196650.Anchorage, AKOg519-6650 .. www.cLanchorage.ak.us (907) ~43-7904 Legal:0es~r~P~0n: A. WEEL :DATA, HEALTH AUTHORITY APPROVAL CHECKLIST ELMORE SUBDMSION f2;,, LOT 10, BLOCK 9 Parcel ID:, *PER lg73 INSPECTION REPORT Well:tyPe- ,PRIVAI~ ,, If A. 8~ or C,prevlde PWSID~ N/A, Well Log (Y/N) 0ate completed P~0R 10 e/-/3 Sanitary seal (Y/N), YES Totaldepth *65=~fL Cased to 40+,,. fL FROM WELL LOG Oata of test Statiowater level ~ .... g,p.m. WATER SAMPLE RESULTS: Coliform , ~,, colones/100ml. Arsenic: N/'A, mg./L. B; SEPTIC/HOLDING TANK DATA Tank Type/Material ....... · -.~ , , , Tank size, :! 000 ~ ,gal. Number of Compartments 2, FoundaUoncleanout (Y/N) YES, Depression over tank (Y/N) NO, Cate of putllp!lng 2/7/2003 .... Pumper C, ABSORPTION.FIELD.DATA Datei~stalle~,~,e/ls"22/1999~ ~ . SoD rating ~r ft~/bdrm) 0.7 Total depth, .*5,e ,lt. Eft. abSOrptiOn, area 675 lt* MOnitoring tube YES Oate of adequacy test =,~.2/7,/2003,.. Results (Pass/Fall) PASS, Fluid depth:in.absorption fieldbefore, test, 0, in. Water added 706.gal. Elapsed Time: , 0 min. Finaltluld depth 0 in. Absorption rate >= Any rejuvenation treatment (past 12 mo.) (Y/N & type) NONE KNOWN 018-173-22 NO $~5+ O.P.m- wires properly protected (Y/N) Casing height (above ground) ~ 12+, AT INSPECTION 2/-//2oo · in. Nitrate J,:jj mg~. Otherbacterla (~ colonles/100ml. Date of sample: al C Co,lec ed - . AKWWC,.INC.. Date instaned ,, 0/'16/'1999 , Cleanouts (Y/N) YES High water alarm (Y/N) , N/'A DENAU PUMPIN(} Systemtype , BED ,, , Gravelbelowplpe T0'65 , fL Depression overfield NO For .'~, ,. bedrooms Newdepth ,0, in. 450+ , g.p.d. If yes, give data - D. LIFT STATION Date installed Size in gallons "Pump on' level at in. "Pump o.~.~_..[a~-'"'~, High water alarm level at in. ~ Cycles tested Meets alarm & circuit requirements?. E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot100'+ Absorption field on lot 100'+ Public sewer main N/A Sewer/septic service line 25'+ On adjacent lots 100'+ On adjacent lots 100'+ Public sewer manhole/cleanout N/A Holding tank N/A SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 5'+ Property line 5'+ Water main N/A Water service line 10'+ Wells on adjacent lots 100'+ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line 10'+ Water service line 10°+ Curtain drain NONE KNOWN F. COMMENTS Absorption field 5,+ Surface water. 100'+ Water main N/A Driveway. parking/vehicle storage Building foundation 10'+ Surface water t 00'+ Wells on adjacent lots 100'+ 10' + G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and review of Municipal records that the above systems ere in conformance with MOA I-IAA guidelines in effect on this date. Engineer's Printed Name JEFFREY A. GARNESS Date Of Payment Receipt Number Waiver Fee $ Date of Payment Receipt Number Il \ , .t 4-42 ?~olC I hereby certify that I have surveyed the following: described property: ........................................... Anchorage Recording Precinct. Alaska. and th;~t improvemenls situated Ihercon ;Pre within the propelly lines and do not overlap or oriel'ut*ch on th~' I)r~perly lying adjacent thereto, that no improvements on prop- erty lying adjacent thereto encroach on the prvmi'xex ~uestion and Ihat lhere ~ re no ro~dwavs, I 'ansmissio. lines or other vixible easements on as indicated hereon. Dated at Anchorage, Alaska FREi) WALATKA & ASSOCIATES Enxtneers and Surveyors MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & HUMAN SERVICES Division of Environmental Services On-Site Services Section P.O. Box 196650 Anchorage, Alaska 99519-6650 343-4744 Parcel I.D. # CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING 018-173-22 HAA# ~l~(~, Otc~ ~'')L~ ~ L'\ GENERALINFORMATION Lot 10; Complete'legaldescription Block 9; Elm0re Subdivision #2 Location (site address or directions) 4351 E. 147th Avenue Anchorage, AK Prope~yowner Rick Moody .Dayphone-345-1999 Mailingaddr~ss 4351 E. 147th Ave. Anchoraqe, AK 99516 L'ending agency Day phone Mailing address Agent Address Day phone Unless otherwise requested, HAA will be held for pickup. NUMBER OF BEDROOMS: 3 TYPE OF WATER SUPPLY: NOTE: TYPE OF WASTEWATER DISPOSAL: NOTE: xx Individual well Community well Public water If community well system, provide written confirmation from State ADEC attest- ing to the legality and status of system. Individual on-site XX Holding tank Community on-site Public sewer If community wastewater system, provide written confirmation from State ADEC attesting to the legality and status of system. 