ON-SITE WASTEWATER INSPECTION REPORT
Permit Number: OSP141253 PID Number: 015-051-18 ❑ New ❑✓ Upgrade
Name:
RICKY THOMPSON
ABSORPTION FIELD
❑✓ Deep Trench ❑ Shallow Trench ❑ Bed ❑ Mound
Address
9361 STRUTZ AVE
❑ Other
Phone
Number of Bedrooms
Soil Rating
Total depth from original grade
4
0.6GPD/SF
12 Ft,
LEGAL DESCRIPTION
Depth to pipe invert from original grade
3 Ft.
Gravel depth beneath pipe
9Ft.
Subdivision Block Lot
COHOE 6
Fill added above original grade
0.5 Ft.
Gravel length
60 Ft.
Township Range Section
Gravel width
3Ft.
Beds: Number of Lines
Distance between lines
Ft.
SEPARATION DISTANCES
To
Septic
Absorption
Holding
Sewer
Total absorption area
Number of trenches
Dist. between trenches
From
Tank
Field
Lift Station
Tank
Line
108OFel
Fl
18 Ft.
Well
205.7+
104.7
205.7
N/A
N/A
TANK ❑ Septic Z S.T.E.P. ❑ Holding ❑ Other
Manufacturer
ANCHORAGE TANK
Capacity
1250Gal.
Surface Water
100+
100+
100+
N/A
Material
Number of compartments
Lot Line
28.4
17.5
28.4
N/A
STEEL
2
NA
Foundation
12.5+
20.9
12.5
N/A
LIFT STATION
Manufacturer
Capacity
Curtain Drain
N/A
I N/A
I N/A
N/A
ORENCO
250 Gal.
RemarksCONTINUOUS LINE FROM LIFT STATION TO
Pump on level at
40in.
Pump off level at
36in.
High water alarm at
45 in.
TEE. LINE INSULATED UNDER DRIVEWAY.
Pump make and model
P2005-1
Electrical Inspections performed by
7) e 6/', "tt
Installer
PIPE MATERIAL Housetotank Tankto
drainfeld 3034
A -PLUS HOME SERVICES
Drainfield 3034 CO/MT 3034
Inspector PANNONE ENGINEERING SERVICES
BENCH MARK (Assumed elevation) 100111
Inspection 1e'7121/2014
dates: 2" a 7/22/2014
Location and description
V 7/23/2014 0
HOUSE FINISHED FLOOR
COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL
Engineers Stamp
Conditional Approval: Date
3�C3F !4L1
. �,�►����
y,,,r�P�
PIP
..tateven { onnorae
Approved Date 7-12-
w
`r ' .►
Inspection Report_1-1 .doc IV
COHOE L
T
A I B I
C
E
DC01 22.401 13.80
EASEMENT
DCO2 22.90 13.20
T1 26.10 14.60
0F3
T2 34.00 22.30
MH 35.50 24.00
M1
22
45.20
M2
44.70
62.50
M3 61.60
40.90
64.80
M4
58.10
79.60
3
10A
0
W
W/
, �/
,W G
APPROXIMATE LOCATION OF
WATER SERVICE LINE (E)
MAINTAINAI0' HORIZONTAL SEPARATION TO DRAIN FIELD ,
AND 36 -INCHES VERTICAL SEPARATION MT.
FROM PRESSURE DISTRIBUTION LINE/
&—M
UPGRADED SEPTIC SYSTEM
(2EA) 3OLF x 3'W x 9.0'ED x 12.0'TD _ e
>MT4 y
A
\SEPTIC AREA (E)V 1 TH-1
17
104.7 _
WELL (E)'
NOTES:
RECORD DRAWING
PLAN
134.4
PANNONE ENG
P.O. BOX 100217 ANCHOR)
PHONE (907) 272-8218 FAX
• , ' DRIVEWAY
\ LO 6
10,
MIN \
JG 1250g SEPTIC TANK REMOVED
1500 GAL S.T.E.P TANK
L-.
SEPTIC AREA (E)
SEPTIC AREA (E) 1
rIII +I
J DRAIN FIELD (E)
�,-�..,,� IN FAILURE
SHED 11 REUSE AS RESERb
<v 9
r
2`�> E
MT2
10' UTILITY
EASEMENT
10' U� EASEMENT
\PIPE CAPPED
\I SEPTIC AREA (E)
I z z)
w•w
MP r!
J I ffi b
LLC
272-8211
COHOE, LOT 6
RICKY THOMPSON
9361 Z AVENUE
ANCHORAGE, v
AK 99507
Date
OF ACq�I� 7/24/2014
.s9il� Scale
•*��P.I.D. NO
015-051-16
n • Pannorie� PERMIT N0.
CE 8149 OSP141253
���� ���' Sheet
"� 2
0F3
Date
OF ACq�I� 7/24/2014
.s9il� Scale
•*��P.I.D. NO
015-051-16
n • Pannorie� PERMIT N0.
CE 8149 OSP141253
���� ���' Sheet
"� 2
SPECIAL PROVISIONS TO SPECIFICATIONS
1. ALL CONSTRUCTION SHALL WAS INSTALLED AS SPECIFIED IN THE MOST CURRENT EDITION OF THE MUNICIPALITY OF
ANCHORAGE STANDARD SPECIFICATIONS (MASS) FOR COMPONENT PARTS AND MATERIALS USED IN CONSTRUCTION OF
ON-SITE WASTEWATER DISPOSAL SYSTEMS.
3. SCOPE OF WORK: REPLACED EXISTING 1250 GAL SEPTIC TANK WITH 1500 GAL TANK, INSTALLED NEW 500g LIFT
STATION. AND INSTALLED SOIL ABSORPTION SYSTEM.
4. GROUNDWATER WAS NOT ENCOUNTERED TO A DEPTH OF 18 FEET BELOW EXISTING GRADE AS EVIDENCED BY THE SOIL
TEST HOLE. AN APPARENT WATER TABLE WAS NOT OBSERVED IN ANY OF THE EXCAVATIONS LESS THAN 18 FEET.
FILTER FABRIC3.0 Id
_c. l_9'7S'r..
36 -INCHES
MIN
TER SERVICE .DRAIN ROCK
10' 10'
1 Y4" 0 PERF PIPE W/ 74" HOLES
DRILLED 18" O.C.
3 DRAIN ROCK 6" ABOVE PIPE INV
1F— 3
1 1
S (� 93.58
)�3
TH-1
DIP
-0.5 OR (W) 96.53-
TH
(W) 93.5
FC
GM/
T#
SM
C#
(W) 84.5
M#
-16.0
r
RIGID INSULATION
wo
DOUBLE CLEAN OUT
mz
0
o
OU
z
BFG
BELOW FINISH GRADE
3.
�
89.18
RIGID INSULATION
3
6.0
1500 g S.T.E.P
3.0
TANK (E)
PROFILE
FILTER FABRIC3.0 Id
_c. l_9'7S'r..
36 -INCHES
MIN
TER SERVICE .DRAIN ROCK
10' 10'
1 Y4" 0 PERF PIPE W/ 74" HOLES
DRILLED 18" O.C.
3 DRAIN ROCK 6" ABOVE PIPE INV
1F— 3
1 1
S (� 93.58
)�3
LEGEND
W WATERLINE/
WELL RADIUS
— SS — NEW SEPTIC
NOTES:
RECORD DRAWINGS I
DESIGN DETAILS
DESIGN PARAMETERS
RESERVE SEPTIC SYSTEM
NO. BEDROOM: 4 (600 gpd)
TANK SIZE: 1500g S.T.E.P.
PERC RATE = 29.4 MPI
SOIL RATING: 0.6 GPD/SF
AREA RQD: 1000 SF
SYS. TYPE: DEEP TRENCH WED
MIN LENGTH: 55.6 LF
USE:
(2EA) 30LF x 3'W x 9.0'ED x 12.0'TD
TOTAL AREA: 1,080 SF
PANNONE ENG SVC, LLC
P.O. BOX 100217 ANCHORAGE, AK 99510
PHONE (907) 272-8218 FAX (907) 272-8211
COHOE, LOT 6
RICKY THOMPSON
9361 STRUTZ AVENUE
ANCHORAGE, AK 99507
CU
COPPER
DIP
DUCTILE IRON PIPE
TH
TEST HOLE
FC
FOUNDATION CLEAN OUT
T#
TANK CLEAN OUT NO.