724)25 (Re~. 1/'91) Front MOA 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my~seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health Authority Approval application shows that the on-site water supply and/or wastewater disposal system is safe functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in com ~liance with all Municipal and State codes, ordinances, and regulations in effect on the date of inspection. Name ~)f Firm Address Engineer's signature F~ Alaska Water & Wastewater COnsultants, Inc. Shall be PAID ,$~, ~/..~' ~ at, or prior to, closing for the Engineering Services Provided. Phone Date ~l~ ?/./~ 6. DHHS SIGNATURE ~" Approved for ~/-//~EE bedrooms. Disapproved. Conditional approval for bedrooms, with the following stipulations: Additional comments By: The Municipality of Anchorage Department of 'Health and Human Services (DHHS) issues Health Authority Approval-~;ertificates based only upon the representations given in paragraph 5 above by an independent professional en gin eer registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHHS do not conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. RECEIVFD Municipality of Anchorage 8EP 27 1<)90 DEPARTMENT OF HEALTH & HUMAN SERVI~t~{~mAUT Environmental Services Division 825 L Street, Room 502 · Anchorage, Alaska 99501 · (907) 343-4744 Health Authority Approval Checklist Legal Description: ELMORE S/D #2; LT 10, BK 9 Parcel I.D.: 018-175-22 A. WELL DATA * PER 1975 INSPECTION REPORT. Well type PRIVATE Log present (Y/N) Total depth '65' Sanitary seal (Y/N) Date of test Static water level Well production WATER SAMPLE RESULTS: If A, B, or C, attach ADEC letter. ADEC water system number N/A NO Date completed PRIOR TO 8/73 Cased to 40'+ Casing height (above ground) 15" **YES Wires properly protected (WN) **YF.~ ** BEING REPAIRED FROM WELL LOG AT INSPECTION BY HOMEOWNER 52 g.p.m. 5.65 g.p.m. Coliform 0 Nitrate Date of sample: 9/g/99 - 9/12/99 B. SEPTIC/HOLDING TANK DATA Date installed 9/16/99 Foundation cleanout (WN) Date of Pumping NEW C. ABSORPTION FIELD DATA Date installed 9/16/99 Length 45' Width Effective absorption area 675 SQ FT Date of adequacy test NEW O.8B4 mg/L Other bacteria 0 Collected by: A.W,W.C., INC. Tank size 1000 YES Depression (Y/N) NO Pumper - High water alarm (Y/N) Number of Compartments 2 Cleanouts (Y/N)YES N/A *** 2'-5" OF M.O.A. SAND FILTER ADDED BELOW TOTAL DEPTH. Soil rating (g.p.d./fF or ft2/bdrm) 0.7 System type BED 15' Gravel thickness below pipe 0.65' Total depth Monitoring Tube present (Y/N)~5_. Depression over field (Y/N) NO · Results (Pass/Fail) PASS For 3 bedrooms Fluid depth in absorption field before test (in.); I~er aaaea gnJ: Fluid depth (i~ Absorption rate = g.p.d. _--P-er~atment (past 12 months) (Y/N) If yes, give date 72-026 (Rev. 3/96)* Date installed_ _ ~ ................ Manhole/Access (Y/N) ~~f~.' level at* "Pump off" level at- ~igh water~ *Datum. E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic/holding tank on lot Absorption field on lot Public sewer main Sewer/septic service line 100'+ 100% 25'+ 100'+ On adjacent lots On adjacent lots 100'+ Public sewer manhole/cleanout Lift station N/A SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Foundation 5'+ Property line 5'+ Water main/service line 10'+ Sudace water/drainage 100'+ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOTTO: Property line 10'+ Building foundation 1 O' Absorption field Wells on adjacent lots 5'+ 100% Water main/service line 10'+ Sudace water 100'+ Curtain drain NONE (NOWN F. ENGINEER'S CERTIFIOAT,~O~/ I certify that I,~ d~ 'n~fnf/~ thr ~ld inspections inconforma~ce~ty/~ ~L linesineffectonthisdate. Engineer's Nan~e ! , JEFFREY A. GARNESS Date ~' j//~'/ ~'~ Driveway, parking/vehicle storage area 10'+ 100'+ Wells on adjacent lots HAA Fee $ c~ Date of Payment Receipt Number 72-026 (Rev. 3/96)* Waiver Fee $ Date of Payment Receipt Number