C#
CLEAN OUT NO.
M#
MONITOR TUBE NO.
R. 1.
RIGID INSULATION
DCO
DOUBLE CLEAN OUT
DV
DIVERTER VALVE
FS
9'0
BFG
BELOW FINISH GRADE
OG
�
FG
DRAIN ROCK
3
6.0
18.0—I
3.0
(E) 84.58
SECTION
w
m
z
FILTER FABRIC
w
o
x
1 Ya" 0 PERF PIPE W/Ya° HOLES
�
F
z
�
DRILLED 18` O.C.
DRAIN ROCK 6" ABOVE PIPE INV
5
2"RIGID INSULATION
UNDER DRIVEWAY
� ;�#
LEGEND
W WATERLINE/
WELL RADIUS
— SS — NEW SEPTIC
NOTES:
RECORD DRAWINGS I
DESIGN DETAILS
DESIGN PARAMETERS
RESERVE SEPTIC SYSTEM
NO. BEDROOM: 4 (600 gpd)
TANK SIZE: 1500g S.T.E.P.
PERC RATE = 29.4 MPI
SOIL RATING: 0.6 GPD/SF
AREA RQD: 1000 SF
SYS. TYPE: DEEP TRENCH WED
MIN LENGTH: 55.6 LF
USE:
(2EA) 30LF x 3'W x 9.0'ED x 12.0'TD
TOTAL AREA: 1,080 SF
PANNONE ENG SVC, LLC
P.O. BOX 100217 ANCHORAGE, AK 99510
PHONE (907) 272-8218 FAX (907) 272-8211
COHOE, LOT 6
RICKY THOMPSON
9361 STRUTZ AVENUE
ANCHORAGE, AK 99507
CU
COPPER
DIP
DUCTILE IRON PIPE
TH
TEST HOLE
FC
FOUNDATION CLEAN OUT
T#
TANK CLEAN OUT NO.
C#
CLEAN OUT NO.
M#
MONITOR TUBE NO.
R. 1.
RIGID INSULATION
DCO
DOUBLE CLEAN OUT
DV
DIVERTER VALVE
FS
FLOW SPLITTER
BFG
BELOW FINISH GRADE
OG
ORIGINAL GRADE
FG
FINISH GRADE
TS&V
TOPSOIL & VEGETATE
ate
bF ^lq,kil 177/24/2014
* ••:*I, NTS
.... ... .. ...,. �. .I.D. NO
015-051-18
•StevenR. •Pannone• PERMIT N0.
�P,n •. CE 8149 .•,Eta „�,,, ,,.,�,
3 OF
Municipality of Anchorage
Community° Development Department
Development Services Division
P.O. Box 196650 - 4700 Elmore Road
Anchorage, Alasla 99519-6650
Info and Help: (907) 343-8211
INSPECTION:
Voice: (907) 343-8300 Fax (907) 249-7777
Inspection Report
7/24/2014
License/AP--: RETROE141372
Parent AN
Inspection #:
311406
Type:
RETRO
Status:
Issued
Address: 9361 STRUTZ AVE
Parcel: 01505118000
Inspector: Mike Green
Project:
Resp Party:
Desc: Retro6tunrp Power controls san lift sta hp Me -
Address:Anchorage, AK, 99507
Inspection Item Item Description Evaluation
Originally Cited Code
Description
Electrical Electrical Inspection Approved
Result Notes: Septic electrical rough, underground and final.
On -Site Wastewater Disposal System Permit
MUNICIPALITY OF ANCHORAGE
Development Services Department
On -Site Water & Wastewater Program
4700 Elmore Road, PO Box 196650
Anchorage, AK 99519-6650
Telephone: (907) 343-7904
Permit Number: OSP141253
Tax Code Number: 01505118000
Work Type: Septic Upgrade
Permit Effective Dates: July 17, 2014 to July 17, 2015
Design Engineer: PANNONE ENGINEERING SERVICE
Subdivision: COHOE
Site Legal Address: COHOE LT 6 G:2437
Owner/Address: THOMPSON RICKY R &
VANDERWERF MARY H 9361 STRUTZ AVE ANCHORAGE AK 995074349
Site Mailing Address: 9361 STRUTZ AVE, Anchorage Lot Size in Sq Ft: 19000
Total Bedrooms: 4
This permit is for the construction of:
Y Disposal Field Y Septic Tank N Holding Tank N Privy N Private Well N Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater
Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80).
3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services
Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either:
A. Open and Close on the same day.
B. Covered, sealed, and heated to prevent freezing.
Received
Issued By
By: Date: { r ol v
Date:
MUNICIPALITY OF ANCHORAGE
Community Development Department Phone: 907-343-7904
Development Services Division Fax: 907-343-7997
On -Site Water & Wastewater Program
RUSH
ON-SITE SEWER/WELL PERMIT APPLICATION
Parcel I.D. 015-051-18
RUSH
Property owner(s) Ricky Thompson & Mary Vanderwerf Day phone
Mailing address 9361 Strutz Avenue, Anchorage, AK 99507
Site address 9361 Strutz Avenue
Legal description (Sub'd., Block & Lot) Cohoe, Lot 6
Legal description (Township, Range & Section)
Lot Size 19,000 Sq. Ft. Number of Bedrooms 4
RUSx
APPLICATION IS FOR: APPLICATION IS AN:
TYPE OF DWELLING:
(® all that apply)
Single Family
❑X
Absorption Field FX] Initial ❑
(SF)
(w/wo ADU)
Septic Tank ❑X Upgrade ❑X
Duplex (D)
❑
Holding Tank ❑ Ree I _
in Al
Mu(SFaltiple Dnd/olrinDjs
❑
Privy ❑ S�,%I'IT
Private Well ❑ JUL 1 6 2014
Water Storage ❑
__
RUSH
THIS APPLICATION INCLUDES A VARIANCE! WAIVER REQUEST FOR:
RUSH
Distance:
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
(Signature of property owner or authorized agent)
Permit/Rush Fees: I �.�a ' 0110,40 Waiver Fees:
Date of Payment: l n t4 Date of Payment:
Receipt Number: 0CA92A Receipt Number:
Permit No. OWN 2-5.3 Waiver No. _
RUSH 1�
Permit App_' :L.,",R y SH
RUSH
Pannone Engineering Services uc
Steven R. Pannone, Principal
Registered Professional Engineer
E-mail: steve(coanengak.com
July 16, 2014
Municipality of Anchorage
Development Services Department
On -Site Water & Wastewater Program
4700 Elmore Road
P. O. Box 196650
Anchorage, Alaska 99519
Subject: Cohoe, Lot 6
Septic System Upgrade Permit Request
Ladies and Gentlemen:
I am writing to request a permit to install a new septic system be issued for this property. The proposed
systems will serve a existing four (4) bedroom house. Currently the existing field is in failure. The existing
1250G septic tank will be decommissioned per code and a 1250g S.T.E.P. tank will be installed. This lot is
served by a Class'A' water system. The surrounding lots to the north and west are served by this same
water system. There are no Class 'A'wells within 200' of this system. The lots to the east and south are
served by private wells. There are no private wells within 100' of this system.
Soils. PES performed one test hole on this lot in July of 2014, and groundwater was monitored for seven
days. Ground water was NOT observed below the ground elevation in the test hole monitor tube. It is my
opinion, based on the results of the soils tests, the use of a conventional system and overall soils
appearance; an application rate of 0.6 gallons/day/square feet should be used for a conventional
wastewater system.
1. Soil Absorption System Design.
a. See Sheet 2 of the design package.
2. Surface Water: There is no surface water within 100 feet of the proposed septic tank and drain
field. The proposed drain field upgrade will maintain at least 100 feet from all surface water and drainage
ditches.
3. Topography: The proposed drain field is located on the flat top of a knoll. The surrounding
topography radiates away from the field from 5% to the east to 20% to the northwest and south. There
are no steep slopes in the vicinity.
Mailing: P.O. Box 100217, Anchorage, AK 99510-0217
Physical: 332 East Manor, Anchorage, AK 99501
Telephone: (907) 272-8218 FAX: (907) 272-8211
Page 2 of 2
4. Drawing Markings: The Drawings are marked "For MoA Review Only". When written notification
that the review is complete and that there are no further comments is received from MoA On -Site
Department, the note will be removed and "Issued for Construction" drawings will be issued.
The proposed installation will not affect the future development of the surrounding or existing lots.
If you have any questions or concerns, please contact me at 272-8218.
Sincerely,
Steven R. Pannone, P.E.
Owner/Civil Engineer
Mailing: P.O. Box 100217, Anchorage, AK 99510-0217
Physical: 332 East Manor Ave, Anchorage, AK 99501
Telephone: (907) 272-8218 FAX: (907) 272-8211
i
Q
OHSD V
w �
z
a W VJ, SEPTIC AREA (E)
SEPTIC AREA (E)
VERIFIED 1250g SEPTIC TANK (E)
ON 7/17/14 DRAIN FIELD (E)
ADD 500g LIFT STATION (P) IN FAILURE
APPROXIMATE LOCATION OF ��y STIED REUSE AS RESERVE
WATER SERVICE LINE (E) DRIVEWAY SHED
10' HORIZONTAL SEPARATION TO DRAIN FIELD I
AND 36 -INCHES VERTICAL SEPARATION kk, S PTIC AREA (E)
FROM PRESSURE DISTRIBUTION LINE _-_
DRAIN FIELD (P)
(2EA) 30LF x 3'W x 9.0'ED x 12. 'TD ' �Q'
a LII
o o
M yy �)
M
SEPTIC AREA (E)� . TH-1 I —
' 19.1 7 10' UTILITY EASEMENT
10
7UTILITY EAST ,
108.2 EMENT
�- WELL (E)
\I
�� ��� uate
NOTES: PANNONE ENG SVC, LLC SOFA/,., � 7/17/2014
FOR CONSTRUCTION P.O. BOX 100217 ANCHORAGE, AK 99510 r '� .S
PHONE (907) 272-8218 FAX (907) 272-8211 /g�p �yt) scale
*, TH 1•=50•
�... .. .. . ...... P.I.D. NO
COHOE, LOT 6 / / 015-051-18
RICKY THOMPSON / Steven R. Pannone PERMIT NO.
PF.•, CE 8149 OSP141253
9361 STRUTZ AVENUE+�s. r
PLAN ANCHORAGE, AK 99507 �il� PROFES sheet
t��ROFES 1 OF 3
SPECIAL PROVISIONS TO SPECIFICATIONS
1. ALL CONSTRUCTION SHALL BE INSTALLED AS SPECIFIED IN THE MOST CURRENT EDITION OF THE MUNICIPALITY OF
ANCHORAGE STANDARD SPECIFICATIONS (MASS) FOR COMPONENT PARTS AND MATERIALS USED IN CONSTRUCTION OF
ON—SITE WASTEWATER DISPOSAL SYSTEMS.
3. SCOPE OF WORK: INSTALL NEW 500g LIFT STATION. INSTALL SOIL ABSORPTION SYSTEM.
4. GROUNDWATER WAS NOT ENCOUNTERED TO A DEPTH OF 18 FEET BELOW EXISTING GRADE AS EVIDENCED BY THE SOIL
TEST HOLE. IF AN APPARENT WATER TABLE IS OBSERVED IN ANY OF THE EXCAVATIONS LESS THAN 18 FEET BELOW
EXISTING GRADE NOTIFY THE ENGINEER IMMEDIATELY.
TH-1
'ILTER FABRIC
1 Ya" 0 PERF PIPE W1 IV HOLES
DRILLED 1 B" O.C.
-DRAIN ROCK 6" ABOVE PIPE INV
1250 g SEPTIC I �; �5
TANK(E) WATER
10' 10'
PROFILE
SECTION
8.0
M
FILTER FABRIC
o,
o
o f
1 Yn" 0 PERF PIPE W/)6" HOLES
a o
z
TEST HOLE
DRILLED 18" O.C.
fff
zz
D iS
u
z�
m a
DRAIN ROCK 6" ABOVE PIPE INV
20
11
A
11
1250 g SEPTIC I �; �5
TANK(E) WATER
10' 10'
PROFILE
CU
COPPER
DESIGN PARAMETERS
DIP
DUCTILE IRON PIPE
RESERVE SEPTIC SYSTEM
TH
TEST HOLE
LEGEND
NO. BEDROOM: 4 (600 gpd)
FC
FOUNDATION CLEAN OUT
W WATER LINE/
TANK SIZE: 12508 S.T.E.P.
T#
TANK CLEAN OUT NO.
WELL RADIUS
PERC RATE = 29.4 MPI
C#
CLEAN OUT N0.
SOIL RATING: 0.6 GPD/SF
M#
MONITOR TUBE NO.
AREA ROD: 1000 SF
SS NEW SEPTIC
SYS. TYPE: DEEP TRENCH 9'ED
R.I.
RIGID INSULATION
MIN LENGTH: 55.6 LF
DCO
DOUBLE CLEAN OUT
DV
DIVERTER VALVE
USE:
FS
FLOW SPLITTER
(2EA) 3OLF x 3'W x 9.0'ED x 12.0'TD
BFG
BELOW FINISH GRADE
TOTAL AREA: 1,080 SF
OG
ORIGINAL GRADE
FG
FINISH GRADE
TS&V
TOPSOIL & VEGETATE
NOTES:
FOR CONSTRUCTION
DESIGN DETAILS
PANNONE ENG SVC, LLC
P.O. BOX 100217 ANCHORAGE, AK 99510
PHONE (907) 272-8218 FAX (907) 272-8211
COHOE, LOT 6
RICKY THOMPSON
9361 STRUTZ AVENUE
ANCHORAGE, AK 99507
OF A4;jk1, 17/17/2014
*.,.�TH l�►T :*��/ P.. D.T
INO
l�V % 015-051-18
Steve e � PERMIT NO.
CE 8149 OSP141253
Sheet2 OF 3
SOILS LOG - PERCOLATION TEST
TEST HOLE 1
OR ORGANICS SLOPE \N ,NJ SI DRIVEWAY SHED
SHED
2LO 6
3—
4—
6X
aJ
TH
7
8 TH-
GM/ SANDY 10' UTILITY . EASEMENT
10 SIM GRAVEL WITH ry�10 UTILITY EASEMENT
SOME SILT
12 77
13
WAS GROUND WATER SLOPE
14 ENCOUNTERED? N
15 IF YES, AT WHAT TH
16 DEPTH? DRY X
17 DEPTH TO WATER AFTER
MONITORING? DRY
18 DATE: 7/16/2014 1
BOH
19 CLOCK WATER
READING DATE TIME NET TIME LEVEL NET DROP
20 READING
1 7/9/2014 10:50 - 5.72
2 11:20 30 MIN 6.75 1.03
DATE PERFORMED: 7/9/14 3 11:20 - 5.72 -
4 11:50 30 MIN 6.74 1.02
5 11:60 5.72 -
6 12:20 30 MIN 6.74 1.02
PEROLATION RATE 29.4 (min/inch) PERO HOLE DIAMETER 6 inches
TEST RUN BETWEEN 4 FT AND 5 FT
COMMENTS: Test hole excavated by A+ HOME SERVICES. Perc hole was presoaked. Test was run for at least
one hour. Last three readings reported.
PERFORMED BY: Steven R. Pannone, P.E. I CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE
WITH ALL STATE AND MUNICIPAL GUIDLINES IN EFFECT ON THE DATE OF THIS TEST.
NOTES: I& Date
PAMONE ENG SVC, LLC /1 7/17/2014
FOR CONSTRUCTION P.O. BOX 100217 ANCHORAGE, AK 99510 ............ 4
Scale
PHONE (907) 272-8218 FAX (907) 272-8211
NTS
... ... ... P.I.D. NO
COHOE, LOT 6 015-051-18
RICKY THOMPSON meven R. annone _R
CE 8149 /PERMIT NO
9361 STRUTZ AVENUE az OSP141253
Sheet
SOILS LOG ANCHORAGE, AK 99507 iN � - -,
k)ll 3 OF 3
Register 163, July 2002 ENVIRONMENTAL CONSERVATION
(A) the site of the proposed system is remote from a community with
access to professional engineering services; and that the resulting cost of bringing a
registered engineer to the site would be overly burdensome; and
(B) public health, public and private water systems, and the environment
are adequately protected without this requirement,
(2) justify the lesser distance and explain how the lesser distance does not
threaten public health, public and private water systems, or the environment;
(3) describe soil classifications, groundwater conditions, surface topography,
geology, and other environmental conditions that would assist the department in establishing a
lesser separation distance; and
(4) include a set of plans, consisting of
(A) record drawings if the department determines them necessary to
evaluate the request;
(B) an accurate description, including the location, of potential sources of
contamination, surface water, groundwater, and existing or potential drinking water
sources in the area; and
(C) the details of the system design that
(i) address the physical and environmental conditions in (3) of this
subsection; and
(ii) will prevent contamination of the surface water, groundwater,
or drinking water sources identified in (B) of this paragraph at the lesser distance;
and
(D) other information the department determines to be necessary to assess
the effect of a lesser distance upon public health, public and private water systems, and
the environment.
(f) In accordance with 18 AAC 72.060, the department will approve a waiver of the
separation distance required by (b) or (c) of this section if the department finds, after review of
the report submitted under (e) of this section, that a lesser separation distance does not threaten
public health or the environment and protects surface water, groundwater, and existing or
potential drinking water sources. As necessary to protect public health and the environment, and
to protect surface water, groundwater, and existing or potential drinking water sources, the
department will require changes to system design as a condition of approval, including increased
depth of grout and changes to the pipe material, pipe bedding, joints, and pipe strength.
(g) A person may not install
0
Register 163, July 2002 ENVIRONMENTAL CONSERVATION
(1) a septic tank or soil absorption system directly above or below a water line at
any distance, or within 10 horizontal feet of a water line; or
(2) a sewer line directly above or below at any distance, or within 10 horizontal
feet of a water line, unless
(A) the required location or separation distance cannot be met because of
the site configuration, the system design, or the presence of other obstacles that have
regulated separation distance requirements;
(B) the sewer line is designed and constructed in a manner equivalent to
the requirements for a potable water pipe, and
(i) is pressure tested to ensure watertightness; or
(ii) is enclosed in a carrier pipe of similar strength and rating as
the actual pipe, or of a strength and rating approved by the department as
protective of public health, public and private water systems; and the
environment;
(C) the sewer line is in a separate trench from the water line; and
(D) at locations where sewer and water lines must cross,
(i) the sewer line is installed below the water line to the maximum
length possible until existing appurtenances, elevations, or depth -of -cover
requirements prohibit such installation;
(ii) the sewer line uses a bedding that is specially designed to
protect the integrity of the sewer line in places where the elevation of a water line
is below a sewer line;
joints; and
(iii) the sewer line joints are at least nine feet from the water line
(iv) the sewer line is at least 18 vertical inches from a water line.
(h) Upon determining that a waiver will not threaten public health, public and private
water systems, or the environment, the department will waive the requirements of (g) of this
section in accordance with 18 AAC 72.060
(1) for a utilidor, if the water line is above the sewer line, and
(A) for an above -ground utilidor, the utilidor will not flood if pipe failure
occurs; or
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND HUMAN SERVICES
Environmental Health Division
825 "L" Street, Anchorage, Alaska 99502, Telephone 264-4720 0
ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
Name % DISTANCES
SEPTIC ABSORPTION
Address FROM TANK FIELD WELL
WELL r� f
Phones) Permit No. No. of Bedrooms -Gc % Z�Q
-3447970,035 !
LEGAL RIPTIGN 7 LOT LINE ,��' � i c71
Lot Block Subd��i rr++� iio�on,,
CEJ FOUNDATION zoo
Township, Range, Section
/� ����, r AS -BUILT DIAGRAM (Show location of well, septic system, property lines, foundation,
7ZZIL&/� 7 driveway, water bodies, etc.)
T KS a D ,I� - x �� _ .fit
SEPTIC ❑ HOLDING
I4' r t
41
Manufacturer Capacity in gallons
(Jf 2 5Q
Mat rial/��7o. of Compartments
L
Ar 1 $.3
TYPE af SYSTEM
TRENCH ❑ BED ❑ W. DRAIN ❑ OTHER
Depth to pipe bottom from
original grade
FT
Total depth from original grade
FT
Fill added above original grade
0__/ FT
Gravel depth beneath ipe
f FT
Gravel length
�� FT
Gravel width
r/ FT
Total absorption area
• f 419— SOFT
Distance between lines
/UIA FT
Number of lines
Soil rating 0
IFT
/25�Q
Pipe material f
! l (fs
Installer
Dale Installed Q
2 G49
WELLS
❑ PRIVATE ❑ OTHER (Identiliv)
Classification (A,B,C)
Installer Aat
Total Depth Cased to
FT FT
I tall d:
REMARKS:
ra t � � Scale: c•
AUS 9 eiuo r n yin ep. - kirt lo.Pi�l, �►'Fi�rn ections Pel
Date:
117-1 a0
I N certi( that this inspection was performed according to all
Municipal and State guidelines in effect on this date: L t �� /A
Health Department Approval: Date:
— V71 / A 0
-013 (3/13b)
It
a
I
IENGIVlE€R'S SEAL
MUNICIPALITY OF ANCHORAGE
Department of Health & Human Services
825 L Street, Anchorage, Alaska 99501 343-4720
ON-SITE SEWER PERMIT
Permit Number: 900357 Upgrade
Date Issued: 11/02/90 Engineer Designed
Owner Name:
LLOYD BELLAMY
Day Phone:
Owner Address:
9361 STRUTZ AVENUE
279-8866
ANCHORAGE, AK 99507
Parcel Id:
015-051-18
Lot Legal:
Subdivision: COHOE SUBDIVISION
Lot: 6
Block: -
Section: 15 Township: 12N
Range: 3W
Lot Size
19000 (sq.{t. or acres}
Max Bedrooms:
This Permit: 4 Total
Capacity: 4
`
SEPTIC TANK: Minimum
total septic tank
capacity: 1,250
gallons. Each septic
tank must have
at least 2 compartments.
Depth to top
of septic tank(s) < 4.0
feet requires
insulation over tank(s),,
TIKE PERMIT EXPIRES 12/31/90 AND VALID FOR A SINGLE FAMILY HOME.
CONSIRUCT PER ENGINEER'S ATTACHED DESIGN.
lNFORM D.H.H"S° A MINIMUM OF 2 HOURS PRIOR TO INSPECTIONS BY
ENGINEER, IF AFTER OFFICE HOURS, CALL 343-4681 AND LEAVE A
MESSAGE.
I CERTIFY THAT:
1. I am familiar with the requirements for on-site sewers and wells as set
forth by the Municipality of Anchorage (MOA) and the State of Alaska.
2. I will install the system in accordance with all MOA codes and regulations,
and in compliance with the design criteria of this permit.
J. I will adhere to all MOA and State of Alaska requirements {or the set back
distances from any existing well, wastewater disposal system or public
sewerage on thi or any adjacent or nearby lot.
4. I understanc AM 3ormit is valid for a maximum of 4 bedrooms. I
also unde that capacity of the total system is 4 bedrooms and
j&,wiljAeiquire an additional permit,,
Signed:
Issued By:
VC
AMY
TE:
WASTEWATER NARRATIVE FOR LOT 6, COME SUBDIVISION
The location of the wastewater disposal system on the subject
property should have no negative affects to the adjacent
properties or the environment for the following reasons:
WELLS
There are no adjoining wells and the community well for this
property is properly separated from the planned wastewater
extension by at least 300 ft.
WASTEWATER SYSTEM
The wastewater system proposed for this property has been
located so that there will be no effects to any surrounding
properties. All setback distances have been satisfied as
required. Further the soils are of such a nature that
treatment will be assured over a long term period.
RESERVED SPACE
The wastewater system on this property have no effect in taking
away reserve area set aside on other adjacent lots.
SURFACE AND SUBSURFACE DRAINAGE
The wastewater system will have no impact to surface water
drainage due to the location and the fact that the contours
will remain unchanged. Subsurface drainage will be unaffected
since treatment of wastewater is assured before it reaches
groundwater tables.
M -
. ���Wtla
1
�� 1.5P,wer
Sewer✓' !�'S�
� I
Loi`
fJnVew S{►e�
E1u3{.125 uc�n1,—�°
.o,
'T,µ,*2
r---- 4,
Mem i f6ir
Slop4a.(e.a to°6f
2, esqj
d Q Dc Art
5%SLP
7 g /ver
te�� Flat- ��
cawc�-�
�1-1 rim k /SO = l000 / Z
�o 0,8 1�z 751
75'�z �2, Y `ldf
r -117
2-07-6
r8o � Lc2�r�t
fi �dtSu�ei�td-t ��t�6i7�
Q
,Okn eixt;t4. lh sbw Ave Cll—lwm tot� 0
11 �/L
4 ! Se,Ctf2% �t`G�t elr�✓ S' J'7�pdr�
r7
NOTE:
All Dimensions And Locations Must Be Field Verified Prior To Construction
SEWER. SYSTEM •LOCATION -PLAN
e
E1 x�X' C 56 YdsCI
,.
's",
SECTION/TOWHSI HtP/RAN
SCALE$ >%c/
�. DRAWN BYx.
NORTH ;ems
avcwswwcv.. -
COiC
NOTES ;
The Accuracy OC Location OC Exisiting And
Proposed Property Corners, Wells, and Septic
Systems Indicated 16 -Not Exact. Dimensions
Indicated Have Seen Determined By Urc.Or Cloth
Tape and/or Municipal Records, And Hot By
Surveying Techniques
PREPARED FORo
ls���-ale Ger
DATE, jD/J/1 l SHEET OF
municipa(ity,of Anchorage
DEPARTMENT OF HEALTH & HUMAN SERI
825 "L" Street. Anchorage. Alaska 99502-0(
SOILS LOG — PERCOLATION T9
0 F or,: 1:546 6�
v C- f-, r- 0 R M, C
Township. Range. Section:
LEGAL 0CSCR(pT(0N:—,, SLOPE
oEPTH
2
3
4
5
6
7
10-
11
12-
13-
14-
is -
16,
17
18
19
20
COMMENTS
a W1, 5: � 0 � 15c1A f C silt' " -
5911,5114 5~ f /f
%vASGROUNDWATER
ENCOUNTIEREO?
IF YES, AT WHAT
0EPTI-l?
cept to W&r
fexa:toriau? ��Otic
C,!
V
cgv '"I
ORKED--,
SITE PLAN
0/ 1
1&e4e-r PERCOLATION RATE "3 (minuteviach) PERC HOLE DIAMETER --(92—
-7'
SE<f' �r'ftrzc�i
TEST RUN BETWEEN --- *9— FT AND FT
PERFORMED 8y:
ACCORDANCE WITH ALL STATE AND MUNICIPAL
72-008 (Rev. 41851
TIFY THAT THIS TEST AS PERFORMED IN
THIS DATE- DATE: . - � 2�, i �1 - -
4OPM
0/ 1
1&e4e-r PERCOLATION RATE "3 (minuteviach) PERC HOLE DIAMETER --(92—
-7'
SE<f' �r'ftrzc�i
TEST RUN BETWEEN --- *9— FT AND FT
PERFORMED 8y:
ACCORDANCE WITH ALL STATE AND MUNICIPAL
72-008 (Rev. 41851
TIFY THAT THIS TEST AS PERFORMED IN
THIS DATE- DATE: . - � 2�, i �1 - -
ocorwin
& associates,inc.
Consulting Engineers
1000 E. Dimond Blvd. • Suite 205 • Anchorage, Alaska 99515 • (907) 522.1311
PERCOLATION TEST DATA SHEET
DATE
CLIENT S1qA
ADDRESS l "� J
ZIP CODE
LEGAL DESCRIPTION
TOTAL DEPTH OF HOLE
J�4��FT. TO 7�g FTZONE TESTED
READING CLOCK NET TIME DEPTH NET DROP
TIME TO
DATUM
FINAL PERCOLATION RATE }/ '
(min./in. ) �`,""�°a� �►�,�,� ,
PERFORMED BY L
em F!' es+�t,mw'Ca v
JAA It "win
1.
s.
�"
,, aos,►w,r A' ,y 'tii
PERFORr,;EO FOR:
Municipality. of Anchorage
DEPARTMENT OF HEALTH & HUMAN SE
825 "(_" Street• Anchorage. Alaska 99502•
SOILS LOG PERCOLATION T
LEGAL OESCRIPTION: �/
(FEET)
v�-
2
3
l b
4
6
7i /
Township, Range. Section:
SLOPE
WAS GROUND WATER % fO
10 I I ENCOUNTERED?
S
L
11 IF YES, AT WHAT O
' DEPTH? E
12 �Li1
(A Ylxtct Atkr
13 F,,oaitxi 7 tktc
la I • � S��l� � _
Is -
16
s 16
17
18
19
PERCOLATION RATE _S.-3-3 (minutevj;icj PERC HOLE OIAMETER
/ TEST RUN BETWEEN -3 IFT AND FT
COMMENTS Of 7 //"
V&RTIFY THAT T H!q T WAS PERFORMED III
PERFORMED BY: I
/ i /ate
ACCORDANCE 1ALL ST T� NO MUNICIPAL GU(OELI NES IN EFFECT ON THIS DATE. DATE:
72-008 (Rev. 41 1
• -
�■��r�
PERCOLATION RATE _S.-3-3 (minutevj;icj PERC HOLE OIAMETER
/ TEST RUN BETWEEN -3 IFT AND FT
COMMENTS Of 7 //"
V&RTIFY THAT T H!q T WAS PERFORMED III
PERFORMED BY: I
/ i /ate
ACCORDANCE 1ALL ST T� NO MUNICIPAL GU(OELI NES IN EFFECT ON THIS DATE. DATE:
72-008 (Rev. 41 1
o O
& associates,inc.
Consulting Engineers c,
1000 E. Dimond Blvd. • Suite 205 • Anchorage, Alaska 99515 • (907) 522+1°a^•.� N�
''66 �IYEYy\iiK{n�,;;l.yi'.'CtF> i
PERCOLATION TEST DATA SHEET
CLIENT �jG�/�� �/%/f DATE C` D
ADDRESS LO 7L !Z1�
ZIP CODE
LEGAL DESCRIPTION Z
TOTAL DEPTH OF HOLE FT, r
ZONE TESTED FT. TO FT.
s�l�,r�7dr
READING
CLOCK
TIME
NET TIME
DEPTH
TO
DATUM
NET DROP
©. ¢i
2oXA
3 7
lj, Zc>
o,3c�
1444114
0
FINAL PERCOLATION RA
PERFORMED BY
(min./in. )
November3-�, 197J
�3i.)] StruLz Avenue
Aj"icnuragu,
SubjiccL: Lot 6, CjNoe SUL)divisi011
Dear -Ir. tialtio.
Tids office approv;-,u tkp: ins".-allai-Iloo uf a SLptic Lank oil au:jj'LCL r1'0-
pem-N. ho.qt!ver, wo crave 11c, ififorkiiation on Via appamnt installa-itioil of a
uct� lul.-�Lrs 1-0 yUU Oil JUj Uary I ail ' gdjh J ill 0-1�6)Lr,
aria. office 6 1 I �.a k --
ififorilatioil ol-I tiie outs tantifivj ienyiit. T;ie most recti 6 I!, LL Le r
was no is
In ord,�r to aliprovo Lyiu existin-j permit, we will require L,,,,u fullu,Anj.
R-Cuij)L for gravel lvacicfill.
i,,(cJpt for criij mati:rial.
GumpleLe dia-gram of so:page area.
for al I Ape used.
J) i ncuvar fc)jr (4) corners of a'UsorVJL-ium arLd dUvi,') to gravel bacrIflil.
J unL u L,,,� r .j
iii Lei, (lea} days fel liuilrig rLCCipL of Liiis
Failure:. L -o coiiply will r aril is in legal aCI.Jur'.
Sincerely,
Susan L. i0icki.,rson.
Sardtariaii
RECEIPT FOR CERTIFIED MAIL -3041
(plus
postage)
-
SENT TO
POSTMARK
OR DATE
i
STREET AND NO.
00
co
P.O., STATE AND ZIP CODE
OPTIONAL SERVICES FOR ADDITIONAL FEES
'
RETURN 1 • Shows to whom and date delivered ...........
With delivery to addressee only ............
15¢
65¢
RECEIPT 2. Shows to whom, date and where delivered ..
35¢
SERVICES With delivery to addressee only ............
85¢
--t[- -- -----
VER TO ADDRESSEE ONLY .....................................................
50d
Q
SPECIAL DELIVERY (extra fee required) ....................................
,
Z
PS Form3800 NO INSURANCE COVERAGE PROVIDED—
(See other side)
Apr. 1971 NOT FOR INTERNATIONAL MAIL
n GPO :1972
O - 480-T43
GREATER ANCHORAGE AREA BOROUGH
o .$ DEPARTMENT OF ENVIRONMENTAL QUALITY
3330 "C" STREET ANCHORAGE, ALASKA 99503
f TELEPHONE 274-4561
SEWAGE DISPOSAL SYSTEM - APPLICATION AND PERMIT
0
NAME OF APPLICANT
INSTALLATION LOCATION
LEGAL DESCRIPTION L"' I, /
INSTALLATION OF: SEPTIC TANK L/
TYPE AND SIZE OF FACILITY TO BE SERVED
FINANCED THROUGH
PERMIT NO.
%.3 � l 5 fdyfiz '41-0 17�� - %� 2
MAILING ADDRESS PHONE
r4 1c(7f
E PIT_ DRAIN FlEy OTHER
/ / --fes+' / / 7
TO BE INSTALLED BY
SOIL TEST RESULTS —~ ��YIO rtil NOTE: THIS PERMIT IS NOT VALID WITHOUT SOIL TEST
COMPLETION DATE_ ANTICIPATED
FINAL INSPECTION: 24 HOUR NOTICE REQUIRED. BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION BY THE
DEPARTMENT OF ENVIRONMENTAL QUALITY AUTHORITY WILL BE SUBJECT T/g PRfjSEC TION.
bi SCi // —/Ql'—e > h&Vfir/ i r/
SEPTIC TANK SIZE V TYPE ••�� SEEPAGE AREA S
MINIMUM DISTANCES, REQUIREMENTS
FOUNDATION TO SEPTIC TANK
FOUNDATION TO SEEPAGE PIT Z a DRAIN FIELD
SEPTIC TANK TO SEEPAGE PIT WALL —
SEPTIC TANK _ , SEEPAGE PIT
, DRAIN FIELD
TO NEAREST LOT LINE.
WELL TO SEPTIC TANK`o-1 0q�.e EPAGE PIT —.
DRAIN FIELD _ ALSO
CONSIDER AREA WELLS.
WATER MAIN TO SEPTIC TANK / tJ
SEEPAGE PIT
DRAIN FIELD� r0 --•
SEPTIC TANK, 11_111 SEEPAGE PIT .lam_.
DRAIN FIELD/D 0 f
TO RIVER, LAKE. STREAM.
CAST IRON INTO AND OUT OF SEPTIC TANK AND INTO CRIB CROSSING GAP OF
EXCAVATION 5 FEET INTO UNDISTURBED SOIL.
4 INCH DIAMETER CAST IRON SIPHON PIPES ON SEPTIC TANK AND SEEPAGE PIT
FITTED WITH AIRTIGHT REMOVABLE CAPS.
GRAVEL BACKFILL
CONFORM TO BOROUGH REGULATIONS REGARDING INSTALLATION.
7
r /✓
�.._.. G.A.A.B. U
OR
Z713LICENS D DESIGNER
To 0bf�t /)I
ERTIFY THAT I AM FAMILIAR WITH THE REQUIREMENTS OF GREATER ANCHORAGE
�PE
DIAGRAM OF SYSTEM
I G
DESCRIBED SYSTEM IS IN ACCORDANCE WITH SAID CODE.
DATE ) / 7 3 APPLICANT'S SIGNATURE
FORM NO. EQ -016
i
A
NAME OF APPLICANT _
GREA I ER ANCHORAGE AREA BOkJUGH
PARTMENT OF ENVIRONMENTAL QUALITY
3500 TUDOR ROAD POUCH 6-65-0
ANCHORAGE, ALASKA 99502
TELEPHONE 279-8686
AGE DISPOSAL SYSTEM — APPLICATION AND PERMIT
PERMIT NO.
j
4.I�C lel, II\raI%\ MAILING ADDRESS C, 3(C S`f IZIY G' ly�y - PHONE
INSTALLATION LOCATION :S - ^ Z--i4L)C
LEGAL DESCRIPTIONLi- G �'����t� �i�Vl
INSTALLATION OF: SEPTIC TANK SEEPAGE PIT DRAIN FIELD OTHER
TYPE AND SIZE OF FACILITY TO BE SERVED 3c'�'tz, 111.?; I ly�l -4 -- -
FINANCED THROUGH 7 {/ TO BE INSTALLED BY -7 E I F-"
f FL,
SOIL TEST RESULTS NOTES THIS PERMIT IS NOT VALID WITHOUT SOIL TEST
COMPLETION DATE ANTICIPATED
FINAL INSPECTION: 24 HOUR NOTICE REQUIRED. BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION BY THE
HEALTH DEPARTMENT AUTHORITY WILL BE SUBJECT TO PROSECUTION.
'
SEPTIC TANK SIZE � TYPE ��Y�\'t-L- �' S }tABEEPAGE AREA SIZE TYPE
MINIMUM DISTANCES, REQUIREMENTS DIAGRAM OF SYSTEM
FOUNDATION TO SEPTIC TANK
FOUNDATION TO SEEPAGE PIT
DRAIN FIELD
SEPTIC TANK TO SEEPAGE PIT WALL
SEPTIC TANK �r . SEEPAGE PIT �el / , DRAIN FIELD
TO NEAREST LOT LINE.
r
WELL TO SEPTIC TANK
DRAIN FIELD
WATER MAIN TO SEPTIC TANK
rte'
DRAIN FIELD
SEEPAGE PIT l6elcj
ALSO CONSIDER AREA WELLS.
f
—, SEEPAGE PIT /
10
SEPTIC TANK, G !) SEEPAGE PIT DRAIN FIELD ,
TO RIVER, LAKE, STREAM.
CAST IRON INTO AND OUT OF SEPTIC TANK AND INTO CRIB CROSSING GAP OF
EXCAVATION 5 FEET INTO UNDISTURBED SOIL.
4 INCH DIAMETE AST N SIPHON PIPES ON SEPTIC TANK AND SEEPAGE PIT
FITTED WITH AIRTIGHT REMOVABLE CAPS.
GRAVEL BACKFILL
CONFORM TO BOROUGH REGULATIONS REGARDING INSTALLATION.
HEALTH AUTHORIT
OR
LICENSED DESI ER
1 CERTIFY THAT I AM FAMILIAR WITH THE REQUIREMENTS OF GREATER ANCHORAGE AREA BOROUGH ORDINANCE NO. 28.68 AND THAT THE ABOVE
DESCRIBED SYSTEM IS IN ACCORDANCE WITH SAID CODE. -
DATE APPLICANT'S SIGNATURE
January 19, 1971
ldr. William Waldo
7800 iicBarr Road
Anchorage, Alaska 99504
SUBJECT: Permit and Application for Sewage Disposal
System, Lot G, Cohoe Subdivision
Uear Mr. Waldo:
August 10, 1970, you obtained a permit from this Department
for the installation of a sewage disposal system. As of
this date, the permit is still outstanding.
Please advise this Department if you have installed, or
still intend to install, a sewer system on the subject
property and wish your permit kept pending in our files.
Sincerely,
Lynn S. Coad
Sanitarian
rn
GARB -HD -2 GREATET 1NCHORAGE AREA )ROUGH Case No. g;
HEALTH DEPARTMENT
327 Eagle St. Anchorage, Alaska 99501 279-2511
SEWAGE DISPOSAL SYSTEM — APPLICATION & PERMIT
NAME OF APPLICANT % - �( '; t �� MAILING ADDRESS 79040 � �--PHONE NO�`3`__P40
RESIDENCE ADDRESS LOCATION OF INSTALLATION �%7�[.t 7?_
LEGAL DESCRIPTION ' ��
APPLICATION TO INSTALL: SEPTIC TANK , SEEPAGE PIT , DRAIN FIELD , OTHER
TO SERVE THE FOLLOWING FACILITY 11-D T 1
FINANCED THROUGH TO BE INSTALLED BY
PERCOLATION TEST RESULTS
ANTICIPATED DATE OF COMPLETIO ✓ Ivelf
BELOW TO BE FILLED OUT BY HEALTH DEPARTMENT
THIS IS TO SERVE AS �� ( PERMIT TO INSTALL A
AS DESCRIBED BELOW. SIZE ew
E SERVED��
. SEPTIC TANK SIZE UD TYPESEEPAGE AREA TYPE
DIAGRAM OF SYSTEM
DISTANCES:
I. d
C
HEALTH AUTHORITY I� I I 1 I 1 1 1 I 1 I IOR
I
LICENSED DESIGNER
I certify that I am familiar with the requirements of Greater Anchorage Area Borough Ord' ance No. 28-68 and that the
above described system is in accordance with said code. rI/©i'- f/©1 �/.P��!a+
DATE
G' �� !� APPLICANTS SIGNATURE-r"-�"`
I
Ell
3
&U,je,l ha -C 006 W -O, -K-
1
Ccrl+arl� W141. S0 eA Ma44*
C -am Oc-cup- ( rL
powlxrt�+,,or) 4�0$1
p,cA<e,ff, and I e--'!,
COVI(c,h WO oaf U-)MI,px
44le
ape
C'oMpOC_�4PA
and consir.6vii-
Water Encountered?_ Aa —.
-2��
— — - — --------------
170 140t t", cl pit
nlet
Of
lZM
...........
Test Performed
w
I
c
MUNICIPALITY OF ANCHORAG
Development Services Department`/ Phone: 907-343-7904
On -Site Water & Wastewater Section Fax: 907-343-7997
Certificate of On -Site Systems Approval
Parcel I.D. 015-051-18
Legal description COHOE LT 6
Site address 9361 STRUTZ AVE
Expiration Date:
Current property owner(s) CHRISTIE ERIKA & AARON REID
6/12/2025
X The On-site system(s) is/are approved for 4 bedrooms
Conditional approval for bedrooms, with the following stipulations:
Comments or advisories:
By: A% Original Certificate Date: 31-2-01-,7 1-1
This Certificate of On -Site Systems Approval (COSA) is intended to demonstrate the subject
system(s) is/are in substantial compliance with municipal code. The Municipality of
Anchorage, Development Services Department (DSD) issues COSAs based upon
representations provided by an independent professional engineer. The Municipality of
Anchorage is not responsible for errors or omissions in the professional engineer's work.
Fit Ifi[�:IiT [4V1t&113
COSA Checklist X Well Flow Advisory
Absorption Field Advisory Nitrate Advisory
Tank Age Advisory Arsenic Advisory
Other
COSA Approval_June 2022
III :: 1 p qi ;Iiri III III
Development Services Department
-
Phone: 907-343-7904
On -Site Water & Wastewater Section Fax: 907-343-7997
Certificate of On -Site Systems Approval Application
1. GENERAL INFORMATION
Parcel I.D. 015-051-18
Complete legal description COHOE LOT 6
Location (site address) 9361 STRUTZ AVENUE ANCHORAGE, AK 99507
Current property owner(s) CHRISTIE ERIKA & AARON REID - Day phone
2. ON-SITE SYSTEMS SIZED FOR 4 BEDROOMS
3. TYPE OF WATER SUPPLY: ❑ Private Well F-1 Private Well serving 2 dwelling units
R Private Well serving 3+ dwelling units Z Community Well or Public
F-1 Water Storage
4. TYPE OF WASTEWATER DISPOSAL: Z Private Septic F] Private Septic serving 2 dwelling units
[-I Holding Tank FI Community Septic or Public Sewer
5. SEPTIC TANK: Z Steel F1 Plastic F-1 Concrete F-1 Fiberglass
to
Age � - See advisory if steel older than 20 years
6. ABSORPTION FIELD: 0 AWWTS r_1 Bed H Deep Trench r_1 Wide Trench El Seepage Pit
Waiver request for:
Expedited review requested: ❑
Distance:
By applying for this entitlement, this property is subject to inspection by municipal On-site staff
to verify the accuracy of the information provided. I
COSA Fee $ 0
Date of Payment ai�t67
COSA# 0-c-2G2'41?_6J
Waiver Fee $
Date of Payment
Waiver #
COSA Application.doc
COSA Checklist.docx
COSA Checklist
Legal Description: COHOE LOT 6 Parcel ID: 015-051-18
If more than 1 well and/or septic system on lot, provide separate checklist. Structure served by this system ____
A. WELL DATA - PUBLIC &/OR CLASS “A” WATER
Well log is filed with Onsite (or attached)
Date drilled Total depth ft
Cased to ft
Sanitary seal is functioning correctly
Wires are properly protected
Casing height (above ground) in.
Date of flow test for COSA
Static water level at beginning of test ft.
Well production at time of test gpm
Water storage tank volume NA gallons
Well disinfected for coliform test? Yes No
Coliform bacteria is Negative
Nitrate mg/L Nitrate less than MRL (ND)
Arsenic ug/L Arsenic less than MRL (ND)
Collected by
Date
Comments __________________________________________________________________________________
B. TANK DATA
Measured operating fluid level in septic tank *NA
Date of pumping 6/12/24
Required maintenance completed, if AWWTS
Comments: *STEP FLOATS
C. LIFT STATION
Required maintenance completed
Age of lift station 10 years
Lift station material STEEL
Comments:
D. ABSORPTION FIELD DATA
Which system tested (date installed) 7/23/14
ALL standpipes present per record drawing
Total measured depth from grade 13.9 ft (max)
Measured depth to pipe invert from grade N/A ft (min)
N/A – pressurized field.
Per record drawings, field is insulated.
Monitor tubes (MT) go to bottom of effective (ED).
If not, state depth into effective
Presoaked required if
(Required if house vacant or field not used for more
than 30 days prior to date of test)
Gallons introduced gallons date
Any rejuvenation treatment (past 12 months) N
If yes, enter date
Adequacy test date 6/13/2024
Results Pass (North / South Trenches)
Fluid depth prior to test 31 / 20 in
Water added 650 gal
New fluid depth 47 / 33 in
Elapsed time 1440 min
Final fluid depth 31 / 20 in
Absorption rate 600 gpd
FIELD STATUS – POST RECOVERY
Effective depth (per record drawings) 108 in (MOA 9’ ED)
Effective depth used 31 / 20 in (Final Fluid Depth)
Effective depth remaining 77 / 88 in
Comments/Deficiencies: Approximate total measured depths from existing grade. ED per measured shots, visual
observations, MOA docs & appears approximate.
COSA Checklist.docx
E. SEPARATION DISTANCES
From Private Well on Lot to: (Please enter distances if less than required or if community well on lot) - NA
Septic Tank/Lift Station on Lot > 100’
Yes if No ft
Neighboring Tank > 100’ Yes if No ft
Absorption Field on Lot > 100’ Yes if No ft
Neighboring Absorption Fields > 100’
Yes if No ft
Community Sewer Main > 75’ Yes if No ft
Community Sewer Manhole/Cleanout > 100’
Yes if No ft
Private Sewer/Septic Line > 25’ Yes if No ft
Holding Tank > 100’ Yes if No ft
Animal Containment > 50’ Yes if No ft
Manure/Animal Excreta Storage > 100’
Yes if No ft
N/A – Served by Community Well (not on lot) or Public Water
From Septic/Holding Tank and Absorption Field(s) on Lot to: (Please enter distances if less than required)
Building Foundations > 10’ Yes if No ft
Tank to Property Line > 5’ Yes if No ft
Field to Property Line > 10’ Yes if No ft
Water Main > 10’ Yes if No ft
Water Service Line > 10’ Yes if No ft
Surface Water > 100’ Yes if No ft
Wells on Adjacent Lots:
Private Wells > 100’ Yes if No ft
Community Wells > 200’ Yes if No ft
If tank or field is under driveway comment below
F. ENGINEER’S COMMENTS
G. CERTIFICATION & STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based
on procedures outlined in the Certificate of On-Site Systems Approval Guidelines, indicates that the on-site water
supply and/or wastewater disposal system appears to comply with applicable Municipal and State codes,
ordinances, and regulations in effect at the time of installation, unless noted otherwise.
Name of Firm FIRST WATER CONSULTING Phone 907-350-9566
Engineer’s Printed Name CURTIS HUFFMAN, PE Date 7/12/2024
Comments: This investigation was completed in compliance with MOA guidelines, regulations,
and best industry practices / methods. The assessment of the condition of the well and septic
applies only to the conditions as of the day tested. The flow and absorption rates may change
due to subsurface conditions that may not be observed from the surface, changes in land use,
local soil characteristics, groundwater levels that may fluctuate during the year, quality of
construction (workmanship & materials), the water usage of the family being served by the
system and maintenance. The operational life of all well and septic systems are subject to
these various and dynamic characteristics and are outside the control of the evaluator of the
well and septic system. Therefore, any or NO estimate of how long a system will function satisfactory
for current or future occupants or guarantee that no unseen encroachments, deficiencies or
discrepancies exist can be given by First Water Consulting &
7/12/24
MUNICIPALITY OF ANCHORAGE
All
Development Services Department Phone: 907-343-7904
On -Site Water & Wastewater Section Fax: 907-343-7997
Owner
Septic Tank:
*Sludge level oinches
Lift station:
Lift Station/Pump Vault
Maintenance Log
Street Address 9361 Si r
-Pumping: required &no
,Pump basket cleaned es no
*Control floats cleaned <& no
-Operation satisfactory es no
Alarm System:
tZ'
-Pumping completed es no
-Effluent filter cleaned es no
-Proper float settings confirmed es no
��ry� .2y
*Dedicated electrical alarm circuit es no -Audible and visual alarm inside dwelling es o
-Alarm system operation satisfacto not satisfacto
Manhole Riser
,Groundwater intrusion at riser to tank connection es
,Ground water intrusion around pipe penetrations yes
&Manhole lid: Functions e no Insulated es no
Other
-Weep hole functional 40 no
Properly Secured es no
-All manufacturer required inspections and maintenance completed
Comments:
Qualified Maintenance Provider:
Technician 1,0-,c' ,��
Company
Signature
Date of mainteiiamce D L) ne
Date o iu,_!L �
pati H
• '� Municipality of Anchorage
On -Site Water and Wastewater Program
(907)343-7904
Certificate of On -Site Systems Approval
Parcel I.D. -� jS 0 -� 1 ] 8 Expiration Date: :z
1. GENERAL INFORMATION
Complete legal description COhoe, Lot 6
Location (site address) 9361 Strutz Ave.
Current Property owner(s) Ricky Thompson & Mary Vanderwerf Day phone
Mailing address 9361 Strutz Ave. Anchorage, AK 99507
Real Estate Agent Day phone
2. TYPE OF DWELLING:
El Single Family (w/wo ADU)
❑ Duplex
❑ Multiple Dwellings (Single Family and/or Duplex)
3. NUMBER OF BEDROOMS: 4
4. TYPE OF WATER SUPPLY:
TYPE OF WASTEWATER DISPOSAL:
Individual Well
❑
Individual F]
Individual Water Storage
❑
Holding Tank ❑
Community Class Well
❑
Community ❑
Public tnrater System m
El
Public Sewer j_1
u
WaiverNariance request for:
Received by,
Date. ,
COSA to be released to the engineer, unless otherwise requested by the engineer.
COSA Fee
Date of Payment
Receipt Number
CosA # _ ° S G- / q 13 ,*
Waiver Fee $ _
Date of Payment
Receipt Number,
Waiver #
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation,
based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application,
shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the information
obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water
supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes,
ordinances, and regulations in effect at the time of installation.
Name of Firm Pannone Engineering Services LLC Phone (907) 272-8218
Address P.O. Box 100217, Anchorage Ak. 99510
Engineer's Printed Name Steven R Pannone Date 7L12014
OF A(q�l�'9lrl
6. DSD SIGNATURE j *" ..
8� System #1 Approved for bedrooms t : Sleven
R. Pannone
System #2 Approved for bedrooms �� *�y . CE -8149N.
Disapproved
���
Conditional approval for bedrooms, with the following stipulations:
By: Original Certificate Date: :7 ' /
The u ici® ity of nchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only
upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality
of Anchorage is not responsible for errors or omissions in the professional engineer's work.
7. ATTACHMENTS:
COSA Checklist X Nitrate Advisory
Septic System Advisory Arsenic Advisory
Well Flow Advisory Other
COSA blue sheet r c
If more than 1 septic system is on the lot:
COSA Checklist # !_of 1
Structure served by this system +
Certificate of On -Site Systems Approval Checklist
Legal Description: COhOe, Lot 6 Parcel ID: 015-051-18
A. WELL DATA
Well type Public If A, B, or C provide PWSID # AWWU Well Log (Y/N)
Date completed Sanitary seal (Y/N)
Total depth ft. Cased to ft.
FROM WELL LOG
Date of test
Static water level ft.
Well production g.p.m.
WATER SAMPLE RESULTS:
Coliform colonies/100 mL Nitrate mg/L
Arsenic ug/L Date of sample:
B. SEPTIC/HOLDING TANK DATA
Tank Type/Material S•T•E•P/Steel
Tank size 1,500 gal. Number of Compartments 2
Foundation cleanout (Y/N) Y Depression over tank (YIN) N
Date of pumping New Pumper
Wires properly protected (Y/N)
Casing height (above ground) in.
AT INSPECTION
ft.
Collected by:
Date installed 7/23/2014
Cleanouts (Y/N) Y
High water alarm (Y/N) Y
C. ABSORPTION FIELD DATA
Date installed 7/23/2014 Soil rating (g.p.d./ft2 or ftz/bdrm) 0.6 GPD/SF System type Deep Trench
Length 60 ft. Width 3 ft. Gravel below pipe 9 ft.
Total depth 12 ft. Eff. absorption area 1080 ftZ Monitoring tube Y Depression over field N
Date of adequacy test New Results (Pass/Fail) PBSS For 4 bedrooms
Fluid depth in absorption field before test New in. Water added New gal. New depth NeW in.
Elapsed Time: New min. Final fluid depth New in. Absorption rate , 600+ g.p.d.
Any rejuvenation treatment (past 12 mo.) (Y/N & type) No If yes, give date
D. LIFT STATION
Date installed 7/23/2014
"Pump on" level at 40 in.
Datum Bottom of Tank
E. SEPARATION DISTANCES
WELL ON LOT TO:
Septic tank/lift station on lot
Absorption field on lot
Public sewer main
Sewer /septic service line
Size in gallons 500
"Pump off' level at 36 in.
Cycles tested New
Manhole/Access (YIN) Y
High water alarm level at 45
Meets alarm & circuit requirements? Yes
On adjacent lots
On adjacent lots
Public sewer manhole/cleanout
Holding tank
Animal containment areas Manure/animal excrete storage areas
SEPTIC/HOLDING TANK ON LOT TO
Building foundation 5+ Property line 5+ Absorption field 5+
Water main 10+ Water service line 10+ _ Surface water 100+
Wells on adjacent lots 200+
ABSORPTION FIELD ON LOT TO:
Property line 10+ Building foundation 10+
Water Service line 10+
Curtain drain 50+
F. COMMENTS
G. ENGINEER'S CERTIFICATION
Surface water 100+
Wells on adjacent lots 200+
I certify that 1 have determined through field inspections and
review of Municipal records that the above systems are in
conformance with MOA COSA guidelines in effect on this date.
Engineer's Printed Name Steven R. Pannone
Date 7(26/2014
COSA brown sheet 10-10-12.doc
Water main 10+
Driveway, parking/vehicle storage 110+
in.
25'
Found 5/8" Rebar
1' Below Ground Level
Wood Rail
Fence
3
O °
LOT 5 00
o
I-
b Lo
0
z
Lee Knrnbelni
No. 3143-S
uf
Riser Pipes
(TYp-)
10' Utility Easement
Wood Fence (Typ.)
LOT 11
LOT 7
33.0
o in i�
118.1
-�-
Bi—Level Wood
Wood
.2"
y>°
Uh.,�.
.4. '
Residence
Wood
alb
a
o
Fence
Asphalt Drive
(TYp-)
10.4'
3\
�
Lift - .
82
21.4'
Station
LOT 6
?y
moo.. Wood
Inspection
PVC
O•
I �.... Porch
Pipe
w
w
0
0
> M.
. ^o LOT 7
Concrete qs
:w
00
Wood Deck
Retaining
in
& Stairs
Wall 2�fjay
f
0
I
oa
Bi—Level Wood
Wood
y>°
Frame?�
Shed
Residence
Wood
alb
a
o
Fence
(TYp-)
3\
�
oa
82
?y
moo.. Wood
O•
I �.... Porch
167.07'
589'55'58"W
r,
LOT 12
N
I
I hereby certify that an accurate survey of the following described
property:
COHOE SUBDIVISION (70-169)
1� LOT 6
was made on July 29, 2014 and that the improvements
situated thereon are within the property lines and do not overlap or
encroach on the property lying adjacent thereto, that no
improvements on the property lying adjacent thereto encroach on
low the premises in question and that there are no roadways,
transmission lines or other visible easements on said property except
r as indicated hereon. Easements other than those shown on the
record plat may not appear on this drawing.
Anchorage Alaska, this 31st day of July 2014.
SCALE : 1 " = 20'
0' 10' 20' 40'